}

Modernization Work On Turnkey Basis Under Rdss In Varanasi City, varanasi-Uttar Pradesh

Government Departments has published Modernization Work On Turnkey Basis Under Rdss In Varanasi City. Submission Date for this Tender is 27-09-2024. Building Work Tenders in varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

44464489
Corrigendum : Modernization Work On Turnkey Basis Under Rdss In Varanasi City
Open Tender
Indian
Uttar Pradesh
Varanasi
27-09-2024

Tender Documents

Tender Details

Modernization Work on Turnkey Basis Under Rdss In Varanasi City. - Supply for ( 2 X 5 MVA) New 33/11 KV Substation- SCADA Compatible asper technical specifications, scope of works and approved drawings 2 Supply& installation, testing and commissioning of5 MVA Power Transformer 3 Construction of Power Transformer Plinth of size 3.46x4.46 Mtr. having 0.5 Mtr. below ground level and 0.4 Mtr. above ground level. 4 Supply & Erectionof 100 KVA, 11/0.415 kV, 3 ph, 50 Hz, ONAN,Aluminiumwound,(Level -2) CRGO core, outdoor typeStation Transformer Completely filled with transformer oil asper technical specifications. 5 Supply & Erectionof hot dip Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per ISfor all structural members. As per TS 6 Supply & Erection ofGI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS. 7 Supply & Erecrionof 36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 8 Construction ofPlinth & foundationfor33 kv VCB 9 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,400-200/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 10 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,200-100/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 11 Construction of Plinth & foundationfor33 kV Single Phase CT (3 Nos.) 12 Supply & Erectionof 36 kV, 1-Phase, 33kV/110 volt, Single coreoutdoor type Potential Transformer including accessories etc., complete as per technical specifications.( 1 set=3 no) As per TS 13 Construction ofPlinth & foundation for 33 kV Single PT (3 Nos.) 14 36kV, indoor, Control & Relay panel alongwith E/F & O/C,Mimic Diagram,Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc. complete as per approved drawings & TS: 15 Supply & Erection of33 kV feeder Panel (without diffirential relays) complete As per TS. 16 Supply& Erectionof 33 kV Double Transformer Panel (withdiffirential relay and 5/1 A auxillary CT)complete As per TS . 17 Supply & Erectionof 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch) 18 Supply & Erection of36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch) 19 Construction ofPlinth & foundation for 33 kV isolator 20 Supply & Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete(1 set= 3 Nos.) 21 Construction ofPlinth & foundation for 33 kVLA 22 Supply & Erectionof of9kV, 10kA, 1-ph Station Class LighteningArrester complete (1 Set = 3 Nos.) 23 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit BreakerforIncomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase ,withNumerical Relays & accessories complete as per specifications for transformer breaker protectionwith earth fault, overcurrent . 24 Supply & Erection of12 kV, 1600 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit Breakerforalong with 12 kV, 1-Phase, 25kA, 600-300/5-5 A,3 Nos indoor type Current Transformer, control panel for Bus couplar and required accessories, A-meter, Numerical Relays & accessories complete as per specifications for Bus Coupler protectionwith earth fault, overcurrent . 25 Supply & Erectionof 12 KV 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 26 Supply & Erectionof 24V, 150 AHPb(Lead) Acid battery,withcabinet specifications. 27 Supply & Erection of 24V, 150 AH.Float-cum-Boost Battery Chargerfor230V,1 phase, 50 Hz AC Input Supply as per technical specifications. 28 Supply& Erectionof 24V DCDB complete in all respect suitable for 20 nos.of DC circuit for smooth operation of DC supplyas per technical specifications. 29 Supply & Erection of 415V AC Distribution Board/Panel of sheet stealenclosed cubical floor mounting type for catering auxiliary power supply for Suitable100 KV T/F of the substaion etc. complete 30 Supply & Erection of ACSR Panther Conductor for Bus-Bars & Jumpers/Droppers/Terminations 31 Earthing & Grounding conductor as per Approved Electrical Layoutfor each sub- station with 32 Supply & Erection of75 x 8 mm GI flat. 33 Supply & Erection of 50 x 6 mm GI flat. 34 Supply & Erectionof32 mm dia MS rod 6 m long for earth mat 35 Supply & Erection of40 mm dia.,3000 mm long GI pipe earthelectrode as per Technical Specification 36 33 KV and 11 KV Insulator - Pin, Post and Disc insulators along with G.I. Pin, Hardware & Accessories suitable for Panther conductors as per Technical secifications(All the materials shallbe MShot dip galvanised) 37 Supply & Erectionof 33 KV Post Insulator (1 Set = 2 Nos of 22 KV) 38 Construction ofPlinth & foundation for 33 kVPost Insulator 39 Supply & Erection of 33 KV Disc InsulatorInsulator(1 Set = 4 Nos Disc Insulator 70 KN) 40 Supply & Erection ofHardware fitting for 33 KV Disc Insulator (B&S Type 70 KN) 41 Supply & Erection of33 KV Polymer Pin Insulator with Nut & Bolt . 42 Supply & Erection ofBimetalic Clamps , Al. Connectors, Al. tape etc. complete in all respect as required. 43 Supply & Erectionof Station Lighting System (External) 120 Watt, LEDwith proper illuminationcomplete for switchyard,main gate and sub-station boundry including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. all complte as per applicable TS and approved drawing. (minimum 8 nos on Lighting Poles & 8 nos on structure & control room building ) 44 Supply & Erectionof Station Lighting System (internal) with proper illumination complete forcontrol room building, Incharge room, Battery room, Store room, Washroom, Guard room, portico etc.including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc.and Celling Fan , wall Fan & exhaust fan (Total 8 nos.) all complte as per applicable TS and approved drawing. 45 Supply & Erection of Tool & Plant: Gum Boot- 2 pair, Hand Gloves- 2 pair, Insulated Plier- 2 nos., D E spanner set- 2 sets, Slide Wrench 8 & 12 2 nos each, Torch (Flash Light) 4 cell- 2 nos, Earth Tester - 1 no, Insulation Megger (hand operated) 2500 V-1 no, Tong Tester (Digital)- 1 no, Discharge Rod (1 Set=3 Nos)- 2 Sets, Rubber mat (1.25 Thick) for laying in front of all panels in control room completely 46 Supply & ErectionFire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for controlroom, CO 2 Type of 4.5Kg Capacity4 nos for Control Room, Fire bucketswith Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings 47 11 KV, XLPE, Power cable, aluminiumconductor, stranded 48 Supply of11kv3Cx 300 sqmm (armoured) Cable 49 Supply of11 kv 3Cx 185 sqmm (armoured) Cable 50 Supplyof11 kv3Cx70 Sqmm (armoured) Cable 51 Laying of 11 KV U/G cable includnig cost of sand and bricks 52 Heat Shrinkable jointing kit suitable for 11 kV XLPE 3x300 Sq.mm. cable size 53 Supply & Erection ofHeat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE outdoor 54 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE Indoor 55 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 56 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE outdoor 57 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE Indoor 58 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x70 Sq.mm. cable size 59 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE outdoor 60 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE Indoor 61 Control Cable 62 Supplyof4x2.5 mm sq. 63 Supply ofof 2x2.5 mm sq. 64 Supply of LT Power Cable 3.5Cx95 sq. mm . 65 Laying of Control Cable 66 Furniture items as required 67 Office table Godrej make 68 Office chair Godrej make 69 Godrej Storwel (Almirah) standard size. 70 11kV Feeder Double Pole structure on 11kV STP alongwith fitting 71 Supply & Erectionof 11 Mtr. long Steel Tubulor Pole SP- (410 SP 55). 72 Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 73 Suplly &Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt. 74 Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt. 75 Supply & Erection of Earthing of pole by GI earthing rod of 18x2500 mm. and 6 SWG earthing wire etc. 76 S/S name board (SMC) with stand. 77 Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS 78 Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift:All kinds of soil 79 Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil : 80 Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth. 81 Deduct for not watering the excavated earth for banking 82 Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 83 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 84 CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 85 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 86 CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 87 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 88 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 89 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete 90 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts 91 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 92 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide 93 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 94 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges 95 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 96 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 97 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) 98 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level. 99 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 100 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 101 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 102 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) 103 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand) 104 First class brick laid dry in foundation and plinth as incircular soakpit walls of one brick thickness and 2.0 to 3.0M depthincluding cutting moulding bricks as required including cost ofall materials labour and T&P complete. 105 S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit). 106 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 107 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces 108 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panescomplete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 109 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 110 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 111 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 112 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 113 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 114 Fixing and grouting of trench edging in proper level andalignment including cost of all labour, and T&P etc. required forproper completion of the work but excluding cost of C.C. (labour rates only) . 115 Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge. 116 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. 117 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm 118 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 119 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 120 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 121 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 122 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 123 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 124 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 125 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC 126 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick 127 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 128 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 129 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 130 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 131 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3) 132 Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as. 133 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4) 134 S/F Angle/Batten Holder. 135 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1) 136 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)(DSR E&M 2022 1.27.2) 137 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3) 138 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4) 139 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5) 140 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6) 141 S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit. 142 Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect. 143 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6) 144 Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1) 145 Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make 146 Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect. 147 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. 148 S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 149 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12) 150 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. 151 Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. 152 Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required forproper completion of work. 153 Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc.(CSI No. 19.28) 154 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil 300 mm dia 155 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia 156 Providing and fixing of 150 mm dia PVC pipeof 6 Kg/sqcmwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25) 157 Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. 158 Supply and fixing of 110mm dia PVC. bail plug of heavy qualityincluding all labour material & T&P. 159 Supply and fixing of 160mm dia PVC top plug of heavy qualityincluding all labour material & T&P. 160 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 161 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 162 Supply & fixing of steel wire rope forsubmersible pump including cost of labour, T&P and material required for completion of work.(CSI No. 19.34) 163 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms 165 Supply & Installation ofsubmersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work.(CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH 166 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes 167 Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser.(CSI No. 19.31)a) for 1 HP pump set single phase 168 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 169 S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect. 170 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes 171 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes 172 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes 173 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore 174 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 175 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 176 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 177 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length 178 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms 179 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 180 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 181 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 182 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989 183 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 184 Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 185 Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etcrequired for proper completion of the work.c)110 mm dia. 186 Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etcrequired for proper completion of the work c) 110 mm dia. 187 Providing and fixing SWR, PVC ( Finolex or equivalent )Coupler including cost of all materials, labour and T&P etcrequired for proper completion of the work. c) 110 mm dia. 188 Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 189 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 190 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 191 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 192 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 193 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 194 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 195 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 196 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 197 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 198 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 199 Supply of Automatic Capacitor Bank as per approved drawings, technical specifications and scope of work (1.98 MVAr With APFC Panel) 200 Supply & Erection of12.65 kV, 1980 kVAr, 3-Phase, 50 C/s, housed in Outdoor Type CRCA panel, Capacitor bank having two variable step of 792 Kvar & one Variable steps of 396 kVAr. Bank shall be complete with Capacitor units of 264/132 kVAr,Aluminium busbars, Epoxy insulators, HT HRC fuse,Surge suppressor etc.with details as follows-(1 )11 KV Alumuniumwound ,Dry type series reactor(a)0.528 KVAr for 792 KVAr step-6 nos. (b)0.264 KVAr for 396 kVAr step-3 nos. (2) 11 kV, 3-Phase Indoor Dry Type RVT-1 nos. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor-3 nos. (4) Indoor Type Automatic Control Unit-1 No. (5) IP 55, outdoor CRCA cubicle panel for accommodating capacitors, series reactors, vacuum contactor, surge supressor etc., along with FRP canopy-1 No. 201 Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(1.98 MVAr HT Capacitor bank) 202 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(1.98 MVAr HT Capacitor bank) 203 Supply & Erectionof Indoor Type Automatic Control Unit(1.98 MVAr HT Capacitor bank) 204 Supply & Erectionof IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(1.98 MVAr HT Capacitor bank) 205 Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(1.98 MVAr HT Capacitor bank) 206 Supply & Layingof 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(1.98 MVAr HT Capacitor bank) 207 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(1.98 MVAr HT Capacitor bank) 208 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit outoor(1.98 MVAr HT Capacitor bank) 209 Supply & Erection 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(1.98 MVAr HT Capacitor bank) 210 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(1.98 MVAr HT Capacitor bank) 211 Casting of Civil foundation(1.98 MVAr HT Capacitor bank) 212 Cable trench for laying of power/control cables.(1.98 MVAr HT Capacitor bank) 213 Supply for ( 1X 10 MVA) New 33/11 KV Substation- SCADA Compatible asper technical specifications, scope of works and approved drawings 214 Supply&installation, testing and commissioning of10 MVA Power Transformer 215 Construction of Power Transformer Plinth of size 3.46x4.46 Mtr. having 0.5 Mtr. below ground level and 0.4 Mtr. above ground level. 216 Supply & Erectionof 100 KVA, 11/0.415 kV, 3 ph, 50 Hz, ONAN,Aluminiumwound,(three star rated) CRGO core, outdoor typeStation Transformer Completely filled with transformer oil asper technical specifications. 217 Supply & Erectionof hot dip Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per ISfor all structural members. As per TS 218 Supply & Erection ofGI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS. 219 Supply & Erecrionof 36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 220 Construction ofPlinth & foundationfor33 kv VCB 221 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,400-200/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 222 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,200-100/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 223 Construction of Plinth & foundationfor33 kV Single Phase CT (3 Nos.) 224 Supply & Erectionof 36 kV, 1-Phase, 33kV/110 volt, Single coreoutdoor type Potential Transformer including accessories etc., complete as per technical specifications.( 1 set=3 no) 225 Construction ofPlinth & foundation for 33 kV Single PT (3 Nos.) 226 36kV, indoor, Control & Relay panel alongwith E/F & O/C,Mimic Diagram,Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc. complete as per approved drawings & TS: 227 Supply & Erection of33 kV feeder Panel (without diffirential relays) complete. 228 Supply& Erectionof 33 kV Transformer Panel (withdiffirential relay and 5/1 A auxillary CT) complete. 229 Supply & Erectionof 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch) 230 Supply & Erection of36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch) 231 Construction ofPlinth & foundation for 33 kVIsolator 232 Supply & Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete(1 set= 3 Nos.) 233 Construction ofPlinth & foundation for 33 kV LA 234 Supply & Erectionof of9kV, 10kA, 1-ph Station Class LighteningArrester complete (1 Set = 3 Nos.) 235 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit BreakerforIncomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase , with Numerical Relays & accessories complete as per specifications for transformer breaker protectionwith earth fault, overcurrent . 236 Supply & Erectionof 12 KV 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 237 Supply & Erectionof 24V, 150 AHPb(Lead) Acid battery,as per technical specifications. 238 Supply & Erection of 24V, 150 AH.Float-cum-Boost Battery Charger with full wave rectification for230V,1 phase, 50 Hz AC Input Supply as per technical specifications. 239 Supply& Erectionof 24V DCDB complete in all respect suitable for 20 nos.of DC circuit for smooth operation of DC supplyas per technical specifications. 240 Supply & Erection of 415V AC Distribution Board/Panel of sheet stealenclosed cubical floor mounting type for catering auxiliary power supply for Suitable100 KV T/F of the substaion etc. complete 241 Supply & Erection of ACSR Panther Conductor for Bus-Bars & Jumpers/Droppers/Terminations 242 Earthing & Grounding conductor as per Approved Electrical Layoutfor each sub- station with 243 Supply & Erection of75 x 8 mm GI flat. 244 Supply & Erection of 50 x 6 mm GI flat. 245 Supply & Erectionof32 mm dia MS rod 6 m long for earth mat 246 Supply & Erection of40 mm dia.,3000 mm long GI pipe earthelectrode as per Technical Specification 247 33 KV and 11 KV Insulator - Pin, Post and Disc insulators along with G.I. Pin, Hardware & Accessories suitable for Panther conductors as per Technical secifications(All the materials shallbe MShot dip galvanised) 248 Supply & Erectionof 33 KV Post Insulator (1 Set = 2 Nos of 22 KV) 249 Construction of Plinth & foundation for 33 kVPost Insulator 250 Supply & Erection of 33 KV Disc InsulatorInsulator(1 Set = 4 Nos Disc Insulator 70 KN) 251 Supply & Erection ofHardware fitting for 33 KV Disc Insulator (B&S Type 70 KN) 252 Supply & Erection of33 KV Polymer Pin Insulator with Nut & Bolt . 253 Supply & Erection ofBimetalic Clamps , Al. Connectors, Al. tape etc. complete in all respect as required. 254 Supply & Erectionof Station Lighting System (External) 120 Watt, LEDwith proper illuminationcomplete for switchyard,main gate and sub-station boundry including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. all complte as per applicable TS and approved drawing. (minimum 8 nos on Lighting Poles & 8 nos on structure & control room ) 255 Supply & Erectionof Station Lighting System (internal) with proper illumination complete forcontrol room building, Incharge room, Battery room, Store room, Washroom, Guard room, portico etc.including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc.and Celling, wall Fan & exhast fan (Total 8 nos.) all complte as per applicable TS and approved drawing. 256 Supply & Erection of Tool & Plant: Gum Boot- 2 pair, Hand Gloves- 2 pair, Insulated Plier- 2 nos., D E spanner set- 2 sets, Slide range 8 & 12 2 nos each, Torch (Flash Light) 4 cell- 2 nos, Earth megger- 1 no, Insulation Megger (hand operated) 1000 V-1 no, Tong Tester (Digital)- 1 no, Discharge Rod (1 Set=3 Nos)- 6 Sets, Rubber mat (1.25 Thick) for laying in front of all panels in control room completely 257 Supply & ErectionFire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for controlroom, CO 2 Type of 4.5Kg Capacity4 nos for Control Room, Fire bucketswith Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings 258 11 KV, XLPE, Power cable, aluminiumconductor, stranded 259 Supply of11kv3Cx 300 sqmm (armoured) Cable 260 Supply of11 kv 3Cx 185 sqmm (armoured) Cable 261 Supplyof11 kv3Cx70 Sqmm(armoured) Cable 262 Laying of 11 KV U/G cable includnig cost of sand and bricks 263 Heat Shrinkable jointing kit suitable for 11 kV XLPE 3x300 Sq.mm. cable size 264 Supply & Erection ofHeat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE outdoor 265 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE Indoor 266 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 267 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE outdoor 268 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE Indoor 269 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x50 Sq.mm. cable size 270 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x35 Sq. mm. XLPE outdoor 271 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x35 Sq. mm. XLPE Indoor 272 Control Cable 273 Supplyof4x2.5 mm sq. 274 Supply ofof 2x2.5 mm sq. 275 Supply of LT Power Cable 3.5Cx95 sq. mm. 276 Laying of Control Cable 277 11kV Feeder Double Pole structure on 11kV STP alongwith fitting (as per Annex-9) 278 Supply & Erectionof 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55) 279 Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 280 Suplly &Erection of 11KV TPMO switch with fixing clamps 281 Supply & Erection of 11 KV fuse set with fixing clamps 282 Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 283 S/S name board (SMC) with stand. 284 Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS 285 Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift:All kinds of soil 286 Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil : 287 Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth. 288 Deduct for not watering the excavated earth for banking 289 Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 290 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 291 CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 292 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 293 CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 294 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 295 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 296 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete 297 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts 298 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 299 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide 300 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 301 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges 302 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 303 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 304 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) 305 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level. 306 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 307 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 308 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 309 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) 310 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand) 311 First class brick laid dry in foundation and plinth as incircular soakpit walls of one brick thickness and 2.0 to 3.0M depthincluding cutting moulding bricks as required including cost ofall materials labour and T&P complete. 312 S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit). 313 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 314 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces 315 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panescomplete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 316 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 317 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 318 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 319 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 320 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 321 Fixing and grouting of trench edging in proper level andalignment including cost of all labour, and T&P etc. required forproper completion of the work but excluding cost of C.C. (labour rates only) . 322 Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge. 323 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. 324 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm 325 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 326 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 327 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 328 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 329 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 330 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 331 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 332 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC 333 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick 334 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 335 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 336 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 337 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 338 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3) 339 Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as. 340 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4) 341 S/F Angle/Batten Holder. 342 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1) 343 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)(DSR E&M 2022 1.27.2) 344 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3) 345 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4) 346 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5) 347 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6) 348 S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit. 349 Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect. 350 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6) 351 Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1) 352 Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make 353 Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect. 354 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. 355 S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 356 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12) 357 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. 358 Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. 359 Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required forproper completion of work. 360 Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc.(CSI No. 19.28) 361 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil 300 mm dia 362 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia 363 Providing and fixing of 150 mm dia PVC pipeof 6 Kg/sqcmwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25) 364 Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. 365 Supply and fixing of 110mm dia PVC. bail plug of heavy qualityincluding all labour material & T&P. 366 Supply and fixing of 160mm dia PVC top plug of heavy qualityincluding all labour material & T&P. 367 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 368 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 369 Supply & fixing of steel wire rope forsubmersible pump including cost of labour, T&P and material required for completion of work.(CSI No. 19.34) 370 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 371 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms 372 Supply & Installation ofsubmersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work.(CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH 373 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes 374 Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser.(CSI No. 19.31)a) for 1 HP pump set single phase 375 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 376 S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect. 377 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes 378 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes 379 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes 380 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore 381 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 382 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 383 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 384 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length 385 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms 386 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 387 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 388 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 389 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989 390 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 391 Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 392 Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etcrequired for proper completion of the work.c)110 mm dia. 393 Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etcrequired for proper completion of the work c) 110 mm dia. 394 Providing and fixing SWR, PVC ( Finolex or equivalent )Coupler including cost of all materials, labour and T&P etcrequired for proper completion of the work. c) 110 mm dia. 395 Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 396 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 397 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 398 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 399 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 400 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 401 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 402 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 403 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 404 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 405 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 406 3.96 MVAr With APFC Panel As per TS 407 Supply & Erection of 12.65 kV, 3960 kVAr, 3-Phase, 50 C/shoused in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set 408 Supply &Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank) 409 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank) 410 Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank) 411 Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank) 412 Supply& Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank) 413 Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank) 414 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank) 415 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank) 416 Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank) 417 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(3.96 MVAr HT Capacitor bank) 418 Casting of Civil foundation(3.96 MVAr HT Capacitor bank) 419 Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank) 420 Supply for ( 2X 10 MVA) New 33/11 KV Substation- SCADA Compatible asper technical specifications, scope of works and approved drawings 421 Supply& installation, testing and commissioning of10 MVA Power Transformer 422 Construction of Power Transformer Plinth of size 3.46x4.46 Mtr. having 0.5 Mtr. below ground level and 0.4 Mtr. above ground level. 423 Supply & Erectionof 100 KVA, 11/0.415 kV, 3 ph, 50 Hz, ONAN,Aluminiumwound,(three star rated) CRGO core, outdoor typeStation Transformer Completely filled with transformer oil asper technical specifications. 424 Supply & Erectionof hot dip Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per IS:4759 for all structural members. 3.5mm spring washers are to be used under each structural steel shall conform to IS 2026. All weld shall be 6mm filled weld unless specified otherwise.Anchor plate shall be of relevant IS 425 Supply & Erection ofGI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS. All bolts & nuts, washers etc. shall be galvanizedas per IS:4759. 3.5mm spring washers are to be used under each nut shall conform to IS 2026.All nuts and bolts shall be of property class 5.6 of IS 1367. Plain washers shall be as per IS 2016 & spring washers shall be IS: 3063 and foundation bolts, shall be of relevant IS 426 Supply & Erecrionof 36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 427 Construction ofPlinth & foundation for 33 kVVCB. 428 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,400-200/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 429 Supply& Erectionof 36kV, 1-Phase, 25kA/3 seconds,200-100/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 430 Construction ofPlinth & foundation for 33 kVCT . 431 Supply & Erectionof 36 kV, 1-Phase, 33kV/110 volt, Single coreoutdoor type Potential Transformer including accessories etc., complete as per technical specifications.( 1 set=3 no) 432 Construction ofPlinth & foundation for 33 kVPT 433 36kV, indoor, Control & Relay panel alongwith E/F & O/C,Mimic Diagram,Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc. complete as per approved drawings & TS: 434 Supply & Erection of33 kV feeder Panel (without diffirential relays) complete. 435 Supply& Erectionof 33 kV Double Transformer Panel (withdiffirential relay and 5/1 A auxillary CT)complete As per TS. 436 Supply & Erectionof 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch) 437 Supply & Erection of36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch) 438 Construction ofPlinth & foundation for 33 kVIsolator . 439 Supply & Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete(1 set= 3 Nos.) 440 construction ofPlinth & foundation for 33 kVLA 441 Supply & Erectionof of9kV, 10kA, 1-ph Station Class LighteningArrester complete (1 Set = 3 Nos.) 442 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit BreakerforIncomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase , Numerical Relays & accessories complete as per specifications for transformer breaker protectionwith earth fault, overcurrent . 443 Supply & Erection of12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit Breakerforalong with 12 kV, 1-Phase, 25kA, 600-300/5-5 A,3 Nos indoor type Current Transformer, control panel for Bus couplar and required accessories, A-meter, Numerical Relays & accessories complete as per specifications for Bus Coupler protectionwith earth fault, overcurrent . 444 Supply & Erectionof 12 KV 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 445 Supply & Erectionof 24V, 150 AHPb(Lead) Acid battery As per TS. 446 Supply & Erection of 24V, 150 AH.Float-cum-Boost Battery Chargerfor230V,1 phase, 50 Hz AC Input Supply as per technical specifications. 447 Supply& Erectionof 24V DCDB complete in all respect suitable for 20 nos.of DC circuit for smooth operation of DC supplyas per technical specifications. 448 Supply & Erection of 415V AC Distribution Board/Panel of sheet stealenclosed cubical floor mounting type for catering auxiliary power supply for Suitable100 KV T/F of the substaion etc. complete 449 Supply & Erection of ACSR Panther Conductor for Bus-Bars & Jumpers/Droppers/Terminations 450 Earthing & Grounding conductor as per Approved Electrical Layoutfor each sub- station with 451 Supply & Erection of75 x 8 mm GI flat. 452 Supply & Erection of 50 x 6 mm GI flat. 453 Supply & Erectionof32 mm dia MS rod 6 m long for earth mat 454 Supply & Erection of40 mm dia.,3000 mm long GI pipe earthelectrode as per Technical Specification 455 33 KV and 11 KV Insulator - Pin, Post and Disc insulators along with G.I. Pin, Hardware & Accessories suitable for Panther conductors as per Technical secifications(All the materials shallbe MShot dip galvanised) 456 Supply & Erectionof 33 KV Post Insulator (1 Set = 2 Nos of 22 KV) 457 Construction of Plinth & foundation for 33 kVPost Insulator 458 Supply & Erection of 33 KV Disc InsulatorInsulator(1 Set = 4 Nos Disc Insulator 70 KN) 459 Supply & Erection ofHardware fitting for 33 KV Disc Insulator (B&S Type 70 KN) 460 Supply & Erection of33 KV Polymer Pin Insulator with Pin 461 Supply & Erection ofBimetalic Clamps , Al. Connectors, Al. tape etc. complete in all respect as required. 462 Supply & Erectionof Station Lighting System (External) 120 Watt, LEDwith proper illuminationcomplete for switchyard,main gate and sub-station boundry including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. all complte as per applicable TS and approved drawing. (minimum 8 nos on Lighting Poles & 8 nos on structure & control room ) 463 Supply & Erectionof Station Lighting System (internal) with proper illumination complete forcontrol room building, Incharge room, Battery room, Store room, Washroom, Guard room, portico etc.including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc.and Celling, wall Fan & exhast fan (Total 8 nos.) all complte as per applicable TS and approved drawing. 464 Supply & Erection of Tool & Plant: Gum Boot- 2 pair, Hand Gloves- 2 pair, Insulated Plier- 2 nos., D E spanner set- 2 sets, Slide range 8 & 12 2 nos each, Torch (Flash Light) 4 cell- 2 nos, Earth megger- 1 no, Insulation Megger (hand operated) 1000 V-1 no, Tong Tester (Digital)- 1 no, Discharge Rod (1 Set=3 Nos)- 6 Sets, Rubber mat (1.25 Thick) for laying in front of all panels in control room completely 465 Supply & ErectionFire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for controlroom, CO 2 Type of 4.5Kg Capacity4 nos for Control Room, Fire bucketswith Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings 466 11 KV, XLPE, Power cable, aluminiumconductor, stranded 467 Supply of11kv3Cx 300 sqmm (armoured) Cable 468 Supply of11 kv 3Cx 185 sqmm (armoured) Cable 469 Supplyof11 kv3Cx70 Sqmm (armoured) Cable 470 Laying of 11 KV U/G cable includnig cost of sand and bricks 471 Heat Shrinkable jointing kit suitable for 11 kV XLPE 3x300 Sq.mm. cable size 472 Supply & Erection ofHeat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE outdoor 473 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE Indoor 474 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 475 Supply & Erectionof Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE outdoor 476 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE Indoor 477 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x70 Sq.mm. cable size 478 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE outdoor 479 Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE Indoor 480 Control Cable 481 Supplyof4x2.5 mm sq. 482 Supply ofof 2x2.5 mm sq. 483 Supplyof LT Power Cable 3.5Cx95 sq. mm. 484 Laying of Control Cable 485 11kV Feeder Double Pole structure on 11kV STP alongwith fitting (as per Annex-9) 486 Supply & Erectionof 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55) 487 Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 488 Suplly &Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt. 489 Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt. 490 Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 491 S/S name board (SMC) with stand. 492 Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS 493 Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift:All kinds of soil 494 Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil : 495 Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth. 496 Deduct for not watering the excavated earth for banking 497 Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 498 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 499 CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 500 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 501 CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 502 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 503 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 504 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete 505 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts 506 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 507 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide 508 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 509 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges 510 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 511 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 512 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) 513 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level. 514 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 515 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 516 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 517 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) 518 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand) 519 First class brick laid dry in foundation and plinth as incircular soakpit walls of one brick thickness and 2.0 to 3.0M depthincluding cutting moulding bricks as required including cost ofall materials labour and T&P complete. 520 S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit). 521 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 522 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces 523 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panescomplete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 524 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 525 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 526 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 527 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 528 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 529 Fixing and grouting of trench edging in proper level andalignment including cost of all labour, and T&P etc. required forproper completion of the work but excluding cost of C.C. (labour rates only) . 530 Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge. 531 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. 532 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm 533 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 534 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 535 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 536 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 537 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 538 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 539 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 540 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC 541 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick 542 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 543 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 544 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 545 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 546 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3) 547 Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as. 548 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4) 549 S/F Angle/Batten Holder. 550 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1) 551 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)(DSR E&M 2022 1.27.2) 552 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3) 553 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4) 554 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5) 555 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6) 556 S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit. 557 Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect. 558 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6) 559 Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1) 560 Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make 561 Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect. 562 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. 563 S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 564 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12) 565 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. 566 Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. 567 Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required forproper completion of work. 568 Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc.(CSI No. 19.28) 569 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil 300 mm dia 570 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia 571 Providing and fixing of 150 mm dia PVC pipeof 6 Kg/sqcmwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25) 572 Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. 573 Supply and fixing of 110mm dia PVC. bail plug of heavy qualityincluding all labour material & T&P. 574 Supply and fixing of 160mm dia PVC top plug of heavy qualityincluding all labour material & T&P. 575 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 576 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 577 Supply & fixing of steel wire rope forsubmersible pump including cost of labour, T&P and material required for completion of work.(CSI No. 19.34) 578 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 579 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms 580 Supply & Installation ofsubmersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work.(CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH 581 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes 582 Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser.(CSI No. 19.31)a) for 1 HP pump set single phase 583 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 584 S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect. 585 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes 586 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes 587 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes 588 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore 589 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 590 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 591 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 592 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length 593 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms 594 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 595 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 596 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 597 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989 598 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 599 Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 600 Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etcrequired for proper completion of the work.c)110 mm dia. 601 Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etcrequired for proper completion of the work c) 110 mm dia. 602 Providing and fixing SWR, PVC ( Finolex or equivalent )Coupler including cost of all materials, labour and T&P etcrequired for proper completion of the work. c) 110 mm dia. 603 Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 604 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 605 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 606 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 607 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 608 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 609 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 610 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 611 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 612 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 613 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 614 3.96 MVAr With APFC Panel As per TS 615 Supply & Erection of 12.65 kV, 3960 kVAr, 3-Phase, 50 C/shoused in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set 616 Supply &Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank) 617 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank) 618 Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank) 619 Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank) 620 Supply& Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank) 621 Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank) 622 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank) 623 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank) 624 Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank) 625 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(3.96 MVAr HT Capacitor bank) 626 Casting of Civil foundation(3.96 MVAr HT Capacitor bank) 627 Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank) 628 Supply for New 33/11 KV Indoor GIS Type Substation- SCADA Compatible asper technical specifications, scope of works and approved drawings 629 Supply & installation, testing and commissioning of 10 MVA 33/11 kV Transformer with all complete assesories as per TS 630 Construction of Plinth & Foundation for10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS( On As it is where it is basis) 631 Supply& Erection of 33 KV GIS Panels with 2 line bays, 2 transformer bays, 1 bus coupler bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. 632 Supply & Erection of 11 KV GIS Panels with 6 line bays, 2 transformer bays, 1 station transformer bay & 1 bus coupler bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section. 633 Supply& Erection of 24 V, 150AH,Pb(Lead) Acidtype battery setscomplete. 634 Supply& Erecion of Float-cum-boost battery charger (SMPS based ) with full wave , full control rectification, 50Hz input voltage for charging 24V, 150 AH Battery alongwith DCDB, connectors etc. complete and connection with 24 V , 150 AH Battery set and single phase AC input supply. 635 Supply& Erection of 415V AC Distribution Board/Panel of sheet stealenclosed cubical floor mounting type for catering auxiliary power supply of the substaion etc. complete 636 Supply & Erectionof 100KVA, 11 kV/0.415 kv Station Transformer alongwith allaccessories as per TS. 637 Supply& Erection of40mm dia 3000mm long GI Pipe (Medium Grade) earth electrodes & other accessories for treated earth erection is including of Excavation and other associated activities as per TS. 638 Supply& Erection of 75x6 mm Galvanized flat for raiser for earthing as per TS 639 Supply& Erection of 30 KV, 1 Phase, 10KA LA with all accessories as per TS. 640 Supply& Erection of 9 KV, 1 Phase, 10KA LA with all accessories as per TS. 641 Supply& Layingof 3Cx300 sqmm. 33 KV cable (Panel to Transformer- 1 Run) with cable tray. 642 Supply& Laynibg of 3Cx400 sqmm. 11 KV cable (Panel to Transformer- 2 Run) with cable tray. 643 Suppy & Laying of LT Power Cable 3.5Cx95 sq. mm. 644 Supply& Laying of Control Cable of 2 core 2.5 sq. mm copper cable with cable tray and associated items 645 Supply& Laynibgof Control Cable of 4 core 2.5 sq. mm copper cable with cable tray associated items 646 Supply & Laying of Control Cable of 10 core 2.5 sq. mm copper cable with cable tray associated items 647 Supply of Fire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for controlroom, CO 2 Type of 4.5Kg Capacity4 nos for Control Room, Fire bucketswith Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings 648 Supply& Erection of Synthetic Rubber mats as per IS 15652 in control room 2.5 mm thik 649 Supply& Erectionof 11 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 300 sqmm 650 Supply& Erectionof 33 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 400 sqmm(Incoming) 651 Supply & Erection of 11KV XLPE Cable(3x300 sq.mm.) Heat Shrinkable Jointing kit outdoor 652 Supply & Erection of 33KV XLPE Cable(3x400 sq.mm.) Heat Shrinkable Jointing kit outdoor 653 Supply& Erection of Complete lighting system for control room building,main gate and substation boundary including fans as per detailed Technical Specifications. 654 Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS 655 Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift:All kinds of soil 656 Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil : 657 Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth. 658 Deduct for not watering the excavated earth for banking 659 Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 660 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 661 CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 662 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 663 CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 664 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 665 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 666 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete 667 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts 668 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 669 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide 670 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like 671 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges 672 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 673 FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 674 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) 675 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level. 676 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 677 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 678 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 679 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand) 680 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand) 681 First class brick laid dry in foundation and plinth as incircular soakpit walls of one brick thickness and 2.0 to 3.0M depthincluding cutting moulding bricks as required including cost ofall materials labour and T&P complete. 682 S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit). 683 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 684 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces 685 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panescomplete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 686 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 687 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 688 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 689 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 690 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 691 Fixing and grouting of trench edging in proper level andalignment including cost of all labour, and T&P etc. required forproper completion of the work but excluding cost of C.C. (labour rates only) . 692 Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge. 693 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. 694 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm 695 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 696 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 697 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 698 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 699 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 700 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 701 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 702 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC 703 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick 704 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 705 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 706 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 707 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 708 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3) 709 Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as. 710 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4) 711 S/F Angle/Batten Holder. 712 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1) 713 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)(DSR E&M 2022 1.27.2) 714 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3) 715 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4) 716 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5) 717 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6) 718 S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit. 719 Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect. 720 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6) 721 Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1) 722 Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make 723 Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect. 724 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. 725 S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 726 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12) 727 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havellsor equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. 728 Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. 729 Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required forproper completion of work. 730 Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc.(CSI No. 19.28) 731 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil 300 mm dia 732 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia 733 Providing and fixing of 150 mm dia PVC pipeof 6 Kg/sqcmwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25) 734 Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work. 735 Supply and fixing of 110mm dia PVC. bail plug of heavy qualityincluding all labour material & T&P. 736 Supply and fixing of 160mm dia PVC top plug of heavy qualityincluding all labour material & T&P. 737 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 738 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 739 Supply & fixing of steel wire rope forsubmersible pump including cost of labour, T&P and material required for completion of work.(CSI No. 19.34) 740 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 741 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms 742 Supply & Installation ofsubmersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work.(CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH 743 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes 744 Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser.(CSI No. 19.31)a) for 1 HP pump set single phase 745 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 746 S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect. 747 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes 748 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes 749 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes 750 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore 751 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 752 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 753 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 754 Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length 755 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms 756 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 757 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 758 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 759 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989 760 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 761 Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 762 Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etcrequired for proper completion of the work.c)110 mm dia. 763 Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etcrequired for proper completion of the work c) 110 mm dia. 764 Providing and fixing SWR, PVC ( Finolex or equivalent )Coupler including cost of all materials, labour and T&P etcrequired for proper completion of the work. c) 110 mm dia. 765 Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 766 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 767 Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia. 768 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 769 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 770 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 771 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 772 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 773 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 774 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. 775 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c &) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’slimit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v) 776 Augmentationl Power Transformers( 5 to 10 MVA) SCADA Compatible asper technical specifications, scope of works and approved drawings 777 Supply &installation, testing and commissioning of10 MVA33/11 kV, 3 ph, 50 Hz, ONAN,Cu Wound, Outdoor Conventional type PowerTransformer with off load tap charger ( completely field with oil) as per TS 778 MS Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per IS:4759 for all structural members. 3.5mm spring washers are to be used under each structural steel shall conform to IS 2026. All weld shall be 6mm filled weld unless specified otherwise.Anchor plat shall be of relevant IS 779 GI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS. All bolts & nuts, washers etc. shall be galvanizedas per IS:4759. 3.5mm spring washers are to be used under each nut shall conform to IS 2026.All nuts and bolts shall be of property class 5.6 of IS 1367. Plain washers shall be as per IS 2016 & spring washers shall be IS: 3063 and foundation bolts, shall be of relevant IS 780 Supply & Erection of 36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 781 Construction ofPlinth & foundation for 33 kVVCB 782 Supply & Erectionof 36kV, 1-Phase, 25kA/3 seconds,200-100/1-1 Amps ( having 3 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications. 783 Supply& Erectionof 33 kV SingleTransformer Panel (withdiffirential relay and 5/1 A auxillary CT)complete As per TS . 784 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit BreakerforIncomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type 3 core Current Transformer, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase ,Numerical Relays & accessories complete as per specifications for transformer breaker protectionwith earth fault, overcurrent . 785 Supply & Erection of 12 KV, 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 786 11 KV, XLPE, Power cable, aluminiumconductor, stranded 787 Supply of 3Cx 300 sqmm (armoured) 788 Supply of 3Cx 185 sqmm (armoured) 789 Laying of 11 KV U/G cable includnig cost of sand and bricks 790 Cable termination kit suitable for termination in transformer cable box/breaker panel/ outdoor 11 KV terminals complete with all accessories etc 791 Supply & ErectionTermination kit3Cx 300 sqmm outdoor 792 Supply & ErectionTermination kit3Cx 300 sqmm indoor 793 Supply & Erection of Termination kit3Cx 185 sqmmoutdoor 794 Supply & Erection of Termination kit3Cx 185 sqmm Indoor 795 Control Cable 796 Supplyof4x2.5 mm sq. 797 Supply ofof 2x2.5 mm sq. 798 Laying of Control Cable 799 Dismantaling &Transportation from existing site to Store,Installation, Erection, Testing and Commisiioning of 5/8 MVAPower Transformerswithsuitable Clamps, Connectors, bolts nuts and washers of Brassetcas required with 2 sets each of body & neutral earthing with 50x8 mm GS Strip as per TS completely required for commissioning. 800 Modification of existing Power Transformer foundation required for installation and commissionig of augmented 5/10 MVA Power Transformers completely as per TS. (As per requirement) 801 Additional 5 MVA & 10 MVA Power Transformers SCADA Compatible asper technical specifications, scope of works and approved drawings 802 Supply &installation, testing and commissioning of 5 MVA Power Transformer 803 Supply &installation, testing and commissioning of 10 MVA Power Transformer 804 Construction of Plinth & Foundation for 10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS( On As it is where it is basis) 805 Construction of Plinth & FoundationFoundation for 5 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS( On As it is where it is basis) 806 Supply & Erecrionof 36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 807 Construction ofPlinth & foundation for 33 kVVCB 808 Supply & Erection of36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch) 809 Supply & Erection of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch) 810 Construction ofPlinth & foundation for 33 kVIsolator 811 Supply & Erectionof 303kV, 10kA, 1-ph Station Class Lightening Arrester complete(1 set= 3 Nos.) 812 Construction ofPlinth & foundation for 33 kVLA 813 Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds,400-200/1-1 Amps ( having 3 secondery, core), 1 set = 3 Nos outdoortype Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 814 Construction ofPlinth & foundation for 33 kVCT 815 Supply & Erection of 33 kV Transformer Panel (withdiffirential relay and 5/1 A auxillary CT)complete 816 Supply & Erection 11 KV VCB Switchgears 817 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit BreakerforIncomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase , , Numerical Relays & accessories complete as per specifications for transformer breaker protectionwith earth fault, overcurrent . 818 Supply & Erection of 12 kV, 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuit Breakerforalong with 12 kV, 1-Phase, 25kA, 600-300/5-5 A,3 Nos indoor type Current Transformer, control panel for Bus couplar and required accessories, A-meter, Numerical Relays & accessories complete as per specifications for Bus Coupler protectionwith earth fault, overcurrent . 819 Supply & Erectionof 12 KV 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 820 11 KV 3 Core Al. XLPE Insulated Cable 821 Supply of 3x300mm sq. 822 Supplyof 3x185mm sq. 823 Laying of 11 KV U/G cable includnig cost of sand and bricks 824 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x300 Sq.mm. cable size 825 Supply & ErectionTermination kit3Cx 300 sqmm outdoor 826 Supply & Erection of Termination kit3Cx 300 sqmm Indoor 827 Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 828 Supply & ErectionTermination kit3Cx 185sqmm outdoor 829 Supply & Erection of Termination kit3Cx 185 sqmm Indoor 830 Control Cable 831 Supply & Laying 4x2.5 mm sq. 832 Supply & Laying 2x2.5 mm sq. 833 Earthing of substation complete as per specification 834 Supply & Erection of75 x 8 mm GI flat. 835 Supply & Erection of 50 x 6 mm GI flat. 836 Supply & Erectionof32 mm dia MS rod 6 m long for earth mat 837 Supply & Erection of40 mm dia.,3000 mm long GI pipe earthelectrode as per Technical Specification 838 11kV Feeder Double Pole structure on 11kV STP alongwith fitting 839 Supply & Erectionof 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55) 840 Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 841 Suplly &Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt. 842 Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt. 843 Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 844 conversion of Existing substations to GIS substations with Increasing capacity and One no E-House additional substation establish SCADA compatibility( 2x10 MVA -2Nos ,3x10 MVA-1 No & 4x10 MVA2 nos 845 Supply & installation & Commissioning of 10 MVA 33/11 kV Transformer with all complete assesories as per TS 846 Construction of Plinth &Foundation for 10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS 847 Supply & Erection of 33 KV GIS incomer Panels , all complete with numerical relays, facility for data transmission and remote control . Ap per TS 848 Supply & Erection of 33 KV GIS outgoing Panels , all complete with numerical relays, facility for data transmission and remote control .As per TS 849 Supply& Erectionof 33 KV GIS bus couplerPanels , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc.As per TS 850 Supply & Erection of 11 KV GIS incomerPanels with , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section. 851 Supply & Erection of 11 KV GISOutgoing Panels with , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section. 852 Supply & Erection of 11 KV GISBus couplerPanels with , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section. 853 Supply & Erection of40mm dia 3000mm long GI Pipe (Medium Grade) earth electrodes & other accessories as per TS. 854 Supply& Erectionof 60x8 mm Galvanized flat for raiser for earthing as per TS 855 Supply& Layingof 3Cx400 sqmm. 33 KV cable (Panel to Transformer- 1 Run) with cable tray. 856 Supply& Layingof 3Cx300 sqmm. 11 KV cable (Panel to Transformer- 2 Run) with cable tray. 857 Supply & Laying of Control Cable of 2 core 2.5 sq. mm copper cable with cable tray and associated items 858 Supply& Laying of Control Cable of 4 core 2.5 sq. mm copper cable with cable tray associated items 859 Supply & Laying of Control Cable of 10 core 2.5 sq. mm copper cable with cable tray associated items 860 Supply & Erectionof 11 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 300 sqmm 861 Supply & Erection of 33 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 400 sqmm(Incoming) 862 Supply & Erection of 33KV XLPE Cable (3x400 Sq.mm.)outdoor Heat Shrinkable Termination kit boxes mounted. 863 Supply & Erection of 11KV XLPE Cable (3x300 Sq.mm.)outdoor Heat Shrinkable Termination kit boxes mounted. 864 Dismentling of existing 33 KV&11 Panelincluding storage, handling, insurance, loading, unloading, transportation to store of Utility as per the direction of Engineer-in-charge with propoer accounting as per the inventory. 865 Dismentling of existing 33 KVisolator,CT ,PT &CBwith structure including storage, handling, insurance, loading, unloading, transportation to store of Utility as per the direction of Engineer-in-charge with propoer accounting as per the inventory. 866 Dismentling of existing 33 KVBay with structure including storage, handling, insurance, loading, unloading, transportation to store of Utility as per the direction of Engineer-in-charge with propoer accounting as per the inventory. 867 Nagar Nigam E-House Substation establish SCADA compatibility ( 2x10MVA) 868 Supply , installation, testing and comrnissiong of 10 MVA Power Transformer,33/11 kV, 3 ph, 50 Hz, ONAN,Cu Wound, Outdoor Conventional type PowerTransformer with off load tap charger ( completely field with oil) as per TS perthe specifications. The bansformer shall be complete with all accessories shall be provided with cable box termination arrangement on HV & LV side. 869 Supply, installation, testing and commissioning of Pre-fabricated Containerized Substation shall made of GI (2mm thick for load bearing and 1.5mm for non load bearing members) having IP 54 enclosurewith 50mm rockwool 2hr Fire rated thermal insulation 870 Supply, installation, testing and commissioning of Pre-fabricated Containerized Substation shall made of GI (2mm thick for load bearing and 1.5mm for non load bearing members) having IP 54 enclosurewith 50mm rockwool 2hr Fire rated thermal insulationa. 33kV Indoor Primary GIS as per TS ( 2 Incomer VCB +1 Bus Caupler +2 Outgoing VCB for 10 MVA Transformer) — 1Setb. llkV Indoor Primary GIS as per TS ( 2 Incomer VCB + 1Bus Caupler +6 Outgoing VCB)-1 Setc. 1No Entry/Exit door Provision for E-House. 1 door shall be suitable for equipment entry from inside onlyd. Battery Bank 48VDC150 AH - 1 Sete. Dual Float cum Boost Battery Charger suitable for 48 V DC, 80 A ( Auto and Manual)-lNo.f. ACDB - 1 Setg. DCDB- 1 seth. Fire Alarm System & Fire Extinguisher(Co2 type) - 1 Seti. AC system (N+1) & AC Control panel - 1 Setj. LT power & control cabling within the container equipmentk. Station earthing grid internal to Container.l. Lightning protection for Metalliccontainer .m. Ilumination System normal & emergency (48V DC) lighting, Lighting Panels, switches and sockets.n. Survillance system complete in all respects(with data backup facilty for 60days)camera 6nos i.e. 2Nos for covering entrance, 2Nos for internal area & 2Nos for acess control system withacess cardo. Metallic container with doors with access control, access platforms.p. Supply of termination kits for 33kV & llKV GIS & termination of cables at site.q. Rubber Insulation mats — As required.Size of Container should be 15 meter X 4.5Meter with sufficient provision for acess (max)The enclosure shall containall the indoor equipments like 33KV GIS, llKV GIS, ACDB,DCDB,RTU panel, RTCC panel, banery chargers, Lightining system, Fire safety system as per the tender specifications.The Container should have followingA)33kv Indoor Gas Insulated Switchgear Panel 1250 A, 31.5KA/3sec which consists of 2 No Line feeder,1 Bus Caupler, 2No transformer feeder( 9 Panels GIS BOARD) as per the enclosed Technical specifications.Internal arc tested panel as per IAC AFLR 31.5 kA for 1sec.TheGIS shall be 3 phase combined and single bus type. CT ratio shall be 400/1+1+1+1 A and PT shall be 33000/sqrt3 Volt/110/sqrt3 Volt.Vacuum Circuit breaker, numerical relays having IEC 61850 protocoland multifunctional metersfor SCADA compatibility as per atmched technical specification.All the GIS panels shall be operated and monitored through SCADA. B)11kv Indoor Gas Insulated Switchgear Panel1250A, 25 KA/3sec which consists of 1No Line feeder,2 No Substation transformerfeeder, 6 Nos Outgoing feeders(9 Panel GIS BOARD)as per the enclosed Technical specifications.Internal arc tested panel as per IAC AFLR 25 kA for1 sec.The GIS shall be 3 phase combined and single bus type. CT ratio for the incomer shall be ***/1+1+1 Aand PT shall be 11000/sqrt3 Volt/110/sqrt 3 Volt. Vacuum Circuit breaker, numerical relays having IEC 61850 protocoland multifunctional metersfor SCADA compatibility as per attached technical specification.All the GIS panels shall be operated and monitored through SCADA.C) Remote Terminal Unit Panel with Ethernet Switch and interposing relay DI/DO as per the mentioned GIS panels list which includes Master Remote Terminal unit, RTU Control Panel & Cabling between RTU and GIS Panel boards. 871 Supply & Erection of 100KVA, 11 kV/0.415 kv Station Transformer alongwith allaccessories as per TS. 872 Supply & Erection of40mm dia 3000mm long GI Pipe (Medium Grade) earth electrodes & other accessories for treated earth erection is including of Excavation and other associated activities as per TS. 873 Supply & Erection of 60x8 mm Galvanized flat for raiser for earthing as per TS 874 Suplly & Erection of 30 KV, 1 Phase, 10KA LA with all accessories as per TS. 875 Supply & Erection of 9 KV, 1 Phase, 10KA LA with all accessories as per TS. 876 Supply & Erection of 3Cx400 sqmm. 33 KV cable (Panel to Transformer- 1 Run) with cable tray. 877 Supply & Erection of 3Cx300 sqmm. 11 KV cable (Panel to Transformer- 2 Run) with cable tray. 878 Supply & Laying of Control Cable of 2 core 2.5 sq. mm copper cable with cable tray and associated items 879 Supply & Laying of Control Cable of 4 core 2.5 sq. mm copper cable with cable tray associated items 880 Supply & Layingof Control Cable of 10 core 2.5 sq. mm copper cable with cable tray associated items 881 Supply & ErectionFire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for controlroom, CO 2 Type of 4.5Kg Capacity4 nos for Control Room, Fire bucketswith Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings 882 Supply & Erectionof Synthetic Rubber mats as per IS 15652 in control room 2.5 mm thik 883 Supply and Erection of 33 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 400 sqmm 884 Supply and erection of 11 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 300 sqmm(Incoming) 885 Supply and Erection of 33KV XLPE Cable (3x400 Sq.mm.)outdoor Heat Shrinkable Termination kit boxes mounted with transformer. 886 Supply and Erection of 11KV XLPE Cable (3x300 Sq.mm.)outdoor Heat Shrinkable Termination kit boxes mounted with transformer. 887 Construction of Plinth & Foundation for 10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS 888 Supply & Erecton Complete Lighting System for switchyard(High Mast 16 meter winch mechanism) along with provision of Solar Lighting at main gate and sub-station boundary including fans as per detailed TS.(For Onestations) 889 Constructionof BoundaryWall (includingsupply of material) with fixing of MS angle & Barbed wire fencing(around Transformer and wherever required) all along the boudary wall includingPlasteringand Distempering(both sides),supplyand fixing of main gate - complete with painting (with double coating of metallic primer and paint)etc.all as per approved drawing &TS (Measurementfor this purpose will include length of the gate along the boundarywall). 890 Civils works(including supply ofmaterial) for 33/1 lkV containerised substation including foundation, including RCC cable trench with precast trench covers for incoming and outgoing cables(Both 33KV & llKV ) and other related works to complete installation, testing, commissioning of substation included. 891 Development of land includes filling of land upto two feet above thr adjoining road, construction of wash room cum toilet with septic and overhead water tanks,drainage system,drinking water supply(Borewell with submersible pump set complete),sewerage system of substation, construction of approch road(5mtr wide) etc. as per approveddrawing or as per instruction of Engineer -in- Charge (including supply of material) 892 Development of land includes filling of land upto two feet above thr adjoining road, construction of wash room cum toilet with septic and overhead water tanks,drainage system,drinking water supply(Borewell with submersible pump set complete),sewerage system of substation, construction of approch road(5mtr wide) etc. as per 893 Constriction (including supply of all material) of RCC cable trench along with pre-cast RCC trench cover, Brick work whenever required all complete as per approved drawing and TS outside the conbol room building - 0.5 Mtrs wide bench. 894 11kV Feeder Double Pole structure on 11kV STP alongwith fitting (as per Annex-9) 895 Supply & Erectionof 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55) 896 Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 897 Suplly &Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt. 898 Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt. 899 Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 900 3.96 MVAr With APFC Panel As per TS 901 Supply & Erection of 12.65 kV, 3960 kVAr, 3-Phase, 50 C/shoused in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set 902 Supply &Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank) 903 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank) 904 Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank) 905 Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank) 906 Supply& Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank) 907 Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank) 908 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank) 909 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank) 910 Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank) 911 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(3.96 MVAr HT Capacitor bank) 912 Casting of Civil foundation(3.96 MVAr HT Capacitor bank) 913 Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank) 914 Supply & Erection for New 33 KV Lineon 9 mtr PCC pole with DOG conductor asper technical specifications, scope of works and approved drawings 915 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 916 Eerection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 917 Supply & Erection of 9 m PCC Poles - (PCC Pole as per state practice) 918 Supply & Erection of Stone Pad(300x300x75mm) 919 Excavtion and grouting of 9 m PCC Poles with Base pad including Cement concretingfoundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications (state practices of PCC pole, stone to be used) 920 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for erection of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 921 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 922 Supply & Erection of 33 KV danger board 923 Supply & Erection of GI Barbed wire 12 SWG 924 Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings 925 Supply & Erection of 33 KV 10 KN Polymer Pin Insulators 926 8 SWG GI Coil 115 turns (1.85 Kg) 927 Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 928 Grouting of complete stay set with0.3 cumt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 929 Supply & Erection of 6 SWG GI wire 930 Supply & Erection of 8 SWG GI wire 931 Supply & Erection of PG Clamp for Dog to Dog conductor 932 Supply & Erection for New 33 KV Lineon 11 mtr steel tubular pole with DOG conductor asper technical specifications, scope of works and approved drawings 933 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 934 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 935 Supply & Erection of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 936 Excvation & Grouting 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cum + 0.014 cum (Muffing) 937 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for erection of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 938 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 939 Supply & Erection of 33 KV danger board 940 Supply & Erection of GI Barbed wire 12 SWG 941 Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings (B&S Type) 942 Supply & Erection of 33 KV 10 KN Polymer Pin Insulators 943 8 SWG GI Coil 115 turns (1.85 Kg) 944 Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 945 Erection of complete stay set with0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 946 Supply & Erection of 6 SWG GI wire 947 Supply & Erection of 8 SWG GI wire 948 Supply & Erectionof PG Clamp for Dog to Dog conductor 949 Supply & Pinting of silver paint 950 Supply & Painting of red oxidepaint 951 Supply & Erection for New 33 KV Line on 13 mtr steel tubular pole with DOG conductor asper technical specifications, scope of works and approved drawings 952 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 953 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 954 Supply & Erection of 13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) As per TS 955 Excvation & Grouting of 13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 956 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 957 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 958 Supply & Erection of 33 KV danger board 959 Supply & Erection of GI Barbed wire 12 SWG 960 Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings (B&S Type) 961 Supply & Erection of 33 KV 10 KN Polymer Pin Insulators 962 8 SWG GI Coil 115 turns (1.85 Kg) 963 Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 964 Erection of complete stay set with0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 965 Supply & Erection of 6 SWG GI wire 966 Supply & Erection of 8 SWG GI wire 967 Supply & Erection of PG Clamp for Dog to Dog conductor 968 Supply & Painting of silver paint 969 Supply & Paintingof red oxidepaint 970 Supply & Erection of 33 KV Under ground cable as per technical specification, approved drawings and scope of work. 971 Supplyof 3CX300 Sqmm 33 KV XLPE Armored Cable . 972 Digging of trench for laying of Double circuit 33KV 3x300 sq.mm XLPE cable and making of trench for two nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone/Precast slab (PuVVNL 33 KV HT engraved) after laying of cable into the trench including providing and fixing cable route marker. 973 Digging of trench for laying of Single circuit 33KV 3x300 sq.mm XLPE cable and making of trench for two nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone/Precast slab (PuVVNL 33 KV HT engraved) after laying of cable into the trench including providing and fixing cable route marker. 974 Laying of Singlecircuit of 3x300 Sq. mm 33KV XLPE insulated cable underground in cable trenchesand earth filling of trenches 975 Laying of 33 KV 3x300 Sqmm. XLPE Cable underground through HDPEPipe at 1050 mm below the ground surface.(by HDD method) for road crossing including providing and fixing cable route marker. 976 Supplyof 160 mm dia. HDPE pipe. 977 Laying of 160 mm dia. HDPE pipe by Horizontal drilling by HDD method as per site condition, for underground piping (trenchless) for road crossing. 978 Supply & Erection ofof Heat Shrinkable Jointing Straight Through Kitfor 33 KV 3x300 sq. mm XLPE Cable 979 Supply & Erection ofof Heat Shrinkable Jointing Straight Through Kitfor 33 KV 3x300 sq. mm XLPE Cable 980 Supply & Erectionof G.I. pipe 150mmwith clamp and nut & bolts 981 Hoisting of cable on double pole with the help of cable clamp with N&B of suitable size 982 Supply & Erection of 33 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 983 Supply & Erection, testing & commissioning of33 kV LINEFORUNDER GROUND RAILWAY CROSSING (300 Mtr) BY 2 Nos (INCLUDING ONE SPARE)3Cx300 Sqmm XLPE Armoured Cable USING 150MM DIA GI PIPES (grade A for underground laying and grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS,LUGS, 4 Nos GI 3-Meters LONG pipe, EARTHING, 8 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS, JUMPERING , AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 984 Supply & Erection of 11 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 985 Supply & Erection, testing & commissioning of 33 kV LINEFORUNDER GROUND Highway CROSSING (200 Mtr) BY 2 Nos (INCLUDING ONE SPARE)3Cx300 Sqmm XLPE Armoured Cable USING 150MM DIA GI PIPES (grade A for underground laying and grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS,LUGS, 4 Nos GI 3-Meters LONG pipe, EARTHING, 8 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS, JUMPERING , AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 986 Supply & Erection For Construction of new 11 KV line on 8.5 mtr PCC pole with weasel conductor asper technical specifications, scope of works and approved drawings 987 Supplyof 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel 988 Erection of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel 989 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 990 Supply & Erection of Stone Pad(300x300x75mm) 991 Erection of 8.5 m/180 Kgs PCC Poles withBase stone pad including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications(state practices of PCC pole and base plate/stone to be used) 992 Supply & Erection of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 993 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 994 Supply & Erection of 11 KV danger board 995 Supply & Erection of GI Barbed wire 12 SWG 996 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 997 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 998 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 999 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1000 StayGrouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1001 Supply & Erection of 6 SWG GI wire 1002 Supply & Erection of 8 SWG GI wire 1003 Supply & Erection of PG Clamp for Weasel to Weasel conductor 1004 Supply & Erection For Construction of new 11 KV line on 11mtr STP pole with Rabbit conductor asper technical specifications, scope of works and approved drawings 1005 Supplyof 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit 1006 Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit 1007 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1008 Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1009 Supply & Erection forPre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1010 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1011 Supply & Erection of 11 KV danger board 1012 Supply & Erection of GI Barbed wire 12 SWG 1013 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1014 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1015 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1016 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1017 Stay Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1018 Supply & Erection of 6 SWG GI wire 1019 Supply & Erection of 8 SWG GI wire 1020 Supply & Erection of PG Clamp for Rabbit to Rabbit conductor 1021 Supply & Painting of silver paint 1022 Supply & Painting of red oxidepaint 1023 Supply & Erection For Construction of new 11 KV line on 11mtr STP pole with Dog conductor asper technical specifications, scope of works and approved drawings 1024 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 1025 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog 1026 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1027 Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1028 Supply & Erection of New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1029 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1030 Supply & Erection of 11 KV danger board 1031 Supply & Erection of GI Barbed wire 12 SWG 1032 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings (B&S Type) 1033 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with Nut & Bolt. 1034 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1035 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1036 Stay Grouthing 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1037 Supply & Erection of 6 SWG GI wire 1038 Supply & Erection of 8 SWG GI wire 1039 Supply & Erection of PG Clamp for Dog to Dog conductor 1040 Supply & Paintingof silver paint 1041 Supply & Painting of red oxidepaint 1042 Supply & Erection For Construction of new 11 KV line on 8.5mtr PCC pole with Rabbit conductor asper technical specifications, scope of works and approved drawings 1043 Supplyof 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit 1044 Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit 1045 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1046 Supply & Erection of Stone Pad(300x300x75mm) 1047 Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1048 Supply & Erectionof New3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1049 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1050 Supply & Erection of 11 KV danger board 1051 Supply & Erection of GI Barbed wire 12 SWG 1052 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1053 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with Nut & Bolt. 1054 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1055 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1056 Stay Grouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1057 Supply & Erection of 6 SWG GI wire 1058 Supply & Erection of 8 SWG GI wire 1059 Supply & Erection of PG Clamp for Rabbit to Rabbit conductor 1060 Supply & Erection of 11 KV Lineunderground 3*185 XLPE Cableensuring statutory clearances as required as per technical specification, approved drawings and scope of work 1061 Supply of 3Cx185 Sqmm 11 KV XLPE Armored Cable 1062 Digging of trench for laying of double circuit 11KV 3x185 sq.mm XLPE cable and making of trench for two nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone slab /Precast slab (PuVVNL 11 KV HT engraved) after laying of cable into the trench including providing and fixing cable route marker. 1063 Digging of trench for laying of Single circuit 11KV 3x185 sq.mm XLPE cable and making of trench for one nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone slab after laying of cable into the trench. 1064 Laying of single circuit of 3x185 Sq. mm 11KV XLPE insulated cable underground in cable trenchesand earth filling of trenches 1065 Laying of 11 KV 3Cx185 sq.mm XLPE Cable underground through HDPEPipe at 950 mm below the ground surface. (by HDD method) including providing and fixing cable route marker. 1066 Supply& Erection of 110 mm dia. HDPE pipe . 1067 Supply & Erection of Heat Shrinkable Jointing Kit Straight throughfor 11 KV 3x185 sq. mm XLPE Cable 1068 Supply & Erection of Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable 1069 Supply & Erectionof G.I. pipe 110 mm diawithclamps, Nut and Bolts. 1070 Hoisting of cable on double pole with the help of cable clamp with N&B of suitable size 1071 Supply & Erection For new 11 KV line on 11 mtr STP with insulated covered (50 sq mm) conductorasper technical specifications, scope of works and approved drawings 1072 SupplyOf Insulated ACS Covered Conductor Size equivalent to Rabbit conductor. 1073 Erection of Insulated ACS Covered Conductor Size equivalent to Rabbit conductor. 1074 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1075 Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1076 Supply & Erection of New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1077 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1078 Supply & Erection of 11 KV danger board 1079 Supply & Erection of GI Barbed wire 12 SWG 1080 Supply & Erection Tension clamp/Dead Clamp/Anchoring Clamp with Piercing Connectors suitable for MVCC. 1081 Supply& Erectionof IPC for CC to CC Connection suitable for MVCC 1082 Supply & Erection of IPC/Connector for Bare to CC Connection suitable for MVCC 1083 Supply & Erection of Suspension/Insulated Ties 1084 Supply & Erection of Mid Span Jointing Kit 1085 Supply & Erection ofIPC with Aluminium bail for earthing 1086 Supply & Erectionof Termination Kits 1087 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1088 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1089 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1090 Supply & Erection of 6 SWG GI wire 1091 Supply & Erection of 8 SWG GI wire 1092 Supply & Paintingof silver paint 1093 Supply & Painting of red oxidepaint 1094 Supply & Erection For new 11 KV line on 3x70 sqmm XLPE cable asper technical specifications, scope of works and approved drawings 1095 Supplyof 11 Kv Line on 3x70 sqmm XLPE Cable 1096 Erection of 11 Kv Line on 3x70 sqmm XLPE Cable 1097 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1098 Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1099 Supply & Erection of new 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1100 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1101 Supply & Erection of 11 KV danger board 1102 Supply & Erection of GI Barbed wire 12 SWG 1103 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1104 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1105 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1106 Supply & Erection of 6 SWG GI wire 1107 Supply & Erection of 8 SWG GI wire 1108 cable Jointing kit for 11 kvLine 70 sqmm 1109 Supply & Painting of silver paint 1110 Supply & Painting of red oxidepaint 1111 Supply & Erection of 11 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 1112 Supply & Erection , testing & commissioningfor 11 KV lineunder ground Railway crossing with 2 nos (Including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) using 150mm dia GI pipes (grade A for underground laying and grade B for pole support), Outdoor heat shrinkable cable jointing kit, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES,CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 1113 Supply & Erection of 11 LV Line underground Highway crossing ensuring statutory clearancesas required as per technical specification, approved drawings and scope of work 1114 Supply & Erection , testing & commissioning of 11 KV LINEFORUNDER GROUND Highway CROSSING BY 2 Nos (INCLUDING ONE SPARE) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) USING 160 mm HDPE pipe at road crossing and 150MM DIA GI PIPES (gradeB for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES, 7/20 GI wire, CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 1115 New Distribution Transformer25 KVA 11/433 KV - Supply 1116 supply & Erectionof 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1117 Concreting of supports with Grounting f 0.44 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1118 Supply & Erectionof new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel,Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete asper TS & approved drawings. 1119 Supply & Erectionof hot dip galvanized MS Nuts, Bolts with Washers as per TS 1120 Supply& Erection of 11 KV 5 KN Polymer Pin Insulators 1121 Supply& Erection of 11 KV45 KN polymer Disc insulatoras per TS. 1122 Supply& Erectionof suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductoras per TS. 1123 Supply& Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1124 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1125 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1126 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1127 Supply& Erection of 6 SWG GI wire for earthing as per TS 1128 Supply &Erectionof Barbed GI wire 12 SWG 1129 Supply& Erection of PG Clamp suitable for ACSRRabbit conductor as per TS 1130 Supply of 11 KV danger board 1131 Supply& Erection of 11 KV, 3-Pole, 3-Ph, 400A, TPMO as per TS 1132 SupplyErection of 11 KV, 3-Ph, 400A, DO Fuse as per TS 1133 Supply of 3-Phase, 11/0.4 kV, 25KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS BIS Level - 2 1134 Supply & Erection of LT Distribution box with suitable rating MCCB for incomer & MCCBfor two no outgoing feeder suitable for 25 kVA,Distribution Transformer alongwith energymeter suitable for pole mounting as per TS 1135 Supply& Erectionof 9 kV, 5 KA porcelain housing Lightning Arrestorwith Disconnector for DTas per TS. (3 nos=1 set) 1136 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1137 Supply& Erection of Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1138 Supply& Erection of 1-Core 70 mm2, Al. LT XLPE Cable as per TS 1139 New Distribution Transformer63 KVA 11/433 KV - Supply 1140 supply& Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1141 Concreting of supports with Grounting f 0.44 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1142 Supply& Erectionof new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel,Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete asper TS & approved drawings. 1143 Supply& Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1144 Supply& Erection of 11 KV 5 KN Polymer Pin Insulators 1145 Supply& Erection of 11 KV45 KN polymer Disc insulatoras per TS. 1146 Supply& Erection of suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductoras per TS. 1147 Supply& Erectoin of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1148 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1149 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1150 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1151 Supply & Erectoin of 6 SWG GI wire for earthing as per TS 1152 Supply& Erection of Barbed GI wire 12 SWG 1153 Supply& Erection of PG Clamp suitable for ACSR Weaselconductor as per TS 1154 Supply & Erection of 11 KV danger board 1155 Supply& Erection of 11 KV, 3-Pole, 3-Ph, 400A, A B Switch as per TS 1156 Supply & Erection of 11 KV, 3-Ph, 400A, DO Fuse as per TS 1157 Supply& Erection of 3-Phase, 11/0.4 kV, 63 KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS BIS Level - 2 1158 Supply& Erection of of LT Distribution box with suitable rating MCCB for incomer & MCCBfor two no outgoing feeder suitable for 63 kVA,Dist1ibution Transformer alongwith energymeter suitable for pole mounting as per TS 1159 Supply& Erection of of 9 kV, 5 KA porcelain housing Lightning Arrestorwith Disconnector for DTas per TS. (3 nos=1 set) 1160 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1161 Supply & Erectionof Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1162 Supply& Erection of 1-Core 240 mm2, Al. LT XLPE Cable as per TS 1163 New Distribution Transformer 100 KVA 11/433 KV - Supply 1164 supply& Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1165 Concreting of supports with Grounting f 0.44 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1166 Supply& Erection of new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel,Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete asper TS & approved drawings. 1167 Supply& Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1168 Supply& Erection of 11 KV 5 KN Polymer Pin Insulators 1169 Supply& Erection of 11 KV45 KN polymer Disc insulatoras per TS. 1170 Supply& Erection of suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductoras per TS. 1171 Supply& Erectoin of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1172 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1173 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1174 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1175 Supply & Erectoin of 6 SWG GI wire for earthing as per TS 1176 Supply& Erection of Barbed GI wire 12 SWG 1177 Supply& Erection of PG Clamp suitable for ACSR Weaselconductor as per TS 1178 Supply & Erection of 11 KV danger board 1179 Supply& Erectionof 11 KV, 3-Pole, 3-Ph, 400A, A B Switch as per TS 1180 Supply & Erection of 11 KV, 3-Ph, 400A, DO Fuse as per TS 1181 Supply& Erection of 3-Phase, 11/0.4 kV, 100 KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS BIS Level - 2 1182 Supply & Erectionof LT Distribution box with suitable rating MCCB for incomer & MCCBfor two no outgoing feeder suitable for 100 kVA,Dist1ibution Transformer alongwith energymeter suitable for pole mounting as per TS 1183 Supply &Erectionof 9 kV, 5 KA porcelain housing Lightning Arrestorwith Disconnector for DTas per TS. (3 nos=1 set) 1184 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm . 1185 Supply & Erection Earthing Arrangement ofchemical pipe size of 40x3000 mm. a etc. 1186 Supply& Erection of 1-Core 240 mm2, Al. LT XLPE Cable as per TS 1187 New Distribution Transformer 250 KVA 11/433 KV - Supply 1188 Supply& Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1189 Concreting of supports with Grounting f 0.44 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1190 Supply& Erectionof new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel,Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete asper TS & approved drawings. 1191 Supply& Erectionof hot dip galvanized MS Nuts, Bolts with Washers as per TS 1192 Supply& Erection of 11 KV 5 KN Polymer Pin Insulators 1193 Supply& Erection of 11 KV45 KN polymer Disc insulatoras per TS. 1194 Supply& Erection of suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductoras per TS. 1195 Supply& Erectoin of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1196 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1197 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1198 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1199 Supply & Erectoin of 6 SWG GI wire for earthing as per TS 1200 Supply& Erection of Barbed GI wire 12 SWG 1201 Supply& Erection of PG Clamp suitable for ACSR Weaselconductor as per TS 1202 Supply & Erection of 11 KV danger board 1203 Supply& Erectionof 11 KV, 3-Pole, 3-Ph, 400A, A B Switch as per TS 1204 Supply & Erection of 11 KV, 3-Ph, 400A, DO Fuse as per TS 1205 Supply& Erection of 3-Phase, 11/0.4 kV, 250KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS BIS Level - 2 1206 Supply & Erectionof LT Distribution box with suitable rating MCCB for incomer & MCCBfor two no outgoing feeder suitable for 250 kVA,Dist1ibution Transformer alongwith energymeter suitable for pole mounting as per TS 1207 Supply & Erectionof 9 kV, 5 KA porcelain housing Lightning Arrestorwith Disconnector for DTas per TS. (3 nos=1 set) 1208 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1209 Supply & Erectionof Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1210 Supply& Erection of 1-Core 240 mm2, Al. LT XLPE Cable as per TS 1211 Augmentation of 10 kva&16 kva to 25kvaDistribution transformer 1212 Supply & Erection of11/0.433 kV 25kVA Distribution Transformer as per TS. 1213 Supply & Erection ofLT PVC Cable 3.5x70Sq.mm 1214 Supply& Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1215 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1216 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1217 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1218 Supply & Erection of 6 SWG GI wire for earthing as per TS 1219 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1220 Supply & Erection Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1221 Replacment & Transpotation Charge of Existing Distribution Transformer 1222 Augmentation of25 Kva to 63kvaDistribution transformer 1223 Supply & Erection 11/0.433 kV 63kVA Distribution Transformeras per TS. 1224 Supply & Erection LT PVC Cable 3.5x70Sq.mm 1225 Supply& Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1226 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1227 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1228 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1229 Supply& Erection of 6 SWG GI wire for earthing as per TS 1230 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1231 Supply & Erection of Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1232 Replacment & Transpotation Charge of Existing Distribution Transformer 1233 Augmentation of 63 kva to 100 kvaDistribution transformer 1234 Supply & Erection of11/0.433 kV 100kVA Distribution Transformeras per TS. 1235 Supply & Erectionof LT PVC Cable 3.5x150Sq.mm 1236 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1237 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1238 Supply& Erectionof stay guy insulator (1 Nos.),as per TS 1239 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1240 Supply& Erection of 6 SWG GI wire for earthing as per TS 1241 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1242 Supply & Erection of Earthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1243 Replacment & Transpotation Charge of Existing Distribution Transformer 1244 Augmentation of 100 kva & 160 kva to 250 kvaDistribution transformer 1245 Supply & Erection of 11/0.4 KV Distribution Transformer 250 KVA 3 phaseDTR(Copper Winding) 1246 Supply & ErectionofLT PVC cable AI 3.5x400 sq mm 1247 Supply& Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1248 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1249 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1250 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1251 Supply & Erectionof 6 SWG GI wire for earthing as per TS 1252 Supply & ErectionofEarthing for pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1253 Supply & Erection ofEarthingfor Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1254 Replacment & Transpotation Charge of Existing Distribution Transformer 1255 Augmentation of 250 kva to 400 kvaDistribution transformer 1256 Supply & Erectionof 11/0.4 KV Distribution Transformer 400 KVA 3 phaseDTR(Copper Winding) 1257 Supply & Erection ofLT PVC cable AI 1x400 sq mm 1258 Supply & Erection of LT PVC cable AI 1x240 sq mm 1259 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1260 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1261 Supply & Erectionof stay guy insulator (1 Nos.),as per TS 1262 Supply & Erectionof 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1263 Supply& Erection of 6 SWG GI wire for earthing as per TS 1264 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc. 1265 Supply & ErectionofEarthing Arrangement ofchemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc. 1266 Supply & Erection of Al Lug long barrel, off size (LS) 1267 Replacment & Transpotation Charge of Existing Distribution Transformer 1268 Supply & Erection of Trolly Mounted DT- of 400KVA asper technical specifications, scope of works and approved drawings 1269 Supply & Erection of 11/0.415 kV 400 KVA Distribution Transformer Copper Winding. 1270 Supply & Erection of Fabricated Trolley With 4 Tyre wheels to house Transformer with all fixing Arrangement along with fencing and locking mechanism. 1271 Supply & Erection of 3x50 mm² 11KV class XLPE Cable. 1272 Supply & Erection of Heat shrinkable Termination kits suitable for 3x50 mm²Xlpe Cable (out door) including bushing cap. 1273 Supply & Erection of 400 Sq.mm., LT single core `XLPE insulatedun-armoured aluminium conductor cable 1274 Supply & Erection of Protection of DT asper technical specifications, scope of works and approved drawings 1275 Supply & Erection ofAB switch suitable for Distribution Transformer 100 KVA and above 1276 Supply & Erection of DO Fuse set suitable for Distribution Transformer 100 KVA and above 1277 Supply & Erection of LT ACB suitable for Distribution transformers having capacity 250 KVA and above Ap per TS 1278 Supply & Erection of LT Distribution box suitablefor Distribution Transformer upto 250 KVAAs per TS 1279 Supply & Erection of LT Distribution box suitable for Distribution Transformer 400 KVA and above As per TS 1280 Supply & Erection of DT Cable with Lugs & Clamp asper technical specifications, scope of works and approved drawings 1281 Supply & Erection of LT XLPE Insulated Cable 1CX240 Sqmm 1282 Supply & Erection LT XLPE Insulated Cable 1CX400 Sqmm 1283 Supply & ErectionLTXLPE Insulated Cable 1CX630 Sqmm 1284 New LT line on 8.5 mtr PCC pole with AB cable ( (1x16+1x25+1x16) 1285 Supplyof LT Aerial bunchedXLPE cable 1X16 sqmm (Ph) + 1x25 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1286 Eection of LT Aerial bunchedXLPE cable 1X16 sqmm (Ph) + 1x25 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1287 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1288 Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1289 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1290 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1291 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1292 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1293 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1294 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1295 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1296 Supply & Erection of 8 SWG GI wire for earthing as per TS 1297 Supply & Erection of Three phase SMC Distribution box with clamps 1298 Supply & Erectionof 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1299 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1300 Supply of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1301 Supply & Erection of 35 Sqmm PG Clamps as per TS 1302 Supply & Erection of LT Insulation piercing connector 16 -16 sqmm size for phase connection as per TS & approve drawing 1303 Supply & Erection of LT Insulation piercing connector 16-25 sqmm size for phase connection as per TS & approve drawing 1304 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1305 New Lt8.5 Mtr PCCLT Ckt. with AB Cable (3x50+1x35+1x16) 1306 Supplyof LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1307 Erection of LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1308 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1309 Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1310 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1311 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1312 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1313 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1314 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1315 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1316 Supply & Erectionof 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1317 Supply & Erection of 8 SWG GI wire for earthing as per TS 1318 Supply & Erectionof Three phase SMC Distribution box with clamps 1319 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1320 Supply & Erectionof Suspension clamp forLT Aerial Bunched Cable as per TS 1321 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1322 Supply & Erectionof 35 Sqmm PG Clamps as per TS 1323 Supply & Erection of LT Insulation piercing connector 50 -50 sqmm size for phase connection as per TS & approve drawing 1324 Supply & Erection of LT Insulation piercing connector 50-35 sqmm size for phase connection as per TS & approve drawing 1325 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1326 LT line on 8.5 mtr PCC pole with AB cable (3x95+1x70+1x16) 1327 Supplyof LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1328 Erection of LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1329 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1330 Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1331 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1332 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1333 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1334 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1335 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1336 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1337 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1338 Supply & Erection of 8 SWG GI wire for earthing as per TS 1339 Supply & Erection of Three phase SMC Distribution box with clamps 1340 Supply & Erectionof 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1341 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1342 Supply of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1343 Supply & Erection of 35 Sqmm PG Clamps as per TS 1344 Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing 1345 Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing 1346 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1347 LT line with 11 mtr steel tubular pole with AB cable (3x120+1x95+1x16) 1348 Supplyof LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1349 Erection of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1350 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1351 Concreting of supports with Grounting f 0.44 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1352 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1353 Supply & Erectionof hot dip galvanized MS Nuts, Bolts with Washers as per TS 1354 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1355 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1356 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1357 Supply & Erectionof stay guy insulator (1 Nos.),as per TS 1358 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1359 Supply of 8 SWG GI wire for earthing as per TS 1360 Supply & Erection of Three phase SMC Distribution box with clamps 1361 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1362 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1363 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1364 Supply & Erection of 35 Sqmm PG Clamps as per TS 1365 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1366 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1367 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1368 LT line with 11 mtr steel tubular pole with AB cable (3x150+1x120+1x16) 1369 Supplyof LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1370 Erection of LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1371 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1372 Concreting of supports with Grounting f 0.44 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1373 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1374 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1375 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1376 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1377 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1378 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1379 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1380 Supply & Erection of 8 SWG GI wire for earthing as per TS 1381 Supply & Erection of Three phase SMC Distribution box with clamps 1382 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1383 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1384 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1385 Supply & Erection of 35 Sqmm PG Clamps as per TS 1386 Supply & Erection of LT Insulation piercing connector 150 -150 sqmm size for phase connection as per TS & approve drawing 1387 Supply & Erection of LT Insulation piercing connector 150-35 sqmm size for phase connection as per TS & approve drawing 1388 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1389 Strengthening of LT infrastructure by removal of bans and balli in identified areas-Schedule for regularisation of Bas Balli cable for under Varanasi -1as per TS & Approved Drawings. 1390 Supply& Erectionof PCC Pole 8.5 mtr long 1391 Concreting of supports with Grounting of0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 mtr PCC pole Pole of .As per TS. 1392 Supply& Erectionof stone pad (300x300x75mm) 1393 Supply& Erection of STP 9 mtr SP-33 (410 SP 33) 1394 Concreting of supports with Grounting of 0.3 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9 mtr stp pole Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1395 Supply& erectionof Stay set 16x1800 sq mm (including stay rod , turn buckle,I bolt and anchor plate with Guy insulator) 1396 Supply& Erection ofGI Earthing rod (20x2500)mm 1397 Supply& Erectionof Stay wire 7/10 SWG 1398 Supply of & Erection of G.I. wire 5 mm 6 swg 1399 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1400 Supplyof LT A B Cable Size (3x50+1x35+1x16) sq mmwith Bare Massenger 1401 Erection of LT A B Cable Size (3x50+1x35+1x16) sq mmwith Bare Massenger 1402 Supplyof LT A B Cable Size (3x95+1x70+1x16) sq mm with Bare Massenger 1403 Erectionof LT A B Cable Size (3x95+1x70+1x16) sq mm with Bare Massenger 1404 Supply of & Erectionof Suspension clamp with eye hook 1405 Supply of & Erection of Dead end clamp insulated with I hook 1406 Supply of & Erection ofHDG pole Clamp for I-Hook with N&B 1407 Supply of & Erection ofLT Insulation piercing connector 95-35 sqmm / 50-35 sqmm size 1408 Supply of & Erectionof Three phase LT SMC Box with clamp 1409 Supply of & Erection ofPG clamp for Neutral 1410 Supplyof L T XLPE unarmoured Cable of size 4C x 35 sq mm 1411 Erection of L T XLPE unarmoured Cable of size 4C x 35 sq mm 1412 Supply of & Erection of pre insulated compression connector of size 95/50 Sqmm 1413 Supply of & Erection ofStay clamp with N&B 1414 Extra Circuits 8.5 Mtr PCCLT Ckt. with AB Cable (3x50+1x35+1x16) 1415 Supplyof LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1416 Erection of LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1417 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1418 Concreting of supports with Grounting of 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1419 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1420 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1421 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1422 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1423 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1424 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1425 Supply & Erectionof 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1426 Supply & Erection of 8 SWG GI wire for earthing as per TS 1427 Supply & Erectionof Three phase SMC Distribution box with clamps 1428 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1429 Supply & Erectionof Suspension clamp forLT Aerial Bunched Cable as per TS 1430 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1431 Supply & Erectionof 35 Sqmm PG Clamps as per TS 1432 Supply & Erection of LT Insulation piercing connector 50 -50 sqmm size for phase connection as per TS & approve drawing 1433 Supply & Erection of LT Insulation piercing connector 50-35 sqmm size for phase connection as per TS & approve drawing 1434 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1435 Extra Circuits 8.5 Mtr PCCLT Ckt. with AB Cable (3x95+1x70+1x16) 1436 Supplyof LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1437 Erection of LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1438 Supply& Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1439 Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1440 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1441 Supply& Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1442 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1443 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1444 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1445 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1446 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1447 Supply & Erectionof 8 SWG GI wire for earthing as per TS 1448 Supply & Erection of Three phase SMC Distribution box with clamps 1449 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1450 Supply & Erectionof Suspension clamp forLT Aerial Bunched Cable as per TS 1451 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1452 Supply & Erection of 35 Sqmm PG Clamps as per TS 1453 Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing 1454 Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing 1455 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1456 Extra Circuits 9mtr STP PoleLT Ckt. with AB Cable (3x95+1x70+1x16) 1457 Supplyof LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1458 Erection of LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1459 supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980) 1460 Concreting of supports with Grounting f 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 1461 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1462 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1463 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1464 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1465 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1466 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1467 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1468 Supply & Erection of 8 SWG GI wire for earthing as per TS 1469 Supply & Erectionof Three phase SMC Distribution box with clamps 1470 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1471 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1472 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1473 Supply & Erection of 35 Sqmm PG Clamps as per TS 1474 Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing 1475 Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing 1476 Supply & Erectionof LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1477 Extra Circuit LT line with 8.5 Mtr/180 kgs PCC Poles with AB cable (3x120+1x95+1x16) 1478 Supply of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1479 Erection of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1480 Supply & Erectionof 8.5 Mtr/180 kgs PCC Poles as per TS 1481 Concreting of supports with Grountingof0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1482 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1483 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1484 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1485 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1486 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1487 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1488 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1489 Supply & Erection of 8 SWG GI wire for earthing as per TS 1490 Supply & Erection of Three phase SMC Distribution box with clamps 1491 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1492 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1493 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1494 Supply & Erection of 35 Sqmm PG Clamps as per TS 1495 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1496 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1497 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1498 Extra Circuit LT line with 9 mtr steel tubular pole with AB cable (3x120+1x95+1x16) 1499 Supply of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1500 Erectionof LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1501 Supply & Erectionof 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980) 1502 Concreting of supports with Grounting f 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 1503 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1504 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1505 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1506 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1507 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1508 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1509 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1510 Supply & Erection of 8 SWG GI wire for earthing as per TS 1511 Supply & Erection of Three phase SMC Distribution box with clamps 1512 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1513 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1514 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1515 Supply & Erection of 35 Sqmm PG Clamps as per TS 1516 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1517 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1518 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1519 Extra Circuit LT line with 11 mtr steel tubular pole with AB cable (3x120+1x95+1x16) 1520 Supplyof LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1521 Erection of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1522 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1523 Concreting of supports with Grounting f 0.44 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1524 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1525 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1526 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1527 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1528 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1529 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1530 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1531 Supply & Erection of 8 SWG GI wire for earthing as per TS 1532 Supply & Erection of Three phase SMC Distribution box with clamps 1533 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1534 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1535 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1536 Supply & Erection of 35 Sqmm PG Clamps as per TS 1537 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1538 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1539 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1540 Extra Circuit LT line with 11 mtr steel tubular pole with AB cable (3x150+1120+1x16) 1541 Supply of LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1542 Erection of LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1543 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1544 Concreting of supports with Grounting f 0.44 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1545 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1546 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1547 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1548 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1549 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1550 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1551 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1552 Supply & Erection of 8 SWG GI wire for earthing as per TS 1553 Supply & Erection of Three phase SMC Distribution box with clamps 1554 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1555 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1556 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1557 Supply & Erection of 35 Sqmm PG Clamps as per TS 1558 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1559 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1560 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1561 Extra CircuitLT line with 9 mtr steel tubular pole with AB cable (3x150+1x120+1x16) 1562 Supplyof LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1563 Erection of LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1564 Supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980) 1565 Concreting of supports with Grounting f 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 1566 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1567 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1568 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1569 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1570 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1571 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1572 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1573 Supply & Erection of 8 SWG GI wire for earthing as per TS 1574 Supply & Erection of Three phase SMC Distribution box with clamps 1575 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1576 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1577 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1578 Supply & Erection of 35 Sqmm PG Clamps as per TS 1579 Supply & Erection of LT Insulation piercing connector 150 -150 sqmm size for phase connection as per TS & approve drawing 1580 Supply & Erection of LT Insulation piercing connector 150-35 sqmm size for phase connection as per TS & approve drawing 1581 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1582 Extra Circuit LT line with 11 mtr steel tubular pole with AB cable (3x150+1x120+1x16) 1583 Supplyof LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1584 Erection of LT Aerial bunchedXLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1585 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1586 Concreting of supports with Grounting f 0.44 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1587 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1588 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1589 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1590 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1591 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1592 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1593 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1594 Supply & Erection of 8 SWG GI wire for earthing as per TS 1595 Supply & Erection of Three phase SMC Distribution box with clamps 1596 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1597 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1598 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1599 Supply & Erection of 35 Sqmm PG Clamps as per TS 1600 Supply & Erection of LT Insulation piercing connector 150 -150 sqmm size for phase connection as per TS & approve drawing 1601 Supply & Erection of LT Insulation piercing connector 150-35 sqmm size for phase connection as per TS & approve drawing 1602 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1603 Augmentation of LT line with 8.5 Mtr PCC Pole pole with AB cable (3x120+1x95+1x16) 1604 Supplyof LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1605 Erection of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1606 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1607 Concreting of supports with Grountingof0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1608 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1609 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1610 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1611 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1612 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1613 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1614 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1615 Supply & Erection of 8 SWG GI wire for earthing as per TS 1616 Supply & Erection of Three phase SMC Distribution box with clamps 1617 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1618 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1619 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1620 Supply & Erection of 35 Sqmm PG Clamps as per TS 1621 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1622 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1623 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1624 Augmentation of LT line with 9 Mtr STP Pole pole with AB cable (3x120+1x95+1x16) 1625 Supplyof LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1626 Erection of LT Aerial bunchedXLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1627 Supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980) 1628 Concreting of supports with Grounting f 0.270 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 1629 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1630 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1631 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1632 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1633 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1634 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1635 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1636 Supply & Erection of 8 SWG GI wire for earthing as per TS 1637 Supply & Erection of Three phase SMC Distribution box with clamps 1638 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1639 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1640 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1641 Supply & Erection of 35 Sqmm PG Clamps as per TS 1642 Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing 1643 Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing 1644 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1645 Augmentation of LT line on 8.5 mtr PCC pole with AB cable (3x95+1x70+1x16) 1646 Supplyof LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1647 Erection of LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1648 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1649 Concreting of supports with Grountingof0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1650 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1651 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1652 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1653 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1654 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1655 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1656 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1657 Supply & Erection of 8 SWG GI wire for earthing as per TS 1658 Supply & Erection of Three phase SMC Distribution box with clamps 1659 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1660 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1661 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1662 Supply & Erection of 35 Sqmm PG Clamps as per TS 1663 Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing 1664 Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing 1665 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1666 Augmentation of LT line on 9 Mtr STP pole with AB cable (3x95+1x70+1x16) 1667 Supplyof LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1668 Erection of LT Aerial bunchedXLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1669 Supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980) 1670 Concreting of supports with Grounting f 0.270 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.5 meter with 300 mm Muffing.As per TS. 1671 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1672 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1673 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1674 Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1675 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1676 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1677 Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1678 Supply & Erection of 8 SWG GI wire for earthing as per TS 1679 Supply & Erection of Three phase SMC Distribution box with clamps 1680 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1681 Supply & Erection of Suspension clamp forLT Aerial Bunched Cable as per TS 1682 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1683 Supply & Erection of 35 Sqmm PG Clamps as per TS 1684 Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing 1685 Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing 1686 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1687 Supply & Erection of Feeder Bifurcation ( 33KV line on 9 mtr PCC pole(Dog conductor)) as per approved drawings, technical specifications and scope of work 1688 Supply of 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1689 Erection of6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1690 Supply & Erection 9m/400 kgs PCC Poles (PCC pole as per state practice) 1691 Supply & Erection of Stone Pad 300x300x75 MM 1692 Concreting of poles as per specification 1693 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1694 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1695 Supply & Erection of Barbed wire 1696 Supply & Erection of Danger Board 1697 Supply &Erection of Number Plate 1698 Supply& Erection of Stay Set ( Galvanised) GI stay rod 20x1800 mm, stay wire 7/8 SWG GI wire, 50x8 mm stay clamp, stay insulator (2 nos.), anchor plate (300x300x8), nut bolts, 2 nos. turn buckles, 1.8 m long 20 mm dia. Solid GI Stay Rod, 7/4.0mm dia. GI stranded wire 1699 Groutingof complete stay set with0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1700 Supply & Erection 33 KV polymer Disc insulator 70 KNB&S along with suitable hardware fittings 1701 Supplt & Erection of 33 KV polymer Pin insulators with GI Pin & nuts 1702 Supply & Erection of GI earthing Spike earthing 20x2500 mm solid rod & 6 SWG earthwire with nut and bolt 1703 Supply & Erection of 6 SWGGI wire, 1704 Supply & Eection of 8 SWG GI wire 1705 Supply & Erection of Feeder Bifurcation (33KV line on 11 mtr steel tubularpole(Dog conductor)) as per approved drawings, technical specifications and scope of work 1706 Supplyof6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1707 Erectionof 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1708 Supply & Erection of 11 m long steel tubular poles with welded steel base plate of designation 410 SP 55 (As per IS: 2713 , pt. I,II,III 1980) 1709 Concreting of poles as per specification 1710 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1711 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1712 Supply & Erection of Danger Board 1713 Supply & Erection ofbarbed wire 1714 Supply & Erection of Number Plate 1715 Supply & Erection of Stay Set ( Galvanised) GI stay rod 20x1800 mm, stay wire 7/8 SWG GI wire, 50x8 mm stay clamp, stay insulator (2 nos.), anchor plate (300x300x8), nut bolts, 2 nos. turn buckles, 1.8 m long 20 mm dia. Solid GI Stay Rod, 7/4.0mm dia. GI stranded wire 1716 Erection of complete stay set with0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1717 Supply & Erection of 33 KV polymer Disc insulator 70 KNB&S along with suitable hardware fittings 1718 Supply & Erection of 33 KV polymer Pin insulators with GI Pin & nuts 1719 Supply & Erection of GI earthing Spike earthing 20x2500 mm solid rod & 6 SWG earthwire with nut and bolt 1720 Supply & Erection of 6 SWG Wire 1721 Supply & Erection of 8 SWG GI wire, 1722 Supply & Paintingof silver paint 1723 Supply & painting of red oxidepaint 1724 Supply & Erection of Feeder Bifurcation (33KV Line on 13 mtr steel tubularpole Dog conductor) as per approved drawings, technical specifications and scope of work 1725 Supplyof 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1726 Erection of 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog 1727 Supply & Erection of 13 m longSTP SP72 1728 Supply & Erection of Stone Pad 300x300x75 MM 1729 Concreting of poles as per specification 1730 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1731 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1732 Supply & Erection of Danger Board 1733 Supply & Erection of Barbed wire 1734 Supply & Erection of Number Plate 1735 Supply & Erection of Stay Set ( Galvanised) GI stay rod 20x1800 mm, stay wire 7/8 SWG GI wire, 50x8 mm stay clamp, stay insulator (2 nos.), anchor plate (300x300x8), nut bolts, 2 nos. turn buckles, 1.8 m long 20 mm dia. Solid GI Stay Rod, 7/4.0mm dia. GI stranded wire 1736 Groutingof stay set with0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1737 Supply & Erection of 33 KV polymer Disc insulator 70 KNB&S along with suitable hardware fittings 1738 Supply & Erection of 33 KV polymer Pin insulators with GI Pin & nuts 1739 Supply & Erection of GI earthing Spike earthing 20x2500 mm solid rod & 6 SWG earthwire with nut and bolt 1740 Supply & Erection of 6 SWG GI wire, 1741 Supply & Erection of8 SWG GI wire, 1742 Supply & Painting of silver paint 1743 Supply & Painting of red oxidepaint 1744 Supply & Erection of 33 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 1745 Supply & Erection, testing & commissioning of33 kV LINEFORUNDER GROUND RAILWAY CROSSING (300 Mtr) BY 2 Nos (INCLUDING ONE SPARE)3Cx300 Sqmm XLPE Armoured Cable USING 150MM DIA GI PIPES (grade A for underground laying and grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS,LUGS, 4 Nos GI 3-Meters LONG pipe, EARTHING, 8 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS, JUMPERING , AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 1746 Supply & Erection for Feeder Bifurcation of 3 phase 11 kV line on 8.5 mtr PCC pole (Weasel conductor) using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 1747 Supply of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel conductor 1748 Erection of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel conductor 1749 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1750 Grouting of 8.5 PCC poleusing 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications: (state practices of PCC pole and base plate/stone to be used) 1751 Supply & Erection ofStone Pad(300x300x75mm) 1752 Supply & Erection for New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1753 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1754 Supply & Erection of 11 KV danger board 1755 Supply & Erection of GI Barbed wire 12 SWG 1756 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1757 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1758 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1759 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1760 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1761 Supply & Erection of 6 SWG GI wire 1762 Supply & Erection of 8 SWG GI wire 1763 Supply & Erection of PG Clamp for Weasel to Weasel conductor 1764 Supply & Erection of Aluminium Jointing sleave for ACSR Weasel 1765 Supply & Erection for Feeder Bifurcation of 3 phase 11 kV line on 8.5 mtr PCC pole (Rabbit conductor)using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 1766 Supply of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbitconductor 1767 Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbitconductor 1768 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1769 Grouting of 8.5 PCC poleusing 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications: (state practices of PCC pole and base plate/stone to be used) 1770 Supply & Erection ofStone Pad(300x300x75mm) 1771 Supply & Erection for New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1772 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1773 Supply & Erection of 11 KV danger board 1774 Supply & Erection of GI Barbed wire 12 SWG 1775 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1776 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1777 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1778 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1779 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1780 Supply & Erection of 6 SWG GI wire 1781 Supply & Erection of 8 SWG GI wire 1782 Supply & Erection of PG Clamp for Rabbit to Rabbit conductor 1783 Supply & Erection of Aluminium Jointing sleave for ACSR Rabbit 1784 Supply & Erection for Feeder Bifurcation of 3 phase 11 kV line on 8.5 mtr PCC pole (Dog conductor) using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 1785 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor 1786 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor 1787 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1788 Grouting of 8.5 PCC poleusing 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications: (state practices of PCC pole and base plate/stone to be used) 1789 Supply & Erection ofStone Pad(300x300x75mm) 1790 Supply & Erection for new 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1791 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1792 Supply & Erection of 11 KV danger board 1793 Supply & Erection of GI Barbed wire 12 SWG 1794 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1795 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1796 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1797 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1798 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1799 Supply & Erection of 6 SWG GI wire 1800 Supply & Erection of 8 SWG GI wire 1801 Supply & Erection of PG Clamp for Dog to Dog conductor 1802 Supply & Erection of Aluminium Jointing sleave for ACSR DOG 1803 Supply & Erection for Feeder Bifurcation of 3 phase 11 kV lineon 11 mtr STP(Dog conductor) using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 1804 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor 1805 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor 1806 Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1807 Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1808 Supply & Erectio ofStone Pad(300x300x75mm) 1809 Supply & Erection for new 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1810 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1811 Supply & Erection of 11 KV danger board 1812 Supply & Erection of GI Barbed wire 12 SWG 1813 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1814 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1815 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1816 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1817 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1818 Supply & Erection of 6 SWG GI wire 1819 Supply & Erection of 8 SWG GI wire 1820 Supply & Erection of PG Clamp for Dog to Dog conductor 1821 Supply& Erection of Aluminium Jointing sleave for ACSR DOG 1822 Supply & Erection of 11 KV Lineunderground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work 1823 Supply & Erection for 11 KV lineunder ground Railway crossing with 2 nos (Including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) using 150mm dia GI pipes (grade A for underground laying and grade B for pole support), Outdoor heat shrinkable cable jointing kit, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES,CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK. 1824 Supply & Erection of 12 KV 3ph Indoor type switch gear and 11 KV XLPE cable as per technical specifications, approved drawings and scope of works: 1825 Supply & Erection of Indoor type 12 KV 3 Ph 1250 A VCB with control and protection system for out going feeder consisting ofCT, A-meter, volt-meter, Relays, energy meter (TVM) DLMS compliant & accessories complete as per specifications for feeder breaker 1826 Supply & Laying of Cable AL 3X185 sqmm XLPE 11 KV 1827 Supply & Erection of 11 KV cable jointing kit indoor 185 sq.mm. 1828 Supply & Erection of 11 KV cable jointing kit outdoor 185 sq.mm. 1829 Control Cable 1830 Supply & Laying of 4x2.5 mm sq 1831 Supply & Laying of 2x2.5mm sq 1832 Supply & Erection of 11KVAgriculture Feeder Splitting LT line on 8.5 mtr PCC pole with AB cable (3x50+1x35+1x16) due to overloading as per approved drawings, technical specifications and scope of work 1833 Supplyof LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1834 Erection of LT Aerial bunchedXLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting) 1835 Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS 1836 Concreting of supports with Grounting of 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of8.5 MtrPCCPole of depth1.4 meter.As per TS. 1837 Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp,etc. complete asper TS & approved drawings. 1838 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS 1839 Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire requiredfor earthing) as per approved drawing. 1840 Supply & Erectionof Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1841 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1842 Supply & Erection of stay guy insulator (1 Nos.),as per TS 1843 Supply & Erectionof 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set 1844 Supply & Erection of 8 SWG GI wire for earthing as per TS 1845 Supply & Erectionof Three phase SMC Distribution box with clamps 1846 Supply & Erection of 4X35 mm^2 XLPE/PVCinsulated AL. cable for energising the distribution boxes/Kiosk 1847 Supply & Erectionof Suspension clamp forLT Aerial Bunched Cable as per TS 1848 Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS 1849 Supply & Erectionof 35 Sqmm PG Clamps as per TS 1850 Supply & Erection of LT Insulation piercing connector 50 -50 sqmm size for phase connection as per TS & approve drawing 1851 Supply & Erection of LT Insulation piercing connector 50-35 sqmm size for phase connection as per TS & approve drawing 1852 Supply & Erection of LT Insulation piercing connector 16-16 sqmmsize suitable for street light connection as per TS 1853 New Distribution Transformer25 KVA 11/433 KV - Supply 1854 Supply & Erectionof 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1855 Concreting of supports with Grounting f 0.44 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11mtr STP Pole of depth1.8 meter with 300 mm Muffing.As per TS. 1856 Supply & Erectionof new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel,Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete asper TS & approved drawings. 1857 Supply & Erectionof hot dip galvanized MS Nuts, Bolts with Washers as per TS 1858 Supply& Erection of 11 KV 5 KN Polymer Pin Insulators 1859 Supply& Erection of 11 KV45 KN polymer Disc insulatoras per TS. 1860 Supply& Erectionof suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductoras per TS. 1861 Supply& Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS 1862 StaySetGrouting0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS. 1863 Supply& Erection of stay guy insulator (1 Nos.),as per TS 1864 Supply& Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set 1865 Supply& Erection of 6 SWG GI wire for earthing as per TS 1866 Supply &Erectionof Barbed GI wire 12 SWG 1867 Supply& Erection of PG Clamp suitable for ACSRRabbit conductor as per TS 1868 Supply of 11 KV danger board 1869 Supply& Erection of 11 KV, 3-Pole, 3-Ph, 400A, TPMO as per TS 1870 SupplyErection of 11 KV, 3-Ph, 400A, DO Fuse as per TS 1871 Supply of 3-Phase, 11/0.4 kV, 25KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS BIS Level - 2 1872 Supply & Erection of LT Distribution box with suitable rating MCCB for incomer & MCCBfor two no outgoing feeder suitable for 25 kVA,Dist1ibution Transformer alongwith energymeter suitable for pole mounting as per TS 1873 Supply& Erectionof 9 kV, 5 KA porcelain housing Lightning Arrestorwith Disconnector for DTas per TS. (3 nos=1 set) 1874 Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm . 1875 Supply & Erection of Earthing Arrangement ofchemical pipe size of 40x3000 mm. 1876 Supply& Erection of 1-Core 70 mm2, Al. LT XLPE Cable as per TS 1877 Supply & Erection for Augmentation / Reconductoring of 33 kV line With ACSR Panther Conductor of 3 phase 33 kV line using additional supports matching with length and type of existing support asper technical specifications, scope of works and approved drawings 1878 Supplyof 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther conductor 1879 Erection of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther conductor 1880 Supply & Erection of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) 1881 Groutingof 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 1882 Supply & Erection of 9 m PCC Poles - (PCC Pole as per state practice) 1883 Erection of 9 PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 0.268 cum Cement concreting+0.014 cmt (Muffing) 1884 Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp,MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1885 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1886 Supply & Erection of 33 KV danger board 1887 Supply & Erection of GI Barbed wire 12 SWG 1888 Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings 1889 Supply & Erection of 33 KV 10 KN Polymer Pin Insulators 1890 Supply & Erection of 8 SWG GI Coil 115 turns (1.85 Kg) 1891 Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1892 Erection of complete stay set with0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1893 Supply & Erection of 6 SWG GI wire 1894 Supply & Erection of 8 SWG GI wire 1895 Supply & Erection of PG Clamp for Panther to panther conductor 1896 Supply & Painting of silver paint 1897 Supply & Painting of red oxidepaint 1898 Dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employers store . 1899 Supply & Erection ofAugmentation / Reconductoring of 11KV line With ACSR DOG Conductorof Feeder ( Older than 25 years ) as per approved drawings, technical specifications and scope of work 1900 Supplyof 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor on 11 Mtr STP 1901 Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor on 11 Mtr STP 1902 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1903 Erection of 8.5 PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 0.268 cum Cement concreting+0.014 cmt (Muffing) 1904 Supply & Erection for Augmentation of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1905 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1906 Supply & Erection of 11 KV danger board 1907 Supply & Erection ofStone Pad(300x300x75mm) 1908 Supply & Erection of GI Barbed wire 12 SWG 1909 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1910 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1911 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1912 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1913 Erection of complete stay set with0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1914 Supply & Erection of 6 SWG GI wire 1915 Supply & Erection of 8 SWG GI wire 1916 Supply & Erection of PG Clamp for Dog to Dog conductor 1917 Supply & Erection of Augmentation / Reconductoring of 11KV line With ACSR Rabbit Conductor of Feeder ( Older than 25 years ) as per approved drawings, technical specifications and scope of work 1918 Supplyof 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor- On 11 mtr STP 1919 Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor- On 11 mtr STP 1920 Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice) 1921 Erection of 8.5 PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 0.268 cum Cement concreting+0.014 cmt (Muffing) 1922 Supply & Erection for Augmentation of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work. 1923 Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work. 1924 Supply & Erection of 11 KV danger board 1925 Stone Pad(300x300x75mm) 1926 Supply & Erection of GI Barbed wire 12 SWG 1927 Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings 1928 Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings 1929 Supply & Erection of GI Earthing spike made of 20x2500mmsolid Rod 1930 Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 1931 Erection of complete stay set with0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 1932 Supply & Erection of 6 SWG GI wire 1933 Supply & Erection of 8 SWG GI wire 1934 Supply & Erection of PG Clamp for Rabbit to Rabbit conductor 1935 Supply & Erection of Automatic Capacitor Bank as per approved drawings, technical specifications and scope of work (1.98 MVAr With APFC Panel) 1936 Supply & Erection of 12.65 kV, 1980 kVAr, 3-Phase, 50 C/s, housed in Outdoor Type CRCA panel, Capacitor bank having two variable step of 792 Kvar & one Variable steps of 396 kVAr. Bank shall be complete with Capacitor units of 264/132 kVAr,Aluminium busbars, Epoxy insulators, HT HRC fuse,Surge suppressor etc.with details as follows-(1 )11 KV Alumuniumwound ,Dry type series reactor(a)0.528 KVAr for 792 KVAr step-6 nos. (b)0.264 KVAr for 396 kVAr step-3 nos. (2) 11 kV, 3-Phase Indoor Dry Type RVT-1 nos. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor-3 nos. (4) Indoor Type Automatic Control Unit-1 No. (5) IP 55, outdoor CRCA cubicle panel for accommodating capacitors, series reactors, vacuum contactor, surge supressor etc., along with FRP canopy-1 No. 1937 Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(1.98 MVAr HT Capacitor bank) 1938 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(1.98 MVAr HT Capacitor bank) 1939 Supply & Erection of Indoor Type Automatic Control Unit(1.98 MVAr HT Capacitor bank) 1940 Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(1.98 MVAr HT Capacitor bank) 1941 Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(1.98 MVAr HT Capacitor bank) 1942 Supply &Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(1.98 MVAr HT Capacitor bank) 1943 Supply &Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(1.98 MVAr HT Capacitor bank) 1944 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(1.98 MVAr HT Capacitor bank) 1945 Supply & Erectio of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(1.98 MVAr HT Capacitor bank) 1946 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(1.98 MVAr HT Capacitor bank) 1947 Casting of Civil foundation(1.98 MVAr HT Capacitor bank) 1948 Cable trench for laying of power/control cables.(1.98 MVAr HT Capacitor bank) 1949 Supply & Erection of 3.96 MVAr With APFC Panel 1950 Supply & Erection12.65 kV, 3960 kVAr, 3-Phase, 50 C/shoused in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set 1951 Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank) 1952 Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank) 1953 Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank) 1954 Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank) 1955 Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank) 1956 Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank) 1957 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank) 1958 Supply & Erection of 11KV XLPE Cable(3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank) 1959 Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank) 1960 Supply & Erection of Earthing for Panel and LAs by pipe in pipe earthing(3.96 MVAr HT Capacitor bank) 1961 Casting of Civil foundation(3.96 MVAr HT Capacitor bank) 1962 Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank) 1963 Supply & Erection of Earthing of existing substation and Distribution Transformer 1964 Supply & Erection of Pipe rod earthing with 3000mm long, 40 mm diameterGI pipe, GI Strip of 24x3mm. 1965 Supply & Erection of Spike Earthing 20mm X 2500 mm GI solidRod 1966 Supply & Erection of 8 SWG GI wire for earthing 1967 Supply ,Erection,Design & Engineeringof Renovation and Modernization of Existing Substation, Battery Charger and Battery set 1968 Supply & Erection of24V, 150 AHPb(Lead) Acid battery, battery standmade of teakwood duly painted with anti acid resistive paint, battery insulators, inter-battery wiring using 30 sqm, 1.1 kv, copper single coremulti strand cable, terminal connectors, Rubber mats & all other accessories and connectors as per technical specifications. 1969 Supply & Erection of 24V, 150 AH.Float-cum-Boost Battery Charger with full wave rectification for230V,1 phase, 50 Hz AC Input Supply & Erection as per technical specifications. 1970 36kV, 1250A,25kA for 3 seconds, 3-ph, Outdoor typeVacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. 1971 Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds,400-200/1-1 Amps ( having 3 secondery, core),type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), as required as per technical specifications complete in all respect. 1972 Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds,33 Kv/110 V single core outdoortype Potential Transformers along with junction box, as required as per technical specifications complete in all respect. 1973 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete(1 set= 3 Nos.) 1974 Supply & Erectio of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated,isolator alongwith Support Insulators, OperatingMechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch) 1975 Supply & Erection of 33 kV feeder Panel (without diffirential relays)complete 1976 Supply & Erectionof 12 KV 3 Ph 1250 A, 25kAfor 3 seconds, 3-ph, indoor typeVacuum Circuitbreaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A,3 Nos indoor type CurrentTransformer,indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as perspecifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future 1977 Supply & Erection of 11 KV 400-200/5-5 AMP moulded CT 1978 Supply & Erection of Indoor Type 11KV/110/√3 V 3-Phase PT for Indoor Type Control & Relay panel 1979 Supply & Erection of 9kV, 10kA, 1-ph Station Class LighteningArrester complete (1 Set = 3 Nos.) 1980 Suplly &Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt. 1981 Supply & Erection of 11 kv Bus-Coupler with all required accessories complete as per technical specifications, scope of works and approved drawings . 1982 Supply of 3CX300 Sqmm 33 KV XLPE Armored Cable 1983 Erection of 3CX300 Sqmm 33 KV XLPE Armored Cable 1984 Supplyof 3Cx185 Sqmm 11 KV XLPE Armored Cable 1985 Erection of 3Cx185 Sqmm 11 KV XLPE Armored Cable 1986 Civil Worksfor Control room extension, Strengthning and Miscellaneous Works required as per Scope of work, Approved drawings and Technical Specifications. 1987 Design, Engineering construction of Control room building extension 300 Sq feet for installation of Capacitor Bank pannel, including cost ofall materials, T&P and Labour,etc. as per Technical specification and approved drawing as per direction of Employer 1988 Design, Engineering construction of Control room building extension 300 Sq feet for installation of pannels for additional T/F, including cost ofall materials, T&P and Labour,etc. as per Technical specification and approved drawing as per direction of Employer 1989 Design, Engineering construction of Control room building extension 300 Sq feet for installation of pannels for Augmentation ofT/F, including cost ofall materials, T&P and Labour,etc. as per Technical specification and approved drawing as per direction of Employer 1990 Old Conrol RoomBuilding Strengthning & Miscellaneous Construction Works required as per Scope of work, Approved Drawings and Technical Specifications 1991 Construction of boundary wall (200 mtr for each substation) as per Scope of work, approved drawings and Technical specifications. 1992 Construction offire wall between two Power Transformes at Existing 33/11 KV S/S as per Scope of work, approved drawings and Technical specifications. 1993 Supply & Erection of DT Capacitor with Fitting as per Technical Specification, Approved Drawing and scope of work 1994 Supply & Erection of LT Shunt capacitor 440 Volt 10 KVAr 3Phase 50Hz IP65 1995 Supply & Erection of LT Shunt capacitor 440 Volt 25 KVAr 3Phase 50Hz IP65 1996 LT Line with 1CX25 sqmm LT armoured XLPE Cablein high loss area 1997 Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) 1998 Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31 1999 Groutingof 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 2000 Grouting of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 2001 Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work 2002 Supply & Erection of Stone Pad 300X300X75 2003 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 2004 Erection of complete stay set with0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 2005 Supply & Erection of Single core XLPE armoured cable as per technical specifications, approved drawings and scope of work. 2006 Supply & Erectio of 1.1 kV Single Core 25sqmm XLPE armoured cable (1Cx25 sqmm) 2007 Supply & Erection of LT cross arm arrangement angel (50x50x6mm) (50x8mm) (weight-9.41 kg)with Nuts and bolts 2008 Supply & Erection of LT cross arm arrangement angel (75x75x8mm) (65x8mm) (weight-18.6 kg) with Nuts and bolts 2009 Supply & Erection of C-Clamp with Nut & bolts 2010 Supply & Erection of LT shakle insulator 2011 Supply & Erection of Distribution tie for shakle insulator 2012 Mid span joint 25sqmm 2013 Single phase 20SWG CRCA MS sheet by deep drawn/sheet bending processPole top distribution box with calmps (50x6 mm) and nut & bolts and lugs suitable for 25 sqmm armoured cable 2014 Suppply of 2Cx25 SQMM Stranded Unarmoured Cable (Al Conductor ) for chargingSingle Phase DB 2015 Supply & Erection of Spike Earthing 20mm X 2500 mm GI solidRod 2016 Supply & Erection of 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers 2017 Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box 2018 Supply & Painting of silver paint 2019 Supply & Painting of red oxidepaint 2020 LT Line with 1CX120 sqmm LT XLPE Armoured Cable in high loss area 2021 Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) 2022 Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31 2023 Groutingof 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 2024 Grouting of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 2025 Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work 2026 Supply & Erection of Stone Pad 300X300X75 2027 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 2028 Groutingstay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 no.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 2029 Supply & Erection of Single core XLPE armoured cable as per technical specifications, approved drawings and scope of work. 2030 Supply & Erection of 1.1 kV Single Core 120sqmm XLPE armoured cable (1Cx120 sqmm) 2031 Supply & Erection of LT cross arm arrangement angel (50x50x6mm) (50x8mm) (weight-9.41 kg)with Nuts and bolts 2032 Supply & Erection of LT cross arm arrangement angel (75x75x8mm) (65x8mm) (weight-18.6 kg) with Nuts and bolts 2033 Supply & Erection of C-Clamp with Nut & bolts 2034 Supply LT shakle insulator 2035 Supply & Erection of Distribution tie for shakle insulator 2036 Supply & Erection of Mid span joint 120sqmm 2037 Supply & Erection of Three phase 20SWG CRCA MS sheet by deep drawn/sheet bending processPole top distribution box with calmps (50x6 mm) and nut & bolts and lugs suitable for 120 sqmm armoured cable 2038 Suppply & Erectionof 4Cx35SQMM Stranded Unarmoured Cable (Al Conductor ) for chargingThreePhase DB 2039 Supply & Erection of Spike Earthing 20mm X 2500 mm GI solidRod 2040 Supply & Erection of 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers 2041 Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box 2042 Supply & Painting of silver paint 2043 Supply & Painting of red oxidepaint 2044 LT Line with 1CX95 sqmm XLPE Armoured Cable in high loss area 2045 Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) 2046 Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31 2047 Groutingof 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 2048 Groutin of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 2049 Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work 2050 Supply & Erection of Stone Pad 300X300X75 2051 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 2052 Groutingstay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 no.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 2053 Supply & Erection of Single core XLPE armoured cable as per technical specifications, approved drawings and scope of work. 2054 Supply & Erectionof 1.1 kV Single Core 95sqmm XLPE armoured cable (1Cx95 sqmm) 2055 Suppl & Erection of LT cross arm arrangement angel (50x50x6mm) (50x8mm) (weight-9.41 kg)with Nuts and bolts 2056 Supply & Erection of LT cross arm arrangement angel (75x75x8mm) (65x8mm) (weight-18.6 kg) with Nuts and bolts 2057 Supply & Erection of C-Clamp with Nut & bolts 2058 Supply & Erection of LT shakle insulator 2059 Supply & Erection of Distribution tie for shakle insulator 2060 Supply & Erection of Mid span joint 95sqmm 2061 Supply & Eection of Three phase 20SWG CRCA MS sheet by deep drawn/sheet bending processPole top distribution box with calmps (50x6 mm) and nut & bolts and lugs suitable for 95 sqmm armoured cable 2062 Suppply of 4Cx35SQMM Stranded Unarmoured Cable (Al Conductor ) for chargingThreePhase DB 2063 Supply & Erection of Spike Earthing 20mm X 2500 mm GI solidRod 2064 Supply & Erection of 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers 2065 Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box 2066 Supply & Painting of silver paint 2067 Supply & Painting of red oxidepaint 2068 LT Line with 1CX50 sqmm XLPE Armoured Cable in high loss area 2069 Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice) 2070 Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31 2071 Groutingof 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 2072 Grouting of9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing) 2073 Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work 2074 Supply & Erection of Stone Pad 300X300X75 2075 Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI strandedwire complete as per technical specification, approved drawings and scope of work. 2076 Grouting of stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 no.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works. 2077 Supply & Erection of Single core XLPE armoured cable as per technical specifications, approved drawings and scope of work. 2078 Supply & Erection of 1.1 kV Single Core 50sqmm XLPE armoured cable (1Cx50 sqmm) 2079 Supply & Erection of LT cross arm arrangement angel (50x50x6mm) (50x8mm) (weight-9.41 kg)with Nuts and bolts 2080 Supply & Erection of LT cross arm arrangement angel (75x75x8mm) (65x8mm) (weight-18.6 kg) with Nuts and bolts 2081 Supply & erection of C-Clamp with Nut & bolts 2082 Supply & Erection of LT shakle insulator 2083 Supply & Erection of Distribution tie for shakle insulator 2084 Supply & Erection of Mid span joint 50sqmm 2085 Supply & Erection of Three phase 20SWG CRCA MS sheet by deep drawn/sheet bending processPole top distribution box with calmps (50x6 mm) and nut & bolts and lugs suitable for 50 sqmm armoured cable 2086 Suppply& Erection of 4Cx35SQMM Stranded Unarmoured Cable (Al Conductor ) for chargingThreePhase DB 2087 Supply & Erection of Spike Earthing 20mm X 2500 mm GI solidRod 2088 Supply & Erection of 8 SWG GI wire for pole,DB earthingwith GI nuts, bolts & washers 2089 Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box 2090 Supply & Painting of silver paint 2091 Supply & Painting of red oxidepaint 2092 Discount offered in % 2093 Words Final Quoted Price after Discount

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-09-2024 Corrigendum__ Other 17-09-2024
2 13-09-2024 Time Extension 4TH Date 27-09-2024
3 16-08-2024 Time Extension Date 02-09-2024
4 29-08-2024 Time Extension 3RD Date 17-09-2024

Key Value

Document Fees
INR 29500 /-
EMD
INR 50000000.0 /-
Tender Value
INR 564.83 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail