}

Tender For Construction Work Of 01 Kasak And 01 Shag Building In Village Jayapur. - Csc Bhawan 2 Earthworkinexcavationbymechanicalmeans(Hydraulicexcavator) / Manual Means In Foundationtrenchesor Drains (Not Exceeding1.5 M In Width Or 10 Sqm On Plan), In, Varanasi-Uttar Pradesh

Rural Engineering Department has published Tender For Construction Work Of 01 Kasak And 01 Shag Building In Village Jayapur. - Csc Bhawan 2 Earthworkinexcavationbymechanicalmeans(Hydraulicexcavator) / Manual Means In Foundationtrenchesor Drains (Not Exceeding1.5 M In Width Or 10 Sqm On Plan), In. Submission Date for this Tender is 28-11-2024. Building Work Tenders in Varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

46180698
Tender For Construction Work Of 01 Kasak And 01 Shag Building In Village Jayapur. - Csc Bhawan 2 Earthworkinexcavationbymechanicalmeans(Hydraulicexcavator) / Manual Means In Foundationtrenchesor Drains (Not Exceeding1.5 M In Width Or 10 Sqm On Plan), In
Open Tender
Indian
Uttar Pradesh
Varanasi
28-11-2024

Tender Details

Construction work of 01 Kasak and 01 Shag building in village Jayapur. - CSC Bhawan 2 Earthworkinexcavationbymechanicalmeans(Hydraulicexcavator) / manual means in foundationtrenchesor drains (not exceeding1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 3 1:4:8(1 Cement: 4 coarsesand (zone-III)derivedfrom natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 4 Centeringand shuttering includingstrutting, proppingetc. and removal of form forFoundations,footings,basesofcolumns,etc.formass concrete 5 Columns, Pillars, Piers, Abutments, Posts and Struts 6 Lintels,beams,plinthbeams,girders,bressumers and cantilevers 7 Suspendedfloors,roofs,landings,balconiesandaccess platform 8 Providingandlayinginpositionspecifiedgradeofreinforcedcement concrete, excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources): 9 Reinforcedcementconcreteworkinwalls(anythickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments,postsand strutsetc. aboveplinthlevel up to floorfivelevel,excludingcostofcentering,shuttering,finishingand reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derivedfrom natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 10 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 11 Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :With F.P.S.(non modular) bricks 12 Earth work filling in plinth in Rooms By cartege up to 6 km distance I/C all material labour T&P proper complition to the work . As per Analysis 13 Reinforcedcementconcreteworkinbeams,suspendedfloors,roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 gradedstoneaggregate20 mm nominalsize derived from natural sources). 14 SteelreinforcementforR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. (Cold twisted bars ) 15 Steelworkweldedin builtup sections/framedwork,includingcutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Ingratings,frames,guardbar,ladder,railings,brackets, gates and similar works 16 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners,allnecessaryfittingscomplete,includingapplyingaprimingcoatof approved steel primer.Usingflats30x6 mm for diagonalbraces and central cross piece 17 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panels 18 Providingand fixing circular/Hexagonalcast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hackedfor properbonding,top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 19 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. 20 Cementconcreteflooring1:2:4(1cement:2coarsesand:4 graded stone aggregate)finishedwith a floatingcoat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 21 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conformingto IS: 15622, of approvedmake,in all coloursand shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 22 12mm thick plaster with 1:6 cement & F/sand of 1.25 FM minimum thickness not to be less than 10 mm I/C supply of all materials labour and T & P etc required for proper completion of work. 23 12mm thick Rough surfaceplaster with 1:6 cement & F/sand of 1.25 FM minimum thickness not to be less than 10 mm I/C supply of all materials labour and T & P etc required for proper completion of work. 24 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 25 Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishingthegroovecompleteasperspecificationsanddirectionofthe Engineer-in-charge :15 mm wide and 15 mm deep groove 26 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:Newwork(twoormorecoats)overandincludingwater thinnable priming coat with cement primer having VOC content less than50 gram/litre 27 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 28 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 29 S/ Fixing of information signboard 30 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface/recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required : Group A 31 Supplyingandfixingfollowingpianotypeswitch/socketonthe existing switch box/ cover including connections etc. as required : 5/6 amps switch 32 15/16 A switch 33 3 pin 5/6 A socket outlet 34 6 pin 15/16 A socket outlet 35 Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopperconductor,single corecableinsurface/recessedmediumclassPVCconduitas : 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 36 Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopperconductor,single corecableinsurface/recessedmediumclassPVCconduitas : 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 37 Providing andfixingfollowingcapacityTP&Ndisconnector fuse switchunitinsidetheexistingpanelboardwithISImarkedHRC fuses includingdrillingholesin cubiclepanel,makingconnections, etc. as required. 32 ATP&N 38 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMCBDBcompletewithconnections,testingand commissioningetc. as required. Single pole 39 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioningetc. as required. 40 A 40 Supplyingand laying 6 SWGG.I. wireat 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 41 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THDlessthan 10%, remoteor electronicregulatorunit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 42 Supply and fixing of LED tube light with batten suitable for upto 1x22 watt LED tube light fitting complete in all respect. CAT AAA 43 SHG 44 Earthworkinexcavationbymechanicalmeans(Hydraulicexcavator) / manual means in foundationtrenchesor drains (not exceeding1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 45 1:4:8(1 Cement: 4 coarsesand (zone-III)derivedfrom natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 46 Centeringand shuttering includingstrutting, proppingetc. and removal of form forFoundations,footings,basesofcolumns,etc.formass concrete 47 Columns, Pillars, Piers, Abutments, Posts and Struts 48 Lintels,beams,plinthbeams,girders,bressumers and cantilevers 49 Suspendedfloors,roofs,landings,balconiesandaccess platform 50 Providingandlayinginpositionspecifiedgradeofreinforcedcement concrete, excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources): 51 Reinforcedcementconcreteworkinwalls(anythickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments,postsand strutsetc. aboveplinthlevel up to floorfivelevel,excludingcostofcentering,shuttering,finishingand reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derivedfrom natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 52 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 53 Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :With F.P.S.(non modular) bricks 54 Earth work filling in plinth in Rooms By cartege up to 6 km distance I/C all material labour T&P proper complition to the work . As per Analysis 55 Reinforcedcementconcreteworkinbeams,suspendedfloors,roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 gradedstoneaggregate20 mm nominalsize derived from natural sources). 56 SteelreinforcementforR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. (Cold twisted bars ) 57 Steelworkweldedin builtup sections/framedwork,includingcutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Ingratings,frames,guardbar,ladder,railings,brackets, gates and similar works 58 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners,allnecessaryfittingscomplete,includingapplyingaprimingcoatof approved steel primer.Usingflats30x6 mm for diagonalbraces and central cross piece 59 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panels 60 Providingand fixing circular/Hexagonalcast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hackedfor properbonding,top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 61 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. 62 Cementconcreteflooring1:2:4(1cement:2coarsesand:4 graded stone aggregate)finishedwith a floatingcoat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 63 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conformingto IS: 15622, of approvedmake,in all coloursand shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 64 12mm thick plaster with 1:6 cement & F/sand of 1.25 FM minimum thickness not to be less than 10 mm I/C supply of all materials labour and T & P etc required for proper completion of work. 65 12mm thick Rough surfaceplaster with 1:6 cement & F/sand of 1.25 FM minimum thickness not to be less than 10 mm I/C supply of all materials labour and T & P etc required for proper completion of work. 66 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 67 Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishingthegroovecompleteasperspecificationsanddirectionofthe Engineer-in-charge :15 mm wide and 15 mm deep groove 68 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour:Newwork(twoormorecoats)overandincludingwater thinnable priming coat with cement primer having VOC content less than50 gram/litre 69 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 70 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 71 S/ Fixing of information signboard 72 Photografy 73 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required : Group C 74 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 75 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required : 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 76 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required : 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 77 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required : 5/6 A switch 78 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required : 3 pin 5/6 A socket outlet 79 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required : 15 Amper switch 80 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required : 15 Amper socket 81 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 82 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) : 4 way (4 + 12), Double door 83 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required : Single pole 84 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 85 Supply and fixing of LED Bulb Light suitable for up toon surface complete in all Respect .Sanctioned by S.E. RED.VNS Est 3dt.30.11.2018 86 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 87 Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixingthe pipe with clamps at 1.00m spacing. The including jointing of pipes and with one step CPVC solvent cement and the cost of cutting chases and making good the same includingtesting of joints complete as per direction of Engineer in charge. Concealed work, including cutting chases and making good the walls etcDSR.18.8 20 mm dia 88 Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixingthe pipe with clamps at 1.00m spacing. The including jointing of pipes and with one step CPVC solvent cement and the cost of cutting chases and making good the same includingtesting of joints complete as per direction of Engineer in charge. Concealed work, including cutting chases and making good the walls etc.S.I. No.18.832 mm dia 89 Providing and placing on terrace (at all f;oor levels) Polyethylene water storage tank, IS:12701 marked, wih civer and suitable locking arrangement and over flow pipes but without fittings and the base support for tank. S.I. No.18.48 90 Providing and fixing waterbcloset squatting pan (Indian type WC Pan) with 100mm sand cast iron P or S trap . 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device (handle lever) conformimng to IS :7231 with all fittings and fixturescomplete including cutting and making good the walls and floors whereever required.White Vitreous China Orissa Pattern WC pan of Size 580x440 mm with integral type foot rests .s.I. No-17.1.1 91 Supply and fixing of 75 mm dia pvc vent pipeincluding all complite. .material Extra Item 23(33) 92 Supply and fixing of 110 mm dia pvc sewer line I/C all material labour T&P proper complition to the work .material Extra Item 23(31) 93 Providing and fixing C.P. Brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. S.I. No. W/S 18.50 94 Providing and fixing C.P. Brass stop cock (concealed) of standard desig and of approved make conforming to IS:8931S.I. No. W/S 18.52 95 Providing and fixing C.P. brass angle valve of basin mixer and geyser point of approved quality conforming to IS:8931S.I. No.18.53

Key Value

Document Fees
INR 854 /-
EMD
INR 26040.0 /-
Tender Value
INR 13.02 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail