Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-02-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-02-2025 |
| Sl. No. | Item Description |
| 1 | PART - A (BALANCE CIVIL WORKS)Earthwork Excavation by mechanical means (Hydraulic excavator) / manual means in all Sorts of Soil for plinth and foundation, trenches and other miscelleneous works up to an average depth of 1.5 meters including shoring, strutting, bailing out water if necessary, leveling, hand ramming the bottom of trenches with proper watering, refilling the sides of foundation / trenches up to the existing ground level with excavated available good quality of Soil in layers; not exeeding 150 mm thick [each layer] with leveling; dressing; & ramming properly the each layer with watering and disposing the surplus earth / unwanted materials materials within a lead of 50 meters etc. complete all as per specifications, as per drawing and as directed Engineer-in-charge. |
| 2 | All kinds of soil - Upto 1.5mtr depth |
| 3 | PART - A (BALANCE CIVIL WORKS)Providing Pre-Construction Anti Termite Treatment by treating contact surface of soil with the plinth beams, top surface of plinth filling & plinth protection area etc. as per IS:6313 with a performance guarantee of five years etc. complete all as per specifications and as directed Engineer-in-charge.Note: measurement shall be for plinth area of the building. |
| 4 | PART - A (BALANCE CIVIL WORKS)Filling in plinth by soil including spreading in layers, watering, consolidating to 200mm thickness and finished to the desired level etc. complete as per specifications, relevant IS and as directed by Engineer-in-Charge. |
| 5 | Using selected excavated earth |
| 6 | PART - A (BALANCE CIVIL WORKS)Providing and laying Rubble Stone Soling using hard granite stones below floor, for consolidated thickness of 150mm with stones vertically hand set, interstices packed with smaller stone chips, binding with murrum, watering, consolidating and finish to level etc. complete as per specifications and as directed by Engineerin- Charge. |
| 7 | PART - A (BALANCE CIVIL WORKS)Providing and laying in proportion P.C.C1:3:6Plain cement concrete using 20mm down crushed aggregate of approved quality for mudmatleveling course for foundation, plinth and below flooring including form work wherever necessary, consolidation, leveling, finishing and curing etc complete as per specification and as directed by Engineer-in-Charge. |
| 8 | PART - A (BALANCE CIVIL WORKS)Providing and laying PCC 1:2:4 using 20 mm & downsize, clean, crushed, well graded, cubical shape, sharp edged aggregates of hard, durable & approved quality stones / rubbles for plinth, floor & drain bedding & all other various miscellaneous PCC works including machine mixing, transporting, laying, spreading, consolidating, levelling, finishing as directed, providing; fixing & removing necessary form work; as & when required / directed, preparation of base properly by dressing; levelling & hand ramming using wooden hand rammer by proper watering, racking out all the masonry joints & close hacking the old / new concrete / plastered surfaces for proper / good bonding, base shall be fully neat, clean & slightly wet before laying Concrete, Curing for a minimum period of 7 days, cleaning the work area & disposing the debris / waste materials / unwanted materials / things etc., upto a lead of 2000 meters outside the pheriphery of work premises etc. complete all as per specification and as directed by the Engineer-in-charge at all locations and at all lifts / heights. |
| 9 | PART - A (BALANCE CIVIL WORKS)Providing and Constructing R.R. masonry, using hard; durable & approved quality stones / rubbles, in CM 1:6 for foundation works & all other miscellaneous RR masonry works etc., including racking out all the masonry joints or simultaneous flush pointing, providing; fixing & removing necessary staging / platform wherever; as & when required / directed, close hacking the old / new concrete / plastered surfaces forproper / good bonding, base shall be fully neat, clean & slightly wet before laying masonry, Curing for a minimum period of 7 days, cleaning the work area & disposing the debris / waste materials / unwantedmaterials / things etc., upto a lead of 2000 meters outside the pheriphery of work premises etc. complete all as per specification and as directed by the Engineer-in-charge at all locations and at all lifts / heights. |
| 10 | PART - A (BALANCE CIVIL WORKS)Providing and laying Cast Insitu RCC of M 30 grade using graded stone aggregate 20mm max size including weigh batching, mechanical mixing, transporting and placing, vibrating, consolidation, finishing, curing,etc complete atforcloumn, beams slab, stair case for all RCC worksall heights/ levels as per drawing, specifications and as directed, but excluding formwork and steel reinforcement. |
| 11 | Up to 5th Floor |
| 12 | 5th Floor to Terrace Level |
| 13 | PART - A (BALANCE CIVIL WORKS)Providing centering and shuttering for all RCC works including removal of the same for in-situ reinforced concrete using approved formwork including sturting propping etc at all levels, heights & floors and removal of the same for in-situ reinforced concrete. Complete as per specifications, relevant IS and as directed by Engineer-in-Charge. |
| 14 | up to 5th Floor to Terrace LevelBeams, Lintels ,Slab, stair case etc., |
| 15 | 6th Floor to Terrace LevelCloumn, walls |
| 16 | 6th Floor to Terrace LevelBeams, Lintels ,Slab, stair case etc., |
| 17 | PART - A (BALANCE CIVIL WORKS)Providing and placing in position Reinforcement of all diameters confirming to grade Fe 415, IS:1786-2008 for reinforced cement concrete for all Heights/levels including supplying, cutting, bending, fixing, tying in position with 16 gauge soft drawn annealed binding wire with chair supports, spacer bars etc. complete including cost of transporting, straightening and binding wire, cost of cover block in cement concrete M-25 / M-30 grade as per specification etc. complete. |
| 18 | PART - A (BALANCE CIVIL WORKS)Providing & Constructing 200 mm AAC using Light weight CC Blocks of standard & of approved size& confirming to the relevant BIS of the latest edition, for Main wall and all other miscellaneous Masonry worksincluding removing necessary staging / platform wherever; as & when required / directed, racking out properly all the masonry joints, close hacking properly the old / new concrete surfaces & other plaster surfaces for proper / good bonding, base shall be fully neat, clean & slightly wet before laying masonry, Curing for a minimum period of 7 days, cleaning the work area & disposing the debris / waste materials / unwanted materials / things etc., upto a lead of 2000 meters outside the pheriphery of work premises etc. complete all as per specification and as directed by the Engineer-in-charge at all locations and at all lifts / heights. |
| 19 | Up to 5th Floor |
| 20 | 6th Floor to Terrace Level |
| 21 | PART - A (BALANCE CIVIL WORKS)Providing & Constructing 100 mm thick Concrete Block Masonry using AACBlocks of standard & of approved size,& confirming to the relevant BIS of the latest edition in CM 1:4 including providing & laying 2 numbers of 6 mm dia reinforcemnt steel bars [conforming to the BIS 1786, FE - 415 / 500] at every fourth layer. Note: Providing & laying Reinforcement Steel will be measured & paid under item No. |
| 22 | Up to 5th Floor |
| 23 | 6th Floor to Terrace Level |
| 24 | PART - A (BALANCE CIVIL WORKS)Providing cement plaster 12mm thick to underside of all concrete surfaces such as ceiling, chejjas, stair case etc., at all floor and heights in CM 1:4 rubbed perfectly so as to obtain smooth and even finish including close hacking of concrete surface, scaffolding, curing etc., complete all as per specifications and as directedby the Engineer in-charge. |
| 25 | PART - A (BALANCE CIVIL WORKS)Providing and laying cement plaster 15mm thick for internal surfaces of walls and columns at all Floor and heights in CM 1:4, rubbed perfectly so as to obtain smooth and even finish including close hacking of concrete surface wherever required, scaffolding, curing etc. complete as per specification and as directed by the Engineer in-charge. |
| 26 | PART - A (BALANCE CIVIL WORKS)Rendering smooth finish; using Brila White Putty in Two Coats over internal plastered surfaces of wall; concrete & ceiling including rubbed perfectly so as to obtain smooth & even finish, providing; fixing & removing necessary staging / platform, preparation of base properly by cleaning & washing, Base shall be fully neat, clean & drybefore application of putty, cleaning the work area & disposing the debris / waste materials / unwanted materials / things etc., upto a lead of 2000 meters outside the pheriphery of work premises etc. complete all as per specification and as directed by the Engineer-in-charge at all locations and at all lifts / heights. |
| 27 | PART - A (BALANCE CIVIL WORKS)Providing and laying cement plaster 18 mm thick in two coats for external surfaces at all heights with cement mortar 1:5 back coat of 12mm thick and 1:3 finishing coat of 6 mm thick with water proofing compound at the rate of 2% by weight of cement or as per manufacturer\"s specification, finishing smooth including hacking concrete surfaces, scaffolding, curing and providing necessary Architectural finishes like grooves, dripmoulds, cornices, mouldings, columns grooves etc., and shall be matched with the existing plastered surfaces complete as per specifications as directed by the Engineer. |
| 28 | PART - A (BALANCE CIVIL WORKS)Providing and laying in position cement concrete flooring 40mm thick with metallic concrete hardener toping, under layer of 28mm thick 1:2:4 cement concrete using broken granite metal of 20mm down size and a top layer 12mm thick of metallic cement hardener consisting of mix 1:2 using 10mm down size aggregates, with metallic hardening compound of approved quality mix in ratio of 4:1 (4 part of cement and 1 part of metallic floor hardening compound) laid to proper line, level and slope in alternate bays including compaction, filling joints marking lines to give appearance of tiles 30cm x 30cm or other approved design, finishing smooth (with extra cement) in approved colouretc complete as per specification and directed by the Engineer In-charge. |
| 29 | PART - A (BALANCE CIVIL WORKS)Providing and laying Vitrified Tilesofapproved make, approved shade / colour & thickness of tile shall be 9 mm to 10 mm for Flooring with 20 mm thick CM of 1:4 [bedding] and for Skirting with 12 mm thick CM of 1:3 [backing] or using approved Adhesive [for Flooring & Skilting] pasting the Vitrified tiles on concrete or on masonry or on plastered surfaces, close jointed [with or without spacers] as directed, grout filling in the joints with matching pigmented cement slurry, finished to true line & levels / slope / plumb etc., including cutting of tiles, recommended washing, preparation of base by close hacking / roughening of existingbase, racking out all the adjoining masonry joints, cleaning & washing the base with clean water, base should be fully neat; clean & slightly wet / moist before laying mortar & tiles and base shall be fully neat; clean & dry before laying adhesive & tiles, cleaning & washing / mopping the work area and disposing the debris / unwanted materials up to a lead of 2000 meters outside the periphery of work premises etc., complete all as per specifications, as per manufacturers specification and as directed by the Engineer-in-charge at all locations & at all lifts / heights. (Basic rate of material shall be minimum Rs. 45/- per Sq.ft) |
| 30 | Flooring |
| 31 | Skirting |
| 32 | PART - A (BALANCE CIVIL WORKS)Providing and laying Antiskid Ceramic Tiles of605 mm X 605 mm or of any other approved size and make of approved shade / colourthickness of tile shall be 8 mm to 8.9 mm for Flooring with 20 mm thick CM of 1:4 [bedding] and for Skirting with 12 mm thick CM of 1:3 [backing] or using approved Adhesive [for Flooring & Skilting] pasting the Vitrified tiles on concrete or on masonry or on plastered surfaces, close jointed [with or without spacers] as directed, grout filling in the joints with matching pigmented cement slurry, finished to true line & levels / slope / plumb etc., including cutting of tiles, recommended washing, preparation of base by close hacking / roughening of existingbase, racking out all the adjoining masonry joints, cleaning & washing the base with clean water, base should be fully neat; clean & slightly wet / moist before laying mortar & tiles and base shall be fully neat; clean & dry before laying adhesive & tiles, cleaning & washing / mopping the work area and disposing the debris / unwanted materials up to a lead of 2000 meters outside the periphery of work premises etc., complete all as per specifications, as per manufacturers specification and as directed by the Engineer-in-charge at all locations & at all lifts / heights. ( Basic rate of material shall be minimum Rs. 45/- per Sq.ft) |
| 33 | Flooring |
| 34 | Skirting |
| 35 | PART - A (BALANCE CIVIL WORKS)Providing and laying Antiskid ceramic tiles for flooring using tiles of approved make, shade/ colour and of 300 x 300 mm size having minimum thickness of 6 mm in approved pattern over a bed of 12mm thick in cement mortar 1:3, close jointed and pointed with matching pigmented cement slurry and finished to line/ levels as required including cutting of tiles, curing, acid washing etc. complete all as per specification, as per drawing and as directed by engineer-in-charge at all floors and heights.[Basic rate of material shall be minimum Rs. 35/- per Sq.ft] |
| 36 | PART - A (BALANCE CIVIL WORKS)Providing and laying ceramic tiles for dado/ skirting using tiles of approved make, shade/ colour and of 300 x 450 mm size having minimum thickness of 5.5mm in approved pattern over a bed of 12mm thick in cement mortar 1:3, close jointed and pointed with matching pigmented cement slurry and finished to line/ levels as required including cutting of tiles, curing, acid washing etc. complete all as per specification, as per drawing and as directed by engineer-in-charge at all floors and heights.[Basic rate of material shall be minimum Rs. 35/- per Sq.ft] |
| 37 | PART - A (BALANCE CIVIL WORKS)Providing and laying 20mm thick Kota stonefor Staircasetreads and landing at all heights using machine cut slabs in single piece or as directed over a bed of 12mm thick in cement mortar 1:3, close jointed and pointed with matching pigmented cement slurry including rounding off the nosing, curing , polishing etc. complete all as per specification, as per drawing and as directed by engineer-in-charge at all floors and heights. |
| 38 | PART - A (BALANCE CIVIL WORKS)Providing and laying 18 to 20 mm thick Black Granitestone of approved colour & shade for Kitchen Platform & Facia using machine cut pre-polished on one face, slabs in single piece or as directed laid over 20mm thick cement morter 1:4, close jointed and pointed with matching pigmented cement slurry finished to levels, slope as required & curing, rubbing, nosing rounded off etc. complete as per specifications and as directed by the Engineer in-charge. |
| 39 | PART - A (BALANCE CIVIL WORKS)Providing and laying 25 mm thick Cuddappa Slabs of approved colour & shade for Kitchen Store & Below Platformusing machine cut pre-polished on one face, slabs in single piece or as directed laid over 20mm thick cement morter 1:3, close jointed and pointed with matching pigmented cement slurry finished to levels, slope as required & curing, rubbing, nosing rounded off etc. complete as per specifications and as directed by the Engineer in-charge. |
| 40 | PART - A (BALANCE CIVIL WORKS)Providing and laying 18 to 20 mm thick Marble stone of approved colour & shade for Basin counter top, window sills,wardrobe shelves etc., using machine cut pre-polished on one face, slabs in single piece or as directed, close jointed and pointed with matching pigmented cement slurry finished to levels, slope as required & curing, rubbing, nosing rounded off etc. complete as per specifications and as directed by the Engineer in-charge. |
| 41 | PART - A (BALANCE CIVIL WORKS)Supplying and fabrication work |
| 42 | M.S structural steel work like Gates, access ladders, window grills, anchor bolts, handrail other misc. steel works including transporting, erecting, site welding/ bolting, grouting, leveling, aligning and fixing in position and including providing a coat of zinc phosphate primer and two coats of high gloss synthetic enamel paint of approved brand& colour as per specifications, detailed scope of work and as directed. |
| 43 | 50mm dia SS Hand Rail |
| 44 | PART - A (BALANCE CIVIL WORKS)Providing and fixing in position of following door frame and shutters, including fixture as per the drawing enclosed etc., complete. |
| 45 | DOOR TYPE - MD - size 1000x 2100 |
| 46 | DOOR TYPE - D1 - size 1000x 2100 |
| 47 | DOOR TYPE - D2- size 9000x 2100 |
| 48 | DOOR TYPE - D3 -size 750x 2100 |
| 49 | DOOR TYPE - D4 - size 750x 2100 |
| 50 | DOOR TYPE - D5 - size 300x1200 |
| 51 | DOOR TYPE - SD1 -size 1500x2100 |
| 52 | DOOR TYPE - FD - size 1000x1200 |
| 53 | DOOR TYPE - HD -.size 600x1200 |
| 54 | DOOR TYPE - FG - .size 600x1200 |
| 55 | PART - A (BALANCE CIVIL WORKS)Providing and fixing in position of following Pre-painted Galvanised Window frame and shutters, including fixture as per the enclosed drawing. |
| 56 | W1 - Size: 1800 x 1400mm |
| 57 | W2 - Size: 1800 x 1400mm |
| 58 | W3 - Size: 1200 x 1400mm |
| 59 | W4 - Size: 1500 x 1400mm |
| 60 | KW - Size: 750 x 1400mm |
| 61 | V1 - Size: 600 x 600mm |
| 62 | V2 - Size: 2000 x 600mm |
| 63 | PART - A (BALANCE CIVIL WORKS)Providing and fixing Second quality teak wood work for wardrobe frame, pelmets, etc., with suitable hold fast or Anchor fastener including providing & applying two or more coat of Synthetic Enamel Paint on exposed surfaces etc., complete. |
| 64 | PART - A (BALANCE CIVIL WORKS)Providing and fixing Wardrobe Shuttersusing 19 mm thick water proof plywood with 12 mm thick teak wood lipping alround exposed surface ,0.5mm thick laminate on external surfaces and one coat of primer and two coats of enamel paint on internal surfaces. The each shutter shall be provided with hardware fixtures like 125mm grip SS Door handles, 3 nos of SS Hinges, multipurpose locks of approved make etc., complete |
| 65 | PART - A (BALANCE CIVIL WORKS)Providing and fixing Wooden Pelmet 18mm thick water proof plywood with 12 mm thick teak wood lipping alround exposed surface ,0.5mm thick laminate onboth external surfaces , SS 150mm size Door hanles, 3 x 2 nos of SS Hinges, multipurpose locks of approved make etc., complete |
| 66 | PART - A (BALANCE CIVIL WORKS)Providing and laying Integral Water Proofing Treatment to the inside surface ofsunken floors, chejja, walls by applying Two Coats of Polymer Modified Cementious Coatings of approved make including well finishing with Cement Mortar 20 mm thick in CM 1:4, cleaning & washing, base shall be fully neat, clean & dry before application of Polymer Modified Cementious Coatings and base shall be fully neat, clean & slightly wet before taking plastering work, providing, fixing & removing necessary staging / platform wherever; as & when directed / required, curing for a minimum period of 7 days, cleaning the work area & disposing the debris / waste / unwanted materials upto a lead of 2000 meters outside the periphery of the work premises etc. complete all as per specification, as per manufacturers specification and as directed by the Engineer-in-charge at all lifts / heights & at all locations.Note:Measurement for payment shall be actual area covered by the treatment. |
| 67 | PART - A (BALANCE CIVIL WORKS)Providing and layingIntegral Cement Based Water Proofing Treatment with Brunt Brick Bat Cobaover Roof Slab using well Brunt Brick Bats of size 25 mm to 115 mm, OPC Cement mixed with water proofing compound [confirming to the BIS 2645 of the latest edition] @ rate of 2 % by the weight of cement or as per the manufacturers specification] and thin Fibre Glass Cloth [of approved brand, quality, fexible uniformaly bonded mat composed of chemically resistant borosilicate glass fibre distributed in random open porous structure bonded togather with a thermosetting resin]including preparation of base by roughening the base and the base shall berough; neat; clean [free from oil; grease; dust; dirt; fungus; algae; dead / waste mortar or concrete debris and washed using clean water] & slightly wet before executing the each stages of Integral Cement Based Water Proofing Treatment etc complete as per technical specifications. |
| 68 | PART - A (BALANCE CIVIL WORKS)Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications as per manufacturers specification and as directed by Engineer-in-charge at all locations and at all lifts/heights. |
| 69 | PART - A (BALANCE CIVIL WORKS)Providing one coat of approvedprimer and two coats of Oilbound distemper paintof approved shade and make including preparation of surface, rubbing with sand paper, cleaning, etc., for internal wall, concrete surfaces and ceiling as mentioned in drawings, providing and removing necessary scaffolding etc. complete as per the specification and as directed by the Engineer In-charge at all heights. |
| 70 | PART - A (BALANCE CIVIL WORKS)Providing one coat of approvedprimer and two coats of Plastic emulsion paint (matt finish) of approved shade and make including preparation of surface, rubbing with sand paper, cleaning, etc., for internal wall, concrete surfaces and ceiling as mentioned in drawings, providing and removing necessary scaffolding etc. complete as per the specification and as directed by the Engineer In-charge at all heights. |
| 71 | PART - A (BALANCE CIVIL WORKS)Providing and painting of texured paint spectrum or equivalentbrand as per maunfacturers recommendations including surface preparations and application of putty, necessary scaffolding etc.complete as directed. |
| 72 | PART - A (BALANCE CIVIL WORKS)Providing and applying one coat of approved primer and two or more coats of weatherproof exterior acrylic emulsion paint of approved make and shade to give an even shade for all exterior wall and concrete surfaces including preparation of surface, application of putty, rubbing with sand paper, providing and removing scaffolding, curing etc., complete as per the specification and as directed by the Engineer In-charge at all heights. |
| 73 | PART - A (BALANCE CIVIL WORKS)Supplying heavy gauge PVCConduit Pipe....dia.......mm thick with suitable sizebends, metal junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing UorJ hooks and cement plastering upto the wall surface and run with18SWG GI fishwire run throughout the conduit wherever necessary. |
| 74 | 19/20 mm dia 2 mm thick |
| 75 | 25 mm dia 2 mm thick |
| 76 | PART - A (BALANCE CIVIL WORKS)Supplying and fixing sheetMetal box made out of18SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. |
| 77 | 75 x 75 x 65 mm |
| 78 | 100 x 75 x 65 mm |
| 79 | 135 x 75 x 65 mm |
| 80 | 180 x 90 x 65 mm |
| 81 | 200 x 90 x 65 mm |
| 82 | PART - A (BALANCE CIVIL WORKS)Supplying And Fixing Metal Fan Box with Round Hook. |
| 83 | PART - A (BALANCE CIVIL WORKS)Providing andlaying / fixing CPVC Pipes & its required Fittings[Pipes & Fittings shall be of plumbing quality ofapproved brand/ Make and confirming to the IS:15778 Schedule D - 80 specification of the latest edition] including providing & fixingfittings like collars, elbows, tees, unions, coupling, reducers, enlargers, bends, nipples and all other fittings required for completing the job, as per code of practice for water supply to the buildings [BIS 2065ofthe latest edition], fixing on thewall surfaceof the building with suitable clamps, jointing the pipes & fittings using CPVC solventcost of all materials like white or red lead, clamps, cement, sand, tools & takles, testing the pipe with clean water as per specifications and ensuring smooth functioning, providing; fixing & removing necessary staging / platformcleaning & washing / mopping the work area, disposing off waste materials / debris etc., complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-in-charge at all locations & at all lifts.( Internal ( concealed)Piping works) |
| 84 | 20mm dia |
| 85 | 25mm dia |
| 86 | 32mm dia |
| 87 | PART - A (BALANCE CIVIL WORKS)Providing, laying,jointing, fixing and testing of approved sewage quality SWR UPVC pipes including fitting like collars,elbow,Tees,Unions,Couplings,Reducers,Enlargers,bBends,Nipples and all other fittings required for completion as per the code of practice of water supply to Buildings(IS 2065 latest edition) including laying under the floors,chasing in walls,roof slab including concealing in walls and floors wherever required and making goodthe same to the original conditions including cost of all materials like PVC solvets,clamps,wooden gutties,screws,cement sand etc including testing the pipe with clean water as per specifications etc.complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-in-charge at all locations & at all lifts. |
| 88 | 75mm dia (4kg / sq.cm) |
| 89 | 110mm dia (4 kg / sq.cm) |
| 90 | PART - A (BALANCE CIVIL WORKS)Providing and fixing PVC heavy duty Nahani Trap (SWR Fittings IS:14735)[floor trap]100X75mmof self cleaning design with 75 mm. outlet having a minimum water seal of 50 mm of Approved Brand / make with PVC grating of 125 mm dia [of approved quality & make], finishing neatly, curing, ensuring smooth functioning, including labour charges, required tools & tackles,& consumables, Cleaning & washing / mopping,the work area, disposing off waste materials / debris etc., upto a lead of 100 Mts outside the periphery of work premises etc., complete all as per specification and as directed by the Engineer-in-charge at all locations & at all lifts. |
| 91 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixingwhite vitreous china clay Water closet European type (Pedistal type \"P\" trap) with white solid plastic seat and lid, C.P brass hinges, rubber buffer [confirming to the relevant BIS specification of the latest edition]with all jointing materials, including necessary making hole in masonry & making good the same,cleaning & washing the work area with clean water and disposing the debris / unwanted materials etc., complete all as per specifications, |
| 92 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixing in position White Indian Water Closet,ORISSA PAN of size 580 mm X 440 mm, of standard approved make withP or S trap of approved quality [confirming to the relevant BIS specification of the latest edition] with or without vent with all jointing materials, including necessary excavation, making hole in masonry & making good the same, encasing the pan & trap with PCC& backfilling extra space with river sand of approved quality, curing, cleaning & washing the work area with clean water and disposing the debris / unwanted materialsoutside the periphery of work premises etc., complete all as per specifications, as per manufacturer\"s specification and as directed by the Engineer-in-charge at all locations & at all lifts / heights.Note: Providing & placing of PCC 1:3:6 will be paid under relevant PCC Item. |
| 93 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixing in position Low Level Unbreakable Polymer Flushing Cistern of 10 Litres Capacity of approved brand/make with all internal fittings, including assembling the cistern components, mounting the same with suitable brackets,necessary PVC Flush bend, washer, suitable tools & tackles; required consumables & ensuring smooth functioning etc.,complete as per specifications conforming to IS 2556-1970 with all necessary jointing materials, chasing / making holes in masonry, making good the surface, cleaning the work area etc., complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-In-Chargeat all locations and at all lifts / height. |
| 94 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixing in position of approved brand white vitreous china hand wash basinof size 550X400mm with Plain Rims confirming to the relevant BIS specification of the latest editionwith all necessary jointing materials, chasing / making holes in masonry, making good the surface, cleaning the work area etc., complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-In-Chargeat all locations and at all lifts / height. |
| 95 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixing in position of approved brand Stainless steel Kitchen Sinkof size 600X450x250 mm with Plain Rims confirming to the relevant BIS specification of the latest edition etc., complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-In-Chargeat all locations and at all lifts / height. |
| 96 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and Fixing15 NB;CP brass Bib Tap-15NB and shall not be less than 450 gm. with CP wall flange and other required accesseries including labour charges & all required consumables and ensuring smooth functining etc., complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-in-charge at all locations & at all lifts / heights. |
| 97 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and Fixing15 NB; Long Body CP brass Long Bib Tap-15NBwith CP wall flange and other required accesseries including labour charges & all required consumables and ensuring smooth functining etc., complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-in-charge at all locations & at all lifts / heights. |
| 98 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and Fixing approved brand/make 15 NB; Concealed Stop Stop Cock, weight of each 15 NB shall not be less than 450 gm., with CP wall flange and other required accesseries including labour charges & all required consumables and ensuring smooth functining etc., complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-in-charge at all locations & at all lifts / heights. |
| 99 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and Fixing approved brand/make 15 NB; Angle Valve, weight of each 15 NB shall not be less than 450 gm., with CP wall flange and other required accesseries including labour charges & all required consumables and ensuring smooth functining etc., complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-in-charge at all locations & at all lifts / heights. |
| 100 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixing 15 NB PVCInlet connectionswith brass check nuts at both ends & with \"X\" Nipple of length 450 mm ofApproved brand / Makewith all its required accessories including labour charges & all required consumables and ensuring smooth functioning etc., complete all as per specification and as directed by the Engineer-in-charge at all locations & at all lifts. |
| 101 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixing PVC heavy duty Nahani Trap (SWR Fittings IS:14735)[floor trap]100X75mmof self cleaning design with 75 mm. outlet having a minimum water seal of 50 mm of Approved Brand / make with PVC grating of 125 mm dia [of approved quality & make], finishing neatly, curing, ensuring smooth functioning, including labour charges, required tools & tackles,& consumables, Cleaning & washing / mopping,the work area, disposing off waste materials / debris etc., upto a lead of 100 Mts outside the periphery of work premises etc., complete all as per specification and as directed by the Engineer-in-charge at all locations & at all lifts. |
| 102 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and Fixing 5 mm thick Approved brand / make bewelled edge Mirror of size [600 mm X 450 mm]made out of best Indian glass mounted on 6 mm thick marine plywood sheet backing and teak wood beading alround of size25 mm Wide, 15 mm thick of approved shape & design fixed to the wall using two numbers of CP coated hanging clips, washers, rawl plugs & screws etc. Complete all as per specification and as directed by the Engineer-in-charge at all heights & at all locations. |
| 103 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixing CP brass Tower Rail 600 mm long with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved makeetc. Complete all as per specification and as directed by the Engineer-in-charge at all heights & at all locations.. |
| 104 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixing of CP brass over head shower set with shower rose and shower arm conforming to I.S Specification of approved makeetc. Complete all as per specification and as directed by the Engineer-in-charge at all heights & at all locations. |
| 105 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing & fixing of CP health faucet of approved makeetc. Complete all as per specification and as directed by the Engineer-in-charge at all heights & at all locations. |
| 106 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixing CP grating of 6mm thick with rim including setting in floor with white cement mortar and making good the floor. |
| 107 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and Fixing approved brand/make 15 NB; Pillar Tap, weight of each 15 NB shall not be less than 450 gm., with CP wall flange and other required accesseries including labour charges & all required consumables and ensuring smooth functining etc., complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-in-charge at all locations & at all lifts / heights. |
| 108 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing andlaying / fixing CPVC Pipes & its required Fittings[Pipes & Fittings shall be of plumbing quality ofapproved brand/ Make and confirming to the IS:15778 Schedule D - 80 specification of the latest edition] including providing & fixingfittings like collars, elbows, tees, unions, coupling, reducers, enlargers, bends, nipples and all other fittings required for completing the job, as per code of practice for water supply to the buildings [BIS 2065ofthe latest edition], fixing on thewall surfaceof the building with suitable clamps, jointing the pipes & fittings using CPVC solventcost of all materials like white or red lead, clamps, cement, sand, tools & takles, testing the pipe with clean water as per specifications and ensuring smooth functioning, providing; fixing & removing necessary staging / platformcleaning & washing / mopping the work area, disposing off waste materials / debris etc., complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-in-charge at all locations & at all lifts.( Internal ( concealed)Piping works) |
| 109 | 20mm dia |
| 110 | 25mm dia |
| 111 | 32mm dia |
| 112 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing andlaying / fixing CPVC Pipes & its required Fittings[Pipes & Fittings shall be of plumbing quality ofapproved brand/ Make and confirming to the IS:15778 Schedule D - 80 specification of the latest edition] including providing & fixingfittings like collars, elbows, tees, unions, coupling, reducers, enlargers, bends, nipples and all other fittings required for completing the job, as per code of practice for water supply to the buildings [BIS 2065ofthe latest edition], fixing on thewall surfaceof the building with suitable clamps, jointing the pipes & fittings using CPVC solventcost of all materials like white or red lead, clamps, cement, sand, tools & takles, testing the pipe with clean water as per specifications and ensuring smooth functioning, providing; fixing & removing necessary staging / platformcleaning & washing / mopping the work area, disposing off waste materials / debris etc., complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-in-charge at all locations & at all lifts.(External Piping works) |
| 113 | 32mm dia |
| 114 | 40mm dia |
| 115 | 50mm dia |
| 116 | 65mm dia |
| 117 | 80mm dia |
| 118 | 100mm dia |
| 119 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing, laying,jointing, fixing and testing of approved sewage quality SWR UPVC pipes including fitting like collars,elbow,Tees,Unions,Couplings,Reducers,Enlargers,bBends,Nipples and all other fittings required for completion as per the code of practice of water supply to Buildings(IS 2065 latest edition) including laying under the floors,chasing in walls,roof slab including concealing in walls and floors wherever required and making goodthe same to the original conditions including cost of all materials like PVC solvets,clamps,wooden gutties,screws,cement sand etc including testing the pipe with clean water as per specifications etc.complete all as per specification, as per manufacturer\"s specification and as directed by the Engineer-in-charge at all locations & at all lifts. |
| 120 | 75mm dia (4kg / sq.cm) |
| 121 | 110mm dia (4 kg / sq.cm) |
| 122 | 160mm dia (6kg/sq.cm) |
| 123 | 200mm dia (6kg/sq.cm) |
| 124 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). |
| 125 | 25 mm dia |
| 126 | 32 mm dia |
| 127 | 40 mm dia |
| 128 | 50 mm dia |
| 129 | 65 mm dia |
| 130 | 80mm dia |
| 131 | 100mm dia |
| 132 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and fixing brass ball valve high/ low pressure with plastic float of approved quality 25mm dia noinal bore including cost of material, labour etc., complete. |
| 133 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and construction of Gully chamber using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, providing & fixing square – mouth with 150 x 100mm size P trap S.W. gully trapgrade “A” ,CI cover with frame of 300 x 300mm size (inside) and total weight of cover with frame to be not less than 7.2 kgs ( cover 4.5, frame 2.70 kg) as per standard design , foundation concrete M15 with 40mm concrete and inside plastering 12mm thick cement mortar 1:3 finished smooth with floating coat of cemnet on walls and bed, external plastering 20mm thick in CM1:4, etc., complete as per standards and directed by Engineer. |
| 134 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and construction of brick masonry Inspection chamber 600x850 and 450mm depth (Clear inside dimension) for pipeline with one or two inlets , using table moulded non-modular bricks of class designation 50 in cement mortar 1:4, CI cover with frame 600x 850 internal dimnsion, total weight of cover with frame to be not less than 38 kgs. RCC top slab with cement concrete M20 with 20 mm down size metal, foundation concrete M15 with 40mm concrete and inside plastering 12mm thick cement mortar 1:3 finished smooth with floating coat of cemnet on walls and bed, external plastering 20mm thick in CM1:4, etc., complete as per standards and directed by Engineer. |
| 135 | Extra for depth beyond 450mm for every 150mm thereof.. |
| 136 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and laying of RCC NP2sewer line for underground drainage laid under the soil with required slopes, including hunching / Covering only the joints with cement martor 1:3 at all the joints and testing of joints etc. complete. |
| 137 | 150mm dia |
| 138 | PART- B (WATER SUPPLY & SANITORY WORKS)Filling in plinth by soil including spreading in layers, watering, consolidating to 200mm thickness and finished to the desired level etc. complete as per specifications, relevant IS and as directed by Engineer-in-Charge. |
| 139 | Using soil obtained from burrow pits |
| 140 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and laying in proportion P.C.C1:3:6Plain cement concrete using 20mm down crushed aggregate of approved quality for mudmatleveling course for foundation, plinth and below flooring including form work wherever necessary, consolidation, leveling, finishing and curing etc complete as per specification and as directed by Engineer-in-Charge. |
| 141 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and Constructing R.R. masonry, using hard; durable & approved quality stones / rubbles, in CM 1:6 for foundation works & all other miscellaneous RR masonry works etc., including racking out all the masonry joints or simultaneous flush pointing, providing; fixing & removing necessary staging / platform wherever; as & when required / directed, close hacking the old / new concrete / plastered surfaces forproper / good bonding, base shall be fully neat, clean & slightly wet before laying masonry, Curing for a minimum period of 7 days, cleaning the work area & disposing the debris / waste materials / unwantedmaterials / things etc., upto a lead of 2000 meters outside the pheriphery of work premises etc. complete all as per specification and as directed by the Engineer-in-charge at all locations and at all lifts / heights. |
| 142 | PART- B (WATER SUPPLY & SANITORY WORKS)Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) |
| 143 | Light shade pigment using white cement |
| 144 | PART - C (ELECTRICAL WORKS)Supply, erection, testing and commissioning of cubical floormounting front operated MAIN SWITCHBOARD - MSB-1 for feeding total power requirement ofthe apartment block comprising of the following.Incomer:1 No - 400A 4P MCCB Thermal Magnetic Type complete with FD Kitand in 35KAas mains incomer.1 Set of RYB Phase indication Lamps. 1 Set Breaker ON-OFF Indicatiom lamps.1Set suitable CT with Digital A, V, KW, KWHR, F and PF Indications complete.Outgoings:1 NO - 250A 4P MCCB Thermal Magnetic Type complete with FD Kit in 25KAfeeding Fire Pump Panel. 2 No - 200A 4P MCCB Thermal Magnetic Type complete with FD kit in 25KAfeedingBusduct -1 and Busduct-2. 1 NO - 160A 4P MCCB Thermal Magnetic Type complete with FD kit in 25KA for futue capacitor Bank. 1 NO - 125A 4P MCCB Thermal Magnetic Type complete with FD kit in 25KAfeeding CADB-1. 1 NO - 125A 4P MCCB Thermal Magnetic Type complete with FD kit in 25KAas spare. The unit complete with aluminium busbar interconnections, circuit labels complete. |
| 145 | PART - C (ELECTRICAL WORKS)Supply, erection testing and commissioning of cubical floor mountig front operated common area switchboardCASB-1for feeding lighitng and power requirement at common areas including one light and fan at each apartment comprising of the following.Incomer:1 No- 125A 4P ATS complete with single phasing preventor, Auxilary contactorand Timer complete for Auto-Changeover operation. 1- Set of RYB Phase indications on 2 source of supplyand pushbuttons. 1- Dual source metercomplete with CT in suitable range.Outgoings: 1 No - 63A 4P MCCBin 25KA, thermal Magnetic type complete with FD kitfeeding Lift Motor panelLMP-1. 3 No - 63A 4P MCCB thermal Magnetic Type complete with FD kit and in 25KA feeding Pumps Panel. 3 No - 40A 4P MCBin 10KA feeding CADB-1.1, 1.2 and 1.3 Basement, Stilt and Common area lighitng and power. 1 No - 63A 4P MCB in 10KA feeding riser cable to feed emergency light and fan in each apartment. 1 No - 40A 4P MCB 10KA as spare. The unit complete with aluminium busbar and copper wire interconnections,internal wiring, internal earthging complete. |
| 146 | PART - C (ELECTRICAL WORKS)Supply, erection, testing and commissiongriser Busduct-1 &2, in 200A TP&Nsandwich type with aluminium busbars for feeding lighting and powerat typical floors complete. The unit should have tap-off facility to tap power at each floor through tap-off boxes complete.The unit should be complete earth bubar on either side in continuous run complete. |
| 147 | PART - C (ELECTRICAL WORKS)Supply and providing end feed unit for the above said Busduct comprising of the following.1 No- 200A 4P MCCB in 25KA,thermal magnetic type complete with FD kit and sheet metal enclosure in suitable size to terminate at one end armoured aluminium conductor cable in size of 3.5Cx120sqmm and the other end to terminate to busduct with tinned copper flexibles. |
| 148 | PART - C (ELECTRICAL WORKS)Supply and providing Tap-off boxes in sheet metal housing 100A 4P MCCB in 25KAthermal Magnetic typecomplete with FD kit for feeding Metering panel in each floor. |
| 149 | PART - C (ELECTRICAL WORKS)Supply and providing Metering PanelMETERING PANEL 1-9 cubical wall mounting front operatedin each floor for feeding lighting and power each floor apartments comprising of the following.Incomer:1 No - 100A 4P MCCB in 25KA Thermal Magnetic type complete with RYB Phase indication lamps.Outgoings:6No. Outgoing metering compartments each comprising of the following.1 No. 63A Porcelain Fuse Carrier complete with 32A neutral Link. 1- Metering chamber with hylam base to mount 0-20A Dircet reading energy meter. 1 NO - 32A DP MCBfor protection / isolation of power to each compartment.The unit complete with aluminium busbar and copper wire interconnections, internal wiring, internal earthing complete. |
| 150 | PART - C (ELECTRICAL WORKS)Supply, erection, testing and commissiong of cubical wall mounting front operated Lift Motor Distribution board LMP-1 for feeding Lift panel including lift car and lift shaft lighting comprising of the following.Incomer:1 No - 63A 4P MCCB as incomer.Outgoings:2 No -32A 4P MCBin 10KA as outgoings feeding lift car power.2 No - 25A DP MCB in 10KAfeedingLMP-1.1 lift shaftpower sockets and lift car lighting.The unit complete with aluminium busbar and copper wire interconnections, circuit labels, internal control wiring, internal earthing complete. |
| 151 | PART - C (ELECTRICAL WORKS)Supply and providing 12Way SP&N Double Door MCB LMP-1.1 distribution board for feeding lift car and lift shaft lighting comprising of the following.Incomer:25A DP ELCB in 100mA as incomer.Outgoings: 8 No. 10A SPMCB asoutgoings. 2 No. Dummy.The unit complete with insulated copper busbar interconnections, internal wiring internal earthing complete. |
| 152 | PART - C (ELECTRICAL WORKS)Supply, erection, testing and commissioning of 4 Way TP&N Double Door MCB distribution board CADB-1.1, 1.2 and 1.3feeding Common area lighting and power comprising of the following.Incomer:1 No. 25A 4P 100mA ELMCB as incomer.Outgoings: 12 No. 10/16/20A SPMCB in 10KA The Distribution Board complete with insulated busbar interconnections, circuit labels complete.The unit should be mounted in concealed fashion. |
| 153 | PART - C (ELECTRICAL WORKS)Supply and providing 12WAY SP&N Double door MCB distribution board metal clad LPDB-1.1 TO LPDB 9.6 for feeding lighting and small power at each flots comprising of the following.Incomer:-1 No - 32A DP ELMCB in 100mA as incomer.Outgoings:- 4 No. 10A SPMCB in 10KA feedinglighting circuits. 5 No. 20A SPMCB in 10KA feeding Power circuits.The unit should be complete with insulated busbar interconnections, internal wiring, internal earthing complete. |
| 154 | PART - C (ELECTRICAL WORKS)Supply and providing Busbar - Junction boxmetal clad at each floor 4P version in 63A Capacity for tapping power at each floor to feedemergency light and fan in each flat complete. |
| 155 | PART - C (ELECTRICAL WORKS)Supply and providing wall mounting front operated distribution board metal clad for feeding emergency light and fan in each flat comprising of the following.1 No. 10A DP 100mA ELMCB as incomer.Outgoings:- 6 No. 10A DP switch.The unit complete internal wiring with copper wires,internal earthing complete. |
| 156 | PART - C (ELECTRICAL WORKS)Supply and proviiding in concealed fashion 10ADouble poleChangeover switch for emergencylight and fan power changeover application in each flat comprising of the following. |
| 157 | PART - C (ELECTRICAL WORKS)Supply and providing Fire panel FMP-1 for feeding Fire pump comprising of the following.1 No. 63A TP&N MCCBlinking suitable contactor with Overload relay for 7.5HP motor. The starter unit should also suitable auxilary contact to operate by pressure switch for fire fighting application. |
| 158 | PART - C (ELECTRICAL WORKS) CABLES/CIRCUIT MAINS:Supply and laying of following size cables on wall/ceiling complete with rigid clamping arrangement. |
| 159 | 3.5Cx240sqmm armoured aluminium conductor cable from Main Feeder to the MSB-1 at Basement. (OPTIONAL) |
| 160 | Termination of above cable with single compression gland and sockets.(OPTIONAL) |
| 161 | 3.5Cx120sqmm armoured aluminium conductor cable. |
| 162 | Termination of above cable with single compression gland and sockets. |
| 163 | 3.5Cx70sqmm armoured aluminium conductor cable. |
| 164 | Termination of abovecable with single compression gland and socket. |
| 165 | 3.5Cx35sqmm armoured aluminium conductor cable. |
| 166 | Termination of abovecable with single compression gland and socket. |
| 167 | 4Cx16sqmm armoured aluminium conductor cable. |
| 168 | Termination of above cable with single compression gland and sockets. |
| 169 | 2R, 6sqmmand 1R, 2.5sqmmPVC insulated copper conductor wire taken in already laid PVC pipe complete for circuit mains wiring from Metering Panel in each floorto respective DB in each flatcomplete.. |
| 170 | Terminationof above set of wires with suitable copper sockets. |
| 171 | PART - C (ELECTRICAL WORKS) ELECTRICAL WIRING INSTALLATION:NOTE:Concealed PVC conduit wiring should be adopted in wiring installation. All civil works related to wiring installatin such as chasing of walls for embedding PVC pipes and switch boxes and necessary rough plasteringshould be part of the wiring work.Clearingof debris generated by breaking of walls will be part of electrical contracts scope of work. All conduits and wires used inthe wiring installation should be of FRLS Version only.AllPVC pipes and wires used in the wiring installation should be only FRLS.Generally all switchesshould be at 1200mm height from FFL for lightand fan controls. All Kitchen socketsat 1350mm height. All bed side switches at 600mm height. All TV power sockets and TV outlets at 600mm Height. All general Power sockets at 250mm Height.Bathroom switches at 1350mm Height. Geyser Socket at 2400mm Height. AC control at 250mm Height for Split unitfor Window the switch socket outlet should be at 900mm Height. |
| 172 | PART - C (ELECTRICAL WORKS) Basement and Stilt Floor Electrical wiring installation.Supply and providingconcealed wiring for light points wired from modular switch control with 2R, 1.5sqmm PVC insulated copper conductor FRLS wire as phase and earth and 1R, 1.5Sqmm PVC insulated copper conductor wire FRLS as phase wire for each fitting taken in 20/25mm PVC pipe complete with accessories. The rate quoted should be inclusive necessary chasing of walls for concealing of pipes rough plasteringby providig mesh complete. The rate quoted should also be inclusive of providing combination switches and sockets of modular range. |
| 173 | 1 Light Controlled by 1 Switch |
| 174 | 2 Lights Controlled by 1 Switch |
| 175 | Fan Point with electronic regulator. |
| 176 | PART - C (ELECTRICAL WORKS) Basement and Stilt Floor Electrical wiring installation.Supply and laying in concealed fashion3R, 1.5sqmm PVC insulated copper conductor FRLS wiretaken in 20mm PVC pipe complete with accessories as circuit mains. |
| 177 | PART - C (ELECTRICAL WORKS) Basement and Stilt Floor Electrical wiring installation.Supply and laying in concealed fashion2R, 2.5sqmmand 1R, 1.5Sqmm PVC insulated copper conductor FRLS wiretaken in 20mm PVC pipe complete with accessories as circuit mains. |
| 178 | PART - C (ELECTRICAL WORKS) Basement and Stilt Floor Electrical wiring installation.Supply and laying in concealed fashion of 2R, 4sqmm and 1R, 2.5sqmm PVC insulated copper conductor FRLS wiretaken in 25mm PVC pipe complete with accessories for power sockets wiring. |
| 179 | PART - C (ELECTRICAL WORKS) Basement and Stilt Floor Electrical wiring installation.Supply and providing 16A switch socket assembly modular range in a metal box completeand fixed flush with the wall. |
| 180 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:.Supply and providingconcealed wiring for light points wired from modular switch control with 2R, 1.5sqmm PVC insulated copper conductor FRLS wire as phase and earth and 1R, 1.5Sqmm PVC insulated copper conductor wire FRLS as phase wire for each fitting taken in 20/25mm PVC pipe complete with accessories. The rate quoted should be inclusive necessary chasing of walls for concealing of pipes by providing mesh wherever required and rough plastering complete. The rate quoted should also be inclusive of providing combination switches and sockets of modular range. |
| 181 | 1 Light Controlled by one switch |
| 182 | Fan points with step type electronic Regulator |
| 183 | Exhaust Fan point |
| 184 | Call Bell Point |
| 185 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and providingconcealed wiring for 6A Plug points wired from circuit mains end point and wired withwith 3R, 1.5sqmm PVC insulated copper conductor FRLS wire taken in 20/25mm PVC pipe complete with accessories. The rate quoted should be inclusive necessary chasing of walls for concealing of pipes and rough plastering by providing mesh complete. The rate quoted should also be inclusive of providing combination switches and sockets of modular range as per the configuration detailed below. |
| 186 | 1 No. 6A switch socket assembly point. |
| 187 | 2 No. 6A switch Socket assembly point |
| 188 | 1 No. 6A switch socket assembly in switchboard itself. |
| 189 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and laying in concealed fashion3R, 1.5sqmm PVC insulated copper conductor FRLS wiretaken in 20mm PVC pipe complete with accessories as circuit mains. |
| 190 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and laying in concealed fashion2R, 2.5sqmmand 1R, 1.5Sqmm PVC insulated copper conductor FRLS wiretaken in 20mm PVC pipe complete with accessories as circuit mains. |
| 191 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and laying in concealed fashion of 2R, 4sqmm and 1R, 2.5sqmm PVC insulated copper conductor FRLS wiretaken in 25mm PVC pipe complete with accessories for power sockets wiring. |
| 192 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and providing 16A switch socket assembly modular range in concealed fashion in a metal box complete power application. |
| 193 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and providing 16A Switch and socket mounted separately for Geyser application in each bathroom complete. |
| 194 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and providing 32A DP switch inModular range and fixed in concealed fashion complete with back box for Split AC unit application.. |
| 195 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and providing TV outler modular range in concealed fashion complete for TV application. |
| 196 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and providing RJ-11 Telephone outletin concealed fashion complete for Voice application. |
| 197 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and providing following sizes of PVC Pipes for Circuit mains / TV/Telephone and Networking application. |
| 198 | 20mm |
| 199 | 25mm |
| 200 | 32mm |
| 201 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and laying of following sizes of Networking and voice wires in already laid PVC conduits in concealed fashion complete. |
| 202 | 3 Pair Telephone wire for voice application, |
| 203 | PART - C (ELECTRICAL WORKS) Typical Flats Electrical Wiring Instalaltion:Supply and laying of RG-6 TV Co-axial wire taken in already laid PVC conduit complete for TV system. |
| 204 | PART - C (ELECTRICAL WORKS) Havells REGAL Model box type luminaire with2x22WLed Tuberetro fit type for Basement and Ground Floor Car Park Area LUMINAIRES:NOTE:All light fittingsand fans should be properly erectedas per standards. All accessories / supportive items required for erection of fittings and fans should be part of the erection rates.Supply and erection of following luminaires / fans complete as per the model and make specified. |
| 205 | PART - C (ELECTRICAL WORKS) Havells Pluto Surface 34W LED Grid fitting in size of 600x600mm at Ground Floor Porch and Entrance Lobby |
| 206 | PART - C (ELECTRICAL WORKS) Havells BoltModel18W LED Panels Surface Mounting type for Lift Lobby Area. |
| 207 | PART - C (ELECTRICAL WORKS) Havells RUGBY Model Bulk Head Fittings 10W LED Lamp at Terrace Area |
| 208 | PART - C (ELECTRICAL WORKS) Havells CITY-4Walllight with 14W LED lampat Ground Floor Landscape Area |
| 209 | PART - C (ELECTRICAL WORKS) Havells CITY-3 Decorative wall light fixture with 10W LED Lamp |
| 210 | PART - C (ELECTRICAL WORKS) Crompton HSLVwhite body Ceiling Fans in 900/1050/1200mm Dia complete for Flats |
| 211 | PART - C (ELECTRICAL WORKS) HavellsREO - Model Ding Dong Calling Bell for Flats |
| 212 | PART - C (ELECTRICAL WORKS) Havells - Model E-Lite LED Curve 1x20W Batton Luminaire complete with 20W LED Lamps for Flats. |
| 213 | PART - C (ELECTRICAL WORKS) HavellsVENTILAIR DB Double Ball Bearingheavy duty version exhaustfan in 230mmcomplete with bird guard. |
| 214 | PART - C (ELECTRICAL WORKS) Supply Installation And commissioningof 10liters GyserofBrannd makelike Havvelsor Equivalentmake , 2 mm Thicksouuer cold rolledsteel plates ,5 Satr rating including heatingelement . Earth Leakeage circuit Breaker(ELCB ) Vitreous enamel coated tank CFC free thicker PUF insulaton, whril flow technologywith adestable knob for Tempature setting including the Hot and cold supply flexible connection etc complete-. |
| 215 | PART - C (ELECTRICAL WORKS) EARTHINGSupply and providing GI Pipe earth electrode in size of 63mm dia B-Class GI Pipe and in length of 2.4mt complete with flange at one end. The rate quoted should also be inclusive of providing necessry pre-cast masonry chamber in size of 350x350mm complete. |
| 216 | PART - C (ELECTRICAL WORKS) EARTHINGSupply and laying of following size GI / COPPER flats for interconnecting equipments with earth pits. |
| 217 | 40x6GI Flat |
| 218 | 25x6GI Flat |
| 219 | 25x3GI Flat |
| 220 | 25x3Cu Flat |
| 221 | PART - C (ELECTRICAL WORKS) EARTHINGSupply and laying of No.8G copper wire for earthing application. |
| 222 | PART - C (ELECTRICAL WORKS) EARTHINGSupply and laying of No.10G copper wire for earthingapplication complete. |
| 223 | PART - C (ELECTRICAL WORKS) EARTHINGSupply and fixing of earth bus made of 25x6mm GI flat in length of 250mmcomplete. |
| 224 | PART - C (ELECTRICAL WORKS) MISCELLENEOUS:Supply and laying of following sizes of PVC conduits in concealed fashion for TV/Telephone system. |
| 225 | 20mm |
| 226 | 25mm |
| 227 | 32mm |
| 228 | PART - C (ELECTRICAL WORKS) MISCELLENEOUS:Supply and providing following sizes closed type PVC trough complete. |
| 229 | 25x25mm |
| 230 | 40x40mm |
| 231 | 50x50mm |
| 232 | 100x50mm |
| 233 | PART - C (ELECTRICAL WORKS) MISCELLENEOUS:Supply and providing following sizes sheet steel galvanized wall boxes made of 16G sheet steel complete. The front cover should be powder coated to match the wall colour. |
| 234 | 100x100x35mm |
| 235 | 150x100x35mm |
| 236 | 200x150x35mm |
| 237 | 250x150x35mm |
| 238 | 300x200x35mm |
| 239 | 400x200x35mm |
| 240 | PART - C (ELECTRICAL WORKS) MISCELLENEOUS:Supply and providing following safety equipment at electrical room. |
| 241 | Tested variety rubber gloves |
| 242 | Tested variety rubber mats 6mm thick and in size of 1mtx2mt. |
| 243 | First aid BOX |
| 244 | First AID Chart |
| 245 | 5KG fire extinguisher /dry type |
| 246 | 3No -Fire buckets in common stand |
| 247 | PART - C (ELECTRICAL WORKS) MISCELLENEOUS:Supply and providing following sizes of GI ladder type cable tray made of 2mm thick sheet steel with main runner in 75mm wide for tray sizes from 400 to 1200mm and 50mm wide for tray in sizes of 150 to 300mm complete. |
| 248 | 150mm Wide |
| 249 | 300mm Wide |
| 250 | 400mm Wide |
| 251 | PART - C (ELECTRICAL WORKS) MISCELLENEOUS:Supply and providing Sand Cushioning for cable in the trench complete. |
| 252 | PART - C (ELECTRICAL WORKS) MISCELLENEOUS:Supply and providing V-Trough for main feeder cable complete. |
| 253 | PART - C (ELECTRICAL WORKS) MISCELLENEOUS:Supply and providng Steel suports made of angles/ channelsfor supporting trays, distribution boards, panels complete. |
| 254 | PART - C (ELECTRICAL WORKS) LIGHTNING PROTECTION:Supply and providing ACTIVE Lightning Protection system of reputed make for the size of the terrace area complete with counter strike indicator necessary supports, string wires (if required) complete. |
| 255 | PART - C (ELECTRICAL WORKS) LIGHTNING PROTECTION:Supply and providing 95sqmm PVC insulated copper wire taken in 40dia GI Conduit complete as down conductor. |
| 256 | PART - C (ELECTRICAL WORKS) LIGHTNING PROTECTION:Supply and providing GI Pipe earth electrode in size of 63mm dia B-Class GI Pipe and in length of 2.4mt complete with flange at one end. The rate quoted should also be inclusive of providing necessry pre-cast masonry chamber in size of 350x350mm complete. |
| 257 | PART - D (FIRE FIGHTING WORKS)Providing, cutting,fabricating, erection, testing and commissioningoffollowing dia heavy duty GI class ‘C’ tubes confirming to IS: 1239 Part – I for fire fighthing works. GI pipes shall be provided with welded joints only unless flanges are warranted and Galvanized, supports at standard spacing, anchor fasteners, bolts, nuts, clamps, rails \"U\" & threaded bolt. All fittings shall be heavy duty GIThe pipi line shall be painted with one coat of primer and two coat of enamel / Anti-corrossion paint etc., complete. |
| 258 | 80 mm dia |
| 259 | 100mm dia |
| 260 | 150mm dia |
| 261 | PART - D (FIRE FIGHTING WORKS)Providing and fixing following Suitable Flanges forfollowing dia f pipes. Flanges shall be of the forged steel, flat faced slip on type in accordance with IS:6392 withpressure class suitable for the system working pressure involved but in no case less than 16 Bar. Jointing face of the flanges shall be truly parallel to each other and in alignment. A suitable gasket of theapproved type minimum 1.5mm thick shall be used between each jointing flange. Bolts shall be of hexagon head and shall be of adequate length such that at least three complete threads protrude through the hexagonal nut with washers when the flanged joints are fully tightened. |
| 262 | 80 mm dia |
| 263 | 100mm dia |
| 264 | 150mm dia |
| 265 | PART - D (FIRE FIGHTING WORKS)Providing and fixing Butterfly valves conform to IS 5312.Butterfly Valves shall conform the following specification:Body : High duty cast iron to IS 210 Gr. FG 220 and BS 1452 Gr. 220.Seating : Molded insitu resilient lining of black nitrile rubber.Disk : Nylon coated S.G. Iron to IS 1865/SG 400/12 and BS 2729 Gr.420/12.Shaft : The shafts are made of stainless steel AISI 431. Only flanged end valves to be used with flanges drilled to BS 10 Table F. Valves shall be capable of being locked in open position. Hand wheel shall be with vertical gear unit for smooth opening and closing of the valve. |
| 266 | 80mm dia |
| 267 | 100mm dia |
| 268 | PART - D (FIRE FIGHTING WORKS)Providing and fixingof FIRST-AID HOSE-REEL FOR FIRE FIGHTING as per IS: 884: 1985 (Reaffirmed 2015) (type A) Swinging (180°) wall mounting type, complete with all accessories as per the technical specification given in section -V. |
| 269 | PART - D (FIRE FIGHTING WORKS)Providing and fixing of Non Percolating Polyster Jacketed Flexible Fire Fighting Delivery Hose of 15 mtr length as per IS 636: 1988 (Reaffirmed 2003) - ‘Type B’. with all accessories as per the technical specification given in section -V. |
| 270 | PART - D (FIRE FIGHTING WORKS)Providing and fixing Single headed Stainless Steel Landing (Hydrant) Valves of approved make as per IS:5290 Type-A, ISI Marked suitable inHydrant Systems as per the technical specification given below:MOC : Stainless Steel(IS:3444 Gr.I or IS:3444 Gr.IV)Inlet : 75mm NB Flanged as per IS:1538 /As per ANSI B 16.5 150 ClassOutlet : Standard 63mm Female InstantaneousSize : 63mmTest Pressure : 21 kgf/cm2 |
| 271 | PART - D (FIRE FIGHTING WORKS)Providing and fixing Double headed Stainless SteelYard Hydrant Valves of approved make as per IS:5290 Type-A, ISI Marked suitable inHydrant Systems . |
| 272 | PART - D (FIRE FIGHTING WORKS)Provodong and fixing Stainless steel Delivery Hose Coupling confirming to IS 903 of approved make. |
| 273 | PART - D (FIRE FIGHTING WORKS)Provodong and fixing Stainless stell Branch Pipe with Nozzles confirming to IS 903 of approved make. |
| 274 | PART-E (8 Capacity Lift 2 Nos)Design, manufacture and supply of 544kg (8 Passanger) with machine room passanger lifts. |
| 275 | PART-E (8 Capacity Lift 2 Nos)Installation, Testing, commissioning of (8 Passanger), Machine room lifts including statutory requirements. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail