Tender For Provn Of Storage Sheds Under Ge (S) Udhampur; 1 Sch A Part-I(Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 2 Construction of block of Storage Shed including ramp & steps complete all as shown on drawings andas specified. 3 TotalAmount of Sch A Part - II (Site Clearance) 4 TotalAmount of Sch A Part - III (Internal Electric Supply) 5 TotalAmount of Sch A Part - IV (Protective Work) 6 TotalAmount of Sch A Part - V (Area Drainage Work) 7 TotalAmount of Sch A Part -VI (Road and Hard Standing Work) 8 TotalAmount of Sch A Part - VII (External Electric Supply Work) 9 TotalAmount of Sch A Part - VIII (Lightning Protection Work) 10 TotalAmount of Sch A Part - IX (Fire Shed Work) 11 Sch A Part - X (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 12 Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, mediumgrade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40mm bore upto 7.5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion, complete all as specified and as directed. 13 Rectangular PVC insulators for aluminium strip complete all as specified and directed. 14 Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, mediumgrade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40mm bore upto 7.5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion, complete all as specified and as directed. 15 Supply, installation, testing and commissioning factory made and tested, CPRI approved LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC Supply System,dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings MCCBs areto busbar spadles to fitted complete base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entryand locking arrangement complete with following :-Incoming(a)MCCB 100 A4 pole with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 25/26 KA-01 No.Outgoing (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 150 Amp,4 pole, not less than 75 cmlong mounted on insulators -01 set. 16 Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal andearth work.(ii) Panels shall be placed above 0.6mtr from ground level.(iii) Outgoing MCCBs shall be fixed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables.(v) Cable glands for incoming LT cable 95 sqmm -01 No and out going cables 70 sqmm -02 No,50 sqmm - 01 Noand 25 sqmm -04 No are included in the rate quoted by Contractor 17 Flame proof point wiring for One light/fan point controlled by oneflame proof switch 16 Amp one way with 1.5 Sqmmsingle core multi standed copper conductor FRLSH insulated and unsheathed heavy duty cable in colour code including earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated drawn into and including concealedin ERW steel conduit of not less than 20mm dia and 1.5mm wall thickness ISI marked terminated into flame proof terminal boxes for mounting of flame proof fitting and fixtures etc., complete all as specified and directed. 18 All as per Srl item No. 15.00 here-in-before but with 2.5 sqmm copper conductor for 15 Amp socket with 2.5 sqmm earth continuity conductor. 19 Sub main wiring with four run of FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6 Sqmm, 1100 Volts grade and two run of 6 Sqmm FRLSH PVC insulated unsheathed as earth (In green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including drawing in ERW steel conduit 25mm dia, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles complete in all respect all as specified and directed. 20 Earthing complete with galvanized steel earth plate electrode600mmx600mmx6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 21 Sub main wiring with four run of FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4 Sqmm, 1100 Volts grade and two run of 4 Sqmm FRLSH PVC insulated unsheathed as earth (In green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including drawing in ERW mild steel conduit 25mm dia, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles complete in all respect all as specified and directed. 22 Flame proof wall mountingfan, 0.25HP, AC single Phase, 230V, oscillating 450mm sweep suitable for wall mounting complete all asdirected. 23 Flame proofMCB SPN DB 12 way enclosure size: 330mm x 350mm x 190mm lighting distribution board with complete internalbus bar and wiring up to terminals including chassis wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.Incoming:- MCB, 2P,63 Amp - 01 NoOutgoing:- MCB, SP, 6 Amp - 10 No 24 Flame proofMCB TPN DB 4 way enclosure size : 420mm x 420mm x 250mmlighting distribution board with complete internalbus bar and wiring up to terminals including chasis wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Incoming:- MCB, 4P,63 Amp - 01 NoOutgoing:- MCB, 1P, 6 Amp - 12 No 25 Supply and fixing flame proofMCB SPN DB 6 way enclosure size: 300mm x 300mm x 190mm lighting distribution board with complete internalbus bar and wiring up to terminals including chassis wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Incoming:- MCB, 2P,32 Amp - 01 NoOutgoing:- MCB, 1P, 6 Amp - 4 No 26 Double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as spd and directed. 27 Double walled corrugated (DWC) pipe of size 50 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as spd and directed.