| 1 | Dismantling ofplain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings. |
| 2 | S & F pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 3 | S & F pre painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 4 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 5 | S&F 1.25mm thick Mild steel sheet / PVC eaves gutters, 150mm dia, galvanised class 3, half round with rounded edges complete all as specified and directed. |
| 6 | S&F 150mm dia Mild steel sheet of 1.25mm thk/ PVC drop ends (for spigot or socket ends) or nozzles complete all as specified and directed. |
| 7 | S&F 150mm dia Mild steel sheet of 1.25mm thk/ PVC stop ends (for spigot or socket ends) or nozzles complete all as specified and directed. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 9 | S&F mild steel work as in band, strap, supports or stay for rainwater, ventilating pipes incl bolts if reqd, hoocks and similar small articles conforming to Fe 290 Gde -E-165 complete all as specified. |
| 10 | S&F roof trusses, framed trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (Beam, tee, angle channel or flat section) incl distance pieces, cleats, nut and bolts conforming to FE-410w (grade 250-E quality A) complete all as specified and directed. |
| 11 | Demolition of reed, lathing, single or Double and plaster or chicken wire lathing on walls all as specified and directed. |
| 12 | M & L precast cement concrete type C-1 , (1:3:6) (using 20mm graded stone aggt) block masonry with solid blocks exc 10cm in width and setting in CM (1:6) complete all as specified and directed. |
| 13 | Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 14 | M&L for reinfored cement concrete (nominal mix) in (1:2:4) type B1 (using 20mm graded aggregate) as in beams, lintels over 1.5m span complete all as specified and directed. |
| 15 | Formwork to sides and soffits of lintels, shelves including suppotrts, beams etc in rough finished and flat surfaces of concrete complete all as specified and directed. |
| 16 | M & L mild steel TMT Bars10mm dia and over cut to length bend to shape required including cranking bending spirally for column, hooking ends & binding with and including mild steel mild steel wire (ann ealed not less that 0.90 mm dia or securing with chip) complete all as specified and directed. |
| 17 | M & L mild steel TMT Bars 6mm to 8mm mm dia and over cut to length bend to shape required including cranking bending spirally for column, hooking ends & binding with and including mild steel mild steel wire (ann ealed not less that 0.90 mm dia or securing with chip) complete all as specified and directed. |
| 18 | Taking down cementplaster on brickor stone masonrysurfaces of walls etc includingrakingout joints, hackingfor key, scrubbingdown with wateretc complete all as specified and directed. |
| 19 | M&L for 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) complete all as specified and directed. |
| 20 | M&L 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement or in the manner specified by the manufacturer and in the proportions indicated all as specified and as directed.Note:-WPC will be measured and paid separately as supply only. |
| 21 | M&L 20mm thick rendering in two layers of 10mm each on brick or block concretemasonry walls in cement mortar (1:4) with WPC incl finished even and smooth w/o using extra cementall as specified. |
| 22 | Supplyonly integral water proofing compond all as specified and as directed. |
| 23 | M & L for Preparing newly plastered surfaces of wall and applying two coat of oil bound distemper over chalk whitining primer over 3mm thick layer of putty all as specified and as directed. |
| 24 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 25 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 26 | M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed. |
| 27 | M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical suface like, dado and skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 10 mm thick screed bed in cement mortar (1:4) complete all as specified and directed. |
| 28 | Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15 cm thickness below or above ground level all as specified and as directed. |
| 29 | M&L 75 mm thick PCC type C-2, (1:3:6) (40mm graded stone aggt) as in path, plinth protection etc., complete all as specified and as directed. |
| 30 | M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed. |
| 31 | M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed. |
| 32 | Dismantling timber scantlings 40 Sqcm and over in section, in any position (framed work) all as specified and directed. |
| 33 | M&L well seasonedsecond class hard wood timber scantling in timber framed work; fixed in clean sawn complete all as specified. |
| 34 | Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards /slabs /blanketsany thickness, including cover fillets. |
| 35 | S&F 605 X605 mm GI frame work forfor seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to sorrounding wall using nylon sleeves and screws at 450 mm centre to centre /intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from suffit at approx 900 mm centre to centre with GI cleats and steel expansion fastner with and including ceiling section (not exc 1.2 m length)of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10 .5 mm fixed to the intermediate channel with connecting clieats across the intermediate channel at 457 mm centre to centre. |
| 36 | S&F hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasterners 12.5mm dia 40mm long complete all as specified and as directed. |
| 37 | M&L 4mm thick asbestos cement design (600x600x4mm) building boards, fixed or laid /inserted to GI snap grid framework with screw in ceilings. |
| 38 | M&L three coats of white wash on ceiling onAC boards complete all as specified and directed. |
| 39 | Taking down chowkhatsor frame n.exc 1.50 andeach with shutter (without taking off shutters from the frame) complete all as specified and directed. |
| 40 | Taking down chowkhatsor frame exc 1.50 andnot exc 4 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed. |
| 41 | S&F Steel windows with side hung shutters incl projecting type hinges with steel handle, and steel peg stay complete with glazing bars complete all as specified and directed. |
| 42 | S&F Steel windows with side hung shutters incl projecting type hinges with steel handle, and steel peg stay complete withoutglazing bars complete all as specified and directed. |
| 43 | S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 44 | S&F 3mm thick sheet glass, oridinary quality and glazing with oil putty in square n etc 0.5 sqm in each pane complete all as specified and directed. |
| 45 | S&F Pressed steel frames of size 165x60 mm for door with oneor more rebates including necessary fixing lugs, butt hinges, lock strike plate etc., complete as specified. |
| 46 | S & F 30mm thick flush door shutters , solid core construction with black board core and plywood face panels,commercial type on both face complete all as specified hard& fitted to chowkats complete all as specified and directed. |
| 47 | S & F 30 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass gauge etc with cut and mitred beads for securing glass etc sizeof member of shutter as specified in SSR Pt-1 section 8 and clause 8.24 (a) complete all as specified and directed. |
| 48 | S & F Galvanised wire cloth, 0.63 mm nominal dia of wire and average width of aperature 1.4mm and fixed with tinted tacks or galvanised wire staples as in fly proof window and door complete all as specified and directed. |
| 49 | S&F 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 50 | S&F 200mm size aluminium anodised barrel tower bolts of extruded sections complete all as specified and directed. |
| 51 | S & F 150mm size aluminium handle cast type anodised complete all as specified and directed. |
| 52 | S & F 300 mm long aluminium alloy, anodised sliding door bolt with hasp and staple (bolt type ) and fixing clip of sheet cost or extruded section or cost aluminium alloy & fixed complete all as specified and directed. |
| 53 | S&F in repairs 20mm dia curtain rails, mild steel, chromium plated with incl fixing brackets, stops, rollers etc.,complete all as specified and directed. |
| 54 | M&L prepration of old painted steel surfaces of any description, not otherwise described, over 10cm width & applying one coat of synthetic enamel paints all as specified and directed. |
| 55 | M&L for Preparation of new painted steel and iron surfaces of any description and in any position over 10 cm width or girth as in roof not other wise specially described and applying one coat ofIst grade enamel paint over a coate of red oxide primer zinc chromeallas specified and as directed. |
| 56 | M&L preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 57 | S&F of 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wallscomplete all as specified and as directed. |
| 58 | S & F 110 mm bore PVCPipes single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed. |
| 59 | S&F PVC (SWR) bends 110mm dia complete all as specified and as directed. |
| 60 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil. |
| 61 | Excavation over areanot exceeding 1.5m deep and getting out in soft/loose soil complete all as specified and as directed. |
| 62 | Excavation over areaexceeding 1.5m deep not exc 3.0 and getting out in soft/loose soil complete all as specified and as directed. |
| 63 | Excavation in trenches n exc 1.50m wide and not exc 1.50m deep for foundation and getting out in soft / loose soil complete all as specified and as directed. |
| 64 | M&L PCC type D-2 (1:4:8) (using 40mm graded stone agg) in foundation filling and mass concrete complete all as specified and as directed. |
| 65 | M&L Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm in soft / loose sioil.felling under floor complete all as specified and as directed. |
| 66 | Removing excavated material not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and as directed. |
| 67 | M & Lpreparationplastered or unplastered newsurfaces of walland applying three coat of white wash complete all as specified and directed. |
| 68 | S&Frolled section as in main and cross beams hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angles cleats or other connecting plates in FE-410W (Gde E-250) quality A complete all as specified and directed. |
| 69 | M & L hardcore of gauge exc 63mm but n exc 100mm,deposited, spread and levelled in layersn exc 15 cm thick watered and rolled /rammed to a true surface complete all as specified and directed. |
| 70 | M & L for 75 mm thick cement concrete type D-1,(1:4:8) (40 mm graded aggregate) as in sub base or sub flooring fininshing the surfaceeven and rough to receive the topping layer complete all as specifiedand directed. |
| 71 | M & L screed bed or bedding layer of mortar 15 mm thick for laying floor finishes incement mortar (1:6) complete all as specified. |
| 72 | Brass chromium plated trap ‘P’ or ‘S’ pattern for wash basins and sinks with inlet and outlet, screwed for pipe or connections, and with one cleaning cap and fixedcomplete all as specified. |
| 73 | M & L for modular fly ash bricks as in brick workstraight or curved on plan exceeding 6m mean radious built in cement mortar (1:6) complete all as specified and as directed. |
| 74 | Formwork to soffits of suspendes slab such as slabs, floor slabs, landings and smillar work; not exceeding 200 mm thick (horizontal and sloping) for rough finished surfaces complete all as specified and directed. |
| 75 | M & L Reinforced cement concrete (Nominal mix ) type B1 (1:2:4) (20 mm graded crushed stone aggregate) as in slabs supported on walls, roof beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 76 | M&L for precast cement concrete type-B-1, (1:2:4) (20 mm graded aggregate) as incover slabs,set in cement morter (1:6) complete all as specified and as directed. |
| 77 | M&L mild steel deformed bars 10mm dia and over cut to length bend to shape required incld cranking bending spirally for hooping for column, hooking ends and binding with and incld mild steel wire (annealed not less than 0.90mm dia or securing with clips complete all as specified and as directed. |
| 78 | M & L 15mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed. |
| 79 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 80 | M&L for Point wiring complete with 1.5 sqmm single core PVC insulated and PVC unsheathed FRLS multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves, Dash fastners and cadmium plated screws including sunken junction box not less than 3.0 mm thick concealed in wall, mounting accessories like switches, sockets fan regulators with 3.0 mm thick Laminated sheet top covers etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly for the following :- make : Polycab/Havells/RR Cables/KEI |
| 81 | All as peritem No.80 here – in – before but for one 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size complete all as specified and directed. |
| 82 | All as peritem No.80 here – in – before but for one 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size complete all as specified and directed. |
| 83 | All as per item No.80 here – in – before but for one 3 pin socket outlet, 15 Amps, independent, with cables 4 sq. mm size complete all as specified and directed. |
| 84 | Supply and fix Switch piano, flush type single pole, one way 6 Amp all as specified and as directed. |
| 85 | Supply & Fixing Ceiling rose, 3 phase /PVC/ polycarbonate, isolated body complete all as specified and as directed. |
| 86 | Supply and fix Switch socket combination 2 in 1, 6A flush type complete all as specified and as directed. |
| 87 | Supply and fixing Switch socket combination 3 pin 16A, flush type complete all as specified and as directed. |
| 88 | Supply and fixing energy efficient LED tube lights fitting 4\", 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 89 | Supply and fixing LED light fitting 1x9W/10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete including taking down old unsv fitting complete all as specified and directed. |
| 90 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 91 | S & F inLED retro fit lamp B-22holder base with poly carbonate body and aluminium heat shrink of 12 Wcomplete all as directed. |
| 92 | M&L for Earthing in repairs completewith galvanizedsteelearthplateelectrode600 x 600 x 6 mmburieddirectlyinground( earthpitnotlessthan2.25 mdeepbellowgroundlevel )withtopedgeoftheplatenotlessthan1.5 m bellownormalgroundlevel, connectedtogalvanizedearthlead wire 4 mmdia.bymeansof galvanizedironorsteelbolts , nuts , check nuts andwashers, andconnectedto equipmentsasdirected,includingfunnelwithGI med grade wateringpipe20 mmbore , wiremesh ,charcoalorcokeandcommonsaltinalternatelayersof15 cmcompactedthicknessallaroundtheearthelectrode ,withconcretepitinPCC(1 :3:6)type C-1 , 50 mmthickprecastRCC(1 : 2 : 4)typeB-1 coverslabreinforcedwith8 mmdiadeformedbar15 cm C/Candsuitablehandleof 10 mmdia roundbar,GI medium grade pipe for earth lead protectionincludingnecessaryexcavationearthworkinsoft/loosesoilanddisposalofspoiltoadistancen.exc.50 mandnecessarytestingcompleteallasshownonelectricalplateNo. 3ofMESSSRPart-I and as directed. |
| 93 | S&F LED security light suitable for 35 W LED with pressure di cast housing with epoxy power coated drak graphite grey colour finish , Prismatic ploycarbonate cover with individual LED lenses, IP65 by using 25mm dai GI bracked fixed on wall by means of nuts, botls and clamps. Make : Philips/Havells/Crompton. |
| 94 | M&L Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the concealed to wall/ceiling including one run of 4 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.NOTE : Two runs of single core4 sqmm and one run of 4 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length. |
| 95 | S&F Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC. Make- Legrand or equivalent in Siemens/Schindler. |
| 96 | Supply and fixing rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SP 6 To 32 ampand current carrying capacity in the MCB DB complete with connection testing andcommissioning. Make : Legrand or equivalent in Siemens/Schneider |
| 97 | Supply and fixing rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 32 amp and current carrying capacity in the MCB DB complete with connection testing andcommissioning. Make : Legrand or equivalent in Siemens/Schneider |
| 98 | M&L for sand cushioning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches complete all as specified and directed. Note :-Only Punned layers shall be measured. |
| 99 | Supply and laying reinforced precast concrete cable cover class LV type 1 flaat size 250mmx150mmx40mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge. |
| 100 | Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall with the help of shadel of size 25 Sqmm 4.0 core as required at site. |
| 101 | M & L GI tube light grade for passing through cables under the floor ,along the wall or along the pole of 25 mm bore and fixed to the poles/walls with suitable size of MS clamps and nut and botls/washers etccomplete all as specified and as directed. |