Construction Of Shed Over Artificial Insemination Crate Inside The Different Govt. Animal Health Centres Within The Districts Of West Bengal For 2024-25 , Civil Works , Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil (Including Mixed Soil But Excluding Laterite Or Sandstone) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete. (A) Depth Of Excavation Not Exceeding 1,500 Mm , Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm As Directed And Consolidating The Same By Thorough Saturation With Water, Ramming Complete Including The Cost Of Supply Of Sand. (Payment To Be Made On Measurement Of Finished Quantity) , Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming And Dressing Bed To Proper Level And Filling Joints With Local Sand. , Cement Concrete With Graded Stone Ballast (40 Mm Size Excluding Shuttering) In Ground Floor (A) [Pakur Variety] , Supplying And Laying Polythene Sheet (150Gm / Sq.M.) Over Damp Proof Course Or Below Flooring Or Roof Terracing Or In Foundation Or In Foundation Trenches. , Ordinary Cement Concrete (Mix 1:1.5:3) With Graded Stone Chips (20 Mm Nominal Size) Excluding Shuttering And Reinforcement If Any, In Ground Floor As Per Relevant Is Codes. (Pakur Variety) , Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc Initial Straightening And Removal Of Loose Rust (If Necessary), Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Intersection, Complete As Per Drawing And Direction. I. Sail/Tata/Rinl [For Contractor Supply] , (A) For Works In Foundation, Basement And Upto Roof Of Ground Floor/Upto 4 M , (I) Tor Steel/ Mild Steel , Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4 M Using Approved Stout Props And Thick Hard Wood Planks Of Approved Thickness With Required Bracing For Concrete Slabs, Beams And Columns, Lintels Curved Or Straight Including Fitting, Fixing And Striking Out After Completion Of Works (Upto Roof Of Ground Floor) , 25 Mm To 30 Mm Shuttering Without Staging In Foundation , Labour For Chipping Of Concrete Surface Before Taking Up Plastering Work. , M.S. Structural Works In Roof Trusses With Tubular Sections Conforming To Is: 806-1968 & Is: 1161- 1998 Cnnected To One Another With Bracket, Gusset Cleats As Per Design, Direction Of Engineer-In-Charge Complete Including Cutting To Requisite Size, Fabrication With Necessary Metal Arc Welding Conforming To Is: 816-1969 & Is: 9595 Using Electrodes Of Approved Make And Brand Conforming To Is:814- 2004, Haulage, Hoisting And Erection All Complete. The Rate Includes The Cost Of Rolled Steel Section, Consumables Such As Electrodes, Gas And Hire Charge Of All Tools And Plants And Labour Reqired For The Work Including All Incidental Chages Such As Electricity Charges, Labour Insurance Charges Etc. , Supplying, Fitting & Fixing Zn-Al Alloy (55% Al & 45% Zn) Coating Of 150 Grams Per Sq. Metre (Followed By Colour Coated On Both Side) Steel Sheet Work Having Minimum Yield Strength Of 550 Mpa Of Trapizoidal Profile Of Approved Make (Excluding The Supporting Frame Work) Fitted And Fixed With 55 Mm & 25 Mm Self Tapping Screw, Epdm Washer 16 Mm Dia & 3 Mm Th. Washer Etc. Complete With 150 Mm End Lap And One Corrugation Minimum Side Lap. (Payment To Be Made On Area Of Finished Work). (I) In Roof:- A) With 0.5 Mm Thick Sheet , Brick Work With 1St Class Bricks In Cement Mortar (1:6) (A) In Foundation And Plinth , 125 Mm. Thick Brick Work With 1St Class Bricks In Cement Mortar (1:4) In Ground Floor. , Plaster (To Wall, Floor, Ceiling Etc.) With Sand And Cement Mortar Including Rounding Off Or Chamfering Corners As Directed And Raking Out Joints Including Throating, Nosing And Drip Course, Scaffolding/Staging Where Necessary.(Ground Floor).[Excluding Cost Of Chipping Over Concrete Surface] , (Ii) With 1:4 Cement Mortar. , (B) 15 Mm Thick Plaster , Neat Cement Punning About 1.5Mm Thick In Wall,Dado,Window Sill,Floor Etc. Note:Cement 0.152 Cu.M Per100 Sq.M. , (A) Priming One Coat On Steel Or Other Metal Surface With Synthetic Oil Bound Primer Of Approved Quality Including Smoothening Surfaces By Sand Papering Etc , Painting With Best Quality Synthetic Enamel Paint Of Approved Make And Brand Including Smoothening Surface By Sand Papering Etc. Including Using Of Approved Putty Etc. On The Surface, If Necessary : With Other Than Hi-Gloss Of Approved Quality- (Iv) Two Coats (With Any Shade Except White) , Holding Down Bolt With Nut Including 100 X 100 X 6 Mm Plate Washer At Bottom Fitted Complete And Packing The Hole With Cement Concrete Or Cement Grout As Directed. (I) 16 Mm Dia Bolt (A) 300 Mm Long , Taxes & Duties , Add: G.S.T. @ 18% Of Rs.58,684=73I.E. Rs. 10,563=25 , Add: Labour Cess @ 1% Of Rs. 69,247=98 I.E. Rs. 692=48 , Construction Of67 Nos. Of Shedover Artificial Insemination Crate Inside The Different Govt. Animal Health Centres Within The Districts Of West Bengal ( Multiplication Of 67 Sum 1.00 To 1.23 + Tax For 1 Unit)