| 1 | [10.106]Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 0 0 0 [Through Rate] |
| 2 | [10.14]Providing a floating coat of 1.50 mm thick neat cement laid in one operation to the topping. [Through Rate] |
| 3 | [10.22.1]Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. 1. 40 mm wide and 4 mm thick [Through Rate] |
| 4 | [10.4]Providing and laying of screedof50mmthickcementconcrete 1:8:16 to be laid below the topping. [Through Rate] |
| 5 | [10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate] |
| 6 | [10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thickin skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade ofGranite including labour for fixing cramps pins and dowels etc. [Through Rate] |
| 7 | [10.52.1]Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. [Through Rate] |
| 8 | [10.53.1]Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. [Through Rate] |
| 9 | [10.55]providing and fixing 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick levelling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete. [Through Rate] |
| 10 | [10.61]Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding pointing the joints with white cement and matching pigments etc., complete. [Through Rate] |
| 11 | [10.62]Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. [Through Rate] |
| 12 | [10.63.3]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. 3. Size of Tile 800x800 mm [Through Rate] |
| 13 | [10.67.3]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 3. Size of Tile 800x800 mm [Through Rate] |
| 14 | [10.7]Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4 [Through Rate] |
| 15 | [10.70.3]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 3. Size of Tile 800x800 mm [Through Rate] |
| 16 | [11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge [Through Rate] |
| 17 | [11.58]Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete [Through Rate] |
| 18 | [11.61.1]White washing with lime to give an even shade : 1. New work (three or more coats) [Through Rate] |
| 19 | [11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer [Through Rate] |
| 20 | [11.73.1]Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer`s specifications including appropriate priming coat, preparation of surface, etc. complete. 1. On steel work [Through Rate] |
| 21 | [11.82.1]Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work [Through Rate] |
| 22 | [11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate] |
| 23 | [12.12.2]Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 2. 1.0 mm thick [Through Rate] |
| 24 | [12.130.3]Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact and UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS-1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete 3. Double glass glazing comprising of 6 mm thick toughened clear glass + 12mm air gap + 5mm annealed clear glass. [Through Rate] |
| 25 | [12.136.4]Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with1.60 ± 0.2 mm thickgalvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile),appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with keyon one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) crescent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware`s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 4. Three track three panels sliding door with fly proof S.S wire mesh (Two Nos. glazed & one no. wire mesh panels) made of (big series)frame 116 x 45 mm & sash 46 x 82 mmboth having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm up to 5.00 sqm) [Through Rate] |
| 26 | [12.140]Providing and fixing steel roller for uPVC sliding window with necessary screws etc. complete. [Through Rate] |
| 27 | [12.142]Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete. [Through Rate] |
| 28 | [12.171]Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). [Through Rate] |
| 29 | [12.36.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate] |
| 30 | [12.80]Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. [Through Rate] |
| 31 | [13.20]Providing and Fixing Poly Carbonate Sheet 1.25mm thickness on Gates and grills excluding the cost of MS framework but including the cost of nut bolts, Welding rods complete in all respect as per direction of Engineerin-Charge. [Through Rate] |
| 32 | [13.21.1]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 1. Door Frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter [Through Rate] |
| 33 | [13.28]Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. [Through Rate] |
| 34 | [13.30.1]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 1. Hot finished welded type tubes [Through Rate] |
| 35 | [13.37.1]Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 1. 80x1.25 mm M.S. laths with 1.25 mm thick top cover [Through Rate] |
| 36 | [13.38]Providing and fixing ball bearing for rolling shutters. [Through Rate] |
| 37 | [13.39.1]Extra for providing mechanical device chain and crank operation for operating rolling shutters. 1. Exceeding 10.00 sqm and up to 16.80 sqm in the area [Through Rate] |
| 38 | [13.4.1]Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 39 | [13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate] |
| 40 | [13.6.1]Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 1. Using M.S. angels 40x40x6 mm for diagonal braces [Through Rate] |
| 41 | [13.9.2]Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3 mm and nuts and bolts complete. 2. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides [Through Rate] |
| 42 | [17.14.1]Granular Sub-Base with Close Graded Material - (Table:- 400-1) Plant mix methodConstruction of granular sub-base by providing Material as per Grading III (Table 400-I of MORTandH 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORTandH specifications 1. Grading I material [Through Rate] |
| 43 | [17.14.2]Granular Sub-Base with Close Graded Material - (Table:- 400-1) Plant mix methodConstruction of granular sub-base by providing Material as per Grading III (Table 400-I of MORTandH 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORTandH specifications 2. Grading II material [Through Rate] |
| 44 | [17.5.3]Compacting Original Ground 3. Compaction of EarthworkCompaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications [Through Rate] |
| 45 | [17.69.2]Interlocking Concrete Block Pavement 2. Providing and Laying 80 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. [Through Rate] |
| 46 | [17.72]Constructionofunreinforcedplaincementconcrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawingsandtechnicalclause1501ofMORTH specifications [Through Rate] |
| 47 | [18.25]Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides, made from rigid foam sheets (Single extruded) having density 600 kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardantwith necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastener with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. [Through Rate] |
| 48 | [18.26]Providing and fixing factory madeKitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardanthaving necessary screw holding capacity.Shutter shall be fixed to frame usingapproved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. [Through Rate] |
| 49 | [20.114.3]Supplying erection, testing of fullyautomatic electric control panel board forT/Wells in Pump Chamber consisting ofMS sheet of thickness 14 gauge dulypainted box type floor mounted made ofangle Frame containing 1 no. fullyautomatic air brake starter suitable forMotor of the following capacity, Minswitch of suitable range with HRC fuse, 1no. volt meter (0 to 500 volts), 1 No.Amp. Meter of 0 to 100 amp. 3 sets ofindicating lamp capacitor of suitablecapacity and 1 no. single phase preventerswith the timer switch including wiring inpanel board and suitable electric energymeter wiring in Electric Control PanelBoard complete in all respect as perspecification given in Schedule No. II,Including MCB, suitable, Capacitor,Wooden Box etc as per siterequirement complete in all respect. 3. 20 HP Motor [Through Rate] |
| 50 | [20.52.5]providing and placing in horizontal layers filtering media screened washed and cleaned as described below - 5. Bottom layer Broken stone, screened, washed and graded from 50 mm to 75 mm (from Ghaggar or approved equivalent quarry) [Through Rate] |
| 51 | [20.71.1]Supply, erection, testing of Ceiling fansIS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\" (1200mm) [Through Rate] |
| 52 | [20.72]Supplying, errection, testing of Exhaustfan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structureconfirming to latest IS specificationscomplete in all respect to satisfaction of Engineer-in-charge. [Through Rate] |
| 53 | [20.84]Providing and fixing of insulated rubber matting suitable for 11 KV installation 1 M x 2 M x 12 mm thick (IS code 15652-40091)as per specification complete and as per directions of Engineer-in-charge [Through Rate] |
| 54 | [20.85.2]Supplying and Fixing of PVC water bars for water stops flexible physical plastic for preventing leakage in concrete joints to avoid seepage ( Fixo- stop) with ribs and central bulbs marked as per IS-12200 of 2001 along with bitumen filler complete in all respects. 2. 150mm wide X 6.00 mm thickness of wall [Through Rate] |
| 55 | [20.86]Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects. [Through Rate] |
| 56 | [21.110.14]Supplying, erection, testing andcommissioning of submersible motorpumping set non clog for seweragehaving head 30.00 m as per the indicatedrequirements of discharge in LPM andpower capacity in BHP as per IS markedincluding all accessories (like SS Pipes,SS Chain (Shackle Chain) ,SS FoundationBolt, complete base frame, Monorail,Chain Guide Line, Auto Compiling, DuctFoot Bend (D/F Bend) etc. complete in allrespect 14. Discharge Capacity (LPM) - 700Power Capacity (BHP) - 7.5 [Through Rate] |
| 57 | [21.28]Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge [Through Rate] |
| 58 | [21.43]Extra over the rate laid down in this schedule for cement concrete work more making and finishing benching and complicated floor work in manholes, including formation of channels and bulldozing and smooth finishing the surface accurately to template. [Through Rate] |
| 59 | [21.84.1]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 1. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping [Through Rate] |
| 60 | [21.84.2]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 2. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) [Through Rate] |
| 61 | [21.84.3]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) [Through Rate] |
| 62 | [21.85.1]Extra for every 0.30 metre depth of Inspection chamber 1. 450 mm x 450 mm inside [Through Rate] |
| 63 | [21.85.2]Extra for every 0.30 metre depth of Inspection chamber 2. 450 mmx 600 mm inside [Through Rate] |
| 64 | [21.85.3]Extra for every 0.30 metre depth of Inspection chamber 3. 600 mm x 900 mm inside [Through Rate] |
| 65 | [22.10.2.2]Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 2.2. Kitchen sink without drain board610x460 mm bowl depth 200 mm [Through Rate] |
| 66 | [22.101.2.1]Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore [Through Rate] |
| 67 | [22.103.2]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 2. 20 mm nominal bore [Through Rate] |
| 68 | [22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore [Through Rate] |
| 69 | [22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate] |
| 70 | [22.106.1]Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore [Through Rate] |
| 71 | [22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate] |
| 72 | [22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. [Through Rate] |
| 73 | [22.110.1]Providing and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 1. 15 mm nominal bore [Through Rate] |
| 74 | [22.119.2]Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. [Through Rate] |
| 75 | [22.14.2.1]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 2.1. Flexible pipe 32 mm dia [Through Rate] |
| 76 | [22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. [Through Rate] |
| 77 | [22.166.1.1]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P type With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 78 | [22.19]Providing and fixing 100 mm sand cast Iron grating for gully trap. [Through Rate] |
| 79 | [22.192.1.1]Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.1. 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 80 | [22.194.1.1]Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.1. 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 81 | [22.195.1]Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : 1. With common burnt clay non-modular bricks of class designation 7.5 [Through Rate] |
| 82 | [22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate] |
| 83 | [22.211]Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. [Through Rate] |
| 84 | [22.216.3]Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-in-charge. 3. 35 Litres capacity [Through Rate] |
| 85 | [22.221.11]Providing and fixingin position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 11. Table Top (size 49 x 40 x 15 cm) [Through Rate] |
| 86 | [22.221.9]Providing and fixingin position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 9. Size 560mm x 450mm (Under counter oval) [Through Rate] |
| 87 | [22.222.2.1]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 88 | [22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate] |
| 89 | [22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. [Through Rate] |
| 90 | [22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. [Through Rate] |
| 91 | [22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass [Through Rate] |
| 92 | [22.46]Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water (250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. [Through Rate] |
| 93 | [22.50.1.1.2]Providing and fixingpartitions for different type of urinals. 1.1.2. Vitreous Chinaware Partition plate. Small size 680mm x 330 mmSingle Colour [Through Rate] |
| 94 | [22.85.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate] |
| 95 | [22.85.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate] |
| 96 | [22.85.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 5. 40 mm nominal outer dia Pipes [Through Rate] |
| 97 | [22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate] |
| 98 | [22.87.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 6. 50 mm nominal outer dia Pipes [Through Rate] |
| 99 | [22.87.8]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 8. 75 mm nominal inner dia Pipes [Through Rate] |
| 100 | [22.87.9]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.External work 9. 100 mm nominal inner dia Pipes [Through Rate] |
| 101 | [22.98.3]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. [Through Rate] |
| 102 | [22.98.4]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore [Through Rate] |
| 103 | [22.98.7]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 7. 80 mm nominal bore [Through Rate] |
| 104 | [22.99.4.2]Providing and fixing gun metal non- return valve of approved quality (screwed end) : 4.2. 50 mm nominal bore Vertical [Through Rate] |
| 105 | [23.1.6.2]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.2. Wiring main ,sub mains and Circuit wiring in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate] |
| 106 | [23.1.6.3]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.3. Wiring main ,sub mains and Circuit wiring in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate] |
| 107 | [23.1.6.4]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.4. Wiring main ,sub mains and Circuit wiring in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate] |
| 108 | [23.1.6.5]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.5. Wiring main ,sub mains and Circuit wiring in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate] |
| 109 | [23.2.1.2]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etcin 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B [Through Rate] |
| 110 | [23.2.2.2]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 2.2. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face platein 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B [Through Rate] |
| 111 | [23.2.4.2]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 4.2. Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B [Through Rate] |
| 112 | [23.2.5.2]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 5.2. Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B [Through Rate] |
| 113 | [23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA [Through Rate] |
| 114 | [23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA [Through Rate] |
| 115 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] |
| 116 | [23.22.4.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.11. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door8 way ( 8 incoming 3phase*8 outgoing) [Through Rate] |
| 117 | [23.22.4.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.3. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DBDouble Door 12 way ( 2 incoming and 10 outgoing) [Through Rate] |
| 118 | [23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DBHorizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate] |
| 119 | [23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DBHorizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate] |
| 120 | [23.22.4.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.8. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DBHorizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) [Through Rate] |
| 121 | [23.22.4.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.9. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate] |
| 122 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 123 | [23.22.5.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.2. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Single Pole [Through Rate] |
| 124 | [23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate] |
| 125 | [23.22.6.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.1. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 25 A [Through Rate] |
| 126 | [23.22.6.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.4. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TP RCCB 30ma sensitivity , 25 A [Through Rate] |
| 127 | [23.22.6.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.5. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. FP RCCB 30ma sensitivity , 40 A [Through Rate] |
| 128 | [23.22.8.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.5. SITC Four pole ON LOAD Manual change over switch in SS enclosureof following Ratings 400 amp 415 volts [Through Rate] |
| 129 | [23.23.10]MISCELLANEOUS 10. Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] |
| 130 | [23.23.2.1]MISCELLANEOUS 2.1. Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia [Through Rate] |
| 131 | [23.23.5.4]MISCELLANEOUS 5.4. Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respectup to entire satisfaction of the Engineer-in-charge of work. 50x50 mm [Through Rate] |
| 132 | [23.23.6.1]MISCELLANEOUS 6.1. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable traypainted with powder coating 100 X 50 X 2 mm [Through Rate] |
| 133 | [23.23.6.3]MISCELLANEOUS 6.3. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable traypainted with powder coating 375 X 50 X 2 mm [Through Rate] |
| 134 | [23.23.6.4]MISCELLANEOUS 6.4. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable traypainted with powder coating 600 X 50 X 2 mm [Through Rate] |
| 135 | [23.23.7.1]MISCELLANEOUS 7.1. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable trayCover , suitable for cable tray of 100 X 50 X 2 mm [Through Rate] |
| 136 | [23.23.7.3]MISCELLANEOUS 7.3. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable trayCover , suitable for cable tray of 375 X 50 X 2 mm metre [Through Rate] |
| 137 | [23.23.7.4]MISCELLANEOUS 7.4. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable trayCover , suitable for cable tray of 600 X 50 X 2 mm [Through Rate] |
| 138 | [23.23.8.2]MISCELLANEOUS 8.2. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 4 pair telephone wire [Through Rate] |
| 139 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] |
| 140 | [23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. [Through Rate] |
| 141 | [23.24.2.4]MS STAND, BUS BAR CHAMBER AND PANELS 2.4. Erection of Cubical type Electrical Panels/ Feeder Pillars including necessary mounting Frame made of suitable size I section of required size on existing foundation/platform etc as required Panels/Feeder Pillars having incomers of more than 800 A and up to Four pole 1600 A , Base Mounting frame made of ISMC 200*75*6.2 mm [Through Rate] |
| 142 | [23.24.4.4]MS STAND, BUS BAR CHAMBER AND PANELS 4.4. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 400 amp. [Through Rate] |
| 143 | [23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate] |
| 144 | [23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame. [Through Rate] |
| 145 | [23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entireSatisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia). [Through Rate] |
| 146 | [23.27.3]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof .The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate] |
| 147 | [23.6.6.1]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. [Through Rate] |
| 148 | [23.6.6.2]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia. [Through Rate] |
| 149 | [23.7.6.1]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia. [Through Rate] |
| 150 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] |
| 151 | [23.8.1.12]FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. [Through Rate] |
| 152 | [23.8.1.6]FITTING AND ACCESSORIES 1.6. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type [Through Rate] |
| 153 | [23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate] |
| 154 | [23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate [Through Rate] |
| 155 | [23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate] |
| 156 | [23.8.11.8]FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type [Through Rate] |
| 157 | [23.8.11.9]FITTING AND ACCESSORIES 11.9. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. T.V. Socket outlet modular type [Through Rate] |
| 158 | [23.8.3.4]FITTING AND ACCESSORIES 3.4. Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheetas below 200 mm X 150 mm X 60 mm deep metal box [Through Rate] |
| 159 | [23.8.3.5]FITTING AND ACCESSORIES 3.5. Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheetas below 200 mm X 150 mm X 60 mm deep metal box [Through Rate] |
| 160 | [23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate] |
| 161 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 162 | [24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 163 | [24.1.11]EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. [Through Rate] |
| 164 | [24.1.12]EARTHING AND LIGHTENING ARRESTOR 12. Supplying and laying 6 S.W.G G.I. wire at 0.50 m below ground level from earth electrode including thimbles, soldering etc. as required. [Through Rate] |
| 165 | [24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate] |
| 166 | [24.1.14]EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size. [Through Rate] |
| 167 | [24.1.16]EARTHING AND LIGHTENING ARRESTOR 16. Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers. [Through Rate] |
| 168 | [24.1.17]EARTHING AND LIGHTENING ARRESTOR 17. Providing and fixing testing joints made of 20mm x 3mm thick G.I. strips 125 mm long with 4 nos. G.I. bolts and nuts with washers complete. [Through Rate] |
| 169 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 170 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 171 | [24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but withoutcharcoal or coke and salt) etc. complete as required. [Through Rate] |
| 172 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 173 | [24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate] |
| 174 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 175 | [24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate] |
| 176 | [24.13.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100.400 Sq mm 3.5 core (Arm.) [Through Rate] |
