Tender For Repair Of Roof Of Existing Library Block At Aps Fazilka.; 1 Excavation in trenches, n.exc 1.5 metre wide and n.exc 1. 5 metre in depth; for foundation or for manholes n.exc 10 Sqm on plan and n.exc 1.5 metre in depthand getting out in soft/loose soil complete all as specified and directed by the Engineer-in-Charge. 2 Excavation in trenches, n.exc 1.5 metre wide and exc 1. 5 metre and n.exc 3.00m in depth; for foundation or for manholes n.exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed by the Engineer-in-Charge. 3 Returning filling in, including spreading, levelling, watering and well ramming in layers each n.exc 25 cm depth in soft/loose soil complete all as specified and directed by the Engineer-in-Charge. 4 Removing surplus spoil to distance n.exc 50 metre and depositing where directed at level n.exc 1.5 metre above the starting point complete all as specified and directed by the Engineer-in-Charge. 5 Taking down chowkats or frames exc. 1.5 sqm but n. exc 4 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed. 6 Supply and fixing factory made UPVC white colour casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension, comprising of UPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in-Charge. (Glass shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this accountshall be made. 7 S&F Door closer aluminium (extruded section body) hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed complete all as specified and directed. 8 Providing and fixing factory made UPVC white colour sliding window three track of area not exc. 2.00 Sqm each, made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash(42mm x 67mm). Sliding mesh sash (42mm x 57mm) sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose. 9 M&L for sheet glass selected quality plain 4.8mm thickness fixed in aluminium door/window shutter cut to required size and fixed with PVC/Neopane gasket etccomplete all as specified and directed. 10 Material and labour 18-20mm thick machine cut, granite (dark colour) minimum size equal to width of slab, duly factory grinding and polished (table rubbed and polished) as in cooking plateform and like laid over and including 20 mm thick bedding layer in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer-in-Charge. 11 Demolition of RCC (reinforcement cut as required to facilitate demolition) roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work or any description and in any position complete all as specified and directed by Engineer-in-Charge 12 M&L for cement concrete 1:4:8, type D2, (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified. 13 M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. 14 All as per Ser item No 13.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified. 15 M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface complete all as specified. 16 M&L for formwork square or rectangular to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface complete all as specified. 17 M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surface complete all as specified. 18 M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; n.exc 200mm thick (horizontal or sloping) for rough finished surface complete all as specified. 19 M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n. exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but n exc. 20cm wide for rough finished surface complete all as specified. 20 M&L RCC M-25 (Design mix) as in foundations, including rafts, footings,foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified. 21 M&L RCC M-25 (Design mix) as in columns, pillars, piers, posts and struts etc. complete all as specified. 22 M&L RCC M-25 (Design mix) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified. 23 M&L RCC M-25 (Design mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified. 24 Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed. 25 M&L Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer - in - Charge . 26 M&L for rendering 15 mm thick in CM (1:6) on other than fair faces of brick work or concrete surfaces of wall, finished even & smooth (without using extra cement) complete all as specified and directed. 27 M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces of wall, finished even & smooth (without using extra cement) complete all as specified and directed. 28 M&L for rendering 5mm thick in cement mortar (1:3) on concrete surfacesfinished even & smooth (without using extra cement) on ceiling complete all as specified and directed. 29 M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of 2 mm thick wall care putty (in two coats each coat of 1 mm) on plastered surfaces of wall complete all as specified. 30 M&L for preparation of new plastered ceiling surfaces & applying two coats of distemper oil emulsion over a coat of primer on plastered surfaces of ceiling complete all as specified. 31 Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm over new surfaces. 32 Dismantling floor, hearth or wall tiling incl cement mortar beding (but not backing), removing serviceable tiles to store and rubbish off the premises asdirected by the Engr-in-Charge. 33 S&F Vitrified Ceramic tiles (light shade) 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15mm thick screed bed in cement mortar (1:4) and pointed in white or colour cement to match the colour of tiles complete all as specified. 34 S&F Vitrified Ceramic tiles (dark shade) 10 mm thick (square/ rectangular) polished, area of each tiles n.exc 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15mm thick rendering in cement mortar (1:4) and pointed in white or colour cement to match the colour of tiles complete all as specified. 35 Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. 36 M&L for 75mm thick cement concrete 1:3:6, type C-2, (using 40 mm graged stone aggregate) as in sub base of flooring over rammed earth complete all as specified and directed by Engr-in-charge. 37 M&L 25mm thick cement concrete flooring 1:2:4, type B0, using 12.5mm graded stone aggregate on roof slab complete all as specified and directed. 38 M & L PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in kerbs or mud stops, rounded or chamfered on edges and similar work all as specified and as directed. 39 M&L rendering 15mm thick water proofing plaster in CM 1:3 on slab/roof admixed including and with water proofing compound @ 200 ml per bag of cement. 40 Preparation of roof top surfaces, providing and applying UV stable single component smart care damp proof ultra is a fibre reinforced elastomeric liquid applied water proofing membrane formulated with PU hybrid polymers and reinforcing acrylics fibres and having SRI of 106 on top of concrete roof surface in three coats including self primer at ratio of damp proof and water 3:1 and coverage @ 1 Ltr/10 sqm with a thickness of 650 micron. Note : 6 Hrs interval between two coats will be maintain & the work will be carried out through company applicator duly got approved from accepting officer in writing before incorporation and paid only after receiving of the warranty certificate from the company. 41 S & F false ceiling not less than 9 mm thick gypsum tiles (600mm x 600 mm) laminated with PVC film on the face side & metalised polyester film on the back side with all four edges sealed with PVC film (shade either plain white or crack) fixed using T grid/Cross-T/Wall angle/level clip & suspenders/hangers 4 mm dia.GI wire (upto 1200 mm length) adjusting level fixed to roof slabs/trusses complete all as specified and as directed by Engineer-in-Charge. 42 Supply and fixing curtain rod 25mm dia MS pipe with coloured PVC coated, wall thickness of pipe not less than 20 guage, including fancy type brackets and pair of decorated end knobs (finials), stop roller etc. as per site requirement, fixed to wall with fixing accessories, including taking down old existing curtain rods any description complete all as specified and as directed by Engineer-in-Charge. 43 M&L for anti termite treatment for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. 44 M&L for anti termite treatment for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface complete all as specified and directed.Note : Area of the sub structure in contact with backfill to be measured. 45 M&L for anti termite treatment for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. 46 M&L for anti termite treatment for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. 47 M&L for anti termite treatment for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. 48 M&L for hardcore of broken bricks of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified. 49 M&L 50mm thick PCC 1:3:6, type C2, using 40 mm graded stone aggregate as in plinth protection in panel not more than 2.5m span, surface finished even smooth without using extra cement complete all as specified and directed. 50 Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface all as spd and directed by Engr-in-Charge.Note: Rate for making good shall be deemed to be included in above item rate. 51 M & L for point wiring complete with 1.5 Sqmm (Nominal area) PVC insulated multustranded fire retardant (low smoke unsheathed and multicore copper conductor cable with colour code ISI marked and including PVC concealed conduict ISI marked and conduit fittings for one light point/fan point/exhaust fan/Bell Point controlled by one switch including PVC insulated 1.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified Note : Cost of MS sunken box and bakelite sheet included in the rate. 52 All as per Ser item No 51.00 above but one three pin socket outlet 5 Amps on the independent board complete all as specified. 53 All as per Ser item No 51.00 above but one three pin socket outlet 5 Amps on the same board complete all as specified. 54 M&L for point wiring complete with 2.5 Sqmm (Nominal area) PVC insulated multistranded fire retardant low smoke unsheated and stranded copper conductor cable ISI marked in and including PVC concealed conduit medium quality and conduit fitting for 3 pin 15 amp multicore switch socket combination including PVC insulated 2.5 Sqmm single core copper earth wire to common earth and connected to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified. 55 S&F for one 3 pin socket outlet. 15 amps, independent, with cables 4.0 sqmm size and conduit fitting for 15 amp AC point multicore switch socket combination including PVC insulated 4.0 Sqmm single core copper earth wire to common earth and connected to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified. Note : Two round wire, one round earth wire and one round PVC conduit shall be measured as one unit. 56 S&F in replacement switch Piano type single pole one way 5 Amp,230 VAC supply complete all as specified and directed. 57 S&F in replacement socket two in one ,3 Pin 5 Amps 230 VAC supply complete all as specified and directed 58 S&F in replacement switch Piano type single pole one way 15 Amp on laminated sheet top cover complete all as specified and directed (Sheet top cover including in point wiring). 59 S&Fin replacement socket Piano type 6 Pin 16 amp, 230 VAC complete all as specified and directed. 60 Supply & fixing PVC Lamp holder suitable for and including batten fittings ,LED Electric lamp 9 Watt with backalite 20mm back plate complete all as specified & directed. 61 S&F for Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked complete all as specified and directed. 62 S&F in replacement and testing LED light fitting 1x18watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. 63 Supply and fixing LED luminaire 600 mm x 600 mm,36 watt, 220 V AC surfacetype with high efficiency PMMA diffuser soft glare free light complete with driver suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge. 64 S&F as MCB distribution board double Door of sheet metal Single pole and neutral 4 way with 200 amps rated bus bar240 volts complete all as specified and directed. 65 S&F distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 12 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed. 66 S&F sheet metal enclouser VTPN/HTPN DB having facility to fix MCCB incomer upto 100 Amps and MCB in outgoing , TPN 4 WayDistribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar,neutral links, door earthing , IP-43 Protection including making good disturbed surfaces after taking out old unsv DBcomplete all as specified and directed.. 67 S&F MCCB TPN(4 Pole), 63 Amps 415 Volts of breaking capacity 16 KA (Adustable thermal and adjustable magnetic release setting) complete taking out down old unserviceable one and making necessary connections as existing and cleaning the terminals with CTC soluations complete all as specified and directed. 68 S & F of MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 6 to 32 Amps B curve all complete all as specified and directed. 69 S & F of MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 40 Amps C curve complete all as specified and directed. 70 S &F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SPof capacity20 Amps C curve complete all as specified and directed.Note : Two run of wire, one round earth wire and one round PVC conduit shall be measured as one unit. 71 M&L sub main wiringof PVC FRLS insulated unsheathed two core 6 sqmm copper multi stranded conductor including one run of single core copper conductor of size 6.0 sqmm as earth wire drawing in concealed PVC conduitcompleteall as specified and directed. 72 Supply and fixing Wall mounting fans complete with 3 blades and accessories, 230 V, 400 mm sweep, 1500RPM Five star rated with brushless direct current motor (BLDC) as specified and recommended by manufacturer all as specified and directed by Engineer in Charge. 73 Supply installation, testing and commissiong of air cooling and heating split air conditioners 1.5 TR electric driven single phase AC supply with suitable refrigerant, 240 Volts 50 Hz, comprising of all components e.g. Outdoor condensing unit indoor blower unit, wall/roof mounting with suitable brackets as recommended by manufacturers confirming to Bureau of Energy Efficiency(BEE) of 5 Star rating, complete including copper piping of adequate size and of required length as recommended or directed duly insulated with suitable insulating material , plywood, moulded thermocoal etc initial charging of refrigerant eco friendly as specified and recommended by manufacturer all as specified and directed by Engineer in Charge. 74 Material and labour for sand cushioning, with dry and clean fine river sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.Note:- Punned thickness shall be considered for payment purpose. 75 Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed. 76 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed. 77 S & F 40mm dia Tubes, light grade, galvanised,with all fitting; laid in trenches/walls complete all as specified and directed.