}

Tender For Repairing And Rennovation Work Of Ittup Building At Lucknow - Training Building 2 Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning Thesurface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres L, lucknow-Uttar Pradesh

Uttar Pradesh Small Industries Corporation Limited has published Tender For Repairing And Rennovation Work Of Ittup Building At Lucknow - Training Building 2 Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning Thesurface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres L. Submission Date for this Tender is 28-04-2025. Building Work Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

48750880
Corrigendum : Tender For Repairing And Rennovation Work Of Ittup Building At Lucknow - Training Building 2 Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning Thesurface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres L
Open Tender
Indian
Uttar Pradesh
Lucknow
28-04-2025

Tender Documents

Tender Details

Tender For Repairing And Rennovation Work Of Ittup Building At Lucknow - TRAINING BUILDING 2 Dismantling old plaster or skirting raking out joints and cleaning thesurface for plaster including disposal of rubbish to the dumping ground within 50 metres lead 3 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 4 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 5 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge 6 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) 7 Providing and laying integral cement based water proofing treatmentincluding preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations 8 Applying a slurry coat of neat cement using 2.75 kg/sqm ofcement admixed with water proofingto IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height includingcleaning the surface before treatment.compound conforming 9 Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerincharge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerincharge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs 10 After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge 11 Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. 12 The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 13 With average thickness of 120 mm and minimum thickness at khurra as 65 mm 14 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.. 15 Finishing walls with Acrylic Smooth exterior paint of required shade : 16 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 17 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete 20 mm cement plaster of mix1:4 (1 cement: 4 coarse sand). 18 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area 3 sq. metres and below 19 Providing and fixing factory made uPVC glazed/wire mesh windows/dours comprising of lead free ufVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded proliles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 1260H in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 Imm dia with countersunk head, comprising of matching polyamide PAG lerade sleeve for fixing frame 20 Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). 21 Fly proof stainless steel grade 304 wire gauge with 0.5 mmdia. wire and 1.4mm wide aperture with matching wood dia. wire and 1.4mm wide aperture with beading 22 TRAINING BUILDINGREPAIRING OF RAIN WATER PIPE 23 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm 24 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110MM 25 Providing and fixing on wall face unplasticised - PVC moulded 26 Bend 87.5° 27 110 mm bend 28 Shoe (Plain) 29 110 mm Shoe 30 Providing and fixing to the inlet mouth of rain water pipe cast irongrating 15 cm diameter and weighing not less than 440 grams. 31 Making khurras 45x45 cm with average minimum thickness of 5 cmcement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarsesand) and a coat of neat cement, rounding the edges and makingand finishing the outlet complete. 32 INTERNAL PLUMBING WORK 33 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests 34 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever 35 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 36 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern 37 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 38 Semi rigid pipe 39 32 mm dia 40 40 mm dia 41 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 42 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250 mm 43 Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38 mm single piece moulded with height of270 mm, effective length of tail pipe 260 mm from thecentre of the waste coupling, 77 mm breadth with 25 mmminimum water seal, weighing not less than 263 gms 44 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms 45 Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length15 mm nominal bore 46 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore 47 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 48 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore 49 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter 50 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:893115 mm nominal bore 51 RAIN WATER SUPPLY 52 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 53 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round. pipes including bed concrete as per standard design : 100 mm diameter 54 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 55 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion 56 Bend 87.5° 57 110 mm bend 58 Shoe (Plain) 59 110 mm Shoe 60 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 61 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete 110mm 62 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete 63 INTERNAL WATER SUPPLY 64 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls 65 25 mm nominal dia Pipes 66 50 mm nominal dia Pipes 67 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall etc.. 68 20 mm nominal dia Pipes 69 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 70 20 mm nominal dia Pipes 71 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 72 25 mm nominal bore 73 50 mm nominal bore 74 Providing and fixing brass stop cock of approved quality : 75 20 mm nominal bore 76 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 77 SANITARY INSTALLATIONS & C.P FITTINGS 78 Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming iw (HSN CODE: 3917) Type B Including jointing with seal ring. (1) Double socketed pipes. 79 a) 110mm dia P.V.C. pipe 80 b) 90mm dia P.V.C. pipe 81 Providing & tixing UPVC Hoor trap of self cleansing design with CP Jali complete in all respects. (Make: Supreme / Finolex/Prince) 82 P-Trap type Floor Trap 110 x 90 mm 83 Providing and fixing terminal guard. 84 a) 110mm 85 Providing and fixing on wall face unplasticised -PVC moulded fittings/accessories fur unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion 86 110mm bend 87 90 mm bend 88 Coupler 89 110mm 90 90mm 91 Single tee with door 92 90x90x90 mm 93 110x110x110 mm 94 Providing and rixing C.P. prass I wo-way angie! valve for EWC points & for fixing Ablution Health rauct of approved quality conforming to15 mm nominal bore 95 Providing and fixing clean out plug 110 mm dia. 96 Providing and fixing on wall face unplasticised-Rigid PVC pipes conforming to 15: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 160mm dia Under floor 97 Providing and fixing pvc Inlet fitting with 2 inlets 80 mm size fabricated from 110 mm dia PVC pipes(approx. iength=150mm to 300mm) and rixed to PVC trap with joint and set in cement concrete jas per standard drawing complete 98 BOUNDARY WALL 99 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. DSR(2.8.1) 100 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)DSR(4.1.8) 101 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 102 Cement mortar 1:4 (1 cement : 4 coarse sand)DSR(6.1.1) 103 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes. 104 Cement mortar 1:4 (1 cement : 4 coarse sand)DSR(6.4.1) 105 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 106 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)DSR(5.1.3) 107 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 108 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)DSR(5.2.2) 109 M.S. or iron work in plain work such as reinforcement.A/R 110 12 mm cement plaster of mix : 111 1:4 (1 cement: 4 coarse sand)DSR(13.4.1) 112 Finishing walls with water proofing cement paint of required shade : 113 New work (Two or more coats applied @ 3.84 kg/10 sqm)DSR(13.44.1) 114 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.DSR(10.2) 115 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufactureDSR.(13.48.3) 116 5% Departmental Charges

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 25-04-2025 DATE EXTEND Date 28-04-2025

Key Value

Document Fees
INR 2965 /-
EMD
INR 125500.0 /-
Tender Value
INR 1.25 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail