Electrical work in special repair of 04 absorption tanks of type I near H compound in Basti district (A block); 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core (multistranded) cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core(multistranded) cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 3 Supplying and fixing of 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 4 Supplying and fixing brass batten/ angle holder including connection etc. as required. 5 Supplying and fixing of piano type 5/6 amps switch and/3 pin 5/6 amps socket on the existing switch box/ cover including connections etc. as required. 6 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. 7 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. (2 Nos. of switch and sockets are reqired for each cable TV points.) 8 Supplying and fixing of TV antenna socket outletpiano typeon the existing switch box/ cover including connections etc. as required. 9 Supplying and drawing of co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required. 10 Supplying and fixing of 25 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required(25m taken for each TV Cable and 25 m for all plug points). 11 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 12 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 13 Supplying and drawing of 1x1.5 sqmm of FRLS PVC insulated copper conductor, single core (multi stranded) cable .for Inverter in the existing surface/ recessed steel/ PVC conduit as required. 14 Supplying and fixing of 8way (4+24), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board (TPN DB) , 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 15 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of Single polein the existing MCB DB complete with connections, testing and commissioning etc. as required. 16 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core (multi stranded) cable in surface/ recessed medium class PVC conduit as required.2X 2.5sq.mm+1X2.5sq. mm earth wire 17 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core (multi stranded) cable in surface/ recessed medium class PVC conduit as required. 2X 4sq.mm+1X4sq. mm earth wire 18 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core (multi stranded) cable in surface/ recessed medium class PVC conduit as required.2X 6sq.mm+1X6sq. mm earth wire 19 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core (multi stranded) cable in surface/ recessed medium class PVC conduit as required.4X 10sq. mm + 2X 6 sq. mm earth wire 20 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 21 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 22 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 23 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 24 Supplying, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor notless than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 25 Supply and fixing 100 A FP MCB 240V/415 V, 10 kA, C curve, miniature circuit breaker complete in all respect. 26 Supply and Fixing LED Bulb 9 watt lumen 810 to 945 complete in all respect 27 Supply & fixing of water tight oblong 10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08, High purity / transmisivity UV Stabilized Non yellowish diffuser/ for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24 Hr Continuous Operation,1200 system lumens, >120 Lm/W, PF>0.95, CRI >70, >300V over voltage protection, 4 KV internal Surge Protection, metal housingwith 5 years warrantee Complete in All respect. compelete in all respect. 28 Supply and fixing of single light wall bracket with opal glasspaint finishing up to 6 watt LED complete in all respect. 29 Supply and fixing of 18-22W LED Batten fitting 2160-2640 system lumens, >120 Lm/W, PF>0.95, THD<10%,CRI >80, >300V over voltage protection, 2.5 KV internal SurgeProtection, with 5year warrantee with Extruded Aluminum housing, special polycarbonate diffuser for glare free light distribution and suitable mounting for on both surface & suspended Compelete in all respect. 30 Supply and fixing Lamp basedLED Mirror Light 11 watt lumen 800 complete in all respect. 31 Supply and fixing of LED Street light Fitting with mandatory driver set, having die cast aluminium body with toughend glass/ UV stabilized PC Cover and lenses suitable for 45 Watt. to 50 Watt, Confirming to IP 66, and IK07 and above protection having Company LOGO Engraved 5400-6000 system lumens, High Power LED with lenses, 120 Lm/W, PF>0.95, THD <10% at full load, CRI >70, Potted driver Set in Metal housing (NotCircuitory), Phase to Phase protection at 440V, >300V over voltage auto cut and restart feature, 4 KV internal Surge Protection, with 5 years warrantee complete in all respect. 32 Supply of fresh airFan 300mm 1-phase 1400 rpm,230/250 volts,50Hz. 33 Dismantaling of olid Electrical Installation and less cost of old material and repairing of surface