Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Supply erection, testing and commissioning of 1x20 watt 1220mm long fluorescent tube T-5 fittings directly on wall including necessary connections with 0.75 sqmm PVC copper flexible cable for connecting the tube with adjacent light point complete in all respects of engineer in charge of the work. Make Philips, Crompton, havells, bajaj, galaxy live. |
| 2 | Providing, fixing and transportation of toilet cubicles of size as per architectural drawing, Door Size - 600mm x 1785mm, Divider Height - 1820mm, Comprising of Nylon components:(1) Nylon Gravity hinges (Right/ Life)(2) Nylon Door Knob(3) Nylon Lockset with indicator(4) Nylon Adjustable leg(5) Aluminum U Channel(6) Aluminum toprail(7) Aluminum door stopper Channel(8) Screws and wall plugs(9) Water, Chemical, Heat, Bacteria, Fire, Impact and Scratch Resistant 12 mm T Line High Pressure Compact Laminate.The 12mm HPL to have a minimum density of 1350 kg/m3 with a warpage limit of .5% of its length. The Top Rail will be fixed end to end and all the mid and end pilasters will get fixed into it. The whole system will have Upto 150 mm clearance height to the floor. U Sections will be used for Board to Board Jointing and Board to Wall Fixing.Complete upto Satisfaction of engineer incharge |
| 3 | Providing and fixing lift car of 8 passengers capacity with speed 0.63 m/s and having 3 no. of stops/ entrances (G, 1, 2). Travel height is 10.8mHeadroom 4650 mmPit depth1300 mmShaft dimensions (W x D) 1850 mm x 1850 mmBuilding tolerance (-25 mm /plus 25 mm)Car dimensions (W x D x H) 1100 mm x 1300 mm x 2200 mmCar Door size (W x H) 800 mm x 2000 mmCar Door Type - Door center opening, 2 panelsShop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution.Make - Schindler, Otis, Kone, Johnson or equivalent All works complete upto satisfaction of engineer incharge. |
| 4 | Providing and fixing of steel work welded in built up sections/ framed work with angles, tees, flat iron, round iron and sheet iron for making trusses, girders, tands etc. including cutting, drilling rivetting, handling assembling and fixing including erection in position as per the design. Steel of make Jindal, Apollo or equivalent. All works upto satisfaction of engineer incharge. |
| 5 | Health Faucet-make Jaquar or equivalent as per satisfaction of Engineer in Charge |
| 6 | 12watt recessed ceiling light make Philips,Crompton,bajaj,havells. |
| 7 | 15W LED Cove Light-make Philips,Crompton,bajaj, etc. as per satisfaction of Engineer in Charge |
| 8 | Supply, installation, testing, and commissioning of air conditioner capacity 1.5 tonne 5 star rating as per satisfaction of engineer in charge (Make Ogeneral,Daikin,Mitsubishi ). |
| 9 | Supply of 650/1100V grade stranded/solid aluminum conductor power cable, XLPE insulated, cores laid up, PVC tape/extruded Inner sheathed for multicore, armored with aluminum wire/strip, extruded PVC Type ST2 sheathed, as per IS:7098 (Part 1) 1988, ISI marked as per following sizes. (excluding cost of laying). (Earthing will be measured separately and need not be quoted under this item). All complete as required and and as directed by Engineer-in-charge.3½C x 70 Sq.mm A2XFY Cable |
| 10 | Supply, Pulling, End Termination, Testing and Commissioning of following pair 0.5mm armored telephone cable annelid tinned electrolytic grade copper conductor, PVC insulated, twisted pairs in concentric layers, overall PVC sheated in existing suitable size medium class PVC conduit.-5 Pair |
| 11 | Supplying, Fixing, Testing and Commissioning of MDF Enclosure, ITD/DOT approved, indoor type with wall mounting/concealed facility having front door with lock along with aluminum frame for mounting disconnection type Krone modules with silver plated terminal contacts, cabinet fabricated out of 18 SWG CRCA sheet with powder coating in appropriate manner and suitable for following capacity of pairs, including Krone make modules, crimping and terminations, etc. complete with all accessories and fixing materials as required and as directed by Engineer-in-charge. 50Pair Tag Block with MDF enclosure |
| 12 | Supplying and erecting Digital/ PCM/ TDM EPABX system having SMT design, system with flexible universal slots, inbuilt Auto attendant facility, Minimum 15 Nos. conference, Analog extension line, Calling GSM, EandM line, PRI/ EI/ and VOIP program me through Analog Telephone Digital Key from Ethernet, Public Address cord shall have unrestricted simultaneous dialing facility, QSIG protocol on PRI, 95/ STD/ ISD/ local- locking, class of service, Quick Dial, Single Digit Dialing of any two external nos. Once only ring device, Boss - Secretary Do Not Disturb facility, Power Down Mode, HOT Line, HOT outward dialing, Day night mode, Auto Call back, Bargen, Call pick-up and Call Transfer, Call Transfer while Ringing, with Voice Guide System, (DISA), Caller ID (CLI), CLI baseECF, CLI base routin Internet Ready Port, External Music Port, Call Dudgeting, Call Most Calculation (ASMDR), DID Direct Inverse Dialing, External Music Input, Fax Homing, Global Directory printing with following facilities.Nos. of Extension- 50, Nos. of Junction-10, Nos. of Expandable Ports-20, Operator Console-2, Compatible- ISDN and Networking. |
| 13 | Supply, Installation testing and commissioning of patch cord-CAT-6 RJ45 Patch Cord UTP 1 Mtr. |
| 14 | Supply, Installation testing and commissioning of patch cord CAT-6 RJ45 Patch Cord UTP 2 Mtr. |
| 15 | Supply Installation, Testing and Commissioning of 19` modular patch panel. 24-Port 1U RJ-45 Data Ports (I/O shall not be PCB mounted) complete with all accessories and fixing materials as required and as directed by Engineer-in-charge. |
| 16 | Supply Installation, Testing and Commissioning of 19` modular patch panel. 24-Port 1U RJ-11 Telephone Ports (I/O shall not be PCB mounted) complete with all accessories and fixing materials as required and as directed by Engineer-in-charge. |
| 17 | Supply, Installation, Testing and Commissioning of following port 10/100/1000Mbps GIGABIT 24-port smart manageable switch for data networking complete with all accessories and fixing materials as required and as directed by Engineer-in-charge. |
| 18 | Supply, Installation, Testing and Commissioning of following 19` wall mounted rack with lockable front transparent glass door, ventilated top and bottom, 2-Pairs of front and back adjustable mounting rails, fully powder coated rigid steel body made up of min. 1.2mm thick CRC mild steel having 1Nos roof mounting cooling fan, 1Nos power strip comprising of 6Nos 5A socket and 2Nos cable managers with 1Set of mounting hardware complete with all accessories and fixing materials as required and as directed by Engineer-in-charge. 12U cabinet, 600mm (W) X 450mm (D) |
| 19 | Supplying, installation, testing and commissioning of front operated, front/back access, cubicle type, indoor duty, floor/wall /recess/ surface mounted (as specified below), totally enclosed dust and vermin proof switch boards/panels with minimum Ingress protection classification of IP54, fabricated fabricated in compartmentalized design from 2mm thick CRCA sheets for frame work and covers, 3 mm thick for gland plates,including cleaning and finishing complete with 7 tank process with dip coat priming and epoxy powder coated finish in approved shade. The panels must be suitable for 415V 3-Phase, 4 Wire, 50Hz, system, must be able to withstand symmetrical fault level of 70kA (as specified for various panels) for 1sec. at 415V and must include all interconnections, earthing and bonding requirements etc. The panels must conform to Drawings and Standards specified in relevant specifications, as required and as given below.The Switch boards shall be provided with detachable gland plates for entry of cables from the top as required.All live accessible parts shall be shrouded and all equipment shall be finger touch proof. SMC/DMC shrouds and bus bar supports suitably spaced shall be used. Hinged doors with pad locking facility shall be provided on all outgoing feeders with switch handles lockable in OFF position.The panel shall have capacity extensible type TPN Aluminum Bus Bar with bar type feeder connections, spacer setwith full sized neutral.Earthing all components, frames etc. to a common internal copper earth bar as required by the fault withstand level specified for the board.All accessories and supporting structures such as channels, ISMC-100 base frame, mounting brackets, lifting lugs, panel heaters, ventilation arrangement etc. shall be provided as required.Panel/Switchboard design shall be compact and components/ accessories of compact sizes shall be used to economize the room space available. Employer reserve the right to seek compact items in place of larger ones.Surge Protection Device shall be Type 1 / Class B SPD shall be provided in all panels for all Main Distribution Board IncomersSurge Protection Device shall be Type 2 / Class C SPD shall be provided in all panels for all Submain Distribution Board IncomersMAIN LT PANEL |
| 20 | Supplying, installation, testing and commissioning of front operated, front/back access, cubicle type, indoor duty, floor/wall /recess/ surface mounted (as specified below), totally enclosed dust and vermin proof switch boards/panels with minimum Ingress protection classification of IP54, fabricated fabricated in compartmentalized design from 2mm thick CRCA sheets for frame work and covers, 3 mm thick for gland plates,including cleaning and finishing complete with 7 tank process with dip coat priming and epoxy powder coated finish in approved shade. The panels must be suitable for 415V 3-Phase, 4 Wire, 50Hz, system, must be able to withstand symmetrical fault level of 70kA (as specified for various panels) for 1sec. at 415V and must include all interconnections, earthing and bonding requirements etc. The panels must conform to Drawings and Standards specified in relevant specifications, as required and as given below.The Switch boards shall be provided with detachable gland plates for entry of cables from the top as required.All live accessible parts shall be shrouded and all equipment shall be finger touch proof. SMC/DMC shrouds and bus bar supports suitably spaced shall be used. Hinged doors with pad locking facility shall be provided on all outgoing feeders with switch handles lockable in OFF position.The panel shall have capacity extensible type TPN Aluminum Bus Bar with bar type feeder connections, spacer setwith full sized neutral.Earthing all components, frames etc. to a common internal copper earth bar as required by the fault withstand level specified for the board.All accessories and supporting structures such as channels, ISMC-100 base frame, mounting brackets, lifting lugs, panel heaters, ventilation arrangement etc. shall be provided as required.Panel/Switchboard design shall be compact and components/ accessories of compact sizes shall be used to economize the room space available. Employer reserve the right to seek compact items in place of larger ones.Surge Protection Device shall be Type 1 / Class B SPD shall be provided in all panels for all Main Distribution Board IncomersSurge Protection Device shall be Type 2 / Class C SPD shall be provided in all panels for all Submain Distribution Board IncomersInput Panel |
| 21 | Supplying, installation, testing and commissioning of front operated, front/back access, cubicle type, indoor duty, floor/wall /recess/ surface mounted (as specified below), totally enclosed dust and vermin proof switch boards/panels with minimum Ingress protection classification of IP54, fabricated fabricated in compartmentalized design from 2mm thick CRCA sheets for frame work and covers, 3 mm thick for gland plates,including cleaning and finishing complete with 7 tank process with dip coat priming and epoxy powder coated finish in approved shade. The panels must be suitable for 415V 3-Phase, 4 Wire, 50Hz, system, must be able to withstand symmetrical fault level of 70kA (as specified for various panels) for 1sec. at 415V and must include all interconnections, earthing and bonding requirements etc. The panels must conform to Drawings and Standards specified in relevant specifications, as required and as given below.The Switch boards shall be provided with detachable gland plates for entry of cables from the top as required.All live accessible parts shall be shrouded and all equipment shall be finger touch proof. SMC/DMC shrouds and bus bar supports suitably spaced shall be used. Hinged doors with pad locking facility shall be provided on all outgoing feeders with switch handles lockable in OFF position.The panel shall have capacity extensible type TPN Aluminum Bus Bar with bar type feeder connections, spacer setwith full sized neutral.Earthing all components, frames etc. to a common internal copper earth bar as required by the fault withstand level specified for the board.All accessories and supporting structures such as channels, ISMC-100 base frame, mounting brackets, lifting lugs, panel heaters, ventilation arrangement etc. shall be provided as required.Panel/Switchboard design shall be compact and components/ accessories of compact sizes shall be used to economize the room space available. Employer reserve the right to seek compact items in place of larger ones.Surge Protection Device shall be Type 1 / Class B SPD shall be provided in all panels for all Main Distribution Board IncomersSurge Protection Device shall be Type 2 / Class C SPD shall be provided in all panels for all Submain Distribution Board IncomersOutput Panel |
| 22 | Supplying, installation, testing and commissioning of true parallel redundant 2x10KVA online, UPS system suitable for providing power supply to emergency lighting and Computerized Control panel load of approved make, suitable for incoming 415volts, 3phaseplus 10% -20%, 50Hz, supply and 3-phase 415 volts, output voltage, variation ±1%, including in-built isolation transformer, IGBT rectifier modules/dual converter, static switch, inverter, filters, by-pass and static transfer switch for automatic switch over without giving any break of power, maintenance bypass switch, Microprocessor/software controlled annunciation, protection (including against input phase reversal), and menu run diagnostic module, associated cabling and connections/terminations, erection including associated foundation/masonry or RCC work for mounting on base channels etc. complete as per specifications and as required.Note-1:The price of above item is exclusive of automatic changeover switch suitable for terminating 2nos of fire survival copper conductor cables as per technical specifications on the incoming side of UPS and is included in the UPS ATS item. The Automatic changeover switch may be wall mounted in the UPS room or as provided. From changeover switch to UPS, the connection should be through an adequately rated fire survival copper cable, and RS485 port for display of ON/OFF status of UPS on BMS workstation through MODBUS protocol.Supply, Installation, Testing and Commissioning `sealed maintenance free lead acid` each having 30 minutes back up time at full load with interconnecting cables, racks and standard accessories UPS above. Battery shall comply with relevant regulations and battery racks shall be made of acid resistant material.All the items/parts mentioned in relevant clauses of the MandW specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded. |
| 23 | Supply, installation, testing and commissioning of indoorUL ListedIPN/W TDN Low-Light IR Dome Camera, 1/3`` CMOS sensor, 2 MP resolution @ 25fps or better, Fixed 2.8 mm lens, Auto Iris, Day Night cameras, Vandal Proof and Motion detection, POE, (high resolution cameras / 4CIF)ONVIF compliant complete withIP 66 Dome Housing, Connectors, Lens, Camera Mounts, Power Supply, I/O and all Ancillary Equipment and all accessories. |
| 24 | Supply, installation, testing and commissioning of OutdoorUL ListedIPN/W TDN Low-Light IR Bullet Camera, 1/3`` CMOS sensor, 2 MP resolution @ 25fps or better, varifocal 2.7 - 12 mm lens, Auto Iris, Day Night cameras, Vandal Proof and Motion detection, POE, (high resolution cameras / 4CIF)ONVIF compliant complete withIP 66 Dome Housing, Connectors, Lens, Camera Mounts, Power Supply, I/O and all Ancillary Equipment and all accessories. |
| 25 | Supply installation Testing and Commissioning of Video Management Software and all Cameras shall be of same make for seamless Integration*web based client allows viewing and exporting video without installing any software and server client Architechture.*Imports users and roles from existing LDAP servers to reduce administrative overhead,and enables single sign-on (SSO)*Capable of listening for ASCII commands*Check on VMS and camera health using SNMP*Supports IPv4 and IPv6 cameras*Enables and supports Risk Management Framework (RMF),incorporates FIPS 140-3 validated cryptographic modules*TLS-based encryption over HTTPS*VMS Shall be able to Reduce Frame rate and FPS on recorded video to increase stoarge capacity * Bidder to consider liscences as per mentioned BOQ Approved Makes:Pelco/ Axis/Avigilon/ Mobotix |
| 26 | Supply, installation, testing and commissioning of Layer 2 managed switch with 24 ports (RJ-45), POEas to support all cameras15% spare ports complete with supply. The switch shall have 1 GB port to communicate with other switches including Passive componentsinbuilt 2 SFP ports including SFP modules, POE compliant ports,rack mountable, SMPS power supply and other termination accessories (Like Pigtails/ LIUs/Convertors/Splicing equipment , Patchpanel, PatchCordEtc.)completeasperspecifications and as required. Rack shall be included. |
| 27 | Supply installation Testing and Commissioning OF 32Ch Network Video Recorder: Connect Up to 32 IP CamerasUp to 12 Megapixels Resolution, HDMI and VGA independent outputs providedHDMI output of 4K (3840 × 2160) resolutionVGA output with output upto 1920 × 1080Support H.265Incoming Bandwidth 250 Mbps4 SATA Hard Disks4 SATA interfaces for 4 HDDs and capacity of each HDD upto 10TBFront panel: 2 × USB 2.0Rear panel: 1 × USB 3.0Alarm I/O 16/4, 2 RS-485, 1 RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, CE, FCC, BIS certified. |
| 28 | Supply installation Testing and Commissioning of hard disk storage 10TB HDD surveillance grade |
| 29 | Supply, installation, testing and commissioning of video management client workstations as requiredincluding 42` full HD LED 24x7 application, keyboard, Joystick, mouse, and all required accessories complete as per specifications and as required. The licence support shall be for life time. (Samsung/LG) |
| 30 | Supply, Installation testing and commissioning of CAT 6 Patch Cords - 5M length at rack side |
| 31 | Supply, Installation testing and commissioning of CAT 6 Patch Cords - 2M |
| 32 | Supplying, installation, testing and commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories-2 Nos.Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation / communication suitable for 20 Nos.talk back unit -1 set.Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set.Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No.Gooseneck microphone with stand and ON/OFF switch -1 No.Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters and ammeters terminal blocks etc. complete as required -1 set.Battery charger trickle cum boost to take complete load of fire alarm and PA system complete with all accessories including providing and fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. |
| 33 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Two Loop Panel |
| 34 | Supplying, installation, testing and commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. |
| 35 | Supplying, installation, testing and commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 36 | Supplying, installation, testing and commissioning of intelligent analog addressable photo thermal detector complete with mounting base complete as required. |
| 37 | Supplying, installation, testing and commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 38 | Supplying, installation, testing and commisssioning of intelligent addressable programmable sounder complete as required. |
| 39 | Supplying, installation, testing and commisssioning of fault isolater addressable complete with base as required. |
| 40 | Supplying, installation, testing and commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 41 | Supplying, installation, testing and commissioning of addressable phone control module complete as required. |
| 42 | Supplying, installation, testing and commissioning of addressable manual call point complete as required. |
| 43 | Supplying, installation, testing and commissioning of addressable horn cum strobe complete as required. |
| 44 | Supplying, installation, testing and commissioning of fire fighter telephone handset complete as required. |
| 45 | Supplying, installation, testing and commissioning of fire fighter phone jack complete as required. |
| 46 | Supplying, installation, testing and commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 47 | Supplying, installation, testing and commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 48 | Supplying, installation, testing and commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required. |
| 49 | Supplying, installation, testing and commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. |
| 50 | Supply and installation of reading chair Dimension-450x450x900 make Geeken or equivalent,as per references shared in annexure,complete upto satisfaction of engineer incharge |
| 51 | Supply and installation of High Stool chairDimension-450x450x1000make Geeken or equivalent, as per references shared in annexure,complete upto satisfaction of engineer incharge. |
| 52 | Supply and installation of Chair500X500X900make Geeken or equivalent, as per references shared in annexure, complete upto satisfaction of engineer incharge. |
| 53 | Supply and installation of ChairDimension-500x500x900make Geeken or equivalent, as per references shared in annexure, complete upto satisfaction of engineer incharge |
| 54 | Supply and installation of reading desk with 18mm thk Prelaminated HDHMR(make Action Tessa / century ply or equivalent)top of size(1200x450x750)all surfaces to be finished with 0.8 mm laminate pasted with adhesives as per specification and to be fixed on polished Metal base with nails screws etc., of approved make and size as per the design and architectural dwg. Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution complete upto satisfaction of engineer incharge. |
| 55 | Supply and installation of wall mounted reading desk with 18mm thk Prelaminated HDHMR(make Action Tessa / century ply or equivalent)top of size(5325x450x40) all surfaces to be finished with 0.8 mm laminate pasted with adhesives as per selection fixed on MS frames atplus 900mm from FFL with nails screws etc., of approved make and size as per the design and architectural dwg. Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution complete upto satisfaction of engineer incharge. |
| 56 | Supply and installation of wall mounted reading desk with 18mm thk Prelaminated HDHMR(make Action Tessa / century ply or equivalent)top of size(3080x450x40) all surfaces to be finished with 0.8 mm laminate pasted with adhesives as per selection fixed on MS frames atplus 900mm from FFL with nails screws etc., of approved make and size as per the design and architectural dwg. Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution complete upto satisfaction of engineer incharge. |
| 57 | Supply and installation of Computer Table with 18mm thk Prelaminated HDHMR(make Action Tessa / century ply or equivalent)top all surfaces to be finished with 0.8 mm laminate pasted with adhesives as per selection of size(1200x600x750) as per specification fixed on polished Metal Base. A CPU compartment made in 12mm thk HDHMR all surfaces to be finished with 0.8 mm laminate as per selection of size (300x600mm) with nails screws etc., of approved make and size as per the design and architectural dwg. Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution complete upto satisfaction of engineer incharge. |
| 58 | Supply and installation of Computer Table with 18mm thk Prelaminated HDHMR(make Action Tessa / century ply or equivalent)top all surfaces to be finished with 0.8 mm laminate pasted with adhesives as per selection of size(1800x600x750) as per specification fixed on polished Metal Base. A CPU compartment made in 12mm thk Prelaminated HDHMR all surfaces to be finished with 0.8 mm laminate as per selection of size (300x600mm) with adhesives, nails ,screws etc., of approved make and size as per the design and architectural dwg. Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution complete upto satisfaction of engineer incharge. |
| 59 | Supply and installation of Reception Table with 18mm thk Prelaminated HDHMR(make Action Tessa / century ply or equivalent)carcass of size 2200x600x1050mm with all internal surfaces to be finished with 0.8 mm laminate pasted with adhesives as per selection to have 100 mm recessed skirting of aluminum powder coated flashing and all internal surfaces to be finished with 0.8 mm laminate as per selection with adhesives,nails,screws etc., of approved make and size as per the design and architectural dwg. Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution complete upto satisfaction of engineer incharge. |
| 60 | Supply and installation of Desk with 18mm thk Prelaminated HDHMR(make Action Tessa / century ply or equivalent) carcassof size 2200x900x750mm with all internal surfaces to be finished with 0.8 mm laminate pasted with adhesives as per selection to have 100 mm recessed skirting of aluminum powder coated flashing and all internal surfaces to be finished with 0.8 mm laminate as per selection.Side Storage of size 1800x600x600mm with1) 2 Pull-out drawers of width 600X300mm.2) open shelves in remaining spacewith All adhesives, nails screws etc., of approved make and size as per the design and architectural dwg. Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution complete upto satisfaction of engineer incharge. |
| 61 | Supply and installation of coffee table of size Dimension-Dia 500x450with 18mm thk Prelaminated HDHMR(make Action Tessa / century ply or equivalent) top with all surfaces to be finished with 0.8 mm laminate pasted with adhesives as per selection with powder coated metal base using nails,screws etc., of approved make and size as per the design and architectural dwg. Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution complete upto satisfaction of engineer incharge. |
| 62 | Supply and installation of book shelf Dimension-1500x425x1800with 18mm thk prelaminated HDHMR(make Action Tessa / century ply or equivalent) carcuss (ISI approved). Book shelf to have 100 mm recessed skirting of aluminum powder coated flashing and all internal surfaces to be finished with 0.8 mm laminate as per selection.Laminated shelves of HDHMR board to be fixed in book shelf in 4 equal divisions fixed using nails screws etc., of approved make and size as per the design and architectural dwg. Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution complete upto satisfaction of engineer incharge. |
| 63 | Supply and installation of book shelf Dimension-1500x425x1800with 18mm thk prelaminated HDHMR(make Action Tessa / century ply or equivalent) carcuss (ISI approved). Book shelf to have 100 mm recessed skirting of aluminum powder coated flashing and all internal surfaces to be finished with 0.8 mm laminate as per selection.Laminated shelves of HDHMR board to be fixed in book shelf in 4 equal divisions. Shelves to be provided on sides as well fixed using nails,screws etc., of approved make and size as per the design and architectural dwg. Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution complete upto satisfaction of engineer incharge. |