Tender For Construction Of Running Cold Water Distribution At Masjid At 256 Sl. No. Item Description 1 [Ref: P.W.D. (Building) Item No.2(A), Page-1] Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil (Including Mixed Soi, Jalpaiguri-West Bengal

Local Bodies has published Tender For Construction Of Running Cold Water Distribution At Masjid At 256 Sl. No. Item Description 1 [Ref: P.W.D. (Building) Item No.2(A), Page-1] Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil (Including Mixed Soi. Submission Date for this Tender is 19-08-2024. Shed Construction Tenders in Jalpaiguri West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

44634018
Corrigendum : Tender For Construction Of Running Cold Water Distribution At Masjid At 256 Sl. No. Item Description 1 [Ref: P.W.D. (Building) Item No.2(A), Page-1] Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil (Including Mixed Soi
Open Tender
Indian
West Bengal
Jalpaiguri
19-08-2024

Tender Details

tender for CONSTRUCTION OF RUNNING COLD WATER DISTRIBUTION AT MASJID AT 256 Sl. No. Item Description 1 [Ref: P.W.D. (Building) item no.2(a), Page-1] Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as requiredcomplete.(a) Depth of excavation not exceeding 1,500 mm. 2 [Ref: P.W.D. (Building) item no.4, Page-2] (A)Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by through saturation with water ,ramming complete including the cost of supply of sand .(payment to be made on measurement of finished quantity) 3 [Ref: P.W.D. (Building) item no.1, Page-14] Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand 4 [Ref: P.W.D. (Building) item no.1(a), Page-34] (1)Cement concrete with graded stone ballast (40mm size excluding shuttering )in ground floor(2)Cement concrete with 30mm down graded shingles excluding shuttering N.B.variety.In ground floor (a)1:3:6 propotion 5 [Ref: P.W.D. (Building) item no.10(ii), Page-26]Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (ii ) River Bazree 6 [Ref: P.W.D. (Building) item no.40(ii), Page-44] Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a)For works in foundation, basement and upto roof of ground floor/upto 4 m(i) Tor steel/Mild Steel.II. Other than SAIL/TATA/RINL 7 [Ref: P.W.D. (Building) item no.36(a), Page-42]Hire and labour charges for shuttering with centering and necessary staging upto 4m using approved stout props and thicks hard wood planks of approved thickness with required bracing for concrete slabs,beams and lintels curved or straight including fitting,fixing and striking out after completion of works(upto roof of ground floor)(a)25mm to30mm thick wooden shuttering as per decision of engineer-In-Charge. 8 125mm thick brick work with 1st class bricks in cement morter (1;4)in ground floor. 9 [Ref: P.W.D. (Building) item no.35(i), Page-64]Supplying,fitting and fixing 1st quality ceramic tiles in walls and floors to match with the existing work & 4nos. Of key stones (10mm)fixed with araldite at the back of each tile finishing the joints with white cement mixed with colouring oxide if requred to match the colour of tiles including roughening of concrete surface,if necessary or by synthetic adhesive & grout materials etc.(A)Floor with sand cement morter(1:4)20mm thick &2mm thickness slurry at back side of tiles using cement @2.91kg/sq.m & joint filling using cement slurry @0.20kg/sq.m.(a)Area of each tile upto 0.09 sq.m. 10 [Ref: P.W.D. (Building) item no.35(i), Page-64 (B)wall with Sand Cement Morter (1:3)15mm thick &2mm thick cement slurry at back side of tiles using cement white cement slurry @0.20kg/sq.m.(a)Area of each tile upto 0.09sq.m(1)coloured decorative. 11 [Ref: P.W.D. (Building) item no.13a(i), Page-102](A)M.S or W.I. Ornament grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows,railing etc.fitted and fixed with necessary screws and lugs in ground floor.(add extra @1%for each addl.floor upto 4th floor and @1.25%for each addl.floor above 4th floor)(1)grill weighting above 10kg/sq.mtr and upto16kg/sq.mtr.the weight of grill per sq.m will be determined by taking the physical weight of fabricated grill and diving the same by covered area of the same. 12 Item no-02, Page no -100 of PWD schedule M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1957 & IS: 1161- 1958 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables suchas electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof 13 Item no-02, Page no -100 of PWD schedule Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(GCI sheet to be supplied by contractor)a) With 0.60 mm thick shee 14 [Ref: P.W.D. (Building) item no.14(iii), Page-197]Applig decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly(plastered or concrete surface)as per manu 15 [Ref: P.W.D. (Building) item no.2(d), Page-190] Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary (ground floor) (ii) With 1:4 cement mortar(b) 15 mm thick plaster 16 [Ref: P.W.D. (Building) item no.2(i), Page-200] (b)On steel or other metal surface:With super gloss (hi-gloss)(4)Two coats (with any shade except white) 17 Supply fitting &fixing 1nos aquaguard stroage cooler cum purifier including fitting fixing complete L.S 18 Supply fitting fixing of 1hourse power water pump 19 Supply fitting & fixing of water tank of 500 ltr 20 Electrictification 21 Plumbing works including pipe,elbow ect. All complete L.S 22 Display board 23 GST 18% 24 LC 1%

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-08-2024 BANK SOLVENCY CERTIFICATE NOT REQUIRED Other 19-08-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 5514.0 /-
Tender Value
INR 2.75 Lakhs /-