| 1 | Excavation in trenches n.exc 1.5 M wide and n. exc 1.5 M depth and getting out in hard/dense soil getting out complete all as specified and as directed. |
| 2 | Excavation in post holes (or similar holes) each n exc 0.5 cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n exc 25cm, watering and removing surplus soil to a distance n exc 50m and making good surface in hard and denseloose soil complete all as specified and directed. |
| 3 | Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete including necessary form work complete all as specified and as directed. |
| 4 | Material and labour for Plain cement concrete 1:2:4, type B2, using 40mmgraded stone aggregate as in in foundations, filling and mass concrete. all as specified and as directed. |
| 5 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and as directed. |
| 6 | Removing excavated soil to a distance exc 1.5Km andnot exc 5Km and deposited where as directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 7 | Supply and laying Reinforced cement concrete hume pipes class NP2, laid and jointed complete with one collar per length of pipe, dia 150 mm complete all as specified and as directed. |
| 8 | Material and Labour for PCC 1:3:6, type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm dia pipe complete all as specified and as directed. |
| 9 | Material and labour for hard core with granite broken stone of gauge not exceeding 63 mm, deposited, spread, and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface all as specified and as directed. |
| 10 | Material and labour for 100mm thick plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base to floor finished even and smooth including necessary form work all as specified and as directed. |
| 11 | Material and labour for 100mm thick plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring finished even and smooth including necessary form work complete all as specified and as directed. |
| 12 | Material and Labour for providing precast cement concrete type C1, 1:3:6 (20 mm graded stone aggregate) solid blocks exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and as directed. |
| 13 | Material and labour for precastPCC 1:3:6 Type C1 using 20 mm graded aggregate solid block masonrynot exceeding 10 Cm width(with plain or interlocking joints as directed), built in cement mortar 1:6 all as specified and as directed. |
| 14 | Material and Labour for rendering 15 mm thickin CM 1:4 on brick/concrete surface of walls, finished fair and even surface without using extra cement complete all as specified and directed. |
| 15 | Material and labour for preparation of new surfaces on wall and applying two coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistant, dirt resistant exterior paint of required shade(company depot tinted) with silicon additives @ 1.43 Litre/10 Sqm over and includingpriming coat of exterior primer applied @ 0.90 Litre per 10 Sqmover new surface complete all as specified and as directed. |
| 16 | Supply and fix structural steel work in tubular trusses including special shaped washer complete using ERW or induction butt welded tubes conforming to IS - 1161-1979 grade St.-240 all as specified and as directed. |
| 17 | Supply and fix mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with rivetted or bolted or welded attachment all as specified and as directed. |
| 18 | Material and labour for applying two coats of synthetic enamel paint over one coat ofred oxide primer on new steel surfaces over 10 cm wide or girth including preparation of surface etc., complete all as specified and directed. |
| 19 | Supply and fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 20 | Supply and fixing Pre-painted galvalume aluminum zinc coating GI based Plain sheet roofing with yield strength (550 MPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer\"s instructions throughthrough specialist agency and complete all as specified and as directed. |
| 21 | Supply and Fix PVC (SWR) half pipes trapezoidal shape 150mm at top and 110mm at bottom single socketed, in any length with rubber ring joints, fixed as gutter complete all as specified and as directed. |
| 22 | Supply and fix PVC pipe (SWR) single socketed in any length with rubber ring joint 110mm dia fixed to wall complete all as specified and as directed. |
| 23 | Supply and fix Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay),heavy,for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securingpurlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 24 | Taking down cement plastering on concrete or Brick works surface racking out joints, hacking for key , scrubbing down with water etc complete all as specified and as directed. |
| 25 | Material and labour for rendering 10mm thick in Cement Mortar 1:6 on fair faces of brick walls or on concrete surfaces, finished even and smooth,without using extra cement complete all as specified and directed. |
| 26 | Material and labour for preparation of newly plastered surfaces and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and as directed |
| 27 | M & L Preparation of old distempered and paintedsurfaces including washing, rubbing down and stopping by brooming down , scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of Distemper oil emulsion on wall surfaces. |
| 28 | Material and labour for preparation of old treated surfaces of ceiling and applying one coat of acrylic distemper complete all as specified and as directed. |
| 29 | Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams to rough finished surface of concrete for flat complete all as specified and as directed. |
| 30 | Material and labour for reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in as in beams, cantilever, lintels over 1.5M span etc complete all as specified and as directed. |
| 31 | Material and Labour forTMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9 mm dia or secured with clips complete all as specified and as directed. |
| 32 | Material and labour for TMT bars(CRS/HCR), 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 33 | Supply and fix door closer hydraulically regulated, designation No.3 universal type, of Aluminium (extruded section body)suitable for door shutters of 851 to 1000mm width and of weight between 61 to 80kg complete all as specified and as directed. |
| 34 | Supply and fix powder coated aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws etc. with and including 2 Nos handle in each door , hinges complete all as specified and as directed. NOTE: Glass panel shall be measured and paid separately. |
| 35 | Supply and fix aluminium powder coated frame for doors,windows, ventilators with one or more rebates with joint clip and using rubber beading etc complete all as specified and directed.Note:Glass panel/particle board panel filling shall be measured and paid separately. |
| 36 | Supply and Fixing 4 mm thick sheet glass ordinary quality in square not exceeding 0.5 Sqm in each pane for fixing in aluminium joinery with rubber gasket as specified and as directed. |
| 37 | Demolition of brick work / PCC block masonary built in cement mortar of any despciption and at any position complete all as specified and as directed. |
| 38 | Demolition of reinforced cement concrete of any description and in roof/landing/chajja/shelves and similar suspended work complete all as specified and directed. |
| 39 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) remaining serviceable tiles to stores and rubish off the premises all as specified and as directed. |
| 40 | Material and labour for glazed ceramic coloured tiles 350x250x7mm / 450x350x7mm in vertical surface such as dados, set and jointed in neat cement slurry over and including backing coat of 10mm thick in CM 1:4 complete all as specified and directed. |
| 41 | Material and Labour for Vitrified tiles 10mm thick (square/rectangular) area of each tile notexceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed of 15mm thick in CM 1:4 complete all as specified and as directed. |
| 42 | Supply and fix Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including necessary hangers6mm dia GI up to1200mm length adjusting level fixed to roof slab by means of cleats made out of FI 40x3mm size 60 cm long and expansion holdfast 12.5mm dia 40mm long with and including 10mm thick gypsum board fixed with screws after taking down existing unserviceable false ceiling system completely all as specified and as directed. |
| 43 | Material and labour for preparation of new false ceiling fibre/gypsum board surfaces, providing one or more coats of Birla white wall care putty to achieve smooth surfaces and applying two coats ofdistemper oil emulsion of approved shade/tint over a coat of compatiable priming paint complete all as specified. |
| 44 | Demolition of concrete surfaces in ground floor and paving n.exc. 15cm thickness (below or above ground level) complete all as specified and as directed. |
| 45 | Removing excavated soil to a distanceexc 250m and not exc 500m and deposited where as directed at a level not exc 1.5 m above the starting point, spreading and levelling complete all as specified and as directed. |
| 46 | Supply and fix 3mm thick polycarbonate solid sheetwith sealed end and fixed using aluminium profile section with rubber beading fixed with self driven screw and properly water proofed using silicon sealent with all accessories as in roof/cladding as per manufacturers instructions complete all as specified and as directed.Make: Lexan/Tuflite/Gallina/Sunlite |
| 47 | Material and labour for old surfaces on wall and applying one coats of 100% premium acrylic emulsion paint having VOC not less than 50 gm/lit and UV resistance as per IS 15489-2004, dust, alkali and fungal resistant, of approved shadewith silicon additives @ 1.43 lit/10Sqm complete all as specified and as directed. |
| 48 | material and Labour for shifting of DG Set 200 KVA from ICGS Jetty Vizhinjam to ICGS Station Vizhinjam after disconnecting the existing cable connection, earthing etc Unloading the DG Set at ICGS Vizhinjam Station near Pump house and re-fixing the same on the PCC Platform and necessary connection of LT Cables and Earthing complete. After installation of DG Set testing and commissioning on full load as per directed by Engineer-in-ChargeNOTE :-If any damage during the transportation the contractor shall repair the same without any extra cost. |
| 49 | Supply & Fix onload changeover switch heavy duty 315 Amps capcity, 4 pole 415 volts 50 Hz in standard sheet metal enclosure, powder coated, siemens grey colour and fixing complete all as directed by Engr-in-charge. Make: Indoasian Cat No:ICAS0320 or equivalent in Havells/Crompton Greaves/L&T/Standard |
| 50 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel stripor wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 240 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed. |
| 51 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel stripor wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 185 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed. |
| 52 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel stripor wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 120 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed. |
| 53 | Earthing with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized ironsteel all as shown in Electrical Plate No.5 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1(using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completionincluding taking out old earthing all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc., complete |
| 54 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtrwide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottomsurfaces to required level complete all as specified and directed. |
| 55 | Removing excavated soil and depositing to the sides and returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm thick in soft/loose soil after cable is laid complete all as specified. |
| 56 | Laying only High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches 40 mm bore complete all as specified and as directed.NOTE: HDPE will be provided by the department at site. |
| 57 | Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FR) upto and including working voltage 1100volts grade, drawn through and including non metallic rigidPVC conduit not less than 20mm drawn in concealed conduit in wall and open conduiton ceiling including all accessories ISI marked including factory made galvanised modular flush sheet metal enclosure having top bottom side and back wall knock out for conduit entry from any direction suitable to the approved make of switch/socket outlet conforming to IS 14772-2000 and suitable for for cover plates and unsheathed copper conductor stranded cable (FR) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:-(a) onelight point controlled by one switch 5 Amps |
| 58 | (b ) onefan pointpoint controlled by one switch 5 Amps |
| 59 | (c) One 3pin socket outlet 5 Ampson Independent board |
| 60 | (d ) One 3pin socket outlet 5 Ampsonsame board |
| 61 | All as per Item No. 58 above but with 4 sq mm PVC insulated copper conductor cable(FR) including 4 sq mmPVC copper conductor used as earth wirefor power point on independent board for One 3 pin socket outlet, 15 Amps. |
| 62 | Supply and fix Modular switch one way 6A, 1 Module complete all as specified and as directed. |
| 63 | Supply ans fix Modular socket combination 16 A, 6 pin, 3 module complete all as specified and directed. |
| 64 | Supply and fix wall mounting fan 450mm sweepsingle phase 230 volt connecting complete all as specified and as directed. Make:Havells /Usha/Crompton/Bajaj |
| 65 | Supply and fix MCB SP 6-32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole in the MCB DB,IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed. |
| 66 | Supply and fix MCB SPN 40 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 67 | Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommerDouble door, flush to wall complete all as specified and directed . |
| 68 | Material and labour for Sub main wiring using two runs of single corePVC insulated cable (FR) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size non metallic rigid PVC conduit not less than 25mm dia with accessories including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-3 run of 6 sqmm PVC copper wire and One run of PVC conduit shall be measured and paid as oneunit. |
| 69 | Supply and fix in replacement of Ceiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed. |
| 70 | Supply and fix LED tube light fitting 4 feet with tube decorative ultra slim round profile LED lighting fixtures 20 Watt with extruded polycarbonate, envirmental friendly energy efficient ready to use pack,accessoriesprewiredand connecting up complete all as specified and as directed.Make : Cat No. LHEXARP7UN1W020 of Havells or Equivalent in Crompton Greaves/Philips/Wipro |
| 71 | Supply and Fix Modular Socket, 6 A- 2/3 pin combined 2 module complete all as specified and as directed. |
| 72 | Supply and Fix switch socket combination 3 pin, 5 Amps, 230 volt AC with ISI marked flush type complete all as specified and as directed. |
| 73 | Supply and fix Modular fan regulator 120 W one way , 2 Module complete all as specified and as directed. |
| 74 | Supply only LED luminaire 600 mm x 600 mm,40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.Make: Havells Cat part No. PLANO2X2PLR42WLED840S or equivalent in Philips/Bajaj/Surya. |
| 75 | Supply and fix ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep min air delivery 210 CFM service value 6.00 BEE. Five Star rated with brushless direc current motor (BLDC) complete all as specified and as directed. |
| 76 | Supply, install and commissioning 1.5 TR capacity split type air conditioner, inverter type, 5 Star / ISEER -5.33 or as per latest BER norms, hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter,with copper tube condencing unit including provision of suitable bracket fixing arrangement, copper pipe of required length and insulation complete all as specified and as directed. Make: Daikin/Hitachi/LG/O General |
| 77 | Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed input supply between 170 to 250V with output stabilizer supply at 230 V with accuracy ± 2.5% of capacity 15 Ampere all as specified and as directed.Make: VG 500 of V Guard or Equalent in Blue star/Voltas |
| 78 | Supply and fix in repairs LED highbay light 150 watt energy saving environment friendly and robust LED luminaire with efficacy suitable for ceiling(Surface/suspened) IP65 complete all as specified and as directed. Make: Cat No.RADIOSOHB150WLED75760DBOPC of Havells or equivalent in Crompton Greaves/Philps/Bajaj |
| 79 | Schedule of Credit (Minus) Rs.1630.00NOTE: Bidder shall insert credit amount of Rs. 1630.00 as ratein Green field under Col-13. |