| 1 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 3 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :100 mm dia pipe |
| 4 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore |
| 5 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W./ C.I. pipes including bed concrete as per standard design :100 mm diameter S.W./ C.I. pipe |
| 6 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :100 mm diameter |
| 7 | Providing and fixing soil, waste and vent pipes : 100 mm dia.of Sand cast iron S&S pipe as per IS: 1729. |
| 8 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 9 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore |
| 10 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100 mm dia pipe |
| 11 | Providing and fixing heel rest sanitary bend:100 mm dia- Sand cast iron S&S as per IS - 1729 |
| 12 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 100 mm dia Sand cast iron S&S as per IS - 1729 |
| 13 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet of Sand Cast Iron S&S as per IS: 1729. |
| 14 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 15 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 16 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 17 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour: 20mm nominal bore. Weighing not less than 40 gms. |
| 18 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore |
| 19 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work: 20 mm nominal outer dia. Pipes. |
| 20 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia .Pipes. |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia .Pipes. |
| 22 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. |
| 23 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 24 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 25 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand |
| 26 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars |
| 27 | Centering and shuttering including strutting, propping etc. and removal of form for :5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 28 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 29 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe: 32 mm dia |
| 30 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : 17.13.2 Orissa pattern W.C. pan of size 580x440 mm |
| 31 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete17.18.1 10 litre capacity - White |
| 32 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 33 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters :35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 34 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws: 35 mm thick shutters. with ISI marked M.S. pressed butt hinges bright finished of required size - Kiln seasoned and chemically treated hollock wood. |
| 35 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screwsKiln seasoned and chemically treated hollock wood 9.9.2.1 35 mm thick |
| 36 | Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 37 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 38 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 39 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. |
| 40 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of thickness 4 mm. |
| 41 | Dismantling and credit to Govt. By dismantling and taking away the doors, windows and clerestory window shutters( steel or wood) of area 3 sq. Metres and below including removal of all dismanted material from site of work its credit to contractorcomplete cleaning of site , dosposal of unservicable material, taking out, etc, all complete as per direction of engineer-in-charge. (dismantleddoors, windows and clerestory window shutters( steel or wood) and other dismantled fittings shall be the property of the contractor) |
| 42 | Dismantling and credit to Govt. By dismantling and taking away the Old PVC water storage tankincluding removal of all dismanted material from site of work its credit to contractorcomplete cleaning of site , dosposal of unservicable material, taking out, etc, all complete as per direction of engineer-in-charge |
| 43 | Dismantling and credit to Govt. By dismantling and taking away the old GI pipes 15 mmincluding removal of all dismanted material from site of work its credit to contractorcomplete cleaning of site , dosposal of unservicable material, taking out, etc, all complete as per direction of engineer-in-charge. (dismantledGI pipes and other dismantled fittings shall be the property of the contractor). |
| 44 | Dismantling and credit to Govt. By dismantling and taking away the old GI pipes 20 including removal of all dismanted material from site of work its credit to contractorcomplete cleaning of site , dosposal of unservicable material, taking out, etc, all complete as per direction of engineer-in-charge. (dismantledGI pipes and other dismantled fittings shall be the property of the contractor). |
| 45 | Dismantling and credit to Govt. By dismantling and taking away the old PTMT stock cock/float valve/bib cock/shower/pillar cock including removal of all dismanted material from site of work its credit to contractorcomplete cleaning of site , dosposal of unservicable material, taking out, etc, all complete as per direction of engineer-in-charge. |
| 46 | Dismantling and credit to Govt. By dismantling and taking away the old cast iron pipe all size including removal of all dismanted material from site of work its credit to contractorcomplete cleaning of site , dosposal of unservicable material, taking out, etc, all complete as per direction of engineer-in-charge. (dismantled Iron scrap and other dismantled fittings shall be the property of the contractor). |
| 47 | Dismantling and credit to Govt. By dismantling and taking away the old 10 ltrs capacity low level cistern PVC including removal of all dismanted material from site of work its credit to contractorcomplete cleaning of site , dosposal of unservicable material, taking out, etc, all complete as per direction of engineer-in-charge. |
| 48 | Dismantling and credit to Govt. By dismantling and taking away the Iron scrap(frame,grill,railing etc) including removal of all dismanted material from site of work its credit to contractorcomplete cleaning of site , dosposal of unservicable material, taking out, etc, all complete as per direction of engineer-in-charge. (dismantled Iron scrap and other dismantled fittings shall be the property of the contractor). |
| 49 | Dismantling and credit to Govt. By dismantling and taking away the old brass bib cock/stop cock/pillar cock/mixture of 15 mm dia including removal of all dismanted material from site of work its credit to contractorcomplete cleaning of site , dosposal of unservicable material, taking out, etc, all complete as per direction of engineer-in-charge. (dismantled Iron scrap and other dismantled fittings shall be the property of the contractor). |
| 50 | ELECTRICAL WORKS( SCHEDULE) (Srl No. 51 to 81 ) |
| 51 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required GROUP-B |
| 52 | Wiring for light / power plug with 4 x 4.0 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit along with 2 nos. 4.0 sq mm FRLS PVC insulated Cu conductor single core cable for loop earthing as required. |
| 53 | Wiring for light / power plug with 2 x 4 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit along with 1 no 4 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 54 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 55 | Supplying and drawing following sizes of FRLS PVC insulated copper condutor, single core cable in the existing surface/ recessed steel/ PVC Conduit as required. 3 x 1.5 sqmm |
| 56 | Supplying and drawing following sizes of FRLS PVC insulated copper condutor, single core cable in the existing surface/ recessed steel/ PVC Conduit as required. 3 x 4.0 sqmm |
| 57 | Supplying and drawing 4 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required |
| 58 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 59 | i) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 60 | ii) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 61 | iii)Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm |
| 62 | i) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch |
| 63 | ii) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 64 | iii)Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 65 | iv) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. T.v. socket outlet |
| 66 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 67 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 68 | I) Supplying and fixing of following way single pole and neutral, sheet steel MCB distribution board 240 V on surface / in recess complete with tinned copper bus bar, neutral bus bar, earth bar, dinbar,interconnections powder painted including earthing etc as required (But without/MCB/RCCB/ISOLATOR). 8 way double door |
| 69 | i) Supplying and fixing 5 A to 32 A rating 240/415 volts,\"C\" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. Single pole |
| 70 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp |
| 71 | Earthingwith G.I. earth pipe4.5mtr long x 40mm dia including accessories and providing masonary enclosure with cover platehaving locking arrangement and watering pipe etc. withcharcoalor coke and salt complete as required. |
| 72 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 73 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 74 | Add GST due to change 12 to 18 % (MF = 0.0633) on DSRItem ( Srl No. 51 to 73) |
| 75 | Providing and installation, testing and commissioning of MODULAR ceiling fan Regulator Rotary steptype and dismantling the existing complete etc. as required.Havells or equivalent make Havells/ Anchor/gold medal |
| 76 | Providing and fixing of 20 Watt, 6500K LED batten lighting fixture with extruded polycarbonate directly on ceiling/ wall, including connection with connector, testing and dismantling the existing complete etc. as required. Cat no LHEXACP7IN1W020 Havells(E-Lite LED Pride Plus Neo) make or equivalent model & specification in philips/Crompton-LDLSR-20-CDL/Bajaj |
| 77 | Providing and fixing of 60 watt LED Flood lightmade for energy saving, long life die-cast aluminium IP66 directly on the surface/wall including making connection, testing commissioning etc as required. Make Havells (JETA QUANTO PLUS) equivalent model and specification in Crompton/Bajaj/Philips. |
| 78 | Supplying, installation testing and commissioning of energy saving, 1200 mm sweep ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, includingproviding and fixing phenolic laminated sheet cover on the fan box etc. as required colour- White / Brown / Ivory etc as required. (make - Havells(Model - Samraat ES) or equivalent model in crompton /khaitan/Bajaj/CG/Oriant) |
| 79 | Providing and laying of 3.5 C x 35 sqmmone number PVC insulated and PVC sheathed / armoured XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Make- Havells/Polycab/KEI |
| 80 | Providing and laying of 3.5 x 35 sqmmone number PVC insulated and PVC sheathed / armoured XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Make- Havells/KEI/Polycab |
| 81 | Providing and laying of 3.5 C x 35 sqmmone number PVC insulated and PVC sheathed / armoured XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct/open laying as required. Make- Polycab/Havells/KEI |