| 1 | DESCRIPTION OF ITEMS |
| 2 | Excavationin trenches ,n exc 1.5m wide and n exc 1.5mtr in depth for foundation etc or for shafts ,well cesspts ,manholes etc n exc 10sqm on plan and n exc 1.5mtr in depth and getting out in soft / disintegrated rock complete all as specified and directed. |
| 3 | Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in harde/dense soil complete all as specified and as directed. |
| 4 | Returning, filling in,earth including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and as directed. |
| 5 | Filling under floor (except material) including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified. |
| 6 | Removing excavated materialn. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point. |
| 7 | M & L for Plain Cement Concrete type D2, 1 : 4 : 8 (40 mm graded aggregate) as in foundation filling and mass concrete for embedding of posts etc complete all as specified and directed. |
| 8 | M&L RCC M-25 (Design Mix) as in foundation, including raft, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and as directed. |
| 9 | M&L RCC M-25 (Design Mix) as in columns, pillars, piers etc complete all as specified and as directed. |
| 10 | M&L RCC M-25 (Design Mix) as in beams, cantilever, lintels etc complete all as specified and as directed. |
| 11 | M&L RCC M-25 (Design Mix) as in slabs supported on walls, beams and columns etc complete all as specified and as directed. |
| 12 | M&L RCC M-25 (Design Mix) as in chajjas complete all as specified and as directed. |
| 13 | M&L form work to sides and soffits of roof beams, lintels lever shelves incl supports over hang etc ruogh finished surfaces of concrete flat all as specified. |
| 14 | M&L form work to chullah hoods, chajjas and similar items incl edges rough finished surfaces of concrete flat all as specified. |
| 15 | M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide |
| 16 | M&L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, plinth beams or similar works vertical or to batter for rough finished surface of concrete |
| 17 | M&L form work to sides of pillars, posts, struts, columns for rough finished surface of concrete |
| 18 | M&L form work to soffits of suspended slabs such as roof slab landings and similar works n exc 200mm thick (horizontal or slopping) for rough finished surfaces of concrete flat all as specified. |
| 19 | M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and binding with ms wire (annealed) not less than 0.9mm dia quality all as specified. |
| 20 | Description same as above but, 5 mm dia and over and incl 10mm dia in stirrups, spacers and binders |
| 21 | Supply only water proofing compound, complete all as specified and directed. |
| 22 | M&L for Hardcore of Broken stone or boulders of gauge n exc 63mm, deposited spread and levelled in layers n exc 15 cm thick ,watered and rammed to a true surface |
| 23 | M&L for 100mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in subbase of floors etc, complete all as specified and directed. |
| 24 | Providing cement concrete 25 mm thick typeB-0 (1:2:4) using 12.5 mm graded agg as in sub base to flooring . |
| 25 | M & L,non skid joint free coloured ceramictiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 Sqm, in floors over and including 15 mm thick screed bed in CM 1:6 as in floor etc set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. |
| 26 | M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces on wall in CM 1:6 finished the plaster surfaces fair and even complete all as specified and directed. |
| 27 | . -ditto- as ier item no 26but in cm 1:4 (external surfaces) |
| 28 | M & Lprecast cement concrete Block Masonary with solid blocks type C1 1:3:620mm graded stone aggregateand setting in mortar 1:6etc complete all as spd and directed |
| 29 | M&L for applyingtwo coat OBD on newly plastered wall with airless electric sprayers over a coat of primer applied using airless electric sprayers over one coats of wall care putty of 1-1.5mm thickness prepared and sanded with electrically operated sanding machine. application tobe done through the authorised applicator of manufacturer complete all as specified and directed. |
| 30 | M&L for applyingtwo coat exterior emulsion paint (weather coatof Berger or equivelent ) on newly plastered wall with airless electric sprayers over a coat of primer applied using airless electric sprayers over one coats of wall care putty of 1-1.5mm thickness prepared and sanded with electrically operated sanding machine. application to be done through the authorised applicator of manufacturer complete all as specified and directed.. |
| 31 | S&F powder coated aluminium window , ventilator, shutters and kitchen cupboards, slidding typewithout sash bars, alumimium section weighing 0.55 kg/m including necessary joining cleats glazing clips, ruber packing, powder coated aluminium snap beading screws anodised aluminium fittings such assuitable handle (1 No) complete all as specified for add powder coating (minimum thickness of powder coating 50 micron) |
| 32 | S&F powder coated aluminium frame for windows, ventilators and kitchen cupboards frame with one or more rebates including joining cleat for fixing etc. complete all as specified add for powder coating (minimum thickness of powder coating 50 micron) |
| 33 | Supply and Fixing sheet glass 5.5mm thick ordinary quality and glazing with oil putty or rubber and aluminium beading in squares n. exc 0.5 sqm in each pane complete all as specified and directed. |
| 34 | M&L, preparing of new steel surfaceexceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 35 | M&L for PCC 1:3:6 type C-1 using 20mm graded stone for embedding of hold fast etc complete all as specified and directed. |
| 36 | S&F aluminium door & frame powder coating (minimum thickness of powder coating 50 micron) 2 mm thick incl 5.50mm thick tinted glass, fixed with anodized aluminium snap beading, glazing clips, joining clips, screws and 02 Nos of aluminium handle on each door shutter, aluminium anodized tower bolt 200mm long 02 Nos on each shutter and mortice lock device complete with double keys for each lock, 01 No floor spring for each shutter complete all as specified and directed with following specifications :-(a) Aluminium door frame =101.50x44.45mm(b) Aluminium style/top & middle rails of shutter=83.5x44.45mm(c ) Aluminium bottom rail of shutter=114.50x44.45mm(d) Aluminium door frame with shutters shall be fixed in position in brick wall opening as required according to site conditions including all fastening arrangements etc complete all as specified and directed. |
| 37 | S&F Door closer hydraulically regulateddesignation No. 3,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed |
| 38 | S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel |
| 39 | Supply & Fix GI powder coated snap grid frame work for false celling comprising of the following sections for making partitions of 600x600 mm size fixedto walls with rawl plugs & screws and hanged to roof with and including 4mm dia GI wire suspender of suitable length complete all as specified and as directed :- (i) main tee of size -32mmx24mmx0.3mm (ii) cross tee of size -26mmx24mmx0.3mm(iii) wall angle - 24mmx24mmx0.3mm |
| 40 | S & F 4 mm thick E-Board classic for, 595 x 595 mm size fixed with staples on snap grid as in ceilingcomplete all as specified and as directed. |
| 41 | M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete for Fe 410 (grade E-250 quality -A) |
| 42 | S&F M.S Framed work such as grills gratings etc with ends of bars sholdered and/or riveted into spikes ,framed guard bars /railings all as directed . |
| 43 | S&F Hard drawn steel wire fabric cut to length, bent to shape required and tying with and including mild steel wire (annealed) not less than o.9mm dia weight not exceeding4.00 kg per sqm including welding to existing frame work complete all as specified and as directed. |
| 44 | S&F galvanised mild steel wire cloth 0.56 mm nomonal dia of bar and 1.18 mm avrage width of aperture ,fixed with tined tacks or galvanised wire staples complete all as specified and as directed. |
| 45 | M&L Glazed coloured ceramic tiles 450 x 350 x 7 mm to 8 mm thick on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured cement to match colored tiles over 10mm thick in CM (1:4) on brick or concrete surfaces offinished rough to receive the glazed tiles .of any description or thickness in walls all as specified and directed by engg-in-charge |
| 46 | M&L for Providing cement concrete 40 mm thick typeB-0 (1:2:4) using 12.5 mm graded aggregate as infloor all as specified and directed by engg-in-charge. |
| 47 | M&L for vitrified Ceramic tiles light shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement incl screeding 15mm thick in CM 1:6 complete all as specified and directed. |
| 48 | M&L for machine cut kota stone slab flooring 18-20 mm thick with white marble all arond 150mm wideover and including 15mm thick cement screed bed in CM 1:6 laidand jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finshedpolishing in complete all as specified. |
| 49 | M&L for machine cut kota stone slab, 18-20 mm thick in riser and tread single piece on steps, skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:4 including grinding and mirror finshed polishing complete all as specified and directed. |
| 50 | M & L for non skid tiles, exterior grade, pattern of size 300x300mm, 8-10mm thick set and jointed in neat cement slurry and pointed in white/ coloured cement to match the shade as in floor over and including 15mm thick cement screed bed in CM 1:6 complete all as specified and as directed. |
| 51 | Excavating in post holes (or similar holes) each n exc 0.5cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, ®complete all as specified and as directed |
| 52 | S&F MS angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 ® complete all as specified and as directed. |
| 53 | S & F for Chain link mild steel galvanised fencing of 3 mm dia of wire and aperture 75 x 75 mm including line wire straining boldts etc rails & binding wire complete. |
| 54 | M&L for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc complete all as specified and as directed (each line wire to be measured) |
| 55 | M&L for two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on newly untreated steel surfaces of any description, not over10cm in width or girth,not otherwise described including preparation of surfaces complete all as specified and directed. |
| 56 | S & F MS round bars 5 mm dia as in reinforcement and over upto 10 mm dia cut to length bend to shape as required including cranking as in stirrups and nibs (6 mm dia). |
| 57 | Supply only 10mm dia & over mild steel round/TMT bar conforming to Fe-410 or Fe-310-0 as in tie bars for chain link fencing including necessary fabrication, cutting to length bending to shape as required, etc complete all as specified and directed. |
| 58 | Framed work such asin steel gate framed and side hung incl pintle hinges, stopes, hand made sliding bolt monkey tower bolt etc complete con- forming to Fe.290.Gde-E-165 |
| 59 | M&L 20mm thick granite (any type) work (table rubbed and polished) slab for wall tiling (veneering to wall) 12mm thick cement morter (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 60 | S&F for steel work as in tubular truss incl special shaped washer etc complete using erw or induction butt weld ed tubes ,including gusset plate pole etc . all as specified and directed. |
| 61 | S & F Fe 410-W (Gde -E-250) quality-A plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc. |
| 62 | Supply & fix purpose made crew bolts with hexogonal or square heads at one end and screwed the other , or screwed both ends , each screwed end to be fitted withwashers and one hexogonal or square nut 16-20 mm dia and exc. 22cm and nexc. 30 cm long complete all as specified and as directed. |
| 63 | M & L, Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws in single length complete all as specified and directed. |
| 64 | M & L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. |
| 65 | M & L for 75 mm thick cement concrete type C- 2, 1:3:6 (40mm graded aggregate)as in Sub base. |
| 66 | M & L for chequered cement concrete coloured tiles 30 cm x 30 cm x 20 mm thick , with grey cement and pigments, set & jointed in neat cement slurry and pointed with cement & suitable coloured pigment to match the tiles in floors overand including20 mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 67 | M & Lcement concrete type C2 1:3:6(40mm graded stone aggregate) in surface channels and drain complete all as specified and directed . |
| 68 | M& L for providing precast cement concrete PCC 1:2:4 type B1 (20mm graded stone aggregates) as in landings, cover slabs (for man holes etc.)chullah hoods,chajjas, water troughs, mangers, shelves and similar articles with plain faces |
| 69 | Excavation over areas n. exc 1.5 m depth and getting out in soft and loose soil. |
| 70 | Add for each additional 1.5m or part thereof in depth beyond the first 1.5m |
| 71 | M&L for Sand filling under floors or in foundationincluding watering and consolidation |
| 72 | M&L for brick work with sub class `B\" bricks straight or curved on plan exc 6m mean radius built in CM (1:6)complete all as specified. |
| 73 | M & L brick work, sub class \"B\", bricks in one and half brick thick honey comb walling old size bricks built in CM 1:6 |
| 74 | M & L broken bricks loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage well |
| 75 | M&L formwork to edges of concrete etc |
| 76 | M&L for point wiring Concealed with 1.5 Sqmm, single core (FRLS), PVC insulated with multistranded unsheathed copper conductor cable including rigid non- metallic PVC surface / concealed conduit 20 mm or higher dia, light grade ISI marked complete with all PVC conduit accessories / fittings and sunk switch boxes with 3 mm thick plastic laminated hard glossy surface sheet (white) top cover, including continuous earth wire ofPVC insulated, unsheathed, green in colour 1.5 Sqmm multistrand copper conductor (FRLS) connected to all fittings, sunken boxes and common earth and connected to earth dolly , screwed with Brass screws, cup washers complete all as specified and directed for the following :-(a) One light point/Fan point controlled by one, one way switch of 5/6 Amps. |
| 77 | (c) One 3/5 pin socket outlet 5/6Amp on same board with other switch of 5/6 Amp. |
| 78 | (d) One 3/5 pin 5/6 amps socket out-let point on independent board controlled by one, one way switch of 5/6 amps on independent board. |
| 79 | (f)All as per item 1 herein above but with 2.5 Sq mm cable (FRLS) for one 15/16 Amp socket outlet controlled by one switch on independent board and 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable as continuous earth wire complete. |
| 80 | S & F ,Modular Switch flush type, whitefinish,5/6 amps, single pole, one way all as specified and directed. |
| 81 | S&F Modular Switch, whitefinish,15/16 amps, single pole, one way,complete all as specified and directed. |
| 82 | S&FModular Socket outlet 3 pin, 5/6 amps and 2 pin 5/6 amps with sutter,complete all as specified and directed. |
| 83 | S&F Modular Socket outlet two in one 3 pin 5/6 amps and 3 pin 15/16 amps (multipurpose), with shutters,complete all as specified and directed. |
| 84 | S&F ceiling rose, surface bakelite, AC, 220/240 volts, 3 terminals, complete all as specified and directed. |
| 85 | S&FLamp holder,insulated body with back plate suitable for batten /angular fittings, fixed on with & including round block 8 cm dia, 4 cm depth, closed recessed type & making connection etc complete all as specified & directed. |
| 86 | S & F white cover plate with frame modular type of 03 module complte all as specified and directed. |
| 87 | S & F white cover plate with frame modular type of 08 module complte all as specified and directed. |
| 88 | S & F metal flush box modular type of 03 module complte all as specified and directed. |
| 89 | S & Fmetal flush box modular typeof 08 module complte all as specified and directed. |
| 90 | S & Fmetal flush boxmodular type of 12 module complte all as specified and directed. |
| 91 | Supply and fixing LEDIntegrated Batten T5box type surface mouted, (1x20 Watt) prewired including electric electrical connection with PVC insulated twin twistedcopper wire of size 0.75 Sqmm from ceiling rose to tube light fitting and including taking down old fitting complete all as specified and directed. |
| 92 | S&F Sub main wiring with two single run of 6 Sqmm (Normal cross sectional area) of single core unsheathed PVC insulated cable, 1100 volts grade multi stranded copper conductordrawn through with & including conduit of 25 mm dia or higher dia with and including necessary conduit accessories, surface/concealed type including 6 Sqmm stranded copper conductor PVC insulated cable as earth wire connected to common earth dolly, complete all as specified and directed. |
| 93 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) |
| 94 | S&F MCB DB sheet metal enclosure for DB, SPN, 4 way having protectionwith 200 amps rated bus bar, 240 volts, double door type, suitable for housing MCB\"s and isolators,concealed in wallcomplete all as specified and directed. |
| 95 | Supply and Fix MCB single pole, 240 volts, 6-32 Amps of 10 KA complete all as specified and directed. |
| 96 | Supply and Fix MCB single pole & Neutral 240 volts, 40 amps,of 10 KA complete all as specified and directed. |