Tender For Re-Electrification Work In New Tehsil Building, Tehsil Sandila District Hardoi - Wiring for light point with 1.5 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 2 Wiring for twin control light point with 1.5 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 3 Wiring for Fan point with 1.5 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 4 Wiring for Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 5 Wiring for Exhaust fan with 1.5 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 6 Wiring for LED Street Light Point with 1.5 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 7 Witting for circuit/ Submain wiring alongwith earth wire with the following sizes of KRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required. 8 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 9 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 10 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 11 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 12 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 13 2 X 16 sq.mm + 1 x 6 sq. mm earth wire 14 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 15 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 16 S/F of 12 way SPN DB with additional metallic Double door without MCB Cat-A 17 S/F of 8 way SPN DB with additional metallic Double door without MCB Cat-A 18 S/F of 4 way TPN DB with additional metallic Double door without MCB Cat-A 19 S/F of 4 way VTPN DB with additional metallic Double door without MCB Cat-A 20 Supply and fixing of call bell of approved make on polished MDFEG/ Teak ply board Complete all respect. 21 Installation of exhaust/Fresh air fan in the existing opening including making good the damage connection testing commissioning etc as required. 22 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. 23 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 24 Supply and drawing 1x1.5sqmm FRLS PVC insulated copper conductor single core cable for invertors 25 S/F of6 to 32 Amp SPMCB 26 S/F of 100 Amp 4 pole MCCB 27 S/L & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providingand fixing 25 A modular socket outlet and 25 A modular SP MCB C curve including connections, etc. as required. For A.C 28 Providing and laying G.I Strip 32mm x 6mm from earth electrode directly in ground as required. 29 S/F of Brass Compression gland & Aluminum Lugs 30 95sqmm 3-1/2 core 31 70sqmm 3-1/2 core 32 50sqmm 3-1/2 core 33 25sqmm 3-1/2 core 34 6sqmm 2 core 35 10sqmm 2 core 36 S/F of 16 SWG MS drum with Luvers duly painted including marking hole in the wall for fresh air/exhaust fan and finishing properly complete in all respect. 37 Supplying and fixing following rating, double pole (single phase and neutral) 240 V, residual current circuit breaker (RCCB) having a sensitivity current 30 mAin the existing MCBDB complete with connections, testingand commissioning etc. as required.40 Amp DP RCCB 38 Supplying and fixing following rating double pole 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 39 40 Amp 4PMCB Isolator 40 100 Amp 4PMCB Isolator 41 SITC of 1200mm Sweep BEE 5 Star Rated BLDC Fan 42 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 43 Supply of Exhaust Fan 300mmSweep 900/1400RPM 44 S/F of Modular Computer board 45 Supply and Laying of Aluminum conductor PVC insulated armored served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top On surface the cable run shall be fixed on M.S clamps etc of suitable sixe or as directed by Engineer in charge complete in all respect including exaction and refilling. The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 46 95sqmm 3-1/2 core 47 70sqmm 3-1/2 core 48 50sqmm 3-1/2 core 49 25sqmm 3-1/2 core 50 Supply and fixing of LED tube Light with heavy duty metal Box type Tube Light fitting 1x22 watt suitable for up to 1x22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete all respect 2620 system lumens, ˃120Lm/WPF˃0.95, THD <10% CRI <80, sheet thickness min 0.8mm, Tube with aluminum heat sink,˃300V over voltage protection, 2.5 KV internal surge Protection, with 5 year warrantee. 51 Supply, Installation, Testing and Commissioning of LT Panel vermin proof floor mounting, M.S channel base with bottom and Fabricated out of 2.0/11.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineering-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted don proper interval to ensure the bear the jerks of short Circuit of 50KA for panels having ACB as Incomer & 36KA for panels having MCCB Incomers Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be complete in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering. Incoming 400Amp MCCB-1 No,Outgoing200Amp MCCB 1 No.,100Amp MCCB 2 Nos. & 63Amp MCCB 1 No. 52 Supply, Installation, Testing and Commissioning of LT Panel vermin proof floor mounting, M.S channel base with bottom and Fabricated out of 2.0/11.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineering-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted don proper interval to ensure the bear the jerks of short Circuit of 50KA for panels having ACB as Incomer & 36KA for panels having MCCB Incomers Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be complete in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.Incoming 200Amp MCCB-1 No,Outgoing 100Amp MCCB 2 No., 53 Supply and fixing of LED street light fitting with mandatory driver set having die cast aluminum body with toughened glass/ UV stabilized PC Cover and lenses suitable for 75 watt to 90watt and confirming to IP 66, and LK07 and above protection having company LOGO Engraved complete in all respect including labour.9000-10800 system lumens High Power LED with lenses 120 Lm/w PF>0.95, THD <10% at full load, CRI >70, Potted driver set in metal housing (not circuitry) phase to phase projection at 440 V & >300V auto cut & re-start feature, with 5 years warrantee. 54 SITC of Grid Connected Rooftop solar Plants 55 L/C or dismantling of old wiring and accessories with required labour T&P etc complete in all respect. 56 GST @ 18% (from Item no. 1 to 37)