Tender For Laboratory Maintenance work in Microfluidics lab IWUNB at CSIR AMRPI, Bhopal- 1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 2 All kinds of soil 3 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil 4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from naturalsources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 5 Centering and shuttering including strutting, propping etc. and removal of form work for :Columns, piers, abutments, pillars, posts and struts, footing. 6 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :: 1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) : 3 graded stone aggregate20 mm nominal size). 7 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer & paint using structural steel etc. as requiredIn gratings, frames, guard bar, ladder, railings, brackets, 10 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes 110 mm diameter 11 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler-----12.42.1.2 110 mm 12 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermalexpansion.Single tee with door 110x110x110 mm 13 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 12.42.5.2 110 mm bend 14 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. ---- Shoe (Plain) 110 mm Shoe 15 12 mm cement plaster of mix :1:4 (1 cement: 4 sand) 16 18 mm cement plaster in two coats under layer 12 mm thick cementplaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 17 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 18 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats 19 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 20 Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete inall respect as per the direction of Engineer-in-Charge. 21 Labour for shifting of machines,jungle clearance, junk clearance etc 22 Brick work with chimny brick of RAVI/KAVI/ SHREE/A D in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 23 Providing and applying multicoat synthetic plaster as per approved design, pattern texture in 2 mm thick on new plastered surface finished in proper line and level as directed by Engineer-in-charge in five coats consisting of composition of four order of application given as under includig all materials, labour and scaffoldings etc.1) Scrapping of the new surface and applying sealer primer mixed with water in the ratio 1:3 (part sealer primer : 3 part water) and applying by brush @ 0.25 kg/sqm.2) Applying levelling coat of spectrum rustic fine or equivalent with trwel as a putty finished to generate required texture by trowel.3) Applying third coat of synthetic plaster with trwel @ 2.5 kg/sqm finished to generate required texture by trwel.4) Applying two coats of exterior super fine pigmented acrylic wall coating as top coat @ 0.5 kg/sqm in two coats and colours as approved by Engineer-in-charge all up to a height of 10m. 24 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm 25 P/f Aluminum Partion in door/ window section in aluminum sectionpowder coated medium gauge with 4mm glass and particle board as per requirement and required sealing rubber including fitting with clip, rubber as required with screws, handles, Latch, hinges lock etc all fittings and fixtures as requiredand desired by E-in-C. 26 Supplying and filling stone dust/kopra, in trenches plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by Vibratory roller and watering, levelling etc complete 27 Providing and fixing 16 mm thickgranite Platform , mirror polished,premoulded and prepolished, machine cut for plateform,of required size,approved shade, black colour and texture laid over pink marble 16 mm thickjoints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish including providing and fixing of under cabinets with door of 16 mm thick ply board and mica 0.75 mm on front and balancing lamination on back and fittings of make Hettich/Haffle/blun. The partition of under cabinets shall be of pink marble of required thickness including all fittings and fixtures etc. complete 28 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box/celling rose and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C. 29 Wiring for circuit / submain wiring alongwith earth wire with the following size of FRLSPVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required 30 a) 2 X 1.5 Sq.mm + 1 X 1.5 Sq.mm earth wire. 31 b) 2 X 2.5 Sq.mm + 1 X 2.5 Sq.mm earth wire. 32 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (Make - BEC/Kissan/Kasta/ Supreme/ Sudhakar/ Reliance) 33 a) 20mm 34 b) 25mm 35 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including,connections but excluding modular plate etc. as required. 36 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 37 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6pin 15 / 16 & 5 / 6 amps modular socket outlet and 15 / 16 amps modular switch, connection, painting etc. as required. 38 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C Curve including connections, painting etc. as required. 39 Supplying and fixingfollwing modular Switch/Socket on the existing modular plate & switch box including connections excluding modular plate etc as required. 40 3 pin5/6 Amps Socket outlet 41 15/16 A switch 42 6 pin 15/16 A socket outlet 43 Supplyiong and Fixing following size/ Modular plate, GI box alongwith modular base & cover plate for modular switchesin recess ets as required 44 1/2 module 45 8 module 46 Supplying and Drawing of UTP 4 pair CAT 6 Cable in the executing surface recssed /Steel/PVC conduit,as required 47 1 run of Cable 48 Supplying and fixing of RJ-45 Computer socket outlet modular type with GIO box and modular plate i/c making connection etc. as reqd. 49 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 50 Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 51 Supplying,installation,testing and commissioning of prewired LED compact light fitting of following type complete with all accessories etc. recess/surface/panel/flase ceilingi/c connection with3 x 1.5 sq. mm FRLS PVC insulated copper conductor wire earthing etc. as reqd. 52 LED BETTEN fittings surface/recess mounted in 4 feet length, 20/22 W 4000 lumens , cuminous efficiency105 Lum//Watt, cool day lightCRI 80, CRCA body , IP20 life L 70, 40 K, PF>0.95, THD<10%with PC glossy diffueser suitable for short circuit & overvoltage cut offi/c connectionwith 1.5 sq. mm FRLS PVC insulated, copper conductor , single core cable & earthingcomplete etc. as reqd. 53 Supplying and fixing of LED Recess/surface mounted downlight18/20 watt with Lamp complete with connection and testing etc as required as per Havellsmodal no.LHEAABPIL1WO012or similar make like havells/ Crompton/philips/wipro)