}

Tender For Electrical Upgradation Of Upsida Industrial Area, Partapur, Meerut (Part-1) Under Aiim-2, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface, meerut-Uttar Pradesh

Government Departments has published Tender For Electrical Upgradation Of Upsida Industrial Area, Partapur, Meerut (Part-1) Under Aiim-2, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface. Submission Date for this Tender is 14-10-2024. Civil Work Tenders in meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45229097
Corrigendum : Tender For Electrical Upgradation Of Upsida Industrial Area, Partapur, Meerut (Part-1) Under Aiim-2, 1 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface
Open Tender
Indian
Uttar Pradesh
Meerut
14-10-2024

Tender Details

Tender For Electrical Upgradation Of Upsida Industrial Area, Partapur, Meerut (Part-1) Under Aiim-2, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 3 Wiring for twin control light pointwith 1.5 Sq.mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(as per UPPWD approved make list) 4 Wiringforlight /powerplugwith 2 x 4 Sq.mm. FRLS PVC insulated, copper conductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no. 4 Sq.mm FRLS PVC insulated copper conductor single core cable forloopearthing as required.(as per UPPWD approved make list) 5 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(as per UPPWD approved make list) 6 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (as per UPPWD approved make list) 7 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 8 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 9 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 x 16 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 10 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 11 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 16 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 12 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (as per UPPWD approved make list) 13 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (as per UPPWD approved make list) 14 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (as per UPPWD approved make list) 15 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150 mm X 150 mm X 60 mm deep (as per UPPWD approved make list) 16 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 150mm x 100mm deep (as per UPPWD approved make list) 17 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 250mm x 300mm x 100mm deep (as per UPPWD approved make list) 18 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 19 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 20 Supply and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(as per UPPWD approved make list) 21 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(as per UPPWD approved make list) 22 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.(as per UPPWD approved make list) 23 Supplying and fixing brass batten/ angle holder including connection etc. as required.(as per UPPWD approved make list) 24 Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (as per UPPWD approved make list) 25 Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, C curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.. single pole (as per UPPWD approved make list) 26 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. (as per UPPWD approved make list) 27 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way, Double door(as per UPPWD approved make list) 28 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 8 way, Double door(as per UPPWD approved make list) 29 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 8 way, Double door (as per UPPWD approved make list) 30 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 16 way, Double door (as per UPPWD approved make list) 31 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps (as per UPPWD approved make list) 32 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (as per UPPWD approved make list) 33 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required(as per UPPWD approved make list) 34 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 35 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (as per UPPWD approved make list) 36 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 37 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 38 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (as per UPPWD approved make list) 39 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (as per UPPWD approved make list) 40 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. (as per UPPWD approved make list) 41 Supply,installation, testing andcommissioning of2ft 10W LED Batten delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture(Make-Bajaj, Philips, Wipro, Crompton) 42 Supply,installation, testing andcommissioning of 4ft 20W LED Batten delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.95 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture(Make-Bajaj, Philips, Wipro, Crompton) 43 Supply,installation, testing andcommissioning of18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white. IP20 , Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer (Make-Bajaj, Philips, Wipro, Crompton) 44 Supply,installation, testing andcommissioning of 10W Bulkhead delivering minimum system lumen of 1000 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK08along with Opal Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 140 to 280V along with THD ≤ 10% & PF ≥ 0.95. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton). 45 Supply,installation, testing andcommissioning of Aviation obstruction light with LED lamp, toughened clear glass, with all accessories as per standard item with all accessories.(Make-Bajaj, Philips, Wipro, Crompton) 46 Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame, Louvers shutters and other accessories etc.complete . 250-300 mm sweep (Heavey Duty)(as per UPPWD approved make list) 47 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(as per UPPWD approved make list) 48 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (as per UPPWD approved make list) 49 Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. . 3 output (1 output per phase) and suitable for three phase supply(as per UPPWD approved make list) 50 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 51 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) (as per UPPWD approved make list) 52 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 53 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 54 Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.. 1 or 2 Module (75mmX75mm) (as per UPPWD approved make list) 55 Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.. one run (as per UPPWD approved make list) 56 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required(as per UPPWD approved make list) 57 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. Telephone socket outlet (as per UPPWD approved make list) 58 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. TV antenna socket outlet (as per UPPWD approved make list) 59 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. iNCOMER100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh, Acc class 1.100/5A 5VA class 1 resin cast CT - 1 setOutgoing.63 A FP 10 kA MCB - 8 nos. 40 A DP 10 kA MCB - 4 nos. (as per UPPWD approved make list) 60 Supply, Installation, Testing & Commissioning of Streetlighting panel, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free standing, floor mounting, dust and vermin proof, powder coated, outdoor type, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket, IS 8623 etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification.Incomer63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz, complete with handle assembly having door interlock - 1 no. Busbar1 Set of 100 A TPN busbars of high conductivity electrolytic quality Aluminium alloy. Instruments2A, C curve SP MCB - 3 nosRYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.63/5A 5VA class 1 resin cast CT - 1 setOutgoing.40A TP+NL C curve MCB -8 nos.16A SP+NL C curve MCB -3 nos.Necessary space provision and control wiring for satisfactory operation of Astronimical time switch for automatic switching ON & OFF of street lights.(as per UPPWD approved make list) 61 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 2 core (as per UPPWD approved make list) 62 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 4 core (as per UPPWD approved make list) 63 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 50 sqmm 3 1/2 core (as per UPPWD approved make list) 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) (as per UPPWD approved make list) 65 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (as per UPPWD approved make list) 66 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. 3.5 x 50 Sq mm (35 mm) (as per UPPWD approved make list) 67 Supply and installing following size of perforated hot dipped GI cable trays(galvanisation thickness not less than 50 microns) with perforations not more that 17.5% in convenient sections, jointed with connectors, suspended from the ceiling with GI suspenders / fixed to walls with suitable GI clamps, including bolts and nuts, bends, reducers, Tees, cross members etc as required.150 mm width x 50 mm depth x 1.6 mm thickness(as per UPPWD approved make list) 68 SITC of 5/6 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with isolationtransformer,with 26Ahx x 16 nos SMF Batteries for back up, with required cabling for incoming & outgoing connection (as per UPPWD approved make list) 69 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kgcomplete in all respect as per direction of E/I. (as per UPPWD approved make list) 70 S/F of Straight M.S. Channel 125x65 mm (10.7 Kg./M) 3.2 M long as per design for cross area. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 71 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 72 S/Fixing angle iron 50x50x6mm (4.5Kg./M) length as per design for bracing of the D.P. Structure.complete in all respect as per direction of E/I.(as per UPPWD approved make list) 73 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 74 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 75 Supply, Stringing, tensioning, jointing and binding of all sizes of G.I. / G.S. wire on Steel tubular poles. The binding of G.I. / G.S. wore shall be done with the specified size of G.I. wire or as per direction of Engineer-In-Charge on the specified countings on the poles. Weight of G.I. /G.S. Wire is to be determined by measuring taut horizontal distance between centres of two adjacent pole and compounding the weight of wire by using a standard table of weights of G.I. /G.S. wire. 2% extra may be added for sag at the direction of the Engineer-In-Charge. All inclusive of T& P, Men & material for proper completion of works as per direction of Engineer-In Charge of work/site and in street adhrence to Drg and Work No. UPSIDC/ED(as per UPPWD approved make list) 76 Painting of Support and allmountings on it with two/three coats of alluminium paints with an under cost of Red-oxide paint on length of the supports above the ground level or as per direction of Engineer-in-charge of work/site, inclusive of all T& P , Men & material for proper completion of work. B) Pole Above 10M(as per UPPWD approved make list) 77 Supply and fixing danger board fabricated from 10 No. gauge M.S. Sheet as per I.E. Rules complete in all respect. (as per UPPWD approved make list) 78 Supply & fixing of anticlimbing device fabricated from G.I. flat of 25 mm X 6mm size in a shape of ring of the polesize , having G.I. flat pointed fins of length 225mm in 8 Nos. and also barbed wire in 200mm length above the said ring, including material labour and T&P required for Proper completion of the work as per specification.(as per UPPWD approved make list) 79 S/F of 33KV with 11KVA 4Nos. Set B&S type strain disc insulators 120KN E&M strength complete in all respects as per direction of E/I. Busbar in two section (Jaishree,Bhel,RR,WS, Rama make) (as per UPPWD approved make list) 80 S/F of 33KV pin insulator with pin on main terminal gantry, as per direction of E/I (jaishree,bhel,RR, WS, Rama make) rates as per previous sanctioned estimate job no. ED-1(296) dated 07.11.2023(as per UPPWD approved make list) 81 Supply & Installation of 33 KV F-Bracket with clamp nut & bolt complete in all respect as per direction of E/I.(as per UPPWD approved make list) 82 Supply & grouting of stay rod, complete with all its components specified here-in -under and supply & fixing of stay clamps including all bolts, nuts, washers etc. to the pole along with binding nozzling and requisite tensioning of stay wire of under given size together T&P men & material for proper completion of work as per direction of Engineer- in-charge of work/site and strict adhrerrence to Drawingwork no. UPSIDC/ED/ complete in all respect.(as per UPPWD approved make list) 83 Supply & fixing of G.I. pipe B class for climbing up the cable from ground to overhead line including all accessories, materials, labour and T& P required for proper completion of the work as per specification but excluding cost of clamps. i) 100mm dia (as per UPPWD approved make list) 84 S/F of M.S. Clamp made out of 50x6mm M.S. Flat for securing G.I. pipe with S.T. Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 85 S/F of P.G. clamp suitable for Panther/Dog/Weasel Conductor for jumpering completein all respect as per direction of E/I rates(as per UPPWD approved make list) 86 Supply , Laying , Testing & Commissioning of 3 core standered aluminiumconductor 300 sq.mm 3 core 33 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11KV/33 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. (Grandlay, Gloster, Polycab, Havells, KEI make) 87 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size.(as per UPPWD approved make list) 88 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework.(as per UPPWD approved make list) 89 Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021(as per UPPWD approved make list) 90 Supply and making of 33 KV, 3x300 sq.mm XLPE Cable outdoor heat shrinkable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. (as per UPPWD approved make list) 91 S/F of Straight M.S. Channel 100x50 mm (7.9 Kg./M) 2.24 M long as per design for cross area. complete in all respect as direction of E/I.(as per UPPWD approved make list) 92 Supply & fixing of VShape M.S. Channel 75X 40mm (6.8Kg/M) as per design for cross-arm including all T&P & Men & material for proper completion of work complete in all respect as per direction of E/I.(as per UPPWD approved make list) 93 Supply & fixing 11KV disc & fittings on cross arm/clamp fixed on S.T. poles includingall T& P , men material for completion of Work complete in all respect as direction of E/I.(as per UPPWD approved make list) 94 Supply & fixing 11KV pin with insulator on cross-arms fixed on S.T. Poles including all T&PMen & material for proper completion of work. complete in all respect as direction of E/I.(as per UPPWD approved make list) 95 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 96 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as direction of E/I.(as per UPPWD approved make list) 97 Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting withgrouting as per technical specifications.(as per UPPWD approved make list) 98 Supply, Sagging , tensioning , jointing & binding of specified ACSR Conductor including cost of Al. tape, binding wire & jointing sleeves etc. standard table weight of the conductor shall be taken by measuring span from pole centre to centre and giving and allowance of 3% for sag , jumpers & cut lengths.The rate includes the cost of P.G.Clamps bindng wires, alluminium tape & jointing sleeves if required. All inclusive of T&P , men & materialfor proper completion of the work as per direction of Engineer-in-charge. d) ACSR Dog Conductor(as per UPPWD approved make list) 99 Supply, laying, Testing & Commissioning of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc..185 sq.mm 3 core 11 KV HT XLPE Cable(Grandlay, Gloster, Polycab, Havells, KEI make) 100 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Five ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and4 Nos. outgoing 630Amp VCB) with SCADA compatible.( Make-ABB, Schneider, Siemens, Crompton Greaves) 101 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) four ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 3 Nos. outgoing 630Amp VCB) with SCADA compatible. ( Make-ABB, Schneider, Siemens, Crompton Greaves) 102 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Three ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 2 Nos. outgoing 630Amp VCB) with SCADA compatible.( Make-ABB, Schneider, Siemens, Crompton Greaves) 103 Supply & fixing of welded wire mesh fencing of 5X3X2.4Meter and 2X2.4M gate including excavation base concrete & brick work with back filling etc. complete in all respect. Rates as per sanctioned vide job no. ED-I (83) Dt.25.11.2021(as per UPPWD approved make list) 104 Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paintof approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P.(as per UPPWD approved make list) 105 Lettering with black japan paint of approved brand and manufacturer (11KV भूमिगत केबल )(as per UPPWD approved make list) 106 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 107 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 108 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 109 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect.(as per UPPWD approved make list) 110 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). (as per UPPWD approved make list) 111 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. complete in all respect as direction of E/I. (as per UPPWD approved make list) 112 Digging of depth of 900 mm below ground level over a cushion of 100mm thick five river sand all around on protect with wall bricks on sides and and on top put acrosscomplete in all respect as direction of E/I. (as per UPPWD approved make list) 113 Supply and insatallation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.4 KV Alum. wound as Technical specification of UPPCL complete in all respect as per direction of E/I. (as per UPPWD approved make list) 114 Supply & fixing of 11KV TPMO Set with Polymer Insulator complete in all respect as per direction of E/I.(as per UPPWD approved make list) 115 Supply & fixingof3phase DO Set complete in all respect as per direction of E/I. (as per UPPWD approved make list) 116 Supply & Installation of Top Channel complete in all respect as per direction of E/I. (as per UPPWD approved make list) 117 Supply & Installation of Dropper Channel complete in all respect as per direction of E/I. (as per UPPWD approved make list) 118 Supply & Installation of MS Angle 75x75x6x2028mm complete in all respect as per direction of E/I. (as per UPPWD approved make list) 119 Supply & fixing straight M.S. Channel 100X50mm (7.9Kg./M) 1.15 M long as per design for cross-arm includingall T& P & Men & material for proper completion work.(as per UPPWD approved make list) 120 Supply & Installation of Clamps with Bolt & Nut complete in all respect as per direction of E/I. (as per UPPWD approved make list) 121 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 122 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as per direction of E/I. (as per UPPWD approved make list) 123 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Main LT Panel #1INCOMER: 800 Amp. MCCB-1 NoOUTGOING: 200 Amp.MCCB-3 Nos., 100 Amp.MCCB-1No & 63 Amp.MCCB-1No (as per UPPWD approved make list) 124 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Main LT Panel #1INCOMER: 630 Amp. MCCB-1 NoOUTGOING: 200 Amp. MCCB-2 Nos. 100 Amp-MCCB-1 No& 63 Amp. MCCB-2 Nos.(as per UPPWD approved make list) 125 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.Sub LT Panel Incomer 200 Amp. TPN-1 NoOutgoings 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos.(as per UPPWD approved make list) 126 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only..Incoming100 Amp. TPN-1 NoOutgoing(a) 63 Amp. TNP-2 Nos. (ii) Cat. B. Cubicle Type(as per UPPWD approved make list) 127 Supply, Installation & commissioning of 40A TPN Centralized Group control Monitoring/CCMS street light control Panel having communication technology of GSM/GPRS/3G/4G/5G, real time clock with battery backup, controller power consumption <10 W, operating voltage 140 to 270V AC, built in surge protection 4 kv, External surge protection 40kv , Ingress protection IP55, having self protection from short circuit, over voltage, overload, Trip /events and anti theft alert provision. The cubical of panel painted with anti-corrosive alkali and acid proof powder coated paint suitable for Pole/Wall/ Structure mounting provision complete in all respect. (Including SaaS Charges) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 128 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 10 sq.mm 4 core(Cable laid in Ex. DWC Pipe) (Grandlay, Gloster, Polycab, Havells, KEI make) 129 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.16 sq.mm 4 core (Cable laid in Ex. DWC Pipe) (Grandlay, Gloster, Polycab, Havells, KEI make) 130 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.25 sqmm 3.5 core(Cable laid in Ex. DWC Pipe) (Grandlay, Gloster, Polycab, Havells, KEI make) 131 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.70 sq.mm 3.5core(Grandlay, Gloster, Polycab, Havells, KEI make) 132 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.95 sq.mm 3.5 core (Grandlay, Gloster, Polycab, Havells, KEI make) 133 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 120 sq.mm 3.5 core(Grandlay, Gloster, Polycab, Havells, KEI make) 134 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 240 sq.mm 3.5 core(Grandlay, Gloster, Polycab, Havells, KEI make) 135 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 300 sq.mm 3.5 core(Grandlay, Gloster, Polycab, Havells, KEI make) 136 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 10 sq.mm 4 core (as per UPPWD approved make list) 137 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 16 sq.mm 4 core (as per UPPWD approved make list) 138 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 25 sq.mm 3.5core (as per UPPWD approved make list) 139 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 70 sq.mm 3.5core (as per UPPWD approved make list) 140 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 95 sq.mm 3.5 core (as per UPPWD approved make list) 141 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 120 sq.mm 3.5 core (as per UPPWD approved make list) 142 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 240 sq.mm 3.5 core (as per UPPWD approved make list) 143 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 300 sq.mm 3.5 core (as per UPPWD approved make list) 144 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 10 sq. mm (as per UPPWD approved make list) 145 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 16 sq. mm (as per UPPWD approved make list) 146 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 25 sqmm (as per UPPWD approved make list) 147 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 35 sq. mm (as per UPPWD approved make list) 148 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 50 sq. mm (as per UPPWD approved make list) 149 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 70 sq. mm (as per UPPWD approved make list) 150 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 95 sq. mm (as per UPPWD approved make list) 151 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 120 sq. mm (as per UPPWD approved make list) 152 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 150 sq. mm (as per UPPWD approved make list) 153 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 sq.mm (as per UPPWD approved make list) 154 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 300 sq. mm (as per UPPWD approved make list) 155 Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in charge.(as per UPPWD approved make list) 156 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 160 mm dia (OD-160 mm & ID-135 mm nominal) (as per UPPWD approved make list) 157 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 158 Dismantling of damaged ST Pole which cause to any accident of men & UPSIDA property in industrial area including cost of men and T&P and shifting to store charge. (as per UPPWD approved make list) 159 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. ACSR conductor (old & used) (as per UPPWD approved make list) 160 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge.LT Cable & AB Cable (as per UPPWD approved make list) 161 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. GI Earth wire(old & used) (as per UPPWD approved make list) 162 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. HT Cable (33KV or 11KV Cable) (as per UPPWD approved make list) 163 Safely Dismantling of existing street lights including PVC Cable, bend pipe, clamp etc. from ST pole including cost of men and T&P with cartage site to JE store as per direction of E/I.(as per UPPWD approved make list) 164 Supply,Installation,Testing and Commissioning of Wall or Floor Mounted type 3.3 kW/230V,50Hz Electric Vehicle Chraging Station having 3-Pin socket(single)/Outpot- 3.3 Kw/16 Amps, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App,, SIM/Wi0Fi/GSM/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 165 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 7.2 kW to 7.5 kW Charger AC Single phase Type-2 AC charger, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 166 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 22 kW Charger 415V, 50 Hz, Type-2 AC, 32A outpot, with attached single Gun & cable Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 167 Supply, Installation , Testing and Commissioning of 7.0 MeterAutomatic boom barrier with RFID system comprising Hydraulic pumpunit , Plunger pistons, balancing by compression spring ,internal stopsadjustable for open or close beam positions ,System operating Voltage 230 ± 10 % Volt, AC 50 Hz, Reverse/Forward Motor, working power supply 24 V.D.C,including UHF RFID reader with pole5.0 KV online UPS ofMin. 30 minute back up for the Barrier . The Boom raise/lower time <= 0.8 sec ,Stand alone with push Button switch & wirelessremote control and cable with on/off switch and Remote can be integrated with Access,Control system with card, Key and Biomentic as per tender specification ,Optical beam sensor / photo cell be provided to prevent barrier from closing on the vehicles.Twin Channel Exit Push putton for open close with green and red Buttons.The control unit is housed in weather proofhousing with IP 54/ IP 55 Enclosure including cost ofconstructioncement/ concrete foundation, Y shape Barrier arm rest fixure, RFID tokens, Supply & fixing of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs,tags, identifiers, fixures, clamps, screws, nut - bolts etc. Men and T&Pas required for completion the work. (as per UPPWD approved make list) 168 Supply, Installation, Testing and Commissioning ofmulticolur traffic LED light of polycarbonate, 24 V DC Micro Controller based Traffic Signal Controller mounted in IP-65 M.S Powder coated Panel , 24V DC RED FULL LED Traffic Light with 300mm Polycarbonate housing.4V DC AMBER FULL LED Traffic Light with 300mm Polycarbonate housing, 24V DC GREEN Arrow LED Traffic Light with 300mm Polycarbonate housing, M.S powder coated Junction Box with terminal connectors,M.S clamps for fitting lights and suitable poleof approved material having upto 3 mm thikness with 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling complete in all respect including cost of all material,men and T&P.(as per UPPWD approved make list) 169 Supply, Installation, Testing and Commissioning of AIR QUALITY MONITORING SYSTEM/(OCEMS) With LED Display board of Size 6.0x4.0 ft or higher having Data logger(RS485 based), PM 2.5 Sensor, Pm 10 sensor, SO2 Sensor, CO2 Sansor, NO2 Sansor, CO Sensor, Noise& Smoke Sensor. The system shoubd be provision of Real time data display & downloding option,Wi-Fi/internet Computor connectivity, Cost of online UPS, Frame Fabrication & RCC foundation cost , Pole mounting acessories, installation charge online complete in all respect.(as per UPPWD approved make list) 170 Supply , installation of 5 zone central control unit (main frame) configured for 512 station, connection with EPABX & fire alarm system, 5 zone master control station,outdoor type ip 52 protection wall/column mounted station, weatherproof canopy,ip 65, 15w, horn type loud speaker, driver unit, station jb, loud speaker jb, desk top station, extension amplifier, cone type box,pdb with required incoming and out going feeder complete in all respect as per direction of E/I.(as per UPPWD approved make list) 171 Supply & Laying of 6 Core Signal & Loudspeaker Cable (Can be provided in 2 sets) and 3 core power cable in 50mm Dia HDPE Pipe. (as per UPPWD approved make list)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-10-2024 Extension of Date Date 14-10-2024

Key Value

Document Fees
INR 8850 /-
EMD
INR 2150000.0 /-
Tender Value
INR 9.08 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail