Tender For Spl Repair To Bldg No P-154 Otm Accn Of Ge (N) Ambala Cantt; 1 Schedule A Part-I (B/R itmes)Demolition of cement concrete (un–reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete, all as specified and as directed by Engr-in-charge. 2 Providing and injecting emulsion for post construction anti termite treatment using chemical chloropyriphos 20EC conforming to IS 8944 or lmidacloprid 30.50 SC conforming to IS 16131 concentrate along the external wall of buildingbelow concrete or masonry apron using chemical emulsion @ 2.25 litre per linear metre including drilling 12mm dia holes @ 300 mm apart and plugging holes with cement mortar 1:2 (1 Cement 2 Coarse sand) in apron, complete all as specified and directed by Engr-in-charge 3 Providing and injecting chemical emulsion for post construction anti termite treatment using chemical chloropyriphos 20EC conforming to IS 8944 or lmidacloprid 30.50 SC conforming to IS 16131 of soil under existing floorsusing chemical emulsion @ 1 Ltre per hole 300mm apart including drilling 12mm dia holes @ 300 mm apart and plugging holes with cement mortar 1:2 (1 Cement & 2 Coarse sand) to match the existing floor and making good the disturbed sufaces to match with the existing surface, complete all as specified and directed by Engr-in-charge. 4 Providing and injecting chemical emulsion for post constructional anti termite treatment at points of contact of wood work by usingchemical chloropyriphos 20EC conforming to IS 8944 or lmidacloprid 30.50 SC conforming to IS 16131 emulsion in oil or kerosene based solution@ 0.5 litre per hole by drilling 6mm dia holes at a downward angle of45 degree @ 150mm centre to centre and sealing the same and making good the disturbed sufaces to match with the existing surface, complete all as specified and directed by Engr-in-charge. 5 Demolition of cement concrete (unreinforced) of any descriptionand in any position including any type of sunken treatment , roof treatment, PCC padding, lime concrete etc., complete all as specified and directed by Engr-in-charge.Note: All Demolished material / debries will be taken by the contractor out side of thecantonment without any extra cost to the govt,contractor should quote his rate Keeping this Aspect in mind. 6 Material and labour for cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight), complete all as specified and as directed Engr-in-charge. 7 Material and labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as inmass concrete over roof as in padding incl cement slurry @ 3Kg/Per sqm over old RCCsurface, surfacefinished even & smooth without using extra cement. all as specified and directed by Engr-in- charge. 8 Material and labour for, 15 mm thick plaster in cement mortar (1:4) over concrete surfaces of roofs finished even and smooth with WPC @ 3% by weight of cement ( WPC will be measuredpaid seperately) as in roof treatment work, complete all as specified and directed by Engr-in- charge. 9 Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bituminous primer @ 0.40 litre /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temperature and viscosity 70–160 cps over the primer coat with overlap of 100mm at theside and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc. after preparing the surface complete as per standred practice as per manufactures instructions. The vital physical and chemical parameters of the membrane shell be under :–(i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms(ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d–5147)(iii) The laying of membrane shell be got down through the authorised applicator of manufactures of membrane only, complete, all as specified and as directed.(iv)The work shall be carriout at a height upto 12 metre. 10 Material and labour for applying a coat of solar reflective aluminium paint @ 0.11 kg per sqm on APP membrane surfaces, complete all as specified and as directed by the Engineer-in-charge. 11 Material and labour for providing cementconcrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in roof kerbs or mud stops,padding,rounded or chamfered on edges including form work where ever required, complete all as specified and directed by Engr-in- charge. 12 Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches,pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles ,complete all as specified and directed by Engr-in- charge. 13 Material and labour forbrick work with sub class B old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 ,complete all as specified and directed by Engr-in- charge. 14 Material and labour for brick work with sub class -B bricks, in half brick thick walls, built in cement mortar 1:4 straight or curved on plan to any radius, complete all as specified and directed by Engr-in- charge 15 Supply only integral water proofingcompound, complete all as specified and as directed by the Engineer-in-charge. 16 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engr-in- charge. 17 Material and labour for providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternatebays (not exc 2 Sqm each )and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work, complete all as specified and as directed by the Engineer-in-Charge. 18 Material and labour for 25 mm thick Cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in sub base floors, surface fair finished and even and rough to receive floor finishes, complete all as specified and directed by Engr-in- charge. 19 Material and labour forvitrifiedceramicdouble charged light shade tiles, 1st quality,(square/rectangular), 10mm thick, area of each tile exceeding 0.42 sqm andnot exceeding 1.00 sqm as in floor, set and jointed in neat cement slurry and pointed in colouredepoxy groutto match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6for laying floor finishes, complete all as specified and as directed by the Engineer-in-Charge.( Note :- The joints of vitrified tiles shall be 2 to 3 mm thick and will be pointed with epoxy grout ( three part compound ie; Resin , Hardner and filler) . The cost of grouting with epoxy are inclusive in this item and nothing extra shall be admissible in to this account . ) 20 Material and labour forvitrifiedceramic double charged light shade tiles, 1st quality,(square/rectangular), 10mm thick, of same description as of floor tiles in serial item No. 19abovebut 100mm to 200mm heightas in skirting, set and jointed in neat cement slurry and pointed in coloured epoxy groutto match the surface over and including rendering 10 mm thick in cement mortar 1:4, complete all as specified and as directed by the Engineer-in-Charge.( Note :- The joints of vitrified tiles shall be 2 to 3 mm thick and will be pointed with epoxy grout ( three part compound ie; Resin , Hardner and filler) . The cost of grouting with epoxy are inclusive in this item and nothing extra shall be admissible in to this account . ) 21 Material and labour for 10mm thick vitrified coloured paver tiles of size 300 x 300mm in floors etc. set and jointed in neat cement slurry and pointed in colouredepoxy groutto match over and including 15mm thick screed bed in Cement mortar 1 :4, complete all as specified and as directed by the Engineer-in-Charge. ( Note :- The epoxy grout should be three part compound ie; Resin, Hardner and filler . The cost of grouting with epoxy are inclusive in this item and nothing extra shall be admissible in to this account . ) 22 Material and labour for vibratory rubber moulded coloured precast concrete interlocking paver block, any shape and sizeconforming to IS 15658-2006,ISI marked of 60 mm thickness, grade M-35 with grey cement andpigments over and including a layer of sand cushioning, 25 mm thick, complete all as specified and as directed by the Engineer-in-Charge. 23 Material and labour for Non Skid coloured ceramic tiles joint freepremium/1st quality 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured epoxy groutto match over andincluding15mm thick screed bed in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge. ( Note :- The epoxy grout should be three part compound ie; Resin , Hardner and filler . The cost of grouting with epoxy are inclusive in this item and nothing extra shall be admissible in to this account . ) 24 Material and labour for Non Skid coloured ceramic tiles premium/1st quality of same description as of floor tiles in serial item No 23 above but 100mm to 200mm heightas in skirting, set and jointed in neat cement slurry and pointed in coloured epoxy grout to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4, complete all as specified and as directed by the Engineer-in-Charge.( Note :- The epoxy grout should be three part compound ie; Resin , Hardner and filler . The cost of grouting with epoxy are inclusive in this item and nothing extra shall be admissible in to this account . ) 25 Material and labour for glazed ceramic coloured tiles 450x300x7mm thick on vertical surfaces such as dados set and jointed in neat cement slurry and pointed in coloured epoxy groutto match over and including 10 mm thick backing coatin cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.( Note :- The epoxy grout should be three part compound ie; Resin , Hardner and filler . The cost of grouting with epoxy are inclusive in this item and nothing extra shall be admissible in to this account . ) 26 Dismantling stone slab of any description or thickness laid, bedded and pointedin any motar in floors etc, complete all as specified and directed by Engr-in-Charge. 27 Material and labour for Granite (of any type)slab 18-20 mm thick machine cut, bedded and jointed with gray cement slurry and pointed with white cement as in floors/ cooking plateform, with admixiture of pigment to match the shade of granite stone including grindingand polishing complete over and including20 mm thick screed bed in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge. 28 Material and labour for Granite (of any type)slab 18-20 mm thick machine cut , jointed with gray cement slurry and pointed with white cement as in vertical surfaces / dado / skirtingwith admixiture of pigment to match the shade of granite stone indluding grindingand polishing complete over and including 10 mm thick backing coat in Cement mortar 1:4, complete all as specified and directed by Engr-in-Charge. 29 Material and labour for rounding to edges of stone slabboth edge such as in steps, cooking plateformand other similar situtaions withgrinder, complete all as specified and directed by Engr-in-Charge. 30 Material and labour for machine cut kota stone slab flooring 18 to 22 mm thick of size not less than 550mm x 550mm in floor/landing/treads of stairs,set and jointedin neat cement slurrywith greycementmixed withpigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15 mm thick screed bed in Cement Mortar 1:4, complete all as specified and directed by Engr-in-Charge. 31 Material and labour for machine cut kota stone slab flooring 18 to 22 mm thick ( kota stone shall be cut from size not less than 550mm x 550mm) in skirting/risers , set and jointedin neat cement slurrywith greycementmixed withpigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 10 mm thick renderingin Cement mortar 1:4 , complete all as specified and directed by Engr-in-Charge 32 Material and labour for machine cut green marble stone slab flooring 18 to 22 mm thickin floor, window cills,set and jointedin neat cement slurrywith greycementmixed withpigment to match the shade of the slab including rubbing and polishingover and including 15 mm thick screed bed in Cement Mortar 1:6, complete all as specified and directed by Engr-in-Charge. 