Construction Of Components Of Waste To Compost (W2c) And Material Recovery Facility (Mrf) Plant Under Swachh Bharat Mission (Sbm-U 2.0) With 15Th Fc Tied Grant-Compost Pit - Sapatgram M.B 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil230 mm thick wall115 mm thick wallPlinth Proctection wallpole Pit 3 Dry brick pitching half brick thick in drains including supply of bricks andpreparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 4 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from naturalsources : 6 graded stone aggregate 20 mm nominal sizederived from natural sources) 5 Brick work with common burnt clay modular bricks of class designation7.5 in foundation and plinth in:Cement Mortar 1:4 (1 cement : 4 coarse sand). 6 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) 7 Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 8 15 mm cement plaster on the rough side of single or half brick wall ofmix :1:6 (1 cement: 6 fine sand) 9 White washing with lime to give an even shadeNew work (three or more coats 10 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes 11 Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 12 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to anypitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I. plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.2 mm thick corrugated (2.5 or 4.2 or 6) or step-down (2 or 3 or 6 ) as specified 13 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed withpolymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumenwashers complete.0.80 mm thick with zinc coating not less than 275 gm/m² 14 Providing and fixing bolts including nuts and washers complete 15 ELECTRONICS EQUIPMENTS REQUIRED ATSITE 16 Supply and installation of 1000kg and 100g Accuracy Heavy Duty Steel Platform Digital Weighing Scaleincluding all equpment , materials , complete with all taxes. 17 Computer with in-built modem & fax software 18 Printer 19 Telephone (land line) 20 Wireless/ Mobile phone 21 Complaint log book 22 Table 23 Chairs 24 INTERNAL ELECTRIFICATION IN ALL BUILDINGS 25 PVCsinglecoresheathedcableWiring withcopperconductorcablesInstove enamelledStee l Conduit .One light point or one fan point controlled by one switch with cables 1.5 sq. mm size Group A 26 PVCsinglecoresheathedcableWiring withcopperconductorcablesInstove enamelledStee l Conduit .One light point or one fan point controlled by one switch with cables 1.5 sq. mm size Group C 27 Wiring for light point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 2.5 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 28 Wiring for light/ power plug with 4 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 29 Supplying and fixing of following sizes of PVCconduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 30 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75x75x50mm 31 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 147x93x47mm 32 supply and fixing following modular base & cover plate on existing modular metal boxes etc as required. 4/5 module 33 Supply and fixing following modular switch andsocket on the existing modular plate & switchbox including connections but excludingmodular plate etc as required 3 pin 5/6 amp socket outlet 34 Supply and fixing following modular switch andsocket on the existing modular plate & switchbox including connections but excludingmodular plate etc as required Telephone socket outlet 35 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc asrequired 36 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etcas required 37 supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required 38 Supply and fixing call bell/ buzzer suitable for D.C/ A.C single phase 230 volts complete as required. 39 Supply and fixing 3 pin, 5 amp. Ceiling rose on the existing junction box/ wooden block including connection etc as required. 40 Supply and fixing brass batten/ angle holder including including connection etc as required 41 Installation, testing and comissioning of ceiling fan, ancluding wiring the down rods of standard length(upto 30 cm) with 1.5sq mm FR PVC insulated, copper conductor single core cable, including providing and fixing phenolic laminated sheet cover on fan box etc as required 42 Installation , testing and commissioning of pre wired,flourescent fitting/compact flourescentfitting of all types, comlete with all accessories and tube etc directly on ceiling/wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required. 43 Installation , testing and commissioning of prewired, flourescent fitting/compact flouredcent fitting of all types, comlete with all accessories and tube etc. including supplying and fixing ball and socket arrangement 2no down rods of 20mm dia X 1.6mm thick steel conduit upto 30cm lenth painting and wiring the down rods and connection with 1.5 sq mm FR PVC insulated, copper conductor, single core cable and earthing etc as required. 44 Installation of exhaust fan upto 510 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc as required. 45 Extra for cutting and threading of G.I pipe heavy guage down rod for ceiling fan etc. as required 46 Supply and fixing following way, single poleand neutral, sheet steel, MCB distributionboard, 240 volts, on surface/ recess, completewith tinned copper busbar, neutral busbar,earth bar, din bar, detachable gland plate,interconnections, phosphatized and powderpainted including earthing etc as required. 2way single door 47 Supply and fixing 6 amps to 32 amps rating 240 volts B series miniature circuit breaker suitable for lighting and other loads of following poles in the exsisting MCB DB complete with connection testing and commisssioning etc. as required 6/32 amps, single pole B series 48 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required 49 Separation room/chamber (10.00m X 3.00m) 50 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 51 Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm Back Face, Side & Partition , Front Face 52 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.ISA-40x40x5 - Vertical bar , ISA-25x25x2- Tie bar, MS flat bar 40x5,Front open lid 53 GI sheet 0.8 mm thick confirming to IS 277:1992 at bottom 54 Mild steel plates 2mm thick for front open lid 55 Welding by gas or electric plant including transportation of plant at site etc. complete.For gate opening, Front & back face,Sides and partitions 56 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete 50x37x1.50 mm 57 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :100x10 mm 58 Conveyor Belt 59 Sypply and installation of Conveyor Belt of required capacity including all acesseries complete as per direction of Engineer-in-Charge 60 Recyclable Storage & Compost Storage 1 Nos 27.425 x 6.54 m 61 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, asdirected by Engineer-in- Charge:All kind of soil, In Ordinary Soil, 230 mm thich wall ,Column 62 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources) 230 mm thich wall, Column 63 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal sizederived from natural sources) For Foundation pillars,Foundation,Upto Plinth Beam,Plinth Beam 64 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level,1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) Above Plinth Beam,Lintel Beam,Roof Beam,Sunshed,Slab 65 Steel reinforcement for R.C.C. work including straightening, cutting bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more 66 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate Waste Receiving, Segragation & Cutting Chopping 67 Supplying & fixing Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. (Fe 410 -W Gde-E-250) quality -A Angle iron of 50 x 50 x 6 (as per IS:226) ISMC Channel size ISMC 100 (as per IS: 227) 68 Supplying & fixing Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment. (Fe 410-W Gde-E-250) quality-A MS Plate 12 mm thick 69 M & L Add to any of the foregoing items if structural steel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractors workshop before fabrication. 70 Supplying & fixing Plain, galvanished, mild steel sheeting, in ridges, hips, valley gutters, drip and straits flashing (length and girth as fixed) with grade of zinc coating 275. Thickness in (0.08mm) Ridges, Gutter 71 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (75 mm) 72 Supplied and fixed stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof. (Bore of pipe in 100mm) 73 Balling Machine 74 Sypply and installation of Balling machine of required capacity including all acesseries complete as per direction of Engineer-in-Charge 75 Trommel 76 Supply and installation of Trommel of required capacity including all accessories complete as per directionof Engineer-in-Charge 77 Shredder 78 Supply and installation of Shredder of required capacity including all accessories complete as per directionof Engineer-in-Charge 79 Construction of Shed for MRF Centre 80 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil230 mm thick wall115 mm thick wallPlinth Proctection wallpole Pit 81 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 82 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 83 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 84 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 85 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) 86 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more 87 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) 88 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 89 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 90 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 91 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/ m² 92 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m² 93 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (60.3mm OD hollow pipe) 94 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes (SHS-40 X 40 X 2.6 mm) 95 Boring 96 Cost if Transportation and other miscellaneous charges for setting the Rig Machine at site all complete job as per direction of E/I 97 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.300 mm dia 98 Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticized PVC medium well casing (CM) pipe of requireddia, conforming to IS: 12818, including required hire and labourcharges, fittings & accessories etc. all complete, for all depths, asper direction of Engineer -in-charge 100 mm 99 Providing and fixing GI or CI cap for 200 mm NB dia UPVC pipe 100 Supplying installing in to the 200 mm / 165 mm nominal dia bore well & commissioning of 100 mm dia submersible motor pump set pump capable to discharge 0.70 LPS against a total head up to 70 mtrs of Kirlosker/ Jyoti/KSB make as per IS 1520/1980 coupled with 220V, single phase, 50Hz AC and wet type winded submersible motor, including cost of 32 mm dia GM full way wheel valve 32mm dia NR valve heavy type MS clamps-2 Nos etc as per requirement, all complete as per direction of E/I 101 Cost of 32 mm dia UPVC (schedule 80) of approved make including lowering of pipe in the bore and transportation to work site etc. as per specification and director of E/I 102 Supplying installing and commissioning of panel board suitable for motor pump set as mentioned in the item No.