Tender For Renovation And Upgradation Work For Partial Portion Of Main Existing Building. - 1 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix) (As Per DSR- 15.2.1) 2 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead, Area 3 sq. metres and below (As Per DSR- 15.12.1) 3 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (As Per DSR- 15.56). 4 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (As per DSR- 15.3). 5 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (As per DSR- 15.7.4). 6 Demolishing mud phaska in terracing and disposal of material within 50 metres lead. (As Per D.S.R. - 15.27) 7 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. (As Per DSR- 1.1.18). 8 Brick work with F.P.S (non modular) bricks of class designation 12.5 in superstructure above plinth level up to floor five level in cement mortar 1:6 ( 1 cement : 6 coarse sand). (As per DSR- 6.3.1). 9 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1 :1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(As per DSR- 5.3) 10 Centering shuttering including strutting, propping etc. and removal of form work For Roof Beam (As per DSR- 5.9.5). 11 Centering shuttering including strutting, propping etc. and removal of form work For Slab (As per DSR- 5.9.3). 12 Steel Reinforcement For R.c.c Work Including Straighting , Cutting,Bending, Palcing in Position and Binding all Complete .Thermo-Mechanically Treated (TMT) bars of grade Fe-500D or more. (As per DSR- 5.22.6). 13 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (As Per DSR- 9.21.1). 14 Providing and fixing M.S. Tubular frames for doors windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1 :3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (As per DSR- 10.15.1) 15 Providing & fixing 4mm thk. glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with (As Per D.S.R. - 10.30.1) 16 Providing/fixing M.S. grills of required pattern in frames of windows etc. with M.S. flat, square or round bars etc. all complete (As per DSR- 9.48.1). 17 Providing & fixing of wire mesh (mosquito jalli) with labour & material comlete With 12 mm mild steel U beading.(As Per D.S.R. - 9.51.2) 18 Providing and fixing chromium plated brass handles with necessary screws etc. complete: 75mm,(As Per D.S.R. - 9.92.3) 19 Providing and fixing aluminium sliding door bolts, ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete (250x16 mm), (As per DSR- 9.96.2). 20 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete (100x10 mm), (As per DSR- 9.97.5). 21 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.(As Per D.S.R. - 9.101.1)(39.60) 22 Providing and fixing PTMT door catcher of length 72 mm and dia.of 42 mm with suitable washers weighing not less than 33 gms.(As Per D.S.R. - 9.109)(40.05) 23 Providing and laying in position cement concrete 1:4:8(1cement :4 coarse sand:08graded brick aggregated 40mm .nominal size.) excluding the cost of centering and shuttering - All work upto plinth level (As per DSR- 4.1.8). 24 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (As Per DSR- 11.41.2). 25 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Black Zebra. (As Per DSR No.- 11.23.4) (3001.20) 26 12mm thick plaster on the plain in side of mix 1:4 ( 1 cement : 4 coarse sand) mortar (As Per DSR- 13.4.1). 27 15mm thick Plaster on the rough in side of mix 1:4 ( 1 cement : 4 fine sand) mortar (As per DSR- 13.5.1). 28 6mm thick cementplaster of ceiling of mix 1:3 ( 1 cement : 3 fine sand) mortar (As Per D.S.R. - 13.16.1)(300.45) 29 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (As per DSR- 13.80). 30 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :on New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (As Per DSR- 13.41.1). 31 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:On New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (As Per DSR- 13.47.1). 32 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable sq.m shade with ordinary paint of approved brand and manufacture.(As Per DSR- 13.62.1). 33 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm andwall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. : 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. 34 Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineerin-Charge. (AS Per DSR- 22.22A). 35 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (110mm Dia) (AS Per DSR- 12.41.2). 36 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. (110mm Dia) (AS Per DSR- 12.43.2). 37 Providing and fixing white vitreous china laboratory sink with C.I.brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required Size 600x450x200 mm (As Per DSR- 17.11.2). 38 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (75mm) (As Per DSR- 12.41.1). 39 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (Coupler 75mm) (As per DSR- 12.42.1.1). 40 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (Coupler 75mm) (As per DSR- 12.42.1.2). 41 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (Single pushfit Coupler 75mm) (As per DSR- 12.42.2.1). 42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (Single pushfit Coupler 110mm) (As per DSR- 12.42.2.2). 43 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (Single tee with door 75mm) (As per DSR- 12.42.3.1). 44 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (Single tee with door 110mm) (As per DSR- 12.42.3.2. 45 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (Single tee without door75mm) (As per DSR- 12.42.4.1 46 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (Single tee without door110mm) (As per DSR- 12.42.3.2 47 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (Bend 87.5° , 75mm) (As per DSR- 12.42.5.1 48 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (Bend 87.5° , 110mm) (As per DSR- 12.42.5.2 49 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (Shoe (Plain), 110mm bend) (As per DSR- 12.42.6.2 50 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete (75mm) (As per DSR- 12.43.1 51 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete (110mm) (As per DSR- 12.43.2 52 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall (15mm dia nominal bore) (As per DSR- 18.7.1) 53 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall (25mm dia nominal bore) (As per DSR- 18.7.3) 54 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall (50mm dia nominal bore) (As per DSR- 18.7.6) 55 Providing and fixing ball valve (brass) of approved quality complete :-High or low pressure with plastic floats,25 mm dia. nominal bore (As per DSR- 18.18.1) 56 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore(As per DSR- 18.19.1) 57 Providing and fixing uplasticised PVC connection pipe with brass unions : 15mm nominal bore (As per DSR- 18.21.2.1) 58 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(As per DSR- 18.48) 59 Providing & Fixing C.P. brass bib cock parryware make (AS Per DSR-18.15.1) 60 Providing & Fixing C.P. brass Long bodybib cock (As per DSR- 18.51.1). 61 Providing & fixing c.p. soap dish parryware make (As per DSR- 18.65). 62 Provding & Fixing C.P Towel rail parryware make (As per DSR- 17.73.1). 63 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group A) (As Per DSR- 1.10.3) 64 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)(As Per DSR- 1.14.2). 65 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 4 sq. mm + 1 X 4 sq. mm earth wire)(As Per DSR- 1.14.3). 66 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.(20)(2 Pair) (As per DSR- 1.18.2). 67 Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (20mm (T.V+Telephone+Network) (As per DSR-1.21.1). 68 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (AS per DSR- 1.25). 69 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. [1 or 2 Module (75 mmX75 mm)] (AS per DSR- 1.27.1). 70 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. [3 Module (100 mmX75 mm)] (AS per DSR- 1.27.2). 71 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. [4 Module (125 mmX75 mm)] (AS per DSR- 1.27.3). 72 Supplying and fixing following Modular base & cover plate onexisting modular metal boxes etc. as required.(1 or 2 Module)As per DSR- 1.28.1). 73 Supplying and fixing following Modular base & cover plate onexisting modular metal boxes etc. as required.(3 Module)As per DSR- 1.28.2). 74 Supplying and fixing following Modular base & cover plate onexisting modular metal boxes etc. as required.(4 Module)As per DSR- 1.28.3). 75 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.(As per DSR- 1.33). 76 Supplying and flxing brass batten/angle holder including connection etc. as required. (As per DSR- 1.34). 77 Installation, testing and commissioning of wall bracket /ceilingfittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories includingconnections etc. as required. (As per DSR- 1.35). 78 Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required.(As per DSR- 1.39). 79 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. (As PEr DSR-1.41). 80 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.(1 run of cable) (As per DSr- 1.53.1). 81 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.(2 run of cable) (As per DSr- 1.53.2). 82 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.(3 run of cable) (As per DSr- 1.53.3). 83 Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)(4 way (4 + 12), Double door)(As per DSR- 2.5.1). 84 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole) (AS per DSR- 2.10.1). 85 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(40 amps)(As per DSR- 2.13.1). 86 Providing and fixing M.V. danger notice plate of 200 mm X 150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.(As per DSr- 2.21). 87 Supply of AC 230/250 volts, 50 HZ energy efficient Ceiling fan with standard down rod, blades, 2 nos. caps etc. complete(1200 mm Sweep) (As per DSR-19.1). 88 Supply and fixing of LED Tube Light with batten suitable for up to 1 x 22 watt LED tube light fitting including tube on surface complete in all respect. (CAT- AA) (philips 22 w) (AS per PWD SOR- 1413). 89 Supply of LT XLPE PVC aluminium Unarmoured cable 50 Sq.mm 4core 1100 volt. (As per DSR-19.1.36). 90 Supply of LT XLPE PVC aluminium Unarmoured cable 150 Sq.mm 3.5core 1100 volt.(As per DSR-19.1.26).