33 Material and labour for machine cut green marble stone slab 18 to 22 mm thickin skirting/risers , set and jointedin neat cement slurrywith greycementmixed withpigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick renderingin Cement Mortar 1:4, complete all as specified and directed by Engr-in-Charge. 34 Dismantling of Reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed by Engr-in-Charge. (Reinforcement cut to facilitate dismantling) 35 Material and labour for Reinforced cement concrete design mix M-25 using 20mm graded stone aggregate, as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the likedack slab, complete all as specified and directed by Engr-in-Charge. 36 Material and labour for reinforced cement concrete design mix M-25 using 20mm graded stone aggregate, graded stone aggregate as inchajjas, Fins, fascias, louvres, parapets, and railings exceeding 60cm in height, newels, balustrade, and the like, complete all as specified and directed by engineer in charge . 37 Material and labour for formwork to chajjas, fins, louvres, facias including edges for rough finished surfaces of concrete flats, complete all as specified and directed by Engr-in-Charge. 38 Material and labour for formwork to soffits ofsuspended slabs such roof slab, floor slabs, landings and similar work not exceeding 20 centimetre thick (horizontal or sloping) flat for rough finished surfaces of concrete, complete all as specified and directed by Engr-in-Charge. 39 Material and labour for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofsand sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide, for roughed finished surface of concrete, complete all as specified and directed by Engr-in-Charge. 40 Material and labour forTMT steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia, complete all as specified and directed by Engr-in-Charge. 41 Taking down chowkats or frames with shutter areanot exceeding 1.50 Square metre (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish, complete all as specified and directed by Engr-in-Charge. 42 Taking down chowkats or frames with shutter area exceeding 1.50 Square metre andnot exceeding 4.00 Square metre (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish, complete all as specified and directed by Engr-in-charge. 43 Taking down shutters of any description area exceeding 1 sqm and not exceeding 2 sqm each and removing the same from site, complete all as specified and directed by Engr-in-charge. 44 Cutting holes in brick walls built in cement mortar exceeeding half brick thick and not exceeding one brick thick wall for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 (Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall)as required, complete all as specified and as directed by Engr-in-charge. 45 Supply and fixingFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 75 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast of required size and length, complete as per direction of Engineer-in-Charge. 46 Supply and fixing factory made solid PVC moulded door shutters with partical board core 28 to 30 mm thick (styles) with 2, 4, or 6 raised panel design with 2 mm thick plain moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame at site as per specification and drawing , complete, all as specified and as directed by Engr-in-charge. 47 Supply and fixing of factory made single extruded WPC (Wood PolymerComposite) solid door/ window/ Ceosetory windows & other frames/chowkhat of size 100 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardantand fixed in position with mild steel hold fast of required dia and length, complete all as specified and directed by Engr-in-charge.NOTE : - (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensionson plus side shall be acceptable but no extra payment on this account shall be made.(ii) Material manufacture test certificate should be provided before execution of work. 48 Supply and fixing of factory made single extruded WPC (Wood Polymer Composite) solid decorative type moulded ( Jointless ) door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing withfull body threaded star headed counter sunk S.S screws, completeall as per specification & drawing, complete all as specified and directed by Engr-in-charge. 49 Material and labour for Providing and Fixing of windows made of pre-painted steel (Base steel as per IS 513 of 0.58 mm thick “D” Quality galvanized as per IS 277 with Zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for shutter frame should be of 52x25mm and size of flymesh shutter should be of 20x40mm and rebate for Glazed shutter and flymesh shutter with a 20mm provision for Guard bars/Grills. The sections are to be cut to length metre joined with corner bracket. Centre mullion is to be fixed with mullion cap. Shutter brackets with a inbuilt pvc lip to be fixed in a way that the lip overlaps the shutter corners and are not exposed. Handle,stay, 2 nos. of Stainless Steel heavy duty Pivot hinges shall be provided per shutter the windows fitted with 4mm thick plain float/frostedglass with rubber gaskets including fixing the frames in concrete/masonry wall by MS holdfast, Including fixed panel beading section should be of 12x12mm. Outer frame and mullions to have 10mm Square guard bars with 6” (152.4mm) pitch etc., complete for finished item of work.(Make: Elixir Met Form Pvt Ltd. / A2Z Infra Solutions / Urban Space ) 50 Supply and fixing box type using ERW hollow P section ventilators fixed type with glazing barincluding MS grills of square bar 10mm dia @ 100 c/c complete with glazing bars dovetailed or welded, including two coat of synthetic enamel ordinary tint paint over a coat of red oxide primer, complete all as specified and as directed by Engr-in-charge. 51 Material and labour for sheet glass 3.00mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane, complete all as specified and as directed by Engr-in-charge. 52 Supply and fixing mild steel works in bands, straps, supports, stays, bolts, hooks, hold fasts etc, similar articles conforming to Fe-290.Gde-E-165, complete all as specified and as directed by Engr-in-charge. 53 Supply and fixing mild steel door shutter two leaves with frame of 20 gauge MS sheet (all around) and leaves of 21 gauge MS Sheet (all as per godrej pattern) with three way locking arrangement with brass lock with duplicate key and CP handle including two coats of spray painting over a coat or red oxide primer complete fixed in existing cupboard fixed with necessary nuts, bolts including embedded in PCC 1:2:4 (area of opening shall be measured), complete all as specified and as directed by the Engineer–in–Charge. 54 Resecuring or easing & adjusting after taking down shutters of any description area exc 1 sqm and not exceeding 2 sqm each andrefixing in the same opening , complete all as specified and as directed by Engr-in-charge. 55 Supplyand fixingstainless steel wire cloths0.36 mm nominal dia of wire and averagewidth of aperature 1.40 mm and fixed with stainless steelwire staple, complete all as specified and as directed by Engr-in-charge. 56 Supply and fixing 100 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pine including screwing or welding to MS / PVC frame ( as required ), complete all as specified and directed by Engr-in-charge 57 Supply and fixing 150 mm long aluminium handle cast type anodised, complete all as specified and as directed by Engr-in-charge. 58 Material and labour for 2nd class hard wood Small fitting such a brackets of any type ,latch and hinge block , shaped door and window stops and the like including all necessary labours articles not exceeding 200 Cu cm each including 50mm long mild steel cold rolled medium weight but hinge, complete all as specified and as directed by Engr-in-charge. 59 Supply and fixing 150 mm long aluminium anodised barrel tower boltsof extruded section and fixed ,complete all as specified and as directed by Engr-in-charge. 60 Supply and fixing 200 mm long aluminium anodised barrel tower boltsof extruded section and fixed ,complete all as specified and as directed by Engr-in-charge. 61 Supply and fixing 250mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter ,complete all as specified and as directed by Engr-in-charge. 62 Material and labour for galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floorsas in repair, complete all as specified and as directed. 63 Material and labour for galvanised iron tubing 20mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floorsas in repair, complete all as specified and as directed by Engr-in-charge. 64 Cuttingchases to brick wall built in cement mortar, pinning in making good to facing where required and pointing in Cement Mortar 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exceeding 10 cm girth ,complete all as specified and as directed by Engr-in-charge. 65 Supply and fixing 600mmx450mm bevelled edge mirror 5mm thick of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, as in repair, complete all as specified and as directed by Engr-in-charge. 66 Supply and fixing in repair Vitreous china orissa pan squatting pattern 580 X 440mm with integeral foot rests including P or S trap and including PVC low level flushing cistern 10 ltrs capacity and Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, complete all as specified and as directed by Engr-in-charge.Note : The cost of traps, flushing cistern and PVC flush pipes are included in this item. 67 Supply and fixing single pieace water closet wtih PP soft close seat cover, hinges, fixing accessories and accessories set, cistern fittings, S or P Trap complete fixed, as in repair, complete all as specified and as directed by the Engineer-in-Charge. Make : Jaquar Cat Part No ONS-WHT-10853S300UFSM /CERA Cat part No.S1013142 /Hindware Cat Part No.92573 (S-22) 68 Supply and fixingvitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing ofwaste fitting etc., as in repair, complete all as specified and as directed. 69 Supply and fixingsinks with drainage board made out of stainless steel 1mm thick sheet for kitchenincluding plugs, waste pipe, 75 mm diabrass chromium plated coupling including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mmwith bowl size 410mm x 330mm x 160mm, as in repair, complete all as specified and as directed by the Engineer-in-Charge 70 Supply and fixing as in repairfancy type pillar tap of 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and as directed by Engr-in-charge. 71 Supply and fixingas in repair15mm bore cast copper alloy chromium plated angular stop valveswith capstan head, screwed down, high pressure scrwed both ends for iron pipe or for unions, complete all as specified and as directed by Engr-in-charge. 72 Supply and fixing as in repair bib taps 15mm bore fancy type brass chromium plated with long body, wall flanges and capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed by Engr-in-charge. 73 Supply and fixing PVC connections 15 mm sizewith PTMT nuts of length 450 mm, as in repair, complete all as specified and as directed by Engr-in-charge. 74 Supply and fixing brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges as in repair, complete all as specified and as directed by Engr-in-charge. 75 Material and labour for Stainless steel plate rack of size 31 x 30 x 10 of load capacity not less than 30 kg including fixing with stainless stell screws including taking down of old plate rack of any description, complete all as specified and as directed by Engr-in-charge. 76 Supply and fixing in repairStainless steel ( SS 202 grade ) Curtain rod25 mm dia 0.80 mm wall thickness, mild steel, chromium platedincluding ornamental typesupporitng and end brackets as per sample, complete all as specified and as directed by Engr-in-charge. 77 Supply and fixing sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 mm wide with chromiun plated brackets guard and railing 60 cm long as in reapir complete all as specified and as direced by the Engineer–in–charge. 78 Supply and fixingas in repair 100mm bore PVC (SWR) floor trap, plain with chromium plated grating including jointing with solvent cement, complete all as specified and as directed by Engr-in-charge. 79 Supply and fixing in repair CP Soap Dish of size 100mmx100mm as approved Design, complete all as specified and directed by Engr in Charge . 80 Supply and fixing as in repair, water storage tank, 500 ltr capacity, HDPE triple layer, white colour, conforming to IS, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm dia high pressure with polythene float and flynut, screwed and suitable for iron pipe 20 mm bore and including 20mm bore tank nipple & one 20mm GI union at outlet and including dismantling of water tanks and removing from site all as specified in SSR Part–I, complete all as specified and as directed by Engr-in-charge.Note : - The colour of tanks shall be white colour . 81 Cutting into existing manholes for connecting new drains, and making good to pipe and rendering, cutting out existing benching for and forming branch channel( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1 (using 20mm size crushed stone aggregate) smooth finished and reforming benching as required of pipe 100 mm dia,complete all as specified and as directed by Engr-in-charge. 82 Desilting of manhole complete by removing all scum, sludge, silt (both organicand inorganic nature) bymanual labour or mechanical scraper and disposal of the same in closed container at authorized dumping site declared by local administration outside MD landand buried in trenches etc, as in foul condition for any depth, complete all as specified and as directed by Engr-in-charge.Note:- Sludge, scum, silt (both organicand inorganic nature) water shall be disposed off in closed container at authorized dumping site declared by local administration outside MD land. 83 Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables etc. or for shafts, wells, manholes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil, complete all as specified and as directed by the Engineer-in-Charge. 84 Returning filling in including spreading, levelling, watering and wall ramming in layer not exceeding 25 cm, any kind of soil, complete all as specified and directed by Engr-in-charge. 85 Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point ,complete all as specified and as directed by Engr-in-charge. 86 Demolition and breaking up drain pipes and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan–necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed by Engr-in-charge. 87 Supply and fixing 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor or fixed to wall, complete all as specified and as directed by Engr-in-charge. 88 Supply and fixing 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall or in trenches, complete all as specified and as directed by Engr-in-charge. 89 Supply and fixing 110mm bore PVC (SWR) bends of any radius,complete, all as specified and as directed by Engr-in-charge. 90 Supply and fixing 75mm bore PVC (SWR) bends of any radius with access doors, complete all as specified and as directed by Engr-in-charge. 91 Supply and fixing 110mm bore PVC (SWR) juction double (double T) equal are unequal with acces door, complete all as specified and as directed by Engr-in-charge. 92 Supply and fixing 110mm bore PVC (SWR) juction single (Single T) equal are unequal with acces door, complete all as specified and as directed by Engr-in-charge. 93 Supply and fixing asin repair for PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement, complete all as specified and as directed by Engr-in-charge. 94 Supply and fixing as in repair 75 mm bore PVC (SWR), vent cowls including jointing with solvent cement, complete all as specified and as directed by Engr-in-charge. 95 Supply and fixing 110 x 75 mm bore PVC (SWR), reducerincluding jointing with solvent cement, complete all as specified and as directed by Engr-in-charge. 96 Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete, all as specified and as directed by Engr-in-charge. 97 Material and labour for repairing of RCC projection, chajjas, facia, bands, shelves, beams, RCC railing, balcony and similar works by dismantling of loose/ disintegrated portion of RCC at any height and in any sitution / floor (including provn of support,formwork and welding of reinforcement if required with wire mesh of weight 3 kg/ sqm and dubbing/ fillingwith PCC (1:2:4), type B-0, using 12.5 mm graded aggregate,15 to 25 mm thick over and includingapplying cement slurry @ 3 kg/sqm, finished even and smooth to desired shape, complete all as specified and as directed.Note:-(i) Unit rate of this item includes the cost of scaffolding,formwork etc. and nothing extra shall be paid on account of variation in height. (ii) Wire mesh shall be measured and paid for separately 98 Supply and fixing Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcent (Weight per square metre not exceeding 4 Kg),complete all as specified and directed by Engr-in-charge. 99 Material and labour for rendering 15 mm thick(in patches) on brick work or concrete wall surfaces in cement mortar (1:4)including mixing water proofing compound @ 2% by weight of cement or as per manufacturers instruction and finished even and smooth without using extra cement complete, all as specified and as directed by the Engineer-in-Charge. ( Note- The cost of providing WPC shall be included in quoted rate under this item ) 100 Material and labour for rough cast plaster complete as specified in SSR Part–I, clause 14.22 shall consisting of following :– firstly apply under coat in cement mortar 1:3 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel aggregate which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1:1 shall be applied, complete all as specified and as directed by the Engineer–in–Charge. 101 Dismantling of boarding/wall panelling /false ceiling of any description, any thickness including frame/grid work complete all as specified. 102 Supply and fixing of fixing GI OREO Metal Suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sq, both side inclusive) consisting of main I runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross Tof size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using Gl slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm Gl adjustable rods with galvanised bullerily level clips of size 85 x 30 x0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. Gl Metal Ceiling Lay in perforated Tegular edge global whitecolor tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of Gl sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum). including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece complete all as specified and as directed by the Engineer-in-Charge. DEXUNE or Equivalent. 103 Supply and fixing 18mm thick lead free PVC celuka ply ( minimum density 600 Kg/ Cum) of both side plain ofapproved colour other thanwhite colour fixed with stainless steel screws and solvent cement / adhesive to make kitchen / bed rooms cabinet sides, top and bottom and shelves inside the cabinets complete all as per manufacturers specifications/ instructions, complete all as specified and as directed by the Engr-in-charge. 104 Supply and fixing as in repairContinuous (piano) hinges, width of flaps 30mm mild steel, bright finish or electro galvanised, complete all as specified and as directed by Engr-in-charge. 105 Material and labour for coloured vitrified anti-skid matt finished tiles of size 400mmx400mmx11.5 to 12mm thick in floors etc set and jointed in neat cement slurry and pointed in coloured epoxy grout to match over and inculding 15mm thick screed bed in cement mortar 1:4, complete, all as specified and as directed by the Engineer-in-Charge.Note: Design and colour of tiles shall be approved by Garrison Engineer/Engineer-in-charge.The cost of epoxy grout are inclusive in this item . Nothing extra shall be admissible in to this account . 106 Supply and fixing as in repair Stainless Steel grade 304golden/silver colour hollow letters of minimum size 200mm height x 100mm with 25 mm thick raising including grounting in existing granite/marble with suitable sealant/adhesive and stainless steel studs with making good existing surfaces, complete all as specified and as directed by the Engineer -in-Charge. 107 Material and labour for preparation of newly plastered or un-plastered surfaces onwalls, chajjas, roof projection, cornices of brick /concrete surfacesetc. andapplying two coats of cement based paint (white or tinted) over a coat of alkali resistant primer,complete all as specified and as directed by Engr-in-charge. 108 Material and labour for rendering 15mm thick on fair faces of brick or concrete surfacesin Cement mortar 1:6 finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-charge. 109 Material and labour for prepartion of new plastered/ concrete surfaces and applying two coats of water based distemper emulsion over and including one coat of primer and two coats of wall care putty, complete all as specified and directed by Engr-in-charge. 110 Material and labour for preparation of newlyplastered/ unplastered surfaces of brick/ concretewall and applying two coats of white lime wash, complete all as specified and as directed by Engr-in-charge. 111 Material and labour for rendering 05 mm thick on any faces of brick work or concrete ceiling surfaces in cement mortar 1:3 andfinishedeven and smooth without using extra cement,complete all as specified and as directed by Engr-in-charge. 112 Material and labour for preparation of new plastered/ unplastered surfaces of brick/concrete ceiling and applying three coats of white lime wash, complete all as specified and as directed by Engr-in-charge. 113 Complete removal of existing treatment on walls by with mechanical / electrical driven grinders suitable for removal work and scrapping washing rubbing down etc and applying two coats of oil bound emulsionover and includingtwo coats of acrylic based wall care puttywith one coat of primer, complete all as specified and directed by Engr-in-charge. 114 Material and labour for complete removal of existing treatment on ceiling (any number of layers) by scrapping with steel scrappers or any other means, wasing down with water to remove loose particles etc and applying two coats of white lime wash, complete all as specified and as directed. 115 Material and labour for preparation of old decoratedsurfaces onwalls ,chajjas , roof projection , cornices of brick /concrete surfacesetc. andapplying two coats of cement based paint (white or tinted), complete all as specified and as directed by Engr-in-charge. 116 Material and labour forpreparation of old decorated surfaces of walls and applying two coats of white wash, complete all as specified and as directed. 117 Preparation of old painted steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and as directed by Engr-in-charge. 118 Material and labour forpreparation of new steel surfacesof any description, not otherwise described, over10 cm width or girth and applying two coats of synthetic enamel paintover a coat of red oxide primer, complete all as specified and as directed by Engr-in-charge. 119 Material and labour forpreparation of new wooden surfacesof any description, not otherwise described, over10 cm width or girth and applying two coats of synthetic enamel paintover a coat of pink primer, complete all as specified and as directed by Engr-in-charge. 120 Supply and fixing10 mm thick fluted wall panelsprofile designer PVC paneling with panel of width 250mm to 300mm fixed to wall/ceiling with screw and rawel plugincluding PVC beading (U,L section)wherever required, complete all as specified and directed by Engr-in-charge. 121 Material and labour forpreparation of old decorated woodensurfacesof any description, not otherwise described, over10 cm width or girth and applying twocoats of synthetic enamel paint,complete all as specified and as directed by Engr-in-charge. 122 Material and labour for plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork for rough finished surfaces of concrete, complete all as specified and as directed by the Engineer-in-Charge. 123 Material and labour forproviding precast RCC 1:2:4 type B1 using 20mm gradedcrushed stone aggregate as in landings, precast cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weathering, throating, etc. and setting in cement mortar1:4 complete with joints to match, complete all as specified and as directed by the Engineer-in-Charge. 124 Material and labour for plain cement concrete 1:3:6, type C-2 (using 40mm graded mechanically crushed stone aggregate), as in surface channels and drains, complete all as specified and as directed by the Engineer-in-Charge. 125 Material and labour for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, mould, mitred/ stopped end etc., complete all as specified and as directed by the Engineer-in-Charge. 126 Material and labour for PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and as directed by the Engineer-in-Charge. 127 Material and labour for concrete bed in PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate to drain pipes includingpacking under and haunchingagainst the sides of pipes, after they are laid andtested for 110 mm dia pipes, complete all as specified and as directed by the Engineer-in-Charge. (Pipes shall be measured & paid separately). 128 Supply and fixing of 20 mm bore Gun-metal, globe or gate valves with iron wheel head, screwed both ends for ironpipe, as in repair, complete all as specified and as directed by the Engineer-in-Charge. 129 Schedule A Part-II (E/M items)Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etccomplete all as specified and as directed by the Engineer-in-Charge. 130 Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly(boxesshall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally) including provision of new covered plate over sunken box for housing themodular switches , modular socket outlets,modularfan regulators etc.for one light/fan/exhaust fan/bell point controlledby one way switch,complete all as specified and as directedby Engineer-in-Charge. Note :-a) All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid forseparately . 131 Description all as per serial item No.130 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on same board,complete all as specified and as directedby Engineer-in-Charge. 132 Description all as per serial item No.130here-in-before but for one socket outlet 6 Amp with 2.50 sq mm PVC insulated, unsheathedcable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade, ISI marked with multi stranded copperwire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge. Note : (i) Point wiring shall be done in a manner that not more than 04 socket point executed in one circuit.(ii)Each socket point will be measured and paid as per point. 133 Description all as per srl item No 130here-in-before but for one socket outlet 16 Amp with 4.00 sq mm PVC insulated, unsheathedcable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copperwire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.Note : (i) Point wiring shall be done in a manner that not more than 01 socket point executed in one circuit.(ii) Each socket point will be measured and paid as per point. 134 Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. 135 Supply and fixing of modular switch 1 module, single pole, one way 16 Amps flush type, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. 136 Supplyand fixing of modular bell push 6 Amp, 1 way, 1 module, 230 volts complete all as specified and as directed by the Engineer-in-Charge. 137 Supply and fixing of modular socket outletmultipin combined,6 Amp, one way, two module, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. 138 Supply and fixing ofmodular socket outletmultipin combined, (6pin), 6/16 Amp, one way, two module, 230 voltscomplete all as specified and as directedby Engineer-in-Charge. 139 Supplyand fixingas in repairelectronic Fan regulator, modular 100 watts, 1 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep, complete, all as specified and as directed by the Engineer-in-Charge. 140 Supply and fixing ceiling rose surface type 2/3 terminalpolycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge. 141 Supply and fixing in repair,LED batten fitting 10-12 watts, 2 feet, aluminium housing with electronic drivercool/warm typeindustrial model complete,connecting with copper conductor flexible cablefrom ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LUMILINE+ BS10WLED865SPCSS of make Havells or equivalent in make given in Appx B. 142 Supply and fixing in repairLED batten fitting 18-20 watt, 4 feet, aluminium housing with electronic drivercool/warm typeindustrial model complete,connecting with copper conductor flexible cablefrom ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LUMILINE+ BS20WLED865SPCSS of make Havells or equivalent in make given in Appx B. 143 Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA B curve including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.Cat part No.811955 of make Indo Asian or equivalentin make given in Appx B. 144 Supply and fixing MCB SP, 6-32 Amps, 240 volt,10 KA ,B curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge. Cat part No 811008 to 811015 of make Indoasian or equivalent make given in Appx B. 145 Supply and fixing MCB SPN 32 Amps, 240 volt,10 KA ,B curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.Cat part No 811035 of make Indoasian or equivalent make given in Appx B. 146 Supply and fixing sheet metal enclosureVertical triple pole & neutral(VTPN) IP-54 including MCCB 63 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and includinglugs/thimbles duly crimped for connectionincluding making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811882 + 830020 of make Indo Asian or equivalent make given in Appx B. 147 Supply and fixing sheet metal MCB DB SPN8 way with 200 Amps rated bus bar single pole and neutral withdouble door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811826 of make Indo Asian or equivalent make given in Appx B. 148 Supply and laying as in repair sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI markedmulti stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium gradeISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge.Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length. 149 Supply and laying as in repair sub main wiring with four run of 10 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 10 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI markedmulti stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and includingPVC conduit medium gradeISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge.Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.(ii) Four runs of cable and one run of PVC conduit shall be measured and paid as one unit length. 150 Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earthstrip 25 x 3mm thickby means of bolts, nuts, check nuts and washers of galvanised iron.Earth stripprotected by GI pipe 32mm bore(medium grade) and connected to earthing test pointas directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/cboth ways with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testingas in repair complete all as directed by Engineer-in-Charge and earth testing on completion . 151 Taking down serviceable tube lights / mirror light / ceiling light any type during execution of work and refixing the same after complition of work complete all as specified and directed by the Eng-in-charge. 152 Supply and fixing GI/MS (terminal boxes) rectangular block with earth dolly duly painted internally and externally with two coats of anti corrosive paint over a coat of redoxide primer including provision of new 3 modular cover plate with support frame over sunken box fixed with brass screw and cup washer for mounting, modular switches, sockets outlets, fan regulator etc. complete all as specified and as directed by the Engr-in-charge. 153 All as per above item No. 152 but new 4 module cover plate with support frame, complete, all as specified and as directed by the Engr-in-charge. 154 All as per above item No. 152 but new 6 module cover plate with support frame, complete, all as specified and as directed by the Engr-in-charge. 155 All as per above item No. 152 but new 8 module cover plate with support frame, complete, all as specified and as directed by the Engr-in-charge. 156 All as per above item No. 152 but new 12 module cover plate with support frame, complete, all as specified and as directed by the Engr-in-charge. 157 Taking down serviceable distribution board any way ( SPN DB / VTPN DB) any type alongwith MCB SP / SPN / MCCB during execution of work and refixing the same after complition of work complete all as specified and directed by the Eng-in-charge. 158 Supply and fixingLED flat panel 2 x 2 size fully difused surface/ recess mounted fitting (grid/ gypsum type)36-40 watt , 5700K,warm/cool whitewith powder coating and CRCA front cover including framewith provision ofPVC flexible copper conductor cable from ceiling rose to light fitting as in repair complete all as specified and as directed by the Engr-in-charge.Cat part No.VENUSNEO2X2PLR36WLED857G2 of make Havells or equivalentin make given in Appx B. 159 Note:-Amount of credit ofRs.72,672.00for retrieved materials is mentioned in Schedule of Credit Page No. 123 & 124. of tender documents in pdf form which will be deducted offline while acceptance of tender.