| 177 | [24.13.13]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 13.10 Sq mm 2 core (UnArm.) [Through Rate] |
| 178 | [24.13.14]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 14.10 Sq mm 2core (Arm.) [Through Rate] |
| 179 | [24.13.18]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18.10 Sq mm 4 core (Arm.) [Through Rate] |
| 180 | [24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24.16 Sq mm 4 core (Arm.) [Through Rate] |
| 181 | [24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32.25 Sq mm 4 core (Arm.) [Through Rate] |
| 182 | [24.13.40]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 40.35 Sq mm 4 core (Arm.) [Through Rate] |
| 183 | [24.13.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 48.50 Sq mm 4 core (Arm.) [Through Rate] |
| 184 | [24.13.56]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 56.70 Sq mm 4 core (Arm.) [Through Rate] |
| 185 | [24.13.64]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 64.95 Sq mm 4 core (Arm.) [Through Rate] |
| 186 | [24.13.70]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 70.120 Sq mm 3.5 core (Arm.) [Through Rate] |
| 187 | [24.13.82]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 82.185 Sq mm 3.5 core (Arm.) [Through Rate] |
| 188 | [24.13.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88.240 Sq mm 3.5 core (Arm.) [Through Rate] |
| 189 | [24.13.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94.300 Sq mm 3.5 core (Arm.) [Through Rate] |
| 190 | [24.14.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100.400 Sq mm 3.5 core (Arm.) [Through Rate] |
| 191 | [24.14.30]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 30.25 Sq mm 3.5 core (Arm.) [Through Rate] |
| 192 | [24.14.38]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38.35 Sq mm 3.5 core (Arm.) [Through Rate] |
| 193 | [24.14.54]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 54.70 Sq mm 3.5 core (Arm.) [Through Rate] |
| 194 | [24.14.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88.240 Sq mm 3.5 core (Arm.) [Through Rate] |
| 195 | [24.14.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94.300 Sq mm 3.5 core (Arm.) [Through Rate] |
| 196 | [24.15.7]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in 1 per meter below ground level with sand and bricks with all labour and material including digging and refilling of trench as required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 7.185 Sq mm 3 core [Through Rate] |
| 197 | [24.15.9]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in 1 per meter below ground level with sand and bricks with all labour and material including digging and refilling of trench as required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 9.300 Sq mm 3 core [Through Rate] |
| 198 | [24.16.9]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 9. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 300 Sq mm 3 core [Through Rate] |
| 199 | [24.2.10]LT CABLE 10. Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S. Rod welded/riveted at the top with 10 cm dia 3 mm thick MS plate inscribed with cable word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level. [Through Rate] |
| 200 | [24.2.7.2]LT CABLE 7.2. Supply and erection ofsuitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core [Through Rate] |
| 201 | [24.2.7.3]LT CABLE 7.3. Supply and erection ofsuitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core [Through Rate] |
| 202 | [24.2.7.5]LT CABLE 7.5. Supply and erection ofsuitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core [Through Rate] |
| 203 | [24.2.7.6]LT CABLE 7.6. Supply and erection ofsuitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core [Through Rate] |
| 204 | [24.2.7.7]LT CABLE 7.7. Supply and erection ofsuitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core [Through Rate] |
| 205 | [24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm [Through Rate] |
| 206 | [24.2.8.12]LT CABLE 8.12. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 185 sqmm [Through Rate] |
| 207 | [24.2.8.13]LT CABLE 8.13. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmm [Through Rate] |
| 208 | [24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate] |
| 209 | [24.2.8.15]LT CABLE 8.15. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 400 sqmm [Through Rate] |
| 210 | [24.2.8.3]LT CABLE 8.3. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm [Through Rate] |
| 211 | [24.2.8.5]LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm [Through Rate] |
| 212 | [24.2.8.6]LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm [Through Rate] |
| 213 | [24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm [Through Rate] |
| 214 | [24.2.9.6]LT CABLE 9.6. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 70 sqmm to 150 sqmm Cable 3 to 4 Core [Through Rate] |
| 215 | [24.2.9.8]LT CABLE 9.8. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 400 sqmm Cable 3 to 4 core [Through Rate] |
| 216 | [24.3.3.3]HT CABLE 3.3. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 to 400 sqmm [Through Rate] |
| 217 | [24.3.4.3]HT CABLE 4.3. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 to 400 sqmm [Through Rate] |
| 218 | [24.3.5.4]HT CABLE 5.4. Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 to 400 sqmm [Through Rate] |
| 219 | [24.4.1.3]STREET LIGHT 1.3. 3 metres long 50 mm dia pole duly embedded 0.6 m below ground level. 6 metres long 65 mm dia pole duly embedded 1 m below ground level. [Through Rate] |
| 220 | [24.4.11.1]STREET LIGHT 11.1. Erection of MS/GI/Swaged ( excluding Octagonal ) metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 2.5 metre and up to 4 metre [Through Rate] |
| 221 | [24.4.15.2]STREET LIGHT 15.2. B.S.E.N. 10025 High Masts\"Supply, installation, testing and commissioning of 16 mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip, galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 9/12 nos. luminaire loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 nos. steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete in all respect upto entire satisfaction of Engineer -in-ChargeThickness of Top and Bottom Section = 3 mm & 4mm (minimum)Top Dia = 150 mm and Bottom Dia = 410mmThickness of Galvanization - Top = 65 micron (minimum) andBottom = 85 micron (minimum)\" [Through Rate] |
| 222 | [24.4.2.4]STREET LIGHT 2.4. Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Lightpole 150 cm long, with 30 cm high suitable size pole cap. [Through Rate] |
| 223 | [24.4.8.7]STREET LIGHT 8.7. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge9 Metre Long pole with top dia 100 mm and bottom 200 mm with base plate of size 350 x 350 x 20 mm. [Through Rate] |
| 224 | [24.5.1.1]MISCELLANEOUS ITEMS 1.1. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge.Submersible Copper Cable 3 Core 1.5 sqmm [Through Rate] |
| 225 | [24.5.1.4]MISCELLANEOUS ITEMS 1.4. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge.Submersible Copper Cable 3 Core 6 sqmm [Through Rate] |
| 226 | [24.5.1.6]MISCELLANEOUS ITEMS 1.6. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge.Submersible Copper Cable 3 Core 16 sqmm [Through Rate] |
| 227 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate] |
| 228 | [24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate] |
| 229 | [24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 120/105 mm outer dia/ inner dia [Through Rate] |
| 230 | [24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 145/123 mm outer dia/ inner dia [Through Rate] |
| 231 | [24.5.2.7]MISCELLANEOUS ITEMS 2.7. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 180/150 mm outer dia/ inner dia [Through Rate] |
| 232 | [24.7.7]RCC FOUNDATIONS FOR DG SET 7. 500 KVA DG Set [Through Rate] |
| 233 | [25.3.2]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulationforwater circulation as per specifications. 2. 250 mm dia [Through Rate] |
| 234 | [25.3.3]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulationforwater circulation as per specifications. 3. 200mm dia. [Through Rate] |
| 235 | [25.3.4]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulationforwater circulation as per specifications. 4. 150mm dia. [Through Rate] |
| 236 | [25.3.6]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulationforwater circulation as per specifications. 6. 100mm dia. [Through Rate] |
| 237 | [25.3.7]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulationforwater circulation as per specifications. 7. 80mm dia. [Through Rate] |
| 238 | [25.3.9]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulationforwater circulation as per specifications. 9. 50 mm dia. [Through Rate] |
| 239 | [25.4.2]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 2. 150mm dia. [Through Rate] |
| 240 | [25.4.4]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 4. 100mm dia. [Through Rate] |
| 241 | [25.5.2]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 2. 150mm dia. [Through Rate] |
| 242 | [25.5.4]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 4. 100mm dia. [Through Rate] |
| 243 | [25.5.5]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 5. 80mm dia. [Through Rate] |
| 244 | [25.7.1]Supply, installation, and commissioning of factory/site fabricatedGSSsheet metal rectangular/roundducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 1. Thickness 0.63 mm sheet [Through Rate] |
| 245 | [25.7.2]Supply, installation, and commissioning of factory/site fabricatedGSSsheet metal rectangular/roundducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 2. Thickness 0.80 mm sheet [Through Rate] |
| 246 | [25.7.3]Supply, installation, and commissioning of factory/site fabricatedGSSsheet metal rectangular/roundducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 3. Thickness 1.00 mm sheet [Through Rate] |
| 247 | [25.7.4]Supply, installation, and commissioning of factory/site fabricatedGSSsheet metal rectangular/roundducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 4. Thickness 1.25 mm sheet [Through Rate] |
| 248 | [26.1]Supplying and stackingat site of work well-decayed farm-yard manure from any available source, approved by the Engineer-in-charge including screening through sieve of I.S.designation 16 mm with 5 km lead. [Through Rate] |
| 249 | [26.10]Maintenance of fine grass lawn for one year including fertilizer application, DAP @ 20gm/sqm, urea 40gm/sqm, watering, weeding, top dressing with good earth and manure mixture 2:1 @ 0.01cum per sqm, maintaining fine level, regular mowing and removal of rubbish with all lifts and leads. [Through Rate] |
| 250 | [26.13.3]Digging holes in all kinds of soil, and refilling the same, with the excavated earth, mixed with well decayed farmyard manure (cost of well decayed farm yard manure to be paid separately) 3. Hole 0.75 metre dia and 0.75 metre deep [Through Rate] |
| 251 | [26.13.4]Digging holes in all kinds of soil, and refilling the same, with the excavated earth, mixed with well decayed farmyard manure (cost of well decayed farm yard manure to be paid separately) 4. Hole 0.60 metre dia and 0.60 metre deep [Through Rate] |
| 252 | [26.2]Supplying and stacking of goodquality top layer gardenearth free from debris and weeds,at site including royalty and carriage/lead5 km (good earth measured in stacks will be reduced by 20 % for payment) only for filling of pots and flowerbeds .0.00 0.00 0.00 [Through Rate] |
| 253 | [26.20]Supply and Planting rare andspecimen tree plants in already prepared pits(Ficus starlight 150 cm height , Terminalia 210 cm height, menatalis , Michelia champaca hybrid more than 180 cm height, Cyprus (Golden juniperous ) more than 180 cm height,topiary of 10 to 12 no. well trimmed bolls of more than 30cm size of Ficus nuda, Ficus retusa, Ficus long island , Ficus panda more than 180 cm height, Golden bottle brush , casurina equistefolia , Bottle palm with stem circumference atbase more than 40cm ,Washingtonia palm ofhealthy clear stem height below leaf more Thant 90 cm ) including , fertilizer and insecticides chlorpyriphos 20 ml per pit, planting of 180cm to 210cm tall sapling in position and flooding with water .specie of plant will be decided by engineer in charge. [Through Rate] |
| 254 | [26.21]Maintenance ofspecimen tree for one yearincluding weeding, hoeing , plant protection , watering from Deptt. source ,application of 20 ml chlorpyriphos four times, 0.0289 cum FYM each,50 gm urea and 50 gm DAP twice ,replacement of casualty,disposal of debris and other activities.etc. [Through Rate] |
| 255 | [26.22.1]Planting seasonal flower in beds 1. Supply and planting flower beds including digging 30 cm deep bedand refilling of beds with excavated soil and FYM0.0508 cum per sqm , Fertilizer DAP 50 gms and insecticides chlorpyriphos 10 ml persqm , planting ofF1 hybrid flower saplings to be supplied in tray pots / thumb potsat 20 cm distance from plant to plant and row to row minimum 25 no . plants per sqm [Through Rate] |
| 256 | [26.30]Supplying healthy, well branched, well bloomed and Planting rose beds including digging 30 cm deep bedand refilling of beds with excavated soil and FYM0.0508 cum per sqm , Fertilizer DAP 50 gms and insecticides chlorpyriphos 10ml persqm , planting of hybrid Budded rose saplings to be supplied in earthen pots /20cm x20cmpolybags , planting of sapling at 45 cm distance from plant to plant and row to row and 5 no. plants per sqm [Through Rate] |
| 257 | [26.32]Planting permanent edging plants around beds, lawn or along paths including of digging of trench 45 cm wide to 15 cm depth, refilling the excavated earth, mixed with farm-yard manure, supplied at the rate of 0.9 cum per sqm and supplying and planting hedge/ edgeat 20 cm apart in one or tworows @11no. well trimmedbushy ,multi branched ,30 cm to 45 cm in heightplantsto be supplied in 15 cm x 15 cm poly bags per sqm . [Through Rate] |
| 258 | [26.46]`Supplyingand display specimen pot plant of raphis palm , cephorthia palm 150 cm,areca palm 150-180 cm and similar high quality plants of croton petra 3 plants eachin 45 cm plastic pots with plastic plate for indoor display at site of work. with fresh foliage,90 cm- 180 cmin height` 6-8stems per pot, full of leaves, ,and displaying indoor including the cost of material ( garden soil, coco peat,FYM in 2:1:1 proportion),with ,PVC plate. complete in all respects.` [Through Rate] |
| 259 | [26.50]Supplyingand display of specimen pot plantof Cyprus , Ficus starlight, Topiary of Ficus retusa and similar high quality plants in 45 cm cement pots with plastic plate for outdoordisplay at site of work. with fresh foliage,105 cm- 150 cmin height, 3-4 stems per pot, full of leaves, ,and displaying indoor including the cost of material ( garden soil, coco peat, FYM in 2:1:1 proportion),with ,PVC plate. complete in all respects. [Through Rate] |
| 260 | [26.63.2]Providing and fixing steel tree guard 2. MS circular tree guard with wire mesh, having 4 No. legs of angle iron size 25x25x3mm, 1.80 metre. height, 3 No rings of M.S Flats of 25 x 6 mm, 60cm dia and fixing of wire mesh size 50x75mm. Tree guard in two halves bolted together with 8mm dia & 30 mm long bolts, and fixing 250 mm X 100 mm iron plate, fixed in ground with 1:2:4 cement concrete, complete in all respects. Minimum weight should be 23 kgs [Through Rate] |
| 261 | [26.9.4]Turfing lawns with fine grassing ( selection no.1/ Bermuda and Mexican/Neelgiri grass )including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying of selection no. 1 / Bermuda doob grass and Mexican/Neelgiri grass roots, including supplying and spreading of farmyard manure at the rate of 0.60 cum per100 sqm, maintenance till weed free turf is formed 4. Providing and fixing Selection no. 1 grass turf with earth 50mm to 60mm thickness and ramming with required wooden tools, rolling with light roller to make the surface smooth and even [Through Rate] |
| 262 | [28.12]`Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achievea minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties:1) Elongation: )400% as per ASTM D 4122) Tensile Strength : 2.5 N/mm2 as per ASTM D 4123) Adhesion in-peel test: )50 N as per ASTM C- 8364) Recovery from 350% elongation : 95% as per ASTM D 4125) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr6) Initial Hardness Shore A : min 60 as per ASTM D 22407) Root resistant : protection screed requiredSystem includes supply , application and termination of coating all complete as per the manufacturer methodology.Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with nonshrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer’s recommendations. Providingandapplyingliquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achievea minimum DFT of 1.3 mm. (Fibre cloth/fleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done300 mm above vertical wall by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar. Membrane shall be protected using 8mm thick dimple board for protection as per manufacturer`s recommendation followed by backfilling. The rates are inclusive of surface preparation, crack filling, injection grouting at honeycombed areas, coving, priming all complete as per manufacturer methodology but excluding the cost of protection board. ` [Through Rate] |
| 263 | [28.15]Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. [Through Rate] |
| 264 | [28.17.1]Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 1. With average thickness of 120 mm and minimum thickness at khurra as 65 mm. [Through Rate] |
| 265 | [28.20.1]Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 1. For vertical surface two coats @ 0.70 kg per sqm [Through Rate] |
| 266 | [28.8]`Supplying and applying waterproofing treatment for `Raft Slab` by using 1.2 mm thick fully bonded HDPE sheet membrane complying to BS8102:2009/ IS 16471-2017. The HDPE shall be virgin HDPE and not recycled, thickness of bare HDPE shall not be less than 0.8 mm coated with pressure sensitive adhesive layer and a trafficable granular top layer.The HDPE membrane shall have the following typical properties:1. Tensile Strength : )27 Mpa ( as per ASTM D412)2. Puncture Resistance: )1000N±5% (as per ASTM E154)3. Elongation: )500%4. Peel adhesion to concrete: )1500N/m (as per ASTM D903 Modified)5. Resistance to Hydrostatic Head: )70 metre (as per ASTM D751-06(2011)6. UV exposure test (60 days): No change7. Lap Joint Strength : 1500N/m (as per ASTM D1876)HDPE Membrane shall be installed over the entire PCC area with standard 75 mm selvedge laps and end laps overlaid with HDPE Sealed Tape as per manufacturer`s instructions. The rates are inclusive of supply and installation of membrane as per manufacturer methodology.The rates are inclusive of surface preparation, injection grouting at honeycombed areas all complete as per manufacturer methodology. ` [Through Rate] |
| 267 | [3.1.2]By Mechanical Transport including loading, unloading and stacking2. Earth [1km] |
| 268 | [30.82.1]Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness up to 6` (six inches) for passing drain pipe and repairing the hole after insertion of drain pipe etc. including finishing-complete so as to make it leak proof. 1. Drain pipe of 150mm internal dia [Through Rate] |
| 269 | [30.82.2]Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness up to 6` (six inches) for passing drain pipe and repairing the hole after insertion of drain pipe etc. including finishing-complete so as to make it leak proof. 2. Drain pipe of 100mm internal dia [Through Rate] |
| 270 | [33.12]Supplying, filling, spreading and levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. [Through Rate] |
| 271 | [33.13]Supplying, filling, spreading and levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. [Through Rate] |
| 272 | [33.14]Supplying, filling, spreading and levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge. [Through Rate] |
| 273 | [33.18.3]Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 3. 200 mm dia [Through Rate] |
| 274 | [33.19]Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by `V` notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-charge. [Through Rate] |
| 275 | [33.6.1.2]Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. 1.2. All types of soil350 mm dia [Through Rate] |
| 276 | [33.9.3]Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 3. 200 mm nominal size dia [Through Rate] |
| 277 | [4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate] |
| 278 | [4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate] |
| 279 | [4.17]Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). [Through Rate] |
| 280 | [4.2]Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. [Through Rate] |
| 281 | [4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate] |
| 282 | [6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 283 | [6.1.3]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 3. 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 284 | [6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 285 | [6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 286 | [6.22.1.3]Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer forall leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1.3. All works above plinth and up to floor IV level :M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) [Through Rate] |
| 287 | [6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate] |
| 288 | [6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate] |
| 289 | [6.26.2]Extra for providing richer mixes up to plinth and at all floor levels. 2. Providing M-35 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement content considered in M-35 is @ 350 kg/ cum) [Through Rate] |
| 290 | [6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate] |
| 291 | [6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. [Through Rate] |
| 292 | [6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate] |
| 293 | [6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate] |
| 294 | [6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate] |
| 295 | [6.30.7]Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases [Through Rate] |
| 296 | [6.32.1]Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) [Through Rate] |
| 297 | [6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate] |
| 298 | [6.39.1]Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] |
| 299 | [7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate] |
| 300 | [7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 301 | [7.28.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) [Through Rate] |
| 302 | [7.30]Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. [Through Rate] |
| 303 | [8.26.2.1]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.1. Granite of any colour and shadeArea of slab up to 0.50 sqm [Through Rate] |
| 304 | [8.27.2]Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work [Through Rate] |
| 305 | [8.28]Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. [Through Rate] |
| 306 | [8.6.2]Providing and fixing cramps of required size and shape in RCC/ CC / Brick masonry backing with cement mortar 1:2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). 2. Stainless steel cramps [Through Rate] |
| 307 | [8.7.1.2]Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 1.2. Wedge expansion typeFastener with threaded dia 10 mm [Through Rate] |
| 308 | [9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate] |
| 309 | [9.33]Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm ( plus0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. [Through Rate] |
| 310 | [9.47.2]Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spacedjoints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 2. GI Metal Ceiling Lay in perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. [Through Rate] |
| 311 | [9.57.1]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1. 75 mm diameter [Through Rate] |
| 312 | [9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate] |
| 313 | [9.57.3]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter [Through Rate] |
| 314 | [9.58.1.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.2. Coupler 110 mm [Through Rate] |
| 315 | [9.58.1.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.3. Coupler 150 mm [Through Rate] |
| 316 | [9.58.2.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 2.2. Single push fit Coupler 110 mm [Through Rate] |
| 317 | [9.58.2.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 2.3. Single push fit Coupler 150 mm [Through Rate] |
| 318 | [9.58.3.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.2. Single tee with door110x110x110 mm [Through Rate] |
| 319 | [9.58.3.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.3. Single tee with door150x150x150 mm [Through Rate] |
| 320 | [9.58.4.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 4.3. Single tee without door150x150x150 mm [Through Rate] |
| 321 | [9.58.5.1]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.1. Bend 87.5°75 mm bend [Through Rate] |
| 322 | [9.58.5.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5°110 mm bend [Through Rate] |
| 323 | [9.58.5.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5°150 mm bend [Through Rate] |
| 324 | [9.58.6.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.2. Shoe (Plain)110 mm Shoe [Through Rate] |
| 325 | [9.58.6.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.3. Shoe (Plain)150 mm Shoe [Through Rate] |
| 326 | [9.62.1]Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 1. 100 mm diameter [Through Rate] |
| 327 | [9.62.2]Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 2. 150 mm diameter [Through Rate] |
| 328 | SITC of Commercial grade 55 inchDISPLAY UNIT having following technical specification 1.Display Size: 55 inches or more 2.Resolution and built in:3840 x 2160 (UHD) ,4K 3.AUDIO: Advanced Audio4.Built in :Bluetooth Connectivity (optional), built in Wi Fi, 5.Built in Speaker:20W 6.Others:HDMI X 3, DP X 1,USB X1 ,RJ45 X 1 , Digital audio out. 7.Brightness:300 cd/m2 or better8.Dashboard feature:SNMP support to take control of display to check, Diagnose and Corrections through LAN network, Wake on LAN9.Operation Temperature:0 °C to 40 °C or better, humidity 80% 10.Warranty: 3 years onsite 11.Mounting:Wall mount and table mount both 12.Display Type:24x7 working compatibility13.Certificates and Approvals: BIS, ISO 9001, CB/UL |
| 329 | Providing and applying 12-15mm ready mix/ ready plaster RP cement based plaster mortar having density 1500-1600 per m cum and compressive strength in 28 days 10-12 MPA on cement concrete/reinforcement concrete/brick work/AAC Block of approved make as per satisfaction of Engineer in Charge..... |
| 330 | Supply and Erection of 24-port 19` 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19` 1U straight Patch Panel, 24-port,Should have integral cable management Metal shelf,Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated. |
| 331 | Providing and fixing of Woven vinyl carpet floorings series with roll dimensions of 1.8/2mtr meters width and length of 20 meters or Tiles size as per company standard should be approved by architech. 2.50-2.80 mm thickness to laid on hard, levelled, smooth and moisture free sub floor. Woven Vinyl flooring should have traffic classification 33 and weight of 2.7-3.5 kg/m2. Flooring should have caster chair EN-985 tested with color fastness of more than 6. It should be ASTME662 qualified on Smoke density test. Product must be fire rating of the product should be Bfl-S1. Any Joints in flooring rolls should be sealed with cold welding.As per approved shade and colour as per the satisfaction of the Architect.MAKE: LG/ Woderfloor. |
| 332 | Supplying, installation, testing and commissioning of repeater panel with 320 character/TouchscreenLCDdisplay with inbuilt reset,acknowledgeand silence switches complete as required. |
| 333 | Supplying, installation, testing and commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc. as required Supplying, installation, testing and commissioning of intelligentaddressable programmable sounder complete as required. |
| 334 | Supplying, installation, testing and commissioning of fault isolator complete with base as required. |
| 335 | Supplying, installation, testing and commissioning of addressable beam detector with short circuit isolator (inbuilt or separate complete with emitter and receiver including connections with remote test features etc. complete as required. |
| 336 | Supplying, installation, testing and commissioning of fire fighter telephone handset complete as required. |
| 337 | Supplying, installation, testingand Commissioning of intelligent interface unit BAC net/ Modbus protocol i.e. supplying communication links between building management systemand fire alarm control panel complete as required. |
| 338 | Supplying, installation, testing and commissioning of fire fighter phone jack complete as required. |
| 339 | Supplying, installation, testing and commissioning of 6 inches dia, 2 watts, 70/ 100 volts ceiling speaker complete as required. |
| 340 | Supplying and laying of 2x 1.5 sqmm fire survival armored cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armoring and LSZHoutersheath complete as required. |
| 341 | CONTROL PANELSFabrication, supply, Installation testing and commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter- connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump pressurization pump and diesel pump set complete as per CPWD specification with following in comingandOutgoings,suitablefor operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP42 as required:INCOMING630A, 50kA 4 Pole MCCB, Ics=100%Icu ratingDigital Voltmeter 0-500V with selector switchAmmeter (0-630 A) with selector switch and CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lampsSet of Copper Bus Bar 800AmpsOUTGOING(Note: All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)MAIN FIRE PUMP250 A, 50kA TPN MCCB, Ics=100% Icu,with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation. selector switch for local/remote, auto/manual/OFF operation.JOCKEY PUMP125 A, 50kA TPN MCCB, Ics=100% Icu,with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising- Automatic/Manual selector switch and 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual modeIndicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indicationBattery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC. AmmeterAll standard relays and accessories for automatic operation of diesel engine.SYSTEM CONTROLLERDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification. |
| 342 | S.I.T.C. of auto glow exist sings and indication signs of size 12” x 4” and attack fire, DP indication at every exit point, fire point, fire extinguisher compete in all respect. |
| 343 | Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the nonvolatile memory (EPROM), power supply unit (230 t 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for BMS system with open protocolBAC net/ModbusoverIP complete as per specifications:Ten Loop Panel |
| 344 | Providing, laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding. excavation and providing cement concrete blocks as supports anticorrosive treatment with coaltar/asphalt tape as per IS 10221. Refilling the trench etc. of following sizes complete as required.200 mm dia (Wall Thickness = 6.3 mm) |
| 345 | Providing, laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding. excavation and providing cement concrete blocks as supports anticorrosive treatment with coaltar/asphalt tape as per IS 10221. Refilling the trench etc. of following sizes complete as required.150 mm dia |
| 346 | Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hosepipe coupling as required:Stainless Steel ( G- 304) |
| 347 | Providing and fixing flow switch in following sizes M.S. pipe including connection etc. as required.100mm dia |
| 348 | Providing and fixing flow switch in following sizes M.S. pipe including connection etc. as required.150mm dia |
| 349 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitablediaMSpipeconnection conforming to IS 904 as required:4 way-150 mm dia MS Pipe |
| 350 | Providing, fixing, testing and commissioning of 15mm dia quartzite bulb type sprinklers of rating 68 degree centigrade with required accessories.Horizontal side wall sprinkler |
| 351 | (A) Supplying. installation, testing and commissioning of electric driven pressurization pump suitable for automatic operation and consisting of following, complete in all respects, as required: ( Jockey Pump)(B) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS: 1520.(C) Suitable HP squirrell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply withIP55classofprotectionfor enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS:325.(D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required(E) Suitable cement concrete foundation duly plastered and with anti-vibration pads.180 LPM at 88 m Head. |
| 352 | (A) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitableforautomaticoperation and consisting of following, complete in all respects, as required(B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520(C) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325(D) M.S. fabricated Common base plate, coupling, coupling guard foundation bolts etc. as required(E) Suitable cement concrete foundation duly plastered with anti-vibration pads.(Note: The head of the pump is selected in a manner so as to give a minimum3.5kgf/cm2 pressure at the highest/ farthest point.)2280 LPM at 70 m Head |
| 353 | (A) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)(B) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(C) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts electric starting equipment, diesel tank exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(D) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required(E) Suitable cement concrete foundation duly plastered and with anti-vibration pads.(Note: The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/ farthest point.)2280 LPM at 70 M Head |
| 354 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required.50mm dia |
| 355 | Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:50mm dia |
| 356 | Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:80mm dia |
| 357 | Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:100mm dia |
| 358 | Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:150mm dia |
| 359 | Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia |
| 360 | Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:250mm dia |
| 361 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/I$ 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:25mm dia |
| 362 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:32mm dia |
| 363 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:40mm dia |
| 364 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:50mm dia |
| 365 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:65mm dia |
| 366 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:80mm dia |
| 367 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:100mm dia |
| 368 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:150mm dia |
| 369 | Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:250 mm dia(wall thickness 6.3 mm) |
| 370 | S/E of 70/72W LED Street light luminaire with powder coated pressure die-cast aluminium housing,high efficiency LED, toughened glass with IP66 protection, , working hour minimum 50000 hours, operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. [3Q] |
| 371 | Supply and erection of LED Downlighter 12 watt, operation on single phase AC supply complete in all respect up to the entire satisfaction of Engineer- in - charge of the work including making necessary connections etc. [3Q] |
| 372 | S/E of stay set suitable for 9/11 mtr long PCC pole made out of 7/8 SWG GI wire with U type MS rod 5/8`dia duly threaded by means of angle iron of size50mmx6mmx6mm, 30 cm long and 6 ft. long MS rod5/8` dia, 5` buried in the ground after fixing with cross channel of size 75mmx40mmx60cm. The stay wire will be binded on the top of the pole with the help of suitable size of double U type MS clamps and tied with nuts and bolts. the stay wire shall be insulated in the middle pointwith the help of insulator and complete with one coat of red oxide with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.ii) With Disc insulator (for H.T. Pole) [3Q] |
| 373 | SUPPLY and ERECTION of -11 meter long PCC Pole 152 mm x 203 mm at top and 152 mm x 368 mm at bottom with working load of 360 Kg. burried 2.20 m in ground. [3Q] |
| 374 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required,(i) Stainless Steel (Grade 304) [3Q] |
| 375 | Supply and Erection of hose box double door(750*600*250 mm) suitable for 2 No. hose pipe 15 meter, 1 No. short branch pipe complete in all respect.[3Q] |
| 376 | Providing and Fixing of ABC Type 6 kg (Stored Pressure) Fire Extinguisher filled with Mono Ammonium Phosphate Powder MAP 50% Confirming to ‘IS 4308’, Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose and Nozzle and Epoxy Polyester Powder Coated Mild Steel body, Fire Extinguishers As per ‘IS 15683 : 2018’ ISI Marked.[3Q] |
| 377 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bond with GI wire, rivets etc. conforming to IS 636 (Type-A) as required: Stainless Steel (Grade-304). [3Q] |
| 378 | Supply and erection of LED light 2` x 2` 36 Watt, operation on single phase AC supply upto 35000 working hour complete in all respect up to the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc.[3Q] |
| 379 | Supply and erection of 25 Ltr. commercial RO plus UV, Fully automatic with auto cut off RO plus UV Water Purification system 25 ltr/ hr capacity complete with all labour and petty material required i/c making necessary connections upto entire staisfaction of Engineer-in-Charge of the work[3Q] |
| 380 | S/E OF WATER COOLER OF SS BODY WITH 150 LTR. STORAGE and COOLING CAPACITY WITH ALL PETTY MATERIAL AS PER BRAND LIST.[3Q] |
| 381 | PROVIDING AND FIXING HAND SHOWER (HEALTH FAUCET) WITH 8MM DIA 1 METER LONG FLEXIBLE TUBE AND WALL HOOK CAT NO. (ALD-CHR-573) make Jaquar complete in all respect (Updated 05.03.2024) |
| 382 | PROVIDING AND FIXING 12 INCH TOWEL RAIL (GRAB BAR) CAT NO. (AQN- CHR-7711B) make Jaquar complete in all respect (Updated 05.03.2024) |
| 383 | PROVIDING AND FIXING TOWEL RING CAT NO. (AQN- CHR-7721) make Jaquar complete in all respect (Updated 05.03.2024) |
| 384 | PROVIDING AND FIXING Soap Dish CAT NO. (AQN-CHR-7731) make Jaquar complete in all respect (Updated 05.03.2024) |
| 385 | Supply and Erection of 2 Core 1.5 Sq mm Speaker Cable Make Havells/Polycab/Finolex.[3Q] |
| 386 | Supply and Erection of 10 mtr HDMI Cable Make Kramer / Manhattan/ AMX 3Q] |
| 387 | S/E LED 18 W downlighter/square /round surface/recess mounting white colour working hour minimum 35000 hours operations on single phase AC supply complete in all respect upto the entire satisfaction of engineer in charge of the work including making necessary connection etc.(3QN) |
| 388 | Supply and erection of Fire Extinguisher ISI marked CO2 type of 4.5 Kg capacity as per IS :7285 duly erected/ hags on wall with hooks i/c the cost of hook, screws etc. with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in Charge of the work. /[3Q] |
| 389 | Supply, Installation, Testing and Commissioning of Outdoor Junction box PVC. |
| 390 | Supplying. Installation, testing and commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required. |
| 391 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve and nozzle.(c) Drum and brackets for fixing the equipment`s on wall.(d) Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. (DSR2022/18.17.1)30 m size |
| 392 | Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 393 | Providing and fixing Auditorium chair complete in all respect (Warranty period of Five years include AMC of the product). The specifications are as under:- Providing and arranging auditorium chairs that are aesthetically pleasing, cozy, and well-designed. The back will be composed of 15mm plywood with PU foam, and the seat will be made of 12mm thick hot- pressed plywood with HR polyurethane foam upholstered in fire-resistant fabric tapestry. There must be a seat sliding mechanism on the chair. The armrest needs to have a cup holder and be composed of PP. Every metal component needs to have a minimum 40 micron black powder coating applied to it. The grouting plate, which measures 170 mm by 85 mm by 3.5 mm in thickness, must be welded. The dimensions of the seat are 470±10 mm (W) x 440±10 mm (D), the back is 820±10 mm (H) from the seat x 540±10 mm (W), and the total height is 1040±10 mm. The chair must be Grennguard (Ul), indoor air quality (IAQ), Confederation of Indian Industry (CII) certified. (3Q). |
| 394 | Providing and fixing Fully Insulated Non Metallic Wooden Fire door at all levels. Wooden fire door should carry 120 minutes Insulation properties. Main Door frame shall be Single rebate profile of section 120 x 70 mm made out of Hard wood - Red merandi / Ivory Coast (2nd class ) as per requirement with factory made groove of suitable size so as to accommodate Fire and smoke seal of size 20x4mm . The frame must be primed with Fire retardant primer. Wooden shutter must be of minimum 52mm of thickness finished with commercial ply on both faces. The commercial ply must be finished with Fire retardant primer. The Commercial ply may also be pasted with Laminate in desired shade (payable in extra item). The composite thickness of the core insulation will be 44mm consists of Calcium Silicate boards of approved make and treated wool Insulation material. The shutter should be provided with heat activated intumescent fire seal strip of size 20mm x 4 mm mounted in the suitable grooves all three sides except bottom provided on Exposed OR concealed wooden lipping . Vision panels wherever required should be of 120 minutes fire rated clear non wired type. All hardware’s, Fasteners and FR Glass shall be payable in Extra item. Door shutter provided with commercial ply on both faces with 1mm Thick Regular SF grade Factory pasted Laminate on both faces and Main frame made out of hardwood frame. Frame primed with Fire retardant primer.FIXTURES OF DOORS:(A) Supply and fixing of SS Ball Bearing Hinges of size 100 x 75 x 3mm complete with SS Screws of BB1953 Becker Fire Solutions / DORMA 3090F / GEZE Make (4 No’s per panel), (B) Supply and fixing of anchor fasteners of HILTI/ FISHER/ Equivalent of M10X120mm length. (C) Supply and fixing of door closers of BLC-604 Becker Fire Solutions/ TS-89 DORMA / GEZE TS 2000 Series Make. (Except shaft door). (D) Supply and fixing of Stainless Tower Bolt 300mm Long for Double leaf door of height up to 2100mm of Becker Fire Solutions. / Dorset Make with necessary screws as required. (E) Supply and fixing of Stainless Tower Bolt 600mm Long for Double leaf door of height up to 2400mm of Becker Fire Solutions. / Dorset / EQ make with necessary screws as required. (F) Supply and Filling the gap between wall and Door frame by using silicone sealant and Wool insulation on both side of the door(3Q) |
| 395 | SITC of 22U equipment rack with provision for housing all control equipment with front and rear door, blower for cooling and proper locking arrangements and as per the specifications, complete in all reapect upto the entire satisfaction of engineer in charge of the work.Complete in all respect as per Directions of Engineer-in-Charge. |
| 396 | SITC of LED `COB` WASH LIGHT for CYCLORAMA: using 60 Nos.x 4w RGBW Hi-Power 3-in-1 LEDs : IP-65 rated : Power AC 240V / 50Hz 240W : Lamp Life: )50000 hours : Beam Angle: 60°: 0-100% electronic linear Dimmer, 1-10 times/sec strobe: DMX-512 signal, 6 DMX Channels : Al.die-cast housing : s/w Power and DMX data link cables: 4-leaf Barndoors and suitable clamp. Complete in all respect as per Directions of Engineer-in-Charge. |
| 397 | Gigabit Managed Network switch with PoE. Complete in all respect as per Directions of Engineer-in-Charge. |
| 398 | SITC of 16 Port Gigabit switch.Complete in all respect as per Directions of Engineer-in-Charge. |
| 399 | SUPPLY AND ERECTION of water cooler SP body with 150 ltr/hr Cooling Capacity and 150 ltr storage capacity complete in all respect /c all labor and petty material. [3Q] |
| 400 | Providing and Fixing of installation control valve with turbine type automatic Alarm Gong to be connected with control valve, drain and test valve as per manufacturer`s specifications complete. (i) 150mm dia. |
| 401 | Supplying, Laying, Testing and Commissioning ofISI marked BUTTERFLY VALVE PN 1.6, with Stainless Steel seal duly ISI marked completewith rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. (i) 25MM |
| 402 | Supply, installation, testing and commissioning of plug in typeanalogue addressable Multicriteria Detector (Heat cum Smoke) with soft addressing feature including the cost of base plate with twin LED for 360° view complete as per specification. |
| 403 | Providing and Fixing of Control Module to control the other systems such as elevators, automatic doors etc |
| 404 | Providing and Fixing of Monitor Module to activate the fire fighting system, Exhaust fans,etc |
| 405 | `Proving and fixing ISI Marked Dual Type Non-return valves flanged end class PN-1.6 as per IS:5312/2004in pipe lines includingjointing and cost of Nut Bolt , rubber insertion etc complete(i) 150mm dia(Dual Type NRV) |
| 406 | Supplying, Installation, Testing and Commissioning ofcast iron flanged Y type strainer with stainless steelmesh in PN-1.6 including cost of Nut Bolt , rubber insertion complete in all respects.(i) 250 mm dia |
| 407 | Supply and Erection of Post Top lantern 25 watt suitable for 220 V, 50 Hz supply. Make as per HPHC Brand list |
| 408 | SITC of Industrial type pressure gauges with gun metal / brass valves complete in all respect |
| 409 | Providing and fixing in position CP jali of Heavy quality, 100mm dia of standard make approved by Engineer-in-charge complete in all respect (3Q). |
| 410 | Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect )110mm dia Plain Bend. |
| 411 | Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe (110mm dia) class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect ) Door tee. (3Q) |
| 412 | Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe (110mm dia) class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect ) Plain tee. (3Q) |
| 413 | Providing and fixing 50mm wide colour contrast `EDGE STRIPS` self addhesive on treads of stair cases to help people with visual diabilities and elederly even in dim light condition complete in all respect to the entire satisfaction of Engineer-in-charge (NS) (Latest 3 Nos Quotations) |
| 414 | Providing and fixing `L` shaped `Grab Bar` 600mm long and 30mm 40mm thick dianmeter of 18-gauge made up of `stainless steel` of International Standard in the toilets to make them `Unisex Toilet` for visually impaired visitors as per design / specification and guidelines complete in all respect to the entire satisfaction of Engineer-in-charge (NS) (Latest 3 nos quotations) |
| 415 | Providing and Fixing of Emergency Assistance Alarm System for toilets (Wireless) having 3-way splitter unit i.e. Pull Cord for differently abled persons/ Senior Citizens, reset system and Over Door Alarm having compact design, High Visibility and as per harmonized guidelines laid by the Government. (NS) (Latest 3 nos quotaions) |
| 416 | SITC of ERD unit having 30 KV Capacity for 13 passenge lift having 3Phase in 3Phase Out ,With inbuilt isolation transformer ,Micro controller based IGBT technology ,Advanced technology: DSP based controller for power and monitoring ,True online dual conversion design , 30nos.*12V/42AH for 30Kva,Heavy duty angle iron racksplusUNINVYN fire retardant copper battery interlinks,Wireless RF based voice guided display unit with transmitter, signal booster and receiverComplete in all respect. |
| 417 | Supply, Installation, Testing and Commissioning of Analogue Addressable type Smoke Detector with Visible bi-color LEDs for 360 deg having Rotary, decimal addressing system in the range of 01-159, complete with standard base, as required, complying to EN54 and LPCB/UL. |
| 418 | Supply, Installation, Testing and Commissioning of Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Switches for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/UL. |
| 419 | Supply and Erection of Commercial Mineral RO system of 50 Liter/ hr. water Purification Capacity i/c fixing on wall with all petty material and labour reqd. operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. |
| 420 | P/FSoap Dispenser with Glass Bottle (CAN-1135N)Jaquar make or equivalent. |
| 421 | P/F Toilet Roll Holder with Stainless Steel Flap (CAN-1153S)Jaquar make or equivalent. |
| 422 | P/F Wall Mixer Non-Telephonic Shower Arrangement with Connecting Legs andWall Flanges (SOL-6219)Jaquar make or equivalent. |
| 423 | Providing and fixing SWR UPVC SWR P-trap (DS) 110x110mm dia complete in all respect. |
| 424 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical confirming to IS:1520 (C) Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325. (D) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered and with anti-vibration pads. 900 LPM at 35 m Head |
| 425 | Supply and fixing Air vessel made of 250mm dia x 1200mm high with air release valve top and flanged connection to riser, drain arrangement with 25mm dia gunmetal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 426 | Supply, Installing, Testing and commissioning of Hard Disk 10TB for NAS storage WD Ultra Star. |
| 427 | Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor unitsin connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating thatthe piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom)(I) 34.9 mm OD (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 428 | Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating thatthe piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom)(I) 28.6 mm OD (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation... |
| 429 | Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom) ..(I) 22.2 mm OD (ins(Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation. |
| 430 | Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating thatthe piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom)(I) 19.1 mm OD (Hard drawn) with tube thickness 1.2 mm with 13 mm thick insulation.. |
| 431 | Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating thatthe piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom)(I) 15.9 mm OD (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation.. |
| 432 | Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating thatthe piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom).(I) 9.5 mm OD ((Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation.. |
| 433 | Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF /VRV system etc. complete in all respects duly insulated with Class `O`closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that thepiping layout is as per company specifications for full functioning of the system. ..41.3 mm OD (insulation = 19mm) |
| 434 | SITC of Master Control Unit inbuilt A/v alarm Control Panel along with sounder cum strobe of 24VDC operated red colour MS housing , 2 NO/NC potential free relay contact for Main Fire Alarm. Modbus for BMS Integration. Gas discharge led indicator, battery led indicator, system status Led indicator, AC power ON Led indicator... |
| 435 | Supply of Wall Fan 16` Sweep ( 400mm)oscilating pipe light duty complete with built-in regulater, blade, jali etc. .Make:- as per HPHC approved Brand List WITHOUT GST.. |
| 436 | Supply, Installation, Testing and Commissioning of 5 MP BULLET Camera 30 mtr IR with below mentioned minimum features: Type of Camera: Bullet Image Sensor: 1/2.8 ` progressive Scan CMOS Resolution and frame rate: 5 MP @ 20fps OR Better Minimum Illumination: 0.05 Lux or better, F 1.6 or better Video Compression (Minimum): H.264, H.265, or better Wide Dynamic Range: Real/True WDR (120 db or more) Storage: Including 256 GB SD card- class 10 Audio Recording: Including internal and External Mic IR: 30 mtr. Or higher Network Protocol: TCP/IP, UDP, IPV4, IPV6, HTTPS, SNMP, DHCP Enclosure: IP67, IK10 Standards: BIS, UL/CE/FCC Power: PoE Reset Button: Required Lens Type: Lens Type: 2.8- 8mm or better motorized lens Lens: F 1.6 or better Signal-to-Noise Ratio: 50 dB or more System Capability: Should be ONVIF Profile G, S and T Note : Quoted Model should be listed on ONVIF website and CCTV OEM should not be blacklisted by ONVIF. Operating Condition: 0 °C to 55°C, humidity 80% (max) VMS Support: Camera shall support open-source VMS Additional Features: Defog, BLC,HLC Video Analytics: Motion Detection, Tampering Video Encryption: AES/TLS/SRTP NDAA Compliant: Yes.. |
| 437 | Supply, Installation, Testing and Commissioning of 5 MP DOME Camera 30 mtr IR with below mentioned minimum features: Type of Camera: Dome Image Sensor: 1/2.8 ` progressive Scan CMOS Resolution and frame rate: 5 MP @20fps OR Better Minimum Illumination: 0.05 Lux or better, F 1.6 or better Video Compression (Minimum): H.264, H.265, or better Wide Dynamic Range: Real/True WDR (120 db or more) Storage: Including 256 GB SD card- class 10 Audio Recording: Including Mic IR: 30 mtr. Or higher Network Protocol: TCP/IP, UDP, IPV4, IPV6, HTTPS, SNMP, DHCP Enclosure: IP67, IK10 Standards: BIS, UL/CE/FCC Power: PoE Reset Button: Required Lens Type: Lens Type: 2.8- 8 mm motorised lens or better or equivalent Lens: F 1.6 or better Signal-to-Noise Ratio: 50 dB or more System Capability: Should be ONVIF Profile G, S and T Note : Quoted Model should be listed on ONVIF website and CCTV OEM should not be blacklisted by ONVIF. Operating Condition: 0 °C to 55°C, humidity 80% (max) VMS Support: Camera shall support open-source VMS Additional Features: Defog, BLC Video Analytics: Motion Detection, Tampering Video Encryption: AES/TLS/SRTP NDAA Compliant: Yes.. |
| 438 | Supply, and Erection of 1200 mm sweep, BEE 5 star rated (BEE), ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 7.5, Air delivery minimum 225 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 8%, electronic regulator unit for speed control and all remaining accessories including safety pins, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete with minimum 24 months of warranty as required.. |
| 439 | Supply, installation, testing and commissioning of 1100 mm (nominal size), 20 watt LED batten luminaire in PC housing with minimum light output 100 lumen/watt and Toatl system lumen )2000 lumen THD (20%, PF )0.95. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance.LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.(as per HPHC Brand list) ( Make-Phillips / Havells / Wipro / Bajaj) |
| 440 | Supplying of10 Watt, 0.5 Metre, LED Bollard Light fittings alongwith its all accessories like potted electronic LED driver made out of Die Cast base and opal acrylic diffuser having IP-65 protection and mechanical impact resistance rating of lk)=07. The fixture should have a minimum system efficacy of )100 lumen/Watt.The fixture driver should have an operating voltage range of 140-270 Volt, surge protection of )=10KV, PF))0.90, THD (20%. The fixture shall be designed for a system life of 50,000 hours. LM 79 andLM 80reports need to be submitted from a NABL/UL accredited lab to verify above parameters.(as per HPHC Brand List) (Make-Phillips / Havells / Wipro / Bajaj) |
| 441 | Supply, installation, testing and commissioning of 9.6w / mtr led strip with AC to DC Driver, Operating voltage 140-270v, cct 3000k, PF )0.5. The fixture shall be designed for a system life of 30,000 hours.LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. (Approved Makes : Philips /Havells/ Wipro /Bajaj) |
| 442 | Supply, Installation, Testing and Commissioning of 1.5 TR, 5 star, Inverter type, Wall mount `Split Air-conditioning unit `, single phase consisting of condensing indoor unit, outdoor unit of copper coil, MS stand, copper wound digital stabilizer 4 KVA , 160V -270V , copper refrigerant piping and cabling between indoor and outdoor unit upto 3 meter etc. complete in all respect i/c making repair of wall, floor and roof in original shape caused by making holes and chases etc. |
| 443 | Supply, installation, testing and commissioning of NVR, 64 Channel , with Incoming and out going bandwidth of 320 Mbps each , 8 SATA port , with minimum 40 TB (4 X 10 TB) storage with below mentioned minimum features: supporting channel :64 channels Bandwidth :320 Mbps (Incoming)/320 Mbps (Outgoing) Recording Resolution: UP to 8 MP Video Output:1 or 2 HDMI Ports USB interface:1xUSB 3.0, 2XUSB 2.0 Raid :RAID 0/1/5/6/10 Minimum Storage :Minimum 8 SATA ports (Support up to 10TB Each SATA Port) Alerts: Generate alerts for camera or equipment malfunction and replacement, HDD failures, HDD tampering, etc. Auto start/ Resume :should be capable of auto start/Resume operations post power fluctuation/ failure Access Management: Feature to limit access to storage data with access management Connectivity Interface:2 Nos. x 10/100/1000 Base-T Lan Port Backup and other Interface:1 e-SATA Port Protocols: NTP, SNMP Operating Condition:0°C to 55°C, humidity 80% (max) Alarms I/O: Minimum - 1 Alarm input ports and 1 Alarm Output Ports System Capability: Should be ONVIF Profile G, S and T Note: Quoted Model should be listed on ONVIF website and NVR OEM should not be blacklisted by ONVIF. Certifications :BIS Certified, UL/CE/FCC Additional feature :Auto sync - SD card to NVR, Auto resume ,VMS: Must have pre-loaded VMS, ONVIF complaint. |
| 444 | Supplying of 200 W LED Flood light luminaire, housing made up of die cast aluminium/ aluminium alloy, complete with driver, LEDs with Optic Lenses, toughened glass cover and mounting bracket. The fixture should have a minimum system efficacy of 120 lumen/Watt, ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK )=07. The fixture driver should have an operating voltage range of 140-270 V, surge protection of )=10KV, PF )0.9, THD (10%. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. (Make-Phillips / Havells / Wipro / Bajaj). |
| 445 | Supply, installation, testing and commissioning of 12 W COB downlighter Recess mounted complete with pressure die-cast aluminium housing, LEDs and electronic driver with THD (10% Output Short Circuit Protection, Surge Voltage Protection. Minimum system efficacy of 100 lumen/Watt Total Lumen shoud be 1200lumen, Operating voltage range 140 V-270 V and beam angle 60°. The fixture shall be designed for a average LED life L70B50 50000 hours. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. ( Make-Phillips / Havells / Wipro / Bajaj). |
| 446 | Supply, installation, testing and commissioning of 42 w 2 ft X 2 ft (nominal size) recessed mounted LED Panel Light, in CRCA powder coated white, suitable for recessed mounting, Armstrong/grid/POP/GB ceiling complete with Toatl system lumen )5100 lumenTHD (20%, PF )0.95. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. complete with all accessories, electronic driver, diffuser, directly on ceiling/ wall, including connections and earthing etc. as required.( Make-Phillips / Havells / Wipro / Bajaj) |
| 447 | Supply, Installation, Testing and Commissioning of 40 watt decorative LED (Housing LED) to be mounted on decorative pole complete in all respect upto entiresaticfation of engineer in Charge. ( CAT no. Twinkle PT - 230- HY). |
| 448 | Supply and Erection of 5 mtr. Decorative pole complete in all respect upto entire satisfaction of engineer in Charge. ( Twinkle Luxmax SP-114-502-Z4). |
| 449 | Supply and Erectrion of Bracket on Existing Decorative Pole complete in all respect uptoentire satisfaction of engineer in Charge. ( Twinkle Luxmax BKT - 46 single). |
| 450 | Supply, Installation, Testing and Commissioning of Size/Dimension 9U rack Height 600mm Width x 600 mm Depth, Color RAL 7035 Light Grey Usable Width 482.6mm (19 Inch),Usable Depth 200mm (07.87 in) Overall width 575mm Overall Depth 300 mm ,Overall Height 500mm (19.68 Inch),Height in 9U,Product Part No. RSOD009-001,Usable Height 400 mm (15.75 Inch). |
| 451 | Supply and laying ofhardenerat top surface 5 kg/sqm of trimix M-30 to finish surface complete in all respect.(Rate Derived from HSR B0400) 30.07.2024 |
| 452 | Supply, Installation, Testing and Commissioning of UL/FM Certified Extinguishing agent filled in PESO Approved Filling Station: 2 Kg FK-5-1-12 Clean agent filled in PESO approved stored pressure type seamless steel cylinder as per IS 7285 (life 15years) with automatic type DLP valve assembly PI marked, TPED (Transportable Pressure Equipment Directive) approved, Used Standards for type approvals ISO 17871:2015 in conjunction with EN ISO 10297:2014 EN ISO 14246: 2017-12, Push in connector, End of line adapter, UL listed Pr. Switch, end of line plug, T connector, Safety Burst Disc at 28 Bar and Mounting Bracket. Stored Pressure type fitted with Pressure gauge, UV Resistance, Operating Pressure 15 bar, Hydraulic Pressure Tested to 250 bar, Burst Pressure at 350 bar, Red Powder coated. Certified by National Test House, Dept of Consumer Affairs, Govt. of India. system design as per NFPA 2001 and Installed as per LPS 1666 |
| 453 | Supply, Installation, Testing and Commissioning of Master Control Unit inbuilt A/v alarm Control Panel along with sounder cum strobe of 24VDC operated red colour MS housing , 2 NO/NC potential free relay contact for Main Fire Alarm. Modbus for BMS Integration. Gas discharge led indicator, battery led indicator, system status Led indicator, AC power ON Led indicator. |
| 454 | Supply, Installation, Testing and Commissioning of UL Certified Linear pneumatic Heat Detection Tube (ID-6mm and OD-8mm) for automatic fire detection and suppression system made by special modified polyimide (PA), colour red RAL300, burst temperature 1310C, inner diameter 6mm, outer diameter 8mm. Pressurized with dry nitrogen at 15 bar pressure with all necessary fittings and supports. Certified by National Test House, Dept of Consumer Affairs, Govt. of India. |
| 455 | Supplying, Installing, Testing and Commissioning of Axial flow fan complete and inclusive of motor, supporting frame, G.I. Welded wiremesh inlet guard and including back draft dampers at outlet etc. as per drawings and specifications.Note :a) All motor shall be EFF-2 and H-Class,b) Fan outlet Velocity shall not exceed 16 m/s.c) Factory fitted Backdraft dampers and allaccessories shall be part of the Axial fan d) All the fans would be 2 hrs. Fire rated at 250oC Smoke Air Exhaust:-7540 Cubm/Hr. (3500 CFM) at 40 mm WG, 500mm dia, 2.2 kw motor Retail smoke exhaust fan (3Q) |
| 456 | Supply, Installation, testing and commissioning of Axial flow fans complete with motor, supporting frame, gravity louvres, weldmesh inlet guard etc. with necessary civil work as per drawings and specifications Fresh air:-7540 Cubm/Hr. (3500 CFM) at 40 mm WG, 500mm dia, 2.2 kw motor Retail smoke exhaust fan (3Q) |
| 457 | Lift lobbyPressurization Supply, Installation, testing and commissioning of Axial flow fans complete with motor, supporting frame, gravity louvres, weldmesh inlet guard etc. with necessary civil work as per drawings and specifications. 12920 Cubm/Hr. (7600 cfm)at 40 mm WG, 630 mm dia, 3.7 kw motor (3Q) |
| 458 | Supply, installation, testing and commissioning of main panel boards made of 2.0 mm thick steel sheet duly powder coated complete with voltmeter,ammeter, indicating lights, selector switch,incoming/ outgoing isolators, current operatedsingle phase preventor, CTS contactors, A/M Switch for remote controls operation complete as per specifications and drawings and as required.Incomer:1 No. 63 Amps MCCB TP plus NL of 25 KA breaking capacity incoming.1 No. 100 Amps aluminium bus bar duly sleeved as required.1 No. CT operated ammeter with selector switch.1 No. voltmeter with selector switch and control fuse.3 Nos. phase indicating lights with control fuse.Outgoing :4 Nos. 40 Amps MCCB of 15 KA breaking capacity outgoing 4 Nos. DOL Starter for 3.7 KW motor Axial fan12920 CMH for Lift lobby Pressurization 1 No. 40 Amps of spare.All Starters shall have following accessories,Overload relays,Ammeter with selector switch and CTs,Single phase preventer of MPRD-2 type,ON/OFF indicating lights,ON/OFF push buttons (3Q) |
| 459 | Supply, Installation, Testing and Commissioning of Integrated master controllers 6 and 8 channelDigital Voice Evacuation which is expandable by slave controller, capable to supervise all the speaker circuits, with required number of zone control as given below and accessories required to complete the system.Failure of Fire Panel CPU shall not result in failure of DVC operation.DVC shall be with in built with fireman microphone , PA Zone control and Remote Paging mic unit. built-in EVAC and alert voice message by SD card,auto changeover into standby when fault, with extension amplifier connector, AC mains and DC battery operation.6 Zone EVAC Controller, built-in 500W class-D amplifier, built-in EVAC and alert voice message by SD card, with fireman microphone, with AB speaker line low impedance supervision, with amplifier auto changeover into standby when fault, with extension amplifier connector, AC and DC battery operation. (3Q) |
| 460 | Supply, Installation, Testing and Commissioning of Integrated master controllers 6 and 8 channelDigital Voice Evacuation which is expandable by slave controller, capable to supervise all the speaker circuits, with required number of zone control as given below and accessories required to complete the system.Failure of Fire Panel CPU shall not result in failure of DVC operation.DVC shall be with in built with fireman microphone , PA Zone control and Remote Paging mic unit. built-in EVAC and alert voice message by SD card,auto changeover into standby when fault, with extension amplifier connector, AC mains and DC battery operation.6 Zone Router, built-in 500W class-D amplifier, with 8 zone speaker outputs and volume control, receive sources and fire alarm message from master controller, with AB speaker line low impedance supervision, with amplifier auto changeover into standby when fault, with extension amplifier connector, AC and DC battery operation. (3Q) |
| 461 | Supply, Installation, Testing and Commissioning of Booster Amplifier capable of delivering 240/480/1000 Wattage RMS power output for speakers, built-in fan for temperature control, built in line matching transformer distortion typically ( 3% @1 KHz, S/N) 80 dB complete as required, Inbuilt Line Converter, 70v and 100v output. 240 W (3Q) |
| 462 | Supply, Installation, Testing and Commissioning of Booster Amplifier capable of delivering 240/480/1000 Wattage RMS power output for speakers, built-in fan for temperature control, built in line matching transformer distortion typically ( 3% @1 KHz, S/N) 80 dB complete as required, Inbuilt Line Converter, 70v and 100v output.480W (3Q) |
| 463 | Supply, Installation, Testing and Commissioning of Remote Paging Unit with annunciator with zone controls and all zone controlmicrophone with accessories as required.12 Zones Control (Remote Paging Microphone, 12 zone capacity with 12 keypad buttons, each system can connection up to 32 remote microphone, DC24V power supply.) (3Q) |
| 464 | Supply, Installation, Testing and Commissioning of Remote Paging Unit with annunciator with zone controls and all zone controlmicrophone with accessories as required .Zone Extension Key Pad to RM-EVAC-12Z paging microphone, 12 Zone capacity, up to 11 nos keypad can be connected to EVAC-RM microphone.(3Q) |
| 465 | Supply, Installation, Testing and Commissioning of 6` 6W Ceiling Speaker with SPL at rated power/1W 90dB (1m and 1kHz). Frequency response of 125Hz – 16kHz (-10 dB with reference to 1kHz). The speaker should have tapping`s at 6W/3W/1.5W.` (3Q) |
| 466 | Supply, Installation, Testing and Commissioning of 15W Wall mount with 96dB . Frequency response of 110 Hz ~13K Hz. The speaker shoud have tappings at 15W/7.5W/3.75W (3Q) |
| 467 | Supply, Installation, testing and commissioning of cubical type dust and vermin proof H.T. Metering panel free for standing floor mounting suitable for 11 KV 3 Phase supply made out of14 gauge MS sheet with channel from base frame painted with staving synthetic light gray enameled paint suitable for operation on 11 KV 3 Phase four wire 50 cycle systems effectively earthed system and consisting of the followings:- i) 3nos 11 KV C.T of required capacity with burden class 0.5 S of approved make by HVPN. ii) ONE No PT 11KV/110 volts 3 phase oil cooled 10 VA class 0.5 of make as approved make by HVPNL .iii) 2 NOS cable holes for incoming and outgoing 11KV cable. iv)Wiring and terminal block v) THE panel will be complete with all internal wiring, inter connection of VT and HT, compound filling of cable and boxes, HT cable connections etc. complete in all respect as approved by UHBVN/DHBVN authorities including the cost of security for H.T. Meter, testing fee of CTs, PT another equipment`s as required by UHBVN/DHBVN authorities. |
| 468 | Supply, Installation, Testing and Commissioning of 10 KVA sine wave online UPS 3 Phase input and Single phase output with 16 x 42Ah 12V Exide batteries, minimum 1 hour power backup and VAH 16385 Voltage Range -320V to 460V AC 3 Phase, Output 230V AC, frequency 50Hz. Warranty as per OEM standards complete in all respect with allied cables and necessary connection upto the entire satisfaction of Engineer In Charge. |
| 469 | Providing and fixing suspended false ceiling with glass fiber reinforced acoustic gypsum baord of Size 1200X2500X12.5mm with round random perforation G8/15/20 with 9.9% perforation and NRC upto 0.55 .Installation includes providing and fixing GI perimeter channels of size 0.55 mm. Thk. having one flange of 20 mm and another flange of 30 mm and web of 27 mm along the perimeter of the ceiling, screw fixed to brick wall/ partition with help of nylon sleeves and screws, at 610 mm centers. The suspended GI intermediate channels of size 45 mm,0.9mm thk with two flanges of 15 mm each from the soffit at 900 mm centers with ceiling angle of width 25mm x 10mm x 0.55mm thk fixed to soffit with GI cleat and steel expansion fasteners. Ceiling section of 0.55 mm thk having web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are fixed to the intermediate channels with help of connecting clips and in direction perpendicular to the intermediate channel with centers of 333 mm perforated gypboardis then screw fixed to ceiling section with 25 mm dry wall screws at 300 mmcenters to G.I. framing in perfect level. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally the boards are to be joined and finished so as to have a flush lookwith uniflot. Product comes with Cleaneo Technology - Air purification and Air quality.Active reduction of air polluants thanks to Cleaneo Technology effectively reduces concentrations of VOC’s like alcohol, aldehydes, ketons and esters as well as unpleasant odours from e.g. food or cigarette smoke Air purification properties tested according to CEN standards and VDI guidelines by Fraunhof Insistute for Building Physics The false ceiling surfaces shall be preparedto the satisfaction of theArchitect, and shall be appliedwith two coats of primer and Paint to the satisfaction of Architects. (Make Armstong, Gridsquare, Anakon, Anuton) |
| 470 | Providing and fixing heavy Duty S.S Handle bolt (8` long) with nuts and screws etc complete (Grade 304) |
| 471 | Providing and fixing heavy Duty S.S tower bolt (18` long) with nuts and screws etc complete (Grade 304) |
| 472 | Providing and fixing Heavy Duty. S.S tower bolt (6` long) with nuts and screws etc complete (Grade 304) |
| 473 | Providing and fixing Heavy Duty S.S Sliding bolt (300mm x16 mm dia.) with nuts and screws etc complete (Grade 304) |
| 474 | Providing and fixing Heavy Duty S.S Sliding bolt (200mm x 16 mm dia) with nuts and screws etc complete (Grade 304) |
| 475 | Providing and fixing of 150 mm floor stainless steel door stoppers, godrej make with rubber cushion screws etc to suit shutter thickness complete. |
| 476 | Providing and fixing tiled false ceiling of specified materials of size 600 x 600 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm center to center to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-chargeProviding and fixing Knauf Danoline Perforated glass fiber reinforced Gypsum tile Belegravia MICRO with Square perforation of size 3×3 mm with c/c 8.33 mm spacing and size of 12.5mm* 600*600 mm. The reverse of the board incorporates an acoustic fleece which provides sound absorption performance( NRC value 0.60) . Front surface is White acrylic paint, RAL 9003, gloss 5. Product comes with Cleaned Technology -Active reduction of air pollutants due to Cleaned Technology, effectively reduces concentrations of VOC’s like alcohol, aldehydes, ketones and esters as well as unpleasant odors from e.g. food or cigarette smoke Air purification properties tested according to CEN standards and VDI guidelines by Fraunhofer Institute for Building Physics The false ceiling surfaces shall be preparedto the satisfaction of theArchitect (Make Armstong, Gridsquare, Anakon, Anuton) |
| 477 | Supply and Installation of Fire Resistance Door Size 2000X2400 mm, 46 mm thick Tata steel door shutter of 120 minute fire rated confirming to BS-476, Part 20-22 and lS:3614 part-II, Prototype certified from Govt. approved Lab. GQMC / CBRI Roorkee. fabricated with 2 nos of 0.8 mm thick galvanized steel sheet sandwiching fire insulation materials in between suitable for 120 minute. Door frame are manufactured with 1.2 mm thick galvanized Tata steel sheet pressed to form single rebate profile of size 100X58mm and fixing with dash fastener of approved size including Ball bearing butt hinge of size 1OOX75X3mm with screws in SSS 304 grade, Door Closer, 5mm thick Saint Gobin Fire Rated Vision Panel (Size 200X300 mm), Triple Point Panic Bar, Panic Trim, Fasteners etc. The frame and shutter are finished with powder coated approved shade, including all contingent work there to, complete in all respect upto entire satisfaction of Engineer-in-charge. (Make Navair, Ziplex, Becker Fire Solutions) |
| 478 | Supply and Installation of Fire Resistance Door Size 1200X2400 mm, 46 mm thick Tata steel door shutter of 120 minute fire rated confirming to BS-476, Part 20-22 and lS:3614 part-II, Prototype certified from Govt. approved Lab. GQMC / CBRI Roorkee. fabricated with 2 nos of 0.8 mm thick galvanized steel sheet sandwiching fire insulation materials in between suitable for 120 minute. Door frame are manufactured with 1.2 mm thick galvanized Tata steel sheet pressed to form single rebate profile of size 100X58mm and fixing with dash fastener of approved size including Ball bearing butt hinge of size 1OOX75X3mm with screws in SSS 304 grade, Door Closer, 5mm thick Saint Gobin Fire Rated Vision Panel (Size 200X300 mm), Triple Point Panic Bar, Panic Trim, Fasteners etc. The frame and shutter are finished with powder coated approved shade, including all contingent work there to, complete in all respect upto entire satisfaction of Engineer-in-charge.(Make Navair, Ziplex, Backer fire Solutions) |
| 479 | Providing and Fixing Channeled Woodworks perforated panels of width 128/192mm, thickness of 15mm and length 2400 mm or as required by the Engineer- in-Charge, made of Moisture Resistant fiber board with minimum 595 Kg/M3 density substrate with a laminated facing as per the approved shade and finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a Helmholtz fluted perforation of 3mm width and 21mm of visible panel each. The edges of the panels shall be tongue- and-grooved to receive special clips for installation. The back of the perforated panel shall have sound absorbing non- woven acoustical fleece having NRC value not less than 0.7. The panels shall be mounted on special aluminum splines using clips.The panels shall be mounted on special splines of GI steel fixed at the spacing of 600mm centre to centre and made of aluminium extruded channel size of 15mmx25mmx20mm with the help of clips required size and shape as per manufacturers specification.The thermal insulation shall be provided with Resin Bonded Rockwool confirming to IS 8183 having density of 48kg/m3 x 50mm, wrapped in virgin polythene bags fixed to the wall. Place the inside clip on the groove end of the panel along the Al keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into the groove of the earlierinserted panel and progressively installing inside clips into the next keel till the actual height is achieved. All complete with necessary synth / glass wool and framework as per manufacturer specification. (GRIDSQUARE/ARMSTRONG/ANUTONE/Anakon) |
| 480 | Providing and supplying Acoustical Wall Paneling with square edges made of rockwool tissue substrate 50mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class BS-476, as per part 4, 20, fabric with an option of colors – Ivory, Autumn Orange, Pista Green, Straw Gold, Rustic Green, Burgundy, Rust, Peacock Blue, Ash Grey, Mocha as per the choice of the Architect of size 600X600 mm providing a minimum sound absorption level of 0.80 NRC to be affixed to wall using Wall panel impalers construction adhesives as per the instructions laid down by the manufacturer. INSTALLATION: 4nos. l panel Impalers of shall be fixed to the wall surface using self tapping screws. Silica based construction adhesive to be dabbed on to the projecting elements (spikes) of the impalers. Wall panels shall be pierced through the spikes of the impalers ensuring the line and level of the panels are aintained(.GRIDSQUARE/ARMSTRONG/ANUTONE) |
| 481 | Supply and fixing of 50/85 mm continuous line puf roof panel having 0.5mm PPGI sheet outer side and 0.4 mm PPGI sheet inner side of 120gsm, 240MPA on both side,puf infill density 40 plus -2 kg/m3.RAL 9002(trapezoidal outer and inner micro ribbed panel) fix with self teaping screws with bitumen warsher and filling silicon complete all respect. (Make Anakon, Jindal, Everest) |
| 482 | Providing and fixing of PPGI Flusing (Make Anakon, jindal, Everest) |
| 483 | Supply and erection of GRC screens( jali) 50 mm thick in approved designs and sizes factory manufactureed containing alkali resistant Glass Fiber of make NEG, Japan and fixing by Dry Cladding using SS Cleats, SS Threading rods , Self Tapping Screws and Fischer make pure epoxy chemical fastner (Em Plus with RGM/ GM 8.8 grade rods ) as per design, complete including scaffolding and all other plants and machinery with all type of labour . ( Unicrete , Unistone,Rajesh GRC) with entire satisfaction of Engineer in charge. (MS structure paid seperately) |
| 484 | Supply of Door handle size 32mmx457mm H-type (CTC 308mm) to required colour or shade, with necessary SS screws and Nut etc. complete :- (make:- OZONE, Dorma, Hettics ) |
| 485 | Supply of Patch Lock to required colour or shade, with necessary SS screws and Nut etc. complete :- (make:- OZONE, Dorma, Hettics) |
| 486 | Supply and Installation of Fire Resistance Door Size 1500X2400 mm, 46 mm thick Tata steel door shutter of 120 minute fire rated confirming to BS-476, Part 20-22 and lS:3614 part-II, Prototype certified from Govt. approved Lab. GQMC / CBRI Roorkee. fabricated with 2 nos of 0.8 mm thick galvanized steel sheet sandwiching fire insulation materials in between suitable for 120 minute. Door frame are manufactured with 1.2 mm thick galvanized Tata steel sheet pressed to form single rebate profile of size 100X58mm and fixing with dash fastener of approved size including Ball bearing butt hinge of size 1OOX75X3mm with screws in SSS 304 grade, Door Closer, 5mm thick Saint Gobin Fire Rated Vision Panel (Size 200X300 mm), Triple Point Panic Bar, Panic Trim, Fasteners etc. The frame and shutter are finished with powder coated approved shade, including all contingent work there to, complete in all respect upto entire satisfaction of Engineer-in-charge. (Make Navair, Ziplex Backer Fire Solutions) |
| 487 | Providing and Filling Construction and Longitudinal joints (6 mm wide x 65 mm deep) in VDC/PQC M30 by groove cutting machine, providing and filling joints with Polysulphide Pour Grade sealent of approved make in the VDC M-30 complete as per specifications and directions of Engineer-incharge. (Item of dowel bars / tie bars to be paid separately). Derived from HSR |
| 488 | Providing and fixing for SWR Pipes (80 mm to 150 mm) specials tees, bends, couplers, single y, cross tee, short bend etc. conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge Plain Y Junctions 110MM (Supreme, Finolex, Prince) |
| 489 | Providing and fixing for SWR Pipes (80 mm to 150 mm) specials tees, bends, couplers, single y, cross tee, short bend etc. conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge Double Y Junctions 110MMx110mmx110mmx110mm (make Supreme, finolex and Prince) |
| 490 | Providing and fixing for SWR Pipes (80 mm to 150 mm) specials tees, bends, couplers, single y, cross tee, short bend etc. conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge Plain Y Junctions 160MM (Supreme, Finolex, Prince) |
| 491 | Providing and fixing for SWR Pipes (80 mm to 150 mm) specials tees, bends, couplers, single y, cross tee, short bend etc. conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge Double Y Junctions 160MMx160mmx160mmx160mm (Supreme, Finolex, Prince) |
| 492 | VANITY 1300 (W) X 600 (D) X 900 (H) VANITY: STRUCTURE MADE OF 18MM THICK IN HDMR plus PRE-LAMINATED BOARD AND FRONT MADE OF 25MM THICK HDMR plus PRE-LAMINATED BOARD WITH 2MM THICK PVC EDGEBANDED FINISH LAMINATE AS PER DESIGN and SHADE.VANITY SIZE 1300W X 600D X 900mm (H) (Jaquar, Kohlar and Hindware) |
| 493 | `S/E of ACSR conductor confirming to ISS 398/1976/ part-II with latest amendment duly ISI marked with all labour, material required to complete the job on the existing pole. (2) Size 80 Sqmm (insulated)` |
| 494 | SITC of 24 Watts Ceiling Loudspeaker, Maximum power 36 W,Soundpressure level at 24 W / 1 W (1 kHz, 1 m) -106 dB / 92 dB (SPL),Soundpressure level at 24 W / 1 W (4 kHz, 1 m) - 107 dB / 93 dB (SPL),Effectivefrequency range (-10 dB) -60 Hz to 18 kHz,Opening angle at 1 kHz/4 kHz (-6B)-160° / 60°,Rated voltage -100 V,Rated impedance 417 ohm. |
| 495 | SITC of 240 Watts Amplifier ,Inbuilt Bluetooth for audio streaming ,Supports audio playback from USB pen drive ,4 microphone/line inputs, plusmusic source input , Insert feature to use as a pre/power amplifier , Optional 2tone chime generation for input 1 , Frequency response - 80 Hz to 18 kHz (plus 1/ 3 dB @ 10 dB ref. rated output , Distortion -(1 % @ rated outputpower, 1 kHz, Sensitivity - 200 mV to 300 mV, Impedance -22 kohm. |
| 496 | SITC of Interactive Display 98 inch Display Size : 98 inch, Display,Resolution : 3840(H) ×2160 (V), Aspect Ratio : 16:9, Display Color : 1.06Billoncolors, Brightness : =450 cd/m², Response Time(ms) : 6-8ms, Glass Thickness :4mm, Touch Surface : Anti - Glare and Anti scratch, Contrast ratio : 1200:1,Dynamic Contrast Ratio : 30000:1 with OPS • i5 Processor • 8GB RAM • 256 GBSSD. |
| 497 | SITC of Full HD PTZ Camera supporting 1080p at 60 Frames perSecond, minimum 12X Optical Zoom with FoV of 72 degree and minimum 255presets. Camera should support simultaneous outputs through IP, HDMI, USB3.0 and 3G-SDI, Audio In and can be controlled via RS232/422 and IP. Panningangle -170° ~ plus 170° , Tilting angle -30° ~ plus 90. Camera should supportSRT, PoE and should be compatible with Virtual USB Driver. OEM should be BIS,CE,RoHS and FCC Certified. |
| 498 | SITC of Multiviewer with streaming solution for Video Conferencingwith 4 x HDMI inputs and 1 x HDMI and 1 x USB 3.0 outputs supporting 18Gbps(600MHz) 4K UHD support, Seamless switching with no loss of sync to displaywhen switching sources in 4x2 matrix mode, supports to store a multi-windowarrangement as a preset, EDID management, Supports easy adjustment ofwindow size, position and settings in the PiP windowing mode via the WebGUIand controllable via front panel buttons, WebGUI, Telnet, RS-232. Ability toautomatically scales 4K sources to 1080p for USB capture with video timingstabilization to help ensure a reliable and stable USB capture stream, shouldsupport capturing 2 channel digital audio from either HDMI (LPCM 2.0) or the3.5mm analog audio input (selectable via capture software). Compliance withthe UAC (USB Audio Class) and UVC (USB Video Class) standards to supportmost common capture and video streaming. |
| 499 | Supply installation testing commissioning of 450mm Gooseneckmicrophone with a programmable microphone button (Toggle on/ off, PTM,PTT, and permanent on) and a bi-color LED ring for status indication. 450mmlength, condenser capsule with cardioid pickup pattern, Frequency response: 50Hz - 20 kHz, Maximum sound pressure level: 130 dB SPL, Connectivity: XLR 3M.It should have TTL-logic output for camera control feature. |
| 500 | SITC of 43 Inch , Screen Resolution - 3840 x 2160, Brightness400cd/m2, Inbuilt Memory 16 GB, 2GB DDR3 2133Mhz RAM, Android OSVersion11, Built in Google Play store, Screen Mirroring for Android and Windowsdevices, preinstalled APPs: YouTube, Netflix, etc. HDMI x 3, USB x 2, RJ45 x 1,AV IN x 1, SPDIF Out - Yes Optical, Headphone out, Viewing Angle 178/178degree, Sound Surround Mode - Yes, Speaker output - 2 x 10W, Rated PowerConsumption 95W, Standby Power Consumption 0.5W, Power Supply AC 110V –240V,Capability to run Digital Signage Software of Same OEM, Built in Chromecast,24x7 |
| 501 | SITC of Wireless Content Presentation, Collaboration, andConferencing Solution, Wireless content sharing and collaboration applications,Optimized for video conferencing using room peripherals, Local video streamingoutput to large displays, Direct run of 3rd party web applications, Wirelesssharing from Miracast™ and AirPlay™, Powerful security features, Switchedenabled wired input, Centralized cloud management and control, PORTS -1Ethernet: On an RJ–45 connector, 2 USB 3.0: On a female USB type–Aconnector, 1 USB 2.0: On a female USB type–A connector, 2 Pin connector:Video Switching control |
| 502 | SITC of 2 Core Power cable 1.5 sqmm. |
| 503 | SITC of Mic Cable |
| 504 | SITC of 15 Mtr HDMI cable Connectors at both ends |
| 505 | SITC of 20 Mtr HDMI cable Connectors at both ends |
| 506 | SITC of 24 port Gigabit switch. |
| 507 | SITC of WIFI Access point. |
| 508 | SITC of 15U Equipment Rack with provision for housing all controlequipment with front and rear door, Blower for cooling and proper lockingarrangements |
| 509 | SITC of Intel Core i5 PC of higher, 8 GB RAM, 500GB SSD andWindow 11, Warranty 1 Year |
| 510 | Chairman Unit for Priority button, Optional chime tonefacility preceding chairman announcements. Microphone with flexible stem andlight ring. Two headphone sockets.Interconnections * 1 x 2.7 m (106.3 in) cableterminated with a 8-pin male connector for loop-through connection to other.* 1 x 8-pin circular female connector for loop-through connection to other delegateor chairman units.* 2 x 3.5 mm (0.14 in) stereo headphone sockets. |
| 511 | -SITC of Delegate Unit, Built-in volume control for headphones,Microphone with flexible stem and light ring , Two headphone socketsInterconnections* 1 x 2.7 m (106.3 in) cable terminated with a 8-pinmale connector for loop-through connection to other. * 1 x 8-pin circular femaleconnector for loop-through connection to other delegate or chairman units. * 2x 3.5 mm (0.14 in) stereo headphone sockets. |
| 512 | SITC of Control Unit , Controls up to 50 Discussion units , 3-Bandequaliser for better sound performance, Audio interfaces for connecting externalaudio equipments ,Mains voltage - 230VAC,50 Hz (±10%), DC voltage supplyto contribution units -24V ± 1V DC,THD at rated output - (1%, Mic inputsensitivity - 1 mV ( plus 1/-3dB),sensitivity-100mV ( plus 1/-3dB),Frequencyresponse - 200 Hz to 12 kHz, Input Impedance - 4.7 kohm |
| 513 | SITC of Extension cable assembly 10M |
| 514 | SITC of Premium-sound cabinet loudspeaker ,Maximum power - 45 W, Rated power - 30 W (30 / 15 / 7.5 / 3.75 W), Sound pressure level at rated /1 W (1 kHz, 1 m) -105 / 90 dB (SPL), Effective frequency range (-10 dB) - 100Hz to 18.5 kHz, Opening angle 1 kHz / 4 kHz (-6 dB) - 160° / 81° (horizontal) /150° / 90° (vertical), Rated input voltage - 15.5/70/100 V, Rated impedance -8 /163 / 333 ohm |
| 515 | SITC of 120 Watts Amplifier ,Inbuilt Bluetooth for audio streaming ,Supports audio playback from USB pen drive ,4 microphone/line inputs, plusmusic source input , Insert feature to use as a pre/power amplifier , Optional 2tone chime generation for input 1 , Frequency response - 80 Hz to 18 kHz (plus 1/ 3 dB @ 10 dB ref. rated output , Distortion -(1 % @ rated outputpower, 1 kHz, Sensitivity - 200 mV to 300 mV, Impedance -22 kohm |
| 516 | SITC of 1.5 mtr HDMI cable in existing pipe/ channel connectors atboth ends complete in all respect. |
| 517 | -SITC of 18U Equipment Rack with provision for housing all controlequipment with front and rear door, Blower for cooling and proper lockingarrangements and as per the specifications, complete in all respect upto theentire satisfaction of Engineer - in - Charge of the work. |
| 518 | Supply, Installation, Testing and Commissioning of High PowerThree-Way Bi-amp / Tri-amp Switchable Loudspeaker with 1 x 15” LF andRotatable Horn: Coverage Pattern should be 60° x 40° or better with rotatablewaveguide: Should have Frequency Range 39Hz–20kHz orbetter: Should havePEAK Maximum SPL (LF) 133dB - 136dB or better, (MF/HF) 139dB - 142dB orbetter: Sensitivity (LF) 97dB - 100dB or better: Sensitivity (MF/HF) 108dB -111dB or better: Should have PEAK Long Term 100hrs Power rating (LF) 2400W- 2600W orbetter: Should have PEAK Long Term 100hrs Power rating (MF/HF)800W - 1000W orbetter: Impedance 8 Ohms / 10 Ohms: Should support Bi-ampmode and Tri-amp mode switchable : Should have 15 ormore M10 points forsuspension: etc. |
| 519 | Supply, Installation, Testing and Commissioning of Flying, dual 15`LF or more subwoofer: Frequency Range 32 Hz – 1 kHz (-10 dB): FrequencyResponse 38 Hz – 1 kHz ( ± 3 dB): System Sensitivity (dB-SPL, 1W @ 1m)-100dB: Maximum SPL 132dB - 135dB or more: Long-Term System Power Rating:1350 W - 1450W: etc |
| 520 | Supply, Installation, Testing and Commissioning of M10, Eye-Bolt Kitfor above Loudspeakers and Subwoofer Unit: etc. A |
| 521 | Supply, Installation, Testing and Commissioning of High Power TwoWay Loudspeaker with 1 x 15” LF and Rotatable Horn: Coverage Pattern shouldbe 120° x 60° ormore with rotatable waveguide: Frequency Range 35Hz–20kHzorbetter: Should have PEAK Maximum SPL 130dB - 133dB orbetter: PassiveCrossover Frequency: 1.4kHz: Sensitivity Should be 96dB - 99dB or better:Should have PEAK Power rating 2400W - 2600W or better: Impedance 8 Ohms:Should support Bi-amp mode and Passive mode switchable: Should have 15ormore M10 points for suspension: etc |
| 522 | Supply, Installation, Testing and Commissioning of M10, Eye-Bolt Kitfor above Loudspeakers Unit: etc. |
| 523 | Supply, Installation, Testing and Commissioning of 12` Two-WaySelf-Powered Stage Monitor Loudspeaker System: should support Power rating2000W(pk) ormore: Frequency Range 51Hz – 20kHz orbetter: Max. SPL 132dBor more: Coverage Pattern 90° x 50° or better: Crossover Frequency: 2050Hz:User selectable Optimized presets for Main or Monitor position: 100V - 240V ~50/60 Hz Operation: Should support audio connectivity with minium 2 x XLRbalanced Combo jacks: 1 x 3.5mm aux input: 2 x XLR-M loop-through: 1 x XLRM mix out: etc |
| 524 | -Supply, Installation, Testing and Commissioning of AdvancedFeedback Suppression: should support Stereo or Dual Independent ChannelProcessing: Inputs / Outputs 2In / 2 Out: Max input line level plus 20dBu ormore: A/D Conversion 24bit orbetter: THD plus Noise 0.003% or better: Shouldhave Wizard Setup Function: Should have Full LCD Display: 24 or moreProgrammable Filters per Channel: Live and Fixed Filter Modes: 24 or more LEDper Channel Filter Metering: Input Impedance: Balanced 50kO, Unbalanced25kO: Frequency Response: 20Hz – 20kHz, plus /- 0.5dB orbetter: Crosstalkinput to output )80dB ormore: etc. |
| 525 | -Supply, Installation, Testing and Commissioning of Compact Two -way Loudspeaker with 2 x 8”-10` orbetter LF Driver: PEAK Power rating 1500W- 1800W ormore: Impedance 8 Ohms: Coverage Pattern 120° x 60° or better:Frequency Range 54Hz-20kHz or more, Frequency Response 65Hz-20kHzormore: Should have Max SPL 120dB - 123dB or above: System Sensitivity 94dB- 97dB or above: Crossover: 2.1kHz: etc. |
| 526 | Supply, Installation, Testing and Commissioning of Wall Mount U Type Bracket for above Front Fill Loudspeaker: etc |
| 527 | -Supply, Installation, Testing and Commissioning of Two Way UltraCompact Wall Mount Loudspeaker for indoor and outdoor uses with 3` - 4` LFDriver, Frequency Range 72Hz–20kHz ormore: Should have Peak Power rating160Watts - 200Watts or better: Peak Max SPL 109dB or better: Should have70/100V Transformer taps 15W, 7.5W, 3.7W ormore: 100-120 degree (H) x100-120 degree (V) orbetter coverage: etc |
| 528 | Supply, Installation, Testing and Commissioning of Wired GooseneckMicrophone with Desktop base unit for portable podium uses. It should supportCardioid or better polar pattern: built-in on/off switch: Audio frequencybandwidth 70-18000Hz ormore: Signal to Noise 64dB-A orbetter: 500mm(50cm) or more in Length: 9 to 52V Power Interface: etc. |
| 529 | -Supply, Installation, Testing and Commissioning of wired Vocalmicrophone Should be Professional Dynamic Handheld Microphone and On/OffSwitch: should support Polar Pattern supercardioid orbetter Audio Frequencybandwidth 70 to 20000Hz ormore: Sensitivity 2.6 mV/Pa or better: ElectricalImpedance : 600 Ohms or better: Recommended Load Impedance : 2000 Ohmsor more: Connector Type : 3-pin XLR Male (Balanced): Metal Body: etc |
| 530 | Supply, Installation, Testing and Commissioning of Wired DynamicInstrument Microphone with Cardioid orbetter Dynamic Instrument Microphone:Audio frequency bandwidth 50-20000Hz ormore: Sensitivity 2.5 mV/Pa or more:Max. SPL 47dB or more: etc. |
| 531 | -Supply, Installation, Testing and Commissioning of Self-PoweredTwo-Way Studio Monitor with 6.5` - 8.0` LF Driver, INPUT SENSITIVITY :(-10dBV INPUT) 92dB / 1m, Power Configuration: Bi-amplified , HF DRIVERPOWER AMP : 56W or better, Class-D , LF DRIVER POWER AMP : 56W or better,Class-D , Frequency Range (-10dB): 41Hz – 24kHz , MAXIMUM CONTINUOUSSPL: 98dB - 101dB, Maximum Peak SPL: 108dB - 111dB or better, MAXIMUMPEAK INPUT LEVEL(-: 10dBV / plus 4dBu) plus 6dBV / plus 20.3dBu: etc. |
| 532 | -Supply, Installation, Testing and Commissioning of Professionalstudio grade closed-back headphones for Main FOH Monitoring, should supportauto mute technology: Max. Input Power 200mW orbetter: Audio frequencybandwidth 16-28000Hz ormore: Sensitivity 104dB or more: Should comes with adetachable cable: etc. |
| 533 | Supply, Installation, Testing and Commissioning of MultichannelDigital Network Based Power Amplifier with 1250W - 1300W ormore per channel@ 8 Ohms power output: should have four or more inputs and outputs analogaudio channels: Should support 70Vrms and 100Vrms output on all outputchannels: THD 0.35% orbetter: Should support Cooling Continuously variablespeed forced air: Voltage Gain 34dB ormore: Digital audio bus compatibility upto 8 or more audio channel: Should have bridgeable channels even for 100Vrmsmode to operate with 200Vrms output: 2digital audio bus RJ 45 port: 1 EthernetRJ45 port for monitoring and configuration: Should have DSP features Incl.Limiters, Input/output EQ, Delay, Matrix Mixer, Speaker Line Monitoring:Damping Factor )1500 ormore: etc |
| 534 | -Supply, Installation, Testing and Commissioning of MultichannelDigital Network Based Power Amplifier with 600W - 650W or more per channel@ 8 Ohms power output: should have four or more inputs and outputs analogaudio channels: should support 70Vrms and 100Vrms output on all outputchannels: THD 0.35% orbetter: Should support Cooling Continuously variablespeed forced air: Voltage Gain 34dB ormore: Digital audio bus compatibility upto 8 or more audio channel: Should have bridgeable channels even for 100Vrmsmode to operate with 200Vrms output: 2digital audio bus RJ45 port, 1 EthernetR 45 port for monitoring and configuration: Should have DSP features incl.Limiters , Input/output EQ , Delay ,Matrix Mixer ,Speaker Line Monitoring:Damping Factor )1000 or more: etc. |
| 535 | Supply, Installation, Testing and Commissioning of Dual channelDigital Power Amplifier with per channel power output of 2100W - 2500W orbetter @ 4 Ohms / 6 Ohms : Sensitivity shoul be 1.4V, Should have bridgemode power output 6000W - 6800W or better at 4 Ohms / 6 Ohms , Signal toNoise Ratio should be 103dB - 106dB or above, Total Harmonic Distortionshould be (0.5%, Damping Factor 20 Hz to 1kHz should be 500 or above,Frequency Response (at 1W, 20 Hz to 20 kHz) plus 0 dB, -1 dB, Crosstalkshould be )70 dB or more, Input Impedance 20kO balanced, 10kO unbalanced:etc |
| 536 | Supply, Installation, Testing and Commissioning of dual channelpower amplifier with 120W - 150W ormore power output @ 8Ohms, 70V/100V:Input Sensitivity: 1.4Vrms for 8-ohms: Input Impedance 20K ohms orbetter:2xRJ45connector for external controls: etc. |
| 537 | SITC of Mic Stand |
| 538 | Supply installation testing commissioning of 55` 4KUHD resolutionLED Display with Android 11, 400 nits brightness, Cortex A55 1.3Ghz processor,Mali G31 MP2, Open GLES3.2, 2 GB DDR RAM, 16 GB Memory, Wifi Typesupport both 2.4 and 5G Standard, Dolby Audio, Built in Wifi and Cromecast,HDMI CEC, HDMI ARC, Built-in Bluetooth, Hotel mode, Meeting Mode,20W builtin speakers, HDMI 2.0 X 2, AV X 1, USB X 2, RJ45 X 1, SPDIF Out x 1,24/7operational |
| 539 | Stand for Confidence monitors. |
| 540 | upply, Installation, Testing and Commissioning of Floor BOX withPower/LAN/XLR/HDMI Connectivity and space for AVOIP encoders |
| 541 | -Supply, Installation, Testing and Commissioning of HDMI recorderwith Pass Through. 2TB storage included. With dual slots for HDD. Option ofrecording to USB-C disks. Support for h.265, h.264. |
| 542 | Supply, Installation, Testing and Commissioning of FHD1080p/60fps,1/2.8``, CMOS, Effective Pixel: 2.07 Megapixels,30x OpticalZoom,8X Digital Zoom,camera should have a standard Video Output and shouldsupport HDMI/DVI and 3G-SDI Ports so that Camera can be integrated withstandard End Points. Apart from that , It should have native USB 3.0 supportalong with HDMI/DVI support so that it can also be connected with Softwarebased VC Solution.should have 60.7 Degree or better field of view,should haveat least 250 Position Presets,supplied with IR remote control as an includedaccessory,f4.42mm ~ 132.6mm, F1.8 ~ F2.8,0.5 Lux @ (F2.0, AGC ON),shouldhave at least 250 Position Presets, Digital Noise Reduction,YUY2, H.264 / MJPEGCompression,Horizontal Rotation ±170°,Vertical Rotation -30° ~ 90°,Number ofPreset 255,USB 3.0 Type-A, HDMI, 3G-SDI, Rj45, RS232, Line In/Out,VISCA/Pelco-D/ Pelco-P,CE, ROHS and FCC. |
| 543 | -Supply, Installation, Testing and Commissioning of Keyboard andJoystick Control, VISCA protocol campatible keyboard and camera controler,Multifold communication mode - RS485, RS422, RS232, 10M internet(select toorder), USB(select to order), Control the rotation of speed dome camera andswinging angle of joystick with nonpolar variable speed control to embodyspeed dome camera’s rotating speed real-time, Transmission range - All inputand output communication port use anti-radar design, powerful anti-jammingperformance, the standard transmitting distance is 1200 meters, Key numbersMaximum sub-control keyboard:16 qty, Password - Keyboard operationpassword on/off/lock function, LCD display for user interface, Protocol - Pelco-D,Pelco-P, VISCA, Communication Range - RS485, RS422: 1200m, RS232: 10m,Cascade connection number - cascade 16 sub-control at most, controller ID:0-15, Joystick feature of 3D(control: up, down, left, right, zoom), powerconsumption of 6W. |
| 544 | Supply, Installation, Testing and Commissioning of AVOIP Networkswitch with 24 # 1G Base-T Copper PoE plus Ports, 02 # 1G Base-T CopperPorts, 04 # 1 Base-X Fiber SFP, RAM: 2 GB, Dedicated Quad-Core Cortex-A57ARMv8 1.8Ghz CPU (64-bit), Packet buffer memory: 16 Mb, Flash: 256 MB,300W PoE Budget, Switching fabric: 60 Gbps Line-Rate (non blocking fabric). |
| 545 | -Supply, Installation, Testing and Commissioning of 18Gbps 10-feetHDMI Cable |
| 546 | Supply, Installation, Testing and Commissioning of 18Gbps 6-feet HDMI Cable |
| 547 | Supply, Installation, Testing and Commissioning of 2.5 Sqmm speaker cable |
| 548 | Supply, Installation, Testing and Commissioning of 2 core shielded balanced microphone cable. |
| 549 | Supply, Installation, Testing and Commissioning of 3 core 1.5 Sqmm power cable |
| 550 | Supply, Installation, Testing and Commissioning of 6` Hight speed USB A-B 3.0 Cables |
| 551 | SITC of 8 core snake cable |
| 552 | Supply, Installation, Testing and Commissioning of 6` USB C Cable with Thunderbolt and 65W charging support |
| 553 | Supply, Installation, Testing and Commissioning of Advanced Feedback Suppression: should support Stereo or Dual Independent ChannelProcessing: Inputs / Outputs 2In / 2 Out: Max input line level plus 20dBu or more: A/D Conversion 24bit orbetter: THD plus Noise 0.003% or better: Shouldhave Wizard Setup Function: Should have Full LCD Display: 24 or more Programmable Filters per Channel: Live and Fixed Filter Modes: 24 or more LEDper Channel Filter Metering: Input Impedance: Balanced 50kO, Unbalanced 25kO: Frequency Response: 20Hz – 20kHz, plus /- 0.5dB orbetter: Crosstalkinput to output )80dB ormore: etc |
| 554 | Supply, Installation, Testing and Commissioning of Wired GooseneckMicrophone with Desktop base unit for portable podium uses. It should supportCardioid or better polar pattern: built-in on/off switch: Audio frequencybandwidth 70-18000Hz ormore: Signal to Noise 64dB-A orbetter: 500mm(50cm) or more in Length: 9 to 52V Power Interface: etc... |
| 555 | Supply, Installation, Testing and Commissioning of Wired DynamicInstrument Microphone with Cardioid orbetter Dynamic Instrument Microphone:Audio frequency bandwidth 50-20000Hz ormore: Sensitivity 2.5 mV/Pa or more:Max. SPL 47dB or more: etc... |
| 556 | SITC of MAIN CURTAIN made out of Fire Retardant velvet curtain cloth with horizontal sliding arrangement complete with fixing curved rails, brackets, sliding arrangement and motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton) 2nos. air breaker contactors (LandT / SIEMENS), 2nos. micro switches for auto stop, 3 nos push buttons for fcrward, reverse and stop pcsiticns. The curtain should be· draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering, with Main Frill. Size:9m x24 including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge |
| 557 | SITC of CENTER CURTAIN made out of Fire Retardant velvet curtain cloth with horizontal sliding arrangement complete with fixing curved rails, brackets, sliding arrangement and motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton) 2nos. air breaker contactors (LandT / SIEMENS), 2nos. micro switches for auto stop, 3 nos push buttons for fcrward, reverse and stop pcsiticns. The curtain should be· draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering, with Main Frill.including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge. Size:9 m x24 m, |
| 558 | SITC of REAR CURTAIN made out oftreated black colour crepe/galaze / cloth cotton clotr. with horizontal sliding arrangement complete with fixing curved rails, brackets, sliding arrangement and motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton) 2nos. air breaker contactors (LandT/SIEMENS), 2nos. micro switches for auto stop, 3 nos push buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge. Size:-9 X 24 MTR |
| 559 | MAIN VALANCE: SITC of High quality Velvet fabric fire retardant treated as per approved colour and make with a gathering of 100% stitched Oas per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on 25MM GI PIPE (For Main Valance) including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge. Size: 24Mtr x 1.8Mtr. |
| 560 | Supply, installation, testing and commissioning of Wall mounted type indoor unit with cordless remote controller. Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete including cordless remote with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer .Make: Toshiba/Mitsubishi Heavy/O General 2.5 TR hiwall |
| 561 | Supply, installation, testing and commissioning of Wall mounted type indoor unit with cordless remote controller. Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete including cordless remote with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer. Make: Toshiba/Mitsubishi Heavy/O General 2.0 TR hiwall |
| 562 | Supply, installation, testing and commissioning of Wall mounted type indoor unit with cordless remote controller. Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete including cordless remote with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer. Make: Toshiba/Mitsubishi Heavy/O General1.5 TR hiwall |
| 563 | Supply, fixing and commissioning of refrigerant joint / Branch distibutors between Indoors with nitrile rubber insulation, supporting etc.complete as required. Make: Toshiba/Mitsubishi Heavy/O General |
| 564 | Y Joints Supply, fixing and commissioning of refrigerant joint / Branch distibutors between Outdoors with nitrile rubber insulation, supporting etc. complete as required. Make: Toshiba/Mitsubishi Heavy/O General |
| 565 | Supply installation Testing and Commissioning of Touch Type centralised controller suitable for Controlling to connect all indoor units as complete as required. Make: Toshiba/Mitsubishi Heavy/O General |
| 566 | Drain Piping Supply Installation Testing and Commissioning of rigid UPVC piping with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation etc. complete as required.32 mm dia |
| 567 | Drain Piping Supply Installation Testing and Commissioning of rigid UPVC piping with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation etc. complete as required. 25 mm dia |
| 568 | Supply, installation and testing of acoustic lining of ducts with glass wool of 24 Kg/sqcm, the glasswool shall be covered with RP tissue paper and fixed with roofing nut and bolt complete as per specification and complete as per requirement.. Thermal conductivity of the insulation material shall not exceed 0.047 W/moK at an average temperature of 20oC. 25 mm thick acoustic lining Make: UP Twiga/ Ownes Cornin |
| 569 | Supply and Erection of 100 watt LED Flood light suitable for operation on 230V ,50Hz complete the job in all respect. |
| 570 | Supply installation and fixing of fire retardant non porous double layer flexible connection between each AHU as complete as required. (canvas connection) |
| 571 | Grilles / Diffuser Supplying and fixing of powder coated extruded aluminum Supply and Return Air Diffusers with aluminum volume control dampers as per specifications |
| 572 | Grilles / Diffuser Supplying and fixing of powder coated extruded aluminum Supply Air Grills with aluminum volume control dampers as per specifications |
| 573 | Supplying and fixing of acoustic lining of duct with Open Cell Nitrile Rubber density 140-180 Kg/m³. Applied by Adhesive, conforming to standard specification. 10 mm thick open cell nitrile rubber |
| 574 | Supply and charging of Refrigerant gas R-410 for top up as complete as required. |
| 575 | -FRILLS Providing and fixing average frills made out of double gathering glazed cotton cloth to be installed above the stage on 25mm dia GI pipe including cost ,conveyance, loading, unloading,labor ,T and P, sundries, scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge. Size:-24 m x 1.5 m, |
| 576 | -SIDE WINGS: SITC of Fixed Wing Structure designed as per site condition for a height approx 5.5Mtr x 1Mtr made up of MS Square tube of 25mm or higher size rested on pilotable trolley on a track for the rotation of the wing. Adjustable floor locking screw jacks with rubber grips including cost ,conveyance, loading, unloading, labor ,T and P, sundries, scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge. 9 MTR X 2 MTR |
| 577 | -MOTORISED LIGHTING BAR-Supply, installation, testing and commissioning of motorized lighting bar operated with 1 HP 3 phase ( kirloskar I ABBI Siemensl Cromptonl Havells ) motor, Aluminium Ole cast heavy duty gear box` 2 nos. air breaker switch ( LandT siemens) for up and down, 2 nos. microswitch for auto stop, 48 mm dia GI pipe. Pile Winding drum plates of not less than 5mm thickness and suitable dia. to wind 4mm rope for a lift of more than 5 mtr including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification anddirection of the Engineer- in-charge |
| 578 | SITC of MS suspension grid - Providing and fixing MS angle raftersabove stage area of stage at 1200x600mm centres with 2 x 40x40x5mm thickMS angle runners and 25x12x12mm thick studs as MS spacers fixed @ 600mmc/c sandwiched between the MS angle runners so as to maintain 12mm gapbetween MS Angles. The Grid so formed to be suspended from bottom of theroof structure by means of 35 x 5mm thick MS flat suspenders / fixed to the wall/ fixed to Proscenium with MS cleats and dash fasteners at 1200mm centre tothe Grid including painting. 9 mtr x 23mtr (APPROX) including cost ,conveyance,loading,unloading, labour ,T and P,sundries,scaffolding required for work etc,complete as per specification and direction of the Engineer- in-charge. |
| 579 | SIDE LADDER: SITC of STAGE SIDE LADDER : M.S. Pipe Ladders tobe provided on sides of the Stage to be fixed on the existing GI pipe or top grid.Made of 50mm x 25mm MS pipe of following 2400*600 including cost,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding requiredfor work etc, complete as per specification and direction of the Engineer- in-charge |
| 580 | SITC of 200WLED PROFILE: Power Supply: AC 100V - 240V, 50-60HZSource- COB LED,Wattage - 200W, CCT – 3200K / 5600K , CRI - =90 , Beamangle - 19°/26°/36° (Optional), R9 Value 90 plus , Tel. Lighting ConsistencyIndex 97 plus , Pan/ tilt - Manual, Controls - DMX512, Auto run, Master/SlaveDMX channels - 1/2CH (Single color), 2/5CH (2in1) : (OPTIONAL )Dimmer/strobe - 0~100% linearly adjustable/ 1-25 times/sec, Operating Voltage- 90-260V AC, IP Rating - IP20, Operating temperature - 30°C~40°C Finish -Black, Certification: CE including cost ,conveyance, loading,unloading, labour ,Tand P,sundries,scaffolding required for work etc, complete as per specificationand direction of the Engineer- in-charge |
| 581 | SITC of 200W LED FRESNEL : Power Supply: AC 100V - 240V, 50-60HZ ,Light Source- COB LED, Wattage - 200W,CCT – 3200K / 5600K , CRI -=90, Beam angle - Manual 19°-50° gives a very soft edged beam as well asspreading a great deal of light outside the beam, Pan/ tilt - Manual Controls -DMX512,mater and slave, auto running, sound mode, DMX channels - 1/2CH(Single color),2/5CH (2in1),3/7CH(3in1,4/8 CH(4in1),Color system - Single WWor CW(150W/200W/300W(2in1/4in1)180W(3IN1), Optional, Dimmer/strobe -0~100% linearly adjustable Operating Voltage - 90-260V AC,IP Rating - IP20Operating temperature - 30°C~50°C ,Finish - Black Weight - 8.5Kg,Certification: CE including cost ,conveyance, loading,unloading, labour ,T andP,sundries,scaffolding required for work etc, complete as per specification anddirection of the Engineer- in-charge |
| 582 | -SITC of 200W LED PC: Power Supply: AC 100V - 240V, 50-60HZ,Light Source- COB LED , Wattage - 200W, CCT – 3200K / 5600K , CRI - =90 ,Beam angle - Manual 15°-35°,Pan/ tilt - Manual,Controls - DMX512,mater andslave, auto running, sound mode,DMX channels - 1/2CH(Single color),2/5CH(2in1),3/7CH(3in1,4/8 CH(4in1) Color system - Single WW or CW(150W/200W/300W) 200W/300W(2in1/4in1)180W(3IN1), OptionalDimmer/strobe - 0~100% linearly adjustable Operating Voltage - 90-260V AC,IPRating - IP20 Operating temperature - 30°C~50°C,Finish - Black Weight - 8.5Kg, Certification: CE including cost ,conveyance, loading,unloading, labour ,Tand P,sundries,scaffolding required for work etc, complete as per specificationand direction of the Engineer- in-charge |
| 583 | SITC of WW/CW LED PAR : 150W LED , CCT: TW-3200K/TC-5600K, Ra) 93,voltage : ac-100-240v, 50/60Hz, Max Power 143, Power Connection :Power in and out, DMX XLR : DMX SPLITTER IN/OUT.IP 65 including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding requiredfor work etc, complete as per specification and direction of the Engineer- incharge |
| 584 | SITC of MOVING HEAD : Power voltage : AC100-240V ,50/60Hz,Power consumption : 250W,Color temprature : 8500k,Beam Angle : 0°-3.8°(by aperture},Pan/Tilt : 540°/250°,DMX channel mode : 16channels,Color Wheel : 14 colors plus white with rainbow effect,Gobo wheel : 1fixed gobo wheel with 17 gobos plus open,Prism : 8/16/24 facet prism rotatingin both directions,Focus : Motorized focus,Frost : 0-100%,Display : LCD displayPower Socket : Powercon in including cost ,conveyance, loading,unloading,labour ,T and P,sundries,scaffolding required for work etc, complete as perspecification and direction of the Engineer- in-charge |
| 585 | SITC of LED BATTEN FOR CURTAIN: Body Material Aluminum alloystructure,Product size 1000mm × 59mm × 116mm, Voltage AC100-240V50/60Hz Input Power 200W, Lamp Type 18pcs x 10W LEDs Average Life Span50,000h,Color System 18pcs RGBW 4 in 1 ,Color Temperature 2700K~8000K,Control Channel 8/72/76 control channel modes, Control Mode StandardDMX512, Master/Slave control mode, Sound Active, Auto Run Menu Display LEDdisplay, DMX Signal Connection 3-pin XLR In/Out, Beam Angle 25°,40°(Optional) Working Temperature -20-40?, including cost ,conveyance,loading,unloading, labour ,T and P,sundries,scaffolding required for work etc,complete as per specification and direction of the Engineer- in-charge |
| 586 | SITC of LED FLOOD LIGHT:LIGHT SOURCE: 70W -100W , Integrateddesign - means the case never needs to be opened Long lifetime - no bulbreplacements plus 70% light output maintenance to 30,000 hours Slimline -main body is 40mm thick. High efficiency - around 85 lumens/watt (4,300lm)More robust .TYPE: MSSP- LED 100W etc complete as required. including cost,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding requiredfor work etc, complete as per specification and direction of the Engineer- incharge |
| 587 | SITC of DMX SPLITTER: DMX Splitter with one DMX input and 8buffered outputs and 3 pin / 5 pin XLR connectors.including cost ,conveyance,loading,unloading, labour ,T and P,sundries,scaffolding required for work etc,complete as per specification and direction of the Engineer- in-charge |
| 588 | SITC of LIGHTING CONSOLE: Lighting Console with Internal FlashDrive, similar in functionality to a hard disk but faster and more rugged.Provides enough storage for:- The entire Fixture Library of more than 3,000files, New Locate Fixture button, Fixture Selects (selecting the top row offaders), 2048 Channels, 240 Intelligent Fixtures,240 Dimmer Control Channels,Theatrical Plotting and Playback functions, Shape Generator for instant creationof patterns and effects, 15 Playback Masters controlling 450 memories, chasesor cue lists, MIDI and Bass, Mid, Treble sound to light triggers, Colour VGAoutput fitted as standard, Front panel now reverse printed PolyCarbonateLaminate using technology from the Diamond 4, this is incredibly hard wearingand looks excellent, Each console individually has an electronic serial , Suppliedwith PC applications: Avolites Visualiser, Pearl Simulation program and CacheBuilder.including cost ,conveyance, loading,unloading, labour ,T andP,sundries,scaffolding required for work etc, complete as per specification anddirection of the Engineer- in-charge |
| 589 | SITC of DMX LOOP POINT WIRING WITH ALL REQUIREDCONNECTORS FROM SPLITTER TO ALL LIGHTING FIXTURES. including cost,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding requiredfor work etc, complete as per specification and direction of the Engineer- incharge |
| 590 | SITC of foot power point etc as required. including cost ,conveyance,loading,unloading, labour ,T and P,sundries,scaffolding required for work etc,complete as per specification and direction of the Engineer- in-charge |
| 591 | SITC of Suspender cum clamps designed made out of MS material150mm x 150mm x 5mm MS Base plate Threaded rod, Black powder coatedfinish All the materials under gone through 7 tank process with various chemicaltreatment to keep them rust free Suitable to hold various type grid and otherrigging systems.including cost ,conveyance, loading,unloading, labour ,T andP,sundries,scaffolding required for work etc, complete as per specification anddirection of the Engineer- in-charge |
| 592 | SITC of Light Fixture dual safety Chain made up of GI wire ropeBundled and twisted together Having load bearing capacity above 200 Kgs.including cost ,conveyance, loading,unloading, labour ,T andP,sundries,scaffolding required for work etc, complete as per specification anddirection of the Engineer- in-charge. |
| 593 | Providing and fixing of staggered 2nd layers/Mr Ply 12mm thick MR ply of approved make like century, Duron, Green ply, Merino or equivalent fixedto natural wood frame work of approved size fixed at 300 mm c/c both ways The nature wood framework to be supported cleat pads and held in position by35x35x5 mm angle cleats of 75mm length at 1200 mm centers. The wooden framework to be filled with 25mm thick thermal bonded polyester waddingmicron fiber of 1000 gm/sqm (Make: Sunshine india/ Nowofill / Vibrant or equivalent) held in position with 18mm 24 SWG chicken mesh fixed on thebottom of the wooden framework with necessary screws and washers. The cleats to be given two or more coats of zinc chromate primer. The cleat to beprewelded to the and screwed to the wooden framework with necessaryscrews.The work shall be executed as per drawings ,specifications andinstructions of engineer in charge |
| 594 | Supply and fixing Engineered Wood flooring:-The blonde hues foundin this 3-strip ash floor from the Nordic Naturals Collection range from amberhoney to vanilla cream. To create this lively effect, lighter surface wood hasbeen mixed with darker core wood.Collection-Nordic Naturals CollectionSurfacetreatment-Matt lacquerConstruction-3-layer parquetProduct measurements-200x 2423 x 15 mm Engineered Wood flooring |
| 595 | Supply, Installation, testing and commissioning of Light Point Wiring from Patch Panel to be Provided near stage to various stage light fixtures with 2.5 Sq.mm 3 Core PVC Insulated and PVC Sheathed Cable including Cable Tray of suitable size for laying these wires on the tray including 15-20 amps metallic clad sockets with box at top etc complete as required. including cost ,conveyance, loading, unloading, labour, T and P, sundries, scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge. |
| 596 | Supply, erection, testing and commissioning of 13 passengers(BplusGplus2 floors) Electrical Traction Elevator Room less , Gearless with Speed of 1.0 mtr/Second serving 4 Stops and 4 Opening with SS Vandal finish, hand rail, Mirror and Antiskid PVC Flooring to be erected in accordance with the following Technical Specification and as per latest IS Specification. i) Type and capacity: Passenger Elevator App. 884 Kg. 13 person ii) Speed mps : 1.0 mtr per second iii) Travelling (max) in mtrs : Approx. 16 mtrs iv) Serving: (B plus G plus 2) 4 stops, 4 opening- Two-panel center opening Door panels with full-glass) v) Power Supply: 415 V, 3 phase, 50 HZ A C supply. vi) Control: High Performance simplex full collective integrated serial communication control system. vii) Operation: Automatic viii) Motor: Permanent Magnet Synchronous Electric Traction Gearless Motor to be hoisted on guide rail within the elevator hoist way ix) Location of Motor: Motor to be hoisted above the rail within the elevator hoist way. x) Type of Drive: A. C. Variable Voltage Variable frequency with 16 Bit Microprocessor xi) Car inside area : 1600 mm Wide x 1400 mm Deep (2.24 Sq. meter xii) Car Enclosure : S.S Scratch Resistant Cabin, Granite flooring on heavy duty M.S. Platform, Decorative False Ceiling With CFL/LED Lighting, Blower/Rotor motor xiii) False Ceiling : Stainless steel false ceiling in hair line finish xiv) Car Panel : stainless steel (scratch free) Hair line finish xv) Flooring : B,G ,1,2 xvi) Clear Opening of door : 900 mm wide x 2000 mm Height xvii) Door Operation : Automatic DC/AC with adjustable Door Opening and closing timings with center opening sliding door xviii) Car Door: Center opening automatic door Two-panel center opening Door panels with full-glass. Landing door : Center opening automatic door Other Features: i) Battery operated intercom, emergency alarm and emergency light with maintenance free rechargeable battery. ii) Adjustable guide shoes. (Ensures good ride comfort) iii) Digital direction and position indicator in Car and at all landings. iv) Integral full height car opening panel with luminous combined with direction arrows, overload warning indicator and services cabinet v) Hands free press and speak intercom with EPABX for three way communication. vi) a) Automatic rescue device with batteries etc. to rescue the Passenger in case of emergency the device will bring the elevators to the nearest floor and open the door automatically in Case of power / phase failure / low voltage. b) Manual Rescue lever` vii) Full height infrared safety curtain (Highly sensitive safety device for safe entrance and exit of the Passenger into the Car and automatic floor announcer. viii) Diffused lighting in car. ix) Cross flow fans=2 Nos. x) Looking mirror in side of lift car. xi) Face plate Finish: stainless steel in hair line. xii) Face plate: Rectangular. xiii) A three feet high railing shall be provided on car top xiv) The motor shall be high starting torque and low starting current and shall be arranged for self-lubrication. xv) Proper weight screen shall be provided at the hoist way. xvi) Fire retardant compound coated traveling cable shall be used. xvi) 2 Phase Device Fire Man Drive and Fireman switch at ground floor xvii) Micro Movements L.E.D. based Buttons. xviii) Load Weighing device with overload bypass feature. (Audio Visual over load indicator in the car) xix) Steel items such as Door Frames Sill Angles, Fascia Plates, Spring Buffers. xx) Braille fixtures, Lift announcement system, Pit ladder, Hand rail, Pressure sensing device and Additional Car Gate Lock. xxi) Three Side Hand Rails in Stainless Steel Finish xxii) System Capable of withstanding plus 10% to –10% Variation in Supply Voltage Fluctuations. (C.V.T should be provided for Protection of lift against Single phase, Low voltage and over voltage) xxiii) Car Platform constructed out of Cold Rolled Grain Oriented Formed Sheets of Steel xxiv) Fire Rated Landing Doors for a Period of One Hour Only. xxv) The whole machinery shall be mounted on appropriate anti vibration supports to minimize voice and vibration. xxvi) A handrail not less than 0.60mtr long and 1.0 mtr. Above floor level shall be fixed adjacent to the control panel. xxvii) The time of automatically closing door shall be minimum 5 seconds and the closing speed shall not exceed 0.25mtr./ Seconds xxviii) Over speed governor (Electro-mechanical device that prevents free fall in case the lift is travelling at speed more than 10% of the rated speed in downward direction. xxix) All other required features relates the operation of lift by the Handicaps and Blind person and others as per instruction of lift inspector and HBC 2017. |
| 597 | Supply, Installation, Testing and Commissioning of 12 x 8 Networked Digital Signal Processor With AEC: Should have 12 or more floating AEC in group of 4 or more Channels: DSP with 12 inputs and 8 outputs or more: 12 Control Inputs and 6 Logic Outputs for GPIO Integration: 48V phantom power on all analog inputs: THD: (0.01% 20Hz to 20KHz: Crosstalk: (-75dB or better: Open architecture software configurable: Separate logic processing power: 2 digital audio bus RJ45 Port: 1 Ethernet port for Monitoring and configuration: Capable to handleplus 5V unloaded logic output voltage: Should have speech sense engine: Capable to control 3rd party devices with TCP IP and RS232: Should have 1nos of RS 232 port for integration with control System: Should have Bi-Directional Locate Functionality: Should have 48 or more digital audio Channel Bus: Should have monitoring LED for COM, STAT, ERR and PWR etc. |
| 598 | Supply, Installation, Testing and Commissioning of Input Expansion Unit with 8 - 10 Analog audio output: should be capable to route 256 or more audio Channels a CATX cable, Should have DIP Switches for easy configuration for audio channel routing: Height should not more than 1RU: Should supplied by same OEM of above requested chassis based DSP Unit, it will help to avoid any compatibility issue(s) during the time of installation and/or post installation etc. |
| 599 | Supply, Installation, Testing and Commissioning of Network Enable Wall mount Keypad Controller with 8 -10 Buttons: Should have PoE (Power Over Ethernet) port: Should have 8 - 10 Programmable Buttons (Multicolored): Capable to trigger any DSP logic: Multicolored 2 Programmable 64x128 Pixel LCDs: Sleep Function: Security: Remote Lock/Unlock and Local Unlock via PIN Entry: Should have knob and capable to control 8 zones separate: Should be from same OEM of supplied DSP Unit(s) to avoid any compatibility issue(s) etc. |
| 600 | Supply, Installation, Testing and Commissioning of bidirectional USB module for DSP connection to PC/Mac for soft conferencing. |
| 601 | Supply, Installation, Testing and Commissioning of Multiformat HDBT 4K Transmitter should support up to 4in x 1out audio and video switching, routed to the HDMI and HDBT output simultaneously, 3x HDMI input Type A Female Connector, 1x VGA Input, 1x Analog Stereo Inputs ,1x HDMI Outputs ,1x HD Base: supports digital video, audio,bidirectional control , USB2.0 extension and power , HDCP Support Yes: HDCP 1.4 and 2.2, Key Management System for Fast Switching: EDID Management A preferred EDID can be selected for each input or any display EDID can be mirrored to any input independently. |
| 602 | Supply, Installation, Testing and Commissioning of8x8 Matrix Switcher, it should support Minimum 8 HDMI input and 8 HDMI output with Video Input Port : 8xHDMI, Video Output Port : 8 x HDMI: Should support computer and video resolutions up to 4K/60 4:4:4 orbetter: Should support HDMI 2.0 with a data rates up to 18 Gbps ormore: Should support Front panel, IR, RS232 and Web based GUI control modes: Should support audio input format PCM 2-Channel, PCM Multi-Channel, Dolby Digital, Dolby Digital Plus, Dolby Atmos, Dolby True HD, DTS, DTS HD MA etc. |
| 603 | Supply, Installation, Testing and Commissioning of 4K60 Twisted Pair Transmitter , Shall have 4K60 4:4:4 transmitter which supports traditional HD Base T Outputs, and HDMI as an inputs: Shall have onboard USB 2.0 available on the HDBT allows for easy distribution of USB signals between the transmitter and receiver. A USB device, such as conferencing soundbar, can be mounted at the display and connected to a receiver. A laptop can then connect to the transmitter at the table, with USB and video distributed over category cable. It should support long distance transport of Ultra high resolution video, embedded audio, bidirectional RS-232 and IR and USB 2.0 over a single category cable. 4K60 4:4:4 and HDCP 2.2 Support over HD Base T with Display Stream Compression (DSC)– Visually lossless compression and future-proof support, Twisted Pair Cable Type Shielded Cat6, Cat6A and Cat7 / Shielded Cat6A and Cat7, Twisted Pair Cable Length Up to 70m - 100m or more, HD Base T Layer Throughput (Max) 10.2 Gbps,Shall have 1xHDMI , 1x HDBT Output , Shall serial port , Shall have IR TX and RX ports , Input Signal Type HDMI, HDCP DVI , Data Rate (Max) :18 Gbp ,Pixel Clock (Max) Up to 600 MHz, Regulatory Compliance CE, FCC, NRTL, RoHS, WEEE etc. |
| 604 | Supply, Installation, Testing and Commissioning of of 4K60 Twisted Pair Receiver,Should support traditional HD Base T as an input, and HDMI as an outputs to connect the display unit: Should have USB 2.0 Pass-through. It should support long distance transport of Ultra high resolution video, embedded audio, bidirectional RS-232 and IR and USB 2.0 over a single category cable. 4K60 4:4:4 and HDCP 2.2 Support over HD Base T with Display Stream Compression (DSC)– Visually lossless compression and future-proof support, Power over HD Base T – Can be powered from HD Base T inputs which means there is no need for an additional power source at the table ,Twisted Pair Cable Type Shielded Cat6, Cat6A and Cat7 / Shielded Cat6A and Cat7, Twisted Pair Cable Length Up to 70m - 100m or more, HD Base T Layer Throughput (Max) 10.2 Gbps,Shall have 1x HDBT, 1 x HDMI Output , Shall serial port , Shall have IR TX and RX ports , Input Signal Type HDMI, HDCP DVI , Data Rate (Max) :18 Gbp ,Pixel Clock (Max) Up to 600 MHz, Regulatory Compliance CE, FCC, NRTL, RoHS, WEEE etc. |
| 605 | Supply, Installation, Testing and Commissioning of Integrated Controller, Dual Network Interface card, Should support IPv6 , Shall Supports IEEE Standard for Port-based Network Access Control with the ability to grant or deny network access to devices wishing to attach to a LAN based on credentials tied to the device rather than to a user, Should have High Performance Architecture, Flexible Programming Platform Java, Should haveability to manage secure port TLS and SSH communications with a remote device or server, Enhanced Diagnostics On Serial and IR Ports , Hardware / Software should be Built for 24/7/365 Operation, Should have Ultra-Fast 1600 MIPS processor , 512 MB Onboard RAM , 1 M Non-Volatile Memory, 8 GB SDHC FLASH Memory ,1 RU Rack Space ,10/100 LAN Interface ,4 Digital I/O Ports , 1 RS-232/422/485 Port , 3 RS-232-Only Ports , 4 IR/Serial Output Ports , 4 Relay Ports Shall be supplied with OEM recommended power supply ,Regulatory Compliance :RoHS, WEEE etc. |
| 606 | Supply, Installation, Testing and Commissioning of External Power Supply Adapter for above Control Processor etc. |
| 607 | Supply, Installation, Testing and Commissioning of 10.1” or above Touch Panel: fully configurable: IPS LCD based Capacitive Multi-Touch with LED backlighting: Should support Any-Color Side LEDs: Ambient Light Sensor: Built-in Zoom Rooms Controller, Book Scheduling, Web Kiosk: Adjustable Security Modes, Resolution (WH) Landscape: 1920x1200, Aspect Ratio (WH) Landscape: 16:10, Brightness 350 cd/m2, Contrast Ratio 800:1, RAM4 GB, storage 16 GB, Ethernet RJ-45, POE 802.3af, 15.4W, Speakers 2 x 2 Watt, Compliance: UL, CE, CB, FCC Class B (-5dB) etc. |
| 608 | Supply, Installation, Testing and Commissioning of Tabletop Stand for above touch panel for desktop operations: should have the feature called as `Angle select` which allows to adjusted the position of a touch panel at a 30-, 45- or 60-degree angle from vertical etc. |
| 609 | Supply, Installation, Testing and Commissioning of PoE Injector for above touch panel etc. |
| 610 | Supply, Installation, Testing and Commissioning of 6 - 8 or more Button Keypad with volume knob: it should supplied with 3-Input Switching Wall plate Transmitter (2 HDMI, 1 USB-C) includes auto and manual switching modes, and support for transmission of uncompressed video and audio up to 40m/131ft at 4K or 70m/230ft at 1080P over shielded Cat 6/6A/7 cable: It should support supplied Multi-Function Receiver with Built-In 2x25W 4/8-ohm Amplifier, USB signal pass-through, RS232 control, Relay, IR, mic/line input, line out, remote mute, audio de-embedding, USB-AUDIO, ARC function, and CEC control (Embedded HD Base T™ technology allows for full usage of HDMI and controls over Cat 6/6A/7 cable). Web Configuration for simplified installation: should support OEM Specific Management PC tool included for campus wide room and device management etc. |
| 611 | Supply, Installation, Testing and Commissioning of4x4 Matrix Switcher, it should support Minimum 4 HDMI input and 4 HDMI outputShould support computer and video resolutions up to 4K/60 4:4:4 or better: Should support HDMI 2.0 with a data rates up to 18 Gbps or more: Should support Front panel, IR, RS232 and Web based GUI control modes: Should support audio input format PCM 2-Channel, PCM Multi-Channel, Dolby Digital, Dolby Digital Plus, Dolby Atmos, Dolby True HD, DTS, DTS HD MA etc. |
| 612 | Supply, Installation, Testing and Commissioning of wireless handheld microphone set with rack receiver having an automatic frequency and interference management, OLED display, Ethernet connectivity (IPv4 and IPv6), 256-bit AES encryption, Frequency range: 1,880 to 1,900 MHz, Frequency response: 20 to 20,000 Hz, Signal-to-noise ratio: ) 90 dB(A), RF output power:up to 80 mW or more, Dynamic range: ) 120 dB(A), Sampling rates: 24 bit/48 kHz, Connection: Audio Out: XLR 3M Audio Out: 2 x RCA Network: RJ 45 along with condenser type handheld transmitter with a super-cardioid pick-up pattern, sensitivity: 1.6mV/Pa, Maximum sound pressure level: 152 dB, RF output power:up to 80 mW or more, operating time:15 hour operation time. It should be remotely controlled with centralized software. |
| 613 | Supply, Installation, Testing and Commissioning of wireless Lavalier microphone set with rack receiver having an automatic frequency and interference management, OLED display, Ethernet connectivity (IPv4 and IPv6), 256-bit AES encryption, Frequency range: 1,880 to 1,900 MHz, Frequency response: 20 to 20,000 Hz, Signal-to-noise ratio: ) 90 dB(A), RF output power:up to 80 mW or more, Dynamic range: ) 120 dB(A), Sampling rates: 24 bit/48 kHz, Connection: Audio Out: XLR 3M Audio Out: 2 x RCA Network: RJ 45 along with Wireless Bodypack transmitter with condenser type omni-directional clip-on microphone, Sensitivity: 20 mV/Pa, Maximum sound pressure level: 130 dB, RF output power: up to 80 mW or more, operating time: 15 hours. It should be remotely controlled with centralized software. |
| 614 | Supply, Installation, Testing and Commissioning of 2 bay network charge, Remote Charging status Monitoring to OEM own software or third party controller, each bay should have 4 LEDs to indicate the corresponding battery status of the microphone, two hour or less for full charging, The charger shall have an RJ-45 network socket and shall support IPv4 and IPv6 network addressing. |
| 615 | Supply, Installation, Testing and Commissioning of HDMI to USB converter. |
| 616 | Supply, Installation, Testing and Commissioning of Metallic Audio Electronic Digital Podium, Display - High Sensitive, Built-In Speaker, Touch Type Monitor, Motorized Adjustable, Screen -Color Led: Scratch Resistant, Anti Glare and Vandal Resistant Glass, Size - 21.5 Inch Screen, Display Colors - 1 Billion Colors, Brightness - )450 Nits, Aspect Ratio(Typical) 16:9, Computer Interface - USB X1, HDMI X1, Response Time8MS or better , Viewing Angle - 170 (H) 160 (V), Touch Technology- Infrared Technology - Console Panel Display Ports -HDMI, USB X1, RJ 45 X1, Type/Mounting- Free Standing, Adjustable Tilt, Body Type - CRCA Steel Sheet, All Directional Wheel With Lock, Small Form Factor, Gooseneck Mic, Processor - Intel Core i5 , Ram 8GB , SSD 256, Port - HDMI X 1, VGA X 1, USB 3.0 X 1, USB 2.0 X 2, LAN, Wi-Fi Inbuilt, Audio - Line-Out X 1/ Line-In X 1 Keyboard and Mouse Provided, O/S - Windows 10 Pro Preloaded, Central Controller With Panel And video Scalar Feature. |
| 617 | Supply, Installation, Testing and Commissioning of Desktop Document Camera, 1/2.8` 8M CMOS Color Image Sensor, Pixels - 8.6 MP, Zoom - 30x, Resolution -XGA / 720p / 1080p / 2160p, Frame Rate - 30 fps for all resolution, Shooting Area Max. - 522 x 308 mm (20.5` x 12.1`), Input - HDMIx1 (Support 4K), HDMI Pass-Through, Output - HDMI2.0 x1 / VGA x1(up to 1080p) / USB 2.0 / IP Streaming, Control -RS-232 / USB / Ethernet, Supports HDMI, VGA, Ethernet, and USB output, Standalone Audio Video Recording on USB Drive, In-built Mic, Top Light x 2, In- built Backlight for X-rays, Negatives, Slides etc.OEM should be BIS, CE, RoHS and FCC Certified. |
| 618 | Supply, Installation, Testing and Commissioning of 19`Integrated LED LIFT with Touch screen , Screen 1920 X 1080 LED Widescreen, Screen thickness – 15mm, Screen Structure – Toughened glass in Front and black aluminum frame, Motor power – 18W 220V 50/60 Hz, Interface – VGA/HDMI Input, Door opening method- Upward opening door elevation angle: 12 degrees elevation, Control Mode- manual control, Remote control, 485 center control, Central control interface- Rs485 input and output. |
| 619 | Supply, Installation, Testing and Commissioning of Multiview with streaming solution for Video Conferencing with 4 x HDMI inputs and 1 x HDMI and 1 x USB 3.0 outputs supporting 18Gbps (600MHz) 4K UHD support, Seamless switching with no loss of sync to display when switching sources in 4x2 matrix mode, supports to store a multi-window arrangement as a preset, EDID management, Supports easy adjustment of window size, position and settings in the PiP windowing mode via the Web GUI and controllable via front panel buttons, Web GUI,Telnet, RS-232.Ability to automatically scales 4K sources to 1080p for USB capture with video timing stabilization to help ensure a reliable and stable USB capture stream, should support capturing 2 channel digital audio from either HDMI (LPCM 2.0) or the 3.5mm analog audio input (selectable via capture software). Compliance with the UAC (USB Audio Class) and UVC (USB Video Class) standards to support most common capture and video streaming. |
| 620 | Variable Refrigerant Flow System :- SupplyInstallationTestingandCommissioningof VariableRefrigerantFlowaircooledOutdoor Unitssuitablefor coolingand heating, having all hermeticallysealed invertertypeScroll/TwinrotaryCompressor(s) , microprocessorbased controller, top discharge type condensing units with R410 A refrigerant , vibration isolators with suitable foundation etc. completeasrequired. The Outdoor unit should have anti corrosive, fins along with auto dust removal as a standard feature. Theunit shalldelivertherated capacityat AHRIconditions andworkevenat50DegCambienttemperature withouttripping.The unitshallbesuitabletoworkon 400V plus /-10%3 phase , 50 Hz AC power supply. The COP at AHRIinCoolingmodeshouldnotbelessthan4.0 and IEER 7.2 at 100% . Each ODU whether connected in module to make bigger ODU should have Same make Compressor. 24 HP (Two or More ODU Unit) |
| 621 | 4- Way Cassette indoor unit :- SupplyInstallationTestingandCommissioningof followingminimum capacity 4-way flowVRV/VRFCassetteType Indoorceilingmounted unitequipped with syntheticwashablemedia pre-filter, fan sectionwith lownoise fan/dynamicallybalancedblower,multispeedmotor,coil sectionwithDX copper coil,electronicexpansionvalve,outercabinet, drain pump grill, necessary supports, vibration isolation, corded/Cordless remote controletcsuitableforoperationon 230 V plus -10%50Hz ACsupply. 4.0 TR Cassette A/C (With Sensing Panel) |
| 622 | 4- Way Cassette indoor unit :- SupplyInstallationTestingandCommissioningof followingminimum capacity 4-way flowVRV/VRFCassetteType Indoorceilingmounted unitequipped with syntheticwashablemedia pre-filter, fan sectionwith lownoise fan/dynamicallybalancedblower,multispeedmotor,coil sectionwithDX copper coil,electronicexpansionvalve,outercabinet, drain pump grill, necessary supports, vibration isolation, corded/Cordless remote controletcsuitableforoperationon 230 V plus -10%50Hz ACsupply. 3.0 TR Cassette A/C (With Sensing Panel) |
| 623 | High Static Ducted Units :- SupplyInstallationTestingandCommissioningof followingminimum capacity High StaticVRV/VRFDuctedType Indoorceilingmounted unitequipped with syntheticwashablemedia pre-filter, fan sectionwith lownoise fan/dynamicallybalancedblower,multispeedmotor,coil sectionwithDX copper coil,electronicexpansionvalve,outercabinet, drain pump grill, necessary supports, vibration isolation, corded/Cordless remote controletcsuitableforoperationon 230 V plus -10%50Hz ACsupply. 8.2 TR Ductable A/c |
| 624 | Supply, installation, testingand commissioningof factory fabricated Double Skin weather proof, outdoor type, Air- handlingunithorizontal type fabricated out of extruded aluminium section consistingwith 0.63 mm pre-plasticized/pre-coated Galvanised steel sheet outside and 0.63 mm plain galvanised steelsheetinsidewithblower,blowersection, fan motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply,Multi Row deep cooling coil made of Aluminium finned Copper tube withcoilsection,pre - filter section withnonwoven syntheticmedia of 10 micronparticlesizewith an efficiency of 90%, stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drivepackage etc. The AHU panels with thermal break profile insulated with (50±2) mm thick and 40 ± 2 Kg/m³ density PU foam. Themotor and blower assembly shallbemountedon Aluminium extruded sectiononly. The complete AHU shall conform to standard specification.Constructional Features of DOUBLE SKIN TYPE HORIZONTAL FLOOR MOUNTED AIR HANDLING UNITS.? Mixing box with manually operated fresh and return air AL dampers.? Filter section with 50 mm thick box type pre-filter. ? Coil section with multi-rows deep DX type cooling coil.? Fan section with SISW centrifugal direct driven plug fan,with VFD Unit and spring isolators.? Supply air manually operated AL damper. 29500 CFM / with AHU kit as per OEM Design. |
| 625 | Refrigerant Piping :- Supply installation Testing and Commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerantpiping forF/VRVsystem,completewithfittings,with suitableadjustableringtypehangersupports, ng/brazingincluding accessories insulated with XLPE Class O tubular insulation/with Class O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories.Size 12.70mm OD |
| 626 | Supply and fixing of following thickness duly laminated aluminium foil finish closed cell Nitrile rubber ( Class O) insulation on duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3mm thick self adhesivenitrile rubberinsulation complete as per specifications and as required. (a) 19 mm thick insulation with Aluminium foil. |
| 627 | Supply of Laying of 4 core 6 mm Sq copper cable complete in all respect to entire satisfaction of Engineer-in-charge. |
| 628 | Supply, Installation, Testing and Commissioning of Rodent System having following specifications: - Microprocessor based Main Panel / Controller wall mounting type with facility to connect 20 Transducers Operating Frequency ) 20Khz and ( 60 Khz. with 4 frequency bands Front Facia having LCD display and on board controls to view and operate the menu. Panel to be with power supply supporting 230V AC. Panel to have BMS Compatibility. (Up To 24 TRANSDUCERS ) TRANSDUCERS (12 nos.), BRACKETS (MS POWDER COATED), Standard 2 core 0.5sq. Mm PVC insulated wire complete in all respect. |
| 629 | Supply, Installation, Testing and Commissioning of Video wall having screen size29 x 11 Feet The pixel pitch should be 2.5 mm or better. The LED type is SMD 3 in 1. The LED configuration shall be 1 Red, 1 Green, 1 Blue. The cabinet design shall be fan less. The pixel density shall be 160,000 pixels per square meter or more. The half-gain horizontal and vertical viewing angles shall be H 150° and V 150° or better. The refresh rate shall be =3840 Hz or better. The grayscale processing shall be 16-bit or higher. The brightness shall be 800 cd/m² or higher, calibrated. The maximum power consumption during LED start-up shall be 347 W/sqm or lower. The average power consumption shall be 120 W/sqm or lower. The Video Inputs- HDMI 2.0 HDMI 2.0 (w/ HDCP 2.2) X 2, Display Port X 1, Outputs - RJ45/ Fiber Optics, The dimming capability shall have 256 levels. The operating temperature shall be 0°C to 40°C. The working humidity is 10% RH to 80% RH, The rated voltage shall be AC-230V±10% at 50/60Hz. The contrast ratio shall be 5000:1 or better. The access for maintenance shall be from the front. The IP level shall be IP20 or better. The lifespan shall be 100,000 hours or more. LED spares of 5% (modules) shall be provided at the time of delivery. Mandatory certifications CE, FCC, BIS, and UL, ISO 9001:2015, ISO 14001, ISO 45001. OEM must have a operational service center in state/ city from last 5 years, The mounting structure shall be made of MS or aluminum as per site requirements, 100% maintenance-free, with design flexibility, unaffected by humidity and water, durable to impact, requiring no polishing, and including fasteners or clamps. The brightness of the active LED Video wall of 800 nits must be measured by the OEM in the presence of the Engineer-in-Charge at the site using a luminance meter that gives output in cd/sqm or nits, not in Lux. Bidder must have to submit the ink signed MAF from respective OEM. |
| 630 | SITC of Main Electrical Panel (CPRI Approved manufacturer at leat 70 K)INCOMING SUPPLY :MCCB 630 Amps 65 KA 4 Pole Micro Processor Based Adjustable Type with Rotary Mechanism and all Protections along With Spreader Links etc: 1 NoMulti Fuction VAF/VIF Meter (96mmX96mm Size), Indication Lamps LED Type RYB, Control MCB SP for Control (3 Nos.) CT`s 600/5 (3Nos) and Control Terminal (8.0Nos) etc.Outgoing 20 No. 40-63 Amp TPNL MCCB with Adjustable Release 50 KA with ROM and Spreader Links S/c, O/L and Other Protections Outgoing for 24 HP ODU (12HP plus 12HP)All starter shall have following accessories :1 No. overload relay, 1 No. Ammeter with CTs., 1 No. single phase preventer, 2 Nos. ON/OFF indicating lights, 2 Nos. ON/OFF push buttons,Hardware (PVC Channels/MCB Channels/Fibre-Glass/Gaskits/Sleeves/nuts/Bolts/washers/cooling fans/etc) Complete Wiring inclusive of thimbles,etcupto entire satisfaction of Enigneer-In-Charge of the work.,The panel drawing shall be approved before taking up the fabrucation and shall have compitable BMS for future requiremnt. |
| 631 | SITC of DOL Starter (15KW), Outdoor Type. With Indication LED Lamps, Onand Off Switch With Allied Accessories Items For AHU Unit, complete in all respect to entire satisfaction of Engineer-in-charge. |
| 632 | CAR PARK VENTILATION SYSTEMSupply, installing, testing and commissioning of Analog type Carbon Monoxide based Gas detection system comprising of CO sensors, with DDC controller, built in power supply units. Detectors shall be mounted in enclosure with sensor lid projection at distance not more than 1500 mm from floor and shall have suitable arrangement to fix on wall or on ceiling as directed including SS 304 grill of size (200 x 150 x 125 mm) for protection. Sensor shall have range of 0-250 ppm non linear sensing, sensors shall be solid state type with operating temperature range of -10 to 50 deg C and relative humidity of 10% to 100% [noncondensing]. Enclosure shall be in minimum IP 55 construction. Seperate MS Powder Coated Junction Box shall be provided near each sensor for termination of armoured copper cable and final terminal inside sensor with flexible copper cable and IP 65 PVC glands . The Cost of CO senser , cabling , Conduit and supporting shall be included in this item . The CO senser location and technical details shall be approved by Consutlant based on design submitted by HVAC Vender. complete in all respect to entire satisfaction of Engineer-in-charge. |
| 633 | Supplying, installation, testing and commissioning of ceiling hung / floor mounted vane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiencyIE2 for Emergency Supply, Pressurization and Smoke Exhaust Fans and IE3 for Normal Supply, and Exhaust Fans suitable for 3 Phase 50 Hz 415V ± 10 %. Motor shall be class `F` insulation for Fresh Air and Pressurization Fans and class `H` insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications.Motor of exhaust fans shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs., Complete fan shall be AMCA certidied for Air and sound performance and CE listed in accordance in EN 12101-3:2015All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating/Powder coating after phosphating process and complete with bird screen at inlet with louver and fan protection coul. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order. Complete as required as per site conditions.18500 CFM / 18 MMWC TSP - For Fresh Air |
| 634 | Supplying, installation, testing and commissioning of ceiling hung / floor mountedvane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiencyIE2 for Emergency Supply, Pressurization and Smoke Exhaust Fans and IE3 for Normal Supply, and Exhaust Fans suitable for 3 Phase 50 Hz 415V ± 10 %. Motor shall be class `F` insulation for Fresh Air and Pressurization Fans and class `H` insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications.Motor of exhaust fans shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs., Complete fan shall be AMCA certidied for Air and sound performance and CE listed in accordance in EN 12101-3:2015All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating/Powder coating after phosphating process and complete with bird screen at inlet with louver and fan protection coul. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order. Complete as required as per site conditions. 18500 CFM / 18 MMWC TSP - Exhaust Air |
| 635 | Supplying, installation, testing and commissioning of ceiling hung / floor mountedvane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiencyIE2 for Emergency Supply, Pressurization and Smoke Exhaust Fans and IE3 for Normal Supply, and Exhaust Fans suitable for 3 Phase 50 Hz 415V ± 10 %. Motor shall be class `F` insulation for Fresh Air and Pressurization Fans and class `H` insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications.Motor of exhaust fans shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs., Complete fan shall be AMCA certidied for Air and sound performance and CE listed in accordance in EN 12101-3:2015All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating/Powdercoating after phosphating process and complete with bird screen at inlet with louver and fan protection coul. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order. Complete as required as per site conditions.22500 CFM / 18 MMWC TSP - For Fresh Air |
| 636 | Supplying, installation, testing and commissioning of ceiling hung / floor mountedvane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiencyIE2 for Emergency Supply, Pressurization and Smoke Exhaust Fans and IE3 for Normal Supply, and Exhaust Fans suitable for 3 Phase 50 Hz 415V ± 10 %. Motor shall be class `F` insulation for Fresh Air and Pressurization Fans and class `H` insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications.Motor of exhaust fans shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs., Complete fan shall be AMCA certidied for Air and sound performance and CE listed in accordance in EN 12101-3:2015All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating/Powdercoating after phosphating process and complete with bird screen at inlet with louver and fan protection coul. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order. Complete as required as per site conditions. 22500 CFM / 18 MMWC TSP - FOR Exhaust Air |
| 637 | Supply, installing, testing and commissioning of Jet Fan shall be provided with Dual Speed smoke spill motorwith class `H` insulation for smoke extraction.Complete fan alongwithmotor shall besuitable foroperation on 415±10% volts, 50Hz, 3 phase AC power supply and capable to withstand300 deg C temperature for a minimum duration of 2 hours. The Impeller of jet fan shall beAirfoil design with High efficiency blades.Jet Fans shall be made in single piece and shall supplied with silencers andfan should be within the silencer to avoid air, sound leakage .Fan shall be AMCA Certified for Air and Sound Performance.The fan shall be tested and certified for (F300)CE/UL Certified for smoke control and exhaust applications in accordance with EN 12101-3:2015 from notified body. Note:The motor make of smoke/exhaust fan shall be same as mentioned on the fire certificate of the fan provided by international independent laboratory under certifying authority. Quantity and location of jet fans will be finalized based on CFD analysis. complete in all respect to entire satisfaction of Engineer-in-charge. |
| 638 | SITC of Preparation and approval of CFD (Computational Fluid Dynamics) Analysis in Basement Zone. CFD analysis to decide the correct location and quantity of jet fans. CFD analysis will be carried out for both normal and fire mode ventilation situation considering 6/12 ACPH, airflow strategy and control strategy to confirm the operation logic. CFD analysis will model all the cars, car parking bays, beams, structures, columns, voids, shafts, ramps, proposed fresh air route, fresh air shaft, exhaust air shaft and preliminary location of jet fans shown in the drawing. CFD output will give complete simulation of ventilation scheme not limited to velocity profile, temperature profile, smoke temp and movement profile, CO level profile, air movement profile. The number of repeat simulations shall be carried out until satisfactory results are achieved. complete in all respect to entire satisfaction of Engineer-in-charge. |
| 639 | Supply, fabrication, installation and testing the flexible connectionsof fire resistance flexibledoublecanvassleeveasper the approved shop drawings. complete in all respect to entire satisfaction of Engineer-in-charge. |
| 640 | Supply, installation, testing and commissioning of package type/unitized 11kV / 433 V Outdoor sub-station, 800kVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specificationsfor the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation. Vacuum Interrupter, RMU, LT panel switchgear and CSS enclosure shall be of same make to ensure life cycle optimization.Make: Siemens/Schneider Infrastructure/ABB.Note: CSS shall be from OEMs only. Licensed System Integrators are not allowed to supply.Package substation will have the following equipment:-HT SWITCHGEAR: - 11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of2 nos. fixed manual operated Load Break Switch and1 nos. fixed manual operated Vacuum Circuit Breaker Module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil.Capacitive voltage indication fixed type system with LEDSF6 Gas pressure indicator.Padlocking facility.Protection CT shall be minimum 60/1A, 2.5VA, 5P10. - 3 nos.Operating Sequence of VCB shall be O-0.3sec-CO-3MIN-COLBS module will have FPI. All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER: - 800 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformerwith corrugated wall, without conservator, type of design and Top Bushings for HT and LT with On Load Tap Changer of ratingplus 10% to -10% @1.25%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date) Max Losses @ 50% Load 2147W and Max Losses @ 100% Load 5837 W and Impedance of 5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (Make of transformer: - NUCON/POWER STAR/DANISH/ As per OEM approved brands/ UHBVN/ DHBVN approved)- One No. Winding Temperature Indicator with Alarm and trip ContactLT PANEL: - LVS PANEL 2000 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. : LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER FROM TRANSFORMER: - 1600 Amps 433V 4P 50Hz 50KA EDO Air Circuit Breaker Ics=Icu=Icw=50 KA for 1 second based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releasesMultifunction meter of class 0.5 accuracy. - 1 No.All Civil works such as PCC/RCC foundation, Platform, Filling trench and pedestal etc as per CSS manufacturer`s recommendation are included in scope of work.OUTDOOR ENCLOSURE: - Outdoor type enclose of 1.5 mm (For non load bearing members) and 2.0 mm (For load bearing members) thickness having modular construction of Galvanized Sheet Steel in suitable design for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT and LT switchgear compartment and IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitably handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter, RMU, LT panel switch gear and CSS enclosure shall be of same make to ensure life cycle optimization. |
| 641 | Supply, Installation, Testing and Commissioning of Ceiling Hung Supply Air Axial flow fans of 20 mm WG static pressure completewith GSS casing, aluminiumalloy impellers,directlydriven by TEFC induction motor suitable at 415±10 % V,50 Hz, 3 Phase AC power supply, 1400 RPM, supporting frame,louvers, weld mesh inlet guard, TP isolator with MS enclosure box as required. Axial fansshall be AMCA and third party certified and should have rated motor and fan of Class- F complete in all respect to entire satisfaction of Engineer-in-charge. 32000 CFM |
| 642 | Supplying, Installation, Testing and Commissioning ofFloor standing Exhaust AirAxialflowfansof20mmWGstatic pressure complete with GSS casing, aluminiumalloy impellers,directlydriven by TEFC induction motor suitable for 415 V ± 10 %, 50 Hz ,3 Phase, 1400 RPM, supporting frame, Gravity louvers, weld meshinletguard,TPisolator withMS enclosure box as required etc. Axial fans for smoke ventilation shall be AMCA and third party certified andshould have fire rated motor and fan of Class- H suitable for working at high temperature (250 deg. C for minimum 2 hrs.) complete in all respect to entire satisfaction of Engineer-in-charge.32000 CFM |
| 643 | Supplying,Fixing, Testing and Commissioning of motorised fire dampers in supply air duct, return air duct as and where required inclusive of control wiring,the damper shall be motorized and spring returnsoastoclosethedamperin the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed/opened in the event of fire signal complete as required. complete in all respect to entire satisfaction of Engineer-in-charge. Actuator |
| 644 | Supply, Installation, Testing and Commissioning of Indoor type (T.T.A. PANEL) as per IEC/IS 61439- Part 1 and 2 Automatic Power Factor Correction panel (with detuned reactors) - 250KVAR. Supply, installation, testing and commissioning of powder coated (treated with 9 tank phosphating) with approved colour compartmentalized cubicle MV Panel fabricated out of 14/16 SWG thick CRCA sheet steel suitable for operation on 415 Volts, 50Hz, 3 Phase 4 wire AC supply . The panel shall be indoor free standing, floor mounting, dust and vermin proof type, adequate size cable alley with front operated rotary handles for MCCB`s complete with gland plates, lifting hooks, ventilating louvers, bus bars, Inter connections, earthing, labeling electrical interlocking ,suitable for termination of cables as per single line diagram including. Supply and fixing of following switchgear and accessories complete as required. A separate earth copper bus bar of size 25 mm x 5 mm to be provided throughout the length of the panel complete with both Electrically interlocking foolproof system. The Panel should be extendable type. All accessories included in the panel cost such as rotary handles, Spreader link and its accessories and metering and capacitor feeder etc. as mentioned. The panel should be got inspected / tested in the factory premises from the Engineer-in-charge / consultant before brought at site after approval of all drawings of the panel. ( Make of Panels :- Schneider / ABB / Siemens / LandT / Sudhir Power / Tricolite / Advance Power Control System / Milestone / Trisquare )CAPACITOR PANEL 250 KVAR shall comprise of following as mentioned :- MCCB 630 Amp TP 50KA complete with Spreader , Rotary Handle,Voltmeter with VSS , Ammeter with ASS , RYB Indication Lamp LED = 3 OS.,400/5Amp. 15 VA CL-1 Current Transformer = 3 NO. 06Amp. Control SP MCB = 8 NO., 12 stage APFC relay, Control Contactors etc.Each capacitor feeder shall consists of 14% detuned reactor , Heavy duty capacitor ( rated at 525 volt ) , capacitor duty contactor as per capacitor , Selector switch , On / Off indicator with Push buttons , MCCB ( 36 KA ), MCB (10 ka ) for capacitor rating less than 15 KVAR . Panel shall be made to work in auto as well as manual mode. Capacitors banks shall be 5 KVAR - 1 NOS. , 10 KVAR - 1 Nos. , 15 KVAR - 1 NOS. , 20 KVAR - 1 Nos. , 25 KVAR - 2 Nos. , 50 KVAR - 3 Nos. Panel shall have 600 amp aluminium bus bar ACCESSORIES Fabrication in 2mm CRCA Sheet Powder Coating in Siemens Gray Shade, 75x40mm.Channel Base Frame, Cable Entry will be Top and Bottom Suitable for Cable, Lock, Rubber Gasket, hardware etc. Aluminium Main Bus Bar, Load wise Sub Feeder Bus Bar Colour Coated Heat Shrink Bus Bar sleeves Nut-Bolt, Washer, Hardware etc. WIRING and ACCESSORIES Power and Control Wiring will be (ISI 1100V) flame smoke FRLS PVC Single Core Copper Wire, Copper Lugs, PVC Sleeve, Ferrules Numbers, Hardware and Labour etc. Net capacitor rating shall be 250 KVAR @ 440 Volt. |
| 645 | Supply, Installation, Testing and Commissioning ofIndoor type (T.T.A. PANEL) as per IEC/IS 61439- Part 1 and 2, with Aluminium TPN electrolytic grade Busbar 2000 Amp self standing indoor cubical main control confirming to IEC/IS 61439-1 and 2 specification for cubical panel fabricated out of 2mm thick CRCA sheet having with base frame made of 75 x 40 mm channel duly powder coated with shade of choice (pre treated with 9 tank pre treatment process). The panel shall have fire suppression system complete with tubes and cylinder duly filled. The panel should be complete in all respect as desired by the Engineer in charge of the work. ( Make of Panels :- Schneider / ABB / Siemens / LandT / Tricolite / Advance Power Control System / Milestone / Trisquare )Incomer Supply- From 800 kVA PSS (1 and 2 ) - 2 nos. each comprising of= 1 sets ACB 4 pole 1600 Amp., EDO Ics=Icu=Icw=50 KA for 1 second with microprocessor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases (MP-LSIG Release), 415 volts complete Set, Shunt Release 220V AC, Under Voltage Release, Aux. Block, Interlocking System, Control MCB 6A SP.10KA `C` Curve., Aux. Contactor, display for energy parameter with percentage loading of graph, last 10 trip history and ZSI, individual fault indicator, Digital Multifunction Meter, Digital Volt meter 0-500V, MCB 20/2Amp / SP for Control, Breaker Control Switch, Indication Lamp LED Type for RYB, LED Lamp 220V for ON / Off/Trip, CT`s - 1600/5, for Metering and APFCR with CT Shorting Links, Panel Light with accessories, Cooling Fan plus MCB and other accessories etc. Incomer Supply From DG ( 1 ands ) - 2 nos. each comprising of 1Sets ACB 4 pole 1250 amp., EDO with MP-LSIG Release, 415 volts complete Set, Shunt Release 220V AC, Under Voltage Release, Aux. Block, Interlocking System, Control MCB 6A SP.10KA `C` Curve, Aux. Contactor, Digital Multifunction Meter, Digital Volt meter 0-500V, MCB 20/2Amp / SP for Control, Breaker Control Switch, Indication Lamp LED Type for R,Y, B, LED Lamp 220V for ON / Off/Trip, CT`s - 1600/5, for Metering with CT Shorting Links, Cooling Fan plus MCB and other accessories etc. Bus coupler = 1 Set ACB 4 pole 1250Aamp., EDO with MP-LSIG Release, 415 volts complete, Shunt Release 220V AC, Under Voltage Release, Aux. Block, Interlocking System, Control MCB 6A SP.10KA `C` Curve., Aux. Contactor, Breaker Control Switch, MCB 6Amp / SP for Control., LED Lamp 220V for ON / Off/Trip.Outgoing Feeders- 1:-6 nos. 630A TP MCCB (36kA) with built-in Microprocessor Based Release (O/C, S/C) each comprising of spreader link, Rotary Handle. Digital Multifunction Meter with RS-485 communication port, Accuracy Cl.-1 (96mmX96 mm), 3 nos. CT - 600/5A, 5VA, Cl.-1 for Metering (Resin Cast) , 3nos. Indicating Lamps - ON, OFF,TRIP (220-240V AC), 4 nos. 6A SP Control MCB (10kA) C Curve, Outgoing Feeder 18 nos. each comprising of 100A TP MCCB (25kA) with TMD Based Release (O/C, S/C ) spreader link , extended rotary handle ,Aux Contact , Digital Multifunction Meter with RS-485 communication port, Accuracy Cl.-1 (96mmX96 mm) , 3 nos. CT - 100/5A, 5VA, Cl.-1 for Metering (Resin Cast) , 3 nos. Indicating Lamps - ON, OFF, TIRP (220- 240V AC), 4 nos. 6A SP Control MCB (10kA) C Curve. The Panel shall be complete with all the interconnections, interlocking of incomer’s aluminium bus bar connections etc. Panel shall be complete with PLC based auto load management with DG synchronization ( DEIF based AGC 150 relay - 2 Nos. ) including necessary control contactors, relays, timers, push buttons, control logic, commissioning on site etc. |
| 646 | SITC of Electrical Motor Control panel (MCC), made out of 2mm CRCA sheet finished with Grey Powder Coated painting with IP55 degree of protection comprising of incoming MCCB , Amp metering, outgoing feeders with MCB, Motor Starters DOL/ star delta starter comprising of contactors, relays, pushbutton station facility for remote Operation through push buttons/ BMS, Auto manual switches and safety devices complete at basement level. The panels shall be designed to suiting the requirement of Car parking Ventilation logic at all basements as per Technical Specifications and SLD. GA Drawing, SLD and Control Logic of panels to be submitted and approved prior to fabrication. Vendor shall verify the motor ratings as per the fan make /model selected and make necessary modifications as necessary) or single speed Exhaust Fans and Dual Speed Jet Fans. The single point incoming power will be supply by Electrical vender upto fan Electrical Panel. Further distribution shall be in scope of HVAC vender. (Including Panel, jet fan incoming power and communication cable, cable tray, conduit, panel) . (including all accessories)Incomer - 25 KWOutgoing - 7.5 KW X 2 Nos for Exhaust Fans. Outgoing – 2.0 KW X 5 Nos for Jet Fans. |
| 647 | Supply and charging of Refrigerant GasR- 410 for Top up in all respect as per requirement. |
| 648 | SITC of Grille/Diffusers/Dampers of Aluminum with powder coatingfor Lift Lobby pressurization system with necessary civil work as per drawings and specifications complete in all respect upto entire satisfaction of EIC. |
| 649 | Providing and fixing motorized volume control damper with necessary civil work as per drawings and specifications complete in all respect upto entire satisfaction of EIC. |
| 650 | SITC of TFA ID unit (1500 CFM, 6RD/8RD 65sp) complete in all respect including the cost of all material required for installation like supports, brackets and controller etc. upto the entire satisfaction of Engineer in charge. |
| 651 | Supply, installation, testing, and commissioning of CO2 monitoring system, inclusive of CO2 sensors and centralized controller, complete with wiring and accessories for minimum 16 sensors, as per specifications and approved drawings complete in all respect to entire satisfaction of Engineer-in-charge. |
| 652 | Supply, installation, testing and commissioning of Copper conductor cables PVC sheathed, armoured cables of 1.1 KV grade with copper lugs and flameproof brass compression glands on both the ends with inhibting compound and GI earthing, identification tags, clamps and saddles etc. (I) 4Cx 10 Sqmm Copper Armoured |
| 653 | SITC of RGBW LED PAR: Light Source: 54x3 W RGBW LEDs Lamp life: 50,000 hrs, Input Voltages: AC90-260V 50/60Hz, Power Consumption:. 170W, Strobe: high speed white color or color changing strobe with 1-13Hz frequency range, Dimmer: 0-100% electronic dimming Light Angle: 25°, Control: DMX512, master-slave and sound activated or auto operation, Channels: 7 DMX channels USITT DMX-512, Other Functions: LED display, IR Remote control (optional), automatic operation with built-in programs, efficient low noise cooling system IP20, Finish - Black, Certification: CE complete in all respect to entire satisfaction of Engineer-in-charge. |
| 654 | SITC of Video wall LED controller to maintain aspect ratio of 29 feet by 11 feet video wall screen with followingspecifications complete in all respect to entire satisfaction of Engineer-in-charge.1 Architecture Server Based architecture 4U2 Operating System Windows 10 Pro or higher -64bit3 RAM 16 GB4 SSD 950 GB or higher x2 Hot Swappable5 RAID RAID 16 Chip i7 / Xeon Processor7 Power Supply Maximum Power Consumption 500W : Dual Redundant Power Supply8 Output 4 with custom Resolution9 Inputs 04 HDMI Inputs ( FHD)plus4 VNC Sources10 PCIe Should have at least 2 PCIe x16 physical slots or higher11 Chassis 19` rack mount industrial chassis with front Lock12 Unix/Linux Emulation Should be possible to display images from Unix/Linux workstation13 Wall Management Software Software to be provided to manage the layout on the displayWALL MANAGEMENT SOFTWARE14 Scaling and display Software enable user to display multiple sources up to any size and anywhere on the display wall.( Pixel to Pixel )15 RS232, TCP/IP RS232 and TCP/IP support should be available for other interfaces16 Remote Control Controller can be controlled by Remote PC through LAN with MAC OS / OSX and WINDOWS17 Auto Source Detection Software should support for auto source detection18 Layout Management Should support for Video, RGB, DVI, ,Internet Explorer, Google Crome, Desktop Application and Remote Desktop Monitoring Layouts19 Scenarios ` Software should able to Save and Load desktop layouts from Local or remote machines`20 Layout Scheduler All the Layouts can be scheduled as per user convenience 21 Software should support auto launch of Layouts according to specified time event by user22 Launch Application Software should able to Support23 User friendly Software should be use friendly24 WebUI Software should support Web Based UI: can be opened for layout control and Create New Layout on windows, android, MAC OS25 Zoning Logical Division of Wall with ability to create layouts for specified logical zone without interference with other zone26 Multiple Video Wall Software should be capable to control multiple video wall from same software27 Licensing Software based licensing with lifetime license on same hardware28 Upgradability Complete System should be capable to add Inputs/Outputs in future29 Source Type Supported Hardware Inputs,Google Chrome, IE, Screen Scrapping,HTML5,RSSFEED,TICKER,RTP,RTSP,H.264/Video/Images30 Certification / Compliance BIS , ROHS , CE etc |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail