| 1 | Cement OPC 33 Grade/43 Grade/53 Grade complete as per IS 269/8112/12269 for Chemical Analysis only |
| 2 | Cement OPC 33 Grade/43 Grade/53 Grade complete as per IS 269/8112/12269 for Physical Testing only |
| 3 | Cement PPC-Complete as per IS:1489 for Chemical Analysis only |
| 4 | Cement PPC-Complete as per IS:1489 for Physical Testing only |
| 5 | Compressive Strength of Concrete cube 3 Cubes |
| 6 | Compressive Strength of Brick after filling 5 Nos. bricks |
| 7 | Building Bricks as per IS:1077 (20 Bricks) |
| 8 | Glazed Tiles as per IS:777 Except Warpage ( 80 Tiles) |
| 9 | Tarrazo Tiles as per IS:1237 (Mosaic Tiles) (20 Tiles) |
| 10 | Chequered Cement concrete Tiles IS:13801 (20 Tiles) |
| 11 | Coarse Aggregate as per IS:383 (25 kg.) |
| 12 | Fine Aggregate as per IS:383 (20 Kg.) |
| 13 | Marble as per IS:1130/Kota (1\" x 1\") |
| 14 | Gypsum Plaster Board IS:2095 (1mx 1m) |
| 15 | Structural Granite IS:3316 (4 Slab) |
| 16 | Acid Resistant Tiles IS:4457 (20 Nos.) |
| 17 | Gypsum Agricultural Grade IS:6046 (500 gm) |
| 18 | White cement IS:8042 (10 Kg) |
| 19 | Ratio of Ingredients of Concrete (cement to total Aggregate) (5 Kg) |
| 20 | Ratio of Ingredients of Cement Mortar (2 kg) |
| 21 | Each Subsequent - Mix Design (Coarse Agg, Sand and Cement) |
| 22 | Hammer test for concrete (for 25 point) As per IS:13311 |
| 23 | Tor Steel - Complete as per IS:1786 Chemical Analysis (1.0 Mtr.) |
| 24 | Tor Steel - Complete as per IS:1786Physical Testing only (1.5 Mtr.) |
| 25 | G.I. Pipe as per IS:1239 (upto 100mm) (1.5 Mtr.) |
| 26 | G.I. Pipe Fittings |
| 27 | Water for construction purpose of IS:456 (2.00 Ltr.) |
| 28 | PVC pipe (with pressure test) IS:4985 (1.00 mtr) |
| 29 | PVC pipe (with out pressure) IS:4985 (1.00 mtr) |
| 30 | PVC PipeFittings |
| 31 | UPVC Pipe (as per specification) |
| 32 | UPVC Pipe Fittings |
| 33 | Cable/Wire IS:694 (15.00 Mtr.) |
| 34 | SCI pipe as per IS:1729 (1 Full Length) |
| 35 | G.I. Steel Barbed Wire IS:278 (5.00 Mtr.) |
| 36 | C.I. Pipe IS:1536 (upto 100mm) Except tensile (1 Length) |
| 37 | Identification of Wood + Moisture content (6 inch. length) |
| 38 | Flush Door Shuttersper IS:2202 (Part I) (End immersion, Knife test & Glue adhesion only) (Full shutter) |
| 39 | Ply Board as per IS:303 (2X1.00 mtr) |
| 40 | Particle Board IS:3087Except Tensile str. perpendicular to surface, accelerated water resistance (2X1.00 mtr) |
| 41 | Veneered Particle Board IS:3097Except - Static Bending under sustained load (2X1.00 mtr) |
| 42 | M. D. F. Board for G. P. IS:12406 Except Tensile Strength Perpendicular to surface, Thermal conductivity, Internal Bond test (2X1.00 mtr) |
| 43 | Pre laminated Particle Board-IS 12823-90 Except Tensile Strength Perpendicular to surface before .& after ageing Resistance to abrasion— Abrasion Resistance in No. of revolutions (2X1.00 mtr) |
| 44 | Job mix formula for bitumen (Asphalt institute Manual MS-2) |
| 45 | Kerb stone IS:5758 (5 Nos) |
| 46 | GSB As per MORTH specification (30 Kg) |
| 47 | WMM As per MORTH specification (30 kg) |
| 48 | Soil investing test including CBR value, dry density/Moisture content (as per specification) |
| 49 | RCC pipe (as per specification) |
| 50 | Core cutting per core with testing (as per specification) |
| 51 | DGBM (as per Morth specification) |
| 52 | BC (as per Morth specification) |
| 53 | Bitumen concrete core(as per specification) |
| 54 | Bitumen (IS;15462, 73) |
| 55 | Admixture (as per specification) |
| 56 | M.S. Pipe (as per specification) |
| 57 | Bollard (as per specification) |
| 58 | Aluminum Section (as per specification) |
| 59 | Fixed frame Section (as per specification) |
| 60 | Open able pram shutter (as per specification) |
| 61 | CPVC pipe (as per specification) |
| 62 | CPVC Fitting (as per specification) |
| 63 | M.S. Angle & M.S. Flat (as per specification) |
| 64 | ACC Block (as per specification) |
| 65 | Fly ash bricks (as per specification) |
| 66 | Granite 18 mm thick (as per specification) |
| 67 | HDPE Pipe (as per specification) |
| 68 | Paver Block 80 mm/60 mm |
| 69 | M S Conduit Pipe |
| 70 | M S Plates (Different Thickness) IS 2062-2011 |
| 71 | DWC Pipe (IS 16098 Part-2) |