| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-incharge. |
| 2 | In Cement mortar |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering --All work upto plinth level: |
| 4 | 1:3:6 ( 1 Cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 5 | 1:1.5:3 ( 1 Cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 7 | Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 8 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete |
| 9 | 12 mm cement plaster of mix: 13.1.1 1:4 (1 cement : 4 fine sand) |
| 10 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 11 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 12 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade. ( Two or more coats on new work) |
| 13 | P/F UPVC soil ,waste ,rain water and vent pipes including all requisite fittings,jointing of pipes & fittings with solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineeer in charge |
| 14 | 110mm |
| 15 | Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. 10.16.1 Hot finished welded type tube |
| 16 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with |
| 17 | Precoated galvanised iron profile sheets 0.40 mm thick |
| 18 | Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately): |
| 19 | For fixed portion. |
| 20 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 21 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 22 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete |
| 23 | Size of Tile 600 x 600 mm |