| 1 | Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed(Ref. Page no-1, Item No2(a) of PWD Sch. of Rates 2017). |
| 2 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (Ref. Page no-1, Item No2(a) of PWD Sch. of Rates 2017). |
| 3 | Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor(i) (1:3:6 proportion)(Ref. Page no-34,Item No-22 of PWD Sch. of Rates 2017). |
| 4 | Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth(Ref. Page no-15,Item No-8 of PWD Sch. of Rates 2017). |
| 5 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. (Ref. Page no-16,Item No-16 ,of PWD Sch. of Rates 2017). |
| 6 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)(Ref. Page no-2,Item No-4 ofPWD Sch. of Rates 2017). |
| 7 | 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound asper manufacturer\"s specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer basedpaint to be paid separa(Ref. Page no-47,Item No-1of PWD Sch. of Rates 2017). |
| 8 | Hire and labour charges for shuttering with centering andnecessary staging upto 4 m. using approved stout props andthick hard wood planks of approved thickness with requiredbracing for concrete slabs, beams, columns, lintels curved orstraight including fitting, fixing and striking out after completionof works (upto roof of ground floor)a) 25 mm to 30 mm thick wooden shuttering as per decision &direction of Engineer-In-Charge without staging in foundation(Ref. Page no-42,Item No-36 of PWD Sch. of Rates 2017). |
| 9 | Reinforcement for reinforced concrete work in all sorts ofstructures including distribution bars, stirrups, binders etc. initialstraightening and removal of loose rust (if necessary), cutting torequisite length, hooking and bending to correct shape, placingin proper position and binding with 16 gauge black annealedwire at every intersection, complete as per drawing anddirection.(Ref. Page no-43,Item No-40,(a),of PWD Sch. of Rates 2017). |
| 10 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortarincluding rounding off or chamfering corners as directed andraking out joints or roughening of concrete surface includingthroating, nosing and drip course where necessary (ground floor).With 6:1 cement mortar Inside.(Ref. Page no-189,Item No-1 of PWD Sch. of Rates 2017).(b)15 mm thick plaster(1:6) |
| 11 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mmnominal size) excluding shuttering and reinforcement if any, in ground flooras per relevant IS codes.(Ref. Page no-26Item No-10 of PWD Sch. of Rates 2017). |
| 12 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement In ground floor. (as necessary) and marble 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). (iii) 35 mm. thick (Ref. Page no-48,Item No-6) ,of PWD Sch. of Rates 2017) |
| 13 | Neat cement punning about 1.5 mm. thick in wall, dado,window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.(Ref. Page no-192,Item No-15,of PWD Sch. of Rates 2014). |
| 14 | Applying Interior grade Acrylic Primer of approved quality and brandon plastered or cencrete surface old or new surface to receiveDistemper/ Acrylic emulsion paint including scraping and preparingthe surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)PWD(WB), S.O.R. Volume - I : Item No.-7, Page No. - 195 |
| 15 | Applying Acrylic Emulsion Paint of approved make and brand on wallsand ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) (Two coats) PWD(WB), S.O.R. Volume - I : Item No.-4, Page No. - 201 |
| 16 | Applying Exterior grade Acrylic primer of approved quality and brandon plastered or cencrete surface old or new surface to receivedecorative textured (matt finish) or smooth finish acrylic exterioremulsion paint including scraping and preparing the surface throughly,complete as per manufacturer\"s specification and as per direction of the EIC(b) Two Coats page 196 item 8 |
| 17 | Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer\"s specification and as per direction ofEngineer-in-Charge to be applied over acrylic primer as required. Therate includes cost of material, labour, scaffolding and all incidentalcharges but excluding the cost of primer.PWD(WB), S.O.R. Volume - I : Building Works w.e.f. 01/11/2017, Item No.-17, Page No. - 197 |
| 18 | a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.Item No.-1, Page No. - 200 |
| 19 | (A) Painting with best quality synthetic enamel paint of approved makeand brand including smoothening surface by sand papering etc. includingusing of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :(ii) Two coats (white in shade)Item No.-2, Page No. - 200 |
| 20 | M.S. structural works with hollow sections (square or rectangularshape) conforming to IS: 806-1968 & IS:1161-1998) connected toone another with bracket, gusset, cleat as per design, drawing &direction of Engineer-in-Charge complete including cutting torequisite shape & size, fabrication including metal arc weldingconforming to IS: 816-1969 & IS: 9595 using electrodes of approvedmake and brand conforming to IS:814- 2004, haulage, hoisting anderection all complete.The rate includes the cost of all M.S. Hollow section, allconsumables such as electrodes, gas and hire charges of all toolsand plants and labour reqired for execution and all incidentalchages (such as electricity, labour insurance) etc. complete. (Ref. Page no-101,Item No-2A ,of PWD Sch. of Rates 2017). |
| 21 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(Ref.page no 83 item no.15of PWD Sch. of Rates 2017). |
| 22 | Aluminium sheet ridging fitted with self tapping screws,EPDM washers etc complete.(Minimum 225mm end lapping).(A) 300 mm lapping each (a) With 0.71 mm sheet(Ref.page no 84item no.18of PWD Sch. of Rates 2017). |
| 23 | Ceiling with 12mm thick wooden planks fitted and fixed complete (excluding the supporting framework) as per direction of the Engineer-in-charge. In Ground Fl(a) Ordinary TeakPage162 Item-7 |
| 24 | Supplying bubble free float glass of approved make and brandconforming to IS: 2835-1987(Ref.page no 243 item no.9of PWD Sch. of Rates 2017). |
| 25 | Supplying, fitting and fixing clear visioned, Insulated Double Glazed two tracksliding Aluminium window (U-value < 3.2W/m 2 K) made up with 6 mm thicktoughened glass (wt > 15kg/m 2) with 12 mm air gap in between, containingperforated Al/ structural foam spacer filled with moisture absorbant dessicant atall sides duly sealed with primary sealant (polyisobutylene) and affixed insidemulti cellular/ multi chember profiles of required section made of Alluminiumalloy extrusions conforming to IS:733-1983 and IS:1285 - 2002annodised/powder coated with (required film thickness and specified colour/natural) matt finished conforming to IS: 1868-2006/ IS: 13871-2002 measuredas per IS:6012-1992, and sealed appropriately with secondary(polysulphide/silicon) sealant all junctions complete in all respect as perdirection and satisfaction of Engineer-in-Charge including all incidentalcharges. (Payment shall be made on finished size of Aluminium windowincluding frame.)(Ref.page no 243 item no.9of PWD Sch. of Rates 2017) |
| 26 | (a) M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in groundfloor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25%for each addl. floor above 4th floor)(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. (Ref.page no 104 item no.13of PWD Sch. of Rates 2017) |
| 27 | Add 18 % GST |
| 28 | Add 1 % Cess |