}

Tender For Baruasagarnagar Palikaparishad Reorganization Water Supply Scheme Under Amrut 2.0 Survey Soil Investigation Design Supply Of All Materials Labour Tandp Etc Required For Construction Erection Completion Testing And Commissioning Of Water Supply , Jhansi-Uttar Pradesh

Uttar Pradesh Jal Nigam has published Tender For Baruasagarnagar Palikaparishad Reorganization Water Supply Scheme Under Amrut 2.0 Survey Soil Investigation Design Supply Of All Materials Labour Tandp Etc Required For Construction Erection Completion Testing And Commissioning Of Water Supply . Submission Date for this Tender is 30-09-2024. Building Work Tenders in Jhansi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45254556
Tender For Baruasagarnagar Palikaparishad Reorganization Water Supply Scheme Under Amrut 2.0 Survey Soil Investigation Design Supply Of All Materials Labour Tandp Etc Required For Construction Erection Completion Testing And Commissioning Of Water Supply
Open Tender
Indian
Uttar Pradesh
Jhansi
30-09-2024

Tender Details

tender for Baruasagarnagar Palikaparishad Reorganization Water Supply Scheme Under Amrut 2.0 Survey Soil Investigation Design Supply Of All Materials Labour Tandp Etc Required For Construction Erection Completion Testing And Commissioning Of Water Supply Works Such As Wtp Rcc Oht Zps Cwr Cum Pumping Station Rising Main Feeder Main, BARUASAGAR NAGAR PALIKA PARISHAD REORGANIZATION WATER SUPPLY SCHEME UNDER- AMRUT 2.0, DISTT. JHANSI Sl. No. Item Description 1 CIVIL WORK 2 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for Design and Drawing, Supply of all materials, labour, T&P etc. required for construction,of specified capacity (3.6MLD) of WTP based on 20 Hrs. operation (3.6MLD + 25%) extra over loading capacity includinginlet chamber, aeration fountain / cascade, inlet channels including mechanical/manual fine/coarse screens, flash mixer, mixing channel with Parshall flume and flow measuring arrangement, clariflocculator with conventional, filter house and filter plant including back wash tank and back wash pumps with 100% standby, chemical house, coagulant feed tank with feed mechanism, poly aluminium chloride (PAC) or other coagulant tank of specified capacity and nos. with mixing and dosing arrangement complete, vacuum feed gas chlorinator with 100% standby, sludge handling unit and recycling of collected water from sludge etc. complete,All WTP scada Opratedexternal and internal electrification, laboratory building with all specified lab equipment, admin building, Quarter (One no.), sanitary block with necessary water supply and drainage arrangement, campus roads, landscaping and other campus development works, rain water harvesting, etc. all required works complete as per the direction of Engineer-in-Charge.The WTP shall be fully automatic based on PLC/SCADA with real time remote monitoring system and online contineuous effluent monitoring system. 3 For water works compound Construction of Bituminious approach road including preparation of subgrade. 4 Earth filling inside the water works campus. 5 Cutting of bushes, removing garbage form w/w site and dewatering of sub soil water at wtp & including maintinance of existingintake well Painting of intake well and existing water works campus 6 CONSTRUCTION OF SUMP-CUM-CLEAR WATER RESERVOIR-CUM-PUMP HOUSE OF 250 KL CAPACITY AT ZONE-3WATER WORKS CAMPUS (CWR) 7 RCC CWR;Detailed Survey, Design and Drawing, supply of all material, labour, T&P etc. required for construction of250 KL Ractangular, R.C.C Clear Water Reservoir cum pump house including various works like 1 m wide stair case with stainless steel hand railing to go inside reservoir, sump below the pump house area, stainless steel railing over the R.C.C slab of reservoir, Granular texture finish on exterior surface of pump house, gantry beam, food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, kota ston floring,bypass arangment ,and soil testing for Bearing capacity of capacity mentioned as under:Note : The bid prices of Clear Water Reservoir / Pumping Stations are to be submitted considering the depth of excavation may extend up to 6 m BGL. Design and Drawing approved by competent authority and Design vetted by Reputed Govt. Engineering College.(250 KL capecity) 8 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for , Design,Drawing includingSupply of all materials, labour, T&P etc. required for construction, Construction ofLT Panel Room (RCC Frame Structure) as per type design (5m x 5m x 4 m) 9 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for , Design,Drawing includingSupply of all materials, labour, T&P etc. required for construction, Construction ofMeterRoom (RCC Frame Structure) as per type design (4m x 4m x 4 m) 10 Estimate of RCC OverHead Tank of 450 KL. Capacity / 22 M. Staging FOR ZONE -3 Barua Sagar 11 450 KL 22 M Staging Survey Design , drawing and Supply of all materials, labour and T&P etc. complete for the construction of OHT of 450 KL. capacity and staging 22 M with 1.00 m. wide P.C.C. appron all around with 15 cm. Semi circular P.C.C. drain, 1 m. wide RCC stair case from ground level upto balcony, M.S. Ladder with hand rails on both sides from balcony to top dome and inside the tank, 1 m wide RCC balcony alround the tank wall with proper railings of 20 mm. dia. medium quality G.I. pipes in 3 rows on both sides of staircase, balcony and at the top of domes and at each landing supported on RCC posts spaced at not more than 1.50 m. intervals, proper ventilators at top, electronic water level indicator with invertor, Lightening conductor as per latest I.S. code or electricity rules, 600 mm. dia. medium pattern C.I. Manhole cover hinged with locking arrangement, fixing and jointing vertical DID/F pipes, specials and duck foot bends of required size for Inlet, outlet, fixing of outlet sluice valve and washout sluice valves with all jointing materials for proper completion and other appurtenant works, including excavation in all type of soils, painting on exposed surface with one coat of primer and two coats of approved weather coat paint, painting of vertical pipes and railings with approved anticorrosive paints and also including testing of the Overhead Tank, including following items : Supply of following sizes of DID/F pipes conforming to IS 8329 / 2000 or its latest amendment upto rail head including all taxes, duties, insurance etc. Inlet pipe 250 mm. dia.,Outlet pipe 300 mm. dia.,Overflow pipe 300 mm. dia.Washout pipe 100 mm. dia.Carting of above size DI K-9 of pipes upto site of works and lowering them into the trenches and laying true to alignment and gradient and jointing of pipes complete ( including testing of pipelines and cutting of pipes for making up the length excluding the cost of trenches. ) Inlet pipe 350 mm. dia. Outlet pipe 400 mm. dia. Overflow pipe 300 mm. dia. Washout pipe 100 mm. dia . Supply of following diameter ISI Mark Sluice Valve conforming to IS 780/ 1984 or its latest amendment of standard make ( Kirloskar or IVC make ) including all taxes etc. and carting, loading and uploading upto departmental store and carting of following fittings / specials to the site of work, lowering them into the trenches, fixing in position and jointing them with pipe lines, fixing in position and jointing them with pipelines and testing etc. complete including supply of all jointing materials. 400 mm. dia. ( In outlet pipe )100 mm. dia. ( In washout pipe ) Supply of all materials, labours, T&P etc. all complete to construct sluice valve chamber of following sizes.For Outlet Pipe For Washout Pipe Provision for the disposal of overflow water, washout water from chambers to nearest suitable point of disposal including supply of pipes, its laying, jointing, excavation and protection works at the point of disposal. including Provision for soil testing. 12 DISTRIBUTION SYSTEM OF BARUASAGAR ZONE-1,2 and 3 and CLEAR WATERGRAVITY MAIN FROM WTP TO ZONAL WATER WORKS AND RISING MAIN FORZONES-03 (Chui Khadan) BARUASAGAR NAGAR PALIKA PARISHAD 13 Excavation for pipe line trenches in soil mix / all type of rocks with moorum/shingles/kanker requiring use of special T&P ie. pick axe, sabbals etc. lift upto 1.50 m lead upto 50 m. stacking and spreading as directed, normal dewatering,preparing the bed,Filling watering ramming of excavated earth into pipe line trenches and disposal of surplus earth upto a distance of 10 KM from the centre of the pipe line trenches 14 0.00 To 1.5 m Depth 15 Same as above but excavation in all type of rock 16 0.00 To 1.5 m Depth 17 Supply of ISI mark DI K-9 and K-7 S&S pipes (push on joints) of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) andand Supply of specialsconforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. with jointing Materials including all taxes, freight, loading, unloading, insurance, duties etc., all complete. and supply of all DI DF/DI DS specialslike Tees, all type bend ( For Distribution, Feedermain And Rising main Purpose ) 18 80 mm Dia DI K-7 19 100 mm diaDI K-7 20 125 mm diaDI K-7 21 150 mm diaDI K-7 22 200 mm dia Distribution system and Junction (B-D) to Cwr at zone -3DI K-7 23 250 mm diaDI K-7 24 200 mm dia DI-K-9 25 Lowering, laying and jointing with SBR ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete.Carting of following sizes (Dia. in mm.) of pipes and specials including jointing mateirals from store to site of work lowering the same into excavated pipe line trenches true to alignment and gradient and jointing the same including testing of pipe line including supply of all materials labour T&P etc complete and as per direction of Engineer Incharge. 26 80 mm Dia 27 100 mm dia 28 125 mm dia 29 150 mm dia 30 200 mm dia Distribution system and Junction (B-D) to Cwr at zone -3 31 250 mm dia 32 200 mm dia DI-K9 Zone-3 33 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 PN 1.0 34 D.I.Sluice valve 35 100 mm dia 36 150 mm dia 37 200 mm dia 38 250 mm dia 39 Fire Hydrant as per IS Code 908 : 1975 40 65 mm Dia 41 Air valves as per IS 14845 : 2000 PN 1.0 42 50 mm Dia 43 20mm Dia 44 Scour valves 45 50 mm dia 46 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 PN 1.0 47 100 mm dia 48 150 mm dia 49 200 mm dia For Zone -3 50 250 mm dia 51 Fire Hydrant as per IS Code 908 : 1975 52 65 mm Dia 53 Air valves as per IS 14845 : 2000 PN 1.0 54 50 mm Dia 55 20 mm Dia 56 Scour valves 57 50 mm dia 58 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 59 Sluice valve chambers (Masonry type) 60 100 mm to 250 mm dia 61 Scour valve chambers (Masonry type) 62 Fire hydrantschambers 63 Air valve chambers 64 Dismantling (cutting by sharp eage machine tools) and Reinstatment of following type of road surfaces for laying of pipe line and house connection work including sorting out of serviceable materials and disposal of unserviceable materials. 65 Bituminious Road 66 Cement Concrete Road (CC) 67 Interlocking Tiles Road 68 Construction of thurst block in RCC 1:2:4 at bends & Tee in feeder main including supply of all labour, material, T&P etc. complete as per the details given below :- 69 Mild steel or iron work in R.C.C. wrought to required shape as necessary including bending for proper completion of the work including supply of steel and wastage etc. 70 Provision for crossing of Nalas (0.5mto 2.0 m innerwidth) for laying of pipe line including necessary specials, T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain. 71 0.5 - 1.0 m 72 1.0 - 1.5 m 73 1.5 - 2.0 m 74 Providing new water supply house connection to the consumersfrom new distribution pipe line of following diametersincluding making ferrule connection, cost of ferrule, 15 mm dia HDPE and GI pipe, saddle piece, ball valve, specials, excavation, refilling of pit etc. complete. It also includes supply of all materials, labour, T&P Including Dismentling and Reinstatment etc. required for proper completion of the work. As per attached drawing. 75 In all tupe of soil and rock 76 Bituminious Road 77 For 80 to 100 mm dia 78 For 125 to 150 mm dia 79 For 200 mm dia 80 Cement Concrete Road 81 For 80 to 100 mm dia 82 For 125 to 150 mm dia 83 For 200 mm dia 84 Interlocking Tiles Road 85 For 80 to 100 mm dia 86 For 125 to 150 mm dia 87 For 200 mm dia 88 Kachha Road 89 For 80 to 100 mm dia 90 For 125 to 150 mm dia 91 For 200 mm dia 92 Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 93 Brick masonry in cement mortar 1:4 94 12mm thick plaster in cement mortar 1:4 95 RCC M-20 (including MS work) 96 Stone masonry in cement mortar 1:6 97 Shifting of Existinghouse connection from existing pipe line to new pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 98 Repairing of house connection which is coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 99 Barricating of pipe line trenches by using bamboo poles,sheets, rope with red flags, Glow-caution boards, diversion boards & red lights Complete as per the direction of engineer incharge 100 Interconnection of existing pipe line to new pipe line including fitting special pipe, tee, bend, reducer pipe all complete as per site requirment T&P etc material complete as per the direction of engineer incharge 101 80 mm dia 102 100 mm dia 103 125 mm dia 104 150 mm dia 105 Disposal of surplus earth includingmoorum/stone bolder /building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 106 Boundary wallat zone -3 (chhui khadan) Rcc column based boundary wall as per design 30x50 m BOUNDARY WALL Construction of Boundry wall around campus as per unit estimate with RCC Columns @ 3.0m c/c distance with plinth beam and brick work including supply of all Materials, Labour, Tools and Plants etc. complete., as per departmental type drawing.Construction of2.0 meter high compound wall from formation level of campus,comprising of 230mmx230mm RCC Columns @ 3.0 m c/c distance with 230 mm thick beam at plinth and top, brick work of 230 mm thick in 1:4 and 12 MM THICK 1:4 cement plaster over all surface of wall , two coat of Exterior emulsion paint of approved reputed make over one coat of primer and even surface preparation by applying 2-3 layer of approved reputed make Puttyas perdesign approved by engineer in Charge, including supply of all material, labour, T& P etc complete. 107 3.60 m wide mild steel gate with rcc columns with 1.0 m wicket gate 108 earth filingincludingmoorum/stone bolder /building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 109 Provide all materials, labour and T&P to construct single roomed staff quarter as per type design and quantities of unit estimate all complete , including common stair case and other miscellaneous works. The plinth area of each staff quarter is 57.706 sqm.Detailed Survey, Design& Drawing, Construction of Residential Building based Office Building on R.C.C frame structure at different location finished with all respect, flooring made up with vitrified Tile/ Kota stone , Flush door shutter , glazed window cum ventilation including mosquito proof shutter, waterproofing at roof , anti-skid tile at toilet / bathroom / kitchen , water supply and sanitary work & electrification with all fixture, painting with 3 coat apex at exterior surface and emulsion at interiorsurface including2 coat Birla white puttyofbuilding, apron around building, appropriate size of septic tank and soak pit, including supply of all material, labour, T&P complete as per the direction of the engineer in charge 110 Plinth area of building 57.706 Sqm 111 Re-instatement of following type of road surfaces after laying of pipe line and house connection work including supply of all materials, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movemen 112 Bitumen roadTYPE AConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-GSB G-1 (One coat) (90-40 mm) = 12.5 cmG -2 (one coat) (45-63 mm) = 7.5 cmG - 3 (one coat) (22.5 - 53 mm) = 7.5 cmBM (One coat)= 7.5 cmSDBC (One coat)= 2.5 cm 113 TYPE BConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-Bitumen Road (SDBC + Tack coat)SDBC (One coat)= 2.5 cmTack coat with bituminous emulsion (MS)= 0.25 kg/sqm(30% consider for over dismantling of existing road) 114 Cement Concrete Road(100mm Thick PCC 1:4:8 and 100mm Thick CC 1:2:4) 115 C.C. Interlocking Tiles Road Type AConstruction of 80 mm tihck C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm)Sand= 50 mm thick local sand lair for preparation of surfaceTiles = 30% new + 70% old 116 E and M Work 117 PUMPING PLANT AND ACCESSORIES FOR EXISTING INTAKE WELL ( ZONE-1) KHANDI (2.5 MLD) 118 Supply of Vertical type self-oil lubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.14mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 119 2050LPM, 25.00 HP, 37m Head 120 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm bend, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 121 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 122 Valve actuator of size 150mm for pumps and common header 123 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 124 150 mm Dia 125 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 126 Electromagnetic flow meter of size 150mm for common header 127 ELECTRICAL ITEMS:- 128 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 129 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 130 CE/UL Certified level transmitter for Intake well :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 131 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 132 CE/UL Certified Pressure transmitter for pumps 133 CE/UL Certified Pressure transmitter forCommon Header 134 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 135 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 136 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 137 Cable trench Chequerred plate 138 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 139 Internal & External electrification of pumping station. 140 PUMPING PLANT AND ACCESSORIES FOR EXISTING INTAKE WELL ( ZONE-2)FOR (3.20 MLD+3.50 MLD) 141 Supply of Vertical type self-oil lubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.14mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 142 2500LPM, 30.00 HP, 37m Head 143 MAIN PIPING AND VALVES :-Supply of 200mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 250mm common Header upto 1 m. outsidethe pump house along with 250 x 200 x 250 mm A/F Tee,250 mm bend, 250 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 144 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 145 Valve actuator of size 200mm for pumps 146 Valve actuator of size 250mm for common header 147 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 148 200 mm Dia for pumps 149 250 mm Dia for common header 150 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 151 Electromagnetic flow meter of size 250mm for common header 152 ELECTRICAL ITEMS:- 153 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 154 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION250A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 155 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 156 CE/UL Certified Pressure transmitter forpumps 157 CE/UL Certified Pressure transmitter forCommon Header 158 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 159 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 160 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 161 RENNOVATION OF EXISTING 160 KVA SUB STATION AT INTAKEWELL 162 Supplying of indoor type floor mounted metal clad, 11 KV VCB panel with 1No. VCBs, totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and auto/manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 100 KVa, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 1600Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 11 KV cable (cable entry from *bottom/ top/side) end termination with heat shrinkable jointing material etc. as required. (Note- Cost of end termination not included in this item)(a) Incoming – ½* No 800Amp. VCB(b) 1* No. – 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burder with 1 No. Voltmeter (0-15KV), analog/digital* type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer.(c) 1* No. – (0-100 A) dual scale Ammeter, analog/digital* type, selector switches for ammeters.(d) 1* No. – Microprocessor based numerical relay with O/L, E/F and S/C protection.(e)1* No. – Set of dual core dual ratio 3 CTs 300/150/5/5 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection.(a) Outgoing – 2Nos. 800Amp. VCB(b) 2Nos. – (0-100 A) Ammeters, dual scale analog/digital* type & selector switches for Ammeters.(c) 2 Nos. – Microprocessor based numerical relays with O/L, E/F & S/C protections.(d) 2 Nos. – Setofdualcoredualratio3CTs 100/ 50/5/5 A of 15 VA burden and accuracy Class-1.0 for metering and class 5P10 for protection.1. Supply of power pack 24 volts complete with battery and charging device. 163 Supply of 50 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer. 164 Supplying of 160KVA, 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.5% & -7.5%, having cable end boxes on HV side suitable for 3x150sqmm XLPE cable of 33 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site. 165 Supplying of cubicall type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for framework and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630Amp capacity extensible type TPN aluminium alloy bus bars of hight conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth barof size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from mainbus bar to switch gears with required size of Al. bus bars and control wiring with 50sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-(I) Incoming : 2 Nos.. 630 Amps horizontal drawout type air circui+B12t breaker of fault breaking capacity 50 KA (Ics=Icu upto433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/ OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each ACB.(a) Independent manual spring closing mechanism- 1 No.B10(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Analog 96 mm square flush pattern /Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/ MCBs-1 set.(d) Analog 96 mm. square flush pattern/ Digital* type Ammeter (0-630Amp), with selector switch and one set of 3 nos. CT’s of ratio10/5A Class I accuracy and 15 VA burden- 1set. (e) 3 Nos. Phase indication LED lamps with2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C.(II) Bus Couplers :1Nos. 630Amps drawout type, air circuit breakers offault breaking capacity 50 KA (Ics=Icu upto433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 as amended upto date complete with following accessories for each ACB:(a) Independent manual spring closing mechanism- 1 No.(b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse test terminal block, fuses, circuits contactors for positive electrical interlocking of breakers, etc. as required- 1 set.(III) Bus Bars :TPN aluminium bus bars of minimum of 630Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. 166 (IV) Interlocking :Electrical through advance contacts in ACB’s (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :(a) 1Nos. 630Amp 4 Pole ACB (Ics = kA upto 433 V)/SFU with HRC fuse (BC : 80 kA)(b) CT’s of ratio 10/5Amps 4Nos.4Set (1 set of 2 Nos.)(c) Analog 96 mmsq/Digital* type ammeter (0-100Amp) with selector switch set. 167 Supply and laying of 650/1100 volt grade 185 sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.Tpanel and from outgoing panel to distribution panel (1x3½x185 sq mm) 168 Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules. 169 Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect. 170 Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable 171 Supply and making of outdoor cable end termination joint kit of size 240 sq mm 3 core for 11 KV H.T. XLPE cable 172 Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works. 173 NOC from Electrical safety department for all field installations such as pumping plants, substation etc.( 11KV Power connection is already available at site. 174 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT WTP ( EXISTING 125KL/20 M ) 175 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 176 1845 LPM, 25.00 HP, 32m Head 177 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 178 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 179 Valve actuator of size 150mm for pumps 180 Valve actuator of size 150mm for common header 181 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 182 150 mm Dia for pumps 183 150 mm Dia for common header 184 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 185 Electromagnetic flow meter of size 150mm for common header 186 Electromagnetic flow meter of size 250mm at CWR Inlet 187 ELECTRICAL ITEMS:- 188 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 189 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 190 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 191 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 192 CE/UL Certified Pressure transmitter for pumps 193 CE/UL Certified Pressure transmitter forCommon Header. 194 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 195 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 196 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 197 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 198 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 199 Internal & External electrification of CWR 200 PUMPING PLANT AND ACCESSORIES FROM CWR TO CWR HILLOCK ( EXISTING 850 KL) 201 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 202 1845 LPM, 20.00 HP, 22m Head 203 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 300mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 204 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 205 Valve actuator of size 150mm for pumps 206 Valve actuator of size 150mm for common header 207 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 208 150 mm Dia for pumps 209 150 mm Dia for common header 210 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 211 Electromagnetic flow meter of size 150mm for common header 212 Electromagnetic flow meter of size 250mm at CWR Inlet 213 ELECTRICAL ITEMS:- 214 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 215 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION100A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION63 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 216 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 217 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 218 CE/UL Certified Pressure transmitter for pumps 219 CE/UL Certified Pressure transmitter forCommon Header. 220 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 221 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 222 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 223 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 224 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 225 Internal & External electrification of CWR 226 PUMPING PLANT AND ACCESSORIES FROM CWR WTP TO OHT 350 KL / 22 M 227 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 228 1680LPM, 30.00 HP, 44m Head 229 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outsidethe pump house along with 150 x 200 x 150 mm A/F Tee,200 mm duckfoot bend, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 230 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 231 Valve actuator of size 150mm for pumps 232 Valve actuator of size 200mm for common header 233 Valve actuator of size 300mm at OHT Outlet 234 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 235 150 mm Dia for pumps 236 200 mm Dia for common header 237 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 238 Electromagnetic flow meter of size 200mm for common header 239 Electromagnetic flow meter of size 300mm at CWR Inlet 240 Electromagnetic flow meter of size 300mm at OHT Outlet 241 ELECTRICAL ITEMS:- 242 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 243 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION250A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 244 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 245 CE/UL Certified level transmitter for CWR 246 CE/UL Certified level transmitter for OHT 247 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 248 CE/UL Certified Pressure transmitter for pumps 249 CE/UL Certified Pressure transmitter forCommon Header, OHT outlet etc. 250 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 251 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 252 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 253 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 254 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 255 Internal & External electrification of Pump house 256 PUMPING PLANT AND ACCESSORIES FROM CWR WTP TO EXISTING OHT 1100 KL / 17 M 257 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 258 1680LPM, 25.00 HP, 34m Head 259 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outsidethe pump house along with 150 x 200 x 150 mm A/F Tee,200 mm duckfoot bend, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 260 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 261 Valve actuator of size 150mm for pumps 262 Valve actuator of size 200mm for common header 263 Valve actuator of size 400mm at OHT Outlet 264 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 265 150 mm Dia for pumps 266 200 mm Dia for common header 267 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 268 Electromagnetic flow meter of size 200mm for common header 269 Electromagnetic flow meter of size 300mm at CWR Inlet 270 Electromagnetic flow meter of size 400mm at OHT Outlet 271 ELECTRICAL ITEMS:- 272 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 273 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION200A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 274 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 275 CE/UL Certified level transmitter for CWR 276 CE/UL Certified level transmitter for OHT 277 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 278 CE/UL Certified Pressure transmitter for pumps 279 CE/UL Certified Pressure transmitter forCommon Header, OHT outlet etc. 280 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 281 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 282 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 283 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 284 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 285 Internal & External electrification of Pump house 286 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT CHUIKHADAN ( 450KL / 22M ) 287 Supply of Vertical type self-waterlubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.06mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 288 1860LPM, 30 HP, 40m Head 289 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 290 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 291 Valve actuator of size 150mm for pumps 292 Valve actuator of size 150mm for common header 293 Valve actuator of size 300mm at OHT outlet 294 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 295 150 mm Dia for pumps 296 150 mm Dia for common header 297 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 298 Electromagnetic flow meter of size 150mm for common header 299 Electromagnetic flow meter of size 300mm at CWR Inlet 300 Electromagnetic flow meter of size 300mm at OHT outlet 301 ELECTRICAL ITEMS:- 302 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 303 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 304 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 305 CE/UL Certified level transmitter for CWR 306 CE/UL Certified level transmitter for OHT 307 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 308 CE/UL Certified Pressure transmitter for pumps 309 CE/UL Certified Pressure transmitter forCommon Header. 310 CE/UL Certified Pressure transmitter for OHT outlet 311 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 312 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 313 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 314 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 315 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 316 Internal & External electrification of CWR 317 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT KANSHIRAM COLONY (EXISTING) 318 Supply of Vertical type self-waterlubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.06mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 319 700LPM, 12.5 HP, 35m Head 320 MAIN PIPING AND VALVES :-Supply of 100mm Main piping & valves complete of suitable size and quantity required for delivery side and 100mm common Header upto 1 m. outsidethe pump house along with 100 x 100 x 100 mm A/F Tee,100 mm bend, Enlargers, 100 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 321 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 322 Valve actuator of size 100mm for pumps 323 Valve actuator of size 100mm for common header 324 Valve actuator of size 250mm at OHT outlet 325 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 326 100 mm Dia for pumps 327 100 mm Dia for common header 328 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 329 Electromagnetic flow meter of size 100mm for common header 330 Electromagnetic flow meter of size 250mm at CWR Inlet 331 Electromagnetic flow meter of size 250mm at OHT outlet 332 ELECTRICAL ITEMS:- 333 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 10 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 334 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION100A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION40 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 335 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 336 CE/UL Certified level transmitter for CWR 337 CE/UL Certified level transmitter for OHT 338 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 339 CE/UL Certified Pressure transmitter for pumps 340 CE/UL Certified Pressure transmitter forCommon Header. 341 CE/UL Certified Pressure transmitter for OHT outlet 342 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 343 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 344 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 345 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 346 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 347 Internal & External electrification of CWR 348 INTERNAL AND EXTERNAL ELECTRIFICATION FOR WTP 349 Internal and External Electrification 350 Outdoor Lighting 351 Supply installation tesling & Commissioning of IS0 certiftedcompany made high mast lighting system (as per PLG 07 of ILP UK technical report no 7 of ILE UK /IS:875 Part-1 - 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal (Octogonal) section, telescopic jointed and welding as per BS 5135 and also provide test certificate for wind tunnel test for High mast fixtures. complete in all respect. 352 12.5 Mtr. HM (in 2 Section) 353 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 Im/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz‡3%, Power Factor >0.95 ,driver Efficiency >85% .THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K + 1355K, Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screenprinting on die cast housing to allow traceability/authenticity. Fixture-shall be IS 10322 Complianced and also provide test Certificate/ report with liable warranty of product/accessories. 354 High Power LED Flood Light 200W 355 Indoor Lighting 356 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with2.5 KV internal/external surge protection B|S certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt ,THD < 10 % , p.f.>0.95,CRI >80 . life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000°K / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing and also provide test certificate of LED Fixtures from NABL. 357 36 W LED light Fixture 2 x 2 with acrylic / prismatic front cover. 358 Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 359 Automation For Intake Well 360 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 361 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 362 CE/UL Certified Intelligent energy meters 363 CE/UL Certified Surge protector for control panel 364 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 365 Cable 366 (i) Complete cabling above 3 Pumps 367 Security Survelliance IP Camera with recorder (optional) 368 Installation, commissioning & testing 369 AUTOMATION FOR CWR-1A 370 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 371 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 372 CE/UL Certified Intelligent energy meters 373 CE/UL Certified Surge protector for control panel 374 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 375 Turbidity Analyzer at CWR 376 PH Analyzer 377 Chlorine Analyzer 378 Cable 379 (i) Complete cabling upto 3 Pumps 380 Security Survelliance IP Camera with recorder (optional) 381 Installation, commissioning & testing 382 AUTOMATION FOR CWR-1B 383 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 384 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 385 CE/UL Certified Intelligent energy meters 386 CE/UL Certified Surge protector for control panel 387 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 388 Turbidity Analyzer at CWR 389 PH Analyzer 390 Chlorine Analyzer 391 Cable 392 (i) Complete cabling upto 3 Pumps 393 Security Survelliance IP Camera with recorder (optional) 394 Installation, commissioning & testing 395 AUTOMATION FOR CWR-2A 396 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 397 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 398 CE/UL Certified Intelligent energy meters 399 CE/UL Certified Surge protector for control panel 400 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 401 Turbidity Analyzer at CWR 402 PH Analyzer 403 Chlorine Analyzer 404 Cable 405 (i) Complete cabling upto 3 Pumps 406 Security Survelliance IP Camera with recorder (optional) 407 Installation, commissioning & testing 408 AUTOMATION FOR CWR-2B 409 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 410 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 411 CE/UL Certified Intelligent energy meters 412 CE/UL Certified Surge protector for control panel 413 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 414 Turbidity Analyzer at CWR 415 PH Analyzer 416 Chlorine Analyzer 417 Cable 418 (i) Complete cabling upto 3 Pumps 419 Security Survelliance IP Camera with recorder (optional) 420 Installation, commissioning & testing 421 AUTOMATION FOR CWR-2C 422 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 423 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 424 CE/UL Certified Intelligent energy meters 425 CE/UL Certified Surge protector for control panel 426 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 427 Turbidity Analyzer at CWR 428 PH Analyzer 429 Chlorine Analyzer 430 Cable 431 (i) Complete cabling upto 3 Pumps 432 Security Survelliance IP Camera with recorder (optional) 433 Installation, commissioning & testing 434 AUTOMATION FOR CWR-2D 435 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 436 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 437 CE/UL Certified Intelligent energy meters 438 CE/UL Certified Surge protector for control panel 439 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 440 Turbidity Analyzer at CWR 441 PH Analyzer 442 Chlorine Analyzer 443 Cable 444 (i) Complete cabling upto 3 Pumps 445 Security Survelliance IP Camera with recorder (optional) 446 Installation, commissioning & testing 447 Local Control Station at WTP 448 CE/UL & BIS Certified industrial grade LED Monitor with latest configuration as per specification 449 Desktop / PC with i5/i7 processor for as per technical bid documents 450 CE/UL Certified 3 KVA UPS with batteries as per technical bid documents 451 Full development version of required TAGS SCADA Software with customization of software for LCS as per requirement as per spec. mentioned in technical bid documents. 452 CE/UL certified local control room PLC with redundant CPU & power supply at LCS in IP 54 enclouseras per spec. mentioned in technical bid documents. 453 GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & received data & gather from remote sites to control station, all accessories included signal enhancer anternna along with running expenses till DLP 454 CE/UL Certified firewall for network protection 455 SURGE PROTECTOR FOR ETHERNET communication protection. 456 CE/UL certified industrial grade Ethernet Swtich 457 Cannon/HP or equivalent Laser printer 1018 or equivalent 458 Security Survillance IP Camera with recorder (Optional) 459 Installation, Commissioning & testing including required furniture, A/C etc. 460 Trial & Run 461 03 Months trial & run

Key Value

Document Fees
INR 23600 /-
EMD
INR 2082000.0 /-
Tender Value
INR 20.81 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail