}

Tender For Special Repair To Bldg No P-824, P-833 And P-835 (Mt Shed) Of 343 Fd Regt And Provn Of Storage Accn For Age B/R-Ii Under Age B/R-Ii At Itarana Alwar, alwar-Rajasthan

Military Engineer Services has published Tender For Special Repair To Bldg No P-824, P-833 And P-835 (Mt Shed) Of 343 Fd Regt And Provn Of Storage Accn For Age B/R-Ii Under Age B/R-Ii At Itarana Alwar. Submission Date for this Tender is 14-10-2024. Building Work Tenders in alwar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

45232372
Corrigendum : Tender For Special Repair To Bldg No P-824, P-833 And P-835 (Mt Shed) Of 343 Fd Regt And Provn Of Storage Accn For Age B/R-Ii Under Age B/R-Ii At Itarana Alwar
Open Tender
Indian
Rajasthan
Alwar
14-10-2024

Tender Details

special Repair To Bldg No P-824, P-833 And P-835 (Mt Shed) Of 343 Fd Regt And Provn Of Storage Accn For Age B/R-Ii Under Age B/R-Ii At Itarana Alwar-- 1 Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key, scrubbing down with water etc all as directed. 2 M&L rendering 10mm thick in CM (1:6) on fair faces of brick/stone masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified. 3 M&L 15 mm thick rendering on fair faces of brick/stone masonary in CM (1:4) finished with even and smooth without using extra cement complete all as specified and directed. 4 M&L rendering 5mm thick in CM (1:3) on concrete surfaces in ceiling, soffits and the likes; finished even & smooth without using extra cement complete all as specified. 5 M&L preparing new/old plastered surfaces & applying two coats of exterior emulsion (Apex) over a coat of primer complete all as specified and directed 6 M&L preparing newly plastered surfaces & applying three coat of white wash on ceiling complete all as specified and dircted 7 Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc. 15 cm thickness (below or above ground level) complete all as specified and as directed. 8 M&L 8-10mm thick vitrifiedtiles(dark shade / double charged / ultra charged), (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm as in vertical surfaces over with and including 10 mm thick rendering in CM (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and directed. 9 M&L 8-10mm thick vitrifiedtiles(dark shade / double charged / ultra charged), (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm as in floors laid over with and including 15 mm thick screed bedin CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and directed. 10 M&L 75 mm thick PCC(1:3:6), Type C1 (using 20mm graded stone aggregate ) as in plinth protection finished fair and even, path laid in panel surface finished even and fair using extra cement and joints of panel shall be filled by bitumenous primer complete all as specified & directed. 11 S&FPre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etccomplete all as specified & directed 12 S&FPre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etccomplete all as specified & directed 13 M&L 75 mm thick PCC (1:4:8), Type D-2 (using 40 mm graded stone aggregate)as in sub base of floor/pavings complete all as specified and directed. 14 M&L 25 mm thick PCC (1:2:4), Type B-0 (using 12.50mm graded stone aggregate)as in floors/levelling course complete all as specified and directed. 15 M&L 100 mm thick PCC (1:2:4), Type B-1 (using 20mm graded stone aggregate)as in floors/pavings complete all as specified and directed. 16 M&L PCC (1:4:8), Type D-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified & directed 17 Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonryand removal complete all as specified & directed 18 S&F factory made 30mm thick flush shutter, solid core construction, with block board core and plywood face panels, both face covered with deco rative face veneer with lipping/frame to match commercial typeon both sides with self closing circular knob for locking arrangemenall as specified and directed. 19 S&F factory made 2nd class glazed and skelton door shutter made out of stiles & rails of 30mm thick 2nd class hard wood, klin seasoned and chemically pressure treated & open reabted and prepared to receive glass/gauge etc (without sash bars), edges of framing plain,chamfered of rounded, fitted with and mitred beads for securing glass etc compelte, the SIze of members of shutter shall be as per IS-1003.The shutter shall be fitted to the chowkhats as directed by Engr-in-Charge. 20 S&FSS sliding door bolt with hasp,staple (bolt type) 300mm longnot less than 12mm dia with and incl minimum of 06 bolts and nuts, 4 on plate and 2 on staple and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, plate and fixed all as specified. 21 S&F 150 mm long SS barrel tower bolts of extruded section and fixed complete all as specified & directed 22 S&FSS handles 150mm size fabricated type anodized ISI marked complete all as specified & directed 23 S&F MS Retractable Hinge fixed to wooden or steel frames with Screws/welding as required at site complete all as specified & directed. Make : Hitachi or equivalent as approved by GE 24 S&F exctruted aluminum alloy with galavanisied mild steel hing pin Butt hinges 100mm long 25 S&F 140 mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring,with vulcanised rubber piece fixed in floor as directed 26 Preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed 27 M&L framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steelsheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete & making good the floor in PCC (1:2:4) type B-0 to match the existing floor Fe-410 (Gde-E250 quality A). 28 Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed 29 Preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as directed 30 S&F anodized aluminium frame and other sections for doors, windows, ventilators, partitions, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed. 31 S&F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) with and including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed. 32 S&F Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples complete all as specified. 33 S&F 5 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 Sqm in each pane complete all as specified and directed. 34 M&L 15mm thick screed bed on fair faces of concrete/brick surfaces in CM(1:4) with water proofing compound @ 3% by weight of cementeven and smooth in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane finished complete all as specifiedNote : Water proofing compound shall be measured and paid separately here-in-after. 35 M&L water proofing treatment to RCC roof slab including parapet comprising of following course of treatement/specified from bottom to top (a)Applying Bituminous primer 85/25 @ 0.40 Ltr per sqm over plastered surfaces of roof including parapet surfaces. (b)Over the priming coat laying one layer APP based polymeric membrane of approved manufacturer, 3 mm thick weight not less 3.6 Kgs/Sqm and upper side of membrane thermally insulated with white mineral gravel finish , unifirmly embeded during manufacturing process shall only be used, it shall be laid by torch application, side overlap should be 75mm and end shall be 100mm.For parapets, membrane shall be taken to a height of minimum 60cm and then inserted inside parapet in groove.The same shall be finished by a membrane flashing complete all as specified and directed. 36 Supply only Integral water proofing compoundcomplete all as specified and directed. 37 M&L colouredmachine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80mm thickness M40 grade and grey cement and pigment for berms laid over with and including 25 mm thick layer of sand cushion complete all as specified and directed. 38 Excavation in trenches n.exc. 1.5 Mtr wide and n.exc. 1.5 Mtr in depth for foundation and getting out in soft/loose soil complete all as specified and directed. 39 Surface dressing n exc 15 cm deep and getting out in soft/loose soil complete all as specified and directed. 40 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. 41 Removing excavated material, n.exc 50 Mtr and depositing where directed at a level n.exc 1.5 Mtr above the starting pointcomplete all as specified and directed. 42 M&L brick work with fly ash brick straight or curved on plan exc 6m mean radiusbuilt in CM (1:6) complete all as specified and as directed. 43 M&L RCC (1:2:4)type B1 (using 20mm graded stone aggregate) as in foundation including footing, plinth beam, base for column, etc complete all as specified anddirected. 44 M&L RCC (1:2:4)type B1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and strutsetc complete all as specified and directed. 45 M&L RCC (1:2:4)type B1 (using 20mm graded stone aggregate) as inbeams, cantilevers, bressummers and lintels over 1.5m span complete all as specified anddirected. 46 M&L RCC (1:2:4)type B1 (using 20mm graded stone aggregate) as inslabs sopported on walls, beams and columns in floors, roofsetc complete all as specified anddirected. 47 M&L RCC (1:2:4)type B1 (using 20mm graded stone aggregate) as inchajjas and the likes; complete all as specified anddirected. 48 M&L mild steel (TMT bar)10mm dia and over cut to length bent to shape reqd, incl, cranking benching spirally for hooping for columns hooking ends and bending with and including MS wire annealed wire not less than 0.9 mm dia. 49 M&L mild steel (TMT bar) 5mm to 10mm dia and over cut to length bent to shape reqd, incl, cranking benching spirally for hooping for columns hooking ends and bending with and including MS wire annealed wire not less than 0.9 mm dia as in stirrups, spacers, binders etc. 50 M&L Formwork to edges of concrete flats n.exc. 12cm wide complete all as specified and as directed 51 M&L form work to side of concrete foundation , footing, bases of columns, raft and raft beams, sides and soffits (If any) of foundation and plinth beams and similar work, vertical or to batter complete all as specified and as directed 52 M&L form work to side of pillar, posts, struts, piers, columnsetc complete all as specified and as directed 53 M&L form work to sides and soffits of floor or roof beam, beam haunching, griders, bressummers lintels, cantilevers, shelves including supprots, overhangs etc also splays between floors and beams etc complete all as specified and as directed 54 M&L form workas in suspended slab, such as roof slabs, floor slabs, landings and similar work, not exceeding 20mm thick(Horizonal or sloping) complete all as specified and as directed 55 M&L form workto cullaah hoods, chajjas, throughs and similar items including edges complete all as specified and as directed 56 M&L structural steel works as in rafter, purlin, post made of the MS hollow section, square/rectangular ,roof trusses (framed), Fe 410 -W (GdeE- 250) quality-A including distance pieces, cleats etc including one shop coat of primer complete all as specified and directed 57 Treating the bottom and side of excavation at the rate 5 ltr/sqm emulsion (ATT) of surface area complete all as specified and as directed. 58 Treating the backfil in contact with foundation at the rate of 7.5ltr/sqm (ATT) emulsion of surface areacomplete all as specified and as directed. 59 M&L treating the bottom surface of floorat the rate 5 ltr/sqm emulsion (ATT) of surface area complete all as specified and as directed. 60 M&L treating the soil under plinth protection at the rate of 5 Ltr/Sqm emulsiom (ATT) of surface area complete all as specified and as directed. 61 Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges in large patches as in roof covering complete all as specified and as directed. 62 Dismantling structural steel work including doors, gates but excluding framed truss etc. 63 M&L Hardcore of gauge (broken stones)n.exc 63mm deposited spread levelled in layers n.exc 15 cm thick watered and rammed to a true surface complete all as specified and directed. 64 S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 directed 65 Forming 12mm thick expansion joints filled with pre-formed bitumenous filler and top 30mm primed and sealed with sealing compound grade A for 100 mm thick PCC floor complete all as specified and directed. 66 Forming constructionjoints 65mm deep & 10mm widefilled with pr-formed bitumenous filler and top 30mm primed and sealed with sealing compound grade Acomplete all as specified and directed. 67 Taking down carefully copper/Aluminium point wiring for light/fan/socket/light fitting/power point and taking down of teak wood batten / PVC casing caping/PVC conduit/steel conduitand making good disturbed surfacesof walls/ceilings /floors etc with and including dismantling of fittings complete all as specified and directed. 68 M&L point wiring complete with 1.5 Sqmm single core multistranded copper conductor fire resistant low smoke (FRLS) PVC insulated and unsheathed cable 1100 Volts grade confirming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20 mm external dia) but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling including 1.5 mm FRLS PVC insulated unsheathed copper earth wire including sunken type pressed steel terminal boxes electro plated of suitable size with bakellite white/coloured top sheet cover 3.0 mm thick for one light point controlled by one way switch all as specified & directed. 69 All as per serial item No. 68.00 here-in-before but for one ceiling fan/exhaust fan point controlled by one switch and regulator 70 All as per serial item No. 68.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board. 71 All as per serial item No. 68.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board. 72 All as per serial item No. 68.00 here-in-before but for one light point controlled by two way switch 73 All as per serial item No. 68.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour. 74 S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts. 75 S&F switch piano, flush type, single pole, two way, 5/6 Amp, 230 Volts. 76 S&F switch piano, flush type, single pole, one way, 15 Amp, 230 Volts. 77 S&F socket outlet, 3 pin (with 2 pin outlet also), 5/6 Amps, flush type, 240 Volts, ISI marked. 78 S&F switch socket combination outlet, 2 in 1, 3 pin, 5/15 Amps flush type multipurpose with fuse & neon indicator ISI marked. 79 S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified. 80 S&F stepped type electronic fan regulator, flush and connecting up, SIS marked, 240 Volts. 81 S&F decorative ultra slim liner LED lighting fixture with extended poly carbonate environmental friendly, energy efficient suitable for 20W with LED tube of model E-LITE LED pride and connecting up, complete all as specified and directed.Make : Havells cat part No. LHEXBHP71N1W018 or equivalent of philips/Crompton Greaves/ bajaj/Wipro/GE 82 S&F LED type street-DRACO SERIES light luminaire 25 watt 230 V 50 Hz including all necessary fitting accessories and LED complete all as directed. Make: C&S Cat Part no. LTESS20WLED or equvalent Crompton Greaves /Wipro 83 S&F lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified. 84 S&F LED Bulb energy saving 10/11 W complete all as specified and directed Make :- Havells/Crompton/Syska 85 S&F sheet metal enclosuresdouble door type suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts. 86 S&F sheet metal enclosuresdouble door type suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 4 way, 240 Volts. 87 S&F MCB 63 Amp, three pole & neutral, 415 Volt complete all as specified & directed. 88 S&F MCB 32/40 Amp, single pole & neutral,240 Volt complete all as specified & directed. 89 S&F MCB 6-40 Amp, single pole240 Volt complete all as specified & directed. 90 S&F Sheet metal enclousure double door type ,suitable for fixing TPN with 200 Amps rated bus bar ,vertical DB 4 way TPN 415 Volts complete all as specified & directed. 91 Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 Sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed.Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid separately under relevant items. 92 Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 Sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed.Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid separately under relevant items. 93 M&L brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed. 94 M&L dry sand and punning for cushioning to under ground cable all as directed.Note :- For the purpose of payment only punned thickness shall be measured. 95 M&L 40mm dia GI pipe, Light grade for protection of LT cable fixed to walls/ poles/road crossing including clamps complete all as specified and directed. 96 S&F exhaust fan ACsingle phase 230/240 Volts of size 300 mm sweep with louver with and including cutting holes in brick/stone wall of required size carefully and making good the disturbed surfaces to match with the existing in CM (1:3) complete all as specified and directed. 97 S&F ceiling fan complete with electronic type regulator and accessories, 1200mm sweep, 230 Volts, BEE 5 Star rated with brushless direct current motor (BLDC) 98 S&F sub main wiring on and includingpassing through PVC conduit pipe 1100 Volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm and continuous earth with PVC flexible cable copper conductorunsheathed multistranded single core of size 6 sqmm of green colour confirming to IS 694/1990 with and including taking down existing unserviceable sub main wiring. (Note:Two runs of cable with one run of earth wire and one run of PVC Coundit shouldmeasured as one length) 99 M&L earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers,PCCchamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified &directed. 100 S&F LED flood light 70 watt, 230 VAC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 04-10-2024 Corrigendum No 2 Date 14-10-2024
2 27-09-2024 Corrigendum No 01 BOQ 05-10-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80100.0 /-
Tender Value
INR 40.03 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail