| 1 | Earthwork in excavation by mechanical means (Hydraulic excavator ) overareas (exceeding 30cm in depth,1.5min width as wel las 10sqm on plan) including getting out and disposal ofexcavated earth lead upto 50m and liftup to 1.5m,as directed by Engineer-in-charge, All kind of soil. |
| 2 | Earthwork in excavation by mechanical means (Hydraulic excavator ) overareas (exceeding 30cm in depth,1.5min width as wel las 10sqm on plan) including getting out and disposal ofexcavated earth lead upto 50m and liftup to 1.5m,as directed by Engineer-in-charge, Hard Rock (BP) |
| 3 | Earthwork in excavation by mechanicalmeans in foundation trenches or drains (not exceeding1.5 min width or 10sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m, All kind of soil. |
| 4 | Earthwork in excavation by mechanicalmeans in foundation trenches or drains (not exceeding1.5 min width or 10sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m, Hard Rock (BP) |
| 5 | Stone Soling Hand Packed. Complete job. |
| 6 | Providing and laying cement concrete (M-7.5) 40 mm nominal size and curing complete. |
| 7 | Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mmnominal size) derived from natural sources : 3 graded stone aggregate 20 mmnominal size derived from natural sources incl all carriages from source to site. |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Hot Rolled Deformed Bars incl. all carriages from source to site complete job. |
| 9 | Centering, shuttering and propping including removal of Form Work. |
| 10 | Providing and fixing up to floor five level precast cement concrete solid block of M-10, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete |
| 11 | Cement concrete flooring1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate) finished 40 mm thick with 20 mm nominal size stone aggregate incl carriages. |
| 12 | Providing woodworkinframes of doors,windows,clerestory window and otherframes,wrought framed and fixed in position with hold fast lugs or with fasteners of required dia length (holdfast lugs or dashfastener shall be paid separately). Second class kail wood |
| 13 | Providing and fixing panelled or panelled and glazed shutters for doors,windows andclerestory windows fixing with but thingesof required size with necessary screws,excluding panelling which will be paid for separately,all complete asper directionof Engineer-in-charge.(Note:-Butt hinges and necessary screw shall be paid separately).2nd class kail wood. |
| 14 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, 4.00 thick |
| 15 | Applying priming coatWith ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 16 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 17 | 20mm thick cement plaster of mix 1:4(1 cement : 4 fine sand) including all carriages from source to site of work complete. |
| 18 | Providing and applying white cement based putty of average thickness 2 mm of approved brand and manufacture , over the plastered wall surface to prepare the surface even and smooth complete. |
| 19 | Distempering with 1st quality acrylic distemper, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour two coats. |
| 20 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieveeven shade and colour two coats. |
| 21 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position Budloo / Fir wood |
| 22 | providing and fixing noty plywood of 6mm of approved brand as directed by site engineer. |
| 23 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 24 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete |
| 25 | Proving and fixing of water closet squatting pan (Indian type WC pan ) with 100mm PVC P trap 10 litre low level PVC flushing cistern including flush pipe ( of approved make) manually controlled device (Push Button)with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. Long Pan pattern white vitreous china WC pan of size 580 mm.1 sets |
| 26 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 U V stabilized & anti - microbial fusion welded, having thermal stability for hot& cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Chajge. (Concealed work including cutting chases and making good the walls etc.,) PN-16 Pipe, 25 mm OD (SDR-7.4) |
| 27 | PN-16 Pipe, 32 mm OD (SDR-7.4) |
| 28 | PPR Union 25mm |
| 29 | PPR Union 32mm |
| 30 | Bal valve 32mm dia (brass) |
| 31 | plain elbow and socket 25mm |
| 32 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps. |
| 33 | Angle cock 32mm dia |
| 34 | Bib Cock 20mm dia (Brass) |
| 35 | puff tank |
| 36 | Proving and fixing soil , waste and vent pipes 100mm dia pvc |
| 37 | 75mm dia pvc |
| 38 | Providingand fixing of plain bends of required degree 100mm dia |
| 39 | 75mm dia pvc |
| 40 | providing anfd fixing door and window fixtures, Handle aluminium 6 inch |
| 41 | Handle Almunium 5 inch. |
| 42 | T-BOLT almunium 4 inch |
| 43 | T-BOLT Almunium 6inch. |
| 44 | Aldrops Almunium 12 inch. |
| 45 | Aldrops Almunium 8 inch. |
| 46 | Hinge 4 inch |
| 47 | Box aldrop |
| 48 | Providing and Laying cement concrete M 10 grade with 20 mm nominal size of stone aggregate includingcost of centring and shuttering all work upto plinth level |
| 49 | Providing hoisting and fixing trusses/purlins/rafters /posts/post plates or like components of 1st class budloo/fir wood including cost of screws etc complete |
| 50 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diametre with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m3 |
| 51 | 37 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws with ist class kail wood complete job. |
| 52 | carriage of sand/aggregate including loading unloading complete job by MT 20km. |
| 53 | carriages of cement /steelfrom source to site including loading , unloading and stacking complete job by MT 20km |
| 54 | exavating, supplying and filling of local earth (includingroyalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. job |
| 55 | Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Channel, with modular switch, modular plate, suitable GI box and ear thing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 56 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC channel as required,2X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire:- |
| 57 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 58 | 2 X 10 sq. mm + 1 X 2.5 sq. mm earth wire |
| 59 | Supplying/installation//testing and commissioning of (08 W) LED Surface panel round shape with complete accessories |
| 60 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a) 1 or 2 Module (75mmX75mm):- |
| 61 | b) 6 Module (200mmX75mm):- |
| 62 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requireda) 5/6 A switch |
| 63 | 15/16 A switch |
| 64 | 3 pin 5/6 A socket outlet |
| 65 | 6 pin 15/16 A socket outlet |
| 66 | indicator Lamp |
| 67 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including ear thing etc. as required. (But without MCB/RCCB/Isolator)a) 16 way |
| 68 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requireda) Single pole 6A, SP MCB |
| 69 | Single pole 16A , SP MCB |
| 70 | Double pole 32A, DP MCB |
| 71 | 32A ,DP Changeover switch |
| 72 | Providing and fixing M.S. grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 73 | Providing and fixing of RDD sign board (3\".0 x 2,.6\") with angle iron and painting, writing complete job. |