-5, having Voltmeter, ammeter, phase indicating lamps, starters, main switch fuses inter connection in the panel board including cost of wires etc all complete job as per specification and direction of E/I 103 Cost of PVC insulated copper submersible cable (2.5 sq mm x 3 core) of finolex or equivalent make including lowering and making water proof joints including all taxes and transportation to work site etc as per specification and direction E/I. 104 Supplying and commissioning of 5 KVA servo stabilizer of sen & Pandit or pagaria or approved equivalent make (Range 90 V-300 V) single phase with cable, change over switch for submersible pump etc all complete as per specification and direction of E/I 105 Supplying and commissioning and fitting pre enamalated 3 core 6 sqmm aluminum service wire from pole to the panel board including cost of wires etc and stretching charges all complete job. 106 Earthing with copper earth plate 600 mm x 600 mm x 3mm thick including accessories and providing masonry enclosure with cover plate having loaking arrangement and watering pipe etc as required salt charcol for GI of copper plate earth electrode as required 107 Supplying, fitting & commissioning of automatic electronic sensor device to stop the motor at the time of over flow of water from over head tank etc and when the water level in bore well goes down the specified depth. 108 Providing 32 mm dia GI elbow confirming IS specification including cost of all material labour jointing material all complete job, 109 Supply and fixing GI Reducing teeplain 32 mm dia 110 Toilet Block 111 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, asdirected by Engineer-in- Charge:All kind of soil,In Ordinary Soil,For walls,step 112 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm/ (Soft/ loose soil) 113 Material & Labour Sand filling under floors or in foundations including watering and consolidation Below lean concrete,Below flooring,In Bath room,In W.C.,In Lobby Area 7.98 Sq M,In Steps 114 Soling (or sub base) of well burnt soling bricks including filling of interstices and rolling. (Old size bricks, one layer laid on flat)Below wall foundation,In steps foundation 115 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources) In lean concrete,Below Flooring,In Bath Room,In W.C.,In Urinal,In Lobby,In Steps 116 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:In proportion 1:4,In walls,In Steps 117 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived fromnatural sources 118 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand),In walls, In parapet wall in C.M. (1:6) 119 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) In lintel Beam at entrance,In lintel Beam for window opening ,For Door ,In Ventilation 120 Reinforced cement concrete (nominal mix) in : Chhajja Type B1 (1:2:4 20 mm graded aggregate),Sun shade at entrance 121 Reinforced cement concrete (nominal mix) in : Slabs supported on wall, beams and column in floors, roofs, landings balconies, canopies, deck slabs and in shelved and the like. Type B1 (1:1.5:3) 20 mm graded aggregate) In Roof Slab area 15.61 Sqm 122 Supplying fitting and fixing in position reinforcement bars confirming to relevant IS code for RCC work/ RB work, walling including straighting cleaning, cutting and bending with 20 G annealed black wire and placing in position with proper blocks supports, chair, spacers etc. complete (i) TMT Corrosion resistant steel (CRS) reinforcement bars 123 12 mm thick cement Plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finshed even and smooth including curing complete as directed.In Walls outerface,In Parapet Walls,In Walls innerface,In Steps,In Toilet,In Lobby,In Urinal 124 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :In Steps,In Lobby 125 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.In Toilet,In Urinal 126 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.With commercial grade colour 15x15 cms tiles ,In Urinal 127 White washing with lime to give an even shade : New work (three or more coats) Inner Walls,Qty same as plaster in ceiling. White washing three coats over new surfaces in ceiling. 1st coat Undecorated surface. 128 Making plinth protection 50mm thick of cement concrete 1:3:6 2 cement: 3 coarse sand: 6 graded stone aggregate 20 mm normal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 129 SProviding and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter 130 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter. 131 Butt hinges, heavy weight, cold rolled mild steel, and fixed (size of hinges in 100mm) 132 Supply and fixing Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides if both faces is covered with decorative face veneer with lipping/ frame to match 30mm. 133 Supplied and fixed steel door, windows or ventilators, fixed type, with glazing bars. 134 Providing and fixing M.S. fan clamp type I or II of 16mm dia M.S. Bar, bent to shape with hooking ends in R.C.C.. slabs or beams during laying, including, painting the exposed portion of loop, all as per standard design complete. 135 Plain, solid, straight chow Kats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed (1st class hardwood) Door Frame 136 Supplying, fitting and fixing collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete At Entrance Gate 137 Providing precast cement concrete louvers and jallies, 25mm thick (measured solid), including all mouldings but excluding frame (Pre cast frame shall be measured separately and paid for under item 04032) type B- O 1: 2:4 (12.5mm graded aggregate) set in cement mortar 1:4 138 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work 139 Material and labour French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats 140 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: a) after surface preparation, first layer of slurry of cement @0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. 141 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : (W.C. pan with ISI marked white solid plastic eat and lid) 142 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever require : (Single half stall urinal with 5 litre P.V.C. automatic flushing cistern) 143 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 144 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 145 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including cost of cutting holes and making good the 100 mm dia Pipe 146 Providing and fixing G.I. pipes complete with G.I. fittings and clams, including cutting and making good the walls etc. (Internal work): concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 15 mm dia piles 147 Providing and fixing G.I. pipes complete with G.I. fittings and clams, including cutting and making good the walls etc. (Internal work): concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 20 mm dia piles 148 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 30 mm nominal bore50mm dia 149 Fixing only water meter, metal stopcock gunmetal gate valve, brass ball valve, gunmetal non-returning valve in PP-R pipe line (cost of male sockets included). (Bore of pipes in 20) mm 15mm dia 150 Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I. Capacity in 1000 liters. 151 Providing and fixing brass bib cock of approved quality : 15 mm nominal bore 152 Providing and fixing C.P. brass bib cock of approved quality conforming to IS : 8932.15mm nominal bore 153 Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102mm, height of 75mm with concealed fitting arrangement. Weighing not less than 106 gms. 154 Septic Tank with soak pit 155 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, asdirected by Engineer-in- Charge:All kind of soil,Septic Tank,Inlet Chamber,Soakpit tank,Out let Chamber,150 mm dia Inlet / Out Let Pipe 156 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources) In Prop 1 cement: 4 sand: 8 coarse aggregate by volume,Septic Tank,Inlet Chamber,150 mm dia Inlet / Out Let Pipe 157 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal sizederived from natural sources),Vertical and horizontal fins,M15 Grade concrete prop 1:2:4,Septic Tank,Inlet Chamber 158 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:In proportion 1:4,Inlet Chamber,Septic Tank,Buffle Wall,Out let Chamber,Soakpit tank 159 Providing and laying plane/ reinforced cement concrete works cement, coarse sand & 20 mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately),Slab (M-20 grade concrete prop 1:1.5:3),Slab,Inlet Chamber,Soakpit tank 160 Steel reinforcement for R.C.C. work including straightening, cutting bending, placing in position and binding all complete above plinth level,Thermo-Mechanically Treated bars of grade Fe-500D or more 161 Reinforced concrete pipes, class NP2, laid and jointed complete with collars,150 mm dia R.C.C. Pipe Class NP - 2 162 12 mm thick cement Plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finshed even and smooth including curing complete as directed.On fair side ,In cement mortar 1:4,Inlet Chamber,Septic Tank,Buffle Wall,Out let Chamber 163 Office Room (3 x 3 M) 164 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, asdirected by Engineer-in- Charge:All kind of soil,In Ordinary Soil 165 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm/ (Soft/ loose soil) 166 Material & Labour Sand filling under floors or in foundations including watering and consolidation Below flooring,In steps 167 Soling (or sub base) of well burnt soling bricks including filling of interstices and rolling. (Old size bricks, one layer laid on flat),Below wall foundation,In steps foundation 168 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources),In lean concrete,In flooring,In steps 169 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:In proportion 1:4,In walls,In Steps 170 Damp proof course to horizontal or vertical surfaces including necessary formwork. In cement concrete 1:2:4, type B-0 171 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand),In walls,In parapet wall in C.M. (1:6) 172 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources),In lintel Beam for door opening,In lintel Beam for window opening 173 Reinforced cement concrete (nominal mix) in : Chhajja Type B1 (1:2:4 20 mm graded aggregate) 174 Providing precast cement concrete solid building blocks or slab 10cm thick (with plain or interlocking joints as directed) setting in mortar, complete in walls. Type B1-1:2:4 (20mm graded aggregate) set in cement mortar 1:4. 175 Reinforced cement concrete (nominal mix) in : Slabs supported on wall, beams and column in floors, roofs, landings balconies, canopies, deck slabs and in shelved and the like. Type B1 (1:1.5:3) 20 mm graded aggregate) 176 Steel reinforcement for R.C.C. work including straightening, cutting bending, placing in position and binding all complete above plinth level 177 12 mm thick cement Plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finshed even and smooth including curing complete as directed.In walls,in Steps 178 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 179 Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick 180 White washing with lime to give an even shade : New work (three or more coats) Inner Walls 181 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cemnt: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 182 SProviding and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 75 mm diameter 183 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter 184 Butt hinges, heavy weight, cold rolled mild steel, and fixed (size of hinges in 100mm) 185 Supply and fixing Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides if both faces is covered with decorative face veneer with lipping/ frame to match 30mm. 186 Supplied and fixed steel door, windows or ventilators, fixed type, with glazing bars. 187 Providing and fixing M.S. fan clamp type I or II of 16 mmdia M.S. bar, bent to shape with hooked ends in R.C.C. slabsor beamsduringlaying,including paintingtheexposedportionofloop,all as per standarddesign complete 188 Plain, solid, straight chow Kats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed (1st class hardwood) Door Frame 189 Surfaces of any description, not otherwise described, over 10cm width or girth Synthetic enamel (ordinary tint) (each coat) For Door & Window Frame 190 Material and labour French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats 191 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.