Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-11-2024 | Corrigendum 1 | Date | 21-11-2024 |
| Sl. No. | Item Description |
| 1 | ACADEMIC GROUND FLOOR CIVIL |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 3 | All kind of Soil |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 5 | Ordinary Rock |
| 6 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) |
| 7 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor. |
| 8 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 10 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with common burnt clay non-modular bricks: |
| 11 | 1:4 (1 cement: 4 coarse sand) |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level |
| 13 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 14 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: |
| 15 | Cement mortar 1:6 (1 cement:6 coarse sand) |
| 16 | Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately) |
| 17 | All works upto Plinth level |
| 18 | All works above Plinth level upto floor V level |
| 19 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement 2 coarse sand 4 graded stone aggregate 12.5mm nominal size). |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 21 | Foundations, footings, bases of Columns |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 23 | Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 25 | Columns, Pillars, Piers, Abutments, Posts & Struts |
| 26 | Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level |
| 27 | Hot Rolled deformed bars |
| 28 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 29 | With F.P.S (Non-Modular) bricks |
| 30 | Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 31 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 32 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 33 | Second class teak wood |
| 34 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-in charge and panelling with panels of: (Note: screws shall be paid separately) Butt hinges and necessary |
| 35 | 12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked |
| 36 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid separately) |
| 37 | Second class Teak wood |
| 38 | 35mm thick shutters |
| 39 | Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge. |
| 40 | Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 41 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 42 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 43 | 100x75x4 mm |
| 44 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: |
| 45 | 250x16 mm |
| 46 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 47 | 200 * 10mm |
| 48 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 49 | 125 mm |
| 50 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 51 | Twin rubber stopper |
| 52 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 53 | Fixed to Opening / wooden frames with rawl plugs screws etc |
| 54 | Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse) |
| 55 | 25 mm thick |
| 56 | Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades. |
| 57 | 8mm thick (mirror polished and machine cut edge) |
| 58 | Granite stone of any colour and shade |
| 59 | Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with: |
| 60 | Udaipur green marble |
| 61 | Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand). |
| 62 | Dark shade pigment using ordinary cement |
| 63 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 64 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete |
| 65 | Size of Tile 600x600 mm |
| 66 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) |
| 67 | Size of Tile 600x600 mm |
| 68 | Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses. |
| 69 | 0.50 mm thick |
| 70 | Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 71 | Hot finished welded type tubes |
| 72 | 12 mm cement plaster of mix: |
| 73 | 1:6 (1 cement :6 Coarse sand) |
| 74 | 20 mm cement plaster of mix: |
| 75 | 1:6 (1 cement :6 Coarse sand) |
| 76 | 6 mm cement plaster of mix: |
| 77 | (1 cement: 3 fine sand) |
| 78 | Applying priming coat |
| 79 | With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood) |
| 80 | Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant. |
| 81 | Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content. |
| 82 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 83 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 84 | Painting with synthetic enamel paint of approval brand and manufacture to give an even shade es |
| 85 | Two or more coats on new work |
| 86 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: |
| 87 | New work ( Two or more coats) over and including priming coat with water thinnable cement primer |
| 88 | Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content less than 50 gm/litre, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour. |
| 89 | Two Coats |
| 90 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 91 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) |
| 92 | For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for separately) |
| 93 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15): |
| 94 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item) |
| 95 | With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 96 | Providing 10mm thick plaster of Paris (gypsum anhydrous) ceiling upto a height of 5m above floor level, over first class kail wood strips 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): |
| 97 | Flat surfaces |
| 98 | Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete |
| 99 | ACADEMIC FIRST FLOOR CIVIL |
| 100 | Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately) |
| 101 | All works above Plinth level upto floor V level |
| 102 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 103 | Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers |
| 104 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 105 | Columns, Pillars, Piers, Abutments, Posts & Struts |
| 106 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 107 | Hot Rolled deformed bars |
| 108 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 109 | With F.P.S (Non-Modular) bricks |
| 110 | Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 111 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 112 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 113 | Second class teak wood |
| 114 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary |
| 115 | 12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked |
| 116 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid seperately) |
| 117 | Second class Teak wood |
| 118 | 35mm thick shutters |
| 119 | Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge |
| 120 | Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 121 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 122 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 123 | 100x75x4 mm |
| 124 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: |
| 125 | 250x16 mm |
| 126 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 127 | 200 * 10mm |
| 128 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 129 | 125 mm |
| 130 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 131 | Twin rubber stopper |
| 132 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 133 | Fixed to Opening / wooden frames with rawl plugs screws etc |
| 134 | Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse) |
| 135 | 25 mm thick |
| 136 | Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with: |
| 137 | Udaipur green marble |
| 138 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 139 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete |
| 140 | Size of Tile 600x600 mm |
| 141 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) |
| 142 | Size of Tile 600x600 mm |
| 143 | Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses. |
| 144 | 0.50 mm thick |
| 145 | Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 146 | Hot finished welded type tubes |
| 147 | 12 mm cement plaster of mix: |
| 148 | 1:6 (1 cement :6 Coarse sand) |
| 149 | 20 mm cement plaster of mix: |
| 150 | 1:6 (1 cement :6 Coarse sand) |
| 151 | 6 mm cement plaster of mix: |
| 152 | (1 cement: 3 fine sand) |
| 153 | Applying priming coat |
| 154 | With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood) |
| 155 | Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant. |
| 156 | Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content. |
| 157 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 158 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 159 | Painting with synthetic enamel paint of approval brand and manufacture to give an even shade es |
| 160 | Two or more coats on new work |
| 161 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: |
| 162 | New work ( Two or more coats) over and including priming coat with water thinnable cement primer |
| 163 | Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content less than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour. |
| 164 | Two Coats |
| 165 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 166 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately)For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately) |
| 167 | For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately) |
| 168 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15): |
| 169 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item) |
| 170 | With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 171 | Providing 10mm thick plaster of paris (gypsum anhydrous) ceiling upto a height of 5m above floor level, over first class kail wood strips 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be pald separately): |
| 172 | Flat surfaces |
| 173 | COMPOUND WALL PART A |
| 174 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m. |
| 175 | All Kinds of soil |
| 176 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level |
| 177 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 178 | Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable seperately) |
| 179 | All works upto Plinth level |
| 180 | All works above Plinth level upto floor V level |
| 181 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 182 | Foundations, footings, bases of Columns |
| 183 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 184 | Hot Rolled deformed bars |
| 185 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 186 | With FPS( Non-Modular) bricks |
| 187 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 188 | Second class teak wood |
| 189 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary |
| 190 | 12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked |
| 191 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately) |
| 192 | For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately) |
| 193 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15): |
| 194 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item) |
| 195 | With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 196 | 15 mm cement plaster on the rough side of single or half brick wall of mix: |
| 197 | 1:4 (1 cement :4 fine sand) |
| 198 | Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content. |
| 199 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 200 | Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content less than 50 gm/litre, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour.Two Coats |
| 201 | Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 202 | Hot finished welded type tubes |
| 203 | COMPOUND WALL PART B |
| 204 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m. |
| 205 | All Kinds of soil |
| 206 | Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable seperately) |
| 207 | All works upto Plinth level |
| 208 | Providing and fixing G.I Chain Link Fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-Charge |
| 209 | Made of G.I wire of dia 4mm |
| 210 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 211 | Providing and Fixing Barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. |
| 212 | WATER BOUND MACADAM (W.B.M) ROAD |
| 213 | Excavation in Soil using Hydraulic Excavator and Tippers with Disposal upto 1000 metres. Unit Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and across sections, and transporting to the embankment location within all lifts and lead upto 1000m |
| 214 | Compacting Original Ground Arounds Loosening of the ground upto a level of 500 mm below the sub grade level, watered, graded and compacted in layers to meet the requirement of table 300-2 for sub-grade construction |
| 215 | Compacting Original Ground supporting sub-grade |
| 216 | Compacting Original Ground supporting Embankment |
| 217 | Construction of granular sub-base by providing granular material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 |
| 218 | By Mix in Place Method |
| 219 | Granular Sub-Base Grading-I Material |
| 220 | Granular Sub-Base Grading-II Material |
| 221 | Granular Sub-Base Grading-III Material |
| 222 | Water Bound Macadam |
| 223 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregate, watering and compacting to required density |
| 224 | By Manual Means |
| 225 | Grading II |
| 226 | Using Screening Crushable type such as Moorum or Gravel |
| 227 | Grading III |
| 228 | Using Screening Crushable type such as Moorum or Gravel |
| 229 | Prime Coat |
| 230 | Prime Coat over WMM / WBM |
| 231 | Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sum using mechanical means. |
| 232 | Tack Coat |
| 233 | Tack Coat on Bituminous surfaces |
| 234 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sum on the prepared bituminous surface cleaned with mechanical broom. |
| 235 | Bituminous Macadam Grading -I |
| 236 | Providing and laying bituminous macadam with higher capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction |
| 237 | Bituminous Macadam Grading -II |
| 238 | Providing and laying bituminous macadam with higher capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction |
| 239 | Surface Dressing |
| 240 | Providing and laying surface dressing as wearing course in single coat using crushed stone aggregates of specified size on a layer of bituminous binder laid on prepared surface and rolling with 8- 10 tonne smooth wheeled steel roller |
| 241 | 13 mm nominal chipping size |
| 242 | Seal Coat Description Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats |
| 243 | Type A |
| 244 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete: |
| 245 | 600mm dia R.C.C. Pipe |
| 246 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level |
| 247 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 248 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 249 | With FPS( Non-Modular) bricks |
| 250 | 12 mm cement plaster finished with floating coat of neat cement of mix |
| 251 | 1:4 (1 cement :4 Fine sand) |
| 252 | UNDER GROUND TANK |
| 253 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 254 | All kind of Soil |
| 255 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials. |
| 256 | All Kinds of soil |
| 257 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials. |
| 258 | Ordinary or Hard Rock |
| 259 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with common burnt clay non-modular bricks: |
| 260 | 1:4 (1 cement: 4 coarse sand) |
| 261 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 262 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 263 | Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately) |
| 264 | All works upto Plinth level |
| 265 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 266 | Foundations, footings, bases of Columns |
| 267 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 268 | Hot Rolled deformed bars |
| 269 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) |
| 270 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design. |
| 271 | With 20 mm diameter round bar |
| 272 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. |
| 273 | LD-2.5 |
| 274 | Rectangular shape 600x450mm internal dimensions |
| 275 | LANDSCAPING WORK |
| 276 | Planting of Trees and their Maintenance for one Year |
| 277 | Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year |
| 278 | Tree Guard with MS Angle Iron and Steel Wire |
| 279 | Providing and fixing tree guard 0.60 metre square, 2.00 metre high fabricated with MS angle iron 30 x 30 x 3 mm, MS iron 25 x 3; mm and steel wire3 mm dia welded and fabricated as per design in two halves bolted together |
| 280 | SEPTIC TANK 1 |
| 281 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 282 | All kind of Soil |
| 283 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 284 | Ordinary Rock |
| 285 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level |
| 286 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 287 | Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement. |
| 288 | 1:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size) |
| 289 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 290 | Hot Rolled deformed bars |
| 291 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 292 | With F. P. S. (non-modular) bricks |
| 293 | 12 mm cement plaster finished with floating coat of neat cement of mix |
| 294 | 1:4 (1 cement :4 Fine sand) |
| 295 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) |
| 296 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: |
| 297 | Inside dimensions 600x850 mm and 45 cm deep for single pipe line. |
| 298 | With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 |
| 299 | SEPTIC TANK 2 |
| 300 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 301 | All kind of Soil |
| 302 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 303 | Ordinary Rock |
| 304 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level |
| 305 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 306 | Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement. |
| 307 | 1:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size) |
| 308 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 309 | Hot Rolled deformed bars |
| 310 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 311 | With F. P. S. (non-modular) bricks |
| 312 | 12 mm cement plaster finished with floating coat of neat cement of mix |
| 313 | 1:4 (1 cement :4 Fine sand) |
| 314 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) |
| 315 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: |
| 316 | Inside dimensions 600x850 mm and 45 cm deep for single pipe line. |
| 317 | With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 |
| 318 | SEPTIC TANK 3 |
| 319 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 320 | All kind of Soil |
| 321 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 322 | Ordinary Rock |
| 323 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level |
| 324 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 325 | Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement. |
| 326 | 1:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size) |
| 327 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 328 | Hot Rolled deformed bars |
| 329 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 330 | With F. P. S. (non-modular) bricks |
| 331 | 12 mm cement plaster finished with floating coat of neat cement of mix |
| 332 | 1:4 (1 cement :4 Fine sand) |
| 333 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) |
| 334 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: |
| 335 | Inside dimensions 600x850 mm and 45 cm deep for single pipe line. |
| 336 | With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 |
| 337 | RAINWATER HARVESTING |
| 338 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 339 | All kind of Soil |
| 340 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level |
| 341 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 342 | 12 mm cement plaster finished with a floating coat of neat cement of mix: |
| 343 | 1:3 (1 cement :4 fine sand) |
| 344 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 345 | With FPS( Non-Modular) bricks |
| 346 | Providing and fixing P.V.C. Rain water pipes of 160 mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, including fixing the pipe on wall using approved wooden cleats projecting 25 mm to 40 mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C.fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 347 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 mm to 40 mm from face of wall a fixing with clips of approved quality and One Number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 years or any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 348 | DEMOLITION AND RETROFITTING WORK OF EXISTING BLOCK |
| 349 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge. |
| 350 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Charge. |
| 351 | In cement mortar |
| 352 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: |
| 353 | Of area 3 sq. metres and below |
| 354 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, racking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish of the dumping ground, all complete as per the direction of Engineer-in-charge |
| 355 | With cement mortar 1:4 (1 cement: 4 fine sand) |
| 356 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 357 | For thickness of tiles 10 mm to 25 mm |
| 358 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 359 | With FPS( Non-Modular) bricks |
| 360 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete |
| 361 | Size of Tile 600x600 mm |
| 362 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) |
| 363 | Size of Tile 600x600 mm |
| 364 | Painting with synthetic enamel paint of approval brand and manufacture to give an even shade es |
| 365 | Two or more coats on new work |
| 366 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: |
| 367 | New work ( Two or more coats) over and including priming coat with water thinnable cement primer |
| 368 | Providing and laying in-situ / ready mix M25 grade RCC jacketing work around the existing COLUMN, BEAM, SLAB etc.complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with fine aggregates of required specifications ( VSI sand finely washed etc ), height of 8 to 10 meter) |
| 369 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 370 | Hot Rolled deformed bars |
| 371 | PLUMBING GROUND FLOOR |
| 372 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 |
| 373 | 15 mm nominal bore |
| 374 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require: |
| 375 | White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 376 | Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 377 | W.C. pan with ISI marked black solid plastic seat and lid |
| 378 | Providing and fixing white vitreous China flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: |
| 379 | Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 380 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 381 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 382 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. |
| 383 | Rectangular shape 453x357mm dia. |
| 384 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge |
| 385 | Concealed work, including cutting chases and making good the walls etc. |
| 386 | 20 mm nominal outer dia Pipes |
| 387 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge |
| 388 | External work |
| 389 | 40 mm nominal outer dia Pipes |
| 390 | 50 mm nominal outer dia Pipes |
| 391 | Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete |
| 392 | Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. |
| 393 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. |
| 394 | With common burnt clay F.P.S ( non-modular )bricks of class designation 7.5 |
| 395 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore |
| 396 | Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with watertight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
| 397 | 100x100 mm size P type |
| 398 | With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 |
| 399 | PLUMBING FIRST FLOOR |
| 400 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 |
| 401 | 15 mm nominal bore |
| 402 | Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 403 | W.C. pan with ISI marked black solid plastic seat and lid |
| 404 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require: |
| 405 | White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 406 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 407 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 408 | Providing and fixing white vitreous China flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: |
| 409 | Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 410 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. |
| 411 | Rectangular shape 453x357mm dia. |
| 412 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge |
| 413 | Concealed work, including cutting chases and making good the walls etc. |
| 414 | 20 mm nominal outer dia Pipes |
| 415 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge |
| 416 | External work |
| 417 | 40 mm nominal outer dia Pipes |
| 418 | 50 mm nominal outer dia Pipes |
| 419 | Providing and fixing 75mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete |
| 420 | Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. |
| 421 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
| 422 | 15 mm nominal bore |
| 423 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 424 | FIREFIGHTING GROUND FLOOR |
| 425 | Supplying,installing,testingandcommissioningopticaltype smoke detector complete on box as per specification no.FFFAS/ SD |
| 426 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm Dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 427 | SupplyingandinstallingwallmountingswingingHosereel drumfittedwith19mmdia.30meterhighpressure polypropylene(Polyhouse)longfittedwithnecessaryaccessoriescomplete as per specification no. FF-FFA/HV |
| 428 | Supply and Installation CO2 EXTINGUISHER |
| 429 | Supply and Installation ABC EXTINGUSHER |
| 430 | Supply and Installation Hooter |
| 431 | Supply and Installation Manual Call Point |
| 432 | Supply and Installation Fire Alarm Control Panel |
| 433 | Supply and Installation Fire Pump |
| 434 | Supply and Installation Butterfly valve |
| 435 | FIREFIGHTING FIRST FLOOR |
| 436 | Supplying,installing,testingandcommissioningopticaltype smoke detector complete on box as per specification no.FFFAS/ SD |
| 437 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm Dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 438 | SupplyingandinstallingwallmountingswingingHosereel drumfittedwith19mmdia.30meterhighpressure polypropylene(Polyhouse)longfittedwithnecessaryaccessories complete as per specification no. FF-FFA/HV |
| 439 | Supply and Installation CO2 EXTINGUISHER |
| 440 | Supply and Installation ABC EXTINGUSHER |
| 441 | Supply and Installation Hooter |
| 442 | Supply and Installation Manual Call Point |
| 443 | Supply and Installation Fire Alarm Control Panel |
| 444 | Supply and Installation Butterfly valve |
| 445 | GROUND FLOOR- INTERNAL ELECTRIFICATION |
| 446 | Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories |
| 447 | a. Light point Short |
| 448 | b. Light point Medium |
| 449 | c. Light point Long |
| 450 | d. Call bell Point Long |
| 451 | e. Fan point medium |
| 452 | f. Exhaust fan point medium |
| 453 | Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc. |
| 454 | a. Medium point |
| 455 | b. Long point |
| 456 | Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc. |
| 457 | a. Medium point |
| 458 | b. Long point |
| 459 | Wiring for circuit/sub-main with pvc insulated copper cable core in surface casing capping etc. |
| 460 | a. With 1.5 mm2 copper cable s/core |
| 461 | b. With 2.5 mm2 copper cable s/core |
| 462 | c. with 4 mm2 copper cable s/core |
| 463 | d. With 6mm2 copper cable s/core |
| 464 | e. With 10mm2 copper cable s/core |
| 465 | f. With 1mm copper cable s/core for earth continuity |
| 466 | Fixing & Providing, Drilling holes and connection etc |
| 467 | a. MCB 10A |
| 468 | b. MCB 16A |
| 469 | c. MCB 20A |
| 470 | d. Isolator 40 Amp 2 pole |
| 471 | e. Isolator 63 Amp 2 pole |
| 472 | f. MCB Box 10 ways |
| 473 | g. MCB Box 12 ways |
| 474 | h. Main Switch 100A |
| 475 | i. Bus-Bar 100A 4 strips |
| 476 | j. TPN 100A |
| 477 | k. Change over Switch 100A |
| 478 | l. Angle holder |
| 479 | m. Bracket holder |
| 480 | n. LED Double tube light fitting 2x40wx4 with all accessories |
| 481 | o. Exhaust fan with all accessories |
| 482 | p. LED bulb 9w |
| 483 | q. Call Bell Ding Dong |
| 484 | r. Bulk head fitting with all accessories |
| 485 | Providing & fixing, drilling holes and connection etc. |
| 486 | a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal, salt etc.as required. The depth of the pit shall be atleast 3m or as per moisture availability. |
| 487 | b. Copper wire 4sq.mm |
| 488 | c. Lightning arrester |
| 489 | d. Panel Board |
| 490 | e.100 Sq.mm Al. LT. Power Cable |
| 491 | Energy Meter |
| 492 | Armed cablefor Main 4 core X 10 Sqmm for Building |
| 493 | Armed cablefor Main 4 core X 4 Sqmm for Building |
| 494 | Armed cablefor Main 4 core X 35 Sqmm for Building |
| 495 | Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) |
| 496 | Supplying, erecting, testing & commissioning of 5 kVA capacity on line pure sine wave, PWM,IGBT based UPS with 0.8 to unity output pf ,single phase input & 1 phase output complete with all protections as per specification. (With batteries) |
| 497 | FIRST FLOOR- INTERNAL ELECTRIFICATION |
| 498 | Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e providing and fixing anchor made 5A flush type switches and all other accessories |
| 499 | a. Light point Short |
| 500 | b. Light point Medium |
| 501 | c. Light point Long |
| 502 | d. Call bell Point Long |
| 503 | e. Fan point medium |
| 504 | f. Exhaust fan point medium |
| 505 | Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc. |
| 506 | a. Medium point |
| 507 | b. Long point |
| 508 | Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc. |
| 509 | a. Medium point |
| 510 | b. Long point |
| 511 | Wiring for circuit/sub-main with pvc insulated copper cable core in surface casing capping etc. |
| 512 | a. With 1.5 mm2 copper cable s/core |
| 513 | b. With 2.5 mm2 copper cable s/core |
| 514 | c. with 4 mm2 copper cable s/core |
| 515 | d. With 6mm2 copper cable s/core |
| 516 | e. With 10mm2 copper cable s/core |
| 517 | f. With 1mm copper cable s/core for earth continuity |
| 518 | Fixing & Providing, Drilling holes and connection etc |
| 519 | a. MCB 10A |
| 520 | b. MCB 16A |
| 521 | c. MCB 20A |
| 522 | d. Isolator 40 Amp 2 pole |
| 523 | e. Isolator 63 Amp 2 pole |
| 524 | f. MCB Box 10 ways |
| 525 | g. MCB Box 12 ways |
| 526 | h. Angle holder |
| 527 | i. Bracket holder |
| 528 | j. LED Double tube light fitting 2x40wx4 with all accessories |
| 529 | k. Exhaust fan with all accessories |
| 530 | l. LED bulb 9w |
| 531 | m. Call Bell Ding Dong |
| 532 | n. Bulk head fitting with all accessories |
| 533 | Providing & fixing, drilling holes and connection etc. |
| 534 | a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal,salt etc.as required. The depth of the pit shall be atleast 3m or as per moisture availability. |
| 535 | b. Copper wire 4sq.mm |
| 536 | c. Lightning arrester |
| 537 | d. Panel Board |
| 538 | Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) |
| 539 | EXTERNAL ELECTRIFICATION |
| 540 | Fixing & Providing, Drilling holes and connection etc |
| 541 | a. MCB 20A |
| 542 | b. Isolator 63 Amp 2 pole |
| 543 | c. Main Switch 100A |
| 544 | d. Bus-Bar 100A 4 strips |
| 545 | e. TPN 100A |
| 546 | f. Change over Switch 100A |
| 547 | g. 60 watt LED for street Light |
| 548 | h. Pole |
| 549 | i. Pole Arm |
| 550 | a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal, salt etc.as required. The depth of the pit shall be at least 3m or as per moisture availability. |
| 551 | b. Copper wire 4sq.mm |
| 552 | c. Lightning arrester |
| 553 | d. Panel Board |
| 554 | e.100 Sq.mm Al. LT. Power Cable |
| 555 | Supply and Installation Energy Meter |
| 556 | Armed cablefor Main 4 core X 10 Sqmm for Street light |
| 557 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 30 kVA output continuous rating, 3 phase, 415 V, 50 Hz, 0.8 p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2/G3 and maximum fuel consumption 5.9 ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads, with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc., as per specification |
| 558 | BOYS HOSTEL GROUND FLOOR CIVIL |
| 559 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 560 | All kind of Soil |
| 561 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 562 | Ordinary Rock |
| 563 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) |
| 564 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 565 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 566 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 567 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with common burnt clay non-modular bricks: |
| 568 | 1:4 (1 cement: 4 coarse sand) |
| 569 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 570 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 571 | Coursed rubble masonry (first or second sort) with hard stone In super structure above plinth level and upto floor five level: |
| 572 | Masonry work (first sort), in Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 573 | Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately) |
| 574 | All works upto Plinth level |
| 575 | All works above Plinth level upto floor V level |
| 576 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement 2 coarse sand 4 graded stone aggregate 12.5mm nominal size). |
| 577 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 578 | Foundations, footings, bases of Columns |
| 579 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 580 | Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers |
| 581 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 582 | Columns, Pillars, Piers, Abutments, Posts & Struts |
| 583 | Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses. |
| 584 | 0.50 mm thick |
| 585 | Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 586 | Hot finished welded type tubes |
| 587 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 588 | Hot Rolled deformed bars |
| 589 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 590 | With F. P. S. (non-modular) bricks |
| 591 | Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 592 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 593 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 594 | Second class teak wood |
| 595 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked |
| 596 | 12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked |
| 597 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid seperately) |
| 598 | Second class Teak wood |
| 599 | 30mm thick shutters |
| 600 | Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge. |
| 601 | Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 602 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 603 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 604 | 100x75x4 mm |
| 605 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: |
| 606 | 250x16 mm |
| 607 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 608 | 200 * 10mm |
| 609 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 610 | 125 mm |
| 611 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 612 | Twin rubber stopper |
| 613 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 614 | Fixed to opening/ wooden frames with rawl plugs screws etc. |
| 615 | Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse 25 mm thick |
| 616 | Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades. |
| 617 | 8mm thick (mirror polished and machine cut edge) |
| 618 | Granite stone of any colour and shade |
| 619 | Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with: |
| 620 | Udaipur green marble |
| 621 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 622 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete |
| 623 | Size of Tile 600x600 mm |
| 624 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) |
| 625 | Size of Tile 600x600 mm |
| 626 | 12 mm cement plaster of mix: |
| 627 | 1:6 (1 cement :6 Coarse sand) |
| 628 | 20 mm cement plaster of mix: |
| 629 | 1:6 (1 cement :6 Coarse sand) |
| 630 | 6 mm cement plaster of mix: |
| 631 | (1 cement: 3 fine sand) |
| 632 | Applying priming coat |
| 633 | With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood) |
| 634 | Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant. |
| 635 | Painting with synthetic enamel paint of approval brand and manufacture to give an even shade |
| 636 | Two or more coats on new work |
| 637 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 638 | Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content. |
| 639 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 640 | Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour. |
| 641 | Two Coats |
| 642 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 643 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately) |
| 644 | For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately) |
| 645 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15): |
| 646 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item) |
| 647 | With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 648 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) |
| 649 | BOYS HOSTEL FIRST FLOOR CIVIL |
| 650 | Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately) |
| 651 | All works above Plinth level upto floor V level |
| 652 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 653 | Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers |
| 654 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 655 | Columns, Pillars, Piers, Abutments, Posts & Struts |
| 656 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 657 | Hot Rolled deformed bars |
| 658 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 659 | With F. P. S. (non-modular) bricks |
| 660 | Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 661 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 662 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 663 | Second class teak wood |
| 664 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked |
| 665 | 12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked |
| 666 | Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge. |
| 667 | Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 668 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 669 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 670 | 100x75x4 mm |
| 671 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: |
| 672 | 250x16 mm |
| 673 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 674 | 200 * 10mm |
| 675 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 676 | 125 mm |
| 677 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 678 | Twin rubber stopper |
| 679 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 680 | Fixed to opening/ wooden frames with rawl plugs screws etc. |
| 681 | Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades. |
| 682 | 8mm thick (mirror polished and machine cut edge) |
| 683 | Granite stone of any colour and shade |
| 684 | Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with: |
| 685 | Udaipur green marble |
| 686 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 687 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete |
| 688 | Size of Tile 600x600 mm |
| 689 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) |
| 690 | Size of Tile 600x600 mm |
| 691 | Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses. |
| 692 | 0.50 mm thick |
| 693 | Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 694 | Hot finished welded type tubes |
| 695 | 12 mm cement plaster of mix: |
| 696 | 1:6 (1 cement :6 Coarse sand) |
| 697 | 20 mm cement plaster of mix: |
| 698 | 1:6 (1 cement :6 Coarse sand) |
| 699 | Applying priming coat |
| 700 | With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood) |
| 701 | Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant. |
| 702 | Painting with synthetic enamel paint of approval brand and manufacture to give an even shade |
| 703 | Two or more coats on new work |
| 704 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 705 | Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content. |
| 706 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 707 | Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour. |
| 708 | Two Coats |
| 709 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately) |
| 710 | For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately) |
| 711 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15): |
| 712 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item) |
| 713 | With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 714 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) |
| 715 | BOYS HOSTEL SEPTIC TANK |
| 716 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 717 | All kind of Soil |
| 718 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 719 | Ordinary Rock |
| 720 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level |
| 721 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 722 | Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement. |
| 723 | 1:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size) |
| 724 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 725 | Hot Rolled deformed bars |
| 726 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 727 | With F. P. S. (non-modular) bricks |
| 728 | 12 mm cement plaster finished with floating coat of neat cement of mix |
| 729 | 1:4 (1 cement :4 Fine sand) |
| 730 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) |
| 731 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: |
| 732 | Inside dimensions 600x850 mm and 45 cm deep for single pipe line. |
| 733 | With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 |
| 734 | BOYS HOSTEL GROUND FLOOR PLUMBING |
| 735 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 |
| 736 | 15 mm nominal bore |
| 737 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require: |
| 738 | White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 739 | Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid |
| 740 | W.C. pan with ISI marked black solid plastic seat and lid |
| 741 | Providing and fixing white vitreous China flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: |
| 742 | Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 743 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 744 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 745 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. |
| 746 | Rectangular shape 453x357mm dia. |
| 747 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge |
| 748 | Concealed work, including cutting chases and making good the walls etc. |
| 749 | 20 mm nominal outer dia Pipes |
| 750 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge |
| 751 | External work |
| 752 | 40 mm nominal outer dia Pipes |
| 753 | 50 mm nominal outer dia Pipes |
| 754 | Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete |
| 755 | Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. |
| 756 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With common burnt clay F.P.S( non-modular ) bricks of class designation 7.5 |
| 757 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore |
| 758 | Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
| 759 | 100x100 mm size P type |
| 760 | With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 |
| 761 | BOYS HOSTEL FIRST FLOOR PLUMBING |
| 762 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 |
| 763 | 15 mm nominal bore |
| 764 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require: |
| 765 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 766 | Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid |
| 767 | W.C. pan with ISI marked black solid plastic seat and lid |
| 768 | Providing and fixing white vitreous China flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.1. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: |
| 769 | Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 770 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. |
| 771 | Rectangular shape 453x357mm dia. |
| 772 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge |
| 773 | Concealed work, including cutting chases and making good the walls etc. |
| 774 | 20 mm nominal outer dia Pipes |
| 775 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge |
| 776 | External work |
| 777 | 40 mm nominal outer dia Pipes |
| 778 | 50 mm nominal outer dia Pipes |
| 779 | Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete |
| 780 | Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. |
| 781 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore |
| 782 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 783 | BOYS HOSTEL GROUND FLOOR- INTERNAL ELECTRIFICATION |
| 784 | Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories |
| 785 | a. Light point Short |
| 786 | b. Light point Medium |
| 787 | c. Light point Long |
| 788 | d. Call bell Point Long |
| 789 | e. Fan point medium |
| 790 | f. Exhaust fan point medium |
| 791 | Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc. |
| 792 | a. Medium point |
| 793 | b. Long point |
| 794 | Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc. |
| 795 | a. Medium point |
| 796 | b. Long point |
| 797 | Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc. |
| 798 | a. With 1.5 mm2 copper cable s/core |
| 799 | b. With 2.5 mm2 copper cable s/core |
| 800 | c. with 4 mm2 copper cable s/core |
| 801 | d. With 6mm2 copper cable s/core |
| 802 | e. With 10mm2 copper cable s/core |
| 803 | f. With 1mm copper cable s/core for earth continuity |
| 804 | Fixing & Providing, Drilling holes and connection etc |
| 805 | a. MCB 10A |
| 806 | b. MCB 16A |
| 807 | c. MCB 20A |
| 808 | d. Isolator 40 Amp 2 pole |
| 809 | e. Isolator 63 Amp 2 pole |
| 810 | f. MCB Box 10 ways |
| 811 | g. MCB Box 12 ways |
| 812 | h. Main Switch 100A |
| 813 | i. Bus-Bar 100A 4 strips |
| 814 | j. TPN 100A |
| 815 | k. Change over Switch 100A |
| 816 | l. Angle holder |
| 817 | m. Bracket holder |
| 818 | n. LED Double tube light fitting 2x40wx4 with all accessories |
| 819 | o. Exhaust fan with all accessories |
| 820 | p. LED bulb 9w |
| 821 | q. Call Bell Ding Dong |
| 822 | r. Bulk head fitting with all accessories |
| 823 | Providing & fixing, drilling holes and connection etc. |
| 824 | a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal, salt etc.as required. The depth of the pit shall be atleast 3m or as per moisture availability. |
| 825 | b. Copper wire 4sq.mm |
| 826 | c. Lightning arrester |
| 827 | d. Panel Board |
| 828 | e.100 Sq.mm Al. LT. Power Cable |
| 829 | Supplying and installing Energy Meter |
| 830 | Armed cablefor Main 4 core X 10 Sqmm for Building |
| 831 | Armed cablefor Main 4 core X 4 Sqmm for Building |
| 832 | Armed cablefor Main 4 core X 35 Sqmm for Building |
| 833 | Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) |
| 834 | BOYS HOSTEL FIRST FLOOR- INTERNAL ELECTRIFICATION |
| 835 | Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories |
| 836 | a. Light point Short |
| 837 | b. Light point Medium |
| 838 | c. Light point Long |
| 839 | d. Call bell Point Long |
| 840 | e. Fan point medium |
| 841 | f. Exhaust fan point medium |
| 842 | Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc. |
| 843 | a. Medium point |
| 844 | b. Long point |
| 845 | Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc. |
| 846 | a. Medium point |
| 847 | b. Long point |
| 848 | Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc. |
| 849 | a. With 1.5 mm2 copper cable s/core |
| 850 | b. With 2.5 mm2 copper cable s/core |
| 851 | c. with 4 mm2 copper cable s/core |
| 852 | d. With 6mm2 copper cable s/core |
| 853 | e. With 10mm2 copper cable s/core |
| 854 | f. With 1mm copper cable s/core for earth continuity |
| 855 | Fixing & Providing, Drilling holes and connection etc |
| 856 | a. MCB 10A |
| 857 | b. MCB 16A |
| 858 | c. MCB 20A |
| 859 | d. Isolator 40 Amp 2 pole |
| 860 | e. Isolator 63 Amp 2 pole |
| 861 | f. MCB Box 10 ways |
| 862 | g. MCB Box 12 ways |
| 863 | h. Main Switch 100A |
| 864 | i. Angle holder |
| 865 | j. Bracket holder |
| 866 | k. LED Double tube light fitting 2x40wx4 with all accessories |
| 867 | l. Exhaust fan with all accessories |
| 868 | m. LED bulb 9w |
| 869 | n. Call Bell Ding Dong |
| 870 | o. Bulk head fitting with all accessories |
| 871 | GIRLS HOSTEL GROUND FLOOR CIVIL |
| 872 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 873 | All kind of Soil |
| 874 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 875 | Ordinary Rock |
| 876 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) |
| 877 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 878 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 879 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 880 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar, including filling the joints with same mortar, with common burnt clay non-modular bricks: |
| 881 | 1:4 (1 cement: 4 coarse sand) |
| 882 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 883 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 884 | Coursed rubble masonry (first or second sort) with hard stone In super structure above plinth level and upto floor five level: |
| 885 | Masonry work (first sort), in Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 886 | Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately) |
| 887 | All works upto Plinth level |
| 888 | All works above Plinth level upto floor V level |
| 889 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement 2 coarse sand 4 graded stone aggregate 12.5mm nominal size). |
| 890 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 891 | Foundations, footings, bases of Columns |
| 892 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 893 | Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers |
| 894 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 895 | Columns, Pillars, Piers, Abutments, Posts & Struts |
| 896 | Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses. |
| 897 | 0.50 mm thick |
| 898 | Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 899 | Hot finished welded type tubes |
| 900 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 901 | Hot Rolled deformed bars |
| 902 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 903 | With F. P. S. (non-modular) bricks |
| 904 | Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 905 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 906 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 907 | Second class teak wood |
| 908 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked |
| 909 | 12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked |
| 910 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-Charge. (Note: Butt hinges and necessary screws shall be paid seperately) |
| 911 | Second class Teak wood |
| 912 | 30mm thick shutters |
| 913 | Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge. |
| 914 | Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 915 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 916 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 917 | 100x75x4 mm |
| 918 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: |
| 919 | 250x16 mm |
| 920 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 921 | 200 * 10mm |
| 922 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 923 | 125 mm |
| 924 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 925 | Twin rubber stopper |
| 926 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 927 | Fixed to opening/ wooden frames with rawl plugs screws etc. |
| 928 | Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse 25 mm thick |
| 929 | Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades. |
| 930 | 8mm thick (mirror polished and machine cut edge) |
| 931 | Granite stone of any colour and shade |
| 932 | Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with: |
| 933 | Udaipur green marble |
| 934 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 935 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete |
| 936 | Size of Tile 600x600 mm |
| 937 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) |
| 938 | Size of Tile 600x600 mm |
| 939 | 12 mm cement plaster of mix: |
| 940 | 1:6 (1 cement :6 Coarse sand) |
| 941 | 20 mm cement plaster of mix: |
| 942 | 1:6 (1 cement :6 Coarse sand) |
| 943 | 6 mm cement plaster of mix: |
| 944 | (1 cement: 3 fine sand) |
| 945 | Applying priming coat |
| 946 | With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood) |
| 947 | Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant. |
| 948 | Painting with synthetic enamel paint of approval brand and manufacture to give an even shade |
| 949 | Two or more coats on new work |
| 950 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 951 | Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content. |
| 952 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 953 | Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour. |
| 954 | Two Coats |
| 955 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 956 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately) |
| 957 | For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately) |
| 958 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15): |
| 959 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item) |
| 960 | With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 961 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) |
| 962 | GIRLS HOSTEL FIRST FLOOR CIVIL |
| 963 | Providing and laying in position ready mixed M25 grade concrete for RCC work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixture, manufactured as per Mix Design of specified Grade for RCC work, including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per 15-9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. (NOTE: Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately) |
| 964 | All works above Plinth level upto floor V level |
| 965 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 966 | Lintels, Beams, Plinth beams, Girders, Bressumers & Cantilevers |
| 967 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 968 | Columns, Pillars, Piers, Abutments, Posts & Struts |
| 969 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 970 | Hot Rolled deformed bars |
| 971 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 972 | With F. P. S. (non-modular) bricks |
| 973 | Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 974 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 975 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 976 | Second class teak wood |
| 977 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part 8) fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer-incharge and panelling with panels of: (Note: screws shall be paid seperately) Butt hinges and necessary12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked |
| 978 | 12 mm thick one side prelaminated particle board (decorative lamination on one side and other sides balancing lamination) grade - 1 medium density, flat pressed, three layer particle board FPT I or graded wood particle board FPT-1 IS: 3087 - bonded with BWP type synthetic resin adhesive as per IS: 848 and prelamination conforming to IS: 12823 Grade 1, Type II marked |
| 979 | Providing and fixing factory made P.V.C. door frame of size 50 * 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15 * 15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19 * 19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided throughout the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer-in-Charge. |
| 980 | Providing and fixing ISI marked flush door shutters conforming to S: 2202 (part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 981 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 982 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 983 | 100x75x4 mm |
| 984 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: |
| 985 | 250x16 mm |
| 986 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 987 | 200 * 10mm |
| 988 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: |
| 989 | 125 mm |
| 990 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 991 | Twin rubber stopper |
| 992 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 993 | Fixed to opening/ wooden frames with rawl plugs screws etc. |
| 994 | Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shades. |
| 995 | 8mm thick (mirror polished and machine cut edge) |
| 996 | Granite stone of any colour and shade |
| 997 | Marble stone flooring with 18mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with: |
| 998 | Udaipur green marble |
| 999 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 1000 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 Cement: 3 Coarse sand), jointing with Grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete |
| 1001 | Size of Tile 600x600 mm |
| 1002 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) |
| 1003 | Size of Tile 600x600 mm |
| 1004 | Providing Zinc Aluminium Alloy Galvanized coloured trapezoidal profile steel (width 1120 mm) (DYNA, DURASHINE, BLUESCOPE etc) complete (upto a pitch of 60 degrees) excluding the cost of purlins, rafters and trusses. |
| 1005 | 0.50 mm thick |
| 1006 | Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 1007 | Hot finished welded type tubes |
| 1008 | 12 mm cement plaster of mix: |
| 1009 | 1:6 (1 cement :6 Coarse sand) |
| 1010 | 20 mm cement plaster of mix: |
| 1011 | 1:6 (1 cement :6 Coarse sand) |
| 1012 | Applying priming coat |
| 1013 | With ready mix pink or gray of approved brand manufacture on wood work ( hard and soft wood) |
| 1014 | Providing and applying two coat of fire retardant paint on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendation of manufacturer to make the surface fire retardant. |
| 1015 | Painting with synthetic enamel paint of approval brand and manufacture to give an even shade |
| 1016 | Two or more coats on new work |
| 1017 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 1018 | Applying priming coat with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content. |
| 1019 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 1020 | Wall painting with Acrylic emulsion paint, having VOC (Volatile organic compound) content lesss than 50 gm/liter, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour. |
| 1021 | Two Coats |
| 1022 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia in size, including necessary filling up the gaps at junctions 1.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawing and the direction of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for seperately) |
| 1023 | For shutters of doors, windows, ventilators including providing and fixing hinges/pivots and making provision for fixing of fitting wherever required including the cost of EPDM rubber/ neoprene gasket required (Fitting shall be paid for seperately) |
| 1024 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15): |
| 1025 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item) |
| 1026 | With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 1027 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) |
| 1028 | GIRLS HOSTEL SEPTIC TANK |
| 1029 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 1030 | All kind of Soil |
| 1031 | Earth work in excavation by mechanical means (Hydraulic excavator/Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 1032 | Ordinary Rock |
| 1033 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work upto Plinth Level |
| 1034 | 1:3:6 (1 Cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size) |
| 1035 | Reinforced cement concrete work in walls (any thickness), Including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement. |
| 1036 | 1:1.5:3 (1 Cement: 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size) |
| 1037 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 1038 | Hot Rolled deformed bars |
| 1039 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): |
| 1040 | With F. P. S. (non-modular) bricks |
| 1041 | 12 mm cement plaster finished with floating coat of neat cement of mix |
| 1042 | 1:4 (1 cement :4 Fine sand) |
| 1043 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) 3rd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) |
| 1044 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: |
| 1045 | Inside dimensions 600x850 mm and 45 cm deep for single pipe line. |
| 1046 | With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 |
| 1047 | GIRLS HOSTEL GROUND FLOOR PLUMBING |
| 1048 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require: |
| 1049 | White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 1050 | Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid |
| 1051 | W.C. pan with ISI marked black solid plastic seat and lid |
| 1052 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 1053 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 1054 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. |
| 1055 | Rectangular shape 453x357mm dia. |
| 1056 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge |
| 1057 | Concealed work, including cutting chases and making good the walls etc. |
| 1058 | 20 mm nominal outer dia Pipes |
| 1059 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge |
| 1060 | External work |
| 1061 | 40 mm nominal outer dia Pipes |
| 1062 | 50 mm nominal outer dia Pipes |
| 1063 | Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete |
| 1064 | Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. |
| 1065 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. |
| 1066 | With common burnt clay F.P.S( non-modular ) bricks of class designation 7.5 |
| 1067 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore |
| 1068 | Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
| 1069 | 100x100 mm size P type |
| 1070 | With common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 |
| 1071 | GIRLS HOSTEL FIRST FLOOR PLUMBING |
| 1072 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require: |
| 1073 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 1074 | Providing and fixing white vitreous China pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked black solid plastic seat and lid |
| 1075 | W.C. pan with ISI marked black solid plastic seat and lid |
| 1076 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. |
| 1077 | Rectangular shape 453x357mm dia. |
| 1078 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge |
| 1079 | Concealed work, including cutting chases and making good the walls etc. |
| 1080 | 20 mm nominal outer dia Pipes |
| 1081 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge |
| 1082 | External work |
| 1083 | 40 mm nominal outer dia Pipes |
| 1084 | 50 mm nominal outer dia Pipes |
| 1085 | Providing and fixing 75mmdia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete |
| 1086 | Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. |
| 1087 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore |
| 1088 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 1089 | GIRLS HOSTEL GROUND FLOOR- INTERNAL ELECTRIFICATION |
| 1090 | Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories |
| 1091 | a. Light point Short |
| 1092 | b. Light point Medium |
| 1093 | c. Light point Long |
| 1094 | d. Call bell Point Long |
| 1095 | e. Fan point medium |
| 1096 | f. Exhaust fan point medium |
| 1097 | Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc. |
| 1098 | a. Medium point |
| 1099 | b. Long point |
| 1100 | Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc. |
| 1101 | a. Medium point |
| 1102 | b. Long point |
| 1103 | Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc. |
| 1104 | a. With 1.5 mm2 copper cable s/core |
| 1105 | b. With 2.5 mm2 copper cable s/core |
| 1106 | c. with 4 mm2 copper cable s/core |
| 1107 | d. With 6mm2 copper cable s/core |
| 1108 | e. With 10mm2 copper cable s/core |
| 1109 | f. With 1mm copper cable s/core for earth continuity |
| 1110 | Fixing & Providing, Drilling holes and connection etc |
| 1111 | a. MCB 10A |
| 1112 | b. MCB 16A |
| 1113 | c. MCB 20A |
| 1114 | d. Isolator 40 Amp 2 pole |
| 1115 | e. Isolator 63 Amp 2 pole |
| 1116 | f. MCB Box 10 ways |
| 1117 | g. MCB Box 12 ways |
| 1118 | h. Main Switch 100A |
| 1119 | i. Bus-Bar 100A 4 strips |
| 1120 | j. TPN 100A |
| 1121 | k. Change over Switch 100A |
| 1122 | l. Angle holder |
| 1123 | m. Bracket holder |
| 1124 | n. LED Double tube light fitting 2x40wx4 with all accessories |
| 1125 | o. Exhaust fan with all accessories |
| 1126 | p. LED bulb 9w |
| 1127 | q. Call Bell Ding Dong |
| 1128 | r. Bulk head fitting with all accessories |
| 1129 | Providing & fixing, drilling holes and connection etc. |
| 1130 | a. Earthing complete set with copper plate 2x2x4 mm thick including charcoal, salt etc.as required. The depth of the pit shall be atleast 3m or as per moisture availability. |
| 1131 | b. Copper wire 4sq.mm |
| 1132 | c. Lightning arrester |
| 1133 | d. Panel Board |
| 1134 | e.100 Sq.mm Al. LT. Power Cable |
| 1135 | Supplying and installing Energy Meter |
| 1136 | Armed cablefor Main 4 core X 10 Sqmm for Building |
| 1137 | Armed cablefor Main 4 core X 4 Sqmm for Building |
| 1138 | Armed cablefor Main 4 core X 35 Sqmm for Building |
| 1139 | Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) |
| 1140 | GIRLS HOSTEL FIRST FLOOR- INTERNAL ELECTRIFICATION |
| 1141 | Wiring with 1.5 mm2 single core copper cable in surface casing capping i.e. providing and fixing anchor made 5A flush type switches and all other accessories |
| 1142 | a. Light point Short |
| 1143 | b. Light point Medium |
| 1144 | c. Light point Long |
| 1145 | d. Call bell Point Long |
| 1146 | e. Fan point medium |
| 1147 | f. Exhaust fan point medium |
| 1148 | Wiring with 3 pin5A plug with single core copper cable 2.5 mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 5A socket outlet and 5aA flush type switches and earthing the third pin etc. |
| 1149 | a. Medium point |
| 1150 | b. Long point |
| 1151 | Wiring with 3 pin 15A plug with single core copper cable 4mm2 in surface casing capping i.e. providing and fixing anchor made 3 pin 15A socket outlet and 15A flush type switches and earthing the third pin etc. |
| 1152 | a. Medium point |
| 1153 | b. Long point |
| 1154 | Wiring for circuit/sub-main with PVC insulated copper cable core in surface casing capping etc. |
| 1155 | a. With 1.5 mm2 copper cable s/core |
| 1156 | b. With 2.5 mm2 copper cable s/core |
| 1157 | c. with 4 mm2 copper cable s/core |
| 1158 | d. With 6mm2 copper cable s/core |
| 1159 | e. With 10mm2 copper cable s/core |
| 1160 | f. With 1mm copper cable s/core for earth continuity |
| 1161 | Fixing & Providing, Drilling holes and connection etc |
| 1162 | a. MCB 10A |
| 1163 | b. MCB 16A |
| 1164 | c. MCB 20A |
| 1165 | d. Isolator 40 Amp 2 pole |
| 1166 | e. Isolator 63 Amp 2 pole |
| 1167 | f. MCB Box 10 ways |
| 1168 | g. MCB Box 12 ways |
| 1169 | h. Main Switch 100A |
| 1170 | i. Angle holder |
| 1171 | j. Bracket holder |
| 1172 | k. LED Double tube light fitting 2x40wx4 with all accessories |
| 1173 | l. Exhaust fan with all accessories |
| 1174 | m. LED bulb 9w |
| 1175 | n. Call Bell Ding Dong |
| 1176 | o. Bulk head fitting with all accessories |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy