Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #45209934

Tender For Providing Of 07 Deficient Company Stores At Mrc Sagar Under Ge Saugor

Issued by Statutory Bodies & Commissions/Committees · saugor, Madhya Pradesh
Tender Value
39.97 Lakhs
Estimated cost
Bid Submission
28 Oct 2024
0 days left
EMD
79940
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
saugor → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For providing Of 07 Deficient Company Stores At Mrc Sagar Under Ge Saugor-- 1 GENERAL SUMMARY 2 Lump sum price worked out by the contractor against Schedule ‘A’Part- I (BUILDING WORKS)for the following building works:- 3 (a) Lump sump amount worked out by the contractor for Design, development of structural drawings as per the architectural drawing Nos CWE/ARCH-1/22/2024 Sheet No. 1/1, CWE/ARCH-2/22/2024 Sheet No. 1/2 to 2/2 and Construction of 07 deficient company stores as per architectural drawings, structural drawing, TD drawings, schedule of finishes & given specifications, etc complete all as specified and as directed. NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs/Government Engineering College before execution of work by the contractor. 4 Lump sum price worked out by the contractor for EXCAVATION ANDEARTH WORKas listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately) 5 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-III (Ref prepriced schedule attached seperately) 6 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-IV (Ref prepriced schedule attached seperately) 7 Lump sum price worked out by the contractor for PATH WORKS as listed in Schedule ‘A’Part- V (Ref prepriced schedule attached seperately) 8 SCH A Pt - IX (MISCELLANEOUS PARTS) 9 M&L moorum/red bajrifilling in trenches or paving laid in layers not exceeding 25 cm thick spread, levelled and rammed including watering etc complete all as specified and directed. 10 Material and labour for machine pressed precast concrete interlocking paver block glossy finished, chemically treated any shape and size confirming to IS-15658-2006 size of 60 mm thickness, M-35 Grade with grey cement and pigment overlaid on sand cusion of 25 mm thickcomplete all as specied and directed. 11 M & L for concealed point wiring for one light/bell or one ceiling fan/exhaust fan controlled by one one way switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 12 M & L for concealed point wiring for one 3 pin/5 pin 5 Amps socket outlet on same board with other switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 13 M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 14 M & L for concealed point wiring for one switch 5/6 pin 5/15 Amps socket on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.50 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 15 S&F modular 5-step speed fan Regulator of electronic type suitable for BLDC ceiling fan of 1200mm/1400mm sweep Hum free & speed variation not less than 120 watt, socket type in size complete all as specified and directed 16 S&F testing and commissioning of MCB SP 6-32 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. 17 S&F double door metallic sheet metal enclosure for MCB DBdouble door4 way 230 Volts with 200 Amps rated bus bars.Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate complete all as specified and directed. 18 S&F in replacement of SPN 32 Amps415 Vincluding making electrical coming/outgoing connections with lugs/thimbles,including taking down complete all as specified and directed. 19 M&L LED TL fitting 20 watt for surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver long life corresion resistance impact proof surface mounting IP66 Lumanires PChousing in opeal finish coverwith high brighness complete all as specified and directed. 20 S&F LED Bulk head designed for modern homes availave in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed. 21 M&L for Earthing complete building with galvanized mild steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge ofplate not less than 1.5m below normal ground level, connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers etc of galvanised iron or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common all as shown in elect plate No.3 of SSR Part-3 (2009) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium gradeconnected to earthing test point including GI light grade 20mm bore proction pipe and including necessary excavation & earth work in any type of strata complete all as specified and directed and testing on completion. Note : (i) Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode shall be included in quoted unit rate. (ii) Earth work in any type of soil i.e. excavation, returing filling and removal is also included in quoted unit rate. (iii)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself 22 Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approvedmainfactory fabricatedLT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCB, TPN, 415V, 50HZ, 63 Amps 10 KA - 01 No. (B) OUTGOING (i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED TypePhase indicator lamps for three phases set of three - 01 set (iii) Busbar chamber having insulated aluminium busbar, each suitable for 200 Amps for three phases and neutral -01 Set (iv) MCB, SPN, 230V, 50HZ, 20 Amps with rupturing capacity 10 KA - 05 Nos(v) Blank space for MCBs SPN - 02 Nos 23 M&L for40 mm dia GI pipe light grade laid under road and path for passing cable complete all as specified and directed. 24 M&L for Earthing complete building with galvanized mild steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge ofplate not less than 1.5m below normal ground level, connected to and including GI strip 25 X 4 mm by means of bolts, nuts, check nuts and washers etc of galvanised iron or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common all as shown in elect plate No.3 of SSR Part-3 (2009) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium gradeconnected to earthing test point including GI light grade 20mm bore proction pipe and including necessary excavation & earth work in any type of strata complete all as specified and directed and testing on completion. Note : (i) Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode shall be included in quoted unit rate. (ii) Earth work in any type of soil i.e. excavation, returing filling and removal is also included in quoted unit rate. (iii)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 27-Sep-2024 Date Amendment Date 10-Oct-2024
2 04-Oct-2024 Date Amendment2 Date 19-Oct-2024
3 10-Oct-2024 Amendmentall Other 21-Oct-2024
4 10-Oct-2024 Date Amendment3 Date 21-Oct-2024
5 10-Oct-2024 RevisedBOQ BOQ 21-Oct-2024
6 21-Oct-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-Oct-2024

BOQ

Name of Work:PROVN OF 07 DEFICIENT COMPANY STORES AT MRC SAGAR UNDER GE SAUGOR
Sl. No. Item Description
1GENERAL SUMMARY
2Lump sum price worked out by the contractor against Schedule ‘A’Part- I (BUILDING WORKS)for the following building works:-
3(a) Lump sump amount worked out by the contractor for Design, development of structural drawings as per the architectural drawing Nos CWE/ARCH-1/22/2024 Sheet No. 1/1, CWE/ARCH-2/22/2024 Sheet No. 1/2 to 2/2 and Construction of 07 deficient company stores as per architectural drawings, structural drawing, TD drawings, schedule of finishes & given specifications, etc complete all as specified and as directed. NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs/Government Engineering College before execution of work by the contractor.
4Lump sum price worked out by the contractor for EXCAVATION ANDEARTH WORKas listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately)
5Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-III (Ref prepriced schedule attached seperately)
6Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-IV (Ref prepriced schedule attached seperately)
7Lump sum price worked out by the contractor for PATH WORKS as listed in Schedule ‘A’Part- V (Ref prepriced schedule attached seperately)
8SCH \"A\" Pt - IX (MISCELLANEOUS PARTS)
9M&L moorum/red bajrifilling in trenches or paving laid in layers not exceeding 25 cm thick spread, levelled and rammed including watering etc complete all as specified and directed.
10Material and labour for machine pressed precast concrete interlocking paver block glossy finished, chemically treated any shape and size confirming to IS-15658-2006 size of 60 mm thickness, M-35 Grade with grey cement and pigment overlaid on sand cusion of 25 mm thickcomplete all as specied and directed.
11M & L for concealed point wiring for one light/bell or one ceiling fan/exhaust fan controlled by one one way switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
12M & L for concealed point wiring for one 3 pin/5 pin 5 Amps socket outlet on same board with other switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
13M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
14M & L for concealed point wiring for one switch 5/6 pin 5/15 Amps socket on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.50 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
15S&F modular 5-step speed fan Regulator of electronic type suitable for BLDC ceiling fan of 1200mm/1400mm sweep Hum free & speed variation not less than 120 watt, socket type in size complete all as specified and directed
16S&F testing and commissioning of MCB SP 6-32 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
17S&F double door metallic sheet metal enclosure for MCB DBdouble door4 way 230 Volts with 200 Amps rated bus bars.Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate complete all as specified and directed.
18S&F in replacement of SPN 32 Amps415 Vincluding making electrical coming/outgoing connections with lugs/thimbles,including taking down complete all as specified and directed.
19M&L LED TL fitting 20 watt for surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver long life corresion resistance impact proof surface mounting IP66 Lumanires PChousing in opeal finish coverwith high brighness complete all as specified and directed.
20S&F LED Bulk head designed for modern homes availave in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed.
21M&L for Earthing complete building with galvanized mild steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge ofplate not less than 1.5m below normal ground level, connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers etc of galvanised iron or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common all as shown in elect plate No.3 of SSR Part-3 (2009) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium gradeconnected to earthing test point including GI light grade 20mm bore proction pipe and including necessary excavation & earth work in any type of strata complete all as specified and directed and testing on completion. Note : (i) Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode shall be included in quoted unit rate. (ii) Earth work in any type of soil i.e. excavation, returing filling and removal is also included in quoted unit rate. (iii)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself
22Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approvedmainfactory fabricatedLT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCB, TPN, 415V, 50HZ, 63 Amps 10 KA - 01 No. (B) OUTGOING (i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED TypePhase indicator lamps for three phases set of three - 01 set (iii) Busbar chamber having insulated aluminium busbar, each suitable for 200 Amps for three phases and neutral -01 Set (iv) MCB, SPN, 230V, 50HZ, 20 Amps with rupturing capacity 10 KA - 05 Nos(v) Blank space for MCBs SPN - 02 Nos
23M&L for40 mm dia GI pipe light grade laid under road and path for passing cable complete all as specified and directed.
24M&L for Earthing complete building with galvanized mild steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge ofplate not less than 1.5m below normal ground level, connected to and including GI strip 25 X 4 mm by means of bolts, nuts, check nuts and washers etc of galvanised iron or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common all as shown in elect plate No.3 of SSR Part-3 (2009) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium gradeconnected to earthing test point including GI light grade 20mm bore proction pipe and including necessary excavation & earth work in any type of strata complete all as specified and directed and testing on completion. Note : (i) Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode shall be included in quoted unit rate. (ii) Earth work in any type of soil i.e. excavation, returing filling and removal is also included in quoted unit rate. (iii)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself

AI Tender Summary

OUR REF NO 45209934
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 39.97 Lakhs
LAST DATE 28-10-2024
Authority
Authority Name Military Engineer Services
Work Description Tender For providing Of 07 Deficient Company Stores At Mrc Sagar Under Ge Saugor-- 1 GENERAL SUMMARY 2 Lump sum price worked out by the contractor against Schedule ‘A’Part- I (BUILDING WORKS)for the following building works:- 3 (a) Lump sump amount worked out by the contractor for Design, development of structural drawings as per the architectural drawing Nos CWE/ARCH-1/22/2024 Sheet No. 1/1, CWE/ARCH-2/22/2024 Sheet No. 1/2 to 2/2 and Construction of 07 deficient company stores as per architectural drawings, structural drawing, TD drawings, schedule of finishes & given specifications, etc complete all as specified and as directed. NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs/Government Engineering College before execution of work by the contractor. 4 Lump sum price worked out by the contractor for EXCAVATION ANDEARTH WORKas listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately) 5 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-III (Ref prepriced schedule attached seperately) 6 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-IV (Ref prepriced schedule attached seperately) 7 Lump sum price worked out by the contractor for PATH WORKS as listed in Schedule ‘A’Part- V (Ref prepriced schedule attached seperately) 8 SCH A Pt - IX (MISCELLANEOUS PARTS) 9 M&L moorum/red bajrifilling in trenches or paving laid in layers not exceeding 25 cm thick spread, levelled and rammed including watering etc complete all as specified and directed. 10 Material and labour for machine pressed precast concrete interlocking paver block glossy finished, chemically treated any shape and size confirming to IS-15658-2006 size of 60 mm thickness, M-35 Grade with grey cement and pigment overlaid on sand cusion of 25 mm thickcomplete all as specied and directed. 11 M & L for concealed point wiring for one light/bell or one ceiling fan/exhaust fan controlled by one one way switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 12 M & L for concealed point wiring for one 3 pin/5 pin 5 Amps socket outlet on same board with other switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 13 M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 14 M & L for concealed point wiring for one switch 5/6 pin 5/15 Amps socket on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.50 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 15 S&F modular 5-step speed fan Regulator of electronic type suitable for BLDC ceiling fan of 1200mm/1400mm sweep Hum free & speed variation not less than 120 watt, socket type in size complete all as specified and directed 16 S&F testing and commissioning of MCB SP 6-32 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. 17 S&F double door metallic sheet metal enclosure for MCB DBdouble door4 way 230 Volts with 200 Amps rated bus bars.Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate complete all as specified and directed. 18 S&F in replacement of SPN 32 Amps415 Vincluding making electrical coming/outgoing connections with lugs/thimbles,including taking down complete all as specified and directed. 19 M&L LED TL fitting 20 watt for surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver long life corresion resistance impact proof surface mounting IP66 Lumanires PChousing in opeal finish coverwith high brighness complete all as specified and directed. 20 S&F LED Bulk head designed for modern homes availave in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed. 21 M&L for Earthing complete building with galvanized mild steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge ofplate not less than 1.5m below normal ground level, connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers etc of galvanised iron or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common all as shown in elect plate No.3 of SSR Part-3 (2009) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium gradeconnected to earthing test point including GI light grade 20mm bore proction pipe and including necessary excavation & earth work in any type of strata complete all as specified and directed and testing on completion. Note : (i) Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode shall be included in quoted unit rate. (ii) Earth work in any type of soil i.e. excavation, returing filling and removal is also included in quoted unit rate. (iii)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself 22 Supply, installation, connecting, commissioning and repalcement of LT panel with CPRI approvedmainfactory fabricatedLT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCB, TPN, 415V, 50HZ, 63 Amps 10 KA - 01 No. (B) OUTGOING (i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED TypePhase indicator lamps for three phases set of three - 01 set (iii) Busbar chamber having insulated aluminium busbar, each suitable for 200 Amps for three phases and neutral -01 Set (iv) MCB, SPN, 230V, 50HZ, 20 Amps with rupturing capacity 10 KA - 05 Nos(v) Blank space for MCBs SPN - 02 Nos 23 M&L for40 mm dia GI pipe light grade laid under road and path for passing cable complete all as specified and directed. 24 M&L for Earthing complete building with galvanized mild steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge ofplate not less than 1.5m below normal ground level, connected to and including GI strip 25 X 4 mm by means of bolts, nuts, check nuts and washers etc of galvanised iron or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common all as shown in elect plate No.3 of SSR Part-3 (2009) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium gradeconnected to earthing test point including GI light grade 20mm bore proction pipe and including necessary excavation & earth work in any type of strata complete all as specified and directed and testing on completion. Note : (i) Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode shall be included in quoted unit rate. (ii) Earth work in any type of soil i.e. excavation, returing filling and removal is also included in quoted unit rate. (iii)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself
Basic Detail
Tender No 83940/E8
Bidding Type Tender
Location
City saugor
State Madhya Pradesh
Key Dates
Publish Date 21 Oct 2024
Submission Date 28 Oct 2024
Open Date 30 Oct 2024
Finance
Tender Value 39.97 Lakhs
Tender Fee 500
EMD 79940
Exemption Available
Document List
f1b65021-ee82-4e84-9ee5-913481fa5b21.html
83940PrepricedSch.pdf
83940TenderDocuments.pdf
Alldrawings.pdf
BOQ_753845.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 10, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 19, 2024
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 21, 2024
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 21, 2024
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 21, 2024
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 28, 2024
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 28, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 30, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

f1b65021-ee82-4e84-9ee5-913481fa5b21.html

pdf

83940PrepricedSch.pdf

pdf

83940TenderDocuments.pdf

pdf

Alldrawings.pdf

xls

BOQ_753845.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender