| 1 | Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100)grade) and joints filled with cement mortar 1 :2 (1 cement:2 marbledust mixed with water proofing compund all complete as per directionof Engineer-in-charge. |
| 2 | Making khurras 450x450mm with average minimumthickness 50mm cement concrete 1:2:4 over P.V.C. sheet1 mtr x 1mtrx40micron finished with 12mm cement plaster1:3 and one coat of neat cement rounding edges andmaking and finishing the out let complete. |
| 3 | Providing and fixing external grade board solid core (tripple core) singleleaf boiling water and termite resistant flush door shutters ISI 2202-67marked using phenol formaldehyde resin in glue both sides with approvedsteel fittings complete as per annexure\"A\". Commercial veneer 35 mm thick |
| 4 | For external teak wood lipping on flush door |
| 5 | Repair of existing steel glazed doors, windows and ventilator, MSsheet door, garage doors, compound wall gates etc. by weldingdrilling complete include. Cost of welding rods and hire charge ofwelding meachine and TP etc complete |
| 6 | Labour charges for repair to door / window without using anymaterial such as applying randha (finishing) tightening of bolts &screw etc. |
| 7 | Renewing glass panes, with putty and nails wherever necessary4 mm thick plain glass panes |
| 8 | Providing and fixing steel glazed doors windows andventilator shutters of standard rolled steel section jointsmitred and welded with steel lugs 13x3mm, 10cm, longembedded in cement concrete block 15x10x10cm of 1:3:6 ( 1cement : 3 coarse sand : 6 graded stone aggregate 20mmnominal size) or with wooden plugs and screws or rawl plugsand screws with fixing clips or with bolts and nuts as requiredincluding providing and fixing of plain glass panes 4mm thickwith coper glazing clips and special metal sash putty ofapproved make or metal beading with screws completeincluding priming coat of approval steel primer excluding thecost of metal beading and other fitting except necessaryhings of pivots steel handles peg stay etc. as required.Partly fixed and partly openable (fixed area not to exceed 33%). |
| 9 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gaugeto the metal frame of rolled section by metal beading 20 x 3mm with suitable screw at not exceeding 150mm distance. |
| 10 | Providing and fixing square bars or other flat welded towindow ventilatiors etc. |
| 11 | Dismantling of flooring with care including stacking ofserveciable material and disposal of unserviceable materialwith in 50 mtr lead for:Cement concrete flooring |
| 12 | Dismantling old plaster or skirting raking out joints andcleaning the surface for plaster including disposal ofrubbish to the dumping ground within 50 mtr lead |
| 13 | Polished Blue Kota stone flooring skirting laid over 20mmthick base of CM 1:4 and jointed with gray cement slurry tomatch the shade of the slab including rubbing and polishingcompleteFor area of each slab from 901Sq.cm to 2000 sq.cm (b) 25 mm thick slab |
| 14 | Plaster on new surface on wall in cement sand mortar 1:6including raking of joints etc. complete fine finish:25mm thick |
| 15 | Finishing wall with vinyl satin finish coating paints of approved shade with two or more coats including sand papering, priming coat, making surface with putty or plaster of paris etc. complete in all respects. |
| 16 | Distempering with oil bound washable distemper of approvedbrand and manufacture to give an even shade including allscaffolding Newwork(twoormorecoats)overandincludingscrapping and priming coat with cement primer |
| 17 | Painting with enamel paint of approved brand andmanufacture to give an even shade:Two or more coats on new work |
| 18 | Repair to damaged RCC slabs, beams and columns etc for strengtheingwith cement mortar 1 : 3 in following stepsi) Choping losse and cracked concrete to required depth, cleaning theexposed surface of steel and concrete with wire brush and sand papering ,cleaning of concrete surface with water as necessary and getting dried.ii) Applying Epoxy primer on the exposed steel bars.iii) Applying Epoxy hardener and resin mix (as per manufectured\"sspecification) on concrete and steel bars with brush.iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface andallow it to dry for one day.v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mmcomplete.vi) Cure the plastered surface for 15 days |
| 19 | Providing and fixing Ist quality standard White/ ivory,grey, fumared brown, light green, light blue and other light shades GlazedTiles of (confirming to IS : 13753 & IS 13622) of size 300 mm x200 mm in walls, floors, steps, pillars etc. laid on a bed of neatcement slurry finished with flush pointing in white cement mixedwith pigment to match the shade of tile complete (excluding thecost of cement plaster on walls & pillars ). |
| 20 | Add extra over item for marble printed, granite shade tiles |
| 21 | Providing and fixing Ist quality MAT finished ceremic tiles size 300x 300 mm confirming to IS: 13755 & IS: 15622 colour such aswhite, grey, Ivory, fume red brown in walls, floors, steps, pillarsetc. laid on a bed of neat cement slurry including nicely finishedjoints using water proof joint filler powder and finishing with flushpointing in white cement mixed with pigment to match the shadeof tile complete (including the cost of cement mortar bed 1:4). |
| 22 | Add extra for using tiles of size 300 x 450 mm |
| 23 | P & F PVC Storage Tank (IS : 12701 marked indicatingthe BIS license No), of approved make with cover, 25mmdia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipewith plug & socket, including making connection etc.,complete of approved design:Tripple layer1000 litres capacity. |
| 24 | Add extra for Hoisting charges for each floor and Tripplelayered water tanks |
| 25 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.)approved quality /make including joining the pipe with solventcement rubber ring and lubricant. |
| 26 | 110mm dia |
| 27 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for soil and waste dischargesystem (IS:13592 : 1992 Marked) of approved quality /make |
| 28 | 110 mm dia |
| 29 | 75 mm dia |
| 30 | Providing and Fixing Unplasticized Poly Vinyl Chloride(UPVC) SWR Pipes fittings type B for soil and wastedischarge system (IS:13592 : 1992 Marked) of approvedquality /make. |
| 31 | Bend 87.5 Dg. |
| 32 | 75 mm |
| 33 | 110 mm |
| 34 | Bend 45 Dg. |
| 35 | 75 mm |
| 36 | 110 mm |
| 37 | Single Tee |
| 38 | 75 mm |
| 39 | 110 mm |
| 40 | Nahni Trap with Jali 4” |
| 41 | Vent Cowel 100 mm |
| 42 | Supply & fixing G.I. Union ISI marked in G.I. pipe line asrequired complete in all respect of size : |
| 43 | 15mm dia nominal bore |
| 44 | 25mm dia nominal bore |
| 45 | P & F Full-way Valve (IS:778 Mark) or wheel valve ofapproved make : |
| 46 | Gun-metal 15mm nominal bore. |
| 47 | (-do-) 25mm nominal bore |
| 48 | CPVC Plumbing Pipe For Hot & Cold ISI SDR-11 |
| 49 | 20 mm |
| 50 | 25 mm |
| 51 | CPVC Plumbing Pipe Fitting |
| 52 | Elbow |
| 53 | 20mm |
| 54 | 25 mm |
| 55 | Coupler |
| 56 | 20mm |
| 57 | 25 mm |
| 58 | Tee |
| 59 | 20mm |
| 60 | 25mm thick |
| 61 | CPVC BR Elbow 20x15mm |
| 62 | CPVC BR MTA |
| 63 | 20MMX15MM |
| 64 | 25MM |
| 65 | Brass / Gun metal Half-turn wt. 1 Kg. of approved quality /make, 25mm nominal bore. |
| 66 | P & F Indian type white glazed vitreous china Ist quality W.C.orissa pan (I.S: 2556 Mark) with 100 mm vitreous china P or S trapincluding cutting and making good the wall and floor.580X440 MM |
| 67 | P & F WVC wash basin (Ist quality, I.S.: 2556 Mark) of approved make with C.I. brackets duly painted 1 No 15 mm C.P. pillar cock(I.S. : 8934 Mark) & 32 mm C.P. brass waste coupling of approvedmake, 25 mm G.I. waste pipe complete including cutting & makinggood the wall of superior quality and manufacturer Size 580 x 450 mm Each 1936.00 |
| 68 | P & F Pilllar Cocks (IS :8934 Mark) of superior quality and approved make C.P. Pillar cock, 15 mm dia nominal bore Each 532.00 |
| 69 | Construction of manhole in all type of soil inner size 90 X 60 Cm. 450 mm thick masonry in CM 1:6, 10 Cm. thick cementconcrete 1:5 10 in foundation, 20 mm thick inside plaster inCM 1:6, finished with floating neat cement, 50mm thick M-15grade C.C. flooring, making channels, 80mm thick stone slabcovering with 40mm thick M-15 grade C.C. flooring, Cementcover with frame of 450mm dia, earthwork etc. complete asper design including disposal of surplus earth within 50 mtr. lead. Depth upto 0.50M Each 3542.00 |
| 70 | Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation,20mm thick insider plaster in Cm 1:6, finished with floatingneat cement, 50mm thick M-15 grade C.C. flooring ,earthwork etc. complete as per design including disposal ofsurplus earth within a lead of 50 mtr Inside size 300 X 300 mm depth upto 0.5 M Cement coverwith frame. Each 1440.00 |
| 71 | -do- size 450 x 450mm depth upto 0.5 M Cement cover with |
| 72 | Providing and laying in position cement concrete including curing compaction etc . Complete in specified gradeexcluding the cost of centering and shuttering. All work upto plinth level using crusher broken aggregate 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stoneaggregate 40 mm nominal size) Cum 2896.00 |
| 73 | P & F GI pipes ( Internal works ) with GI fittings excludingUnion (IS:1239 mark) and MS clamps, including cuttingand making good the wall and floors. |
| 74 | (a) Exposed on wall |
| 75 | 15mm dia Nominal Bore |
| 76 | \"B\" Class |
| 77 | 25mm dia Nominal Bore |
| 78 | \"B\" Class |
| 79 | P & F Bib Cock (IS : 8931 Mark), Superior quality ofapproved make: |
| 80 | C.P. Brass bib cock,15mm nominal bore. |
| 81 | (-do-) Long body, 15mm nominal bore weight not less than690 gm |
| 82 | Dismantling tile work in floor and roofs laid in cementmortar including stacking of serviceable material anddisposal of unserviceable material within 50 mtr lead |
| 83 | For thickness of tiles 10mm to 25 mm |
| 84 | Providing and laying water proofing treatment in sunken portion ofWCs bathroom etc. by applying polymer modified cementousslurry consisting of appearing: |
| 85 | (I) First layer of slurry of ement @ 0.448 kg/sqm mixed with polymer@ 0.253 kg/sqm This layer will be allowed to air cure for 4 hours. (II) Second layer of slurry of cement @ .242 kg/sqm mixed withpolymer @ 0.126 kg/sqm This layer will be be allowed to air curefor 4 hours followed by water curing for 48 hours.The rates includes preparation of surface treatment & sealing ofall joints corners, junction with polymer mixed slurry. Sqm. 117.00Note :- Rendering/plastering as protective layer if required will bepaid separately. |
| 86 | Filling of sunk portion of roof with earthen pots of requiredheight including filling voids with 1:2:4 light concrete usingbrick bats complete levelling and dressing the surface by50mm thick cement concrete 1:2:4 as per specification. |
| 87 | Providing and laying damp-proof course with cement concretegrade M-150 (1:2:4) mortar prepared with 1 % solution of waterproofcompound, including two coats of hot blown bitumen ( 2 Kg.per sqm) complete as per specification with glass strip 3 mm thickat a distance of 1 m interval: |
| 88 | 50 mm thick |