}

Tender For Provision Of Central Mi Room At Sigar Mil Stn Under Ge 872 Ews, Lower Siang-Arunachal Pradesh

Military Engineer Services has published Tender For Provision Of Central Mi Room At Sigar Mil Stn Under Ge 872 Ews. Submission Date for this Tender is 08-04-2025. Civil Work Tenders in Lower Siang Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

48174550
Tender For Provision Of Central Mi Room At Sigar Mil Stn Under Ge 872 Ews
Open Tender
Indian
Arunachal Pradesh
Lower Siang
08-04-2025

Tender Documents

Tender Details

Tender For Provision Of Central Mi Room At Sigar Mil Stn Under Ge 872 Ews; 1 Total amount of Sch A Part-IBuilding WorksNote :- This schedule is not pre-priced by MES and the rate indicated as Rs. 0.00 under column 6 signifies this fact only. 2 Soil investigation, Design, Fabrication and Construction of CENTRAL OF MI ROOMin RCC Framed Structure as per Arch Drg No. CWE/DIN/15/25 sheet No. 1/3 to 3/3 dated 20.01.2025 AND CWE/DIN/15/25 sheet No. 1/1 dated 20.01.2025 and specification given in Sch A Notes and Particular Specifications including complete RCC foundation and plinth, Flooring, Joinery and Finishes complete all as specified. NOTE : Soil investigation will be measured and paid separately.(i) Size – As per Arch drawing(ii) Height – 320 CM(iii) Fdn – To be design as per SBC report with RCC framed construction.(iv) Plinth – Burnt Brick wk in CM 1:6(v) DPC – 40 mm thick PCC 1:2:4 with WPC(vi) Super Structure – All RCC structure to be M25 design mix burnt brick wk wall upto ceiling.(vii) Seismic Zone – Strengthening measures for Zone V(viii) Roof – 0.50mm thick Pre-painted Galvalume sheet with MS steel frame structure, (ix) Ceiling : False ceiling with powder coated snap grid frame work. (ix) Internal Plaster – Internal 15 mm thick in CM (1:6)(x) Flooring – Coloured vitrified tiles in all room, verandah & non skid ceramic tiles in toilet and bathroom over 15 mm thick screed bed in base of CM 1:6 over a layer of PCC 1:2:4 over sub base of 1:5:10.(xi) Dado/Skirting – Glazed ceramic tails over 10 mm thick cement screed in CM (1:3) up to lintel height.(xii) Joinery – Frames – pressed steel, shutter – Factory made flush door shutter (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2) & PVC doors in toilet bathroom(xiii) Joinery Window – Steel Window with Guard bars/grill (TD Drg No CESZ/2015/TD/19 Sheet No 1R/3, 2R/3 & 3R/3)(xiv) Steel Guard – MS Guard bars to window(xv) Iron monger – Prefabricated aluminum anodized fittings. (TD Drg No CESZ/2015/TD/03 Sheet 1/2 & 2/2)(xvi) Plinth Protection – 75 mm thick PCC 1:3:6 over stone hard core.(xvii) Painting – Synthetic enamel paint on steel/wooden surface.(xviii) Finishes – Internal - 02 coats of oil emulsion distemper incl 1mm thick wall care putty over a coat of primer.External - 02 Coats of weather proof exterior emulsion over one coat of primer. (xix) Antitermite treatment- As per IS-6313 Part-II : 2001 (xx) Mosquito proofing - All external doors & Windows (xxi)18mm thick granite over CM 1:3 for steps(xxii) Sanatory Fitting – Vitreous China EWC, WHB ect of approved make including plumbing work (TD Drg No CESZ/TD-38 Sheet No 1/2& 2/2 andTD Drg No CESZ/TD-31 Sheet No 1/2& 2/2).(xxiii) Mosquito Proofing – All external Door and window. 3 NOTE: Schedule ‘A’ Part IItoIXare Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured. 4 Total amount of Sch ‘A’ Part II (Excavation and Earthworks) 5 Total amount of Sch ‘A’ Part III (Internal Electrification) 6 Total amount of Sch ‘A’ Part IV (Internal Water supply) 7 Total amount of Sch ‘A’ Part V (Path with interlocking paver block) 8 Total amount of Sch ‘A’ Part VI (Sewage Disposal) 9 Total amount of Sch ‘A’ Part VII (Area Drainage) 10 Total amount of Sch ‘A’ Part VIII (External Water Supply) 11 Total amount of Sch ‘A’ Part IX (External Electrification) 12 SCH A PART X(Miscellaneous B/R and E/M works)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 6 signifies this fact only 13 M & L for boring 100 mm dia hole in all kind of soil upto maximum depth 10 meter or up to refuse (N=100) whichever meet earlier including collection of undisturbed sample from cohesive soil only conducting standard penitration test at 12 meter and 1.5 meter interval alternatively as per relevant IS code complete all as directed. 14 Conducting necessary lab test on selected soil sample (obtained from item here in before) as per relevent nature moisture content, bulk and dry density sleve and hydrometer analysis, liquid and plastic limit, SP gravity unconfined compressive test (UU) or direct consolidation test etc complete all as relevant IS codes or all as specified and directed. 15 Completion of field work & lab test result and submission of report in Per Job quadruplicate suggesting depth of foundation type of fundation and safe bearing capacity with CD-1 (one) copy complete all as specified and directed. 16 Supply, installation, testing and commissioning factory made LT feeder pillar box Outdoor type suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminum bus bar 400 Amps for phases andneutral, install on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP54) and painted with two coats of syntheitc enameled paint over a coat of red oxide primer and made out of 3.15mm CRCA sheet self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arrangement with 50 mm lock make Navtal/Harrison and including grouting of panel with necessary PCC work icomplete all as specified.The scope of work includesthe following accessories with ciruit breakers :-Incoming : - (i) MCCB 4 pole 16 kA,415 Volts,3 phase 63 Amps - 01 Nos(ii) Digital Multi function meter showing :- Volt meter 0 to 500 Volts, Amp meter 0 to 200 Amps – 01 Nos (iii) Indicating lamp LED type one set in incoming phases. (iv) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs. (v) Connection from MCCB to Busbar shall be of solid Aluminium conductor. (vi) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable.Outgoing :-(i) MCCB 4 pole 16 kA,415 Volts, 3 phase 40 Amps - 03 Nos (ii) MCB SPN, 240V, 10 KA, 32 Amps - 03 Nos 17 S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 310x210x120mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. and duly Painted on Both Sides with Two Coats of Synthetic Enemel Paint over a Coat of Red Oxide Zinc Chrome Primercomplete all as specified and as directed. 18 M&L for GI bracket fabricated out of light grade GI Tubing of 32 mm dia, 1.5 mtr long of one sided Arm type and along with 02 sets of suitable size of clamps and nut & bolts to fix the bracket on steel tubular pole and inclusive of one primer coat, one under coar and one finishing coat of paint (synthetic enamel) complete all as specified and directed. 19 S&F PVC insulated FRLS copper conductor Wire 1.0 Sqmm, 3 Core, multistranded cable for Providing Connection from Street Light Fitting to Overhead Line/ Junction Box complete all as specified and as directed. 20 Supply and installation of Wall mounted split units indoor/outdoor complete with cordless remote control unit and with in built airioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TRcomplete all as specified and direced. 21 S & F Voltage stabilizer for automatic operation, air cooled indoor type& designed for input variation between up to 140 V to 280 V with output voltage stabilized at 230 Vwith accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and direced. 22 S & F Voltage stabilizer for automatic operation, air cooled indoor type& designed for input variation between up to 140 V to 280 V with output voltage stabilized at 230 Vwith accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and direced.

Key Value

Document Fees
INR 1000 /-
EMD
INR 172750.0 /-
Tender Value
INR 98.50 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail