Construction Of Room At Chinore Farm , Earth Work In Bulk Excavation By Mechanical Means (Hydraulic Excavator) Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge All Kinds Of Soil : , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres: All Kinds Of Soil : , Extra For Every Additional Lift Of 1.5 M Or Part Thereof In Excavation /Banking Excavated Or Stacked Materials. All Kinds Of Soil : , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc In Layers Not Exceeding 20Cm In Depth Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50Mt & Lift Upto 1.50M. , Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth And Curing Complete , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering All Work Up To Plinth Level 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size) , 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) , Cast-In-Situ Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level. 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Steel Reinforcement For Rcc Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing Inposition And Binding All Complete Above Plinth Level Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For :- Foundations, Footings, Bases Of Columns Etc. For Mass Concrete , Suspended Florrs, Roofs, Landings, Balconies And Access Platforms , Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillar, Pier, Abutments, Posts And Struts , Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide , Add For Plaster Drip Course/Grooves In Plastered Surface Or Moulding To R.C.C. Projections , Brick Work With Common Burnt Clay (Non-Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : , Extra For Brick Work In Super Structure Above Plinth Level Upto Floor V-Level. , Ceramic Glazed Tiles Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer- In-Charge, In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Frames And Trusses Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia And Length (Hold Fast Lugs Or With Dash Fasteners Shall Be Paid For Separately): , Cost For Dash Fastner/ Chemical Fastener, , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is: 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters. With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws- 35 Mm Thick , Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , 5.0 Mm Thick Glass Pane (Weighing Not Less Than 12.50 Kg/Sqm) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete. 250X10 Mm , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc. Complete. : 300X16x5 Mm , Providing And Fixing Bright Finished Brass Handles With Screws Etc. Complete : 125 Mm , Providing And Fixing Bright Finished Brass Hanging Type Floor Door Stopper With Necessary Screws, Etc. Complete , Providing And Fixing Factory Made Upvc White Colour Casement/ Casement Cum Fixed Glazed Door Comprising Of Upvc Multi-Chambered Frame, Sash And Mullion (Where Ever Required) Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length (Shape & Size According To Upvc Profile), Upvc Extruded Glazing Beads Of Appropriate Dimension, Epdm Gasket, Zinc Alloy (White Powder Coated) 3D Hinges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Multi Point Locking Having Transmission Gear, Cylinder With Keeps And One Side Key, G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws, Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Welded Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. (Single / Double Glass Panes And Silicon Sealent Shall Be Paid Separately). Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With Top Hung Ventilator With 3D And S.S. Friction Hinges (400 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 64 Mm, Sash 67 X 110 Mm & Mullion 67 X 80 Mm All Having Wall Thickness Of 2.3 ±. 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension.(Area Ofdoor Upto 2.50 Sqm) , Three Track Three Panels Sliding Window With Fly Proof S.S Wire Mesh (Two Nos. Glazed & One No. Wire Mesh Panels) Made Of (Big Series) Frame 116 X 45 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.75 Sqm) , Cost For Toughened Glass 12 Mm Thickness , Cost Of Galavanised Wire Mesh Of Average Width Of Aperture 1.4 Mm And Nominal Dia. Of Wire 0.63 Mm , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Vitrified Floor Tiles Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours And Shades, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Grouting The Joint With White Cement And Matching Pigments Etc. Complete Size Of Tile 600X600 Mm , Providing And Fixing On Wall Face Un-Plasticized Rigid Pvc Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. (I) Single Socketed Pipes 75 Mm Diametre , 110 Mm Diametre , Providing And Fixing On Wall Face Un-Plasticized - Pvc Moulded Fittings/Accessories For Un Plasticized Rigid Pvc Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion. Coupler 75 Mm , 110 Mm , Single Tee With Door 75X75x75 Mm , 110X110x110 Mm , Bend 87.5° 75Mm Bend , 110 Mm Bend , Shoe (Plain) 75 Mm , 110 Mm , Providing And Fixing Un-Plasticised -Pvc Pipe Clips Of Approved Design To Un-Plasticised - Pvc Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) And Making Good The Wall Etc. Complete. 75 Mm , 110 Mm , Providing And Fixing Of Floor Traps 110 Mm With Double Chrome Plated Cover One Grated And One Closed And All Other Fittings Required. , Cement Plaster (In Fine Sand) 12Mm Cement Plaster Of Mix: 1:6 (1 Cement : 6 Fine Sand) , 15Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix In 1:6 (1 Cement : 6 Fine Sand). , 6Mm Cement Plaster 6 Mm Cement Plaster To Ceiling Of Mix 1 : 3 (1 Cement : 3 Fine Sand) , Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers’ Specifications: Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coats Applied @ 0.90Litre/10Sqm Over An Under Coat Of Primer Applied @ 0.75Litre/10Sqm Of Approved Brand And Manufacture Sal Wood , Distempering With Dry Distemper Of Approved Brand And Manufacture (Two Or More Coats) And Of Required Shade On New Work, Over And Including Water Thinnable Priming Coat To Give An Even Shade , Exterior Finishing Finishing Walls With Water Proofing Cement Paint Of Required Shade On New Work (Two Or More Coats Applied @ 3.84 Kg/10Sqm) , French Spirit Polishing, Two Or More Coats On New Works Including A Coat Of Wood Filler , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe With Manually Controlled Device (Handle Lever), Conforming To Is:7231, With All Fittings And Fixtures Complete, Includingcutting And Making Good The Walls And Floors Whereverrequired: W.C. Pan With Isi Marked White Solid Plastic Seat And Lid. , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm Dia Cp Brass Single Hole Basin Mixer Of Approved Quality And Make, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:- (A) White Vitreous China Wash Basin Size 550X400 Mm With A 15 Mm Cp Brass Single Hole Basin Mixer , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260x350 Mm And 340X410x265mm Sizes Respectively. , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C Waste Fittings Complete: 18.28.1 Semi Rigid Pipe 18.28.1.1 32 Mm Dia , Providing And Fixing Mirror Of Superior Glass (Of Approved Quality) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing Oval Shape 450X350mm (Outer Dimensions) , Pe-Al-Pe Composite Pressure Pipes And Fittings Providing And Fixing Polyethylene- Aluminum- Polyethylene (Pe-Al Pe) Composite Pressure Pipes Conforming To Is: 15450, U.V. Stabilized With Carbon Black Having Thermal Stability For Hot And Cold Water Supply, Capable To Withstand Temperature Upto 80ºc, Including All Special Fittings Of Composite Material (Engineering Plastic Blend And Brass Inserts Wherever Required) E.G. Elbows, Tees, Reducers, Couplers And Connectors Etc.This Includes Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge: Internal Work Concealed With Clamps At 1.00 Meter Spacing Including Cutting The Chases And Making Good The Wall Etc. 1216 (16Mm Od) Pipe , 1620 (20Mm Od) Pipe , External Work Including Trenching And Refilling Etc. Complete 1620 (20Mm Od) Pipe , Providing And Fixing Gun Metal Non-Return Valve Of Approved Quality 25 Mm Nominal Bore , Providing And Fixing Rectangular High Density Polyethylene Water Storage Loft Tank With Cover, Conforming To Isi: 12701, Colour Of Opaque White Or As Approved By Engineer-In-Charge. The Rate Includes Making Necessary Holes For Inlet, Outlet & Over Flow Pipes. The Base Support I/C Fittings & Fixtures For Tank Shall Be Paid Separately. , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Bib Cock Of Approved Quality Conforming To Is : 8931 , Providing And Fixing 15 Mm Nominal Bore C.P. Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Is : 8931 , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Make Conforming To Is : 8931 , Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) With R.C.C. Top Slab With 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand (Zone- Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarsesand (Zone- Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size),Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floatingcoat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Carriage Of Materials By Mechanical Transport Including Loading, Unloading And Stacking Sand , Stone Aggregate , Bricks , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group C , Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Supplyand Fixing Modular Blanking Plate On The Existing Modular Plate And Switch Box Excluding Modular Plate As Required , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required. , Supplying And Fixing Suitable Size G.I Box With Modular Plate And Cover In Front On Surface Or In Recess,Including Providing And Fixing 6 Pin 5/6Amps Modular Socket Outlet And 5/6 Amps Modular Switch,Connection,Painting Etc. As Required. , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing Of 32 A 240 Volts Modular Mcb In Modular Box, On Surface Or In Recess, Complete With Connections, Testing And Commissioning Etc. As Required.(For 2.0 Tr A.C) , Supplying And Fixing 5 Amps. To 32 Amps.Rating 240 Volts C Series, Miniature Circuit Breaker Offollowing Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way , Double Door , Supplying And Fixing Of Following Ratings Of D.P Mcb 240 Volts C Series In The Existing Mcb D.B Complete With Connections,Testing And Commissioning Etc. As Required. 25 A D.P Mcb 10 Ka C Curve , 63 A D.P Mcb 10 Ka C Curve , Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. , Supply Installation Testing And Commissioning Of Ip:20 Aluminiumbatten 10W-12 W +- 1 W Led Surface Mounted 2 Ft. With System Lumen Efficacy Of 100 Lm/W And P.F >0.9 Thd <20% Cct 6500K,Cri 80 .The Led Should Have Life Of 50000 Burning Hours At L70.The Inputvoltage Shall Be 150 V To 270 V.The Fixture Should Have Inbuit Surge Protection Of 2Kv.Certification-Lm 79 And Lm 80.The Test Report Should Be From Govt. Approved Lab/Inhouse Nabl Lab. , Supply Installation Testing And Commissioning Of Ip:20 Aluminiumbatten 40 W +- 1 W Led Surface Mounted 4 Ft. With System Lumen Efficacy Of 100 Lm/W And P.F >0.9 Thd <20% Cct 6500K,Cri 80 .The Led Should Have Life Of 50000 Burning Hours At L70.The Inputvoltage Shall Be 150 V To 270 V.The Fixture Should Have Inbuit Surge Protection Of 2Kv.Certification-Lm 79 And Lm 80.The Test Report Should Be From Govt. Approved Lab/Inhouse Nabl Lab. , Supply Installation Testing And Commissioning Ofceiling Fan 3 Star Rated With Voltage Range 90 V To 300 V,Min. Air Delivery 212 Cmm,Service Value 5.3 Cu.M/Min/Watt,Aluminium Blades ,Including Wiring The Down Rods Of Standard Length(Upto 45 Cm)With 1.5 Sq.Mm Fr Pvc Insulated,Copper Conductor,Single Core Cable Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc As Required. 1200 Mm , Supply,Installation,Testing And Commissioning 320 Cu.M/Hr. Ac220-240Volts, 50 Hzexhaust Fan Made Out Of Abs Plastic Material With Inbuilt Thermo Cutoff Protection And Noise Level Not Exceeding 37 Dbof Following Sizes Including Connection Etc. Complete As Required . 300 Mm , Supplying And Laying Of 1 No. Dwc High Density Poly Ethylene Pipe Having Corrugation On Outer Wall And Plain Surface Inner Wall Conforming To Is: 14930 Part-1 And 2 Complete With Accessories For Protection Of 1.1 Kv Grade Under Ground Cable Directly In Ground At A Depth Of 50 Cm Including Excavation And Refelling The Trench Etc.As Required . 63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal) , Supplying And Laying Of 1 No. Pvc/Xlpe Insulated And Pvc Sheathed /Xlpe Power Cable Of 1.1 Kv Grade Of Following Sizes In The Existingcable Tray/ Rcc/Hume/Dwc/Stone Ware/Metal Pipe As Required. 3.0 C X 10 Sq.Mm A2xfy , Supply And Making End Termination With Double Brass Compression Gland And Aluminium Lugs For The Following Sizes Of Pvc Insulated And Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required 3.0Cx 10 Sq. Mm (22Mm)