}

Tender For Provision Of Certain Deficient Omqs At Gagan Vihar Camp At Bangalore, marathahalli-Karnataka

Statutory Bodies & Commissions/Committees has published Tender For Provision Of Certain Deficient Omqs At Gagan Vihar Camp At Bangalore. Submission Date for this Tender is 25-10-2024. Building Work Tenders in marathahalli Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

45573980
Tender For Provision Of Certain Deficient Omqs At Gagan Vihar Camp At Bangalore
Open Tender
Indian
Karnataka
Marathahalli
25-10-2024

Tender Documents

Tender Details

Tender For Provision Of certain Deficient Omqs At Gagan Vihar Camp At Bangalore; 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XIV are prepriced by MES under Ser No. 1 to 14. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “BUILDING OR WORKS” as listed in Schedule ‘A’Part–I 4 Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’Part–II 5 Lumpsum price worked out by the contractor for “INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’Part–III 6 Lumpsum price worked out by the contractor for “ GREASE TRAPS ” as listed in Schedule ‘A’ Part – IV. 7 Lumpsum price worked out by the contractor for “ROAD/PATH/CULVERTas listed in Schedule ‘A’ Part V . 8 Lumpsum price worked out by the contractor for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part VI . 9 Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part – VII. 10 Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part – VIII. 11 Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part – IX. 12 Lumpsum price worked out by the contractor for “COOLING APPLIANCES” as listed in Schedule ‘A’ Part – X. 13 Lumpsum price worked out by the contractor for LIFT” as listed in Schedule ‘A’ Part – XI. 14 Lumpsum price worked out by the contractor for LIGHTENING PROTECTION as listed in Schedule ‘A’ Part XII. 15 Lumpsum price worked out by the contractor for “DGSETS ” as listed in Schedule ‘A’ Part – XIII. 16 Lumpsum price worked out by the contractor for HOT WATER SUPPLY” as listed in Schedule ‘A’ Part – XIV 17 Lumpsum price worked out by the contractor for “FIRE ALARM DETECTION SYSTEM” as listed in Schedule ‘A’ Part – XV 18 Sch A Part - XVI :BUILDINGS OR WORKSDesign and Construction of Multistoried bldg (G+5)for SINGLE LIVING ACCOMMODATION, framed construction with permanent specifications in RCC M-25 (RMC) with PCC Solid block masonry panel walls,WPT, Grass paver blocks, earthquake resistance as per latest IS etc complete all as specified and as shown on drawings. Note: The quoted rate against is deemed to include for the provisions contained in Sch A Notes. Refer Sch A Notes complete before quoting these items. 19 Design and Construction of pump house (10met X 4met) with permanent (S/S) specification, RCC M-25 (RMC) Design Mix, framed construction water proofing Treatmentetc all as specified and as shown on drawings . 20 Design and Construction of building for LPG store (5met X 4met) with permanent (S/S) specification, RCC M-25 (RMC) Design Mix, framed construction water proofing Treatmentetc all as specified and as shown on drawings. 21 Sch A Part - XVII : Fittings / Fixtures & Misc items. INTERNAL ELECTRIC SUPPLY Supply and fixReading in bed side light 3/5 watt white with this collection of adjustable LED bedside lights ,220 Volts,Total 150 Lumens,PF > 0.95, CRI > 80 colour temperature 2700 to 6500K, high voltage protecion, easy instalaltion clips for user-friendely installation,AC decorative box type with driver, holder including retrofitLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 22 Supply and fix MCCB DB VTPN 4 way Vertical double door 415 V AC 50Hz with with MCCB as incomer TP,DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete. specified and as directed. 23 Supply and fixing TPN distribution boards,Vertical type, protection class IP-43, Double door,4 Way, suitable for mounting MCCBas incomer and MCB SP,TP as outgoing with min 400 Amps rating bus bar ,concealed in wall all as specified and directed by engineer in charge . 24 Material and labour for 3 layer( iner antimicrobail, outer UV stablised) ISI marked,IS-15801, PP-R Pipes SDR 7.4 (PN-16) & PP-R plain fittings in trench/walls/ceilings or laying in floors complete of size outer size 110 mm includingfittingsall as specified and directed. 25 Sch A Part - XVII:- Fittings / Fixtures & Misc items. EXTERNAN WATER SUPPLYMaterial and labour for 3 layer( iner antimicrobail, outer UV stablised) ISI marked,IS-15801, PP-R Pipes SDR 7.4 (PN-16) & PP-R plain fittings in trench/walls/ceilings or laying in floors complete of size outer size 110 mm includingfittingsall as specified and directed. 26 Material and labour for 3 layer( iner antimicrobail, outer UV stablised) ISI marked,IS-15801, PP-R Pipes SDR 7.4 (PN-10) & PP-R plain fittings in trench/walls/ceilings or laying in floors complete of size outer size 50 mm includingfittingsall as specified and directed. 27 Material and labour for 3 layer( iner antimicrobail, outer UV stablised) ISI marked,IS-15801, PP-R Pipes SDR 7.4 (PN-16) & PP-R plain fittings in trench/walls/ceilings or laying in floors complete of size outer size25 mm includingfittingsall as specified and directed. 28 Material and labour for PP-R gate valve, brass insert and installed complete for size 110 mm dia pipe all as specified and directed. 29 Material and labour for PP-R gate valve, brass insert and installed complete for size 50 mm dia pipe all as specified and directed. 30 Material and labour for PP-R gate valve, brass insert and installed complete for size 25 mm dia pipe all as specified and directed. 31 Material and labour forReflexvalve,flanged type and installed complete for size 100 mm dia pipe all as specified and directed. 32 Material and labour forfootvalve,flanged type and installed complete for size 100 mm dia pipe all as specified and directed. 33 Material and labour for Construction of valve chamber having inner dimension 900 x 900 x 900 mm suitable for upto 90 mmvalve with PCC 1: 4: 8 type D2 for foundation, brick work wall in cement mortar (1:4), PCC 1: 2: 4 type B1 for copping rendering plaster in CM 1:4, 15mm thick including provision of MS Sheet cover made out 3 mm thick MS sheet with 40 x 40 x 6 mm,iron frame and two coat of synthetic enamel paint over a coat of red oxide primer and locking arrangements including necessary excavation earth work complete all as specified. 34 Supply install testing and commissioning of three phase5HP centrifugal pump sethaving maximum delivery head 51 mtr withall as per manufacturer specification fixed on common base plate with suitable foundation bolts and nuts grouted in and including PCC platform 1:2:4 type B2 using 40mm graded stone aggregate medium gradeand jointed with gaskets and nuts bolts etc inclusive of startercomplete all as specified and directed 35 EXTERNAL ELECTRIC SUPPLYMaterial and labour for Alkathene pipe of20 mm dia 2 mm thick fixed over ACSR conductors / jumpers etc all as directed. 36 Supply ,installation, testing & commissioning of step down transformer 160 KVA ,11/0.433 KV ,3 phase ,50 Hz ,ONAN cooled oil immersed copper wound outdoor type step down transformer complete with first filling of new transformer oil with specified Breakdown voltage as per IS ,ISI marked filtered & dehydrated transformer oil and other standard fittings /accessories and 7 position off circuit tap changer with - 7.5 to +7.5 in steps of 2.5, vector group dyn -11, EEL-2 of IS : 1180 -2014.Total losses570W @50%Load,1700W @ 100%Load, HV cable box and LV cable box is included with all fittings/accessories ” complete all as specified and as directed . 37 Design , fabricating supply, installation ,testing & commissioning of LT outdoor panel board 3 phase 4 wire system outdoor double door front and back opening type slopped canopy (hood ) on top extended 100 mm al around separate compartment for each control gear cable alley , provn of knock out type plates for various sizes of cable up to 120 sqmm 3.5 core in and out incoming and outgoing feeders duly marked, CPRI type tested fabricated out of 3.0mm thick CRCA sheetpainted with epoxy powder coated mat finish pre wired with PVC insulated multi stranded copper conductor for controls and monitors , PV sleeved mounted on angle ironframe of 50x50x6 mm thick embded in pcc 1:3:6, 45 cm below ground level & 15 cm above ground levelconsisting of following and complete all as directed by Engineer in charge .(a) Aluminium bus bar of 600 Amps capacity duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of class “F” class insulators.(b) MCCB TPN 415 Volts 50 Hz 400 Amps 36 KA rupturing capacitymicroprocessor releases (Incoming)(c) MCCB TPN 425 Volts 50 Hz 250 Amps 36 KA rupturing capacity with thermal and magnetric releases (Outgoing ) 1 No SNCOs Mess(d) MCCB TPN 415 Volts 50 Hz 100 Amps KA rupturing Capacity Outgoing -02 Nos(Spare -01)(e) Multi functional Meter (LED display ) to read KWH ,Amps,Volts and frequency etc of each phase (3 PH,4W IPM 240 V(L-N)5A Class 1 FM(f) Indicator LED type for RYB set 3 -01 set 38 Supply and installation of APFC PANEL (60KVAR) APFC PANEL (60KVAR)60 KVAR Automatic power factor correction panel in 6 steps (10 KVAR x 6 ) consisting of follwing :-(i)160Amps 433V 3P 36KA Manual Fixed Type Moulded Case Circuit Breaker (MCCB) with Thermal mangetic based release for over current and magnetic short circuit as incomer to APFC Panel - 01 No(ii)APFC RVC Relay for 6 steps - 01 No(iii)10 KVAR metallized polypropylene capacitor bank - 06 Nos(iv) Capacitor duty contactor for switching on & switching off 10 KVAR bank- 06 Nos(v) 32Amps 433V 3P 10KA Miniature Circuit Breaker for 10KVAR capacitor protection- 06 Nos(vi) FAN for heat discipiation & cooling of capacitor bank - 01 NoThe switching devicefor individual capacitors in stages shall beMCB TP 5 to 32Amps C seriesof 10 KArepturing one Each number for individual capacitor stage, contactor MNX 18 APFC Relay with LCD display, 3 Nos of load feed back CTs ( one per phase) copper bus bar 100 Amps capacity for RYB &N set of 4 duly sleeved with heat shrinkable PVC sleeves using colour code, Indication lamp for RYB, LED indication at incomer & capacitor ON/OFF push buttons and ON/OFFstatusindicator etc on APFC Relay with copper cable four core including necessary accessories for connecting to panel both endsspecified and directed. 39 Design , fabricating supply, installation ,testing & commissioning ofDG cubicle panel board3 phase 4 wire system outdoor double door front and back opening type slopped canopy (hood ) on top extended 100 mm al around separate compartment for each control gear cable alley , provn of knock out type plates for various sizes of cable up to 95sqmm 3.5 core in and out incomming and outgoing feeders duly marked on revited plates etc,completeCPRI type testedfabricated out of 3.0mm thick CRCA sheetpainted with epoxy powder coated mat finish pre wired with PVC insulated multistranded copper conductor for controls and monitors , PVCsleeved aluminium strip for connecting MCCBs ,panelsmounted on angle ironframe of 50x50x6 mm thick duly painted and embededembded in PCC 1:3:6, 45 cm belowground level and 15 Cm above ground level and consisting the following and complete all as specified and all as directed by engineer in charge .A )Aluminium bus bar of 100 Amps capacity duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of class “F” class insulators.B )MCCB TPN 415 Volts 50 Hz 63 Amps 25 KA rupturing capacity (Incoming)C )MCB SP 230 Volts 50 Hz 32 Amps outgoing 2 Nos (01 Spare )D )MCB TPN 415 Volts 50 Hz 32 Amp Outgoing7Nos(02 Spare)E ) Multi functional Meter (LED display ) to read KWH ,Amps,Volts and frequency etc of each phase (3 PH,4W IPM 240 V(L-N)5A Class 1 FMF )Indicator LED Type for RYB set of 3 -01 SetG )Indicator LED type for RYB set 3 -01 set .Contactor MNX coil voltage 230 V -01 No (One for street light )Electronic timer switch 240 V AC 40 Supply and fix steel tubular swaged poles type 410 SP-31( 9 meter long) swan neck type complete with CI base plate and finial and single swan neck, including foundation and coping complete Note: Excavationof poles and RFL is inclusive in relevent item. 41 Supply and fixingGate Light Post Top Latern light energy saving enviromently friendly long life aesthetically design with symmetrical light distrubution spun alunimum land scape luminare with high power LED 15 Watts (pole dia 50 MM) 42 Supply and fixingmoulded PVC / SMCJunction boxes out door type, weather proof, of size 255 x 200 x 100 mm to be fixed at the bottom of street light pole 3ph RYB busbar 200 amps capacity complete with suitable clamp , nut, bolt, washers and suitable glands ,to accommodate01 No MCB SP 5 Amps 10 KA, with suitable connectors for incoming and outgoing connections , complete all as specified and directed. 43 Supply and fixingcable route indicator HT 10cm dia made of cast iron 8mm thick fixed on MS angle iron of size 25x 25x 5mm 60cm long complete including fixing necessary excavation in soft/loose soil embedded in PCC 1 : 2 : 4 type C1 block of size 200 x 200 x 150mm and removal of surplus soil and marked as HT cable / joints on circular cast iron plate complete all as specified and as directed 44 Material and labourfor Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe upto 150 MM dia suitable for 0.4mpa working pressure. 45 Sch A Part - XVII:- Cooling Appliances Supply and installation, commissioning of electric driven, single phase refrigerators capacity 385 litres double doorBEE 5 star rated all as specified and directed. 46 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 04 KVA all as specified and directed.. 47 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 01 KVAall as specified and directed. . 48 Sch A Part - XVII:- DG SET Supply , installed and commissioning of Factory assembled Silent DG set with AMF panel of capacity 30 KVA, 24 KW , 1500 RPM , Turbo Charged, water cooled comprising ofsuitable 41.2 BHP Engine with microprocessor based Genset controller with silencer and canopy for soundles mode (sound level not exe level specified by contol pollution board) and alternator both mounted on a common base frame conforming to ISO-3046/BS-5514 andIS-10002 rated for 415 volts 50 cycles , 0.8 Power factor (PF) complete withresidential silencer, AVM pads , battery with its leads, first fill of lub oil and all engine accessories such as self starter, alternator/dynomo with suitable coupling and base frame on foundation as recommended by the manufacture and consisting of other electrical component and maintenance free battey including suitable size of coppeer cable lead with teminal, all mounting accssory and AVM pads all as specified comprising with the following. (Make : Engine : Cummins, Alternator : Stamford./ Kirloskar or equivalaint approved make. 49 A. Engine (a) Vertical multicylinder, cold starting in accordance with BS-5514/IS-10002 at 1500 RPM including the following accessories :-(i) Fuel tank(Suitable for capacity for minimum 12 Hrs run).(ii) Fuel filter(Ore & Micro).(iii) Fuel feed pump(Inline monoblock/PT type) with governor.(iv) Lub oil filter.(v) Lub oil cooler.(vi) Dry type/ol bah type air cleaner.(vii) Exhaust Silencer(Industrial type).(viii) Radiator, Radiator fan & mounting.(ix) Fly wheel with starting ring.(x) Expansion bellow.(xi)Exhaust gas turbocharger.(xii) 12 Volt electric starter with 01 Nos maintenance free battery of suitable capacity.(xiii)Battery charging alternator(xiv)Engine control panel consisting with ON/OFF Start Key,Lub oil pressure guage, Battery charging ammeter,Coolant temp gauge, RPM Meter etc.(xv)Suitable flexible coupling(xvi) Front & Rear engine mounting supports (AVM pads) 50 B. ALTERNATOR(i) Alternator, 3 phase, 415 Volts, 50 Hzs 0.8 PF 1500 RPM self excited, self regulated screen profected, drip proof alternator of capacity 30 KVA conforming to BSS 5000 (part 99) with insulation class H, single bearing and automatic voltage regulator accessoriesC. ACOUSTIC ENCLOSURE(i) Specially design to meet stringent MOEF/CPCB norms of 75 dBA @ 1 mtr at 75% load under free field conditions.(ii) Air inlet louvers specially designed to operate at rated load even at 50 deg C air inlet temp.(iii) Powder coated for long lasting service life and superior finish. (iv) Insulation material meets exacting IS 8183. D.ACCESSORIES(i) Suitable channel frame (ii) Storage battery of suitable capacity as per manufactures instruction mounted on angle iron froame of suitable size as directed.E. CONTROL PANEL(a)The control panel shall be made of CRCA sheet duly fabricated and powder coated and complete with internal wiring, bus bar etc and fitted with the following accessories :-(i) MCCB of suitable capacity as per OEM – 01 No(ii) Digital Ammeter – 01 No(iii) Digital Voltmeter 3 Ph 415 volts– 01 No(iv) Indicating lamps (LED type) (R-Y-B) – 01 set 51 F. AMF PANEL(a)The control panel shall be made of CRCA sheet duly fabricated and powder coated and complete with internal wiring, bus bar etc and fitted with the following accessories :-(i) MCCB of suitable capacity as per OEM(ii) Contractor-01 Nos(ii)Digital Ammeter with suitable CT of size as per OEM(iii) Digital Voltmeter 3 Ph 415 volts as per OEM(iv) Indicating lamps (LED type) (R-Y-B) – 01 sets(v) Relay, timer and other acessories as per manufactor.NOTE(i)Antivibraton mounting pads to be incorported during installation.(ii) PCC Foundation and platform as per manufacters design/recommendation to be followed during installation of DG Set will be measured and paid under relevant item of this BoQ.(iii) Silencer pipe of engine is to be extended out of the building with suitable dia of GI medium grade pipe duly heat insulated with suitable asbestos rope duly claded with plaster of paris rate of which deemed included in the unit rate of Gen set.(iv)Lubricating oil shall be provided by the conractor cost of which deemed to be included in the unit rate of DG Set.(v) Four Nos free serviceing with complete material such as Lubricating oil, coolent, Lub oil filter, diesel filters, Air filter and fan belts etc as per manufacturer recommendation will be deemed included in the unit rate of DG set. 52 Sch A Part - XVII:-HOT WATER SUPPLY Supply and fixingbrass non return valve of 25mm dia(1 inch) for CPVC pipe of size 25 mm bore complete all as specified and directed. 53 Supply and fixingGI pipe tee of 25mm dia (1 inch) for CPVC pipe of size 25 mm bore complete all as specified and directed. 54 Supply and fixing PVC water tank of 1500 ltrs capacity, 100% UV stabilized tank and lid, multiple layer, multi ribbed design, threaded lid and double rid all as specified and directed 55 Supply and fixingRemovable Square mild steel water tank stand of 5.75 feet suitable to place 1500 ltrs PVC water tank 56 Sch A Part - XVII:- Fire alarm detection SystemSupply and fixLED Edge Lit Fire exit signagewith a man running and arrow symbol and stair acrylic, wall mounted 26x16x2 centimeter ,8MM clear tranparent acrylic with batter back up all signs and symbols used as per norms color greenall as specified and directed 57 Supply & Fix Control Console for Fire alarm detection Systemall as specified and directed 58 Supply and fix repeater control panel double loop 230 V AC 2 sounder circuit and 40 fire zone morley IAS protocol upto 5 loop fire alaram control panel all as specified and directed 59 Supply, laying & testing PVC insulated, PVC round sheathed copper conductor (flexiable) industrail cableof size 1.5 sqmm, 2 core, 1100 volts, conforming to IS 694 all as specified and directed 60 Supply and fix cast iron air release valve with two out lets 100 mm dia bore ad fixing up in steel water supply mains all as specified and directed 61 Supply and fixreflex valve with, with by-pass arrangement100 mm dia bore ad fixing up in steel water supply mains with pressure switch all as specified and directed. 62 Supply and fix branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 all as specified and directed 63 Supply anf fixhose reel of 20mm dia and 30meter length conforming to IS 5132 and hose reel arrangement shall conforming to IS 884 all as specified and directed 64 Supply , install wet chemical K type commercial kitchen fire extinguisher system(BS EN 3/NFPA10)of capacity 6 Ltrs with working pressure of 15 bar at 27 degree celsius and maximum service pressure of 1.9 MPaall as specified and as directed

Key Value

Document Fees
INR 3000 /-
EMD
INR 1070000.0 /-
Tender Value
INR 14.90 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail