Tender For Kanpur Nagar Separate Rajkiya Housing Colony Circuit House Type 4 Housing Number 1 28 29 30 31 32 33 34 Special Repair and Renovation Work in Housing of People 35 - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSPVC insulated copper conductor single core cable insurface/recessedmediumclassPVCconduit withpiano type switch, phenolic laminated sheet suitableM.S. box and earthingthepointwith1.5sq.mm.FRLSPVCinsulated copper conductor single core cable etc. as required. Group B 2 Wiring for twin control light with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLSH PVC insulated copper conductor single core cable etc. asrequired. 3 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 2 X 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 5 2 X 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 6 2 X 4 sq. mm + 1 x 4 sq. mm earth wire 7 2 X 6 sq. mm + 1 x 6 sq. mm earth wire 8 2 X 16 sq. mm + 1 x 6 sq. mm earth wire 9 4 X 16 sq. mm + 2 x 6 sq. mm earth wire 10 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 11 100 mm X 100 mm X 60 mm deep 12 180 mm X 100 mm X 60 mm deep 13 200 mm X 250 mm X 60 mm deep 14 Supplying and fixing metal box of 150 mm x 75 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 a socket outlet and 5/6 A piano type switch, connection, painting etc as required. 15 Supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connection, painting etc as required. 16 Supplying and fixing 3 pin, 5 A celling rose on the existing junction box/wooden block including connection etc. as required. 17 Supplying and fixing brass batten / angle holderincluding connection etc. as required. 18 Installation, Testing, Commissioningof wall bracket / celling fittings of all sizes and shapes contaning upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connection etc. as required. 19 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 20 Installation of exhaust fan in the existing opening, including making good the damage, connection, Testing, commissioning etc. as required. 21 Extra for fixing the louvers/shulters complete with frame for a exhaust fan of all sizes. 22 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 23 8 way, Double door 24 12 way, Double door 25 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 26 4 way(4 + 12), Double door 27 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 28 Single Pole 29 Double Pole 30 Supplying and fixing single pole blanking plate in the existion MCB DB Complete etc. as required. 31 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32 63 A 33 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts C curve DP MCB complete with connections, testing and commissioning etc. as required. 34 Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 35 for 8 way, Double door SPN MCB DB 36 for 10 way, Double door SPN MCB DB 37 Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 38 For 4 way, Double door TPN MCBDB 39 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 40 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 41 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 42 4 X 16 sq. mm (28 mm) 43 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required(For inverter wiring). 44 1 X 1.5 sq. mm 45 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 46 Supply of Heavy Duty Exhaust Fan 300 mm. sweep 900 RPM Single phase complete in all respect. Havells or Eq. 47 Supplyof Metallic bodyfresh air fan 230 mm. sweep complete in all respect.Havells or Eq. 48 Supply and fixing of 7 Watt LED Bulb Output 630 Lm,Color Temp 300 k 0.04 Amp. Havells or Eq. 49 Supply of Decorative wall mounting brushed nickle finish fixture with open glass diffuser suitable for 9 W LED lamp B22 base. Havells or Eq. 50 Supply and fixing of 20 W LED Mirror Light the design is a harmonius blend of curves and angles. Havells or Eq. 51 Supply and fixing ofLED tube light with heavy duty metal box type tube light fitting 1x22 watt. Suitable for up to 1x22 watt LED polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect. CAT-AAA2620 system lumens, >120Lm/W, PF>0.95, THD<10%, CRI>80, sheet thickness min 0.8 mm., tube with aluminium heat sink > 300 V over voltage protection, 2.5 KV internal surge protection with 5 year warrantee. 52 Supply and fixing ofwater tight oblong 10 watt LED bulkhead lumaniare having die cast housing with driver set confirming to IP 65 and above protection IK 08 high purity/transmisivity UV stablized non yellowish diffuser for uniform light distribution detachable driver set open and short circuit protection suitable for 24 Hr continuous operation complete in all respect.CAT-AA1100 system lumens, 110Lm/W, PF>0.95, CRI>70% 300V over volatage protection, 4KV internal surge protection, metal housing with 3 year warrantee. 53 Supply and fixing of 40 Amp. SP MCB (10 KA) 240 V/415 V, 50 Hz, C-Series Havells or Eq. 54 Supply and fixing of 40 Amp. DP MCB (10 KA) 240 V/415 V, 50 Hz, C-Series Havells or Eq. 55 Supply and fixing of 63 Amp. FP MCB (10 KA) 240 V/415 V, 50 Hz, C-Series Havells or Eq. 56 Supply and fixing of FP metal enclosure for MCBMake:-Legrand, Havells or Eq. 57 Dismantalling of old wiring, Distribution & main switch etc. complete in all respect. 58 Cost of 01 No. Residence 59 Cost of 09 No. Residence