| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,modular plate suitable GI box, and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group C) |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required |
| 3 | Group C |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 5 | 3 x 1.5 sq. mm |
| 6 | 3 x 4 sq. mm |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 8 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 9 | 2 x 4 sq.mm + 1 x 4 sq.mm earthwire |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | 25 mm |
| 12 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 13 | 40 A |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 15 | Single Pole |
| 16 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 17 | 40A |
| 18 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required(DSR-2018) |
| 19 | (a)5/6 A switch |
| 20 | (b)3 pin 5/6 A socket outlet |
| 21 | Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required. |
| 22 | 4 module |
| 23 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(DSR 2018) |
| 24 | 15/16 A switch |
| 25 | 6 pin 15/16 A socket outlet |
| 26 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 27 | 12 Way Double door |
| 28 | Earthing with G.I. Earth pipe 4.5 mtr. Long, 40 mm dia includingaccessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal or coke and salt as reqd. |
| 29 | Providing & Laying earth connection from earth electrode with 6 SWG dia G-1 wire in 15 MM dia G- 1 pipe from earth electrode including connection with G-1 thimble excavation and refilling as reqd. |
| 30 | Providing & Laying 6 SWG dia G-1 wire on surface / recess for loop earthing as reqd. |
| 31 | S/F of phenolic laminated sheet 3 mm thick complete with cuttingfixing etc as required.(MR) |
| 32 | Supplying and fixing single module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 33 | Supplying, Installation, Testing & Commissioning of 4 feet nominal size LED batten having extruded PVC housing, colour temperature 6500K having wattage not more than 20 watt and lumen out put not less than 1800 luman directly on ceiling / wall including, connection with 1.5 sq.mm, FRLS PVC insulated copper conductor single core cable and earthing etc. as required. |
| 34 | P/F of 1200 mm sweep super white ceiling fan complete with capacitor, double ball bearing stantdard size of down rod, conopies, three nos. Blade made of aluminium alloy suitable for operation on single phase 230 watt AC 50 Hz (without regulator) |
| 35 | P/I/T/C of 25 Watt LED energy saving street light luminaire made up of aluminium alloy housing with acrylic cover IP-66 On the existing bracket and connection with suitable copper conductor wire complete as required |
| 36 | Supplying and fixing of 32 mm dia * 0.75 metre long G.I pipe(medium class ) bracket for mounting of LED street light fitting on pole including bending the pipe to the required shape ,2 nos 40 mm * 3 mm flat iron clamps with nuts bolts and washer ,painting the flat iron with primer and finish paint etc as required |