}

Tender For Construction Of Deficient Married Accn For Officers And Air Men At Af Stn Bareilly, bareilly-Uttar Pradesh

Military Engineer Services has published Tender For Construction Of Deficient Married Accn For Officers And Air Men At Af Stn Bareilly. Submission Date for this Tender is 05-05-2025. Building Work Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

48474972
Tender For Construction Of Deficient Married Accn For Officers And Air Men At Af Stn Bareilly
Open Tender
Indian
Uttar Pradesh
Bareilly
05-05-2025

Tender Documents

Tender Details

Tender For Construction Of Deficient Married Accn For Officers And Air Men At Af Stn Bareilly; 1 SCHEDULE A PART I (BUILDING WORKS) 2 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartI . 3 SCHEDULE A PART II (INTERNAL WATER SUPPLY) 4 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch ‘A’ PartII. 5 SCHEDULE A PART III (INTERNAL ELECTRIFICATIONS) 6 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONS as listed in Sch ‘A’ PartIII. 7 SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch ‘A’ PartIV . 9 SCHEDULE A PART V (EXTERNAL ELECTRIFICATION) 10 Lump sum price worked out by the contractor forEXTERNAL ELECTRIFICATION as listed in Sch ‘A’ PartV 11 SCHEDULE A PART VI (SEWAGE DISPOSAL) 12 Lump sum price worked out by the contractor for BSEWAGE DISPOSAL as listed in Sch ‘A’ PartVI 13 SCHEDULE A PART VII (AREA DRAINAGE) 14 Lump sum price worked out by the contractor for BAREA DRAINAGE as listed in Sch ‘A’ PartVII 15 SCHEDULE A PART- VIII (ROAD/PATH AND CULVERT) 16 Lump sum price worked out by the contractor for ROAD/PATH AND CULVERT as listed in Sch ‘A’ PartVIII 17 SCHEDULE A PART- IX (EARTHWORK AND SITE CLEARANCE) 18 Lump sum price worked out by the contractor forEARTHWORK AND SITE CLEARANCE as listed in Sch ‘A’ Part IX 19 SCHEDULE A PART- X (DEMOILTION AND DISMANTLING) 20 Lump sum price worked out by the contractor for Demoilition and Dismanting as listed in Sch ‘A’ Part X 21 SCHEDULE A PART- XI (FIRE FIGHTING) 22 Lump sum price worked out by the contractor for Fire fighting as listed in Sch ‘A’ Part XII 23 SCHEDULE A PART- XII (LIGHTIENING PROTECTION ) 24 Lump sum price worked out by the contractor for LIGHTENING PROTECTION as listed in Sch ‘A’ Part XII 25 SCH A PART XIII (LIFT AND DG SET) 26 Lump sum price worked out by the contractor for LIFT & DG SET listed in Sch ‘A’ Part XV 27 SCH A PART XV (HOT WATER SUPPLY) 28 Lump sum price worked out by the contractor forHOT WATER SUPPLY listed in Sch ‘A’ Part XV 29 SCH A PART XVI(MISCELLENEOUS B/R AND E/M ITEMS) 30 M&L forexcavation 100mm Dia bore holes completein any type of soil including removal of surplus soil to the distance of 50 m complete all as specified and directed 31 Material and labour for telephone point wiring with twin core telephone wire all as directed. 32 Supply and fix Decorative wall mounted luminaire made out of Metal and Glass ,busshed nicklewith unbreakable globe suitable for LED bulb and provn of LED bulb 12 watts B22 complete all as specified and directed.Philips cat part No.30950 or equivalent. 33 Supply and fixing of 1100 volts grade three singlecore having 1.50 Sq.mm multi-stranded copper conductor cable each, flexible PVC insulated and overall PVC sheeted round flexible connection s wire as in electric connections complete as sspecified and directed. 34 Supply, installation, testing & commissioning 11 kv, 360 amp load break switch platform mounted of size 1800 mm x 1200 mm x450mm suitable for 415 volts 3 phase 50 hz supply havingaluminum bus bar installed on porcelain/ epoxy insulator. LBS shall be dust proof, vermin proof(IP 64) and applying spray painting with two coats of synthetic enameled paint over a coat of red oxide primer on sheet and made of out of 3.15 mm thick CRCA sheet self molded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arrangement with 50mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified. The scope of work includes provision of housing with following accessories:- Earth switch alongwith HRC fuse, fuse trip mechanism, earth switch and electrical standard indication and shut trip and also having the following specification: (a) frequency: 50 HZ (b) Phase 3 phase (c) Material: Mild Steel (d) Voltage: 11000 volt Maximum relative humidity : 90% (f) surface finish: Powder coated complete all as specified and directed by Engineer-in-charge. 35 S&F wall mounted fan PVC body,300 mm sweep 3 speed control complete all as specified and directed. 36 S&F Electric Chimeny wall mounted auto clean curved SS material, minimum air flow1400 m3/hr, maximum 60 db sound level,Built in oil collecter,230 volts ac 50Hz complete all as specified and directed 37 S & F for parking tiles of size 300x300x10 mm thickness (Matt finish) as parking tiles, complete all as specified and directed 38 Supply ,install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 4 nos. energy meters of overall minimum dimension900mm (W) x 750mm (H) x 200mm (D) made out of 2.0 mm thickCRCASheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :-a) Four pole MCCB, 100 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No.b) Aluminium Bus Bar of 200 Amps duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos.c) MCB TPN 63 Amps, 10 KA - 4 Nos ( To be connected with 4 Nos Meters)d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights)e) Digital time switch 16 Amp-01 Nof)LED indicating Lamps,g) 3 Way Bakelite strip type cable connector 30 Amps rating - 06 Nosj) Internal wiringwith 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :-i) MCCB to Bus Bar - 16 Sqmm copperii) Bus Bar to Cable Connector via KWh meter and MCB - 10 Sqmmiii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm 39 Supply ,install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 4 nos. energy meters of overall minimum dimension 800 mm (W) x 500mm (H) x 300mm (D) made out of 2.0 mm thickCRCASheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :-a) Four pole MCCB, 40 Amps with breaking capacity 10 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No.(Incommer)b) Aluminium Bus Bar of 100 Amps duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos.c) MCB SPN 32 Amps, 10 KA - 4 Nos ( To be connected with 20 Nos Meters)d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights)e) Digital time switch 16 Amp-01 Nof)LED indicating Lamps,g) 3 Way Bakelite strip type cable connector 30 Amps rating - 04 Nosj) Internal wiringwith 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :-i) MCCB to Bus Bar - 10.0 Sqmm copperii) Bus Bar to Cable Connector via KWh meter and MCB - 4.0 Sqmmiii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm 40 M&L for earth work & cutting cast iron GI water mains pipesfortappingand reducing to required lenngth in position for insrtion ofteesfor branch connections of the internal dia pipe including Supply and fixing new tees upto 100x100x80mm of coller double side end socketand one side end flanged of using required lead joint etc all as specified and directed by eng-in-charge. 41 M & L for co axial cable RG6CU jelly filled, complete all as speciifed and directed 42 Supply installation, commissioning & testing electric driven mono block pump 5 HP with bronze impeller and SS shaft with electric motor 3 phase, 415 volt AC of suitable size capacity butnot less than 05 HP mounted on common base plate/ MS channel and PCC foundation of suitable size as per manufactureer recommendation and 400mm all around including jointing with delivery & suction with required Jointing ,material all as specified and directed. 43 Supply and fixing swing type single disc cast iron foot valve (IS 4038) with screwed ends size 110mm bore for iron -pipes complete are specified and directed 44 Supply, installation, testing and commissioning factory made LT feeder pillar box outdoor type platform mounted of size 1800 mm x 450 mm suitable for 415 volts 3 Phase 4 wire system 50 Hz supply having aluminium bus bar 400 Amps for phases and neutral, installed on porcelain/ epoxy insulator the panel shall be dust proof, vermin proof (IP54) and applying spray painting with two coats of synthetic enameled paint over a coat of red oxide primer on sheet and made of out of 3.15 mm thick CRCA sheet self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arrangement with 50 mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified. The scope of work includes provision of housing the following accessories:- 45 Supply, installation, connecting and testing swing check type reflex valves (Non return) cast iron body class PN 1.6 design with flanged ends drilled suitable for the size 80mm. Bore of pipes ISI marked (IS:5312:2004 part-1)complete with nuts bolts washers rubber gasket etc all as specified and directed. 46 Material & labour for construction of soakage well excavation of any typeof soil foundation in PCC 1:3:6 ,walls of honey combed and solid brick work in CM 1:4 ,RCC cover slab in M-25 /SFRC cover interconnecting pipes of RCC/DWC complete filled with brick bats,complete ofsize3.0 m dia X 4.5 m effective depth complete all as specified and as directed byEngineer-in-Charg. 47 S&F shock proof, rust proof, fire retardant non Transparent Kiosk pole box of size 310x210x120 mm made ofEngineering plastic one piece moulding, for out door duty, with four Nos.of Insulated aluminium bus bar of 60 Ampere capacity mounted on Unbreakable insulators, 10 Ampere MCB SP with aluminium lugs of suitable size up to 50 Sq.mm including 02 Nos. 40x3 mm flat iron clamps duly painted both side with tow coats of synthetic enamel paint over a coat of red oxide primer, necessary suitable size nut-bolts, washers etc. complete as specified and as directed. 48 M & L for 100 users convetional type RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc. complete with effective depth 1.5 Mtr and overall depth of 3 Mtr. 49 M&L for construction of block masonry valve pit chamber of size 950x950x950mm (internal dimensions) with 50 mm thick foundation using PCC 1:3:6 (type D-2), block masonry wall built in CM 1:4, 15mm thick internal plaster including top of floor in CM 1:4, finished even and smooth without using extra cement, and 20mm thick external plaster in CM (1:4) and 3.15mm thick MS sheet cover including 40x40x6mm MS angle frame fixed in PCC 1:2:4 type B-1 coping with 25x4mm flat iron hinges, hold fasts, handles, locking arrangements, applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer to all steel surface including excavation and earth work inany type of soil complete, as specified and as directed. 50 M&L for construction of block masonry valve pit chamber of size 1050x1050x1050mm (internal dimensions) with 100mm thick foundation using PCC 1:4:8 (type D-2), block masonry wall built in CM 1:6, 15mm thick internal plaster including top of floor in CM 1:6, finished even and smooth without using extra cement, and 20mm thick external plaster in CM (1:4) and 3.15mm thick MS sheet cover including 50x50x6mm MS angle frame fixed in PCC 1:2:4 type B-1 coping with 25x4mm flat iron hinges, hold fasts, handles, locking arrangements, applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer to all steel surface including excavation and earth work inany type of soil complete, as specified and as directed. 51 Supply, installation, commissioning and testing of factory made (CPRI approved IP 54) LT Panel indoor type of suitable size, structure fabricated from 2.0 mm PBI MS sheet and and doors are fabricated with 14 SWG MS Sheet including mild steel channel frame only at bas eof mounting on floor not less than 75x75x2mm thick grouted in PCC. the panel shall be made dust and vermin and weather proof by providing good quality gasket on doors removable cover, gland plates etc. The sheet panel metal work on of the panel will be powder coated for suitable protection against corrosion approved shades. The cabinet door will be provided with detachable type hings and flush type including flush cylinderical locks. Provision for cable entry shall be from either side. All joints and connections will be made by galvanised or cadmium plated high tensile nuts bolts and washers. Opening for natural ventillation shall be provided and ahve screen of perforated sheet. The panel shall confirm to IS-5039-(1983) suitable for housing and inclusive of the following:-(a) (I) MCB 4 pole 32 Amps 10 KA (for incoming -01 Nos)(b) MCCB 4 pole 40 Amps 10 KA (for outgoing -02 Nos)(c) MCB DP 10 AMps (10KA) (for Outgoing -01 Nos)(d) Ampere meter of range 0-30 Amps with selector switch-02 No(e) Volt meter 0-500 Volts 96 Sqmm flush mounted with selector switch-01No(f) Amunimium bus bar strip 100 Amps for 3 phase 4 wire system having 4 strips complete on insluator-01 No(g) DOL Starter suitable for 5 HP motor -2No(h) Wiring with single core copper conductor cable of suitable size bus bar to outgoing MCB/ Ammeter/ Voltmeter/ selector switches etc-01 JOb(j) Metallic cable glands for outgoing and incoming cable 1set(k) Pad lock 65mm GI with duplicate keys 1 Nos(l) Indicating lamp RYB-01 Nos.(m) Danger notice board should be displayed. 52 M&L for bus duct typically uses sheet metal, welded or cast resin to contain and isolate copper or aluminium bus bars for th epurpose of conducting a substantial current of electricty, complete all as specified and directed. 53 Taking down and shifting of 16 mtr high mast shaft suitable for 50 m / Sec wind speed with raising loweing system comprising head frame, luminares carriage suitable to install 12 Nos luminiaries in symmetrical arrangement, double drum winch 6 mm diameter stainless steel wire rope, trailing cable connector integral power tool room, manual handle, junction box, lightening finial and other accessories including dismantling of foundation and making good the disturbed surfaces, complete all as specifed and directed. 54 M & L for construction of shallow foundation with reinforced concrete M 20 design mix (using stone aggregates), cocrete for the High Mast considering the safe bearing capacity at site as 10 Ton / Sqm at 2 mtr depth with all material and labour involve in the work with and including erection of High Mast (Obtained from above item) with the help of suitable tools and plant, wiring of luminiaries with all wiirng material like PVC insulated PVC sheathed flexible cable of copper conductor of cross section 1.5 Sqmm lugs, MCB including provn of GI pipe medium grade, earthing for High Mastearth terminal with25x3 mm GI earth flats (02 Nos) with installation of high mast feeder pillar by grounting the stand in cocrete as per the Manufacturer instruction and as per the direction of Engineer - in - Charge. 55 Supply, installation, testing and commissioning factory made LT feeder pillar box outdoor type platform mounted of size 1800mm x 1200mm x 450mm suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminum bus bar 200 Amps for phase and neutral, installed on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP54) and applying spray painting with two coat of synthetic enameled painting over a coats of red oxide primer on sheet and made out of 3.15 mm thick CRCA sheet selfmoldedtype and 50x50x6mm angle iron frame front and rear opening with double shutter and locking arrangement with 50mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified. The scope of work includes provision of housing the following accessories:-INCOMING(i) MCCB having current rating 100 Amp. 4 Pole of breaking capacity 25 kA-01 No.(ii) Volt meter 0-500 Volts, Square flush pattern, digital type-01 No(iii) Amp meter square flush pattern 0-600 Amps digital type-01 No(iv) Indicating lamp LED type one set in incoming phases.(v) Internal wiring with PVC insulated copper conductor multi stranded cable1100 volts grade IS 694 marked.OUTGOING(i) MCCB having current rating 40 Amp. 4 pole of breaking capacity 10 KA-04 Nos(ii) MCCB having current rating 32 Amp. 4 pole of breaking capacity 16 KA-01 Nos(i) Provn of space for MCCB -01 No 56 Supply, installation, testing and commissioning factory made LT feeder pillar box outdoor type platform mounted of size 1200mm x 1000mm x 450mm suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminum bus bar 200 Amps for phase and neutral, installed on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP54) and applying spray painting with two coat of synthetic enameled painting over a coats of red oxide primer on sheet and made out of 3.15 mm thick CRCA sheet selfmoldedtype and 50x50x6mm angle iron frame front and rear opening with double shutter and locking arrangement with 50mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified. The scope of work includes provision of housing the following accessories:-INCOMING(i) MCCB having current rating 100 Amp. 4 Pole of breaking capacity 25 kA-01 No.(ii) Volt meter 0-500 Volts, Square flush pattern, digital type-01 No(iii) Amp meter square flush pattern 0-600 Amps digital type-01 No(iv) Indicating lamp LED type one set in incoming phases.(v) Internal wiring with PVC insulated copper conductor multi stranded cable1100 volts grade IS 694 marked.OUTGOING(i) MCCB having current rating 40 Amp. 4 pole of breaking capacity 16 KA-02 Nos(ii) MCCB having current rating 32 Amp. 4 pole of breaking capacity 16 KA-01 Nos(i) Provn of space for MCCB -01 No 57 Supply, installation, testing and commissioning factory made LT feeder pillar box outdoor type platform mounted of size 1200mm x 1000mm x 450mm suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminum bus bar 200 Amps for phase and neutral, installed on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP54) and applying spray painting with two coat of synthetic enameled painting over a coats of red oxide primer on sheet and made out of 3.15 mm thick CRCA sheet selfmoldedtype and 50x50x6mm angle iron frame front and rear opening with double shutter and locking arrangement with 50mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified. The scope of work includes provision of housing the following accessories:-INCOMING(i) MCCB having current rating 250 Amp. 4 Pole of breaking capacity 36 kA-01 No.(ii) Volt meter 0-500 Volts, Square flush pattern, digital type-01 No(iii) Amp meter square flush pattern 0-200 Amps digital type-01 No(iv) Indicating lamp LED type one set in incoming phases.(v) Internal wiring with PVC insulated copper conductor multi stranded cable1100 volts grade IS 694 marked.OUTGOING(i) MCCB having current rating 125Amp. 4 pole of breaking capacity25 KA-01 No(ii) MCCB having current rating 160 Amp. 4 pole of breaking capacity 25 KA-01 Nos(i) Provn of space for MCCB -01 No 58 Supply, installation, testing and commissioning factory made LT feeder pillar box outdoor type platform mounted of size 1200mm x 1000mm x 450mm suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminum bus bar 200 Amps for phase and neutral, installed on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP54) and applying spray painting with two coat of synthetic enameled painting over a coats of red oxide primer on sheet and made out of 3.15 mm thick CRCA sheet selfmoldedtype and 50x50x6mm angle iron frame front and rear opening with double shutter and locking arrangement with 50mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified. The scope of work includes provision of housing the following accessories:-INCOMING(i) MCCB having current rating 125 Amp. 4 Pole of breaking capacity 25 kA-01 No.(ii) Volt meter 0-500 Volts, Square flush pattern, digital type-01 No(iii) Amp meter square flush pattern 0-600 Amps digital type-01 No(iv) Indicating lamp LED type one set in incoming phases.(v) Internal wiring with PVC insulated copper conductor multi stranded cable1100 volts grade IS 694 marked.OUTGOING(i) MCCB having current rating 100Amp. 4 pole of breaking capacity25 KA-01 No(ii) MCB TPN having current rating 20 Amp. 4 pole of breaking capacity 16 KA-02 Nos(i) Provn of space for MCCB -01 No 59 Supply, commissioning erecting and testing complete of OEM manufactured, static silent (sound proof enclosure) Diesel Engne driven Generating set of capacity 50 KVA/40KW, water cooled, 415 volts (AC three phae, 4 wire sysyem of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with complete with conrtol panel standarized by manufactured, of adequate capacity for 8hrs running fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete and suitable at BKT Lucknow (capcity of engine, alternators shall worked out taking all derating factors into consideration) including foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height) as per manufacterer recommendation, anti-vibration pads complete all as specified and directed, confiriming to emission norms (No + HC < 4.0, Gm/Kwhr CO < 3.5gm/Kwhr, PM<0.2gm/kwhr, smoke limit< 2.7m-1) inclusing all feature tol comply with latest CPCB IV guidelines and comprising of followings :- 60 (A)DIESEL ENGINE :Diesel Engine 1500 RPM, direct injection, multi cylinders, four stroke, conforming to IS:100001/ISO3046/BS:649/BS:5514 amended upto date, for continious running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive ALternator capable of delivery 50KVA at outdoor atmospheric conditions at BKT Lucknow ( taking all derating factor into consideration) fitting with the following accessories subject to the design of manufacturer: -(i) Dynamically balanced fly wheel.(ii) Air Cleaner oil bath type(iii) Suitable Governer class 1A with backup Mechanical class 1A Flywheel with starter ring(iv) Dry exhaust amnifold with suitable exhaust residential grade silencer to reduce the noise level(v) Radiator cooling(vi) Radiator fan with guard(vii) Vaccum indicator(viii) Fuel filter and fuel houses 61 (B) ENGINE INSTRUMENT PANEL digital type having facility for automatic/manual starting, reset switching with an indicating the following including internal control wiring controlled with MCB & connected to safety features of Engine & Alternator :- 62 (i) Starting switch on/off 63 (ii) Water temp guage 64 (iii)Hour meter cum RPM indicator 65 (iv) Lub oil pressure gauge 66 (v) Lub oil temperature guage 67 (vi) Battery charging meter 68 (vii) Safety alarm against high water temp and lub oil pressure(viii) Any other tem not included/speciified but is a standard design pf the manufacturer. 69 (C)ALTERNATOR : Shall be self excited, self regulated, bush less for 50 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with + 1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 4722 complete- 1 No. Note : Aletrnator should be able to deliver output reading at actual site condition. 70 (D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of .suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No NOTE:- Cost of suitable size of PCC foundation including 400mm extra pcc platform around the DG set from outside of the canopy is deemed to be included in the unit rate quoted by the contractor. 71 (E) Bottom mounted (or as per manufacture design) steel fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 12 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete.Bypass arrangement by providing seperate panel made out of 3mm thick CRCA sheet, outdoor type with connection copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R,Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity 80 Amp is to be installed near AMF panel complete all as specified and directed.(i) Hour run meter(ii) Any other item not included/specified but is a standard design to the manufacturer 72 (F) AMF CONTROL PANEL : Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubiocal automatic mains failurewith degree of protection IP 42 conforming to IS 2147, suitable for 50 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting comprising of suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bar as approved with and including the following accessories as under:- 73 (i) Master switch for auto/manual/reset/off- 01 No 74 (ii) Ammeter digital type 96x96 mm to read 0 - 500 amps with CTs 1 set of 3 Nos, aux supply 230 volts, AC, accuracy class 1.0 75 (iii) Voltmeter digital type,96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0 76 (iv) Digital frequency meter -01 No. aux supply 230 volts, AC 77 (v) Push button start, stop,reset - 01 No 78 (vi) Set of lamp for indicating load asset , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure 79 (vii) Battery charger, connected to load. 80 (viii)Transformer of adequate rating. 81 (ix)Rectifiers 82 (x)DC Ampere and volt meter 83 (d)Charger rate selector for trickle or high charging 84 (e)Indicating lamp for battery charging 85 (viii)Fault accept/reset push button 86 (ix) Set of relays and contactor suitable for 50KVA DG set for automaitc start and auotmatically shutdown of suitable rating and capacity adjustable to 70% to 100% and 02 Nos MCCB 4 Pole 80 Amps,, 25 KA fixed on main supply and DG set supply. 87 (x) Make /Design of AMF control panel shall be as per Oem recommendation. 88 M&L for provision of mounting stand for air termination rod(as per sl item no. 2 above) made out of GI tubing 15mm bore medium grade ISI marked 1.5mtr long welded with GI strip 20x4mm making four legs for fixing vertically on and including pocerlein/epoxy insulator and fixed on PCC block size 300x3000x200th mm complete all as specified and as directed. (Note : PCC shall be measured and paid seperatly under slm item no.4 of schedule.) 89 M&L for PVC insulated copper conductor flat submersible cable 1100 volts grade of 10 Sqmm 3 core size drawn through PVC conduit fixed on wall with all accessories to connect tarrace pump complete all as specified and as directed. 90 Supply and fix cast iron air realease valve with single air outlet confirming to IS 4845 of size 20 mm dia bors and fixing up in MS pipe 100 mm bore complete set , all as specified and directed. 91 S & F branch piece pipe with nozzle of 20 mm dia for hose real conforming to IS 8090 complete all as specified and directed. 92 Supply, laying & testingPVC insulated, PVC Sheathedcable galvanized steel strip or wire armoured, electric control cable (Heavy duty) with stranded copper conductor of size 4 Core, 4 Sq mm 1100 Volts grade for connection to repeater panel from main panel all as specified and directed. 93 Supply a glow in dark FIRE EXIT sign board with man running arrow symbol and stair of dimension 12 X 6 X 8 mm decorative transparent acralic, including fixing arrangment all as specified and directed complete, all as specified and directed. 94 Supply, Installation, Testing and commissioning of 120 Watt Amplifire complete, all as specified and directed. 95 Supply & fixing of public Address wire 2 Core in PVC condute pipe for talk back facility complete, all as specified and directed. 96 Supply, Installation, Testing and commissioning of4zone selector with rack for mounting Amplifer complete, all as specified and directed. 97 S & F 15mm bore brass Wall Mixer 3-in-1 system with provision for both Hand Shower and Overhead Shower complete with 115mm long bend pipe, connecting Legs, wall flange mixing hot and cold waterscrewd down for 20mm dia CPVCpipe incl necessary fittings, (cat part No FLR-5281N), with hand shower 100mm dia round shape single flow (ABS body chrome plated with grey face plate) with rubit cleaning system (cat part No HSH-CHR-1937)with flexble shower tube 12mm dia & 1.5m long with nuts (cat part No SHA-CHR-549D12) with wall bracket for hand shower 35mm dia 100mm long round shape (cat part No SHA-555-CHR) &Overhead Shower 120mm round shape single flow ABS body with SS face plate chrome platated with rubit cleaning system (cat part No. OHS-CHR-1663) with shower arm 20mm dia, 300mm long round shape with 90 degree bend with flange SS complete all as specified and directed (cat part No : SHA-CHR-479L300S)of Jaquar/ equivalent make of Grohe / Kohler 98 Supply and fixed 15mm bore brass Wall Mixer 2-in-1 system with provision for Overhead Shower complete with 115mm Long Bend Pipe, connecting Legs, Wall Flange (cat part No FLR-CHR-5273UPR) with Overhead Shower 120mm round shape single flow ABS body with SS face plate chrome platated with rubit cleaning system (cat part No OHS-CHR-1663) with shower arm 20mm dia, 300mm long round shape with 90 degree bend with flange SS (cat part No SHA-CHR-479L300S) mixing hot and cold water, screwd down for 20mm dia CPVCpipe incl necessary fittings complete all as specified and directed of Jaquar/ equivalent make of Grohe / Kohler 99 Supply and fix 15mm bore brass C.P. Single Lever tall Basin Mixer without Popup waste system with 450mm long braided Hoses screwed down for 20mm dia CPVCpipe incl necessary fittings, cat part No FLR-CHR-5005NB complete all as specified and directed of Jaquar/ equivalent make of Grohe / Kohler 100 Supply and fix 15mm bore brass C.P. Single Lever Basin Mixer without Popup Waste system with 450mm long braided Hoses screwed down for 20mm dia CPVCpipe incl necessary fittings complete all as specified and directed , cat part No FLR-CHR-5001B of Jaquar/ equivalent make of Grohe / Kohler 101 S & F 15mm bore wall mounted brass C.P. sink mixer with regular swinging spout with connecting legs and wall flanges screwed down for 20mm dia CPVCpipe incl necessary fittings complete all as specified and directed, cat part No : FLR-CHR-5309Nof Jaquar/ equivalent make of Grohe / Kohler 102 S & F Brass chromium plated angular stop cock with wall flange screwed for 20mm dia CPVCpipe incl necessary fittings complete all as specified and directed, cat part No. FLR-5053N of Jaquar/ equivalent make of Grohe / Kohler 103 S & FBrass chromium plated bib tap screwed for 20mm dia CPVCpipe incl necessary fittings complete all as specified and directed, cat part No: FLR-CHR-5047N of Jaquar/ equivalent make of Grohe / Kohler 104 S & F brass chromium plated angle valve suitable for water supply connection to RO equipment, screwed for 20mm dia CPVCpipe incl necessary fittings all as specified and directed. 105 Supply, Installation, Testing and commissioning ofSingle master and 8 way slave for talk back system complete as required ( Control Room) 106 Suppy, installation, commisionig and testing cubical pannel board 3 phase 4 wire 415 volt AC 50 Hz, factory made indoor type fabricated with 2mm thick CRCA sheet dust and vermin proof duly powder coating painted over a coat of red oxide primer having bus bar chamber with 4 Nos 100 Amps copper bus bar on appoxi insulator 1100 volt grade, mounted on angle iron frame made out of 40x40x5mm angle iron 300mm high above floor level and grouting 150mm in PCC on all four corners with and including internal connections using copper cable/wire/bus bar and following items. 107 INCOMING:-(a) MCCB 63 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity , 16 KA with adjustable thermal magnetic setting– 01 No.(b) Indicating lamps LED type for three phases-R Y B of 3 Nos,(c) Digital Voltmeter 96x96mm to read phase and line voltage 500 volts with built in selector switch, aux supply 230 volt AC-01 No. 108 OUTGOING:-(a) Digital amp meter size 96x96mm CT operated, 3 phase, aux supply 230v AC, with built in selector switch - 2 Nos.(b)MCB TP40 Amps 10 KA - 02 No. (c) Star delta starter 3 phase 415 volt air break type capacity suitable to operate 10 HP motor- 02 Nos (d)MCB SPN 32 Amps 10 KA 2 Nos. 109 Supply and fixing Fire Extinguisher, water stored pressure type, 9 Ltrs cap, confirming to IS 15683 110 Supply and fixing Fire Extingusher CO2, 9 Kg cap, confirming to IS 15683 (Light Wt Squeeze grip type) 111 Supply and fixing Fire Extinguisher, Dry chemical Powder, (ABC) Type, 4 Kg cap, confirming to IS 15683 112 Supply and fixing Fire Extinguisher, Mechanical foam type, 9 liters cap, confirming to IS 15683 113 Supply and fixing Fire Bucket dry sand, 10 Ltrs cap, confirming to IS 2546 114 Supply and fixing fire point on walls consisting of Light weight squeeze grip type CO2 fire extinguisher conforming to IS 15863 capacity 3 Kg 115 M & L for cutting into existing man hole for connecting new drains of internal diameter 150 mm bore, making good to pipe, rendering and cuting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4, type B 1 finished even and smooth and reforming benching as required,complete all as specified and directed. 116 Sch A Part XVII(PRIME COST SUM FOR MODULAR KITCHEN) 117 Lump sum price worked out by the contractor for Prime Cost Sum for Modular kitchen work as per latest norms and standard.Estimated cost for modular kitchen inserted by MES = Rs 670000.00. Note :- The amount to be quoted by the Tenderer in BOQ against the inserted price by the department shall be restricted to Maximum 15% over and above the prime cost sum, accordingly the tenderer shall quote the amount.

Key Value

Document Fees
INR 3000 /-
EMD
INR 1266300.0 /-
Tender Value
INR 18.82 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail