| 1 | DEVELOPMENT OF SEEMA DARSHAN FACILITY AT LAMANG |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas ( exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 M, disposed earth to be levelled and neatly dressed. Ordinary Rock |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each layer by ramming and watering, lead up to 50m and lift upto 1.5m |
| 4 | Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete |
| 5 | Supplying chemical emulsion in sealed containers including delivery as specified (a) Chlorpyriphos Emulsifiable concentrate 20% with 1% @ 1.0 ltr per sqm of covered area. |
| 6 | Stone soling under floors including watering, ramming consolidating and dressing complete: upto 5 km |
| 7 | CONCRETE WORK |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering in footings and bases of columns (All work upto plinth level). 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources)Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4graded stone aggregate 20 mm nominal size). |
| 9 | R.C.C. WORK |
| 10 | Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centering, shuttering, finishing and reinforcement-M-25 grade reinforced concrete.All work upto floor plinth level. |
| 11 | Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centering, shuttering, finishing and reinforcement-M-25 grade reinforced concrete. All work from plinth level upto floor roof lvl. |
| 12 | FORM WORK |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete. Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies, shelves and access platform. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressummers and cantilevers. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts.Centering and shuttering including strutting, propping etc. and removal of form for: RampsCentering and shuttering including strutting, propping etc. and removal of form for: Walls |
| 16 | STEEL REINFORCEMENT |
| 17 | Reinforcement of RCC work including straightening, cutting, bending, placing in position and binding all complete. Cold Twisted Bars |
| 18 | BRICK WORK |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 20 | Providing half brick masonry with bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement :3 coarse sand) in superstructure. |
| 21 | FLOORING |
| 22 | Providing and fixing 1 st quality ceramic glazed wall tiles confirming to IS: 15622 ( thickness to be specified by manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any sizes as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 Coarse sand) and joining with grey cement slurry @3.30kg per sqm including pointing with white cement mixed with pigment of matching shade complete. |
| 23 | Providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS: 15622 of approved make in colours such as white, lvory, Grey, FUME Red Brown, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), including pointing the joints with white cement and matching pigment etc. complete. |
| 24 | Providing and laying vitrifiedfloor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption\"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 60x 60 cm |
| 25 | FINISHING |
| 26 | 12 mm thk cement plaster 1: 4 ( 1 cement : 4 coarse sand) on walls. |
| 27 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 Cement : 4 Coarse Sand) |
| 28 | 6 mm thick cement plaster ( 1 cement : 3 fine sand) to ceiling. |
| 29 | Providing and applying white cement based putty of avg thickness 1.0 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 30 | White washing with lime to give an even shade. New Work (Three or more coats). |
| 31 | Finishing walls with water proofing cement paint of approved brand and maufacture and of required shade to give an even shade |
| 32 | Applying one coat of cement primer approved brand and manufacturer on wall surface : |
| 33 | WOOD WORK |
| 34 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : Kiln seasoned and chemically treated hollow wood |
| 35 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part-I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick includingISI Marked Stainless Steel butt hinges with necessary screws. |
| 36 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) Transparent or dyed to required colour or shade, with necessary screws etc. complete: 125mm |
| 37 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin Rubber Stopper |
| 38 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. 250 x 10 mm |
| 39 | Providing and fixing MS grills of required pattern in frames of windows etc. with MS Flats, square or round bars etc.including priming coat with approved steel primer all complete. Fixed to Steel Windows by welding |
| 40 | STEEL WORK & ROOFING |
| 41 | Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes. |
| 42 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 43 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500-600 mm). |
| 44 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) |
| 45 | Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. False Ceiling |
| 46 | Weight to be carried by head load from Manigong to work site. |
| 47 | Point wiring in PVC conduit, with modular type switch : Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insultated copper conductor single core cable in surface/recessed PVC conduit,with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required Group C. |
| 48 | Circuit/ Sub -Main wiring in PVC Conduit : Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire (for ckt wiring) |
| 49 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire (for power plug) |
| 50 | 2 x 6 sq. mm + 1 x 6 sq. mm earth wire |
| 51 | 2x10 sq.mm+ 1x10sq. Mm earth wire.(for Common Area DB) |
| 52 | 4x10 sq.mm+ 2x10sq. Mm earth wire.(for DB\"s) |
| 53 | 4x16 sq.mm+ 2x16sq. Mm earth wire.(for DB\"s) |
| 54 | Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required : 3 X 4 Sq. mm |
| 55 | Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required : 3 X 6 Sq.mm |
| 56 | TV Cable in existing Conduit |
| 57 | Supplying and drawing co-axial TV Cable RG - 6 grade, 0.7 mm solid copper conductor PEinsulated, shielded with fine tinned copper braid and protected with PVC sheath in thye existing surface/ recessed steel/ PVC conduit as required. |
| 58 | S/F PVC conduit |
| 59 | S/F PVC Conduit : Supplying and fixing of following sizes of medium classPVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm |
| 60 | S/F Modular Type Switch/ Socket : Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch |
| 61 | S/F Modular Type Switch/ Socket : Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet |
| 62 | TV Antenna Socket Outlet |
| 63 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 64 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm x 75mm) |
| 65 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.4 Module (125 mm x 75 mm) |
| 66 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch,connection,painting etc. as required. |
| 67 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 68 | Installation, testing and commissioning of ceiling fan including the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insualted,copper conductor,single core cable and earthing etc. as required. |
| 69 | Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan,making good the damage, coonection,testing,commissioning etc. as required |
| 70 | Extra for fixing louvers/shutters complete with frame for a exhaust fan of all sizes. |
| 71 | Supplying and fixing following way,single pole and neutral, prewired, sheet steel,MCB distribution board, 240 volts, on surface/recess,complete with loose wire box,terminal blocks,duly prewired with suitble size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) (2+4) Way Double Door |
| 72 | Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/recess complete with loose wire box,terminal connectors for all incoming & outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar,detachable gland plate,interconnections, powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) 8 Way (4+24), Double Door |
| 73 | Supplying & fixing following ways surface/ recess mounted, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s, with provision of 100 amps TP 16 KA MCCB as in comer, interconnection between incomer MCCB & busbars (but without MCB\"s/ MCCB) as required.( Note: Vertical type MCB TP DB is normally used where 3 Phase outlets are required.) 8 way TP |
| 74 | Providing & fixing following rating & breaking capacity & pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connection, etc. as required. 100 Amp, 16 KA, TP MCCB |
| 75 | Supplying and fixing 5 amps to 32 amps rating,240/415 volts, \"C\"series,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. Single Pole |
| 76 | Supplying and fixing following rating ,double pole (single phase and neutral ),240 Volts,residual current circit breaker (RCCB), having senstivity crrent up to 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32 amps |
| 77 | Supplying & Fixing 20 Amps, 240Volts, SPN Industrial Type Socket Outlet, with 2 Pole and earth, metal enclosed plug top alongwith 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing & commissioning as required. |
| 78 | Providing & fixing M.V danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red color on front side as required |
| 79 | Earthing with G.I earth pipe 4.5 mtr long , 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc.with charcoal and salt complete as required.( External Poles) |
| 80 | Earthing with G.I earth plate 600mm X 600 mm X 6 mm thick including accessories, & providing mansonary enclosure with cover plate having locking arrangement & watering pipe of 2.7 Metre long etc. with charcoal/ coke & salt as required( Equipments) |
| 81 | Earthing with copper earth plate 600mm X 600 mm X 3 mm thick including accessories, & providing mansonary enclosure with cover plate having locking arrangement & watering pipe of 2.7 Metre long etc. with charcoal/ coke & salt as required |
| 82 | Providing and fixing 25 mm x 5 mm G.I earth stripfrom earth electrode as required. |
| 83 | Providing and fixing 6 SWG dia GI wireon surface or in recess for loop earthing as required |
| 84 | Non Schedule items: |
| 85 | Supplying the following Lighting fixtures including lampsatsite.Rate shall include all taxesandduties, transportation etc. complete. Use all Philips Trulite/Osram lumilux plus Eco lamps in Fluorescent lamp fittings. ( 4000 K)Use Osram CFL lamp - Dulux L Lumilux in all CFL lamp fixtures (4000 K) (Samples of all light fixtures to be submitted to the client for approval prior to procurement of fixtures). 2 X 36 watts CFL recessed mounted light fixture as per Wipro Cat. No. WVP 74236 |
| 86 | 12\" dia 1 phase exhaust fan, 1400 RPM |
| 87 | 2x18 Watt CFL Light fixture as per Wipro Cat. No. WCP 36218 SGW or as equivalent |
| 88 | 48\" dia (1200 sweep) ceiling fan |
| 89 | Sanitary fixtures & Accessores : |
| 90 | Providing and fixing white vitereous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern including flush pipe with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. W.C pan with ISI marked white solid plastic seat and lid. |
| 91 | Providing and fixing wash basin with CI brackets,15mm brass pillar taps,32mm CP brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required. White Vitreous china Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap |
| 92 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 32 mm dia (for wash basin) |
| 93 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 40 mm dia(for sink and urinal) |
| 94 | Providing & Fixing 600 X 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 95 | Providing & fixing viterous china toilet paper holder. |
| 96 | Providing & fixing stainless steel A ISI 304(18/8) kitchen sink as perI.S 13983 with C.I. brackets and stainless steel plug40 mm including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board. 510 x 1040 bowl depth 250 mm |
| 97 | Water supply pipes and fitting : |
| 98 | Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting cheases and making good the walls etc.15mm nominal outer dia pipes |
| 99 | Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting cheases and making good the walls etc. 20mm nominal outer dia pipes |
| 100 | Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting cheases and making good the walls etc. 25mm nominal outer dia pipes |
| 101 | Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This including jointing of pipes & fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge. 40 mm Nominal outer dia pipes |
| 102 | Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 25mm nominal bore |
| 103 | Providing & fixingunplasticised PVC connection pipewith brass unions. 15 mm nominal bore45 cm long |
| 104 | Providing & fixingCP brass bib cockof approved quality conformingtoIS 8931. (15 mm nominal bore) |
| 105 | Providing and fixingC.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms (15 mm nominal bore). |
| 106 | Providing and fixing brass stop cock of approved quality: 15mm Nominal Bore |
| 107 | Providing & fixingC.P brass shower rose with 15mm inlet. (100 mm dia). |
| 108 | Part B Non Scheduled Items :- |
| 109 | Providing and fixing of C.P. Brass health faucet for ablution with 1 meter long PVC tube, hand shower, couplings, wall hook and other accessories. (Jaquar 573 or equivalent) |
| 110 | Providing and fixing of32 mm dia. C.P.Brass bottle trap with 190 mm long wall connection pipe in place of P.V.C. waste pipe for wash basin discharge. (Jaquar 773 or equivalent) |
| 111 | Providing and fixing of 600 mm long C. P. brass towel railcomplete with C.P. brass brackets . (Jaquar 1111 or equivalent) |
| 112 | Providing and fixing of 15 mm dia. inletC.P. brass adjustable shower with 190 mm long shower arm complete with flange of approved quality. (Jaquar 477 + 493 or equivalent) |