}

Tender For As & As To Quarter Master Shed At Main Gate,Dress Changing Area At Enc Band Complex And Provision Of Stainless Steelunit Name Board , Acs, Fans For Certain Naval Unitsat Visakhapatnam Under Ge(Nb)Vizag., visakhapatnam-Andhra Pradesh

Military Engineer Services has published Tender For As & As To Quarter Master Shed At Main Gate,Dress Changing Area At Enc Band Complex And Provision Of Stainless Steelunit Name Board , Acs, Fans For Certain Naval Unitsat Visakhapatnam Under Ge(Nb)Vizag.. Submission Date for this Tender is 20-11-2024. Shed Construction Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

46065716
Tender For As & As To Quarter Master Shed At Main Gate,Dress Changing Area At Enc Band Complex And Provision Of Stainless Steelunit Name Board , Acs, Fans For Certain Naval Unitsat Visakhapatnam Under Ge(Nb)Vizag.
Open Tender
Indian
Andhra Pradesh
Visakhapatnam
20-11-2024

Tender Details

Tender For As & As To Quarter Master Shed At Main Gate,Dress Changing Area At Enc Band Complex And Provision Of Stainless Steelunit Name Board , Acs, Fans For Certain Naval Unitsat Visakhapatnam Under Ge(Nb)Vizag.; 1 Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame)complete all as specified and directed. 2 Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal ofdebris and rubbish outside MD land as directed by the Engr-in-Charge. 3 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and disposal ofdebris and rubbish outside MD land complete all as directed by the Engr-in-Charge. 4 Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) complete all as specified and directed. 5 Rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. 6 Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in hard and dense soil complete all as specified and directed. 7 M&L for Plain Cement Concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. 8 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in hard and dense soil complete all as specified and directed. 9 Removing excavated materials exc 250 m but n. exc 500 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. 10 Removing excavated materials exc 1.5 Km but n. exc 5.00 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. 11 M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate as in foundation, plinth beams, bases of columns and mass concrete complete all as specified and directed by Engineer-in-Charge. 12 M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate as inColumns, pillars, piers, posts and struts etc.complete all as specified and directed by Engineer-in-Charge. 13 M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span etc.complete all as specified and directed by Engineer-in-Charge. 14 M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate as in chajjascomplete all as specified and directed by Engineer-in-Charge. 15 M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, desk slabs and in shelves. complete all as specified and directed by Engineer-in-Charge. 16 Use and waste of form work to formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to battercomplete all as specified and directed by Engineer-in-Charge.. 17 Use and waste offormwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves ,plinth beam including sup- ports, overhangs, etc. also splays between floors and beams, etccomplete all as specified and directed by Engineer-in-Charge. 18 Useand waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work n exc 200 mm thick ( horozontal or slopping) for rough finished surface flat or curved of concrete complete all as specified and directed by Engineer-in-Charge. 19 Useand waste offormwork to sides of pillars, posts, struts, piers, columns and stanchions flat or curved of concretecomplete all as specified and directed by Engineer-in-Charge. 20 Useand waste offormwork to flat surfaces of chullah hoods, chajjas,troughs and similar items including edges complete all as specified and directed by Engineer-in-Charge. 21 Useand waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizintal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified & directed by Engineer-in- charge 22 S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. 23 S & F high strength corrosion resistant TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed. 24 M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6complete all as specified and directed. 25 M&L for10 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. 26 M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. 27 M & L for 25 mm thick cement concrete (1:2:4) type B-0 using 12.5 mm gaded stone aggregate laid on RCC roof slab to make surface levelled for proper slope finish the surface even and fair complete all as specified and as directed. 28 M & L for 10 mm thick, screed bed as in roof in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement mixed with water proofing compound as per manufacturers instructions complete all as specified and directed. (Note: WPC shall be measured and paid seperately) 29 Supply only integral water proofing compound (ISI marked) complete all as specified and directed. 30 M&L for preparation of horizontal or vertical surfaces for water proofing treatment on existing cleaned non accessible RCC roof with the following specification and manufacturings instruction complete all as specified and as directed:-(a) Preparing and cleaning of fully dry surfaces as per IS3067-1966(b) Applying bitumen primer(85/25 grade)conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm by the same membrane manufacturer of density at 25°C, 0.87 to 0.89 kg / Liter and viscosity 70-160 cps shall be applied on the prepared surface.(c) Applying a layer of APP based polymeric membrance 3.0mm thick (minimum) weight 3.6Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application.The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. (d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane. 31 M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. 32 M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 33 M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. 34 M & L for 25 mm thick, plain cement concrete 1:2:4,type B-0 (using 12.5 mm graded stone aggregate)as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed. 35 M & L for 100 mm thick, plain cement concrete 1:4:8,type D-2 (using 40 mm graded stone aggregate)as in sub-base of flooring, etccomplete all as specified and directed. 36 M & L for 100 mm thick, Cement concrete 1:2:4, type B-2 (using 40mm graded stone aggregate) as in base of flooring/hard standing, etc, and finished the cement concrete surfaces even and smooth without using extra cement complete all as specified and directed. 37 M & L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound,Grade ‘A for 100mm thick floor complete all as specified and directed. 38 M & L for 75 mm thick,plain cement concrete1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. 39 M & L for Vitrified, designed, light shade coloured (light shade), tiles, 7 to 8 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors, etc and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6complete all as specified and directed. 40 All as per item no-39 here-in-before but fixed on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. 41 M&L for Non-Skid Ceramic coloured tiles 7 to 8 mm thick (Square/ Rectangular) polished, light shade, area of each tile Exc 0.11 Sqm butnot exceeding 0.18 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match. Including 15mm thick screed bed in CM 1:6 complete all as specified and directed. 42 M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors by providing 3 mm spacers and filling with epoxy grout of shade matching with tiles, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry complete all as specified and directed. 43 M & L for designer Chequered cement concrete tiles of size 30cm x 30cm x 23-25mm thick, as in floors etc,including 15 mm thick screed bed in cement mortar 1:6 and set & jointedin neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed. 44 M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc primer complete all as specified and as directed.. 45 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. 46 S & F MS steel work in tubular trusses including special shapedwasher etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and directed. 47 M & L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming toFe.290.Gde-E-165 (Brackets over 10 kg each to be measured under Structural Steel) complete all as specified and directed. 48 Dismantling Plain or corrugated steel sheeting,of any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed 49 S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturers instruction complete all as specified and directed. 50 M & L for cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed. 51 M&L for preparation of new platered surface of wall and applying two coats of oil bound distemperover a coat ofprimer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfacescomplete all as specified and as directed.Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS 52 M&L for preparation of new platered surface of wall and applying two coats of weather proof exterior acrylic emulsion paint havingdart pick up resistant,silicon enhanced,UV resistant and PU enhanced propertyover a coat of alkali resistant primer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfacesincluding all necessary saffolding, complete all as specified and directed.Note :-Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS 53 S & F Powder coated (minimum 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Note : (i)Thickness of aluminium section shall not be less than 1.5 mm). 54 S & F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screwsetc.complete all as specified and directed. 55 S&F of Powder coated aluminium (minimum thickness of powdercoating 50 micron) for shutters of doors, windows & ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fastenersof required dia and size, including necessary filling up the gapsat junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed 56 S&F Powder coated aluminium (minimum thickness of powdercoating 50 micron) work for doors, windows, ventilators andpartitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed 57 S & F 12mm thick fully glazed, toughened clear glass, cutting to proper shape and size, drilling and aligning for propper fixing and fitted with necessary fixing arrangementand all other necessary fittings and fixtures and mounting the edges with dry set neoprine/EPDM gasket complete all as specified and directed. 58 S & F 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty/ aluminium/ wooden beading in square exc 0.5 sq. m in each pane all as specified and directed. 59 S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed. 60 S & FSolar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturerscomplete all as specified and as directed. 61 Supply only 12 mm thick, Prelaminated particle board, exterior grade, prelaminated both side with decorative choice laminationfixed with screws to timber/metal frame work complete all as specified and directed. 62 S & F Floor door stopper of aluminium alloy body and tongue, anodised, 150 mm overall length of cover plate with hard drawn steel spring, fixed in floorcomplete all as specified and directed. 63 S & F Aluminium (Die cast) body door Closer hydraulically regulated, designation No 3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified and directed. 64 S & F100 mm, 4 lever, Brass, Mortice Lock, vertical type complete all as specified and directed. 65 M & L for post construction Antitermite treatment Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. 66 M & L for Antitermite treatment by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. 67 M & L for Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required of superficial area n.exc 150 Sq.cm complete all as specified and directed. 68 M & L for Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required of superficial area exc 150 sq.cm but n.exc 400 Sq.cm complete all as specified and directed. 69 Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise n.exe 100 sqcm and making good the disturbed surface complete all as specified and directed. 70 M & L for Mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. 71 M & L for 18 to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortor 1:6 & cutting, polishing complete all as specified and directed. 72 Supply and fixing of bold metallic stainless steel letters and alphabets made with SS plain sheet made out of 22 guage thick and 304 grade SS plain sheet of suitable width not less than 50mm and depth / thick not less than 20mm based on height of letter (hollow section made to shape by using computerized cutting), the height of letter/alphabet shall not be less than 15” in hindi and English languages and fixed on granite/MS/ACP wall cladding/tiled finished walls, elevated from the surface complete all as specified and as directed. 73 Preparation of new steel surfaces of any description over 10cm in width or girth, not otherwise described and applying two coats of PU paint (Polyurethane full gloss enamel paint) over a coat of epoxy zinc phosphate primer complete by using airless spray method complete all as specified and as directed 74 S & F aluminium composite panel sheet of 3mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30 micron fixed with suitableself tapping screws over frame work of anodised aluminium tubular section 25 x 50mm, 2mm thick, duly fixed to wall/ ceiling with expansion fastener, having panels not exceeding 1200 x 1200mm with necessary silicon filling in approved pattern/size as in column beam, wall etc compete all as specified and as directed.Note : Rate quoted is deemed to be included for necessary MS Scaffolding up to a height of 30m from the GL for carrying out of the job. Nothing shall be paid extra on this account. 75 M & L for conceledPoint wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLSH (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type includingmetal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLSH [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed,for one light/exhaust fan/fan point/call bellcontrolled by one way switch.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) 76 All as per item No. 75 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto 77 All as per item No. 75 above but for One 3/5 pin socket outlet 6 amps pointon same boardcomplete ditto 78 All as per item No. 75 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistrandedFRLSH (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cableFRLSH (ISI marked) as earth lead complete ditto 79 S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed. 80 S & F Modular socket outlet6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed. 81 S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed. 82 S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed. 83 S & F steped type modular fan regulator ,100/120 W 2 module complete all as specified and as directed. 84 S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. 85 Supply and fixing of LED Surface mounting general purpose LED Battens in extruded aluminium housingtube light fitting1x 20Watt with LED Lamp , driver including connecting upthree core1.00sq. mm copper conductor flexible wire/cable complete all as specified.Make : Model NoLUMILINEPLUSNEOBS20WLED830SPCSSIND of Havells or equivalent model of make list as given in PS as approved by GE 86 Supply and fixing LED light fittingmirror type with high output diffuser 2 feet, 10 watt, 220 V AC deocrative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat No LHEXACP7IN1W010 or its equivalent make of Philips / CG 87 Supply, fix, installation and commissioning BLDC ceiling fan of less noise, silent operation, light colour, conforming to IS-374-2019, 1200 mm sweep, 230 Volts, BEE 5 Star rating including all accessories such as down rod etc and connecting up with 1.5 Sqmm, PVC insulated, multistranded copper conductor cables from ceiling rose to fan complete all as specified and directed. (Note: Ceiling fan should have minimum 3 years manufacturers warranty)Make : USHA/Havells/Bajaj/CG 88 S & F Distribution Board, SPN 4 Way, 240V, Double door with IP 43 protection complete all as specified and as directed. (Make: Havells cat part No.DHDPSHODPW04 or equivalent make as per List of Manufacturers) 89 S & F Distribution Board, SPN 8 Way, 415V, Double door with IP 43protection, IK 09 complete all as specified and as directed. (Make: Havells cat part No. DHDPSHODPW08 or equivalent make as per List of Manufacturers mentioned in PS) 90 S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havells cat part No. DHDPSHODRW12 or equivalent make as per List of Manufacturers mentioned in PS) 91 S & F Distribution Board, SPN 6 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havells cat part No.DHDQSHODPWO6 or equivalent make as per List of Manufacturers mentioned in PS) 92 Supply, fixing, commissioning and testing MCB SPN 6-32A Amps, 240 Volts,10KA, C Curve complete all as specified and as directed (Make: Havells cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturers mentioned in PS) 93 Supply, fixing, commissioning and testing in repairs MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve,complete all as specified and as directed (Make: Havells cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturers mentioned in PS) 94 Supply, fixing, commissioning and testing MCB SPN 40 Amps, 240 Volts,10KA, C Curve complete all as specified and as directed (Make: Havells cat part No. DHMGCSNF040 or equivalent make as per List of Manufacturers mentioned in PS) 95 M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ]PVC insulated, unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (Medium grade) with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated, unseathed ,multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- (i) Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduitshall be measured as one length,(ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one ) 96 M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ]PVC insulated, unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (Medium grade) with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated, unseathed ,multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- (i) Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduitshall be measured as one length,(ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one ) 97 M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ]PVC insulated,unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated,unseathed, multi stranded FRLSH (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- (i)Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduitshall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one ) 98 S & F Exhaust fan, 600 mm sweep, heavy duty, metal body ,Minm RPM-900r/m, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in wallscomplete all as specified and directed Make : Havells, Model : Turbo Force Neo (FHEHDSPGRY24)or equivelant of make as per List of Manufacturers mentioned in PS 99 S & F Exhaust fan, 380 mm sweep, heavy duty, metal body ,Minm RPM-1400 r/m, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in wallscomplete all as specified and directed Make : Havells, Model : Turbo Force (FHEHDSPDB150)or equivelant of make as per List of Manufacturers mentioned in PS 100 S & F wall mounted high speed air circulator fan 600 mm sweep,1440 rpm, AC, single phase 240 Volts, 50 Hz, Aerodynamically designed blades, Sturdy close-mesh guardscomplete with all accessories and electric connection complete all as specified and directed Make : Havells, Model :FHACWSTSCL24 / Crompton,Model no : ACVORTEX 24 WM or equivalent model of Bajaj/Usha/ Khaitan/Orient as approved) 101 S & F high speed pedestral fan 450 mm sweep,1400 RPM , AC single phase 240 Volts ,50 Hz complete all as specified and directed Make : Crompton, Model : ACVORTEX18PF or equivalent model of Bajaj/Usha/ Khaitan/Orient/Havells as approved) 102 Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 Sqmm 2 core, laid in tranches complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) 103 Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. 104 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. 105 M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.(Note: Thickness after punning down shall be measured for payment) 106 Supplying and laying reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250mm x 150mm x 40mm complete all as specified and directed. 107 Supply and fixing 25 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor,tranches etc complete all as specified and directed. 108 Supply, installation and testing inverter split AC units indoor/outdoor complete with cordless remote control with inbuilt air ioniser and plasma filter for better indoor air quality, minimum 5 starrating,copper condenser,copper cooling coil and EER 3.2 of capacity 1.5 TR including 2.5 sqmm 4 core flex copper cable connection from indoor to outdoor unit as per site requirement including making holes of required diaonwalls and necessary masonry work for making gooddistrubuted surface and match with the existing colour complete all as specified. Note :- Copper pipe , insulation and connecting cable, angle iron bracket will be neasured and paid separately under respective itemMAKE:- Daikin / Hitachi / O- General / Voltas/LG/Carrier 109 Supply, installation and testing inverter split AC units indoor/outdoor complete with cordless remote control with inbuilt air ioniser and plasma filter for better indoor air quality, minimum 5 starrating,copper condenser,copper cooling coil and EER 3.2 of capacity 2.0 TR including 2.5 sqmm 4 core flex copper cable connection from indoor to outdoor unit as per site requirement including making holes of required diaonwalls and necessary masonry work for making gooddistrubuted surface and match with the existing colour complete all as specified. Note :- Copper pipe , insulation and connecting cable, angle iron bracket will be neasured and paid separately under respective item MAKE:- Daikin / Hitachi / O- General / Voltas/LG/Carrier 110 S & F voltage stabilizer of capacity 4 KVA, single phase, input working voltage 170-270 Volts, metal body with time delay system, wall mountable, built in thermal overload protection, low & high voltage cut-off protection, micro controller based design complete all as specified and directed.Make: V-Gaurd model no VG-400 or equivalent model of make mentioned in PS 111 S & F voltage stabilizer of capacity 5 KVA, single phase, input working voltage 170-270 Volts, metal body with time delay system, wall mountable, built in thermal overload protection, low & high voltage cut-off protection, micro controller based design complete all as specified and directed.Make: V-Gaurd model no VG-500 or equivalent model of make mentioned in PS 112 Supply and fixing copper pipe line heavy duty 1/2 diawith insulation,flair nuts as sunction/ discharge pipe of split AC complete all as specified and directed. 113 Supply and fixing copper pipe line heavy duty 1/4 diawith insulation,flair nuts as sunction/ discharge pipe of split AC complete all as specified and directed. 114 S & F MS stand for mounting outdoor unit of Tower Ac of capacity 1.5/ 2.00 Ton complete all as specified and as directed. 115 S&F 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed on wall for air condition water discharge pipe and connecting into rain water discharge pipe complete all as specified and directed 116 S & FUPVC cable trunking casing and capping of size 50x50 mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed. 117 S&F Socket Residual Current Device (SRCD) With Steel Enclosure two pin and earth plug including 20 Amps MCB SP complete all as specified and as directed(Make : Havells Cat Part No. DHDDCDP025202003 or equivelant model of make mention in PS)

Key Value

Document Fees
INR 500 /-
EMD
INR 93600.0 /-
Tender Value
INR 46.80 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail