Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-05-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 15-05-2025 |
| Sl. No. | Item Description |
| 1 | Taking down Chowkhat or frames not exceeding 1.5 Sqm each with shutters(Without taking off shutters from the frames complete all as specified and as directed. |
| 2 | All as per item 1 above but exceeding 1.5 Sqm but not exceeding 4 Sqm each `complete all as specified and as directed. |
| 3 | S&F size of frame 125 x 60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed. |
| 4 | S&F Factory made box type steel window with pintal hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07. |
| 5 | S&F Factory made box type steel window with pintal hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handle and withoutglazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEJZ/TD-06/07 & CEJZ/TD-07/07. |
| 6 | M&L for 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 7 | M/L 35mm thick 2nd class hard woodGlazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(a) complete all as specified and as directed. |
| 8 | S & F,Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 9 | S&F Factory made solid panel pvc doorshutter 30 mm thick (style) con-sisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be cov-ered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement suppling & fixing at site as per specification and drawing complete all as specified and directed. |
| 10 | S&F in repairsfor Draperly rod /Harrison rails of CP of 20mm dia with fixing brackets , stops, rollers and ringsetc complete all as specified and as directed. |
| 11 | Hacking out old broken glass of any thickness size or description from wooden frames or metal frames fixed with wooden beads/ putty and providing and fixing new ones complete all as specified and as directed.. |
| 12 | S&F in repairs, galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed... |
| 13 | S&F in repairs Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5sqm in each pane upto 10 m high bldg complete all as specified and as directed. |
| 14 | M&L for sheet glass 3mm thick ordinary quality, pin headed type and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 15 | S&F mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 18mm, fixed with tinned tacks or galvanized wire staplescomplete all as specified and as directed. |
| 16 | Supply & Fixing150 mm Aluminium handles, cast type, anodised complete all as specified and as directed. |
| 17 | S & F 200 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed. |
| 18 | S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed complete all as specified and as directed. |
| 19 | S&F in repairs mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed. |
| 20 | Taking down cement plaster on brick walls including raking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 21 | M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement complete all as specified and as directed.. |
| 22 | M&L for rendering 15mm thick in CM 1:4 other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed |
| 23 | M & L rendering 5 mm thick in cement mortar 1:3 on fair faces of brick or concrete work even and smooth without using extra cement in ceiling complete all as specified and as directed.. |
| 24 | M&L for preparation of new plastered or un plasteredsurface of walls including cornices, pilasters etc and applying two coats of cement base paint incl primer complete all as specified and directed. |
| 25 | M/L for 2 mmthick Birla white putty/JK white wall care putty on walls complete all as specified and as directed. |
| 26 | M&L for Preparation of old decorated surfaces by washing, scrubbing down, and applying two coat of oilbound distemper on walls.all as specified and directed |
| 27 | M&L for Preparation of old decorated surfaces and appplying one coat of white wash on walls, cornices etc. complete all as specified and directed. |
| 28 | All as per item No. 27 belove but on ceiling complete all as specified and directed. |
| 29 | M&L for preparation of oldsurfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying one coat of synthetic enamel paint in any tint complete all as specified & directed. |
| 30 | M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint in any tint all as specified and directed |
| 31 | M&L for preparation of old decorated surfaces of walls including cornices, pilasters etc (plastered or unplastered surfaces) andapplying one coat of cement base paint complete all as specified and directed. |
| 32 | M&L for applying two coats of oil bound distemper on new plastered surfaces of walls including preparation of surface complete all as specified and directed. |
| 33 | M&L for Preparation of plasterded or un plasterednew surfaces of ceiling and applying twocoat of white wash completeall as specified and directed. |
| 34 | M&L for preparation of newsurfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying two coat of synthetic enamel paint over a coat of redoxide on new surfaces in any tint complete all as specified and as directed. |
| 35 | All as per item No. 34here in before but applying two coats of synthetic enamel paint over a coat of pink wood primer on new wooden surfaces complete all as specified and directed |
| 36 | Demolition, Cement concreteof any description and in any position not otherwise specifically provided for complete all as specified and as directed . |
| 37 | M & L for cement concrete 1:3:6 type C-2, 75 mm thick using 40mmgraded stone aggregates as in plinth protection finished fair and even complete all as specified and directed |
| 38 | M & L for screed bed or bedding layer of mortar 15mm thick in CM 1:4 for laying floor finishes complete all as specified and directed. |
| 39 | M & L for chequered cement concrete tiles of Size 20cmx20cmx25mm thick any description jointed and pointed in neat cement slurry in floors with grey cement and pigmentcomplete all as specified and directed. |
| 40 | M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed. |
| 41 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, fascias, fins and similar works complete all as specified and directed. |
| 42 | M&L forreinforced cement concrete (nominal mix) 1:2 :4 type B1 using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves Chajjas and the like complete all as specified and directed. Note :- Reinforcement & formwork shall be measured and paid for separately. |
| 43 | S&F TMT MS bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia as complete all as specified and directed |
| 44 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete complete all as specified and directed. |
| 45 | Racking out of cement joints/pointing of bricks work or brick tiles laid flat in floor surface,chanels,roofs etc complete all as specified and as directed. |
| 46 | M&L for Flush pointing to brick tiles / tarracing tiles laid flat on roofs in cement mortar 1:3 complete all as specified and as directed |
| 47 | Demolition of cement concrete (unreinforced) of any description and in any position including taking out water closet Indian type/ EWC and removal of lime concrete bed, \"P\" or \"S\" trap and cleaning the sunken portion complete all asdirected. |
| 48 | M&L for water proofing treatment to RCC sunken floor including wall comprising with the following course of treatment/ specifications form bottom to top:-(a) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.6 kg per sqm over a coat of bitumen primer @ 0.40 ltr per sqm including preparation of roof surfaces complete all as specified and as directed.(b) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as directed.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer\"s instructions.(ii) A minimum overlap shall be not to be less than 150mm ofpolymeric membranes and sealed all overlaps and joints as manufacturer\"s instructions.(iii) All CI/PVC traps in sunken slabs to be enclosed with PCC 1:1.5:3(min 15 cm) all round. |
| 49 | M&L for 15 mm thick rendering over concrete surface of sunken floorin CM 1:3 on wall as well as sunken floor finished even and smooth without using extra cement using WPC complete all as specified and directed. |
| 50 | S&F PVC(SWR) pipes 40 mm bore including fixing to walls as in spouts of sunken portion complete all as specified and directed. |
| 51 | M & Lcement concrete type D-2, 1:4:8, using 40mm graded aggregate as in fillings for sunken portionand mass concrete complete all as specified and directed. |
| 52 | S&F in repair Vitreous china squatting pan, Orissa pattern, size 580x440mm white/ coloured with integral foot rests including flus pipe and connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified. |
| 53 | S&F 10 ltrs capacity PVC valveless syphonic action type flushing cistern low level with inlet ball valve float and dual fluash type complete all as specified and directed. |
| 54 | S&F in repairs for 15mm dia of pipe bib taps cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 55 | S& F in repairs Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as spfd & directed. |
| 56 | S & F in repairs Urinal flat back vitreous china (White), of size 465 x 365 x 265 mm with grating, union for discharge pipe, spreader & 40mm dia PVC waste pipe upto floor trapcomplete all as specified and as directed. |
| 57 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 58 | M&L for coloured Glazed ceramic tiles in vertical surface 300x 200x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick CM (1:4) backing coat complete all as specified and directed. |
| 59 | M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick CM (1:4) screed bedcoat complete all as specified and directed. |
| 60 | S&F in repair 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I complete all as specified and as directed. |
| 61 | Dismantling of brick tiles single layer laid on roof jointed & pointed in cement mortar complete all as specified and as directed. |
| 62 | Demolition/taking out mud from the roofs, any thickness, including plastering and leaping etc including removing rubbish upto 500 mtr from the site complete all as specified and as directed |
| 63 | M&L for rendering 10 mm thick in CM (1:4) mixed with integral water proofing compound as per mfg instr over the padding concrete while still the concreteis still green, complete all as specified & directed.(For roof treatment items only) |
| 64 | M&L for water proofing treatment to roof surface includingparapet wall comprising with the following course of treatment/ specifications form bottom to top:-(a) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm over a coat of bitumen primer @ 0.30 ltr per sqm including preparation of roof surfaces complete all as specified and as directed. (b) One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by torced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer\"s instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise ofpolymeric membranes respectively and sealed all overlaps and joints as manufacturer\"s instructions.(iii) The whole works shall be executed by the authorised company applicator. |
| 65 | M & L for Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set and jointed in neat cement slurry over 15 mm thick screed in cement mortar (1:4) and pointed in neat cement mixed with pigment to match the shade of tiles,complete all as specified and as directed. |
| 66 | M&L for Cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in roof padding complete all as specified and as directed. |
| 67 | M & L for applying bond coat of epoxy bonding agent & cement in 1:1 ratio for bonding old and new concrete on damaged surfaces applying polymer modified mortar in CM 1:3 including mixing of polymer latex additives upto 60mm thickness (Chajjas fins, border etc)(i)Qty of ploymer to be used 15% by weight of the cement. (ii)Use of electrical mixer to get the homogeneous dough on bond coat surfaces.(iii)To achieve required thickness repear this step after 24 hrs as required.(iv) Keep the surfaces moist using water forg for 5 to 7 days etc complete all as specified and as directed.(v)The rate for necessary scaffolding for building height up to 24 meters are included in the quoted rate, nothing extra shall be admissible on this account. Bidder are requested to quote their rate accordingly. Complete all as specified and directed by Engineer-in-CHarge. Make : - Epoxy bonding agent shall be Krishna, Dr Fixit, MC Bauchemie and M/s Cemistik, Sika as directed. |
| 68 | S&F in repair 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floor complete all as specified and directed. |
| 69 | S&F in repair 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to floor complete all as specified and directed. |
| 70 | S&F of 110mm dia PVC (SWR) bends complete all as specified and directed. |
| 71 | S&F 75mm PVC(SWR) bends any radius with acess door complete all as specified and directed |
| 72 | S&F of 75mm dia PVC (SWR) Vent cowl complete all as specified and directed. |
| 73 | S & F 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 74 | S&F in repairs for 75mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and directed. |
| 75 | S & F 15mm bore GI tubes, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors including cutting chases, pinning in making good facing where required and pointing in cement mortar 1:3 to ends or edges for concealed water tubing used in brick wall and incl taking up or down existing steel water tubing, 15mm bore alongwith connections fixed/laid in any situation, complete all as specified and as directed. |
| 76 | All as per item above 75 herein before but 20 mm bore tubing complete all as specified and directed. |
| 77 | M&L for Machine cut kota stone slab flooring 18- 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20mm thick screed bed in CM 1:3 complete all as specified and directed. |
| 78 | M&L for Machine cut kota stone slab flooring 18- 20mm thick in riser of steps, skirting,dadoand pillar over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 10mm thickbacking coat in CM 1:3 complete all as specified and directed. |
| 79 | Taking down carefully existig copper / alumn point wiring for light / fan / bell / socket 5/15 Amp points complete withfitting and fixtures such as switches, sockets, c/ rosess, holders and bracket fittings with battens / conduits / wires,T/L fittings and making good the disturbed surfacesof walls and roofs etc.and to match with existing colour complete all as specified and directed. |
| 80 | Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB\"s (single phase or three phase) of any capacity all as specified and directed. |
| 81 | Taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing complete all as directed and specified |
| 82 | S&FPoint wiring complete with 1100 volts grade PVCFRLSinsulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets, sizes for mounting switch/sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed,stranded (Green colour) connected to common earth dolly complete all as specifiedforfollowing : (a)One light/fan/bell/Bldg security light point controlled by one single pole one way switch. |
| 83 | (b) One 3 pin 5 Amp socket outlet point controlled by one switch on Independent board. complete all as specified and as directed. |
| 84 | (c) One 3 pin 5 Amp socket outlet point controlled by one switch on sameboard. complete all as specified and as directed. |
| 85 | All as per item No. 82 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cable. complete all as specified and as directed |
| 86 | All as per item No. 82 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 4.0 Sqmm PVC insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 4.0 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cable. complete all as specified and as directed |
| 87 | S&F 6 amps, single pole, one way switch urea back piece (IP20), 240V, 50Hz, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 88 | S&F Switch piano flush type 20 amps, single pole one way, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 89 | S&F 6 Amps Socket 2 in 1, Urea backpiece (IP20), white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 90 | S&F Socket outlet, UNI, 2 in one10 Amps & 20 Amps, white in colour, duly ISI markedcomplete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 91 | S&F Ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals dulyISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 92 | S&F batten holder (with metal ring), 240 volts, 50 Hz, 6A, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor/ Cona/ Plaza. |
| 93 | S&F rotary stepped type electronic fan regulator for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 100W, deluxe, white in colour, duly ISI marked complete all as specified and as directed. Make- Anchor/ Cona/ Plaza. |
| 94 | S&F 20W, 6500 K, 4 feet LED Square tube light fitting, energy efficient fixed to wall/ ceiling etc complete all as specified and as directed. Make- Crompton/ KCSAD/ Bajaj/ Havells |
| 95 | S&F LED bulb of 9 watt, B22, 6500K all as specified and directed. Make- Crompton/ KCSAD/ Bajaj/ Havells |
| 96 | S&F LED sleeky bldg street light (Lens) fitting of 35 watts, 6000K, including GI bracket bend to shape made out of GI pipe light grade of 25 mm, size up to 1.2 mtr long etc complete with MS clamps made of 25x3mm MS plate, duly painted with two coats of aluminium paint with nuts/ bolts/ washers and all fixing arrangements to wall/ pole, including connecting up with 2 core copper flexible wire of size 23/00.0076 all as specified and directed. Make- KCSAD, Cat Part No. KDST35 or equivalent in Philips/ Bajaj/ Havells. |
| 97 | S&F Factory made three phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 240/415V, 50Hz supply, VTPN DB, partly immersed in wall, including of MCCB 4 pole adjustable thermal & fixed magnetic type 100 Amps, 50Hz, 415 Volts with rupturing capacity 16 KA and making good distrubbed surfaces with matching colour, complete all as specified and as directed. Make- HPL/ INDOASIAN/ BENLO/ HAVELLS |
| 98 | S&F Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 8 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and as directed. Make- HPL/ INDOASIAN/ BENLO/ HAVELLS |
| 99 | S&F MCB SPN, 40A - 63Amps, 240 volts, \"C\" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning complete all as specified and as directedd. Make- HPL/ INDOASIAN/ BENLO/ HAVELLS |
| 100 | S&F MCB SP, 6A-32 Amps, 240 volts, \"B\" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning complete all as specified and as directed. Make- HPL/ INDOASIAN/ BENLO/ HAVELLS |
| 101 | M&L for Sub main wiring with two single core 2x6 sqmm FRLS insulated and unsheathed stranded copper conductoralongwith earth wire 6.0 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed (Two runs cable and one number earth wire and suitableFRLS conduit shall measured together as unit length). |
| 102 | S&F exhaust fan heavy duty with louvers complete of sweep size 300mm, 900 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and as directed. |
| 103 | Cutting holes making good the distributed surface, grouting nuts for fixing of Exhaust fans complete all as specified and directed. |
| 104 | Fixing or hanging only ceiling fans height upto 3mtr to 5 mtrs ceiling height of bldg including three core FR PVC Insulated & overall round sheathed flexible with PVC, colour of cores are Red, Black & Yellow/ Green is for earthing. Sheath colour is Black of cable size 23/0.0076 complete all as specified and as directed. Note : Ceiling fans obtained/ taking down from item Sr No. 79 as above |
| 105 | Earthing complete with galvanized steel plate elecrode of size60 cm x 60cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to sxposed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009). |
| 106 | Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire. complete all as specified and as directed |
| 107 | S&F XLPE insulated, armoured, 1100 volts grade, heavy duty cable of size 25 Sqmm nominal cross section, 4 core, aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing with double compression copper stain less steel gland at DBs and testing, complete all as specified and as directed. Make-Gloster/ Havells/ Finolex/ Universal Cables |
| 108 | Excavation in trenches in soft/loose soil not exceeding1.5 metre wide and not exceeding 1.5 metre deep and not exc 10 Sqm on plan,for laying of cable and getting out, complete all as specified and as directed. |
| 109 | M&L Dry and clean fine sand for cable cushioningto underground cable protection, complete all as specified and as directed. (Excavation and earth work measuredseparately). Note- Punned down thickness shall be measured. |
| 110 | S&F Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable complete all as specified and as directed. (Excavation and earth work measured separately). |
| 111 | Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as specified and as directed. |
| 112 | Removal of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as specified and as directed. |
| 113 | S&F Mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles/walls, laid under floor/road crossings, complete with and includingclamps socket & elbow etc complete all as specified and as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail