Tender For Baragaon Nagar Panchayat Reorganization Water Supply Scheme Under Amrit 2.0; CIVIL WORK Pump House 2 Supply of all materials labour for Construction of Pumphouse (3.60 x 3.00 x 3.00 M) CUM Chloronating Room (2.80 x 1.50 x 3.00 M) Including all material labour t&p etc Complete as per design & drawing. As per type design of Jal Nigam as per direction of engineer incharge. 3 Supply of all materials labour for Construction of Additional Dozer Room at every zone for DMA (2..50 x 3.00 x 4.00 M) Including all material labour t&p etc Complete as per design & drawing. as per direction of engineer incharge 4 Supply of all materials labour for Construction ofMCS Room (8.00 x 5.00 x 4.00 M) Including all material labour t&p etc Complete as per design & drawing. as per direction of engineer incharge 5 RISING MAIN FOR ZONE 1 AND 2& BYE-PASS ARRANGEMENT 6 Supply of the following sizes of D.I. pipes Class K-9 conforming to latest I.S. 8329/2000 complete in all respect F.O.R. destination including all taxes and insurance including speials. 7 150 mm DI K-9 8 Supply of the following sizes of C.I. Double flanged sluice valves as per I.S. 780/1960 for testing 10kg/Sqcm F.O.R Destination including all taxes and Insurance. 9 150 mm. dia. 10 Excavation in ordinary soil (lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 10 KM from the center of the foundation trenches.as per direction of engineer incharge 11 Excavation for pipe line in all type of rock by chieselling /blastingincluding supply ofblasting materials and stacking properly useful materials with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within10 KM.as per direction of engineer incharge 12 Carting from the store (up to 8 Km.) The following sizes of D.I. double pipe K-9 and specials to the site of work lowering them in to trenches and laying true to alignment and gradient including jointing, testing of pipeline and including supply of jointing material such as nut & bolts, rubber insertion, white lead etc. com- plate but excluding cost of trenching and cutting of pipes etc. For making of lengths but including making joints. 13 150 mm. dia. 14 Carting of D/F Sluice valves of following sizes to the site of workslowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc. complete excluding values and specials required but including the testing etc. complete. 15 150 mm. dia. 16 Supply of all materials, labour T&P etc. required and construct masonry type sluice valves chamber as per type design including supply and materials labour, T&P etc. complete. 17 Supply of all materials, labour, T & P etc. required and construct thrust blocks in RCC 1:2:4 at the bends and below the Valves. 18 Dismantling and reinstatement of following type of surface including sorting out and staking of serviceablematerials of disposal of unserviceable materials up to a distance of 50 m. as per direction of engineer incharge 19 BITUMINOUS ROAD 20 C.C. ROAD 21 Renovation of O.H.T. :- Dismantiling of OHT Flooring , Removing weak concrete hacked, roughended and clean thoroughly of OHT Coloumn for strenthening of OHT Coloumn M S or Iron Work in Plain work Supply of Aporxy resin for Old surface to joint new surface of cement concrete.Jacketing of Cement Concrete 1:1:5:3 Coment Course Sand, Stone Grit Thickness 60 mm Around old coloumn in OHT Including labour T&P etc complete.Construction of RCC foundation of Coloumn Pedestal with 1:1:5:3 cement concrete Dismantling of inner portion old plaster including disposal of malba (vertical wall, cone wall, bottom dome and top dome ).Repairing of Railing of Stair and Balcony with 20mm GI Pipe including changing of old pipe and reflexing new pipe, 12 mm thick Plaster 1:3 Cement and Course sand andwater Proofing Coumpond Chemical over the tank intenal wall and bottom dome to remove the leakage and seepage of tank(vertical wall, cone wall, bottom dome and top dome ). Changing of old & Damaged manhole cover including its fixing Scafoldingfor repairing & Painting of OHT, Dismantling/ Fixing of Inlet, Outlet, Over Flow washout pipe of OHT ,Changing of inlet outlet and washout unserviceable DI Pipe including dismantiling of old pipeand fixing of new pipe 40mm thick PCC (1:2:4) flooring with cement coarse sand and 20mm gauge stone ballast laid in pannels finished with 3mm thick floating coat of neat cement over base concrete 75mm thick consisting of cement, local sand 40mm brick ballast in 1:4:8 including Painting two coats of approved paint Apex Ultima or varnish including supply of all materials, labour and T&P etc required for Proper completion of the work in OHT. as per direction of engineer incharge 22 Design & Supply of all materials, T&P etc required for construction of specified capacity OHT with specified stagingas per following requirements:- 23 Capacity-As Specified in Item No 1.1 to 1.12Grading of OHT- M--35 The food grade epoxy coating of FOSROC / CIEBA GAIKI or reputated brand on the all inside surface area of water container after treatment of water tightness.Stair case- Seperate two column basedRCC staircase and 1 m wide balcony with box type RCC structure at the entrance of the staircase to protect the entry of unwanted persons & locking arrangement with MS door.Railings- 20 mm dia G.I. Pipe (medium quality steel tubes as per IS 1239) railing consisting of 3 rows of with posts height (50x50x6 mm MS angle) (1.0 m) of same pipe around stair case (both sides), balcony & at the top dome periphery, including epoxy 3mm thick coating above base coat, 65mm dia GI pipe (medium quality steel tubes as per IS 1239) ladder with FRP coating from opening of top dome to inside the tank and top of bottom dome. Supply and fixing of CI man hole cover with locking device at opening on the top dome to go inside the tank. Ventilator and Water level indicator - RCC ventilator with SS grill (10 sqm at the spacing of 30 mm) with steel mosquito mesh,electronic digitalwater level indicator with ultrasonic sensor including supply & fixing of solar energy arrangements. Lightening conductor- A good quality lightening conductor covered with PVC casing Vertical pipes- Inlet Pipe - 150 mm, outlet pipe - 250 mm, overflow - 150 mm & washout pipe - 100 mmC.I. D/F pipe as per design criteria upto 1 m beyond the apron, IVC/Kirloskar sluice valve on inlet, out let & at wash out pipe, duck foot bend, puddle collers and bell mouths. 10 mm thick & 150 mm wide S S plate clamp for fixing of verticle pipes with RCC columns (minimum 2 clamps between ends of each pipe). It also includes bye pass arrangement of OHT. The velocity in the pipes shall not exceed 1.5 m/sFlooring, Apron & Drain- 100 mm thick PCC of 1:2:4 & 100 mm thick CC of 1:1:2 with 6 mm thick glass strips not more than 1 sqm area upto 2 m from outer edge of the columns of OHT, drain of size 200 mm x 200 mm with 150 mm thick CC of 1:1:2 including necessary sluice valve chambers and pipe line required for proper drainage of rain water from the campus.Sluice valve chambers- 3 nos. of sluice valve chamber (minimum size 1.5 x 1.5 x 1.5 m or larger size as per requirements of site) of brick work with 200 mm thick RCC slab..Sluice valve chambers- 3 nos. of sluice valve chamber (minimum size 1.5 x 1.5 x 1.5 m or larger size as per requirements of site) of brick work with 200 mm thick RCC slab.Two coat apex painting over one coat primer of approved colour of asian / berger paints after fixing of RCC surface with grinder, repair of minor holes, unevenness etc. proper completion of work.Soil bearing capacity- Structure shall be design on the basis of maximum bearing capacity of 8 tonne/sqm or minimum as per actual on the basis of test report of soil bearing capacity. as per direction of engineer incharge 24 Sub Zone of Proposed OHT 18 m Staging ( Including 1m made of Gl or as per site condition ) 25 Proposed OHT Zone-II 400 kl Capacity and 18 m Staging 26 Cost of Testing for bearing capacity of soil for various sites of proposed OHT 27 DISTRIBUTION SYSTEM 28 Supply of following sizes D.I. K-7 pipes,as per I.S.- 8329/2000 or its Latest ammenmendsuitable for pipe with rubber gasket, coupling, coupler, including supply of specials DI DF/DI DS like Tees, Vertical / Horizontal Bend, Gap Pieces required for case of sectional testing etc and making S/S joints all materials T&P etc. all complete. as per I.S. F.O.R. destination including all local cartage etc complete.. ( Rising main Purpose ) 29 250 mm dia D.I.K-7 30 200 mm dia D.I K-7 31 Supply of the following HDPE Pipes as per B.I.S. code no. 4984/2016 or its latest amendment including cost of 1 HDPE coupler per pipe length and all bend , reducer, tee and all type of spacial which are required in Electro fusion joint fitting inclusive of all taxes and duties, 3rd party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges etc. F.O.R. destination etc. complete 32 180 mm dia HDPE PN10/PE100 33 160 mm dia HDPE PN10/PE100 34 140 mm dia HDPE PN10/PE100 35 110 mm dia HDPE PN10/PE100 36 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 37 250 mm dia 38 200 mm dia 39 150 mm dia 40 100 mm dia 41 Supply of the following sizes of C.I. Double flanged scour valves as per I.S. 780 class-1 working pressure 10 kg/Sqcm F.O.R Destination including all taxes and insurance. 42 80 mm dia 43 Supply of 50 mm dia screwed down type air valve with gun metal seat at site stone including all taxes. 44 Supply of underground sluice valves type fire hydrant consisting of 80 mm dia tail pieces, 80 mm dia duck foot band and 63 mm dia standard make iron coupling with cap and chain etc. complete to IS.369/1995 at site including all taxes. 45 Excavation for pipe line work in ordinary soil(lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 10 KM from the center of the foundation trenches. as per direction of engineer incharge 46 Excavation for pipe line in all type of rock by chieselling /blastingincluding supply ofblasting materials and stacking properly useful materials with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 10 KMas per direction of engineer incharge 47 Dismantling and reinstatement of following type of surface including sorting out and staking of serviceablematerials of disposal of unserviceable materials up to a distance of 50 m. as per direction of engineer incharge 48 INTERLOCKING ROAD 49 BITUMINOUS ROAD 50 C.C. ROAD 51 Carting from store (upto 8 Km) the following sizes of D.1. Pipes (class K-9) and AC pipes (class-15) and specials to the site of work, lowering them in to trenches and taying true to alignment and gradient including testing of pipeline D.I. (K-9) pipes 52 250 mm dia D.I.K-7 53 200 mm dia D.I K-7 54 Carting of following pipes, specials and fittings from site store to site of work, lowering them into trenches, laying true to alignment and gradient, laying and jointing with electro fusion fitting of pipe line including cutting of pipe for making up lengths as required for proper completion of work. 55 180 mm dia HDPE PN10/PE100 56 160 mm dia HDPE PN10/PE100 57 140 mm dia HDPE PN10/PE100 58 110 mm dia HDPE PN10/PE100 59 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge. Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 60 250 mm dia 61 200 mm dia 62 150 mm dia 63 100 mm dia 64 Carting of scour valves to the site of workslowering them into already Prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete. 65 80 mm dia 66 Carting of 50 mm dia screwed down air valves of following sizes to the site of workslowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete. 67 Carting of 80 mm dia flanges fire hydrant of the site of workslowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete. 68 Supply of all materials, labour T&P etc. required and construct masonry type sluice / scour valve chamber as per type design including supply and materials labour, T&P etc. complete. 69 Masonry type 70 Supply of all materials, labour T&P Etc. required and construct 350 x 350 x 500 mm size air valve chamber as per type design including supply and fixing the 500 mm dia CI manhole cover. 71 Supply of all materials, labour T&P Etc. required and construct 750 x 750 x 1000 mm size fire hydrant chamber as per type design including supply and fixing the 500 mm dia CI manhole cover. 72 Construction of thurst block in RCC 1:2:4 at bends & Tee in feeder main to DMAsincluding supply of all labour, material, T&P etc. complete as per the details given below :-No. of DMAs - 4Total no. of bends & Tee - 120 (considering 3 no. bends & Tee in each DMA)Qty. of concrete - 120 x 0.5 cum = 60 cum. (considering 0.5 cum concrete at each bend) 73 Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 74 Brick masonry in cement mortar 1:4 75 12mm thick plaster in cement mortar 1:4 76 Providing and laying in position reinforced cement concrete (mix 1:1.5:3)including batching, mixing, placing, vibrating, curing, formwork, finishing,including cost ofall material (Providing nominal reinforcement @ 0.15% of above itemincluding cutting bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete (including cost of binding wire and MS Bar)) and labour, tools and plants required with transportation, loading, unloading,etc., complete for all leads and lifts etc required for proper completion of the work. 77 Provision for crossing of Nalas (0.5mto 2.0 m width) for laying of pipe line including necessary specials, T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain. 78 0.3 - 0.5 m 79 0.5 - 1.0 m 80 1.0 - 1.5 m 81 1.5 - 2.0 m 82 Making House Connection in Distribution main including Dismantling of Road, Supply, carting of Specials lowering them into trenches, fixing them including bailing out of water necessary labour, T&P etc. required for proper completion of worksas per direction of engineer incharge 83 250 mm dia D.I.K-7 84 200 mm dia D.I K-7 85 180 mm dia HDPE PN10/PE100 86 160 mm dia HDPE PN10/PE100 87 140 mm dia HDPE PN10/PE100 88 110 mm dia HDPE PN10/PE100 89 Provision of Shifting water house hold connection. 90 For140 mmto 160 mm dia 91 For110 mm dia 92 Barricading of pipe line trenches by using 2 m high hard MS barricading board 2.5x2.0 M, with red flags, Glow-caution boards, diversion boards & red lights. 93 BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD 94 Construction of compound wall comprising of RCC Columns @ 3.0 m c/c distance with beam at plinth and top, brick work in 1:4 of as per type design including supply of all material, labour, T& P etc complete ( 2m height above plinth level 230 mm thick brick wall )as per direction of engineer incharge 95 Supply and fixing 3.60 m wide MS main gate & 1.0 m wide a wicket gate with RCC Columns as per type design & drawing including primer and painting, meterial, labour, T&P etc all complete, as per direction of engineer incharge 96 Supply and Carting of additional earth required to fill up the site to the required formation level At Zone -I and At Zone -II including leveling dressing ramming with proper compection work completed. as per direction of engineer incharge 97 Provide all materials, labour T&P etc. required for proper completion of work and construction of interlocking approach road in water works campous. At Zone -I and At Zone -IIas per direction of engineer incharge 98 Construction of 250X250 mm size drain at W/W sites At Zone -I and At Zone -IIas per direction of engineer incharge 99 GENERAL RESIDENTIAL QUARTERS 100 Construction of staff quarters (1 G.F) including other miscellaneous works. The plinth area of each staff quarter is 57.706 sqm. As per jal nigam type designas per direction of engineer incharge 101 construction ofStaff Quarter at Zone-I 102 construction ofStaff Quarter at Zone-II 103 E AND M WORKS 104 CONSTRUCTION OF NEW TUBEWELL (ZONE-1) 105 Resistivity and hydrological Survey 106 Transportation from store: 107 Transportation, Erection, Dismantiling of DC/RC/DTH Rig machine 108 Transportation, Erection, Dismantiling of 150 PSI Compressor 109 Transportation, Erection, Dismantiling of 1 Cusec / 3 Cusec OP Unit and Yield test 110 Drilling of Tube well bore : 111 Drilling and reaming of 600mm dia bore from GL to 60 m BGL by DC method 112 Bentonyte Powder Bags 113 Tube Well Assembly : 114 M.S. Tubewell Assembly with all required parts like planin pipe, slotted pipe, rings, well cap, bail plug, clamp, reducer, central guide, support structure etc. as required & per typed design complete in all respect. 115 300mm dia M.S.E.R.W. houseing plain pipe of wall thickness 7.1 mm. 116 Lowering of Tube well Assembly 117 Electrical logging of the bore 118 Lowering of 300mm. Dia M.S. housing pipe G.L. to 59 mtr. BGL 119 Supply of 1.6 to 4.8mm size pea gravel and shrouding of tube well 120 Development of Tube well 121 By Air Compressor 122 Development of Tube well by 150 PSI capacity air compressor 123 By Over Pumping Unit 124 Development of Tube well by OP Unit 125 Chemical & Bacteriological test of water 126 PUMPING MACHINARY TO FEED 400 KL OHT (ZONE-1) 127 SITC of Pumping Plant including, panel, cable, complete in all respect with all required material T&P labour etc. (1000LPM , 61 m Head , 2900RPM, 25 H.P) 128 SITC of Main piping & Valves with 24 mtr. Column pipe, Painting, Tools with wiring of pump house (internal & external) complete in all respect with required material, T&P labour, chain pully and gauges. - 150 mm dia 129 TOOLS (REPUTED MAKE ) IN A TOOL KIT - 1 Set1. Pipe wrenches - 2 No.2. D/E Spanner 22/6 mm - 6 Pcs3. Adjustable wrench 300 mm- 1No.4. Screw driver5. 250 mm- 1No.6. 200 mm - 1No.7. 150 mm- 1No.8. Combination pliers 200 mm- 1No.9. Nose pliers 150 mm - 1No.10.hammer with handle 1 kg.- 1No.11. Line tester (Taparia make)- 1No. 130 SITC of Soft Starter with RS 485 Port- 400 V Class, 18.5 KW, Rating 131 SITC of Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank. ( SCADA Compatible ) 132 SITC of Motor Operated Actuator with Sluice Valve - 150 mm size 133 SITC of CE/UL Certified Electromagnetic Flowmeter-150 mm size 134 SITC of Servo voltage stabilizer oil cooled having capacity 40 KVA fully copper winding three phase A.C supply 50 Hz. Input voltage 240-450 output voltage 415 volt +/- 1% withearthling wire and power cable 135 SITC of Auto Phase reversal unit with inbuilt time delay & enclousare ( confirm to IEC:60947-1 & IEC:-60947-b-1) 136 125 Amp Rating 137 ElectricalWorksfor Zone-1 138 Electrical System ( For Tubewell ) 139 Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - internal & external lighting of 01 tubewell as follows:- 140 Indoor Lighting 141 Surface Mounting 142 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 143 Suspended Mounting / Surface Mounting 144 36W LED light fixture 2×2 with acrylic / prismatic front cover. 145 Outdoor Lighting 146 Supply and fixing of all in one solar LED light fixture with integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. 147 Compact Solar LED Street Light- 60W(MONO)18V / 12.8V27Ah /40W for TW & MCS 148 Complete wiring of Pump house with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 149 Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories 150 Electrical System ( MCS ) 151 Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - internal & external lighting of MCS as follows:- 152 Indoor Lighting 153 Surface Mounting 154 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 155 Suspended Mounting / Surface Mounting 156 36W LED light fixture 2×2 with acrylic / prismatic front cover. 157 Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required.(For MCS) 158 450mm sweep (900/1400 RPM) 159 Outdoor Lighting 160 Supply and fixing of all in one solar LED light fixture with integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. 161 Compact Solar LED Street Light- 60W(MONO)18V / 12.8V27Ah /40W for TW & MCS 162 Complete wiring of MCS with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 163 Instrumentation Worksfor Zone-1 164 Automation of Proposed OHT ( 400 KL ) with DMA 165 Supply of Motor operated actuator without sluice valve at OHT outlet :- Supply of DI/DF Electrically integrated actuater without sluice valve (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 166 250 mm dia 167 Supply of flow control valve with electric actuator for flow controling,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. 168 200 mm 169 Supply of dismantling joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia at DMA inlet. 170 200 mm 171 Supply of CE/UL Certified level transmitter for OHT :- Supply of Radartype leveltransmitter with CEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 172 Supply of CE/UL Certified Electromagnetic flow meter at DMA inlet :- SupplyofCE/ULFullBore ElectromagneticFlowMeterofapproved make for remote placesof following dia and specificationscomplete:Media: Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable and also interfacing with PLC panel. 173 200 mm dia 174 Supply of CE/UL Certified Pressure transmitter at DMA inlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 175 Supply of Dosing System at DMA inlet :-Supply of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.( SCADA Compatible ) 176 Supply of Residual chlorine analyser / meter at DMA inlet :-Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V ac+B7Output : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must beprovided to avoid maintenance. IP 65 Nema 4 housing protection class required. 177 Installation, cabling of OHT including all equipments with all power and control cable,testingand commissioning complete in all respect. 178 Master Control Station (MCS) 179 CE & BIS approved manufacturers industrial grade LCD monitor with latest configuration as per specification of size 65 180 Desktop/PC as per spec. mentioned 181 CE/UL approved manufacturers 5 KVA UPS with batteries as spec. mentioned for Computer as per requirement 182 Full development version of required TAGS SCADA Software with customization of software for MCS as per requirement as per specification mentioned. 183 CE & UL approved manufacturers control room PLC with CPU & power supply at MCS in IP65 enclosure as per spec. mentioned 184 CE/UL certified field gateway agent for transfering data from MCS to control room 185 GSM based wireless / broadband/Equipment communication system for PLC capable to transfer and gather data from remote sites to control stations, including all accessories complete 186 CE/UL approved manufacturers Firewall for network protection 187 Lightning surge protector for ethernet communication protection 188 CE/UL approved manufacturers industrial grade ethernet switch 189 Mobile App facility system architecture complete. 190 Canon/HP 1018/equivalent Laser printer 191 Security Survelliance IP camera 192 Installation, testing and commissioning with required furniture,Air Conditioner etc 193 Automation of Tubewells (Zone-1) 194 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 195 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 196 CE & UL certified Inteligent Smart Energy Meter 197 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 198 CE & UL certified pressure transmitter 199 CE & UL certified Surge protector for above control panel 200 CE/UL approved manufacturers 3 KVA UPS with batteries as spec. mentioned for Computer as per requirement 201 CE & UL certified 7 HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 202 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT both. 203 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 204 Installation, commissioning & testing for tubewells 205 AUTOMATION OF DMA (ZONE-1) 206 CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit withCPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 207 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 208 CE/UL Certified Intelligent energy meters 209 CE/UL Certified Surge protector for control panel 210 CE/UL Certified 1 KVA UPS with batteries as per technical bid documents 211 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 212 Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments 213 Cable 214 (i) Complete cabling 215 Security Survelliance IP Camera with recorder (optional) 216 Installation, commissioning & testing 217 CONSTRUCTION OF NEW TUBEWELL ( ZONE-2) 218 Resistivity and hydrological Survey 219 Transportation from store: 220 Transportation, Erection, Dismantiling of DC/RC/DTH Rig machine 221 Transportation, Erection, Dismantiling of 150 PSI Compressor 222 Transportation, Erection, Dismantiling of 1 Cusec / 3 Cusec OP Unit and Yield test 223 Drilling of Tube well bore : 224 Drilling and reaming of 600mm dia bore from GL to 60 m BGL by DC method 225 Bentonyte Powder Bags 226 Tube Well Assembly : 227 M.S. Tubewell Assembly with all required parts like planin pipe, slotted pipe, rings, well cap, bail plug, clamp, reducer, central guide, support structure etc. as required & per typed design complete in all respect. 228 300mm dia M.S.E.R.W. houseing plain pipe of wall thickness 7.1 mm. 229 Lowering of Tube well Assembly 230 Electrical logging of the bore 231 Lowering of 300mm. Dia M.S. housing pipe G.L. to 59 mtr. BGL 232 Supply of 1.6 to 4.8mm size pea gravel and shrouding of tube well 233 Development of Tube well 234 By Air Compressor 235 Development of Tube well by 150 PSI capacity air compressor 236 By Over Pumping Unit 237 Development of Tube well by OP Unit 238 Chemical & Bacteriological test of water 239 PUMPING MACHINARY TO FEED 450 KL OHT (ZONE-2) 240 SITC of Pumping Plant including , panel, cable, complete in all respect with all required material T&P labour etc. (1000LPM , 61 m Head , 2900RPM, 25H.P) 241 SITC of Main piping & Valves with 24 mtr. Column pipe, Painting, Tools with wiring of pump house (internal & external) complete in all respect with required material, T&P labour, chain pully and gauges. - 150 mm dia 242 TOOLS (REPUTED MAKE ) IN A TOOL KIT1. Pipe wrenches - 2 No.2. D/E Spanner 22/6 mm - 6 Pcs3. Adjustable wrench 300 mm - 1 No.4. Screw driver5. 250 mm - 1 No.6. 200 mm- 1 No.7. 150 mm - 1 No.8. Combination pliers 200 mm - 1 No.9. Nose pliers 150 mm - 1 No.10. hammer with handle 1 kg. - 1 No. 243 SITC of Soft Starter with RS 485 Port- 400 V Class, 18.5 KW, Rating 244 SITC of Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank. ( SCADA Compatible ) 245 SITC of Motor Operated Actuator with Sluice Valve - 150 mm size 246 SITC of CE/UL Certified Electromagnetic Flowmeter-150 mm size 247 SITC of Servo voltage stabilizer oil cooled having capacity 40 KVA fully copper winding three phase A.C supply 50 Hz. Input voltage 240-450 output voltage 415 volt +/- 1% withearthling wire and power cable 248 SITC of Auto Phase reversal unit with inbuilt time delay & enclousare ( confirm to IEC:60947-1 & IEC:-60947-b-1) 249 125 Amp Rating 250 Electrical Worksfor Zone-2 251 Electrical System ( For Tubewell ) 252 Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - internal & external lighting of 01 tubewell as follows:- 253 Indoor Lighting 254 Surface Mounting 255 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 256 Suspended Mounting / Surface Mounting 257 36W LED light fixture 2×2 with acrylic / prismatic front cover. 258 Outdoor Lighting 259 Supply and fixing of all in one solar LED light fixture with integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. 260 Compact Solar LED Street Light- 60W(MONO)18V / 12.8V27Ah /40W for TW 261 Complete wiring of Pump house with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 262 Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories 263 Instrumentation Worksfor Zone-2 264 Automation of Proposed OHT ( 450 KL ) with DMA - Zone-2 265 Supply of Motor operated actuator without sluice valve at OHT outlet :- Supply of DI/DF Electrically integrated actuater without sluice valve (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 266 250 mm dia 267 Supply of flow control valve with electric actuator for flow controling,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. 268 200 mm 269 Supply of dismantling joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia at DMA inlet. 270 200 mm 271 Supply of CE/UL Certified level transmitter for OHT :- Supply of Radartype leveltransmitter with CEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 272 Supply of CE/UL Certified Electromagnetic flow meter at DMA inlet :- SupplyofCE/ULFullBore ElectromagneticFlowMeterofapproved make for remote placesof following dia and specificationscomplete:Media: Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable and also interfacing with PLC panel. 273 200 mm dia 274 Supply of CE/UL Certified Pressure transmitter at DMA inlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 275 Supply of Dosing System at DMA inlet :-Supply of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.( SCADA Compatible ) 276 Supply of Residual chlorine analyser / meter at DMA inlet :-Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V ac+B7Output : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must beprovided to avoid maintenance. IP 65 Nema 4 housing protection class required. 277 Installation, cabling of OHT including all equipments with all power and control cable,testingand commissioning complete in all respect. 278 Automation of Tubewells (Zone-1) 279 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 280 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 281 CE & UL certified Inteligent Smart Energy Meter 282 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 283 CE & UL certified pressure transmitter 284 CE & UL certified Surge protector for above control panel 285 CE/UL approved manufacturers 3 KVA UPS with batteries as spec. mentioned for Computer as per requirement 286 CE & UL certified 7 HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 287 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT both. 288 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 289 Installation, commissioning & testing for tubewells 290 AUTOMATION OF DMA (ZONE-2) 291 CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit withCPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 292 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 293 CE/UL Certified Intelligent energy meters 294 CE/UL Certified Surge protector for control panel 295 CE/UL Certified 1 KVA UPS with batteries as per technical bid documents 296 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 297 Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments 298 Cable 299 (i) Complete cabling 300 Security Survelliance IP Camera with recorder (optional) 301 Installation, commissioning & testing 302 TRAIL & RUN (Without Electricity) for03 Months Trial & Run for Zone-1,2