}

Tender For Renovation Of The Conference Room At Civil Engineering Department (M-Block) In Academic Complex., guwahati-Assam

Indian Institute Of Technology has published Tender For Renovation Of The Conference Room At Civil Engineering Department (M-Block) In Academic Complex.. Submission Date for this Tender is 08-02-2025. Building Work Tenders in guwahati Assam. Bidders can get complete Tender details and download the document.




Tender Notice

47281016
Corrigendum : Tender For Renovation Of The Conference Room At Civil Engineering Department (M-Block) In Academic Complex.
Open Tender
Indian
Assam
Guwahati
08-02-2025

Tender Details

Tender For Renovation Of The Conference Room At Civil Engineering Department (M-Block) In Academic Complex.; 1 Part A : Civil Works 2 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within the campus as directed by Engineer in Charge. 3 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. 4 Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 100 mm dia pipe 5 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 6 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level 7 Cement mortar 1:4 (1 cement :4 coarse sand) 8 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) 9 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540 F & ISO 11600:Upto 5 mm depth and 5 mm width 10 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) 11 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 12 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content 13 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 14 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete. 15 6mm overall thickness partition using 8mm thick double skin multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process (High pressure steam cured) as per IS : 14862 with suitable fibre cement screws 16 Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturers specification. (a) Two or more coats on new work 17 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 100 mm nominal dia Pipes 18 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 19 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 20 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @ 80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) 21 Step-1 Providing and applying Koster Polysil TG 500 or equivalent primer on the prepared surface as per manufacturers specifications, including cost of materials, labour, consumables, tools and tackles, etc., complete. 22 Step-2 Providing and applying Talrak Flexeal Elastic or equivalent waterproofing coating on the primed surface in two coats, as per manufacturers specifications, including cost of materials, labour, consumables, tools and tackles, etc., complete. 23 Providing and fixing of Natural creation Arbor Art classic/Antique 2 mm thick of Armstrong PVC floor with approved adhesive and joints to be filled up by heat torching. 24 Supply and Installation of channeled woodworks perforated panels with required size, made of moisture resistant fibre board with minimum density of 500-700 NRC upto.75 in approved colour shade with necessary with necessary GI framing. Make-UNIDUS, Anatoune, CALSE, FIBRECRET or Equivalent 25 Supply and Installation of wood wool substrate of size 1200*600 mmin designed fabric fitted with pvc gripper covered having NRC of 0.85 including all necessary fitting and accessories. Make- UNIDUS, ANATONE, CALSI, FIBRECRWT, OR equivalent. 26 Providing and fixing at at all height flase ceiling of 6mm thick (white) finlight PVC foamed sheet of finolex (or equivalent) with necessary screw of approved quality in 200 mm interval both direction to specified frame work, including providing and fixing of frame work made of special section power accordance with znic coating 600 as per IS:277 and consisting of angle cleats of size 25 mm wide *1.6 mm thickwith flanges of 22 mm and 37 mm dia * 40 mm long with 6mm dia bolts to the angle hanger being fixed with nut and bolts to G.I channels 45*15*0.19 mm running at the rate of 1200 mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips og 10.5 mm at 450, including providing fitting and fixing of 19 mm wide melamine polished teakwood liping to each longitudinal direction joints all complete as per drawing and specification and direction of the Engineer in charge 27 Providing, fitting and fixing of UPVC Doors including all accessories. 28 Part B : Electrical Works - I 29 Wiring for light point/ fan point/exhaust fan point/ call bellpoint with 1.5sqmm FRLS PVC insul;ated copper conductor single core cable on surface/ recessed medium class PVC conduit with piano type switch , phenolic laminated sheet suitable sizes MS box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required 30 Supply and drawing following sizes of FR PVC insulated copper conductor,single core cable in the existing surface/recess/pVC conduit as required make Havells/Finolex/RR Kabel or equvalent 31 i) 2 x 2.5 sqmm + 1x 2.5sqmm earth wire 32 ii) 2 x 4 sqmm + 1x 4sqmm earth wire 33 Switch/Socket 34 Supplying and fixing following modular type switch/socket on the existing swith box/cover including connection etc.as required make legrand or equivalent 35 (a) 15 Amp Switch 36 (b) 15 Amp socket 37 (c)5 amps switch 38 (d)5 amps socket 39 Supplying and , fixing of followingmodules GI boxesalong with modular base & cover plate for modular switch in recess etc as required make havels crabtree 40 i) 1 or 2 Module 41 ii) 3 module 42 iii) 6 module 43 v)12 module 44 Supplying and laying of CAT-06 computer cable in existing conduit steel/PVC conduit and termination etc. as required make D-link 45 Supply and drawing following pair 0.50mm dia FRLS PVC insulated annealed copper conductor unarmored telephone cable in the existing surface/ recessd steel/PVC conduit as required 46 i) 2 pair 47 Supplying and fixing following modular type switch/socket on the existing swith box/cover including connection etc.as required make Anchor/ Goldmedel/Kolor or equvalent 48 i) Telephone socket outlet 49 Supply and fixing of following sizes of medium class PVC conduit along withaccessories in the surface/recess including cutting the wall amking good the same in case of recess conduit required 50 i) 20mm dia 51 ii) 25 mm dia 52 Installation testing and commissioing of prewired LED recess type light fittings of all accessories including connection with 1.5sqmm FRLS PVC insulated copper conductor single core cable earthing as required. 53 Part C : Electrical Works - II 54 Supplying and fixing of computer point RJ-45 modualr type in compatiable box along with cover plate etc. complete make legrand or equvalent 55 Supply of 2x2 recess mounting type 36W LED flatpanelwith PDC aluminium housing and PMMA diffuser makes it a robust luminaries CAT no- SSK-TVP-6060-36W (Make-SYSKA) or equivalent 56 Supply of 18W LED 1X1 surface light fittings as per Approved brand (Approved Make Philips/Havells/CG/Bajaj) make Jaguar or equivalent 57 Part D : HVAC - I 58 Supply, installation, testing, and commissioning of CHW cassette unit, ceiling suspended, with 4-way cassette, copper pipe flare fittings, filter, 3-speed motor, motorized valve with actuator & thermostat/remote, drain pump, including control wiring from unit to the existing switch board with switch, socket, casing-capping/conduit pipe, ball valve, two-way valve with Y strainer in supply line and ball valve in return line, necessary copper fittings, as complete and required per specifications. 59 2.0 TR (Nominal Capacity) 60 Providing and fixing Chilled water pipe insulation with 50 mm thick TF quality expanded polystyrine of 20 kg/ m3 density and finaly covered with chiken wire mesh and 10 mm thick sand cement plaster in two layer and two coat of approved brand of painting on the pipes 61 80 mm Dia Pipe 62 Supplying & laying , testing & commissioning mild steel C class pipe of size as mentioned below on exposed surface,wooden support, MS angle- clampalongwith priming coat of steel primer as per standard specification complete as required. 63 25 mm Dia Pipe 64 32 mm Dia Pipe 65 50 mmdia Pipe 66 Providing and fixing Chilled water pipe insulation with 50 mm thick TF quality expanded polystyrine of 20 kg/ m3 density and finaly covered with chiken wire mesh and 10 mm thick sand cement plaster in two layer and two coat of approved brand of painting on the pipes 67 25 mm Dia Pipe 68 32 mm Dia Pipe 69 50 mmdia Pipe 70 Providing and fixing of GI drain water piping with 19 mm thick closed cell nitrile rubber with sand cement plaster complete as required 71 32 NB (medium class) 72 Supply, Insatallation, testing and commissioning ofAuto Air-purge valve of 25mm dia as complete as required. 73 Dismantling aluminium/ Gypsum partitions, GI ductings, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge. 74 Part E : HVAC - II 75 Power Cabling 76 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 77 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 78 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 79 15/16 A switch 80 6 pin 15/16 A socket outlet 81 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 82 3 Module 83 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 84 Providing and fixing in position the following manual Butterfly valve- manual (Insulated)with C I body SS Disc, Nitrile Rubber Seal and O-Ring PN 16pressure rating for chilled water circulation as specified 85 50 mm dia 86 40 mm dia 87 supplying,installation,testing and commissioning of followingindusrial type thermometer and pressure gaugewith ball valves for isolationcomplete as required(supply ) 88 Thermometer 89 pressure gauge 90 Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick nitrile insulation having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. 91 Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 92 19 mm 93 Duct/Grilles/Diffusers 94 Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, support etc. as per approved drawing and specifications of following sheet thickness complete as required. 95 thickness 0.63 mm sheet 96 Providing and fixing of extruded aluminium powder coated grills/diffusers as per specifications and drawings complete as required. 97 Supplying, fixing testing commissioning of supply/return Grill of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core. 98 Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 03-02-2025 Corrigendum 1 Date 08-02-2025

Key Value

Document Fees
Refer document
EMD
INR 58000.0 /-
Tender Value
INR 28.56 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail