| 1 | Supply Portion |
| 2 | Installation of New Distribution Tansformer 25KVA (203 Nos) |
| 3 | 9m Steel Tubular poles (410 SP-31) - (embossing as per design drawing of MSPDCL) |
| 4 | Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for supporting Transformer |
| 5 | Galvanised Clamp for transformer base channel for M.S. flat [email protected]/m 0.27mX2. |
| 6 | Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for D.P. X-arm |
| 7 | Galvanised Channel 100X50,@7.9 Kg/m 0.46X2 for supporting of item 2 |
| 8 | Galvanised Channel 75X40,@5.7Kg/m 2.8X2m for HG fuse unit & A.B. switch |
| 9 | Galvanised Clamp for A.B. switch/HG Fuse/DO Fuse, 50X8mm @ 3.1Kg/m 0.23mX2=0.46m. |
| 10 | Galvanised Channel 75X40,@5.7Kg/m 0.5X2m for supporting H.G. fuse main channel X-arm |
| 11 | Galvanised Angle (50X50X6)mm 2.8X2 @ 4.5 Kg/m transformer belting and Angle (35X35X5),0.46X2 @ 2.6 Kg/m. Transformer belting support. |
| 12 | Galvanised Clamp for transformer belting |
| 13 | Distribution transformer 25 KVAEfficiency level -II(2 star) Amendment No. 4 |
| 14 | A.B.Switch (Set of 3) |
| 15 | Horn gap fuse unit/D.O. fuse, 3 -Ph (Set of 3) |
| 16 | DTR Cubicle for DTRs (Comprising of requisiteand adequate ratings ofMCCBs/MCBsfor LT protection in incomer and outgoing along with accessories required. |
| 17 | 1.1KV grade, 31/2 core 120 Sq.mm XLPE insulated cable |
| 18 | Galvanised D.B.box cross arm of M.S. Angle 35X35X5mm @ 2.6Kg/m 2.8X2 = 5.6m |
| 19 | Galvanised Clamp for DB Box Cross arm |
| 20 | Sub-Station Earthing (Set of 3 Earthing Pipe) |
| 21 | Danger Plate |
| 22 | 11 KV lightening arrestor |
| 23 | Nuts & Bolts with washers ((5/8)\" X 3\" / 6.5\" / 8.5\" ) |
| 24 | Installation of New Distribution Tansformer 63KVA (48 Nos) |
| 25 | 9m Steel Tubular poles (410 SP-31) - (embossing as per design drawing of MSPDCL) |
| 26 | Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for supporting Transformer |
| 27 | Galvanised Clamp for transformer base channel for M.S. flat [email protected]/m 0.27mX2. |
| 28 | Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for D.P. X-arm |
| 29 | Galvanised Channel 100X50,@7.9 Kg/m 0.46X2 for supporting of item 2 |
| 30 | Galvanised Channel 75X40,@5.7Kg/m 2.8X2m for HG fuse unit & A.B. switch |
| 31 | Galvanised Clamp for A.B. switch/HG Fuse/DO Fuse, 50X8mm @ 3.1Kg/m 0.23mX2=0.46m. |
| 32 | Galvanised Channel 75X40,@5.7Kg/m 0.5X2m for supporting H.G. fuse main channel X-arm |
| 33 | Galvanised Angle (50X50X6)mm 2.8X2 @ 4.5 Kg/m transformer belting and Angle (35X35X5),0.46X2 @ 2.6 Kg/m. Transformer belting support. |
| 34 | Galvanised Clamp for transformer belting |
| 35 | Distribution transformer 63 KVAEfficiency level -II(2 star) Amendment No. 4 |
| 36 | A.B.Switch (Set of 3) |
| 37 | Horn gap fuse unit/D.O. fuse, 3 -Ph (Set of 3) |
| 38 | DTR Cubicle for DTRs (Comprising of requisiteand adequate ratings ofMCCBs/MCBsfor LT protection in incomer and outgoing along with accessories required. |
| 39 | 1.1KV grade, 31/2 core 120 Sq.mm XLPE insulated cable |
| 40 | Galvanised D.B.box cross arm of M.S. Angle 35X35X5mm @ 2.6Kg/m 2.8X2 = 5.6m |
| 41 | Galvanised Clamp for DB Box Cross arm |
| 42 | Sub-Station Earthing (Set of 3 Earthing Pipe) |
| 43 | Danger Plate |
| 44 | 11 KV lightening arrestor |
| 45 | Nuts & Bolts with washers ((5/8)\" X 3\" / 6.5\" / 8.5\" ) |
| 46 | Installation of New Distribution Tansformer 100 KVA (9 Nos) |
| 47 | 9m Steel Tubular poles (410 SP-31) - (embossing as per design drawing of MSPDCL) |
| 48 | Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for supporting Transformer |
| 49 | Galvanised Clamp for transformer base channel for M.S. flat [email protected]/m 0.27mX2. |
| 50 | Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for D.P. X-arm |
| 51 | Galvanised Channel 100X50,@7.9 Kg/m 0.46X2 for supporting of item 2 |
| 52 | Galvanised Channel 75X40,@5.7Kg/m 2.8X2m for HG fuse unit & A.B. switch |
| 53 | Galvanised Clamp for A.B. switch/HG Fuse/DO Fuse, 50X8mm @ 3.1Kg/m 0.23mX2=0.46m. |
| 54 | Galvanised Channel 75X40,@5.7Kg/m 0.5X2m for supporting H.G. fuse main channel X-arm |
| 55 | Galvanised Angle (50X50X6)mm 2.8X2 @ 4.5 Kg/m transformer belting and Angle (35X35X5),0.46X2 @ 2.6 Kg/m. Transformer belting support. |
| 56 | Galvanised Clamp for transformer belting |
| 57 | Distribution transformer 100 KVAEfficiency level -II(2 star) Amendment No. 4 |
| 58 | A.B.Switch (Set of 3) |
| 59 | Horn gap fuse unit/D.O. fuse, 3 -Ph (Set of 3) |
| 60 | DTR Cubicle for DTRs (Comprising of requisiteand adequate ratings ofMCCBs/MCBsfor LT protection in incomer and outgoing along with accessories required. |
| 61 | 1.1KV grade, 31/2 core 120 Sq.mm XLPE insulated cable |
| 62 | Galvanised D.B.box cross arm of M.S. Angle 35X35X5mm @ 2.6Kg/m 2.8X2 = 5.6m |
| 63 | Galvanised Clamp for DB Box Cross arm |
| 64 | Sub-Station Earthing (Set of 3 Earthing Pipe) |
| 65 | Danger Plate |
| 66 | 11 KV lightening arrestor |
| 67 | Nuts & Bolts with washers ((5/8)\" X 3\" / 6.5\" / 8.5\" ) |
| 68 | New 11 KV line using ACSR Rabbit (239.05 km) |
| 69 | 9m Steel Tubular poles (410 SP-31) - (embossing as per design drawing of MSPDCL) |
| 70 | Galvanised Pole top bracket |
| 71 | Galvanised Clamp for Pole top Bracket |
| 72 | Galvanised Cross arm(75X40)mm |
| 73 | Galvanised Back clamp for X-arm |
| 74 | Galvanised 2.2m D.P. channel X-arm (75X40)mm |
| 75 | 11 KV Disc. Composite/Polymer Insulator (Complete set i/c Tension clamps,Hardware) |
| 76 | 11 KV Pin Composite/Polymer Insulator (Complete with Pin) |
| 77 | ACSR Conductor (Rabbit) |
| 78 | Stay Set complete with stay wire, base plate, stay rod etc. |
| 79 | Galvanised Stay Clamp |
| 80 | Galvanised Bracing for D.P.structure, 50X50X6mm M.S. Angle |
| 81 | Galvanised Clamp for D.P. Bracing |
| 82 | Galvanised Anti climbing device complete |
| 83 | Earthing set complete with G.I. wire |
| 84 | Guarding at crossing with G.I. wire |
| 85 | Bolts & Nuts with washer (5/8X3\"/6.5\") |
| 86 | Al. Binding wire, UPG clamps etc. |
| 87 | Danger Plate |
| 88 | Number Plate |
| 89 | New LT line using 3 Phase 4 wire with AB Cable (3X50+1X35) Sq.mm (209.1 km) |
| 90 | 8m Steel Tubular poles (410 SP-14) - (embossing as per design drawing of MSPDCL) |
| 91 | M.S. cross arm (75X40) mm, 500 mm long |
| 92 | Back clamp for cross arm |
| 93 | Dead end fittings for AB Cable with bare messenger wire complete with Eye hook as per Construction Standards : |
| 94 | Suspension fittings for AB Cable with bare messenger wire complete with Eye hook as per Construction Standards : |
| 95 | AB Cable (3x50+1x35)Sq.mm |
| 96 | Insulation piercing connector suitable for AB Cable Big Size (Main: 16-95 sq.mm, Service: 4-35 (50) sq.mm) (2 Pieces per Set) |
| 97 | Earthing set complete with G.I. wire |
| 98 | Stay set complete with stay wire and insulator clamp etc. |
| 99 | Bolts & Nuts with washer (5/8X3\" full thread) |
| 100 | Danger Plate |
| 101 | Number Plate |
| 102 | New LT line using 3 Phase 4 wire with AB Cable (3X35+1X25) Sq.mm (257.55 km) |
| 103 | 8m Steel Tubular poles (410 SP-14) - (embossing as per design drawing of MSPDCL) |
| 104 | Galvanised M.S. cross arm (75X40) mm, 510 mm long |
| 105 | Galvanised Back clamp for cross arm |
| 106 | Dead end fittings for AB Cable with bare messenger wire complete with Eye hook as per Construction Standards : |
| 107 | Suspension fittings for AB Cable with bare messenger wire complete with Eye hook as per Construction Standards : |
| 108 | AB Cable (1x35+1x25)Sq.mm |
| 109 | Insulation piercing connector suitable for AB Cable Big Size (Main: 16-95 sq.mm, Service: 4-35 (50) sq.mm) (2 Pieces per Set) |
| 110 | Earthing set complete with G.I. wire |
| 111 | Stay set complete with stay wire and insulator clamp etc. |
| 112 | Bolts & Nuts with washer (5/8X3\" full thread) |
| 113 | Danger Plate |
| 114 | Number Plate |
| 115 | Service Connection to Un-electrified households |
| 116 | PVC Insulated Twin Core (unarmoured) cable 4sqmm Cable |
| 117 | 16 A Double Pole MCB |