Renovation Up-Gradation Of Quarter Guard Of 124 Bn Bsf (Now 182 Bn Bsf) At Jalalabad Under Shq Bsf Abohar ( Now Shq Bsf Fzr) (Sh Ei, Fans And Accessories); 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. GROUP-B 2 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required Group B 3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 4 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required 5 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required 6 Supplying and drawing following sizes of FRLS PVC insulated copper condutor, single core cable in the existing surface/ recessed steel/ PVC Conduit as required. i) 3 x 1.5 sqmm 7 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i) 20 mm 8 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. ii) 25 mm 9 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. iii) 50 mm 10 Supplying and fixing EME stepped type electronic fan regulator (socket type) on the existing switch box including connections etc. as required 11 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required i) 200 mm X 250 mm X 60 mm deep 12 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required i) 5/6 amps switch 13 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required ii) 3 pin 5/6 A socket outlet 14 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required 15 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 16 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required 17 Supplying and fixing brass batten/ angle holder including connection etc. as required 18 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i) 4 way (4 + 12), Double door 19 Supplying and fixing 5 A to 32 A rating 240/415 volts,C curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. i) Single pole 20 Supplying and fixing 5 A to 32 A rating 240/415 volts,C curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. iii) Triple Pole and neutral 21 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 22 Supplying and fixing of 250 mm sweep, 1250-1300 RPM non metallic exhaust fan suitable for single phase, 50 Hz, 230 volt AC supply in existing opening including connection etc as required. 23 Installation, testing and commissioning of LED batten tube light complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 24 Supply, installation, testing and commissioning of 10 watt LED tube fittings comprises of extruded channel in thermally conductive material ,high translucent serrated milky white diffusers used to get glare free and smooth light distribution, efficiency :100lm/w and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. 25 Supply, installation, testing and commissioning of 09 watt LED ceiling light panel aesthetically designed recessed mounted panel in a light weight plastic including body surface ring of suitable size and same make directly on ceiling including connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. 26 Installation, testing and commissioning of LED flood light complete with all accessories directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 27 Earthingwith G.I. earth pipe4.5mtr long x 40mm dia including accessories and providing masonary enclosure with cover platehaving locking arrangement and watering pipe etc. withcharcoalor coke and salt complete as required. 28 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 29 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required 30 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 31 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 32 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required 33 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 34 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required 35 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 36 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 37 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required