| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation in all kinds of soils and subsoils and to the required depth as may be directed except hard rock requiring blasting but inclusive of shoring, strutting and bailing out water wherever necessary, refilling the sides of foundation and basement with excavated earth in layers of 15cm thick well rammed, consolidated and depositing the surplus earth in places shown with an initial lead of 10 meters and initial lift of 2 meters and clearing, levelling the site etc., complete. (TNBP NO. 23 & 24) |
| 2 | Supplying and filling in foundation and basement with Stone Dust in layers, not exceeding 150mm thickness well rammed, watered and consolidated complying with relevant standard specification etc., complete. (TNBP NO. 24 & 25) |
| 3 | Supplying and filling the Well Gravel in layers, not exceeding 150mm thickness well rammed, watered and consolidated complying with relevant standard specification. |
| 4 | Plain Cement Concrete 1:4:8 (One of cement, four of M Sand and eight of aggregate) using 40mm gauge hard broken stone jelly for foundation inclusive of dewatering if found necessary, shoring, strutting, side shuttering, ramming, curing and laid in layers not more than 15cm thick etc., complete complying with standard specification. (TNBP NO. 28) |
| 5 | Plain Cement Concrete 1:5:10 (One of cement, five of M Sand and ten of aggregate) using 40mm gauge hard broken stone jelly for foundation inclusive of dewatering if found necessary, shoring, strutting, side shuttering, ramming, curing and laid in layers not more than 15cm thick etc., complete complying with standard specification. (TNBP NO. 28) |
| 6 | Reinforced Cement Concrete 1:1.5:3 (One of cement, one & half of M Sand and three of aggregate) using 20mm gauge HB stone jelly for all RCC items of works excluding centering, shuttering and also cost of reinforcement grill in position but including laying, curing and finishing etc., complete and also fixing fixtures like fan clamps in the RCC floor / roof slab wherever necessary, vibrating Charges etc., complete complying with standard specifications and as directed by the departmental officers. (TNBP NO. 30) |
| 7 | Foundation and Basement |
| 8 | Ground Floor |
| 9 | First Floor |
| 10 | Second Floor |
| 11 | Reinforced Cement Concrete 1:2:4 (One of cement, two of M Sand and four of aggregate) using 20mm gauge HB stone jelly for all RCC items of works excluding centering, shuttering and also cost of reinforcement grill in position but including laying, curing and finishing etc., complete and also fixing fixtures like fan clamps in the RCC floor / roof slab wherever necessary, vibrating Charges etc., complete complying with standard specifications and as directed by the departmental officers. (TNBP NO. 30) |
| 12 | Foundation and Basement |
| 13 | Ground Floor |
| 14 | Supplying, fabricating and placing Reinforcement Steel of high yeild strength ribbed bar of various diameter and grade confirming to IS1786 of reinforced concrete work.The workincluding decoiling, straightening, cutting, bending, fabricating and placing in position at all levels and floors including lead and lift according to drawings, specifications, etc complete. Supply and use of 18Gauge black annealed binding wire double fold to tie the bars in position, chairs pins, space bars, unauthorised laps which willnot be measured separately neither for payment nor for reconsilation and providing precast cement / pvc coverblocksfor main reinforcement to ensure specifiedcover and as directed. Steel and binding wire will be procured by the contractor at his own cost. (TNBP NO. 30 & 86) |
| 15 | Supplying and erecting Shuttering with necessary supports for Plane Surfaces such as RCC Column boxing, top & bottom slabs, sill slabs, sunshade with all cross bracings including strutting using silver oak (country wood) joists of size 10cm x 6.5cm spaced at about 90cm centre to centre etc., complete. (TNBP NO. 86 & 86A) |
| 16 | Supplying and erecting Centering for sides and soffits including supports and strutting for Plane Surfaces such as RCC Slabs, Rectangular Beams \"T\" or \"L\" Beams, Lintels, Bed Blocks, Staircase, Waist and Landing Slabs, Landing Beams, Canopy etc. with all cross bracings using Silver Oak (Country Wood) Joists of size 10cm x 6.5cm spaced at about 90cm centre to centre supported by Casurina Prop of 10cm to 13cm dia spaced at 75cm centre to centre etc., complete. (TNBP NO. 86 & 86A) |
| 17 | For Plane Surfaces |
| 18 | Column Centering |
| 19 | Brick Work in Cement Mortar 1:5 (One of cement and five of M Sand) using second class bricks of size 9\" x 4 1/2\" x 3\" including curing etc., complete complying with standard specification. (TNBP NO. 31) |
| 20 | Foundation and Basement |
| 21 | Ground Floor |
| 22 | First Floor |
| 23 | Second Floor |
| 24 | Brick Partition wall of 11cm thickness in Cement Mortar 1:3 (One of cement and Three of M Sand) using Fly Ash Bricks of size 230 x 110 x 75mm using hoop iron reinforcement if found necessary including curing etc., complete complying with standard specification. (TNBP NO. 31) |
| 25 | Ground Floor |
| 26 | First Floor |
| 27 | Second Floor |
| 28 | Plastering with Cement Mortar 1:5 (One of cement and five of M Sand) 12mm thick including centering, strutting, finishing and curing etc complete complying with standard specification. (TNBP NO. 56 & 57) |
| 29 | Plastering with Cement Mortar 1:5 (One of cement, five of M Sand) 20mm thick including centering, strutting, finishing and curing etc complete complying with standard specification. (TNBP NO. 56 & 57) |
| 30 | Plastering with Cement Mortar 1:3 (One of cement, three of M Sand) 10mm thick including centering, strutting, finishing and curing etc complete complying with standard specification. (TNBP NO. 56 & 57) |
| 31 | Plastering with cement mortar 1:3 (One of cement and three of sand) 20mm thick with water proofing compound at 2% by weight of cement including centering, strutting, finishing and curing etc complete in all floors complying with standard specification and as directed. |
| 32 | Plastering with cement mortar 1:3 (One of cement and three of sand) 20mm thick including centering, strutting, finishing and curing etc complete in all floors complying with standard specification and as directed. |
| 33 | Finishing the floor with Plain Cement Concrete 1:2:4(One of cement, two of M Sand and four of aggregate) of 50mm thick using 20mm and 12mm size hard broken granite stone jelly, including finishing the top, rubbed smooth, threading and curing etc., complete complying with standard specification. |
| 34 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 35 | Paving the floor with best quality Vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in Cement Mortar 1:3 (One of cement and three of M Sand) 20mm thick and top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works). |
| 36 | Paving the floor with Anti Skid Plain Ceramic Tiles of all colours of size 305 x 305 x 6mm laid over 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One of cement and three of M Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.4 Kg/ sqm etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works) |
| 37 | Dadooing the Walls with Colour Glazed Tiles with printed design of size 150mm x 150mm x 6mm of approved quality set in Cement Mortar 1:2 (One of cement and two of M Sand) 10mm thick and pointing with white cement using 0.4 Kg / m² including adding suitable colour pigments to suit the colour of tiles including finishing the joints neatly and curing etc., complete complying with standard specifications. (The tiles should be got approved by the SIDCO Engineers before use on the work). |
| 38 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 39 | Supplying and laying of Cement Concrete Paver Block using 1:1.2:2.4 concrete (One of cement, one point two of M Sand and two point four of aggregate) of shapes, colour and texture as approved by the Engineer having thickness of 80-100 mm and having a crushing strength of 40 W/sq mm over a M-Sand bedding. Each paver block unit to be placed firmly vibration to the paver block with suitable plate vibrators and vibrating the M-Sand into the joints till the M-Sand tops at the labour for fixing as per standard specification and as directed. (TNBP NO. 31) |
| 40 | Painting two coats with Exterior Emulsion Paint of approved quality over one coat of primer to give an even shade including scaffolding, curing etc., complete. The rate including all materials for putty, primer, emulsion paint and all labour charges and as directed by the SIDCO Engineers (The quality and colour of the emulsion, putty and primer shall be got approved from the Executive Engineer before use on work). (TNBP NO. 66A) |
| 41 | Painting two coats of newly plastered wall surfacewith ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, cleanremoval of dirt, and including two or more coat of putty complete complying with standard specification. |
| 42 | Painting with two coats of Cement Paint of approved quality and shade at all floors in two coats to give an even shade including scaffolding, curing etc., complete. The rate including all materials for putty, primer, emulsion paint and all labour charges and as directed by the SIDCO Engineers (The quality and colour of the emulsion, putty and primer shall be got approved from the Executive Engineer before use on work). (TNBP NO. 66A) |
| 43 | Weathering Course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the SIDCO Engineers. (TNBP NO. 46B) |
| 44 | Finishing the top of terrace floor with one course of Machine Pressed Tiles of size 230mm x 230 mm x 20mm of approved quality laid in Cement Mortar 1:3 (One of cement and three of M Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 45 | Supplying and filling brick jelly of 40mm sizeincluding labour charges etc., complete complying with standard specification and as directed by the departmental officers. |
| 46 | Water proofing: Surface Preparation Cleaning surface to make it free from all the unwanted things dust,and other contaminants and protrusions by means of Scrubber application etc directed by engineer in charge. If any cracks in roof area means that will be filled with sealing material. Bitumen Primer Application After getting proper Surface cleaning, applying one Coat of Oil Primer to enhance the bonding Prpoerties. APP Membrane Application Supplying and applying APP Polymer Modified Bituminous Membrane having 3 mm Thickness and reinforcement of Glass Fiber Fabric) by thermo fusion method Using an LPG gas Torch. The Joints at the overlaps to10 cm be sealed by thermo fusion method using LPG torch heat application.(Roof & Toilet ) |
| 47 | Supplying and fixing of stainless steel pipe made out of SS 321 grade 50mm Dia. With 1.65mm wall thick for staircase handrail including labour charges for cutting, welding and fixing with MS flats (excluding cost of flat) etc., as directed by the departmental officers. |
| 48 | Supplying and fixing Mild Steel Grills as per the design approved to doors, windows or ventilators using MS flats or square rods for inner and outer members including cost of steel & angles and labour for fixing in position etc., complete complying with standard specification and as directed by the SIDCO Engineers. |
| 49 | Supplying and Erecting Pull and Push Type Rolling Shutter, Manually Operated (up to 8 sqm. Area) with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc and as directed by the SIDCO Engineers.The colour and quality of paint should be got approval from the executive engineer before use. |
| 50 | Manufacturing , Supplying and fixing of M.S Steel doors of size 0.90m x 2.10m, single leave door shutter using MS Angles of size 40 x 40 x 6mm at 3.5Kg/mused for the door outer frame, MS Angle of Size 35 x 35 x 35mm at 2.60 Kg/m for the shutter outer frame and middle horizontal bar, MS flat 32 x 6mm at 1.50 Kg/m for 10 Nos horizontal stiffner and covered the shutter with MS Sheet 18g including furniture fittings such as MS hold fast-4nos, Heavy duty hinges-3nos, 250mm Tower Bolt MS aldrop 250mm x16mm including Painting with priming coat with red oxide inclusive of wrought and put up charges, transportation charges and inclusive of all other incidental charges as directed by the SIDCO Engineers etc., Complete. |
| 51 | Supplying and fixing in position of Solid Panel PVC Door Shutters (with Frame) using 19 Gauge 19mm MS square tubes for styles & outer frames and 15mm MS square tubes for top, lock & bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. The shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The overall size of styles shall be 50mm x 30mm. The overall size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The overall size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter including labour charges for fixing doors along with frames in position etc., complete and as directed by the SIDCO Engineers. |
| 52 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 53 | Drilling of 150mm dia Bore Well in Hard Rock Areas anywhere in Tamil Nadu including transportation to the work site in hard rock areas and developing the bore well. |
| 54 | Supply and delivery of 150mm dia PVC Casing Pipe including the cost of pipe, insering the pipe and labour charges etc. complete. |
| 55 | Bore cap for 150mm Casing Pipe using M.S. Flat of size 1 cm x 3 mm and M.S. Sheet on top with bolting arrangements for securing the cap in position (Bore caps with M.S. Couplings need not to be made) |
| 56 | Charges for developing the bore well with air compressor of 300 cfm. Capacity including transportation, labour and fuel charges for compressor as directedby officers and conducting yeild test by \"V\" notch method as directed etc., complete. |
| 57 | Supplyinglaying & jointing of 50mm Dia. PVC rigid pipes and specials of approved make and approved quality as per IS No.4985/2000 and IS 7834/87 or as per the latest revision. including necessary earth work excavation and laying the pipes to proper grade and alignment upto 2.00m depth jointing with PVC couplers and with necessary specials as directed with heavy duty solvent cement joints and testing to the required pressure including the conveyance of water upto 1km lead for filling during testing including cost of pipe and fixing of necessary specials jointing materials, labour for jointing the specials and refilling the trench as before after the pipes are laid & as directed by the above rate does not include cost of specials). |
| 58 | Supply and delivery ofvertical type Submersible Pumpsets of 50 lpm x 275m head confirming to IS 8034 and as amended from time to time with ISI marking with all accessories as follows. I) Motor should confirm to IS 9283/1979 and as amended from time to time. ii) Pumpset conform to IS 8034 and as amended from time to time with ISI marking. iii) The motor winding should be made from high conductivity annealed copper conductor PVC insulated winding wires conforming to IS 8783/78 and suitable for operation onsingle phase 300/440 volts 50 cycle A.C. power supply. The motor winding should be suitablefor DOL starting. iv) Pump should be capable of pumping water with high TDS one set will be stored as standbye.The pump directly coupled with continous rated 2880RPM squirrel cage motor |
| 59 | Supply of fully automatic air break DOL starter for 50 lpm x 275m head submersible pumpset with 1 setof ON/OFF indicating lamps. i) Under voltage release with no volt coil- 1 set, ii) Over load relay, iii) Push button switches, iv) Mounted on Ammeter, v) Air Break contact suitable for next standardhigher KW rating, vi) Dry running preventor betweenpanel board to the motor given under item No. 1 through starter. |
| 60 | Supply and delivery of 1.1 KV Grade 3 core 4 Sq.mm.PVC insulated and sheathed flat type copper cable conforming to IS 694/1190 to be laidin betweenpanel board to the motor given under item No. 1 through starter.betweenpanel board to the motor through starter. |
| 61 | Laying3 core 4 Sq.mm.PVC insulated and sheathed flat type coppercable as per IE rules from the panel board to the motorthrough starter |
| 62 | Jointing the3 core 4 Sq.mm.PVC insulated and sheathed flat type coppercable including the cost of jointing materials, lugs, cable clamp etc, complete |
| 63 | Labour charges for erection of Submersible pumpset in bore wellincluding fixing and jointing submersible cable with proper clamps upto the starter to required depthand also fixing of riser pipes to the depth valves erection clamps pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPIC switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capasiter single phasing preventor water level guard and laying and jointing the cables and twin earthing as per IE rules including providing bed blocks etc., complete testing the pumpset and trial run for 10 days. |
| 64 | Supply and fixing of TNEB meter Board suitable for 32Amps 3 phase service connection with 3 Nos 32 A fuse unit (500V) 32A Neutral limk and earth link (1\"\" x 1/8\"\") copper flat on TW plank of size 600mmx450mmx19mm with supporting TW reepers of 1\"\" thick on either side with painting with suitable bolts and nuts for fixing the TW planks on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit. |
| 65 | Supply and fixing of 3 phase 32A ariel fuse unit for 3 Nos 32A fuse unit (500V) on suitable 15\"\"x12\"\" TW board covered with 6mm thick Hylem sheet on suitable angle iron work on the tapping pole with necessary clamps |
| 66 | Supply and fixing of 32A TPN (Tripple pole with netural ) on metal clad switch on suitable angle iron frame work with MS cable entry boxes with earth connection |
| 67 | Supply and fixing of 4 pole MCB Isolaters of 40A capacity including all labour charges. |
| 68 | Supply and run off 4 of 7/20 PVC Sheathed Copper Wire. |
| 69 | Earthing as per PWD Standard with an earth electrode of 2.00mtrs class - BG.I Pipe of Dia of not less than 32mm complete with necessary masonry work. |
| 70 | Providing UPVC Pipes and specials as directed etc., complete. |
| 71 | 50mm diaUPVC Pipe |
| 72 | 32mm diaUPVC Pipe |
| 73 | 25mm diaUPVC Pipe |
| 74 | 32mm diaUPVC Tee |
| 75 | 25mm diaUPVC Tee |
| 76 | 32mm diaUPVC Coupler |
| 77 | 25mm diaUPVC Coupler |
| 78 | 32mm diaUPVC Elbow |
| 79 | 25mm diaUPVC Elbow |
| 80 | Providing UPVC specials as directed etc., complete. |
| 81 | 32mm diaUPVC NRV |
| 82 | 25mm diaUPVC NRV |
| 83 | 25mm diaUPVC MTA |
| 84 | 25mm diaUPVC FTA |
| 85 | 25mm diaUPVC Tap |
| 86 | 25mm diaUPVC Flange Set |
| 87 | UPVC Solvent Paste |
| 88 | Thread ball |
| 89 | Providing PVC Pipes and specials as directed etc., complete. |
| 90 | 50mm diaPVC Pipe |
| 91 | 50mm diaPVC Coupler (Long size) |
| 92 | 50mm diaPVC Bend |
| 93 | Providing following specials as directed etc., complete. |
| 94 | 50mm dia GM Gate Valve |
| 95 | 50mm dia GM Non Return Valve |
| 96 | MS Clampset |
| 97 | 50mm Dia. CI Adaptor |
| 98 | 50mm Dia. GI Pipe |
| 99 | 50mm Dia. Flange set |
| 100 | 50mm Dia. GI Bend |
| 101 | 50mm Dia. Coupling |
| 102 | Precasting and fixing in position of RCC precast slab of 100mm thickness in cement concrete 1:2:4 ( one of cement, two of Crushed stone sand and four of aggregate) using 20mm size hard broken machine crushed stone jelly including cost of moulding, laying, curing and finishing and pointing with CM 1:3, but excluding cost of grill in position etc., complete and as directed. |
| 103 | Supplying,fabriction and fixing in position of steel door 0.90m x 0.90m in single leaf as per instruction of the SIDCO Enginners including providing necessary hold fast fixing the farme and with locking srrangements incuding painting two coats with good quaiity paint over a primary coat of red;oxide etc.complete. |
| 104 | Supplying and fixing of15 mm dia C.P Long body Bip cock with wall flange with Aerator of Essco fittings (Model No.512) including cost of fittings , labour for fixing etc, all complete and as directed by the departmental officers., (The quality and brand of fittings should be got approved from Executive Engineer before use). |
| 105 | Supplying and fixing ofC.P Short body Bip cock with wall flange with Esscofittings (Model No.511) including cost of fittings , labour for fixing etc, all complete and as directed by the departmental officers., (The quality of fittings should be got approved from Executive Engineer before use) |
| 106 | Supplying,and fixing health faucet of plastic body with one meter tube with jet spray and wall hook of Esco fittings of model no. 547 and two way bibcock of esco fittings of model no.512A or its equivalent including cost of fittings and labour charge for fixings etc,all complete in all respects and as directed by the departmental officers.(the quality of fittings should be got approved from Executive Engineer before use. |
| 107 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 108 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). |
| 109 | Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) |
| 110 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation,sand filling and refilling charges etc. will be measured and paid separately in the cases where the pipe lines are proposed to laid Below Ground Level |
| 111 | 160mm dia PVC pipe |
| 112 | 110mm dia PVC pipe |
| 113 | Supplying and fixing of150mm x 100mm stone ware gully trap with iron grating over a bed of 150mm thick brick jelly concrete in CC 1:8:16 (One of cement eight of sand and sixteen of brick jelly) using 40mm size brick jelly and brick masonry chamber 115mm thick in cement mortar 1:5 ( One of cement and five of sand) and plastered with cement mortar 1:3 ( One of cement and three of sand) 12mm thick etc., all complete. |
| 114 | Supplying and fixing of PVC Nahani Trap not less than 75mm 4 way / 2 way (Superior variety) having minimum of water seal of 50mm confirm to relevant I.S. specifications with its latest amendments including resting on the bed of brick jelly concrete 1:5:10 (One of cement, five of sand of ten of 40 mm gauge brick jelly) etc., complete as directed by the departmental officers (The PVC Nahani Trap should be got approved from the EE before use) |
| 115 | Constructionof Inspection chamber 0ffollowing size with cement concrete 1:5:10(one of cement five of sand and ten ofbroken stone using 40mm gauge broken brickjelly 15cm thick for foundation and 23cm thick brick masonry in C.M. 1:5 ( One of cement and five of sand) using second class Fly ash bricks of size 230 x 110 x75 plastering with cement mortar 1:3 ( One ofcement and three of sand) 12mm thick on both sides top and bottom including earth work excavation RCC 1:2:4 ( One of cement two of sand and four of 20mm gauge hard broken stone)5cm thick precast cover slab excluding the cost and fabrication of reinforcement grills but including benching channeling fixing cover slab in position curing finishing etc., complete in all respects. |
| 116 | 60cmx60cmx45cm |
| 117 | 60cmx60cmx60cm |
| 118 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 119 | Supplying and fixing best approved best quality brass CP soap tray of size 150 x 100mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). |
| 120 | Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). |
| 121 | Supplying and fixing in position of best quality and approved variety of PVC Cylindrical Water Tanks of 1000 Litres capacity conforming to I.S.I. specifications with necessary inlets and outlets and overflow, cleaning pipe arrangements and labour charges for fixing in position etc., and properly fixed in the floor top as directed by the departmental officers. |
| 122 | Supplying and fixing in position of CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete complying with standard specifications. |
| 123 | Supplying and fixing PVC Ventilating shaft of 100mm dia with 3 metre height including cost of 100mm dia PVC Cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers. |
| 124 | Supplying and filling in foundation and basement with M-Sand in layers, not exceeding 150mm thickness well rammed, watered and consolidated complying with relevant standard specification etc., complete. (TNBP NO. 24 & 25) |
| 125 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such ascolumn footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which requireonly nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) |
| 126 | Supply and Fabrication of Steel gate with outer frame and shutter frame in MS angle of size 40mmx40mmx6mm and with MS flat 25mm x 25mm x 6mm and MS Sheet of 18 gauge including ventilating arrangements. |
| 127 | Conveyance of surplus earth to the places shown by the Engineer in charges including loading into lorries, conveying unloading from lorries and spreading as instructed by the Engineer incharge with 0 to 1 km etc., complete. |
| 128 | Supplying cutting and fixing of 10mm Acrylic sheet and 2mm Acrylic brown sheet and 24\"x24\" SIDCO Logo and National flag logo 36\"x24\" including scaffolding and conveyance to the site etc and as directed by departmental officers etc. complete. |
| 129 | Random Rubble Masonry in CM 1:3 (One of cement and three of sand) using new rough stones and bond stones for drains including simultaneous flush pointing, curing etc., complete. |
| 130 | White washing two coats with five screened shell lime and washing the plastered surface etc., complete. |
| 131 | Supplying and Fixing Steel Doors and windows including cost of welding and other furniture fittings etc., complete. |
| 132 | Painting oldIron work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 133 | Removing the old AC Sheet Roofing without roof timbers (or) truss etc., complete |
| 134 | Metal sheet roofing with Galvalume Colour Sheet of 0.47mm thick including fixing the galvanised sheets with galvanised work bolts, cup washers, joints clips etc., complying with standard specification. The rate including cost of galvanised roofing sheet, bolt and nuts, transporting, erection chages,tools and plants engaged and all other incidental charges etc.,complete and as directed by the SIDCO Engineers. |
| 135 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 5 points / Coil) Lower End |
| 136 | Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Lower End |
| 137 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Lower End |
| 138 | Supply and fixing of 1 no.6/16 A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End |
| 139 | Supply and run of 2 of 4sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4sq.mm copper wire and making good of the concealed portion with suitable colour |
| 140 | Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32 A 4 P MCB switch as incoming and 12 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Lower End |
| 141 | Supply and fixing of 6 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63 A 4 P MCB switch as incoming and 18 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Lower End |
| 142 | Supply and Run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copper wire with painting of suitable colour. |
| 143 | Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. |
| 144 | Supply and fixing of TNEB meter board suitable for 32A three phase service connection with 3Nos. 32A fuse unit (500V) 32A neutral link and earth link (1\"x1/8\"copper flat) on TW plank of size 600mmx450mmx19mm with supporting TW reepers of 1\" thick an eitherside with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and interconnection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1No 40 Amp 30 MA Four Pole RCD / RCCB (Lower End) with suitable necessary connection |
| 145 | Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2\" x 1-1/2\"x1/4\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units(500V),1No. neutral link, copper earth flat of size 1\"x1/4\" with interconnection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with 1No 63Amp 30MA Four Pole RCD/RCCB (LowerEnd) with suitable necessary connection with earth connection complete |
| 146 | Supply and Laying of 4 x 120 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good |
| 147 | Supply and clarnping of 4 x 120 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps |
| 148 | Supply and providing cable end termination of 4x120sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete |
| 149 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class\"B\" GI pipe of dia not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry |
| 150 | Supply and Fixing of 63A, 12 Way Fuse Distribution Board |
| 151 | Supply and Fixing of 300A fuse with enclosure box |
| 152 | Supply and fixing of 18W 4feet LED tube in suitable general purpose battern with connection complete |
| 153 | Supply and Laying of 4 x 25 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 154 | Supply and fixing of 30W LED street light fitting with LED (Lower end) with 25mm dia. GI pipe (class B) with 1 no.25mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting . |
| 155 | Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion |
| 156 | Supply and fixing of CO2 type fire extinguisher, as per International Standard and specifications (IS:15683), Ready to use condition.ISI Marked, Capacity: 4.5 kgs, complete as per standard specification and as directed by the SIDCO Officers. (Five years warranty) |
| 157 | Supply & Laying of 25mm X 6mm GI strip |
| 158 | Earth work open excavation for forming roads in all kinds of soils and subsoils and to the required depth as may be directed except hard rock requiring blasting but inclusive of shoring, strutting and baling out water wherever necessary,well rammed, consolidated and depositing theearth in places shown with an initial lead of 10 metres and initial lift of 2 metres and clearing, levelling the site etc., complete. |
| 159 | Providing and laying Granular sub-base (GSB) layer of 200mm compacted thickness with minimum CBR value 30 grading conforming to Table 400 - 1 of MOST compacting with vibratory Rollers of 80 to 100 KN static weight to not less than 98% of the maximum laboratory dry density as per IS : 2720 (Part b) and fine dressing to required grade and cross slope as shown in thedrawing or as directed by the Engineers including obtaining and transporting all matrials from approved quarry site to worksite with all lifts and lead by machanical transport,headload or anyother mode of transpotation, including labour, tools, equipment, safty measures, testing and incidentals necessary to complete the work as per Technical specification Cluase 401 of MORTH and as directed by Engineers. |
| 160 | Providing and laying WET MIX MACADAM Base Course of 250mm compacted thickness in two layers of 125 mm thick or else as specified on prepared sub base with graded stone aggregate using 0.396cum of 45.00-22.40mm graded metal, 0.528cum of 22.40-2.36mm graded metel and 0.396cum of 2.36mm graded metal and below including premixing the material with water at OMC in mechanical mix plant carriage of mixed materials by tippertrucks to paver site, laying in uniform layers with paver, spreading the mix for uniform thickness with mechanical paver to the specified grades and cross sections and compaction by 80 -100 KN vibratory roller to required density etc. including labour for attending the paver site, including hire charges and fuel charges for tipper trucks, paver finisher, vibratory rollers and all other tools and plants required and all other incidental charges etc., complete as per Clause 406 of MORTH and as directed by Engineer. |
| 161 | Providing and laying Prime coat over WMM surface using 6kgs of bitumen Emulson for 10 Sqm area including cost and conveyance of bituminous binder including labour charges for preparing the surface and applying the required quantity of bitumen as prime coat by bitumen sprayer etc., complete as per clause 502MOST specification. |
| 162 | Providing and laying Tack coat over WMM surface treated with priming coatusing 2.5kgs of bitumen Emulson for 10 Sqm area including cost and conveyance of bituminous binder including labour charges for preparing the surface and applying the required quantity of bitumen as tack coat by bitumen sprayer etc., complete as per clause 503 of MOST specification. |
| 163 | Providing and laying 50mm compactedthick Bituminous macadam using 0.42cum of 26.5 - 11.2 mm graded metal and 0.10cum of 11.20 - 2.80mm graded metal and 0.18cum of 2.80mm and below with 38 Kgs of bitumen for premixing10Sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregates to required temperature and mixing them in required temperature in central Hot mix plant 20-30 tons capacity conveying the mix by Tipper trucks to paver site, spreading the mix in required temperature for uniform thickness of 50mm with mechanical paver to the specified grades and cross sections and compaction by 8-10 T power roller to required density etc. including labour for loading bitumen into bitumen tank and metal to feeder unit, labour for attending the paver site etc. including hire charges and fuel charges for 20-30T CMP with bitumen boiler, tipper trucks, paver finisher, power rollers and all other tools and plants required during all other incidental charges excluding Tack Coatover WMM surface etc., complete asper specification using CMP. |
| 164 | Providing and laying 40mm compactedthick semi-dense bituminous concrete using 0.10cum of 11.20mm Graded IRC HBGmetal ,0.16cum of 6.70mm graded IRC HBG metal and 0.11cum of 2.80mm and below with 28 Kgs of bitumen for premixing per 10Sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregates to required temperature and mixing them in required temperature in central Hot mix plant 20-30 tons capacity conveying the mix by Tipper trucks to paver site, spreading the mix in required temperature for uniform thickness of 40mm with mechanical paver to the specified grades and cross sections and compaction by 8-10 T power roller to required density etc. including labour for loading bitumen into bitumen tank and metal to feeder unit, labour for attending the paver site etc. including hire charges and fuel charges for 20-30T CMP with bitumen boiler, tipper trucks, paver finisher, power rollers and all other tools and plants required during all other incidental charges etc. complete as per specification using CMP. |
| 165 | Supplying and laying 200mm dia NP3 class RCC Humepipe conforming to the relevant ISI standards including necessary earth work excavation for a width of 0.45m and a depth of 0.60m andprovimg a baseof 0.15m thick and jointing the RCC Hume pipe with collar in proper grade and alignment with required jointing materials and as per specification and refilling the trenche as before levelling the site complete and as directed for crossing water supply and EB lines. |
| 166 | Forming embankment in the side berms and subgrade of Road portion using earth to the places shown by the places including earth work excavation charges, loading in to the lorries conveying , unloading from lorries and spreading as instructed by the Engineer in charge with a lead of 0 to 1KM etc complete. |
| 167 | Providing Gravel soling for base & berms of specified thickness including cost and conveyance of gravel to site and stacking them to departmental gauge for pre-measurment including labour charges for spreading and watering with all leads for good water, consolidation by power roller rolling and other charges for the tools and plants engaged etc., complete complying with standard specification. (Payment will be made for consolidated thickness of well gravel only). |