| Sl. No. | Item Description |
| 1 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared. |
| 3 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. |
| 4 | Beyond 30 cm girth up to and including 60 cm girth |
| 5 | Beyond 60 cm girth up to and including 120 cm girth |
| 6 | Beyond 120 cm girth up to and including 240 cm girth |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 8 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 10 | 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 11 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 13 | Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 14 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. |
| 15 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 16 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
| 19 | Suspended floors, roofs, landings, balconies and access platform |
| 20 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 21 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 22 | Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 23 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 24 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 25 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). |
| 26 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 27 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 28 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : |
| 29 | cement mortar 1:4 (1 cement : 4 coarse sand) |
| 30 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinalpartitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finishedsmooth. |
| 31 | White Agaria Marble Stone |
| 32 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 33 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 34 | Kiln seasoned and chemically treated hollock wood. |
| 35 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) |
| 36 | Kiln seasoned and chemically treated hollock wood.(i)30 mm thick shutters |
| 37 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 38 | Kiln seasoned and chemically treated hollock wood. |
| 39 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 40 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 41 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 42 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 43 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 44 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 45 | 125x64x1.90 mm |
| 46 | 100X58X1.90 mm |
| 47 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 48 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 49 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 50 | 300x16 mm |
| 51 | 250x16 mm |
| 52 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 53 | 300x10 mm |
| 54 | 250x10 mm |
| 55 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 56 | 125 mm |
| 57 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 58 | Providing and fixing to existing door frames. |
| 59 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 60 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 61 | 80x1.20 mm M.S. laths with 1.20 mm thick top cover. |
| 62 | Providing and fixing ball bearing for rolling shutters. |
| 63 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 64 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 65 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 66 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : |
| 67 | 4.0 mm thick glass panes. |
| 68 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 69 | 40 mm thick with 20 mm nominal size stone aggregate |
| 70 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 71 | Glazed Vitrified tiles Matt/Antiskid finish of size(i)Size of Tile 600 x 600 mm |
| 72 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 73 | Size of Tile 600 x 600 mm |
| 74 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer-in-charge. |
| 75 | Size of Tile 600 x 600 mm |
| 76 | Painting top of roofs with bitumen of approved quality @ 17 kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : |
| 77 | With residual type petroleum bitumen of grade VG - 10 |
| 78 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design |
| 79 | In 75x75 mm deep chase |
| 80 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 81 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. or PVC rain water / sanitary / water supply pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : |
| 82 | 100 or 110 mm diameter |
| 83 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i)Single socketed pipes. |
| 84 | 110 mm diameter |
| 85 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 86 | Coupler (i)110 mm |
| 87 | Single tee with door (i)110x110x110 mm |
| 88 | Bend 87.5° (i)110 mm bend |
| 89 | Shoe (Plain) (i)110 mm Shoe |
| 90 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 91 | 110 mm diameter |
| 92 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 93 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 94 | Gutter (600 mm over all girth). |
| 95 | 12 mm cement plaster of mix : |
| 96 | 1:6 (1 cement: 6 fine sand) |
| 97 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 98 | 1:6 (1 cement: 6 fine sand) |
| 99 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 100 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 101 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 102 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 103 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 104 | New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 105 | Applying priming coat |
| 106 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 107 | Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. |
| 108 | 100 mm diameter pipes . |
| 109 | 150 mm diameter pipes . |
| 110 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 111 | Two or more coats on new work. |
| 112 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : |
| 113 | New work |
| 114 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 115 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 116 | With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre. |
| 117 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 118 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 119 | One or more coats on old work. |
| 120 | French spirit polishing : |
| 121 | One or more coats on old work. |
| 122 | Polishing on wood work with ready made wax polish of approved brand and manufacture : |
| 123 | Old work . |
| 124 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : |
| 125 | Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. |
| 126 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead : |
| 127 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 128 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 129 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 130 | Renewal of old putty of glass panes (length) . |
| 131 | Cleaning and de-silting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 132 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial de-silting of manholes and de-chocking of sewer lines. De-chocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth. |
| 133 | Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits.(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. |
| 134 | (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. |
| 135 | Dismantling 15 to 50 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin-Charge. |
| 136 | (a) Internal Work- Exposed on wall |
| 137 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 138 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : |
| 139 | 3 mm thick |
| 140 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead and 20 metres lift as per direction of Engineer in-charge |
| 141 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead and 20 metres lift as per direction of Engineer - in - charge. |
| 142 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 143 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead and 20 metres lift as per direction of Engineer - in- charge. |
| 144 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge. |
| 145 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead and 20 metres lift as per direction of Engineer-in-charge.. |
| 146 | In cement mortar |
| 147 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): |
| 148 | From brick work in cement mortar |
| 149 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: |
| 150 | Of area 3 sq. metres and below |
| 151 | Of area beyond 3 sq. metres |
| 152 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead and 20 metres lift in: |
| 153 | R.S. Joists |
| 154 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 155 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead and 20 metres lift . |
| 156 | For thickness of tiles 10 mm to 25 mm |
| 157 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead and 20 metres lift |
| 158 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead and 20 metres lift . |
| 159 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead and 20 metres lift: |
| 160 | 100 mm dia pipe |
| 161 | 150-160 mm dia pipe |
| 162 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead and 20 metres lift as per direction of Engineer-in-charge: |
| 163 | Up to 150 mm diameter |
| 164 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead and 20 metres lift . |
| 165 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead and 20 metres lift |
| 166 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead and 20 metres lift as directed by Engineer-in-charge. |
| 167 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 168 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 169 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 170 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : |
| 171 | W.C. pan with ISI marked white solid plastic seat and lid |
| 172 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 173 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : |
| 174 | Orissa pattern W.C. pan of size 580x440 mm |
| 175 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 176 | 10 litre capacity - White |
| 177 | Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : |
| 178 | White solid plastic seat with lid |
| 179 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 180 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 181 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : |
| 182 | Flat back wash basin of size 550x400 mm. |
| 183 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 184 | Flexible pipe (i)32 mm dia |
| 185 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 186 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 187 | Providing and fixing toilet paper holder : |
| 188 | C.P. brass |
| 189 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : |
| 190 | 100 mm dia pipe |
| 191 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 192 | Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms. |
| 193 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 194 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 195 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2\" BSP thread and shapes. Weighing not less than 60 gms. |
| 196 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 197 | 15 mm nominal outer dia. Pipes. |
| 198 | 20 mm nominal outer dia. Pipes. |
| 199 | 25 mm nominal outer dia .Pipes. |
| 200 | 40 mm nominal outer dia. Pipes. |
| 201 | 50 mm nominal outer dia. Pipes. |
| 202 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 203 | 40 mm nominal bore |
| 204 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 205 | 45 cm length (i)15 mm nominal bore |
| 206 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : |
| 207 | 40 mm nominal bore. |
| 208 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 209 | 15 mm nominal bore. |
| 210 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 211 | 15 mm nominal bore. |
| 212 | Cutting holes up to 30x30 cm in walls including making good the same: |
| 213 | With common burnt clay F.P.S. (non modular) bricks. |
| 214 | Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. |
| 215 | Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) : |
| 216 | With 20 mm diameter round bar |
| 217 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 218 | For fixed portion (i)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 219 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). (i)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 220 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 221 | Pre-laminated particle board with decorative lamination on both sides. |
| 222 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 223 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 224 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 225 | Grading roof for water proofing treatment with |
| 226 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 227 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 228 | 75 mm average thickness |
| 229 | 50 mm average thickness |
| 230 | 25 mm average thickness |
| 231 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 232 | Bars upto 12 mm diameter |
| 233 | Bars above 12 mm diameter |
| 234 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. |
| 235 | Upto and including 12mm dia. |
| 236 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 237 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 238 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 239 | 12 mm average thickness. |
| 240 | 25 mm average thickness in 2 layers. |
| 241 | Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness. Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete and appropriate approved Super- Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc. (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument) |
| 242 | 50mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 243 | 75mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 244 | Providing, erecting, maintaining and removing temporary protective screens made out of specified fabric with all necessary fixing arrangement to ensure that it remains in position for the work duration as required by the Engineer-in-charge. |
| 245 | Wooven PVC cloth |
| 246 | Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. |
| 247 | Replacementof sufficiently damaged reinforcements or providing additional reinforcements with the damaged reinforcement by welding etc. including cost of reinforcement(TMT bar of required dia) complete as per direction of the Engineer-in-charge.(Work is to be executed upto 50 m heights above G.L) |
| 248 | Plastering in cement mortar 1 : 3 (1 cement : 3 fine sand) of 12mm thick admixed with water proofing compound of approved make such as plastrocrate super or equivalent @ 0.2% weight of cement as per manufacture specification complete as per direction of Engineer-in-charge.(Work is to be executed upto 20 m heights above G.L) |
| 249 | Supply of Styles & rails for wooden door window shutters complete.( Payment to be made on area of new work only.) (i) 35 mm thick shutter (a)Local hard wood |
| 250 | Providing and fixing oxidised M. S. casement handle for steel window fastener with necessary screws etc. complete. |
| 251 | Providing and fixing fibre disk handle of 100 MM diametre fixed with aluminium screws complete as per the directions of Engr. In Charge . |
| 252 | Labour for taking out rolling shutter dismantling by parts for repair or (replacement of damaged parts only), rehanging and refitting the same in position after necessary repairs (excluding the cost of supply of new parts). |
| 253 | Renewing seam pipe for rolling shutter as per existing size and shape fitting, fixing complete. |
| 254 | Renewing side split pin for seam pipe for rolling shutter. |
| 255 | Oiling and greasing of rolling shutter and repair to in side lock. |
| 256 | Easing, oiling and cleaning collapsible gate |
| 257 | Renewing spring of rolling shutter as per existing size and shape including fitting fixing complete. |
| 258 | Supplying of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks,conforming to IS: 4454 -part 1 |
| 259 | 80x1.25mm M.S. laths |
| 260 | Supplying of approved make, made of required size guide with angle |
| 261 | Guide with angle-bracket |
| 262 | Renewing hinge of steel shutter including taking out old one by cutting and fixing new hinges by welding and mending good complete. |
| 263 | Renewing M.S Members of steel shutter by Welding including taking out old ,mending good damages complete, including taking out and refixing glass panes. |
| 264 | Labour fortaking out steel windows and refixing the same after replacement of damaged members, hinges etc. includingnecessary welding etc.Complete after carefully taking out existing glass panes (Payment for new members will be paid for separately). (a). For windows upto an area of 4.00 Square meter and upto floor V level |
| 265 | Supplying of MS steel window members for repairing of damaged steel window as per direction of the Engineer-in-Charge. |
| 266 | Easing, oiling and adjusting i/c scrapping or chiselling which ever is required as per site condition to steel window shutter and fitting so as to make the shutter easily operable for steel window as per direction of the Engineer-in-Charge. |
| 267 | Providing scaffolding of single layer with bamboo made of avg 75mm dia with adequate bracing, ties, ropes etc for strong durable and workablefor executing all items of work like replacement of sewarage/ R/W pipes & accessories, replacement of glass panes, uprooting/ cutting of tree, saplings, etc. includingprovision of steps for measurement purpose, making platformand proper maintanance of scaffolding to make it durable during entire period of works including removal of the same after completion of the work cleaning the site as per direction of Engineer in Charge. ( Projected area of scaffolding frame work on building elevation to be measured for payment) |
| 268 | Uprooting & removalwild growth & vegetation plants upto girth 100 mm on bldg at any level upto 15m by necessary scaoffolding and swing and providing and applying dilute Hydrochloric Acid on the root all complete as per direction of Engineer in Charge . |
| 269 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i)Single socketed pipes. |
| 270 | 160 mm diameter |
| 271 | Providing and fixing on wall face unplasticised Rigid PVC pipes of Supreme or equivalent conforming to IS : 13592 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 272 | 110 mm diameter |
| 273 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 274 | Plain Bend (i)160 mm diameter |
| 275 | Shoe (Plain) (i)160 mm diameter |
| 276 | DOOR Tee (i)160 mm |
| 277 | Bend 45° (i)110 mm bend |
| 278 | Door Bend(i)110 mm bend |
| 279 | Door Bend(ii)160 mm bend |
| 280 | Terminal Guard(i)75 mm |
| 281 | Terminal Guard(ii)110 mm |
| 282 | Terminal Guard(iii)160 mm |
| 283 | Elbow(i)75 mm |
| 284 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 285 | 160 mm diameter |
| 286 | Providing and making the jointsbetween PVC pipes & S.C.I./ C.I. Pipes with PVC coupler adhesive/ tapes etc. complete : 110/100 mm dia pipe |
| 287 | Taking out old damage terfelt from existing roof surface without damaging the roof slab and disposal of rubbish witin a lead of 50m and preparation of roof surface with 6mm thick cement morter at damage portion to receive new Tarfelt as per the direction of engineer in charge. |
| 288 | Removal of telephone cable, furniture and other garbage material stacked adjacent to Main TE building and which is making hinderance to external repair and painting at location shown by authority and as per direction of engineer in charge. |
| 289 | Credit Value for unserviceable material |
| 290 | Dismantled M.S. Materials |
| 291 | Steel Reinforcement |
| 292 | Dismantled G.I. Pipes upto 50 mm dia |
| 293 | Dismantled C.I. Pipes i/c accessories:Upto 150 mm |
| 294 | Aluminium |
| 295 | Wooden Partition |
| 296 | Steel Joist |
| 297 | Brick |