}

Tender For Modernization Work Under Rdss, 1 Supply For ( 2 X 5 Mva) New 33/11 Kv Substation- Scada Compatible Asper Technical Specifications, Scope Of Works And Approved Drawings 2 Supply& Installation, Testing And Commissioning Of5 Mva Power Transfor, varanasi-Uttar Pradesh

Government Departments has published Tender For Modernization Work Under Rdss, 1 Supply For ( 2 X 5 Mva) New 33/11 Kv Substation- Scada Compatible Asper Technical Specifications, Scope Of Works And Approved Drawings 2 Supply& Installation, Testing And Commissioning Of5 Mva Power Transfor. Submission Date for this Tender is 08-10-2024. Building Work Tenders in varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45496172
Tender For Modernization Work Under Rdss, 1 Supply For ( 2 X 5 Mva) New 33/11 Kv Substation- Scada Compatible Asper Technical Specifications, Scope Of Works And Approved Drawings 2 Supply& Installation, Testing And Commissioning Of5 Mva Power Transfor
Open Tender
Indian
Uttar Pradesh
Varanasi
08-10-2024

Tender Documents

Tender Details

Tender For Modernization Work Under Rdss, 1 Supply for ( 2 X 5 MVA) New 33/11 KV Substation- SCADA Compatible asper technical specifications, scope of works and approved drawings 2 Supply& installation, testing and commissioning of5 MVA Power Transformer 3 Construction of Power Transformer Plinth of size 3.46x4.46 Mtr. having 0.5 Mtr. below ground level and 0.4 Mtr. above ground level. 4 Supply & Erectionof 63KVA, 11/0.415 kV, 3 ph, 50 Hz, ONAN,Aluminiumwound,(Energy Efficiency Level-1) CRGO core, outdoor typeStation Transformer Completely filled with transformer oil asper technical specifications. 5 Supply & Erectionof hot dip Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per ISfor all structural members. As per TS 6 Gantry Foundation 7 Supply & Erecrionof 36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 8 Construction ofPlinth & foundationfor33 kv VCB 9 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,400-200/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 10 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,200-100/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 11 Construction of Plinth & foundationfor33 kV Single Phase CT (3 Nos.) 12 Supply & Erectionof 36 kV, 1-Phase, 33kV/110 volt, Single coreoutdoor type Potential Transformer including accessories etc., complete as per technical specifications.( 1 set=3 no) As per TS 13 Construction ofPlinth & foundation for 33 kV Single PT (3 Nos.) 14 36kV, indoor, Control & Relay panel alongwith E/F & O/C,Mimic Diagram,Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc. complete as per approved drawings & TS: 15 Supply & Erection of33 kV feeder Panel (without diffirential relays) complete As per TS. 16 Supply& Erectionof 33 kV Double Transformer Panel (withdiffirential relay and 5/1 A auxillary CT)complete As per TS . 17 Supply & Erectionof 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch) 18 Supply & Erection of36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch) 19 Construction ofPlinth & foundation for 33 kV isolator 20 Supply & Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete(1 set= 3 Nos.) 21 Construction ofPlinth & foundation for 33 kVLA 22 Supply & Erectionof of9kV, 10kA, 1-ph Station Class LighteningArrester complete (1 Set = 3 Nos.) 23 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit BreakerforIncomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase ,withNumerical Relays & accessories complete as per specifications for transformer breaker protectionwith earth fault, overcurrent . 24 Supply & Erection of12 kV, 1600 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit Breakerforalong with 12 kV, 1-Phase, 25kA, 600-300/5-5 A,3 Nos indoor type Current Transformer, control panel for Bus couplar and required accessories, A-meter, Numerical Relays & accessories complete as per specifications for Bus Coupler protectionwith earth fault, overcurrent . 25 Supply & Erectionof 12 KV 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 26 Supply & Erectionof 24V, 150 AHPb(Lead) Acid battery,withcabinet specifications. 27 Supply & Erection of 24V, 150 AH.Float-cum-Boost Battery Chargerfor230V,1 phase, 50 Hz AC Input Supply as per technical specifications. 28 Supply& Erectionof 24V DCDB complete in all respect suitable for 20 nos.of DC circuit for smooth operation of DC supplyas per technical specifications. 29 Supply & Erection of 415V AC Distribution Board/Panel of sheet stealenclosed cubical floor mounting type for catering auxiliary power supply for Suitable100 KV T/F of the substaion etc. complete 30 Supply & Erection of ACSR Panther Conductor for Bus-Bars & Jumpers/Droppers/Terminations 31 Earthing & Grounding conductor as per Approved Electrical Layoutfor each sub- station with 32 Supply & Erection of75 x 8 mm GI flat. 33 Supply & Erection of 50 x 6 mm GI flat. 34 Supply & Erectionof32 mm dia MS rod 6 m long for earth mat 35 Supply & Erection of40 mm dia.,3000 mm long GI pipe earthelectrode as per Technical Specification 36 33 KV and 11 KV Insulator - Pin, Post and Disc insulators along with G.I. Pin, Hardware & Accessories suitable for Panther conductors as per Technical secifications(All the materials shallbe MShot dip galvanised) 37 Supply & Erectionof 33 KV Post Insulator (1 Set = 2 Nos of 22 KV) 38 Construction ofPlinth & foundation for 33 kVPost Insulator 39 Supply & Erection of 33 KV Disc InsulatorInsulator(1 Set = 4 Nos Disc Insulator 70 KN) 40 Supply & Erection ofHardware fitting for 33 KV Disc Insulator (B&S Type 70 KN) 41 Supply & Erection of33 KV Polymer Pin Insulator with Nut & Bolt . 42 Supply & Erection ofBimetalic Clamps , Al. Connectors, Al. tape etc. complete in all respect as required. 43 Supply & Erectionof Station Lighting System (External) 120 Watt, LEDwith proper illuminationcomplete for switchyard,main gate and sub-station boundry including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. all complte as per applicable TS and approved drawing. (minimum 8 nos on Lighting Poles & 8 nos on structure & control room building ) 44 Supply & Erectionof Station Lighting System (internal) with proper illumination complete forcontrol room building, Incharge room, Battery room, Store room, Washroom, Guard room, portico etc.including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc.and Celling Fan , wall Fan & exhaust fan (Total 8 nos.) all complte as per applicable TS and approved drawing. 45 Supplyof Tool & Plant: Gum Boot- 2 pair, Hand Gloves- 2 pair, Insulated Plier- 2 nos., D E spanner set- 2 sets, Slide Wrench 8 & 12 2 nos each, Torch (Flash Light) 4 cell- 2 nos, Earth Tester - 1 no, Insulation Megger (hand operated) 2500 V-1 no, Tong Tester (Digital)- 1 no, Discharge Rod (1 Set=3 Nos)- 2 Sets, Rubber mat (1.25 Thick) for laying in front of all panels in control room completely 46 Supply & ErectionFire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for controlroom, CO 2 Type of 4.5Kg Capacity4 nos for Control Room, Fire bucketswith Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings 47 11 KV, XLPE, Power cable, aluminiumconductor, stranded 48 Supply of11kv3Cx 300 sqmm (armoured) Cable 49 Supply of11 kv 3Cx 185 sqmm (armoured) Cable 50 Supplyof11 kv3Cx70 Sqmm (armoured) Cable 51 Laying of 11 KV U/G cable includnig cost of sand and bricks 52 Heat Shrinkable jointing kit suitable for 11 kV XLPE 3x300 Sq.mm. cable size 53 Supply & Erection ofHeat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE outdoor 54 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE Indoor 55 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 56 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE outdoor 57 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE Indoor 58 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x70 Sq.mm. cable size 59 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE outdoor 60 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE Indoor 61 Control Cable 62 Supplyof4x2.5 mm sq. 63 Supply ofof 2x2.5 mm sq. 64 Supply of LT Power Cable 3.5Cx95 sq. mm . 65 Laying of Control Cable 66 Furniture items as required 67 Office table Godrej make 68 Office chair Godrej make 69 Godrej Storwel (Almirah) standard size. 70 11kV Feeder Double Pole structure on 11kV STP alongwith fitting 71 Supply & Erectionof 11 Mtr. long Steel Tubulor Pole SP- (410 SP 55). 72 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 73 Supply & Erection of Barbed wire 74 Supply & Erection ofDanger Board 75 Suplly &Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt. 76 Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt. 77 Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 78 Supply & Erection of S/S name board (SMC) with stand. 79 Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS 80 Earth work by mechanical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift:All kinds of soil 81 Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil : 82 Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth. 83 Deduct for not watering the excavated earth for banking 84 Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 85 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 86 CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 87 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 88 CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 89 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 90 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 91 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete 92 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts 93 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 94 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide 95 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 96 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges 97 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 98 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 99 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) 100 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level. 101 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 102 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 103 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 104 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) 105 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand) 106 First class brick laid dry in foundation and plinth as incircular soakpit walls of one brick thickness and 2.0 to 3.0M depthincluding cutting moulding bricks as required including cost ofall materials labour and T&P complete. 107 S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit). 108 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 109 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces 110 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panescomplete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 111 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 112 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 113 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 114 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 115 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 116 Fixing and grouting of trench edging in proper level andalignment including cost of all labour, and T&P etc. required forproper completion of the work but excluding cost of C.C. (labour rates only) . 117 Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge. 118 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. 119 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm 120 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 121 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 122 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 123 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 124 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 125 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 126 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 127 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC 128 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick 129 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 130 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 131 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 132 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 133 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3) 134 Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as. 135 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4) 136 S/F Angle/Batten Holder. 137 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1) 138 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)(DSR E&M 2022 1.27.2) 139 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3) 140 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4) 141 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5) 142 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6) 143 S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit. 144 Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect. 145 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6) 146 Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1) 147 Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make 148 Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect. 149 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. 150 S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 151 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12) 152 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. 153 Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. 154 Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required forproper completion of work. 155 Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc.(CSI No. 19.28) 156 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil 300 mm dia 157 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia 158 Providing and fixing of 150 mm dia PVC pipeof 6 Kg/sqcmwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25) 159 Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. 160 Supply and fixing of 110mm dia PVC. bail plug of heavy qualityincluding all labour material & T&P. 161 Supply and fixing of 160mm dia PVC top plug of heavy qualityincluding all labour material & T&P. 162 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 163 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 164 Supply & fixing of steel wire rope forsubmersible pump including cost of labour, T&P and material required for completion of work.(CSI No. 19.34) 165 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 166 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms 167 Supply & Installation ofsubmersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work.(CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH 168 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes 169 Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser.(CSI No. 19.31)a) for 1 HP pump set single phase 170 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 171 S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect. 172 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes 173 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes 174 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes 175 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore 176 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 177 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 178 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 179 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length 180 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms 181 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 182 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 183 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 184 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989 185 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 186 Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 187 Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etcrequired for proper completion of the work.c)110 mm dia. 188 Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etcrequired for proper completion of the work c) 110 mm dia. 189 Providing and fixing SWR, PVC ( Finolex or equivalent )Coupler including cost of all materials, labour and T&P etcrequired for proper completion of the work. c) 110 mm dia. 190 Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 191 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 192 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 193 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 194 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 195 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 196 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 197 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 198 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 199 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 200 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 201 Supply of Automatic Capacitor Bank as per approved drawings, technical specifications and scope of work (1.98 MVAr With APFC Panel) 202 Supply & Erection of12.65 kV, 1980 kVAr, 3-Phase, 50 C/s, housed in Outdoor Type CRCA panel, Capacitor bank having two variable step of 792 Kvar & one Variable steps of 396 kVAr. Bank shall be complete with Capacitor units of 264/132 kVAr,Aluminium busbars, Epoxy insulators, HT HRC fuse,Surge suppressor etc.with details as follows-(1 )11 KV Alumuniumwound ,Dry type series reactor(a)0.528 KVAr for 792 KVAr step-6 nos. (b)0.264 KVAr for 396 kVAr step-3 nos. (2) 11 kV, 3-Phase Indoor Dry Type RVT-1 nos. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor-3 nos. (4) Indoor Type Automatic Control Unit-1 No. (5) IP 55, outdoor CRCA cubicle panel for accommodating capacitors, series reactors, vacuum contactor, surge supressor etc., along with FRP canopy-1 No. 203 Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(1.98 MVAr HT Capacitor bank) 204 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(1.98 MVAr HT Capacitor bank) 205 Supply & Erectionof Indoor Type Automatic Control Unit(1.98 MVAr HT Capacitor bank) 206 Supply & Erectionof IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(1.98 MVAr HT Capacitor bank) 207 Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(1.98 MVAr HT Capacitor bank) 208 Supply & Layingof 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(1.98 MVAr HT Capacitor bank) 209 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(1.98 MVAr HT Capacitor bank) 210 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit outoor(1.98 MVAr HT Capacitor bank) 211 Supply & Erection 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(1.98 MVAr HT Capacitor bank) 212 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(1.98 MVAr HT Capacitor bank) 213 Casting of Civil foundation(1.98 MVAr HT Capacitor bank) 214 Cable trench for laying of power/control cables.(1.98 MVAr HT Capacitor bank) 215 Supply for ( 1X 10 MVA) New 33/11 KV Substation- SCADA Compatible asper technical specifications, scope of works and approved drawings 216 Supply&installation, testing and commissioning of10 MVA Power Transformer 217 Construction of Power Transformer Plinth of size 3.46x4.46 Mtr. having 0.5 Mtr. below ground level and 0.4 Mtr. above ground level. 218 Supply & Erectionof 63 KVA, 11/0.415 kV, 3 ph, 50 Hz, ONAN,Aluminiumwound, CRGO core, outdoor typeStation Transformer Completely filled with transformer oil asper technical specifications.( Energy Efficiency Level-1) 219 Supply & Erectionof hot dip Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per ISfor all structural members. As per TS 220 GantryFoundation 221 Supply & Erection ofGI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS. 222 Supply & Erecrionof 36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 223 Construction ofPlinth & foundationfor33 kv VCB 224 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,400-200/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 225 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,200-100/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 226 Construction of Plinth & foundationfor33 kV Single Phase CT (3 Nos.) 227 Supply & Erectionof 36 kV, 1-Phase, 33kV/110 volt, Single coreoutdoor type Potential Transformer including accessories etc., complete as per technical specifications.( 1 set=3 no) 228 Construction ofPlinth & foundation for 33 kV Single PT (3 Nos.) 229 36kV, indoor, Control & Relay panel alongwith E/F & O/C,Mimic Diagram,Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc. complete as per approved drawings & TS: 230 Supply & Erection of33 kV feeder Panel (without diffirential relays) complete. 231 Supply& Erectionof 33 kV Transformer Panel (withdiffirential relay and 5/1 A auxillary CT) complete. 232 Supply & Erectionof 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch) 233 Supply & Erection of36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch) 234 Construction ofPlinth & foundation for 33 kVIsolator 235 Supply & Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete(1 set= 3 Nos.) 236 Construction ofPlinth & foundation for 33 kV LA 237 Supply & Erectionof of9kV, 10kA, 1-ph Station Class LighteningArrester complete (1 Set = 3 Nos.) 238 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit BreakerforIncomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase , with Numerical Relays & accessories complete as per specifications for transformer breaker protectionwith earth fault, overcurrent . 239 Supply & Erectionof 12 KV 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 240 Supply & Erectionof 24V, 150 AHPb(Lead) Acid battery,as per technical specifications. 241 Supply & Erection of 24V, 150 AH.Float-cum-Boost Battery Charger with full wave rectification for230V,1 phase, 50 Hz AC Input Supply as per technical specifications. 242 Supply& Erectionof 24V DCDB complete in all respect suitable for 20 nos.of DC circuit for smooth operation of DC supplyas per technical specifications. 243 Supply & Erection of 415V AC Distribution Board/Panel of sheet stealenclosed cubical floor mounting type for catering auxiliary power supply for Suitable100 KV T/F of the substaion etc. complete 244 Supply & Erection of ACSR Panther Conductor for Bus-Bars & Jumpers/Droppers/Terminations 245 Earthing & Grounding conductor as per Approved Electrical Layoutfor each sub- station with 246 Supply & Erection of75 x 8 mm GI flat. 247 Supply & Erection of 50 x 6 mm GI flat. 248 Supply & Erectionof32 mm dia MS rod 6 m long for earth mat 249 Supply & Erection of40 mm dia.,3000 mm long GI pipe earthelectrode as per Technical Specification 250 33 KV and 11 KV Insulator - Pin, Post and Disc insulators along with G.I. Pin, Hardware & Accessories suitable for Panther conductors as per Technical secifications(All the materials shallbe MShot dip galvanised) 251 Supply & Erectionof 33 KV Post Insulator (1 Set = 2 Nos of 22 KV) 252 Construction of Plinth & foundation for 33 kVPost Insulator 253 Supply & Erection of 33 KV Disc InsulatorInsulator(1 Set = 4 Nos Disc Insulator 70 KN) 254 Supply & Erection ofHardware fitting for 33 KV Disc Insulator (B&S Type 70 KN) 255 Supply & Erection of33 KV Polymer Pin Insulator with Nut & Bolt . 256 Supply & Erection ofBimetalic Clamps , Al. Connectors, Al. tape etc. complete in all respect as required. 257 Supply & Erectionof Station Lighting System (External) 120 Watt, LEDwith proper illuminationcomplete for switchyard,main gate and sub-station boundry including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. all complte as per applicable TS and approved drawing. (minimum 8 nos on Lighting Poles & 8 nos on structure & control room ) 258 Supply & Erectionof Station Lighting System (internal) with proper illumination complete forcontrol room building, Incharge room, Battery room, Store room, Washroom, Guard room, portico etc.including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc.and Celling, wall Fan & exhast fan (Total 8 nos.) all complte as per applicable TS and approved drawing. 259 Supply & Erection of Tool & Plant: Gum Boot- 2 pair, Hand Gloves- 2 pair, Insulated Plier- 2 nos., D E spanner set- 2 sets, Slide range 8 & 12 2 nos each, Torch (Flash Light) 4 cell- 2 nos, Earth megger- 1 no, Insulation Megger (hand operated) 1000 V-1 no, Tong Tester (Digital)- 1 no, Discharge Rod (1 Set=3 Nos)- 6 Sets, Rubber mat (1.25 Thick) for laying in front of all panels in control room completely 260 Supply & ErectionFire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for controlroom, CO 2 Type of 4.5Kg Capacity4 nos for Control Room, Fire bucketswith Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings 261 11 KV, XLPE, Power cable, aluminiumconductor, stranded 262 Supply of11kv3Cx 300 sqmm (armoured) Cable 263 Supply of11 kv 3Cx 185 sqmm (armoured) Cable 264 Supplyof11 kv3Cx70 Sqmm(armoured) Cable 265 Laying of 11 KV U/G cable includnig cost of sand and bricks 266 Heat Shrinkable jointing kit suitable for 11 kV XLPE 3x300 Sq.mm. cable size 267 Supply & Erection ofHeat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE outdoor 268 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE Indoor 269 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 270 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE outdoor 271 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE Indoor 272 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x70 Sq.mm. cable size 273 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE outdoor 274 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE Indoor 275 Control Cable 276 Supplyof4x2.5 mm sq. 277 Supply ofof 2x2.5 mm sq. 278 Supply of LT Power Cable 3.5Cx95 sq. mm. 279 Laying of Control Cable 280 11kV Feeder Double Pole structure on 11kV STP alongwith fitting (as per Annex-9) 281 Supply & Erectionof 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55) 282 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 283 Suplly &Erection of 11KV TPMO switch with fixing clamps 284 Suplly &ErectionBarbed wire 285 Suplly &Erection of DangerBoard 286 Supply & Erection of 11 KV fuse set with fixing clamps 287 Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 288 Supply & Erection of S/S name board (SMC) with stand. 289 Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS 290 Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift:All kinds of soil 291 Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil : 292 Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth. 293 Deduct for not watering the excavated earth for banking 294 Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 295 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 296 CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 297 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 298 CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 299 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 300 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 301 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete 302 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts 303 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 304 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide 305 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 306 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges 307 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 308 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 309 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) 310 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level. 311 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 312 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 313 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 314 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) 315 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand) 316 First class brick laid dry in foundation and plinth as incircular soakpit walls of one brick thickness and 2.0 to 3.0M depthincluding cutting moulding bricks as required including cost ofall materials labour and T&P complete. 317 S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit). 318 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 319 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces 320 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panescomplete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 321 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 322 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 323 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 324 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 325 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 326 Fixing and grouting of trench edging in proper level andalignment including cost of all labour, and T&P etc. required forproper completion of the work but excluding cost of C.C. (labour rates only) . 327 Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge. 328 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. 329 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm 330 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 331 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 332 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 333 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 334 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 335 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 336 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 337 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC 338 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick 339 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 340 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 341 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 342 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 343 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3) 344 Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as. 345 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4) 346 S/F Angle/Batten Holder. 347 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1) 348 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)(DSR E&M 2022 1.27.2) 349 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3) 350 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4) 351 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5) 352 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6) 353 S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit. 354 Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect. 355 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6) 356 Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1) 357 Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make 358 Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect. 359 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. 360 S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 361 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12) 362 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. 363 Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. 364 Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required forproper completion of work. 365 Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc.(CSI No. 19.28) 366 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil 300 mm dia 367 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia 368 Providing and fixing of 150 mm dia PVC pipeof 6 Kg/sqcmwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25) 369 Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. 370 Supply and fixing of 110mm dia PVC. bail plug of heavy qualityincluding all labour material & T&P. 371 Supply and fixing of 160mm dia PVC top plug of heavy qualityincluding all labour material & T&P. 372 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 373 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 374 Supply & fixing of steel wire rope forsubmersible pump including cost of labour, T&P and material required for completion of work.(CSI No. 19.34) 375 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 376 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms 377 Supply & Installation ofsubmersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work.(CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH 378 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes 379 Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser.(CSI No. 19.31)a) for 1 HP pump set single phase 380 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 381 S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect. 382 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes 383 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes 384 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes 385 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore 386 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 387 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 388 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 389 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length 390 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms 391 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 392 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 393 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 394 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989 395 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 396 Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 397 Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etcrequired for proper completion of the work.c)110 mm dia. 398 Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etcrequired for proper completion of the work c) 110 mm dia. 399 Providing and fixing SWR, PVC ( Finolex or equivalent )Coupler including cost of all materials, labour and T&P etcrequired for proper completion of the work. c) 110 mm dia. 400 Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 401 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 402 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 403 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 404 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 405 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 406 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 407 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 408 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 409 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 410 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 411 3.96 MVAr With APFC Panel As per TS 412 Supply & Erection of 12.65 kV, 3960 kVAr, 3-Phase, 50 C/shoused in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set 413 Supply &Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank) 414 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank) 415 Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank) 416 Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank) 417 Supply& Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank) 418 Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank) 419 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank) 420 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank) 421 Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank) 422 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(3.96 MVAr HT Capacitor bank) 423 Casting of Civil foundation(3.96 MVAr HT Capacitor bank) 424 Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank) 425 Supply for ( 2X 10 MVA) New 33/11 KV Substation- SCADA Compatible asper technical specifications, scope of works and approved drawings 426 Supply& installation, testing and commissioning of10 MVA Power Transformer 427 Construction of Power Transformer Plinth of size 3.46x4.46 Mtr. having 0.5 Mtr. below ground level and 0.4 Mtr. above ground level. 428 Supply & Erectionof 63 KVA, 11/0.415 kV, 3 ph, 50 Hz, ONAN,Aluminiumwound, CRGO core, outdoor typeStation Transformer Completely filled with transformer oil asper technical specifications. Energy Efficiency Level-1 429 Supply & Erectionof hot dip Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per IS:4759 for all structural members. 3.5mm spring washers are to be used under each structural steel shall conform to IS 2026. All weld shall be 6mm filled weld unless specified otherwise.Anchor plate shall be of relevant IS 430 GantryFoundation 431 Supply & Erection ofGI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS. All bolts & nuts, washers etc. shall be galvanizedas per IS:4759. 3.5mm spring washers are to be used under each nut shall conform to IS 2026.All nuts and bolts shall be of property class 5.6 of IS 1367. Plain washers shall be as per IS 2016 & spring washers shall be IS: 3063 and foundation bolts, shall be of relevant IS 432 Supply & Erecrionof 36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 433 Construction ofPlinth & foundation for 33 kVVCB. 434 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,400-200/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 435 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,200-100/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 436 Construction ofPlinth & foundation for 33 kVCT . 437 Supply & Erectionof 36 kV, 1-Phase, 33kV/110 volt, Single coreoutdoor type Potential Transformer including accessories etc., complete as per technical specifications.( 1 set=3 no) 438 Construction ofPlinth & foundation for 33 kVPT 439 36kV, indoor, Control & Relay panel alongwith E/F & O/C,Mimic Diagram,Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc. complete as per approved drawings & TS: 440 Supply & Erection of33 kV feeder Panel (without diffirential relays) complete. 441 Supply& Erectionof 33 kV Double Transformer Panel (withdiffirential relay and 5/1 A auxillary CT)complete As per TS. 442 Supply & Erectionof 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch) 443 Supply & Erection of36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch) 444 Construction ofPlinth & foundation for 33 kVIsolator . 445 Supply & Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete(1 set= 3 Nos.) 446 construction ofPlinth & foundation for 33 kVLA 447 Supply & Erection of of9kV, 10kA, 1-ph Station Class LighteningArrester complete (1 Set = 3 Nos.) 448 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit BreakerforIncomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase , Numerical Relays & accessories complete as per specifications for transformer breaker protectionwith earth fault, overcurrent . 449 Supply & Erection of12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit Breakerforalong with 12 kV, 1-Phase, 25kA, 600-300/5-5 A,3 Nos indoor type Current Transformer, control panel for Bus couplar and required accessories, A-meter, Numerical Relays & accessories complete as per specifications for Bus Coupler protectionwith earth fault, overcurrent . 450 Supply & Erectionof 12 KV 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 451 Supply & Erectionof 24V, 150 AHPb(Lead) Acid battery As per TS. 452 Supply & Erection of 24V, 150 AH.Float-cum-Boost Battery Chargerfor230V,1 phase, 50 Hz AC Input Supply as per technical specifications. 453 Supply& Erectionof 24V DCDB complete in all respect suitable for 20 nos.of DC circuit for smooth operation of DC supplyas per technical specifications. 454 Supply & Erection of 415V AC Distribution Board/Panel of sheet stealenclosed cubical floor mounting type for catering auxiliary power supply for Suitable100 KV T/F of the substaion etc. complete 455 Supply & Erection of ACSR Panther Conductor for Bus-Bars & Jumpers/Droppers/Terminations 456 Earthing & Grounding conductor as per Approved Electrical Layoutfor each sub- station with 457 Supply & Erection of75 x 8 mm GI flat. 458 Supply & Erection of 50 x 6 mm GI flat. 459 Supply & Erectionof32 mm dia MS rod 6 m long for earth mat 460 Supply & Erection of40 mm dia.,3000 mm long GI pipe earthelectrode as per Technical Specification 461 33 KV and 11 KV Insulator - Pin, Post and Disc insulators along with G.I. Pin, Hardware & Accessories suitable for Panther conductors as per Technical secifications(All the materials shallbe MShot dip galvanised) 462 Supply & Erectionof 33 KV Post Insulator (1 Set = 2 Nos of 22 KV) 463 Construction of Plinth & foundation for 33 kVPost Insulator 464 Supply & Erection of 33 KV Disc InsulatorInsulator(1 Set = 4 Nos Disc Insulator 70 KN) 465 Supply & Erection ofHardware fitting for 33 KV Disc Insulator (B&S Type 70 KN) 466 Supply & Erection of33 KV Polymer Pin Insulator with Pin 467 Supply & Erection ofBimetalic Clamps , Al. Connectors, Al. tape etc. complete in all respect as required. 468 Supply & Erectionof Station Lighting System (External) 120 Watt, LEDwith proper illuminationcomplete for switchyard,main gate and sub-station boundry including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. all complte as per applicable TS and approved drawing. (minimum 8 nos on Lighting Poles & 8 nos on structure & control room ) 469 Supply & Erectionof Station Lighting System (internal) with proper illumination complete forcontrol room building, Incharge room, Battery room, Store room, Washroom, Guard room, portico etc.including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc.and Celling, wall Fan & exhast fan (Total 8 nos.) all complte as per applicable TS and approved drawing. 470 Supplyof Tool & Plant: Gum Boot- 2 pair, Hand Gloves- 2 pair, Insulated Plier- 2 nos., D E spanner set- 2 sets, Slide range 8 & 12 2 nos each, Torch (Flash Light) 4 cell- 2 nos, Earth megger- 1 no, Insulation Megger (hand operated) 1000 V-1 no, Tong Tester (Digital)- 1 no, Discharge Rod (1 Set=3 Nos)- 6 Sets, Rubber mat (1.25 Thick) for laying in front of all panels in control room completely 471 Supply Fire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for controlroom, CO 2 Type of 4.5Kg Capacity4 nos for Control Room, Fire bucketswith Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings 472 11 KV, XLPE, Power cable, aluminiumconductor, stranded 473 Supply of11kv3Cx 300 sqmm (armoured) Cable 474 Supply of11 kv 3Cx 185 sqmm (armoured) Cable 475 Supplyof11 kv3Cx70 Sqmm (armoured) Cable 476 Laying of 11 KV U/G cable includnig cost of sand and bricks 477 Heat Shrinkable jointing kit suitable for 11 kV XLPE 3x300 Sq.mm. cable size 478 Supply & Erection ofHeat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE outdoor 479 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE Indoor 480 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 481 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE outdoor 482 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE Indoor 483 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x70 Sq.mm. cable size 484 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE outdoor 485 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE Indoor 486 Control Cable 487 Supplyof4x2.5 mm sq. 488 Supply ofof 2x2.5 mm sq. 489 Supplyof LT Power Cable 3.5Cx95 sq. mm. 490 Laying of Control Cable 491 11kV Feeder Double Pole structure on 11kV STP alongwith fitting (as per Annex-9) 492 Supply & Erectionof 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55) 493 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 494 Supply & Erectionof Barbd wire 495 Supply & ErectionofDanger Board 496 Suplly &Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt. 497 Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt. 498 Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 499 Supply & Erection of S/S name board (SMC) with stand. 500 Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS 501 Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift:All kinds of soil 502 Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil : 503 Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth. 504 Deduct for not watering the excavated earth for banking 505 Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 506 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 507 CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 508 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 509 CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 510 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 511 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 512 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete 513 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts 514 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 515 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide 516 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 517 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges 518 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 519 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 520 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) 521 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level. 522 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 523 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 524 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 525 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) 526 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand) 527 First class brick laid dry in foundation and plinth as incircular soakpit walls of one brick thickness and 2.0 to 3.0M depthincluding cutting moulding bricks as required including cost ofall materials labour and T&P complete. 528 S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit). 529 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 530 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces 531 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panescomplete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 532 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 533 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 534 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 535 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 536 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 537 Fixing and grouting of trench edging in proper level andalignment including cost of all labour, and T&P etc. required forproper completion of the work but excluding cost of C.C. (labour rates only) . 538 Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge. 539 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. 540 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm 541 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 542 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 543 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 544 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 545 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 546 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 547 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 548 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC 549 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick 550 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 551 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 552 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 553 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 554 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3) 555 Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as. 556 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4) 557 S/F Angle/Batten Holder. 558 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1) 559 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)(DSR E&M 2022 1.27.2) 560 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3) 561 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4) 562 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5) 563 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6) 564 S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit. 565 Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect. 566 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6) 567 Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1) 568 Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make 569 Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect. 570 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. 571 S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 572 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12) 573 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. 574 Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. 575 Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required forproper completion of work. 576 Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc.(CSI No. 19.28) 577 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil 300 mm dia 578 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia 579 Providing and fixing of 150 mm dia PVC pipeof 6 Kg/sqcmwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25) 580 Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. 581 Supply and fixing of 110mm dia PVC. bail plug of heavy qualityincluding all labour material & T&P. 582 Supply and fixing of 160mm dia PVC top plug of heavy qualityincluding all labour material & T&P. 583 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 584 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 585 Supply & fixing of steel wire rope forsubmersible pump including cost of labour, T&P and material required for completion of work.(CSI No. 19.34) 586 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 587 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms 588 Supply & Installation ofsubmersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work.(CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH 589 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes 590 Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser.(CSI No. 19.31)a) for 1 HP pump set single phase 591 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 592 S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect. 593 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes 594 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes 595 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes 596 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore 597 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 598 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 599 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 600 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length 601 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms 602 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 603 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 604 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 605 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989 606 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 607 Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 608 Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etcrequired for proper completion of the work.c)110 mm dia. 609 Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etcrequired for proper completion of the work c) 110 mm dia. 610 Providing and fixing SWR, PVC ( Finolex or equivalent )Coupler including cost of all materials, labour and T&P etcrequired for proper completion of the work. c) 110 mm dia. 611 Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 612 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 613 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 614 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 615 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 616 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 617 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 618 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 619 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 620 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 621 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 622 3.96 MVAr With APFC Panel As per TS 623 Supply & Erection of 12.65 kV, 3960 kVAr, 3-Phase, 50 C/shoused in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set 624 Supply &Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank) 625 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank) 626 Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank) 627 Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank) 628 Supply& Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank) 629 Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank) 630 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank) 631 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank) 632 Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank) 633 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(3.96 MVAr HT Capacitor bank) 634 Casting of Civil foundation(3.96 MVAr HT Capacitor bank) 635 Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank) 636 Supply for New 33/11 KV Indoor GIS Type Substation- SCADA Compatible asper technical specifications, scope of works and approved drawings 637 Supply & installation, testing and commissioning of 10 MVA 33/11 kV Transformer with all complete assesories as per TS 638 Construction of Plinth & Foundation for10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS( On As it is where it is basis) 639 Supply& Erection of 33 KV GIS Panels with 2 line bays, 2 transformer bays, 1 bus coupler bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. 640 Supply & Erection of 11 KV GIS Panels with 6 line bays, 2 transformer bays, 1 station transformer bay & 1 bus coupler bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section. 641 Supply& Erection of 24 V, 150AH,Pb(Lead) Acidtype battery setscomplete. 642 Supply& Erecion of Float-cum-boost battery charger (SMPS based ) with full wave , full control rectification, 50Hz input voltage for charging 24V, 150 AH Battery alongwith DCDB, connectors etc. complete and connection with 24 V , 150 AH Battery set and single phase AC input supply. 643 Supply& Erection of 415V AC Distribution Board/Panel of sheet stealenclosed cubical floor mounting type for catering auxiliary power supply of the substaion etc. complete 644 Supply & Erectionof 63KVA, 11 kV/0.415 kv Station Transformer alongwith allaccessories as per TS.Energy Efficiency Level-1 645 Supply& Erection of40mm dia 3000mm long GI Pipe (Medium Grade) earth electrodes & other accessories for treated earth erection is including of Excavation and other associated activities as per TS. 646 Supply& Erection of 75x6 mm Galvanized flat for raiser for earthing as per TS 647 Supply& Erection of 30 KV, 1 Phase, 10KA LA with all accessories as per TS. 648 Supply& Erection of 9 KV, 1 Phase, 10KA LA with all accessories as per TS. 649 Supply& Layingof 3Cx300 sqmm. 11 KV cable (Panel to Transformer- 1 Run) with cable tray. 650 Supply& Laynibg of 3Cx400 sqmm. 33 KV cable (Panel to Transformer- 2 Run) with cable tray. 651 Suppy & Laying of LT Power Cable 3.5Cx95 sq. mm. 652 Supply& Laying of Control Cable of 2 core 2.5 sq. mm copper cable with cable tray and associated items 653 Supply& Laynibgof Control Cable of 4 core 2.5 sq. mm copper cable with cable tray associated items 654 Supply & Laying of Control Cable of 10 core 2.5 sq. mm copper cable with cable tray associated items 655 Supply of Fire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for controlroom, CO 2 Type of 4.5Kg Capacity4 nos for Control Room, Fire bucketswith Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings 656 Supply of Synthetic Rubber mats as per IS 15652 in control room 2.5 mm thik 657 Supply& Erectionof 11 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 300 sqmm 658 Supply& Erectionof 33 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 400 sqmm(Incoming) 659 Supply & Erection of 11KV XLPE Cable(3x300 sq.mm.) Heat Shrinkable Jointing kit outdoor 660 Supply & Erection of 33KV XLPE Cable(3x400 sq.mm.) Heat Shrinkable Jointing kit outdoor 661 Supply& Erection of Complete lighting system for control room building,main gate and substation boundary including fans as per detailed Technical Specifications. 662 Supply & Erectionof 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55) 663 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 664 Supply & Erectionof Barbd wire 665 Supply & ErectionofDanger Board 666 Suplly &Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt. 667 Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt. 668 Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 669 Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS 670 Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift:All kinds of soil 671 Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil : 672 Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth. 673 Deduct for not watering the excavated earth for banking 674 Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 675 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 676 CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 677 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 678 CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 679 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 680 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 681 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete 682 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts 683 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 684 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide 685 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 686 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges 687 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 688 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 689 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) 690 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level. 691 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 692 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 693 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 694 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) 695 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand) 696 First class brick laid dry in foundation and plinth as incircular soakpit walls of one brick thickness and 2.0 to 3.0M depthincluding cutting moulding bricks as required including cost ofall materials labour and T&P complete. 697 S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit). 698 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 699 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces 700 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panescomplete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 701 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 702 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 703 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 704 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 705 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 706 Fixing and grouting of trench edging in proper level andalignment including cost of all labour, and T&P etc. required forproper completion of the work but excluding cost of C.C. (labour rates only) . 707 Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge. 708 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. 709 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm 710 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 711 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 712 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 713 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 714 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 715 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 716 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 717 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC 718 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick 719 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 720 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 721 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 722 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 723 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3) 724 Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as. 725 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4) 726 S/F Angle/Batten Holder. 727 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1) 728 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)(DSR E&M 2022 1.27.2) 729 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3) 730 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4) 731 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5) 732 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6) 733 S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit. 734 Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect. 735 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6) 736 Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1) 737 Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make 738 Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect. 739 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. 740 S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 741 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12) 742 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. 743 Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. 744 Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required forproper completion of work. 745 Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc.(CSI No. 19.28) 746 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil 300 mm dia 747 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia 748 Providing and fixing of 150 mm dia PVC pipeof 6 Kg/sqcmwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25) 749 Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. 750 Supply and fixing of 110mm dia PVC. bail plug of heavy qualityincluding all labour material & T&P. 751 Supply and fixing of 160mm dia PVC top plug of heavy qualityincluding all labour material & T&P. 752 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 753 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 754 Supply & fixing of steel wire rope forsubmersible pump including cost of labour, T&P and material required for completion of work.(CSI No. 19.34) 755 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 756 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms 757 Supply & Installation ofsubmersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work.(CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH 758 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes 759 Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser.(CSI No. 19.31)a) for 1 HP pump set single phase 760 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 761 S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect. 762 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes 763 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes 764 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes 765 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore 766 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 767 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 768 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 769 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length 770 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms 771 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 772 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 773 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 774 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989 775 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 776 Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 777 Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etcrequired for proper completion of the work.c)110 mm dia. 778 Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etcrequired for proper completion of the work c) 110 mm dia. 779 Providing and fixing SWR, PVC ( Finolex or equivalent )Coupler including cost of all materials, labour and T&P etcrequired for proper completion of the work. c) 110 mm dia. 780 Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 781 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 782 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 783 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 784 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 785 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 786 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 787 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 788 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 789 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 790 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 791 Augmentationl Power Transformers( 5 to 10 MVA) SCADA Compatible asper technical specifications, scope of works and approved drawings 792 Supply &installation, testing and commissioning of10 MVA33/11 kV, 3 ph, 50 Hz, ONAN,Cu Wound, Outdoor Conventional type PowerTransformer with off load tap charger ( completely field with oil) as per TS 793 Supply & Erectoion ofMS Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per IS:4759 for all structural members. 3.5mm spring washers are to be used under each structural steel shall conform to IS 2026. All weld shall be 6mm filled weld unless specified otherwise.Anchor plat shall be of relevant IS 794 GI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS. All bolts & nuts, washers etc. shall be galvanizedas per IS:4759. 3.5mm spring washers are to be used under each nut shall conform to IS 2026.All nuts and bolts shall be of property class 5.6 of IS 1367. Plain washers shall be as per IS 2016 & spring washers shall be IS: 3063 and foundation bolts, shall be of relevant IS 795 Supply & Erection of 36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 796 Construction ofPlinth & foundation for 33 kVVCB 797 Supply & Erectionof 36kV, 1-Phase, 25kA/3 seconds,200-100/1-1 Amps ( having 3 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications. 798 Supply& Erectionof 33 kV SingleTransformer Panel (withdiffirential relay and 5/1 A auxillary CT)complete As per TS . 799 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit BreakerforIncomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type 3 core Current Transformer, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase ,Numerical Relays & accessories complete as per specifications for transformer breaker protectionwith earth fault, overcurrent . 800 Supply & Erection of 12 KV, 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 801 11 KV, XLPE, Power cable, aluminiumconductor, stranded 802 Supply of 3Cx 300 sqmm (armoured) 803 Supply of 3Cx 185 sqmm (armoured) 804 Laying of 11 KV U/G cable includnig cost of sand and bricks 805 Cable termination kit suitable for termination in transformer cable box/breaker panel/ outdoor 11 KV terminals complete with all accessories etc 806 Supply & ErectionTermination kit3Cx 300 sqmm outdoor 807 Supply & ErectionTermination kit3Cx 300 sqmm indoor 808 Supply & Erection of Termination kit3Cx 185 sqmmoutdoor 809 Supply & Erection of Termination kit3Cx 185 sqmm Indoor 810 Control Cable 811 Supplyof4x2.5 mm sq. 812 Supply ofof 2x2.5 mm sq. 813 Laying of Control Cable 814 Dismantaling &Transportation from existing site to Store,Installation, Erection, Testing and Commisiioning of 5/8 MVAPower Transformerswithsuitable Clamps, Connectors, bolts nuts and washers of Brassetcas required with 2 sets each of body & neutral earthing with 50x8 mm GS Strip as per TS completely required for commissioning. 815 Modification of existing Power Transformer foundation required for installation and commissionig of augmented 5/10 MVA Power Transformers completely as per TS. (As per requirement) 816 Additional 5 MVA & 10 MVA Power Transformers SCADA Compatible asper technical specifications, scope of works and approved drawings 817 Supply &installation, testing and commissioning of 5 MVA Power Transformer 818 Supply &installation, testing and commissioning of 10 MVA Power Transformer 819 Construction of Plinth & Foundation for 10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS( On As it is where it is basis) 820 Construction of Plinth & FoundationFoundation for 5 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS( On As it is where it is basis) 821 Supply & Erectoion ofMS Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per IS:4759 for all structural members. 3.5mm spring washers are to be used under each structural steel shall conform to IS 2026. All weld shall be 6mm filled weld unless specified otherwise.Anchor plat shall be of relevant IS 822 Supply & Erection of GI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS. All bolts & nuts, washers etc. shall be galvanizedas per IS:4759. 3.5mm spring washers are to be used under each nut shall conform to IS 2026.All nuts and bolts shall be of property class 5.6 of IS 1367. Plain washers shall be as per IS 2016 & spring washers shall be IS: 3063 and foundation bolts, shall be of relevant IS 823 Gantry Foundation 824 Supply & Erecrionof 36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 825 Construction ofPlinth & foundation for 33 kVVCB 826 Supply & Erection of36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch) 827 Supply & Erection of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch) 828 Construction ofPlinth & foundation for 33 kVIsolator 829 Supply & Erectionof 30kV, 10kA, 1-ph Station Class Lightening Arrester complete(1 set= 3 Nos.) 830 Construction ofPlinth & foundation for 33 kVLA 831 Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds,400-200/1-1 Amps ( having 3 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 832 Construction ofPlinth & foundation for 33 kVCT 833 Supply & Erection of 33 kV Transformer Panel (withdiffirential relay and 5/1 A auxillary CT)complete 834 Supply & Erection 11 KV VCB Switchgears 835 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit BreakerforIncomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase , , Numerical Relays & accessories complete as per specifications for transformer breaker protectionwith earth fault, overcurrent . 836 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit Breakerforalong with 12 kV, 1-Phase, 25kA, 600-300/5-5 A,3 Nos indoor type Current Transformer, control panel for Bus couplar and required accessories, A-meter, Numerical Relays & accessories complete as per specifications for Bus Coupler protectionwith earth fault, overcurrent . 837 Supply & Erectionof 12 KV 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 838 11 KV 3 Core Al. XLPE Insulated Cable 839 Supply of 3x300mm sq. 840 Supplyof 3x185mm sq. 841 Laying of 11 KV U/G cable includnig cost of sand and bricks 842 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x300 Sq.mm. cable size 843 Supply & ErectionTermination kit3Cx 300 sqmm outdoor 844 Supply & Erection of Termination kit3Cx 300 sqmm Indoor 845 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 846 Supply & ErectionTermination kit3Cx 185sqmm outdoor 847 Supply & Erection of Termination kit3Cx 185 sqmm Indoor 848 Control Cable 849 Supply & Laying 4x2.5 mm sq. 850 Supply & Laying 2x2.5 mm sq. 851 Earthing of substation complete as per specification 852 Supply & Erection of75 x 8 mm GI flat. 853 Supply & Erection of 50 x 6 mm GI flat. 854 Supply & Erectionof32 mm dia MS rod 6 m long for earth mat 855 Supply & Erection of40 mm dia.,3000 mm long GI pipe earthelectrode as per Technical Specification 856 Supply & Erectionof 33 KV Post Insulator (1 Set = 2 Nos of 22 KV) 857 Construction ofPlinth & foundation for 33 kVPost Insulator 858 Supply & Erection of 33 KV Disc InsulatorInsulator(1 Set = 4 Nos Disc Insulator 70 KN) 859 Supply & Erection ofHardware fitting for 33 KV Disc Insulator (B&S Type 70 KN) 860 Supply & Erection of33 KV Polymer Pin Insulator with Nut & Bolt . 861 Supply & Erection ofBimetalic Clamps , Al. Connectors, Al. tape etc. complete in all respect as required. 862 11kV Feeder Double Pole structure on 11kV STP alongwith fitting 863 Supply & Erectionof 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55) 864 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 865 Supply &Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt. 866 Supply &Erection of Barbed wire 867 Supply &Erection ofAdnger Board 868 Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt. 869 Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 870 conversion of Existing substations to GIS substations with Increasing capacity and One no E-House additional substation establish SCADA compatibility( 2x10 MVA -2Nos ,3x10 MVA-1 No & 4x10 MVA2 nos 871 Supply & installation & Commissioning of 10 MVA 33/11 kV Transformer with all complete assesories as per TS 872 Construction of Plinth &Foundation for 10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS 873 Supply & Erection of 33 KV GIS incomer Panels , all complete with numerical relays, facility for data transmission and remote control . Ap per TS 874 Supply & Erection of 33 KV GIS outgoing Panels , all complete with numerical relays, facility for data transmission and remote control .As per TS 875 Supply& Erectionof 33 KV GIS bus couplerPanels , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc.As per TS 876 Supply & Erection of 11 KV GIS incomerPanels with , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section. 877 Supply & Erection of 11 KV GISOutgoing Panels with , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section. 878 Supply & Erection of 11 KV GISBus couplerPanels with , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section. 879 Supply & Erection of40mm dia 3000mm long GI Pipe (Medium Grade) earth electrodes & other accessories as per TS. 880 Supply& Erectionof 60x8 mm Galvanized flat for raiser for earthing as per TS 881 Supply& Layingof 3Cx400 sqmm. 33 KV cable (Panel to Transformer- 1 Run) with cable tray. 882 Supply& Layingof 3Cx300 sqmm. 11 KV cable (Panel to Transformer- 2 Run) with cable tray. 883 Supply & Laying of Control Cable of 2 core 2.5 sq. mm copper cable with cable tray and associated items 884 Supply& Laying of Control Cable of 4 core 2.5 sq. mm copper cable with cable tray associated items 885 Supply & Laying of Control Cable of 10 core 2.5 sq. mm copper cable with cable tray associated items 886 Supply & Erectionof 11 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 300 sqmm 887 Supply & Erection of 33 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 400 sqmm(Incoming) 888 Supply & Erection of 33KV XLPE Cable (3x400 Sq.mm.)outdoor Heat Shrinkable Termination kit boxes mounted. 889 Supply & Erection of 11KV XLPE Cable (3x300 Sq.mm.)outdoor Heat Shrinkable Termination kit boxes mounted. 890 Dismentling of existing 33 KV&11 Panelincluding storage, handling, insurance, loading, unloading, transportation to store of Utility as per the direction of Engineer-in-charge with propoer accounting as per the inventory. 891 Dismentling of existing 33 KVisolator,CT ,PT &CBwith structure including storage, handling, insurance, loading, unloading, transportation to store of Utility as per the direction of Engineer-in-charge with propoer accounting as per the inventory. 892 Dismentling of existing 33 KVBay with structure including storage, handling, insurance, loading, unloading, transportation to store of Utility as per the direction of Engineer-in-charge with propoer accounting as per the inventory. 893 E-House Substation establish SCADA compatibility ( 2x10MVA) 894 Supply , installation, testing and comrnissiong of 10 MVA Power Transformer,33/11 kV, 3 ph, 50 Hz, ONAN,Cu Wound, Outdoor Conventional type PowerTransformer with off load tap charger ( completely field with oil) as per TS perthe specifications. The bansformer shall be complete with all accessories shall be provided with cable box termination arrangement on HV & LV side. 895 Supply, installation, testing and commissioning of Pre-fabricated Containerized Substation shall made of GI (2mm thick for load bearing and 1.5mm for non load bearing members) having IP 54 enclosurewith 50mm rockwool 2hr Fire rated thermal insulation Along witha. 33kV Indoor Primary GIS as per TS ( 2 Incomer VCB +1 Bus Caupler +2 Outgoing VCB for 10 MVA Transformer) — 1Setb. llkV Indoor Primary GIS as per TS ( 2 Incomer VCB + 1Bus Caupler +6 Outgoing VCB)-1 Setc. 1No Entry/Exit door Provision for E-House. 1 door shall be suitable for equipment entry from inside onlyd. Battery Bank 48VDC150 AH - 1 Sete. Dual Float cum Boost Battery Charger suitable for 48 V DC, 80 A ( Auto and Manual)-lNo.f. ACDB - 1 Setg. DCDB- 1 seth. Fire Alarm System & Fire Extinguisher(Co2 type) - 1 Seti. AC system (N+1) & AC Control panel - 1 Setj. LT power & control cabling within the container equipmentk. Station earthing grid internal to Container.l. Lightning protection for Metalliccontainer .m. Ilumination System normal & emergency (48V DC) lighting, Lighting Panels, switches and sockets.n. Survillance system complete in all respects(with data backup facilty for 60days)camera 6nos i.e. 2Nos for covering entrance, 2Nos for internal area & 2Nos for acess control system withacess cardo. Metallic container with doors with access control, access platforms.p. Supply of termination kits for 33kV & llKV GIS & termination of cables at site.q. Rubber Insulation mats — As required.Size of Container should be 15 meter X 4.5Meter with sufficient provision for acess (max)The enclosure shall containall the indoor equipments like 33KV GIS, llKV GIS, ACDB,DCDB,RTU panel, RTCC panel, banery chargers, Lightining system, Fire safety system as per the tender specifications.The Container should have followingA)33kv Indoor Gas Insulated Switchgear Panel 1250 A, 31.5KA/3sec which consists of 2 No Line feeder,1 Bus Caupler, 2No transformer feeder( 9 Panels GIS BOARD) as per the enclosed Technical specifications.Internal arc tested panel as per IAC AFLR 31.5 kA for 1sec.TheGIS shall be 3 phase combined and single bus type. CT ratio shall be 400/1+1+1+1 A and PT shall be 33000/sqrt3 Volt/110/sqrt3 Volt.Vacuum Circuit breaker, numerical relays having IEC 61850 protocoland multifunctional metersfor SCADA compatibility as per atmched technical specification.All the GIS panels shall be operated and monitored through SCADA. B)11kv Indoor Gas Insulated Switchgear Panel1250A, 25 KA/3sec which consists of 1No Line feeder,2 No Substation transformerfeeder, 6 Nos Outgoing feeders(9 Panel GIS BOARD)as per the enclosed Technical specifications.Internal arc tested panel as per IAC AFLR 25 kA for1 sec.The GIS shall be 3 phase combined and single bus type. CT ratio for the incomer shall be ***/1+1+1 Aand PT shall be 11000/sqrt3 Volt/110/sqrt 3 Volt. Vacuum Circuit breaker, numerical relays having IEC 61850 protocoland multifunctional metersfor SCADA compatibility as per attached technical specification.All the GIS panels shall be operated and monitored through SCADA.C) Remote Terminal Unit Panel with Ethernet Switch and interposing relay DI/DO as per the mentioned GIS panels list which includes Master Remote Terminal unit, RTU Control Panel & Cabling between RTU and GIS Panel boards. 896 Supply & Erection of 100KVA, 11 kV/0.415 kv Station Transformer alongwith allaccessories as per TS.Energy Efficiency Level-1 897 Supply & Erection of40mm dia 3000mm long GI Pipe (Medium Grade) earth electrodes & other accessories for treated earth erection is including of Excavation and other associated activities as per TS. 898 Supply & Erection of 60x8 mm Galvanized flat for raiser for earthing as per TS 899 Suplly & Erection of 30 KV, 1 Phase, 10KA LA with all accessories as per TS. 900 Supply & Erection of 9 KV, 1 Phase, 10KA LA with all accessories as per TS. 901 Supply & Erection of 3Cx400 sqmm. 33 KV cable (Panel to Transformer- 1 Run) with cable tray. 902 Supply & Erection of 3Cx300 sqmm. 11 KV cable (Panel to Transformer- 2 Run) with cable tray. 903 Supply & Laying of Control Cable of 2 core 2.5 sq. mm copper cable with cable tray and associated items 904 Supply & Laying of Control Cable of 4 core 2.5 sq. mm copper cable with cable tray associated items 905 Supply & Layingof Control Cable of 10 core 2.5 sq. mm copper cable with cable tray associated items 906 Supply & ErectionFire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for controlroom, CO 2 Type of 4.5Kg Capacity4 nos for Control Room, Fire bucketswith Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings 907 Supplyof Synthetic Rubber mats as per IS 15652 in control room 2.5 mm thik 908 Supply and Erection of 33 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 400 sqmm 909 Supply and erection of 11 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 300 sqmm(Incoming) 910 Supply and Erection of 33KV XLPE Cable (3x400 Sq.mm.)outdoor Heat Shrinkable Termination kit boxes mounted with transformer. 911 Supply and Erection of 11KV XLPE Cable (3x300 Sq.mm.)outdoor Heat Shrinkable Termination kit boxes mounted with transformer. 912 Construction of Plinth & Foundation for 10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS 913 Supply & Erectionof Station Lighting System (External) 120 Watt, LEDwith proper illuminationcomplete for switchyard,main gate and sub-station boundry including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. all complte as per applicable TS and approved drawing. (minimum 8 nos on Lighting Poles & 8 nos on structure & control room ) 914 Supply & Erectionof Station Lighting System (internal) with proper illumination complete forcontrol room building, Incharge room, Battery room, Store room, Washroom, Guard room, portico etc.including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc.and Celling, wall Fan & exhast fan (Total 8 nos.) all complte as per applicable TS and approved drawing. 915 Constructionof BoundaryWall (includingsupply of material) with fixing of MS angle & Barbed wire fencing(around Transformer and wherever required) all along the boudary wall includingPlasteringand Distempering(both sides),supplyand fixing of main gate - complete with painting (with double coating of metallic primer and paint)etc.all as per approved drawing &TS (Measurementfor this purpose will include length of the gate along the boundarywall). 916 Civils works(including supply ofmaterial) for 33/1 lkV containerised substation including foundation, including RCC cable trench with precast trench covers for incoming and outgoing cables(Both 33KV & llKV ) and other related works to complete installation, testing, commissioning of substation included. 917 Development of land includes filling of land upto two feet above thr adjoining road, construction of wash room cum toilet with septic and overhead water tanks,drainage system,drinking water supply(Borewell with submersible pump set complete),sewerage system of substation, construction of approch road(5mtr wide) etc. as per approveddrawing or as per instruction of Engineer -in- Charge (including supply of material) 918 Development of land includes filling of land upto two feet above thr adjoining road, construction of wash room cum toilet with septic and overhead water tanks,drainage system,drinking water supply(Borewell with submersible pump set complete),sewerage system of substation, construction of approch road(5mtr wide) etc. as per 919 Constriction (including supply of all material) of RCC cable trench along with pre-cast RCC trench cover, Brick work whenever required all complete as per approved drawing and TS outside the conbol room building - 0.5 Mtrs wide bench. 920 11kV Feeder Double Pole structure on 11kV STP alongwith fitting (as per Annex-9) 921 Supply & Erectionof 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55) 922 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 923 Suplly &Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt. 924 Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt. 925 Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 926 3.96 MVAr With APFC Panel As per TS 927 Supply & Erection of 12.65 kV, 3960 kVAr, 3-Phase, 50 C/shoused in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set 928 Supply &Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank) 929 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank) 930 Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank) 931 Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank) 932 Supply& Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank) 933 Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank) 934 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank) 935 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank) 936 Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank) 937 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(3.96 MVAr HT Capacitor bank) 938 Casting of Civil foundation(3.96 MVAr HT Capacitor bank) 939 Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank) 940 Supply & Erection for New 33 KV Lineon 9 mtr PCC pole with DOG conductor asper technical specifications, scope of works and approved drawings 941 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 942 Eerection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 943 Supply & Erection of 9 m PCC Poles - (PCC Pole as per state practice) 944 Supply & Erection of Stone Pad(300x300x75mm) 945 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 946 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for erection of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 947 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 948 Supply & Erection of 33 KV danger board 949 Supply & Erection of GI Barbed wire 12 SWG 950 Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings 951 Supply & Erection of 33 KV 10 KN Polymer Pin Insulators 952 8 SWG GI Coil 115 turns (1.85 Kg) 953 Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 954 Grouting of complete stay set with0.3 cumt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 955 Supply & Erection of 6 SWG GI wire 956 Supply & Erection of 8 SWG GI wire 957 Supply & Erection of PG Clamp for Dog to Dog conductor 958 Supply & Erection for New 33 KV Lineon 11 mtr steel tubular pole with DOG conductor asper technical specifications, scope of works and approved drawings 959 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 960 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 961 Supply & Erection of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 962 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 963 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for erection of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 964 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 965 Supply & Erection of 33 KV danger board 966 Supply & Erection of GI Barbed wire 12 SWG 967 Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings (B&S Type) 968 Supply & Erection of 33 KV 10 KN Polymer Pin Insulators 969 8 SWG GI Coil 115 turns (1.85 Kg) 970 Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 971 Erection of complete stay set with0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 972 Supply & Erection of 6 SWG GI wire 973 Supply & Erection of 8 SWG GI wire 974 Supply & Erectionof PG Clamp for Dog to Dog conductor 975 Supply & Pinting of silver paint 976 Supply & Painting of red oxidepaint 977 Supply & Erection for New 33 KV Line on 13 mtr steel tubular pole with DOG conductor asper technical specifications, scope of works and approved drawings 978 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 979 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 980 Supply & Erection of 13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) As per TS 981 Excvation & Grouting of 13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 982 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 983 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 984 Supply & Erection of 33 KV danger board 985 Supply & Erection of GI Barbed wire 12 SWG 986 Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings (B&S Type) 987 Supply & Erection of 33 KV 10 KN Polymer Pin Insulators 988 8 SWG GI Coil 115 turns (1.85 Kg) 989 Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 990 Erection of complete stay set with0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 991 Supply & Erection of 6 SWG GI wire 992 Supply & Erection of 8 SWG GI wire 993 Supply & Erection of PG Clamp for Dog to Dog conductor 994 Supply & Painting of silver paint 995 Supply & Paintingof red oxidepaint 996 Supply & Erection of 33 KV Under ground cable as per technical specification, approved drawings and scope of work. 997 Supplyof 3CX300 Sqmm 33 KV XLPE Armored Cable . 998 Digging of trench for laying of Double circuit 33KV 3x300 sq.mm XLPE cable and making of trench for two nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone/Precast slab (PuVVNL 33 KV HT engraved) after laying of cable into the trench including providing and fixing cable route marker. 999 Digging of trench for laying of Single circuit 33KV 3x300 sq.mm XLPE cable and making of trench for two nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone/Precast slab (PuVVNL 33 KV HT engraved) after laying of cable into the trench including providing and fixing cable route marker. 1000 Laying of Singlecircuit of 3x300 Sq. mm 33KV XLPE insulated cable underground in cable trenchesand earth filling of trenches 1001 Laying of 33 KV 3x300 Sqmm. XLPE Cable underground through HDPEPipe at 1050 mm below the ground surface.(by HDD method) for road crossing including providing and fixing cable route marker. 1002 Supplyof 160 mm dia. HDPE pipe.(PE -80 & PN-6) 1003 Laying of 160 mm dia. HDPE pipe by Horizontal drilling by HDD method as per site condition, for underground piping (trenchless) for road crossing. 1004 Supply & Erection ofof Heat Shrinkable Jointing Straight Through Kitfor 33 KV 3x300 sq. mm XLPE Cable 1005 Supply & Erection ofof Heat Shrinkable Jointing Straight Through Kitfor 33 KV 3x300 sq. mm XLPE Cable 1006 Supply & Erectionof G.I. pipe 150mmwith clamp and nut & bolts 1007 Hoisting of cable on double pole with the help of cable clamp with N&B of suitable size 1008 Supply & Erection of 33 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 1009 Supply & Erection, testing & commissioning of33 kV LINEFORUNDER GROUND RAILWAY CROSSING (300 Mtr) BY 2 Nos (INCLUDING ONE SPARE)3Cx300 Sqmm XLPE Armoured Cable USING 150MM DIA GI PIPES (grade A for underground laying and grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS,LUGS, 4 Nos GI 3-Meters LONG pipe, EARTHING, 8 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS, JUMPERING , AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 1010 Supply & Erection of 11 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 1011 Supply & Erection, testing & commissioning of 33 kV LINEFORUNDER GROUND Highway CROSSING (200 Mtr) BY 2 Nos (INCLUDING ONE SPARE)3Cx300 Sqmm XLPE Armoured Cable USING 150MM DIA GI PIPES (grade A for underground laying and grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS,LUGS, 4 Nos GI 3-Meters LONG pipe, EARTHING, 8 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS, JUMPERING , AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 1012 Supply & Erection For Construction of new 11 KV line on 8.5 mtr PCC pole with weasel conductor asper technical specifications, scope of works and approved drawings 1013 Supplyof 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel 1014 Erection of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel 1015 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1016 Supply & Erection of Stone Pad(300x300x75mm) 1017 Erection of 8.5 m/180 Kgs PCC Poles withBase stone pad including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications(state practices of PCC pole and base plate/stone to be used) 1018 Supply & Erection of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1019 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1020 Supply & Erection of 11 KV danger board 1021 Supply & Erection of GI Barbed wire 12 SWG 1022 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1023 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1024 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1025 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1026 StayGrouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1027 Supply & Erection of 6 SWG GI wire 1028 Supply & Erection of 8 SWG GI wire 1029 Supply & Erection of PG Clamp for Weasel to Weasel conductor 1030 Supply & Erection For Construction of new 11 KV line on 11mtr STP pole with Rabbit conductor asper technical specifications, scope of works and approved drawings 1031 Supplyof 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit 1032 Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit 1033 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1034 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1035 Supply & Erection forPre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1036 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1037 Supply & Erection of 11 KV danger board 1038 Supply & Erection of GI Barbed wire 12 SWG 1039 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1040 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1041 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1042 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1043 Stay Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1044 Supply & Erection of 6 SWG GI wire 1045 Supply & Erection of 8 SWG GI wire 1046 Supply & Erection of PG Clamp for Rabbit to Rabbit conductor 1047 Supply & Painting of silver paint 1048 Supply & Painting of red oxidepaint 1049 Supply & Erection For Construction of new 11 KV line on 11mtr STP pole with Dog conductor asper technical specifications, scope of works and approved drawings 1050 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 1051 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 1052 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1053 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1054 Supply & Erection of New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1055 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1056 Supply & Erection of 11 KV danger board 1057 Supply & Erection of GI Barbed wire 12 SWG 1058 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings (B&S Type) 1059 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with Nut & Bolt. 1060 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1061 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1062 Stay Grouthing 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1063 Supply & Erection of 6 SWG GI wire 1064 Supply & Erection of 8 SWG GI wire 1065 Supply & Erection of PG Clamp for Dog to Dog conductor 1066 Supply & Paintingof silver paint 1067 Supply & Painting of red oxidepaint 1068 Supply & Erection For Construction of new 11 KV line on 8.5mtr PCC pole with Rabbit conductor asper technical specifications, scope of works and approved drawings 1069 Supplyof 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit 1070 Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit 1071 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1072 Supply & Erection of Stone Pad(300x300x75mm) 1073 Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1074 Supply & Erectionof New3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1075 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1076 Supply & Erection of 11 KV danger board 1077 Supply & Erection of GI Barbed wire 12 SWG 1078 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1079 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with Nut & Bolt. 1080 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1081 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1082 Stay Grouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1083 Supply & Erection of 6 SWG GI wire 1084 Supply & Erection of 8 SWG GI wire 1085 Supply & Erection of PG Clamp for Rabbit to Rabbit conductor 1086 Supply & Erection of 11 KV Lineunderground 3*185 XLPE Cableensuring statutory clearances as required as per technical specification, approved drawings and scope of work 1087 Supply of 3Cx185 Sqmm 11 KV XLPE Armored Cable 1088 Digging of trench for laying of double circuit 11KV 3x185 sq.mm XLPE cable and making of trench for two nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone slab /Precast slab (PuVVNL 11 KV HT engraved) after laying of cable into the trench including providing and fixing cable route marker. 1089 Digging of trench for laying of Single circuit 11KV 3x185 sq.mm XLPE cable and making of trench for one nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone slab after laying of cable into the trench. 1090 Laying of single circuit of 3x185 Sq. mm 11KV XLPE insulated cable underground in cable trenchesand earth filling of trenches 1091 Laying of 11 KV 3Cx185 sq.mm XLPE Cable underground through HDPEPipe at 950 mm below the ground surface. (by HDD method) including providing and fixing cable route marker. 1092 Supply& Erection of 110 mm dia. HDPE pipe . 1093 Supply & Erection of Heat Shrinkable Jointing Kit Straight throughfor 11 KV 3x185 sq. mm XLPE Cable 1094 Supply & Erection of Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable 1095 Supply & Erectionof G.I. pipe 110 mm diawithclamps, Nut and Bolts. 1096 Hoisting of cable on double pole with the help of cable clamp with N&B of suitable size 1097 Supply & Erection For new 11 KV line on 11 mtr STP with insulated covered (50 sq mm) conductorasper technical specifications, scope of works and approved drawings 1098 SupplyOf Insulated ACS Covered Conductor Size equivalent to Rabbit conductor. 1099 Erection of Insulated ACS Covered Conductor Size equivalent to Rabbit conductor. 1100 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1101 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1102 Supply & Erection of New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1103 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1104 Supply & Erection of 11 KV danger board 1105 Supply & Erection of GI Barbed wire 12 SWG 1106 Supply & Erection Tension clamp/Dead Clamp/Anchoring Clamp with Piercing Connectors suitable for MVCC. 1107 Supply& Erectionof IPC for CC to CC Connection suitable for MVCC 1108 Supply & Erection of IPC/Connector for Bare to CC Connection suitable for MVCC 1109 Supply & Erection of Suspension/Insulated Ties 1110 Supply & Erection of Mid Span Jointing Kit 1111 Supply & Erection ofIPC with Aluminium bail for earthing 1112 Supply & Erectionof Termination Kits 1113 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1114 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1115 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1116 Supply & Erection of 6 SWG GI wire 1117 Supply & Erection of 8 SWG GI wire 1118 Supply & Paintingof silver paint 1119 Supply & Painting of red oxidepaint 1120 Supply & Erection For new 11 KV line on 3x70 sqmm XLPE cable asper technical specifications, scope of works and approved drawings 1121 Supplyof 11 Kv Line on 3x70 sqmm XLPE Cable 1122 Erection of 11 Kv Line on 3x70 sqmm XLPE Cable 1123 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1124 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1125 Supply & Erection of new 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1126 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1127 Supply & Erection of 11 KV danger board 1128 Supply & Erection of GI Barbed wire 12 SWG 1129 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1130 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1131 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1132 Supply & Erection of 6 SWG GI wire 1133 Supply & Erection of 8 SWG GI wire 1134 Supply & Erection of cable Jointing kit for 11 kvLine 70 sqmm 1135 Supply & Painting of silver paint 1136 Supply & Painting of red oxidepaint 1137 Supply & Erection of 11 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 1138 Supply & Erection , testing & commissioningfor 11 KV lineunder ground Railway crossing with 2 nos (Including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) using 150mm dia GI pipes (grade A for underground laying and grade B for pole support), Outdoor heat shrinkable cable jointing kit, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES,CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 1139 Supply & Erection of 11 LV Line underground Highway crossing ensuring statutory clearancesas required as per technical specification, approved drawings and scope of work 1140 Supply & Erection , testing & commissioning of 11 KV LINEFORUNDER GROUND Highway CROSSING BY 2 Nos (INCLUDING ONE SPARE) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) USING 160 mm HDPE pipe at road crossing and 150MM DIA GI PIPES (gradeB for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES, 7/20 GI wire, CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 1141 New Distribution Transformer25 KVA 11/433 KV - Supply 1142 supply & Erectionof 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1143 Concreting of supports with Grounting of 0.5 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1144 Supply & Erectionof new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel,Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete asper TS & approved drawings. 1145 Supply & Erectionof hot dip galvanized MS Nuts, Bolts with Washers as per TS 1146 Supply& Erection of 11 KV 5 KN Polymer Pin Insulators 1147 Supply& Erection of 11 KV45 KN polymer Disc insulatoras per TS. 1148 Supply& Erectionof suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductoras per TS. 1149 Supply& Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1150 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1151 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1152 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1153 Supply& Erection of 6 SWG GI wire for earthing as per TS 1154 Supply &Erectionof Barbed GI wire 12 SWG 1155 Supply& Erection of PG Clamp suitable for ACSRRabbit conductor as per TS 1156 Supply & Erectionof 11 KV danger board 1157 Supply& Erection of 11 KV, 3-Pole, 3-Ph, 400A, TPMO as per TS 1158 SupplyErection of 11 KV, 3-Ph, 400A, DO Fuse as per TS 1159 Supply of 3-Phase, 11/0.4 kV, 25KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS ,Energy Efficiency Level-1 1160 Supply & Erection of LT Distribution box with suitable rating MCCB for incomer & MCCBfor two no outgoing feeder suitable for 25 kVA,Distribution Transformer alongwithsuitable for pole mounting as per TS 1161 Supply& Erectionof 9 kV, 5 KA porcelain housing Lightning Arrestorwith Disconnector for DTas per TS. (3 nos=1 set) 1162 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1163 Supply& Erection of Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1164 Supply& Erection of 1-Core 70 mm2, Al. LT XLPE Cable as per TS 1165 New Distribution Transformer63 KVA 11/433 KV - Supply 1166 supply& Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1167 Concreting of supports with Grounting f 0.5 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1168 Supply& Erectionof new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel,Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete asper TS & approved drawings. 1169 Supply& Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1170 Supply& Erection of 11 KV 5 KN Polymer Pin Insulators 1171 Supply& Erection of 11 KV45 KN polymer Disc insulatoras per TS. 1172 Supply& Erection of suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductoras per TS. 1173 Supply& Erectoin of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1174 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1175 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1176 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1177 Supply & Erectoin of 6 SWG GI wire for earthing as per TS 1178 Supply& Erection of Barbed GI wire 12 SWG 1179 Supply& Erection of PG Clamp suitable for ACSR Weaselconductor as per TS 1180 Supply & Erection of 11 KV danger board 1181 Supply& Erection of 11 KV, 3-Pole, 3-Ph, 400A, A B Switch as per TS 1182 Supply & Erection of 11 KV, 3-Ph, 400A, DO Fuse as per TS 1183 Supply& Erection of 3-Phase, 11/0.4 kV, 63 KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS ,Energy Efficiency Level-1 1184 Supply& Erection of of LT Distribution box with suitable rating MCCB for incomer & MCCBfor two no outgoing feeder suitable for 63 kVA,Dist1ibution Transformer alongwith suitable for pole mounting as per TS 1185 Supply& Erection of of 9 kV, 5 KA porcelain housing Lightning Arrestorwith Disconnector for DTas per TS. (3 nos=1 set) 1186 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1187 Supply & Erectionof Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1188 Supply& Erection of 1-Core 240 mm2, Al. LT XLPE Cable as per TS 1189 New Distribution Transformer 100 KVA 11/433 KV - Supply 1190 supply& Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1191 Concreting of supports with Grounting f 0.5 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1192 Supply& Erection of new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel,Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete asper TS & approved drawings. 1193 Supply& Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1194 Supply& Erection of 11 KV 5 KN Polymer Pin Insulators 1195 Supply& Erection of 11 KV45 KN polymer Disc insulatoras per TS. 1196 Supply& Erection of suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductoras per TS. 1197 Supply& Erectoin of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1198 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1199 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1200 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1201 Supply & Erectoin of 6 SWG GI wire for earthing as per TS 1202 Supply& Erection of Barbed GI wire 12 SWG 1203 Supply& Erection of PG Clamp suitable for ACSR Weaselconductor as per TS 1204 Supply & Erection of 11 KV danger board 1205 Supply& Erectionof 11 KV, 3-Pole, 3-Ph, 400A, A B Switch as per TS 1206 Supply & Erection of 11 KV, 3-Ph, 400A, DO Fuse as per TS 1207 Supply& Erection of 3-Phase, 11/0.4 kV, 100 KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS ,Energy Efficiency Level-1 1208 Supply & Erectionof LT Distribution box with suitable rating MCCB for incomer & MCCBfor two no outgoing feeder suitable for 100 kVA,Dist1ibution Transformer alongwithsuitable for pole mounting as per TS 1209 Supply &Erectionof 9 kV, 5 KA porcelain housing Lightning Arrestorwith Disconnector for DTas per TS. (3 nos=1 set) 1210 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm . 1211 Supply & Erection Earthing Arrangement ofchemical pipe size of 40x3000 mm. a etc. 1212 Supply& Erection of 1-Core 240 mm2, Al. LT XLPE Cable as per TS 1213 New Distribution Transformer 250 KVA 11/433 KV - Supply 1214 Supply& Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1215 Concreting of supports with Grounting f 0.5 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1216 Supply& Erectionof new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel,Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete asper TS & approved drawings. 1217 Supply& Erectionof hot dip galvanized MS Nuts, Bolts with Washers as per TS 1218 Supply& Erection of 11 KV 5 KN Polymer Pin Insulators 1219 Supply& Erection of 11 KV45 KN polymer Disc insulatoras per TS. 1220 Supply& Erection of suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductoras per TS. 1221 Supply& Erectoin of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1222 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1223 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1224 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1225 Supply & Erectoin of 6 SWG GI wire for earthing as per TS 1226 Supply& Erection of Barbed GI wire 12 SWG 1227 Supply& Erection of PG Clamp suitable for ACSR Weaselconductor as per TS 1228 Supply & Erection of 11 KV danger board 1229 Supply& Erectionof 11 KV, 3-Pole, 3-Ph, 400A, A B Switch as per TS 1230 Supply & Erection of 11 KV, 3-Ph, 400A, DO Fuse as per TS 1231 Supply& Erection of 3-Phase, 11/0.4 kV, 250KVA, Self Protected, Copperwinding & CRGO core Distribution Transformer as per TS, Energy Efficiency Level-1 1232 Supply & Erectionof LT Distribution box with suitable rating MCCB for incomer & MCCBfor two no outgoing feeder suitable for 250 kVA,Dist1ibution Transformer alongwithsuitable for pole mounting as per TS 1233 Supply & Erectionof 9 kV, 5 KA porcelain housing Lightning Arrestorwith Disconnector for DTas per TS. (3 nos=1 set) 1234 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1235 Supply & Erectionof Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1236 Supply& Erection of 1-Core 240 mm2, Al. LT XLPE Cable as per TS 1237 Augmentation of 10 kva&16 kva to 25kvaDistribution transformer 1238 Supply & Erection of11/0.433 kV 25kVA Distribution Transformer as per TS.Energy Efficiency Level-1 1239 Supply & Erection ofLT PVC Cable 3.5x70Sq.mm 1240 Supply& Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1241 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1242 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1243 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1244 Supply & Erection of 6 SWG GI wire for earthing as per TS 1245 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1246 Supply & Erection Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1247 Replacment & Transpotation Charge of Existing Distribution Transformer 1248 Augmentation of25 Kva to 63kvaDistribution transformer 1249 Supply & Erection 11/0.433 kV 63kVA Distribution Transformeras per TS. Energy Efficiency Level-1 1250 Supply & Erection LT PVC Cable 3.5x70Sq.mm 1251 Supply& Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1252 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1253 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1254 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1255 Supply& Erection of 6 SWG GI wire for earthing as per TS 1256 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1257 Supply & Erection of Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1258 Replacment & Transpotation Charge of Existing Distribution Transformer 1259 Augmentation of 63 kva to 100 kvaDistribution transformer 1260 Supply & Erection of11/0.433 kV 100kVA Distribution Transformeras per TS. Energy Efficiency Level-1 1261 Supply & Erectionof LT PVC Cable 3.5x150Sq.mm 1262 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1263 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1264 Supply& Erectionof stay guy insulator (1 Nos.),as per TS 1265 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1266 Supply& Erection of 6 SWG GI wire for earthing as per TS 1267 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1268 Supply & Erection of Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1269 Replacment & Transpotation Charge of Existing Distribution Transformer 1270 Augmentation of 100 kva & 160 kva to 250 kvaDistribution transformer 1271 Supply & Erection of 11/0.4 KV Distribution Transformer 250 KVA 3 phaseDTR(Copper Winding), Energy Efficiency Level-1 1272 Supply & ErectionofLT PVC cable AI 3.5x400 sq mm 1273 Supply& Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1274 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1275 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1276 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1277 Supply & Erectionof 6 SWG GI wire for earthing as per TS 1278 Supply & ErectionofEarthing for pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1279 Supply & Erection ofEarthingfor Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1280 Replacment & Transpotation Charge of Existing Distribution Transformer 1281 Augmentation of 250 kva to 400 kvaDistribution transformer 1282 Supply & Erectionof 11/0.4 KV Distribution Transformer 400 KVA 3 phaseDTR(Copper Winding, Energy Efficiency Level-1 1283 Supply & Erection ofLT PVC XLPEcable AI 1x400 sq mm 1284 Supply & Erection of LT PVCXLPE cable AI 1x240 sq mm 1285 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1286 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1287 Supply & Erectionof stay guy insulator (1 Nos.),as per TS 1288 Supply & Erectionof 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1289 Supply& Erection of 6 SWG GI wire for earthing as per TS 1290 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1291 Supply & ErectionofEarthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1292 Supply & Erection of Al Lug long barrel, off size (LS) 1293 Replacment & Transpotation Charge of Existing Distribution Transformer 1294 Supply & Erection of Trolly Mounted DT- of 400KVA asper technical specifications, scope of works and approved drawings 1295 Supply & Erection of 11/0.415 kV 400 KVA Distribution Transformer Copper Winding. Energy Efficiency Level-1 1296 Supply & Erection of Fabricated Trolley With 4 Tyre wheels to house Transformer with all fixing Arrangement along with fencing and locking mechanism. 1297 Supply & Erection of 3x50 mm² 11KV class XLPE Cable. 1298 Supply & Erection of Heat shrinkable Termination kits suitable for 3x50 mm²Xlpe Cable (out door) including bushing cap. 1299 Supply & Erection of 400 Sq.mm., LT single core `XLPE insulatedun-armoured aluminium conductor cable 1300 Supply & Erection of Protection of DT asper technical specifications, scope of works and approved drawings 1301 Supply & Erection ofAB switch suitable for Distribution Transformer 100 KVA and above 1302 Supply & Erection of DO Fuse set suitable for Distribution Transformer 100 KVA and above 1303 Supply & Erection of LT ACB suitable for Distribution transformers having capacity 250 KVA and above Ap per TS 1304 Supply & Erection of LT Distribution box suitablefor Distribution Transformer upto 250 KVAAs per TS 1305 Supply & Erection of LT Distribution box suitable for Distribution Transformer 400 KVA and above As per TS 1306 Supply & Erection of DT Cable with Lugs & Clamp asper technical specifications, scope of works and approved drawings 1307 Supply & Erection of LT XLPE Insulated Cable 1CX240 Sqmm 1308 Supply & Erection LT XLPE Insulated Cable 1CX400 Sqmm 1309 Supply & ErectionLTXLPE Insulated Cable 1CX630 Sqmm 1310 New LT line on 8.5 mtr PCC pole with AB cable ( (1x16+1x25+1x16) 1311 Supplyof LT Aerial bunchedXLPE cable 1X16 sqmm (Ph) + 1x25 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1312 Eection of LT Aerial bunchedXLPE cable 1X16 sqmm (Ph) + 1x25 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1313 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1314 Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1315 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1316 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1317 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1318 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1319 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1320 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1321 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1322 Supply & Erection of 8 SWG GI wire for earthing as per TS 1323 Supply & Erection of Three phase SMC Distribution box with clamps 1324 Supply & Erectionof 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1325 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1326 Supply of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1327 Supply & Erection of 35 Sqmm PG Clamps as per TS 1328 Supply & Erection of LT Insulation piercing connector 16 -16 sqmm size for phase connection as per TS & approve drawing 1329 Supply & Erection of LT Insulation piercing connector 16-25 sqmm size for phase connection as per TS & approve drawing 1330 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1331 New Lt8.5 Mtr PCCLT Ckt. with AB Cable (3x50+1x35+1x16) 1332 Supplyof LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1333 Erection of LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1334 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1335 Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1336 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1337 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1338 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1339 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1340 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1341 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1342 Supply & Erectionof 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1343 Supply & Erection of 8 SWG GI wire for earthing as per TS 1344 Supply & Erectionof Three phase SMC Distribution box with clamps 1345 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1346 Supply & Erectionof Suspension clamp forLT Aerial Bunched Cable as per TS 1347 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1348 Supply & Erectionof 35 Sqmm PG Clamps as per TS 1349 Supply & Erection of LT Insulation piercing connector 50 -50 sqmm size for phase connection as per TS & approve drawing 1350 Supply & Erection of LT Insulation piercing connector 50-35 sqmm size for phase connection as per TS & approve drawing 1351 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1352 LT line on 8.5 mtr PCC pole with AB cable (3x95+1x70+1x16) 1353 Supplyof LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1354 Erection of LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1355 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1356 Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1357 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1358 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1359 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1360 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1361 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1362 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1363 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1364 Supply & Erection of 8 SWG GI wire for earthing as per TS 1365 Supply & Erection of Three phase SMC Distribution box with clamps 1366 Supply & Erectionof 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1367 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1368 Supply& Erection ofTension /dead end clamps for LT Aerial Bunched Cable as per TS 1369 Supply & Erection of 35 Sqmm PG Clamps as per TS 1370 Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing 1371 Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing 1372 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1373 LT line with 11 mtr steel tubular pole with AB cable (3x120+1x95+1x16) 1374 Supplyof LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1375 Erection of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1376 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1377 Grouting of11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1378 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1379 Supply & Erectionof hot dip galvanized MS Nuts, Bolts with Washers as per TS 1380 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1381 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1382 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1383 Supply & Erectionof stay guy insulator (1 Nos.),as per TS 1384 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1385 Supply & Erection of 8 SWG GI wire for earthing as per TS 1386 Supply & Erection of Three phase SMC Distribution box with clamps 1387 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1388 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1389 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1390 Supply & Erection of 35 Sqmm PG Clamps as per TS 1391 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1392 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1393 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1394 LT line with 11 mtr steel tubular pole with AB cable (3x150+1x120+1x16) 1395 Supplyof LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1396 Erection of LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1397 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1398 Gruoting Of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1399 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1400 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1401 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1402 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1403 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1404 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1405 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1406 Supply & Erection of 8 SWG GI wire for earthing as per TS 1407 Supply & Erection of Three phase SMC Distribution box with clamps 1408 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1409 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1410 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1411 Supply & Erection of 35 Sqmm PG Clamps as per TS 1412 Supply & Erection of LT Insulation piercing connector 150 -150 sqmm size for phase connection as per TS & approve drawing 1413 Supply & Erection of LT Insulation piercing connector 150-35 sqmm size for phase connection as per TS & approve drawing 1414 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1415 Strengthening of LT infrastructure by removal of bans and balli in identified areas-Schedule for regularisation of Bas Balli cable for under Varanasi -1as per TS & Approved Drawings. 1416 Supply& Erectionof PCC Pole 8.5 mtr long 1417 Concreting of supports with Grounting of0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 mtr PCC pole Pole of .As per TS. 1418 Supply& Erectionof stone pad (300x300x75mm) 1419 Supply& Erection of STP 9 mtr SP-33 (410 SP 33) 1420 Concreting of supports with Grounting of 0.3 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9 mtr stp pole Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1421 Supply& erectionof Stay set 16x1800 sq mm (including stay rod , turn buckle,I bolt and anchor plate with Guy insulator) 1422 Supply& Erection ofGI Earthing rod (20x2500)mm 1423 Supply& Erectionof Stay wire 7/10 SWG 1424 Supply of & Erection of G.I. wire 5 mm 6 swg 1425 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1426 Supplyof LT A B Cable Size (3x50+1x35+1x16) sq mmwith Bare Massenger ( Insulated Street Lighting ) 1427 Erection of LT A B Cable Size (3x50+1x35+1x16) sq mmwith Bare Massenger( Insulated Street Lighting ) 1428 Supplyof LT A B Cable Size (3x95+1x70+1x16) sq mm with Bare Massenger( Insulated Street Lighting ) 1429 Erectionof LT A B Cable Size (3x95+1x70+1x16) sq mm with Bare Massenger( Insulated Street Lighting ) 1430 Supply of & Erectionof Suspension clamp with eye hook 1431 Supply of & Erection of Dead end clamp insulated with I hook 1432 Supply of & Erection ofHDG pole Clamp for I-Hook with N&B 1433 Supply of & Erection ofLT Insulation piercing connector 95-35 sqmm / 50-35 sqmm size 1434 Supply of & Erectionof Three phase LT SMC Box with clamp 1435 Supply of & Erection ofPG clamp for Neutral 1436 Supplyof L T XLPE unarmoured Cable of size 4C x 35 sq mm 1437 Erection of L T XLPE unarmoured Cable of size 4C x 35 sq mm 1438 Supply of & Erection of pre insulated compression connector of size 95/50 Sqmm 1439 Supply of & Erection ofStay clamp with N&B 1440 Extra Circuits 8.5 Mtr PCCLT Ckt. with AB Cable (3x50+1x35+1x16) 1441 Supplyof LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1442 Erection of LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1443 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1444 Concreting of supports with Grounting of 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1445 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1446 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1447 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1448 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1449 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1450 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1451 Supply & Erectionof 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1452 Supply & Erection of 8 SWG GI wire for earthing as per TS 1453 Supply & Erectionof Three phase SMC Distribution box with clamps 1454 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1455 Supply & Erectionof Suspension clamp forLT Aerial Bunched Cable as per TS 1456 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1457 Supply & Erectionof 35 Sqmm PG Clamps as per TS 1458 Supply & Erection of LT Insulation piercing connector 50 -50 sqmm size for phase connection as per TS & approve drawing 1459 Supply & Erection of LT Insulation piercing connector 50-35 sqmm size for phase connection as per TS & approve drawing 1460 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1461 Extra Circuits 8.5 Mtr PCCLT Ckt. with AB Cable (3x95+1x70+1x16) 1462 Supplyof LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1463 Erection of LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1464 Supply& Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1465 Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1466 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1467 Supply& Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1468 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1469 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1470 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1471 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1472 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1473 Supply & Erectionof 8 SWG GI wire for earthing as per TS 1474 Supply & Erection of Three phase SMC Distribution box with clamps 1475 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1476 Supply & Erectionof Suspension clamp forLT Aerial Bunched Cable as per TS 1477 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1478 Supply & Erection of 35 Sqmm PG Clamps as per TS 1479 Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing 1480 Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing 1481 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1482 Extra Circuits 9mtr STP PoleLT Ckt. with AB Cable (3x95+1x70+1x16) 1483 Supplyof LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1484 Erection of LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1485 supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980) 1486 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 1487 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1488 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1489 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1490 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1491 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1492 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1493 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1494 Supply & Erection of 8 SWG GI wire for earthing as per TS 1495 Supply & Erectionof Three phase SMC Distribution box with clamps 1496 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1497 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1498 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1499 Supply & Erection of 35 Sqmm PG Clamps as per TS 1500 Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing 1501 Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing 1502 Supply & Erectionof LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1503 Extra Circuit LT line with 8.5 Mtr/180 kgs PCC Poles with AB cable (3x120+1x95+1x16) 1504 Supply of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1505 Erection of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1506 Supply & Erectionof 8.5 Mtr/180 kgs PCC Poles as per TS 1507 Concreting of supports with Grountingof0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1508 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1509 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1510 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1511 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1512 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1513 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1514 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1515 Supply & Erection of 8 SWG GI wire for earthing as per TS 1516 Supply & Erection of Three phase SMC Distribution box with clamps 1517 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1518 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1519 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1520 Supply & Erection of 35 Sqmm PG Clamps as per TS 1521 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1522 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1523 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1524 Extra Circuit LT line with 9 mtr steel tubular pole with AB cable (3x120+1x95+1x16) 1525 Supply of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1526 Erectionof LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1527 Supply & Erectionof 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980) 1528 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 1529 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1530 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1531 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1532 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1533 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1534 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1535 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1536 Supply & Erection of 8 SWG GI wire for earthing as per TS 1537 Supply & Erection of Three phase SMC Distribution box with clamps 1538 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1539 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1540 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1541 Supply & Erection of 35 Sqmm PG Clamps as per TS 1542 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1543 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1544 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1545 Extra Circuit LT line with 11 mtr steel tubular pole with AB cable (3x120+1x95+1x16) 1546 Supplyof LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1547 Erection of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1548 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1549 Gruoting Of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1550 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1551 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1552 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1553 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1554 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1555 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1556 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1557 Supply & Erection of 8 SWG GI wire for earthing as per TS 1558 Supply & Erection of Three phase SMC Distribution box with clamps 1559 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1560 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1561 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1562 Supply & Erection of 35 Sqmm PG Clamps as per TS 1563 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1564 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1565 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1566 Extra Circuit LT line with 11 mtr steel tubular pole with AB cable (3x150+1120+1x16) 1567 Supply of LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1568 Erection of LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1569 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1570 Concreting of supports with Grountingof0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1571 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1572 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1573 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1574 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1575 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1576 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1577 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1578 Supply & Erection of 8 SWG GI wire for earthing as per TS 1579 Supply & Erection of Three phase SMC Distribution box with clamps 1580 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1581 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1582 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1583 Supply & Erection of 35 Sqmm PG Clamps as per TS 1584 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1585 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1586 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1587 Extra CircuitLT line with 9 mtr steel tubular pole with AB cable (3x150+1x120+1x16) 1588 Supplyof LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1589 Erection of LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1590 Supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980) 1591 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 1592 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1593 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1594 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1595 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1596 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1597 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1598 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1599 Supply & Erection of 8 SWG GI wire for earthing as per TS 1600 Supply & Erection of Three phase SMC Distribution box with clamps 1601 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1602 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1603 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1604 Supply & Erection of 35 Sqmm PG Clamps as per TS 1605 Supply & Erection of LT Insulation piercing connector 150 -150 sqmm size for phase connection as per TS & approve drawing 1606 Supply & Erection of LT Insulation piercing connector 150-35 sqmm size for phase connection as per TS & approve drawing 1607 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1608 Extra Circuit LT line with 11 mtr steel tubular pole with AB cable (3x150+1x120+1x16) 1609 Supplyof LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1610 Erection of LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1611 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1612 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1613 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1614 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1615 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1616 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1617 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1618 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1619 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1620 Supply & Erection of 8 SWG GI wire for earthing as per TS 1621 Supply & Erection of Three phase SMC Distribution box with clamps 1622 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1623 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1624 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1625 Supply & Erection of 35 Sqmm PG Clamps as per TS 1626 Supply & Erection of LT Insulation piercing connector 150 -150 sqmm size for phase connection as per TS & approve drawing 1627 Supply & Erection of LT Insulation piercing connector 150-35 sqmm size for phase connection as per TS & approve drawing 1628 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1629 Augmentation of LT line with 8.5 Mtr PCC Pole pole with AB cable (3x120+1x95+1x16) 1630 Supplyof LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1631 Erection of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1632 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1633 Concreting of supports with Grountingof0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1634 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1635 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1636 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1637 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1638 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1639 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1640 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1641 Supply & Erection of 8 SWG GI wire for earthing as per TS 1642 Supply & Erection of Three phase SMC Distribution box with clamps 1643 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1644 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1645 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1646 Supply & Erection of 35 Sqmm PG Clamps as per TS 1647 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1648 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1649 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1650 Augmentation of LT line with 9 Mtr STP Pole pole with AB cable (3x120+1x95+1x16) 1651 Supplyof LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1652 Erection of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1653 Supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980) 1654 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 1655 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1656 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1657 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1658 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1659 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1660 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1661 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1662 Supply & Erection of 8 SWG GI wire for earthing as per TS 1663 Supply & Erection of Three phase SMC Distribution box with clamps 1664 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1665 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1666 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1667 Supply & Erection of 35 Sqmm PG Clamps as per TS 1668 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1669 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1670 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1671 Augmentation of LT line on 8.5 mtr PCC pole with AB cable (3x95+1x70+1x16) 1672 Supplyof LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1673 Erection of LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1674 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1675 Concreting of supports with Grountingof0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1676 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1677 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1678 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1679 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1680 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1681 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1682 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1683 Supply & Erection of 8 SWG GI wire for earthing as per TS 1684 Supply & Erection of Three phase SMC Distribution box with clamps 1685 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1686 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1687 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1688 Supply & Erection of 35 Sqmm PG Clamps as per TS 1689 Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing 1690 Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing 1691 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1692 Augmentation of LT line on 9 Mtr STP pole with AB cable (3x95+1x70+1x16) 1693 Supplyof LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1694 Erection of LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1695 Supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980) 1696 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 1697 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1698 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1699 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1700 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1701 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1702 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1703 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1704 Supply & Erection of 8 SWG GI wire for earthing as per TS 1705 Supply & Erection of Three phase SMC Distribution box with clamps 1706 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1707 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1708 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1709 Supply & Erection of 35 Sqmm PG Clamps as per TS 1710 Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing 1711 Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing 1712 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1713 Supply & Erection of Feeder Bifurcation ( 33KV line on 9 mtr PCC pole(Dog conductor)) as per approved drawings, technical specifications and scope of work 1714 Supply of 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1715 Erection of6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1716 Supply & Erection 9m/400 kgs PCC Poles (PCC pole as per state practice) 1717 Supply & Erection of Stone Pad 300x300x75 MM 1718 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr STP Pole of depth1.5 meter .As per TS. 1719 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1720 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1721 Supply & Erection of Barbed wire 1722 Supply & Erection of Danger Board 1723 Supply &Erection of Number Plate 1724 Supply& Erection of Stay Set ( Galvanised) GI stay rod 20x1800 mm, stay wire 7/8 SWG GI wire, 50x8 mm stay clamp, stay insulator (2 nos.), anchor plate (300x300x8), nut bolts, 2 nos. turn buckles, 1.8 m long 20 mm dia. Solid GI Stay Rod, 7/4.0mm dia. GI stranded wire 1725 Groutingof complete stay set with0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1726 Supply & Erection 33 KV polymer Disc insulator 70 KNB&S along with suitable hardware fittings 1727 Supplt & Erection of 33 KV polymer Pin insulators with GI Pin & nuts 1728 Supply & Erection of GI earthing Spike earthing 20x2500 mm solid rod & 6 SWG earthwire with nut and bolt 1729 Supply & Erection of 6 SWGGI wire, 1730 Supply & Eection of 8 SWG GI wire 1731 Supply & Erection of Feeder Bifurcation (33KV line on 11 mtr steel tubularpole(Dog conductor)) as per approved drawings, technical specifications and scope of work 1732 Supplyof6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1733 Erectionof 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1734 Supply & Erection of 11 m long steel tubular poles with welded steel base plate of designation 410 SP 55 (As per IS: 2713 , pt. I,II,III 1980) 1735 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1736 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1737 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1738 Supply & Erection of Danger Board 1739 Supply & Erection ofbarbed wire 1740 Supply & Erection of Number Plate 1741 Supply & Erection of Stay Set ( Galvanised) GI stay rod 20x1800 mm, stay wire 7/8 SWG GI wire, 50x8 mm stay clamp, stay insulator (2 nos.), anchor plate (300x300x8), nut bolts, 2 nos. turn buckles, 1.8 m long 20 mm dia. Solid GI Stay Rod, 7/4.0mm dia. GI stranded wire 1742 Erection of complete stay set with0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1743 Supply & Erection of 33 KV polymer Disc insulator 70 KNB&S along with suitable hardware fittings 1744 Supply & Erection of 33 KV polymer Pin insulators with GI Pin & nuts 1745 Supply & Erection of GI earthing Spike earthing 20x2500 mm solid rod & 6 SWG earthwire with nut and bolt 1746 Supply & Erection of 6 SWG Wire 1747 Supply & Erection of 8 SWG GI wire, 1748 Supply & Paintingof silver paint 1749 Supply & painting of red oxidepaint 1750 Supply & Erection of Feeder Bifurcation (33KV Line on 13 mtr steel tubularpole Dog conductor) as per approved drawings, technical specifications and scope of work 1751 Supplyof 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1752 Erection of 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1753 Supply & Erection of 13 m longSTP SP72 1754 Supply & Erection of Stone Pad 300x300x75 MM 1755 Concreting of poles as per specification 1756 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1757 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1758 Supply & Erection of Danger Board 1759 Supply & Erection of Barbed wire 1760 Supply & Erection of Number Plate 1761 Supply & Erection of Stay Set ( Galvanised) GI stay rod 20x1800 mm, stay wire 7/8 SWG GI wire, 50x8 mm stay clamp, stay insulator (2 nos.), anchor plate (300x300x8), nut bolts, 2 nos. turn buckles, 1.8 m long 20 mm dia. Solid GI Stay Rod, 7/4.0mm dia. GI stranded wire 1762 Groutingof stay set with0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1763 Supply & Erection of 33 KV polymer Disc insulator 70 KNB&S along with suitable hardware fittings 1764 Supply & Erection of 33 KV polymer Pin insulators with GI Pin & nuts 1765 Supply & Erection of GI earthing Spike earthing 20x2500 mm solid rod & 6 SWG earthwire with nut and bolt 1766 Supply & Erection of 6 SWG GI wire, 1767 Supply & Erection of8 SWG GI wire, 1768 Supply & Painting of silver paint 1769 Supply & Painting of red oxidepaint 1770 Supply & Erection of 33 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 1771 Supply & Erection, testing & commissioning of33 kV LINEFORUNDER GROUND RAILWAY CROSSING (300 Mtr) BY 2 Nos (INCLUDING ONE SPARE)3Cx300 Sqmm XLPE Armoured Cable USING 150MM DIA GI PIPES (grade A for underground laying and grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS,LUGS, 4 Nos GI 3-Meters LONG pipe, EARTHING, 8 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS, JUMPERING , AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 1772 Supply & Erection for Feeder Bifurcation of 3 phase 11 kV line on 8.5 mtr PCC pole (Weasel conductor) using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 1773 Supply of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel conductor 1774 Erection of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel conductor 1775 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1776 Grouting of 8.5 PCC poleusing 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications: (state practices of PCC pole and base plate/stone to be used) 1777 Supply & Erection ofStone Pad(300x300x75mm) 1778 Supply & Erection for New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1779 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1780 Supply & Erection of 11 KV danger board 1781 Supply & Erection of GI Barbed wire 12 SWG 1782 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1783 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1784 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1785 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1786 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1787 Supply & Erection of 6 SWG GI wire 1788 Supply & Erection of 8 SWG GI wire 1789 Supply & Erection of PG Clamp for Weasel to Weasel conductor 1790 Supply & Erection of Aluminium Jointing sleave for ACSR Weasel 1791 Supply & Erection for Feeder Bifurcation of 3 phase 11 kV line on 8.5 mtr PCC pole (Rabbit conductor)using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 1792 Supply of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbitconductor 1793 Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbitconductor 1794 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1795 Grouting of 8.5 PCC poleusing 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications: (state practices of PCC pole and base plate/stone to be used) 1796 Supply & Erection ofStone Pad(300x300x75mm) 1797 Supply & Erection for New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1798 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1799 Supply & Erection of 11 KV danger board 1800 Supply & Erection of GI Barbed wire 12 SWG 1801 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1802 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1803 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1804 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1805 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1806 Supply & Erection of 6 SWG GI wire 1807 Supply & Erection of 8 SWG GI wire 1808 Supply & Erection of PG Clamp for Rabbit to Rabbit conductor 1809 Supply & Erection of Aluminium Jointing sleave for ACSR Rabbit 1810 Supply & Erection for Feeder Bifurcation of 3 phase 11 kV line on 8.5 mtr PCC pole (Dog conductor) using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 1811 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor 1812 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor 1813 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1814 Grouting of 8.5 PCC poleusing 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) 0.268 cum. etc as per scope of work, approved drawings and specifications: (state practices of PCC pole and base plate/stone to be used,) 1815 Supply & Erection ofStone Pad(300x300x75mm) 1816 Supply & Erection for new 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1817 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1818 Supply & Erection of 11 KV danger board 1819 Supply & Erection of GI Barbed wire 12 SWG 1820 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1821 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1822 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1823 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1824 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1825 Supply & Erection of 6 SWG GI wire 1826 Supply & Erection of 8 SWG GI wire 1827 Supply & Erection of PG Clamp for Dog to Dog conductor 1828 Supply & Erection of Aluminium Jointing sleave for ACSR DOG 1829 Supply & Erection for Feeder Bifurcation of 3 phase 11 kV lineon 11 mtr STP(Dog conductor) using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 1830 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor 1831 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor 1832 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1833 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1834 Supply & Erectio ofStone Pad(300x300x75mm) 1835 Supply & Erection for new 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1836 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1837 Supply & Erection of 11 KV danger board 1838 Supply & Erection of GI Barbed wire 12 SWG 1839 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1840 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1841 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1842 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1843 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1844 Supply & Erection of 6 SWG GI wire 1845 Supply & Erection of 8 SWG GI wire 1846 Supply & Erection of PG Clamp for Dog to Dog conductor 1847 Supply& Erection of Aluminium Jointing sleave for ACSR DOG 1848 Supply & Erection of 11 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 1849 Supply & Erection for 11 KV lineunder ground Railway crossing with 2 nos (Including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) using 150mm dia GI pipes (grade A for underground laying and grade B for pole support), Outdoor heat shrinkable cable jointing kit, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES,CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 1850 Supply & Erection of 12 KV 3ph Indoor type switch gear and 11 KV XLPE cable as per technical specifications, approved drawings and scope of works: 1851 Supply & Erection of Indoor type 12 KV 3 Ph 1250 A VCB with control and protection system for out going feeder consisting ofCT, A-meter, volt-meter, Relays,compliant & accessories complete as per specifications for feeder breaker 1852 Supply & Laying of Cable AL 3X185 sqmm XLPE 11 KV 1853 Supply & Erection of 11 KV cable jointing kit indoor 185 sq.mm. 1854 Supply & Erection of 11 KV cable jointing kit outdoor 185 sq.mm. 1855 Control Cable 1856 Supply & Laying of 4x2.5 mm sq 1857 Supply & Laying of 2x2.5mm sq 1858 Supply & Erection of 11KVAgriculture Feeder Splitting LT line on 8.5 mtr PCC pole with AB cable (3x50+1x35+1x16) due to overloading as per approved drawings, technical specifications and scope of work 1859 Supplyof LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1860 Erection of LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1861 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1862 Concreting of supports with Grounting of 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1863 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1864 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1865 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1866 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1867 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1868 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1869 Supply & Erectionof 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1870 Supply & Erection of 8 SWG GI wire for earthing as per TS 1871 Supply & Erectionof Three phase SMC Distribution box with clamps 1872 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1873 Supply & Erectionof Suspension clamp forLT Aerial Bunched Cable as per TS 1874 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1875 Supply & Erectionof 35 Sqmm PG Clamps as per TS 1876 Supply & Erection of LT Insulation piercing connector 50 -50 sqmm size for phase connection as per TS & approve drawing 1877 Supply & Erection of LT Insulation piercing connector 50-35 sqmm size for phase connection as per TS & approve drawing 1878 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1879 New Distribution Transformer25 KVA 11/433 KV - Supply 1880 Supply & Erectionof 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1881 Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1882 Supply & Erectionof new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel,Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete asper TS & approved drawings. 1883 Supply & Erectionof hot dip galvanized MS Nuts, Bolts with Washers as per TS 1884 Supply& Erection of 11 KV 5 KN Polymer Pin Insulators 1885 Supply& Erection of 11 KV45 KN polymer Disc insulatoras per TS. 1886 Supply& Erectionof suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductoras per TS. 1887 Supply& Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1888 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1889 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1890 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1891 Supply& Erection of 6 SWG GI wire for earthing as per TS 1892 Supply &Erectionof Barbed GI wire 12 SWG 1893 Supply& Erection of PG Clamp suitable for ACSRRabbit conductor as per TS 1894 Supply & Erectionof 11 KV danger board 1895 Supply& Erection of 11 KV, 3-Pole, 3-Ph, 400A, TPMO as per TS 1896 SupplyErection of 11 KV, 3-Ph, 400A, DO Fuse as per TS 1897 Supply & Erectionof 3-Phase, 11/0.4 kV, 25KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS . Energy Efficiency Level-1 1898 Supply & Erection of LT Distribution box with suitable rating MCCB for incomer & MCCBfor two no outgoing feeder suitable for 25 kVA,Dist1ibution Transformer alongwithsuitable for pole mounting as per TS 1899 Supply& Erectionof 9 kV, 5 KA porcelain housing Lightning Arrestorwith Disconnector for DTas per TS. (3 nos=1 set) 1900 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm . 1901 Supply & Erection of Earthing Arrangement ofchemical pipe size of 40x3000 mm. 1902 Supply& Erection of 1-Core 70 mm2, Al. LT XLPE Cable as per TS 1903 Supply & Erection for Augmentation / Reconductoring of 33 kV line With ACSR Panther Conductor of 3 phase 33 kV line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 1904 Supplyof 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther conductor 1905 Erection of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther conductor 1906 Supply & Erection of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1907 Groutingof 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1908 Supply & Erection of 9 m PCC Poles - (PCC Pole as per state practice) 1909 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr PCC Pole of depth1.5 meter with 300 mm Muffing.As per TS. 1910 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1911 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1912 Supply & Erection of 33 KV danger board 1913 Supply & Erection of GI Barbed wire 12 SWG 1914 Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings 1915 Supply & Erection of 33 KV 10 KN Polymer Pin Insulators 1916 Supply & Erection of 8 SWG GI Coil 115 turns (1.85 Kg) 1917 Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1918 Erection of complete stay set with0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1919 Supply & Erection of 6 SWG GI wire 1920 Supply & Erection of 8 SWG GI wire 1921 Supply & Erection of PG Clamp for Panther to panther conductor 1922 Supply & Painting of silver paint 1923 Supply & Painting of red oxidepaint 1924 Dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store . 1925 Supply & Erection ofAugmentation / Reconductoring of 11KV line With ACSR DOG Conductorof Feeder ( Older than 25 years ) as per approved drawings, technical specifications and scope of work 1926 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor on 11 Mtr STP 1927 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor on 11 Mtr STP 1928 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1929 Erection of 8.5 PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 0.268 cum Cement concreting+0.014 cmt (Muffing) 1930 Supply & Erection for Augmentation of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1931 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1932 Supply & Erection of 11 KV danger board 1933 Supply & Erection ofStone Pad(300x300x75mm) 1934 Supply & Erection of GI Barbed wire 12 SWG 1935 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1936 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1937 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1938 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1939 Erection of complete stay set with0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1940 Supply & Erection of 6 SWG GI wire 1941 Supply & Erection of 8 SWG GI wire 1942 Supply & Erection of PG Clamp for Dog to Dog conductor 1943 Supply & Erection of Augmentation / Reconductoring of 11KV line With ACSR Rabbit Conductor of Feeder ( Older than 25 years ) as per approved drawings, technical specifications and scope of work 1944 Supplyof 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor- On 11 mtr STP 1945 Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor- On 11 mtr STP 1946 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1947 Erection of 8.5 PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 0.268 cum Cement concreting+0.014 cmt (Muffing) 1948 Supply & Erection for Augmentation of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1949 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1950 Supply & Erection of 11 KV danger board 1951 Supply & Erection of StonePad(300x300x75mm) 1952 Supply & Erection of GI Barbed wire 12 SWG 1953 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1954 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1955 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1956 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1957 Erection of complete stay set with0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1958 Supply & Erection of 6 SWG GI wire 1959 Supply & Erection of 8 SWG GI wire 1960 Supply & Erection of PG Clamp for Rabbit to Rabbit conductor 1961 Supply & Erection of Automatic Capacitor Bank as per approved drawings, technical specifications and scope of work (1.98 MVAr With APFC Panel) 1962 Supply & Erection of 12.65 kV, 1980 kVAr, 3-Phase, 50 C/s, housed in Outdoor Type CRCA panel, Capacitor bank having two variable step of 792 Kvar & one Variable steps of 396 kVAr. Bank shall be complete with Capacitor units of 264/132 kVAr,Aluminium busbars, Epoxy insulators, HT HRC fuse,Surge suppressor etc.with details as follows-(1 )11 KV Alumuniumwound ,Dry type series reactor(a)0.528 KVAr for 792 KVAr step-6 nos. (b)0.264 KVAr for 396 kVAr step-3 nos. (2) 11 kV, 3-Phase Indoor Dry Type RVT-1 nos. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor-3 nos. (4) Indoor Type Automatic Control Unit-1 No. (5) IP 55, outdoor CRCA cubicle panel for accommodating capacitors, series reactors, vacuum contactor, surge supressor etc., along with FRP canopy-1 No. 1963 Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(1.98 MVAr HT Capacitor bank) 1964 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(1.98 MVAr HT Capacitor bank) 1965 Supply & Erection of Indoor Type Automatic Control Unit(1.98 MVAr HT Capacitor bank) 1966 Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(1.98 MVAr HT Capacitor bank) 1967 Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(1.98 MVAr HT Capacitor bank) 1968 Supply &Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(1.98 MVAr HT Capacitor bank) 1969 Supply &Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(1.98 MVAr HT Capacitor bank) 1970 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(1.98 MVAr HT Capacitor bank) 1971 Supply & Erectio of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(1.98 MVAr HT Capacitor bank) 1972 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(1.98 MVAr HT Capacitor bank) 1973 Casting of Civil foundation(1.98 MVAr HT Capacitor bank) 1974 Cable trench for laying of power/control cables.(1.98 MVAr HT Capacitor bank) 1975 Supply & Erection of 3.96 MVAr With APFC Panel 1976 Supply & Erection12.65 kV, 3960 kVAr, 3-Phase, 50 C/shoused in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set 1977 Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank) 1978 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank) 1979 Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank) 1980 Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank) 1981 Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank) 1982 Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank) 1983 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank) 1984 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank) 1985 Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank) 1986 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(3.96 MVAr HT Capacitor bank) 1987 Casting of Civil foundation(3.96 MVAr HT Capacitor bank) 1988 Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank) 1989 Supply & Erection of Earthing of existing substation and Distribution Transformer 1990 Supply & Erection of Pipe rod earthing with 3000mm long, 40 mm diameterGI pipe, GI Strip of 24x3mm. 1991 Supply & Erection of Spike Earthing 20mm X 2500 mm GI solidRod 1992 Supply & Erection of 8 SWG GI wire for earthing 1993 Supply ,Erection,Design & Engineeringof Renovation and Modernization of Existing Substation, Battery Charger and Battery set 1994 Supply & Erection of24V, 150 AHPb(Lead) Acid battery, battery standmade of teakwood duly painted with anti acid resistive paint, battery insulators, inter-battery wiring using 30 sqm, 1.1 kv, copper single coremulti strand cable, terminal connectors, Rubber mats & all other accessories and connectors as per technical specifications. 1995 Supply & Erection of 24V, 150 AH.Float-cum-Boost Battery Charger with full wave rectification for230V,1 phase, 50 Hz AC Input Supply & Erection as per technical specifications. 1996 Supply & Erection of36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 1997 Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds,400-200/1-1 Amps ( having 3 secondery, core),type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 1998 Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds,33 Kv/110 V single core outdoortype Potential Transformers along with junction box, as required as per technical specifications complete in all respect. 1999 Supply & Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete(1 set= 3 Nos.) 2000 Supply & Erectio of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch) 2001 Supply & Erection of 33 kV feeder Panel (without diffirential relays)complete 2002 Supply & Erectionof 12 KV 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 2003 Supply & Erection of 11 KV 400-200/5-5 AMP moulded CT 2004 Supply & Erection of Indoor Type 11KV/110/√3 V 3-Phase PT for Indoor Type Control & Relay panel 2005 Supply & Erection of 9kV, 10kA, 1-ph Station Class LighteningArrester complete (1 Set = 3 Nos.) 2006 Suplly &Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt. 2007 Supply & Erection of 11 kv Bus-Coupler with all required accessories complete as per technical specifications, scope of works and approved drawings . 2008 Supply of 3CX300 Sqmm 33 KV XLPE Armored Cable 2009 Erection of 3CX300 Sqmm 33 KV XLPE Armored Cable 2010 Supplyof 3Cx185 Sqmm 11 KV XLPE Armored Cable 2011 Erection of 3Cx185 Sqmm 11 KV XLPE Armored Cable 2012 Civil Worksfor Control room extension, Strengthning and Miscellaneous Works required as per Scope of work, Approved drawings and Technical Specifications. 2013 Design, Engineering construction of Control room building extension 300 Sq feet for installation of Capacitor Bank pannel, including cost ofall materials, T&P and Labour,etc. as per Technical specification and approved drawing as per direction of Employer 2014 Design, Engineering construction of Control room building extension 300 Sq feet for installation of pannels for additional T/F, including cost ofall materials, T&P and Labour,etc. as per Technical specification and approved drawing as per direction of Employer 2015 Design, Engineering construction of Control room building extension 300 Sq feet for installation of pannels for Augmentation ofT/F, including cost ofall materials, T&P and Labour,etc. as per Technical specification and approved drawing as per direction of Employer 2016 Old Conrol RoomBuilding Strengthning & Miscellaneous Construction Works required as per Scope of work, Approved Drawings and Technical Specifications 2017 Construction of boundary wall (200 mtr for each substation) as per Scope of work, approved drawings and Technical specifications. 2018 Construction offire wall between two Power Transformes at Existing 33/11 KV S/S as per Scope of work, approved drawings and Technical specifications. 2019 Supply & Erection of DT Capacitor with Fitting as per Technical Specification, Approved Drawing and scope of work 2020 Supply & Erection of LT Shunt capacitor 440 Volt 10 KVAr 3Phase 50Hz IP65 2021 Supply & Erection of LT Shunt capacitor 440 Volt 25 KVAr 3Phase 50Hz IP65 2022 LT Line with 1CX25 sqmm LT armoured XLPE Cablein high loss area 2023 Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) 2024 Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31 2025 Groutingof 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 2026 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 2027 Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work 2028 Supply & Erection of Stone Pad 300X300X75 2029 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 2030 Erection of complete stay set with0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 2031 Supply & Erection of Single core XLPE armoured cablesingle phase2 wire as per technical specifications, approved drawings and scope of work. 2032 Supply & Erectio of 1.1 kV Single Core 25sqmm XLPE armoured cable (1Cx25 sqmm) 2033 Supply & Erection of Angle for vertical ArmL50x50x6 (Type -A)-900MM 2034 Supply & Erection Angle for vertical ArmL50x50x6 (Type -B)- 900MM 2035 Supply & Erection of C-Clamp with Nut & bolts 2036 Supply & Erection of LT shakle insulator 2037 Supply & Erection of Distribution tie for shakle insulator 2038 Supply & Erection of Mid span joint 25sqmm 2039 Supply & Erection ofInsulation mastic tape (2inc X 10 feet). 2040 Supply & Erection ofSatellite Multi-Tap Connector as per TS 2041 Supply & Erection ofSingle Phase SMC Distribution Box with clamps 2042 Supply & Erection of 2Cx25 SQMM Stranded Unarmoured Cable (Al Conductor ) for chargingSingle Phase DB 2043 Supply & Erection of Spike Earthing 20mm X 2500 mm GI solidRod 2044 Supply & Erection of 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers 2045 Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box 2046 Supply & Painting of silver paint 2047 Supply & Painting of red oxidepaint 2048 Removing and shifting of Existing Material to client store 2049 LT Line with 1CX120 sqmm LT XLPE Armoured Cable in high loss area 2050 Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) 2051 Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31 2052 Groutingof 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 2053 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 2054 Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work 2055 Supply & Erection of Stone Pad 300X300X75 2056 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 2057 Groutingstay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 no.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 2058 Supply & Erection of Single core XLPE armoured cablefor three pahse 4 wire as per technical specifications, approved drawings and scope of work. 2059 Supply & Erection of 1.1 kV Single Core 120sqmm XLPE armoured cable (1Cx120 sqmm) 2060 Supply & Erection of LT cross arm arrangement angel (50x50x6mm) (50x8mm) (weight-9.41 kg)with Nuts and bolts 2061 Supply & Erection of LT cross arm arrangement angel (75x75x8mm) (65x8mm) (weight-18.6 kg) with Nuts and bolts 2062 Supply & Erection of C-Clamp with Nut & bolts 2063 Supply& Erectionof LT shakle insulator 2064 Supply & Erection of Distribution tie for shakle insulator 2065 Supply & Erection of Mid span joint 120sqmm 2066 Supply & Erection of Insulation mastic tape (2inc X 10 feet). 2067 Supply & Erection of Satellite Multi-Tap Connector as per TS 2068 Supply & Erection of Three Phase SMC Distribution Box with clamps 2069 Suppply & Erectionof 4Cx35SQMM Stranded Unarmoured Cable (Al Conductor ) for chargingThreePhase DB 2070 Supply & Erection of Spike Earthing 20mm X 2500 mm GI solidRod 2071 Supply & Erection of 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers 2072 Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box 2073 Supply & Painting of silver paint 2074 Supply & Painting of red oxidepaint 2075 Removing and shifting of Existing Material to client store 2076 LT Line with 1CX95 sqmm XLPE Armoured Cable in high loss area 2077 Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) 2078 Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31 2079 Groutingof 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 2080 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 2081 Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work 2082 Supply & Erection of Stone Pad 300X300X75 2083 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 2084 Groutingstay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 no.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 2085 Supply & Erection of Single core XLPE armoured cable for three phase4 wireas per technical specifications, approved drawings and scope of work. 2086 Supply & Erectionof 1.1 kV Single Core 95sqmm XLPE armoured cable (1Cx95 sqmm) 2087 Suppl & Erection of LT cross arm arrangement angel (50x50x6mm) (50x8mm) (weight-9.41 kg)with Nuts and bolts 2088 Supply & Erection of LT cross arm arrangement angel (75x75x8mm) (65x8mm) (weight-18.6 kg) with Nuts and bolts 2089 Supply & Erection of C-Clamp with Nut & bolts 2090 Supply & Erection of LT shakle insulator 2091 Supply & Erection of Distribution tie for shakle insulator 2092 Supply & Erection of Mid span joint 95sqmm 2093 Supply & Erection of Insulation mastic tape (2inc X 10 feet). 2094 Supply & Erection of Satellite Multi-Tap Connector as per TS 2095 Supply & Eection of Three Phase SMC Distribution Box with clamps 2096 Suppply of 4Cx35SQMM Stranded Unarmoured Cable (Al Conductor ) for chargingThreePhase DB 2097 Supply & Erection of Spike Earthing 20mm X 2500 mm GI solidRod 2098 Supply & Erection of 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers 2099 Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box 2100 Supply & Painting of silver paint 2101 Supply & Painting of red oxidepaint 2102 Removing and shifting of Existing Material to client store 2103 LT Line with 1CX50 sqmm XLPE Armoured Cable in high loss area 2104 Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) 2105 Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31 2106 Groutingof 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 2107 Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtrmtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 2108 Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work 2109 Supply & Erection of Stone Pad 300X300X75 2110 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 2111 Grouting of stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 no.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 2112 Supply & Erection of Single core XLPE armoured cablefor three pahse4 wire as per technical specifications, approved drawings and scope of work. 2113 Supply & Erection of 1.1 kV Single Core 50sqmm XLPE armoured cable (1Cx50 sqmm) 2114 Supply & Erection of LT cross arm arrangement angel (50x50x6mm) (50x8mm) (weight-9.41 kg)with Nuts and bolts 2115 Supply & Erection of LT cross arm arrangement angel (75x75x8mm) (65x8mm) (weight-18.6 kg) with Nuts and bolts 2116 Supply & erection of C-Clamp with Nut & bolts 2117 Supply & Erection of LT shakle insulator 2118 Supply & Erection of Distribution tie for shakle insulator 2119 Supply & Erection of Mid span joint 50sqmm 2120 Supply & Erection of Insulation mastic tape (2inc X 10 feet). 2121 Supply & Erection of Satellite Multi-Tap Connector as per TS 2122 Supply & Erection of Three Phase SMC Distribution Box with clamps 2123 Suppply& Erection of 4Cx35SQMM Stranded Unarmoured Cable (Al Conductor ) for chargingThreePhase DB 2124 Supply & Erection of Spike Earthing 20mm X 2500 mm GI solidRod 2125 Supply & Erection of 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers 2126 Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box 2127 Supply & Painting of silver paint 2128 Supply & Painting of red oxidepaint 2129 Removing and shifting of Existing Material to client store 2130 Discount offered in % 2131 Words Final Quoted Price after Discount

Key Value

Document Fees
INR 29500 /-
EMD
INR 50000000.0 /-
Tender Value
INR 564.83 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail