| Sl. No. | Item Description |
| 1 | BOQ Dated15 Jul 2024 |
| 2 | GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XI are prepriced by MES under Ser No. 1 to 11. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 3 | Lumpsum price worked out by the contractor for “Building or works” as listed in Schedule ‘A’Part–I |
| 4 | Lumpsum price worked out by the contractor for “Internal Water Supply (Toilet Block)as listed in Schedule ‘A’Part–II |
| 5 | Lumpsum price worked out by the contractor for “Internal Electric Supply (Toilet Block)\" as listed in Schedule ‘A’Part–III |
| 6 | Lumpsum price worked out by the contractor for “Road / Path / Culvert / Hardstanding \" as listed in Schedule ‘A’ Part IV . |
| 7 | Lumpsum price worked out by the contractor for \"Sewage Disposal\" as listed in Schedule ‘A’ Part V . |
| 8 | Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part – VI. |
| 9 | Lumpsum price worked out by the contractor for “Jaffery Wall” as listed in Schedule ‘A’ Part – VII. |
| 10 | Lumpsum price worked out by the contractor for “Addn/Altn (B/R Works)” as listed in Schedule ‘A’ Part – VIII. |
| 11 | Lumpsum price worked out by the contractor for “Addn/Altn (E/M Works)” as listed in Schedule ‘A’ Part – IX. |
| 12 | Lumpsum price worked out by the contractor for “Hot Water Supply” as listed in Schedule ‘A’ Part – X. |
| 13 | Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – XI. |
| 14 | Schedule ‘A’ Parts XII is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. |
| 15 | Schedule \"A\" Part - XII : Fittings, Fixtures & Misc items: INTERNAL WATER SUPPLY (Toilet Block)Supply and fix 15mm bore angle cock cast copper alloy fancy type chromium plated for PP-R pipe complete all as specified and as directed. |
| 16 | INTERNAL ELECTRIC SUPPLYSupply and fix LED lights fitting 1x 20W, 220V, Total 2000 Lumens, luminous efficacy 100 lumen/watt, AC decorative box type with driver, holder including LED tube light connectingwith three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 17 | Supply and fix LED lights fitting 1x 10W, 220V, Lumen efficacy 110 Lumen / watt, Total Lumen 1100, 6500 K, Cool day light, AC decorative box type with driver,holder including LED tube light connectingwith three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 18 | ADDN/ALTN (B/R Works)Material and labour for providing and fixing 8-10mm thick Gypsum board in ceiling over powder coated aluminium snap grid frame work supported by hanger not less than 4 mm dia GI (up to length as per site requirement) adjusting level fixed to roof slab/walls/wooden/steel members by means of ceiling cleats made out of GI flat 40x3mm size 60 cm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified for false ceiling fixed with screws as per manufacturer\"s instruction all as specified and as directed. |
| 19 | Cleaning and preparation of the surface to receive Fosroc Proofex ORGor its equivalent in approved make water proofing system shall be a sound base, any crack shall be treated with cementious repair mortar of Fosroc Renderoc CS or epoxy crack filling mortar by proper grooving arrangement all as directed. |
| 20 | Providing and laying / fixing TPO membrane of non-flammable waterproofing of roof which shall be a 1.5mm thick loose laid TPO membrane layers overlapped to achieve a minimum weld of 110mm, Hot air welding can be either hand applied or by means of automatic machines and the rolls either end are overlapped with layers of non-woven geotextile fiber, the separation layer provided to prevent the mechanical abrasion and cushioning between the Fosroc Proofex ORG membrane or its equivalent in approved make and the concrete substructure, the termination of Fosroc Proofex ORG or its equivalent in approved make by aluminium strip anchoring.Note: Work shall be executed by authorised applicator with prior experience of more than 5 years in applying similar system. |
| 21 | ADDN/ALTN (E/M Works)Supply and Fix in lieu of old UNSV FTL/CFL fitting with REGAL Batten for LED tube with single LED Lamp 1x 20 W, Ultra bright glass LED Tube light (Double side connection) with very high efficacy with lamp holders etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 22 | Supply and fix in lieu of old UNSV FTL/CFL fitting9/10 watt LED LUMILINE surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver. |
| 23 | Supply and fix in lieu of old UNSV DB with Vertical TPN MCCB DB incomer 4 way 12 outgoing having IP-43 protection, Powder coated sheet steel enclosure fitted with bus bar, DIN channel & neutral link & earth link.Make : Havells Cat No DHDLVDRWGOFO04 or equivalent in L & T/Schneider/Legrand.Note :MCCB will be measured and paid separately. |
| 24 | Supply and fix in lieu of old UNSV MCCB with four pole MCCB 100 Amp, 50 Hz 415 V with rupturing capacity 25 KA with fixed thermal magnetic release type complete all as specified and as directed. |
| 25 | Supply and fix LED building security light made of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP-66 protection with SPDLED street lightof 25 Watt all as Crompton Cat Part No - LSTS-25-CDL-M of Cromptonmake or equivalent make ofBajaj/Philips/Wipro/Havells with suitable sizebracket made to shape of 40 mm dia GI pipe medium grade of 1.2 mtr length including MS clamps 25 x 4 mm - 02 Nos with nut bolts washers complete all as specified and as directed. |
| 26 | Supply and Fix LED Light fitting 36 Watts of size 2 x 2 LED edge-lite luminaries suitable for Armstrong/grid ceiling complete for low ceiling application with LED Drive of 36 Watts complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Model No : Havells Cat No PLUTONEO2X2PLR28WLED840S or its equivalent in approved make. |
| 27 | Material and labour for Earthingcomplete with galvanised mild steel earth plate electrode of size600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron strip 32 x 6 mm as earthing lead by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinforcement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 40mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion.NOTE: (i) The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber. (Internal Electric Supply - 24Nos, Hot Water Supply - 10Nos & External Electrification - 24 Nos) |
| 28 | Material and labour for Earthingcomplete with galvanised mild steel earth plate electrode of size600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron orearth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinforcement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion.NOTE: (i) The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber. (Internal Electric Supply - 4Nos & External Electrification - 4 Nos) |
| 29 | Supply and fix in lieu of old UNSV FTL/CFL with square surface mounted LED 18 W panel, PDC aluminium housing and high translucent frosted plastic diffuser makes it a robust Luminaire, Efficacy 100lm/w complete. Make : CROMPTON Cart Part No-LCDSPLN-S-18-WW or its equivalent in approved make. |
| 30 | HOT WATER SUPPLYMaterial and labour for Cutting of existing pipe 150 mm dia GI medium grade rising pipe for tapping of proposed inlet pipe of solar water heater including necessary fittings and accessories of connection complete all as specified and as directed. |
| 31 | Supply and fix DWC Pipe IS-16205, size inner dia 103 mm, outer dia 120 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed by Engr-in-Charge. |
| 32 | Supply and fix DWC Pipe IS-16205, size inner dia 63 mm, outer dia 75 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed by Engr-in-Charge. |
| 33 | Material and labour for LT Cable route indicator with a welded/riveted disc of 4 inch dia and engraved with cable with cable route marker made out of angle iron 40 x 40 x4 mm thick dug in ground with in and including PCC 1:3:6 type C1 using 20mm graded aggregate at approx distance 100 mtr including necessary earth work complete all as specified and directed by Engr-in-Charge. |
| 34 | Material and labour for construction of valve pit chamber of size 600 mm x 600 mm x 600 mm (internal size) with 3.15 mm thick MS sheet cover and angle iron 50 x 50 x 6 mm thick fame embedded in 15 cm thick PCC coping with locking arrangement with two coats of synthetic enamel with internal external surfaces over a coat of red oxide primer including necessary excavation removal of surplus soil to a distance not exceeding 50 mtr returning filling in PCC 1:3:6 type C2 75 mm thick as in foundation/floor brick work (one brick thick) in cement mortars (1:4) PCC 1:2:4 type C1 in copping, Plastering in cement mortar 1:4 and 75 mm thick hard core below foundation etc complete all as specified and as directed. |
| 35 | Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size for accommodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 52, suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 40 x 40 x 40 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, with sloping canopy at top, double hinged doors at front with suitable locking arrangement and Bus Bar Minimum range 200 Amps supported on non hygroscopic fibres and brass screws for mounting - 04 Nosfixed with Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated complete. (ForEach billets)INCOMER(a) Supply and fixing MCB TPN 40 Amps, 415 Volts of breaking capacity of 10 KA - 01 NoOUTGOING FEEDERS(a) Supply and fixing MCB SPN 40 Amps, 230Volts of breaking capacity of 10 KA- 05 Nos |
| 36 | Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size for accommodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 52, suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 40 x 40 x 40 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, and MCCBs, with sloping canopy at top, double hinged doors at front with suitable locking arrangement and Bus Bar Minimum range 400 Amps supported on non hygroscopic fibres and brass screws for mounting - 04 Nosfixed with Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated complete (ForMain Incoming Panel). INCOMER(a) Supply and fix MCCB 4 pole 415 Volts of breaking capacity of 16 KA of 63 Amps- 01 NoOUTGOING FEEDERS(a) Supply and fix MCBTPN 40 Amps, 415 Volts of breaking capacity of 10 KA - 04 Nos |
| 37 | Cutting the tar macadam road / hard standings for laying cable and excavating not exceeding 1.5 wide and 1.5m indepth and getting out all as directed including filing back and finishing it with PCC complete matching with the surroundings. |
| 38 | EXTERNAL ELECTRIFICATIONSupply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 250A (50 x 6 mm) electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete:-(a) MCCB FP 160 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA - 01 No (Incoming)(b) MCCB FP 80 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA - 02 Nos(outgoing) (c) Voltmeter 0-500V digital type with selector switch- 1 No(d) Indicator lamp LED type - 3 Nos (R, Y & B)(e) Digital type meters ampere meter with suitable selector switch including suitable resin cast CTs of 250/5 A - 01 NoNote:- Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires |
| 39 | Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 600A electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete:-(a) MCCB FP 400 Amps rating, 50 Hz, 415 V with rupturing capacity 50 KA - 01 No (Incoming)(b) MCCB FP 100 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA - 01 No(outgoing) (c) MCCB FP 63 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA - 04 Nos(outgoing) (d) Voltmeter 0-500 V digital type with selector switch- 1No(e) Indicator lamp LED type - 3 Nos (R, Y & B)(f) Digital type meters ampere meter with suitable selector switch including suitable resin cast CTs of 600/5 A - 01 NoNote:- Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires |
| 40 | Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 200A electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete:-(a) MCCB FP 100 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA - 01 No (Incoming)(b) MCCB FP 63 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA - 01 No (outgoing) (c) MCB TPN 20 Amps rating, 50 Hz, 415 V, C Curve with rupturing capacity 10 KA - 01 No (outgoing)(d) MCB TPN 16 Amps rating, 50 Hz, 415 V, C Curve with rupturing capacity 10 KA - 03 Nos (outgoing)(e) MCB SPN 32 Amps rating, 50 Hz, 240 V, C Curve with rupturing capacity 10 KA - 06 Nos (outgoing)(f) Voltmeter 0-500 V digital type with selector switch - 1 No(g) Indicator lamp LED type - 3 Nos (R, Y & B)(h) Digital type meters ampere meter with suitable selector switch including suitable resin cast CTs of 200/5 A - 01 NoNote:- Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires |
| 41 | Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 400A electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete:-(a) MCCB FP 250 Amps rating, 50 Hz, 415 V with rupturing capacity 35 KA - 01 No (Incoming)(b) MCCB FP 50 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA - 05 Nos(outgoing) (c) Voltmeter 0-500 V digital type with selector switch - 1 No.(d) Indicator lamp LED type - 3 Nos (R, Y & B)(e) Digital type meters ampere meter with suitable selector switch including suitable resin cast CTs of 400/5 A - 01 NoNote:- Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires |
| 42 | Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 200A electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete:-(a) MCCB FP 100 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA - 01 No (Incoming)(b) MCB TPN 32 Amps rating,\"C\" Curve, 50 Hz, 415 V with rupturing capacity 10 KA - 02 Nos (outgoing) (c) MCB SP 20 Amps rating,\"C\" Curve, 50 Hz, 240 V with rupturing capacity 10 KA - 04 Nos (outgoing) (d) Voltmeter 0-500V digital type with selector switch- 1No(e) Indicator lamp LED type - 3Nos (R, Y & B)(f) Digital type meters ampere meter with suitable selector switch including suitable resin cast CTs of 200/5 A - 01 NoNote:- Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires |
| 43 | Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 400A electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete:-(a) MCCB FP 200 Amps rating, 50 Hz, 415 V with rupturing capacity 25 KA - 01 No (Incoming)(b) MCCB FP 63 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA - 03 Nos(outgoing) (c) Voltmeter 0-500 V digital type with selector switch - 1 No(d) Indicator lamp LED type - 3 Nos (R, Y & B)(e) Digital type meters ampere meter with suitable selector switch including suitable resin cast CTs of 400/5 A - 01 NoNote:- Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires |
| 44 | Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 100A electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete:-(a) MCCB FP 25 Amps rating, 50 Hz, 415 V with rupturing capacity 10 KA - 01 No (Incoming)(b) MCB SP 16 Amps rating, 50 Hz, 240 V with rupturing capacity 10 KA - 10 Nos(outgoing) (c) Voltmeter 0-500 V digital type with selector switch - 1 No(d) Indicator lamp LED type - 3 Nos (R, Y & B)(e) Digital type meters ampere meter with suitable selector switch including suitable resin cast CTs of 100/5 A - 01 NoNote:- Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires |
| 45 | Supply and fix IP-65 new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaries for diffused lighting with high power LED 8 wattincluding necessary excavation andPCC foundation for erectingBollard as per manufacture recommendation all as per Havells Cat Part No BAMBOOBLS8WLED857PSYMTOPC ofMake Havellsor its equivalent in make of Bajaj/Surya/Philips/C&Sincluding taking down old US fitting complete all as specified and as directed. |
| 46 | Cutting the tar macadam road / hard standings for laying cable and excavating not exceeding 1.5 wide and 1.5m indepth and getting out all as directed including filing back and finishing it with PCC 1:2:4 using 20mm graded stone aggragate complete matching with the surroundings complete all as specified and as directed. |
| 47 | Supply and fix LEDFlood light fittings 100 WattEnergy saving, environmental friendly, long life, exclusive innovative die-cast aluminium non integral IP66, including SPD 10 KV suitable for high mast application, highlighting architectural facade and general purpose lighting complete all as directed including taking down old UNSV flood light fitting.Make: Crompton Cat Part No CFS-504-100-30-60D-SL-GL-NSG or its equivalent in make of Bajaj/Wipro/Havells with all accessories & fitting arrangement. |
| 48 | Supply and fix street light fitting LED 45 watt made up of pressure die cast housing with toughened glass and high power LEDs with secondary optics with IP-66 protection including necessary fixing arrangement i.e. GI clamps, nuts bolts and washers etc all as specified and directed including taking down Old US fitting. Make: CROMPTON Cart Part No-LSTS-45-CDL-M or its equivalent in approved make. |
| 49 | Material and labour for wiring Multi core round cable PVC insulated and FR PVC round sheathed, copper conductor (flexible) industrial cable, 1100 volt, conforming to IS 694, 1.5 Sqmm three core drawn through PVC conduit of suitable size but not less than 25mm dia for electric connection from loop in loop out box to street light fittings complete all as specified and as directed. |
| 50 | Supply and fix FRP Cable loop in loop out box 250mm x 200mm x 105mm (Inside Dia) with 3 Phase 4 wires connector and 1 No of MCB, SP 6-32 Amps including necessary fixing arrangements with clamps fabricated out of Flat Iron of 20x3 mm including nuts, bolts and washers on poles complete all as specified and as directed. |
| 51 | Supply and fix distribution board of 16 A 3 pole/230 V Analog time switchcomplete all as specified and as directed. Make : Cat Part No TL016AB0of Indoasian or its equivalent in approved make. |
| 52 | Supply and fixPVC conduit of 25mm dia for electric connection from loop in loop out box to street light fittings complete all as specified and as directed. |