}

Tender For The Work Against Deposit Package No. D-452/2023-24 In Jurisdiction Of Edd-Ist, Bijnor, In Relation To Package Number D-452/2023-24 Approved In The Deposit Scheme Under Electricity Distribution Block-I, Bijnor, The Work Of Strengthening The Alre, bijnor-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Tender For The Work Against Deposit Package No. D-452/2023-24 In Jurisdiction Of Edd-Ist, Bijnor, In Relation To Package Number D-452/2023-24 Approved In The Deposit Scheme Under Electricity Distribution Block-I, Bijnor, The Work Of Strengthening The Alre. Submission Date for this Tender is 18-07-2024. Civil Work Tenders in bijnor Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

44169940
Tender For The Work Against Deposit Package No. D-452/2023-24 In Jurisdiction Of Edd-Ist, Bijnor, In Relation To Package Number D-452/2023-24 Approved In The Deposit Scheme Under Electricity Distribution Block-I, Bijnor, The Work Of Strengthening The Alre
Open Tender
Indian
Uttar Pradesh
Bijnor
18-07-2024

Tender Details

Tender For The Work Against Deposit Package No. D-452/2023-24 In Jurisdiction Of Edd-Ist, Bijnor, In relation to package number D-452/2023-24 approved in the deposit scheme under Electricity Distribution Block-I, Bijnor, the work of strengthening the already established 33 kV line from 132 kV substation Bijnor to Mahatma Vidur Autonomous State Medical College Bijnor and construction of new 33 kV line and construction of 2×5 MVA capacity electrical substation and issuing connection under 2000 kVA HV-1 mode through 11 kV independent feeder., 1 SAFE CARRIAGE OF FOLLOWING MATERIAL WITH LOADING & UNLOADING AT BOTH ENDS (PVVNL STORETO SITE) RESPECTIVELY as per Respo Norms. 2 33 KV Bus Isolator 800 Amp/Line Isolator 3 33 KV Fuse Set 4 11 KV TPMO 5 33 KV Pin Insulator With Pin 6 33 KV Disc Insulator With Fitting 7 33 KV V-Type Cross Arm 8 34 KV Stay Complete 9 33 KV Lightening Arrestor 10 33 KV Post Insulator 11 24 Volt Battery & Battery charger Set 12 Cable Jointing Kit 3x300sqmm and 3x120 sqmm 13 11 KV Incoming Switch Gear 600/300/5A 350MVA 14 11 KV Outgoing Switch Gear 200/100/5A 350MVA 15 11 KV Bus Coupler VCB, 350 MVA 16 33KV MOCB/VCB 800A750MVA 17 33KV MOCB/VCB 1250A750MVA 18 33kV Control Panel for Double T/F without Differential Relay 19 33kV Control Panel for Single Feeder 20 33KV CT 200/100/1-1A 21 33 kV 1 Ph CT 400/200/1 Amp. 22 33kV 1 Ph PT 33kV/110 V 23 11 Mtr long STP(SP-55) (Bottom portion Galvanised) 24 13 Mtr. STP(SP-72) (Bottom portion Galvanised) 25 11/0.44 KV 63 KVA Transformer (Four Star Rating, Level-II) 26 11KV 3x300 mm2XLPE Cable / 11KV 3x185mm2 XLPE Cable / 11KV 3x50mm2 XLPE Cable 27 33/11 KV 05MVA Power Transformer 28 11 KV Meter Cubical 29 11 KV Outdoor CT/PT 30 ACSR Dog Conductor (13.63x3+3%+300) 31 Safe Shifting of 05MVA, 33/11 KV, Power transformer from out side of switchyard to near Power transformer plinth in Switchyard. 32 Erection&Installationof05MVAPowertransformeronPowerTransformerplinthbyfixingallaccessorieslikeradiators,conservatortank,fillingthetransformeroilto desired level and ensuring that there is no leakage after providing new radiator seals etc by the contractor in case of 5MVA T/F complete job in all respect. Reconnecting 2 Nos. earthing strip to transformer body. 33 Erection & Installation of 11/0.4KV substation transformer 34 Earthing of Outdoor Equipments in Switchyard, as per site requirement/as per PVVNL guideline details as given below:-Digging of Trench of size-0.50x0.75x30M.,for laying of Earthmat throughout in required full portion of switchyard and refilling & ramming of the same earth into the trenches after completion of Earthmat work, Laying of 32mm.dia M.S.Bar in Trench, properly in alignment along the length and width in switchyard, Cutting of 32mm.dia M.S.Bar- 3M.long and making one end in conical shape,by forging process and driving it into the earth, in trench at fixed distance as per drawing and properly welding with M.S.Bar Earthmat, Proper continuous electric welding of overlap joints of M.S.Bar upto a length of 150mm. On both sides,along the length of M.S.Bar and an extra piece of 12mm M.S.Round-150mm.long, providing on both sides of Overlap Joints and continuous electric welding on both side, along the length of M.S.Bar. All joints shall be painted with black bituminous paint,Proper electric welding at X-joints of M.S.Bar and welding by providing 25x6mm.”U” type Clamp of M.S.Flat, and proper continuous electric welding with M.S.Electrode and M.S.Bar at each X-joints. All joints shall be painted with black bituminous paint and as per site requirement. 35 Providing &laying of G.I.Strip of size 50x6mm for connecting the earthmat with each equipment (Bus Isolators, 33KV C.T., 33KV V.C.B., L.As., Fuse Set, Post Insulators, T/F Body & its neutral and M.S.Frame of Cabe Supporting Structure), various steel structures. The work also includes cutting, bending, straightening, over laping and welding the earth strip with earth mat and by using high quality arc welding in already digged trenches, as per PVVNL guidline and as per site requirement. 36 Fixing M.S Round 32mm dia and Making delta earthing for power T/F neutral/L.A as per RESPO Norms. 37 Making earthing of all 11KV Switchgears, P.T. and other outdoor equipments on both earth terminal inside the control room by G.I.Strip in size 50x6mm. with 32mm. dia M.S.Round laid in trench with proper electric welding, as per PVVNL guidline. 38 Water level earthing With G.I pipe ID-40mm & OD-46mm, 3mm Thick with 6SWG Copper wire as per specification upto 80 Feet with copper cone 750gm. 39 Water level earthing With G.I pipe ID-40mm & OD-46mm, 3mm Thick with 6SWG Copper wire as per specification upto 120 Feet with copper cone 750gm. 40 Water level earthing With G.I pipe ID-40mm & OD-46mm, 3mm Thick with 6SWG Copper wire as per specification upto 150 Feet with copper cone 750gm. 41 Construction of Plinth for 5MVA/10MVA, 33/11KV T/F, in size-3.46x4.46 Mtrs., as per drawing, as per PVVNL guidline and site requirements, details as given below:-Excavation of earth in foundation. Cement concrete in foundation in ratio 1:6:12, Cement, Sand & Brick ballast., First Class Brick work in ratio 1:4 with Cement & Coarse sand mortar., Cement concreting inner side of plinth in ratio 1:4:8, Cement, Coarse sand and stone shingle. M.S.work for re-inforcement 12mm. Tor at a distance of 15Cms. apart, including cutting, bending & binding by wire to each other for making JAL in two layer, 12 to 15Cms. apart. 42 Fixing of 3.5Mtr.long, 2No. Rail Pices, 90Lbs, on top of Plinth at proper distance in alignment by C.C. 43 Cement concrete in ratio 1:2:4, Cement, Coarse sand & Stone shingle, on top of the plinth, including fixing of M.S.Tor Jal. 12mm.thick Cement Plaster in ratio 1:4, Cement & Sand mortar, on all side of plinth, Neat cement coating 3mm.thick on top surface of plinth. 44 Plinth of Substation T/F with RCC Top of size 2x2x1.6 Mtr. Incl. 2 nos. MS Channel of 100x50mm 45 Installation of 33KV Bus Isolator/Line Isolator with structure, Fabrication, excavation, erection, grouting (with cement, coarse sand and stone shingle) and making of plinth of BUS ISOLATOR STRUCTURE as per RESPO Drawing, as per PVVNL guidline and site requirements. Fabrication of Structure, including cutting, straightening & drilling of holes in Channel/Angle including supply of materials. 46 Excavation of earth, Grouting of structure in C.C. ratio 1:4:8, Erection of Line/Bus Isolator structure in proper alighment., Making plinth by C.C. ratio 1:3:6 and 12mm thick plastering on plinth in ratio 1:4 47 Excavation of earth in size, making fabrication & erection of structure by making plinth C.C ratio 1:3:6, 12mm thick plasting on plinth in ratio 1:4 : Post insulator structure 48 P.T structure as per RESPO Norms. 49 33KV C.T Strucure as per RESPO Norms. 50 33KV Fuse set structure as per RESPO Norms. 51 33KV L.A Structure as per RESPO Norms. 52 Installation & mounting of following materials on erected structure (The Work also includes safe removal of old items present in acquired land) as per respo norms. 53 Mounting of 33KV Post Insulator 54 33KV PT 55 33KV C.T (200/100/1A, 400/100/1A) 56 Mounting of 33KV Fuse Set 57 Mounting of 33KV L.A 58 33KV Bus Isolator / Line Isolator 59 Providing and Fixing of 33KV CT Junction Box 60 Providing and Fixing of C.T Connector for providing Input & Output coneection 61 Construction of plinth for the structure of 33 KV VCB as per detail and as per respo norms. Excavation of earth of size (2.4×1.5×1.0) m pits for construction of plinth. (3.6 Cum), Brick Ballast ratio (1:4:8) (cement, sand & brick ballast ) for foundation work (2.4×1.5×0.15)m plinth. (0.54 Cum), C.C. work in ratio 1:2:4 (cement, coarse sand &stone grit) of 20mm size for making plinth of size (2.4×1.5×1.00)m and grouting of foundation bolts 04 Nos. for 33 KV VCB. 3.6 Cum) & 12 mm thick plaster with cement mortar in ratio 1:4 (cement & fine sand) of plinth of 0.15 m above ground level size (2.4×1.5)m. (4.77 Cum) 62 Assembling and installation of 33 KV VCB on the VCB out door structure on the plinth.Adjustment of operating mechanism in proper alignment for smooth operation of thesame. The work also includes fabrication of addition arrangement for proper fixing, if required and also safe removal of old 33KV VCB if applicable. 63 Laying,Stringing&SaggingofACSRDogConductorfrommainBusBartoPowerT/F,throughPostInsulator,BusIsolator,C.Ts,VCBandL.As.,by providing&fixing P.G.Clamp/Connectors, suitable for Dog/Panther. 64 Erection of I/C Switchgear, Bus Coupler, O/G Switchgears & Double T/F Control panel in alignment, in Control Room, including safe shifting, from Dump Place. The work also includes safe removal of old switch gears to safe place if applicable. Making 4No. Pockets for each and providing/fixing of Reg Bolt by CC in ratio 1:2:4, with tightening also. As per PVVNL guidline. 65 Commissioning & fixing of Bus bar (Copper), between each Switchgear, Double T/F Control panel control cable, by bolt, nut & washers and HT compound and providing & tapping HT Tape, Empire Tape & PVC Tape, on each joint & Bus Coupler connect which existing Bus-bar. ( If extra fitting/adjustment or suitable copper bus-Bar for fitment required then provided by the contractor) 66 Preparation of 33 KV Power Cable ends: as per RESPO specification of the following : 67 Making of cableendterminationbyHeat shrinkableOut door jointing kits suitablefor 33KV, 3x300q.mm XLPE cable.Providing, fixingandcrimpingofpropersizegood quality lugs complete in all respect. 68 Providing and Errection 2x2.5 mm2 Control Cable 69 Providing and Errection 4x2.5 mm2 Control Cable 70 Preparation of 11 KV Power Cable ends, specification of the following as per RESPO Norms. 71 Making of cableendterminationbyHeat shrinkableOut door jointing kits suitablefor 11KV, 3x300q.mm XLPE cable.Providing, fixingandcrimpingofpropersizegood quality lugs complete in all respect. 72 Making ofcable end termination by Heat shrinkable indoor jointing kits suitable for 11KV, 3x300Sq.mm XLPE cable.Providing, fixing and crimping of proper size good quality lugs complete in all respect. 73 Making of cableendterminationbyHeat shrinkableOut door jointing kits suitablefor 11KV, 3x185q.mm XLPE cable.Providing, fixingandcrimpingofpropersizegood quality lugs complete in all respect. 74 Making ofcable end termination by Heat shrinkable indoor jointing kits suitable for 11KV, 3x185Sq.mm XLPE cable.Providing, fixing and crimping of proper size good quality lugs complete in all respect. 75 Making, Fabrication and erection of neutral earthing L Type support made of M.S. Channel size 100×50mm. Structure shall be 4 Mtr. long with 1 Mtr. Arms. Structure shall be grouted in ratio 1:3:6 in block size 300×300×700mm and painted with one coat of Ready Mixed primer and Two coat of enamel Aluminium paint work includes connecting neutral bushing rod of power Transformer and M.S. Earthing strip with the help of flexible copper bond size 35x6mm ( by providing) M.S. Bolt and washer. 76 Cable Support as per RESPO Norms. 77 Making, Fabrication and erection of cable support made of two pieces of M.S. Channel (100x50x6)mm,joined to each other by means of M.S. channel pieces of each by welding at equal intervals and grouting in a block of size (300x1000x1000)mm in C.C. 1:3:6 complete with one coat of ready mixed primer and two coats of Al. paint. Work includes providing of three Nos. M.S. clamps made of (50x6)mm M.S. Flat for holding the cable including nuts and bolts with stone Pad of size (300x300x75mm). 78 Providing & Fixing 110mm dia 2mm thick 2M long G.I.Pipe over 11KV, 3x300Sq.mm XLPE Cable before mounting the 2No. Cable on cable support structure. Work includes fixing of Clamp, sealing of top and bottom end of the G.I.Pipe. One end of G.I.Pipe is to be buried under earth about 500mm. 79 Copper bus bar support T-type M.S.Structure(As per site requirement) and as per RESPO Norms. 80 MakingFabrication and grouting erection of M.S. frames for support of copper Bus Bar in L.V. side of Power transformer. The M.S. frame shall be made of M.S. channel (100x50)mm in T shape. drilling of 3 Nos. hole on the top channel for fixing of 03No. 33 KV Post insulator. The M.S. frame shall be painted with one coat of primer & two coat of aluminium paint and grouting the frame in C.C. ratio 1:3:6 in a block of size (300x300x700) mm with stone Pad (by providing) of size (300x300x75mm). The work also includes the fixing of 33KV Post Insulator by Aluminium binding wire in complete with nut & Bolts. 81 Supply & Fabrication of copper bus bar of size (2400x50x6)mm in L.V. side for 05MVA and (3000x65x8)mm for 10MVA T/F as per requirementfor power transformer, Work includes connection of outside bus bar in L.V. side busing rod of Power Transformer and other side with outdoor 11 KV cable box as well as providing empire tape and H.T. tape etc. for proper insulation work covering copper Bus-Bar in Complete. 82 Fixing of Cable Box on 5MVA T/F, 11KV Switchgears, by Bolt & Nuts and tapping the joints by providing HT/Empire/PVC Tape. 83 LayingofControlCableinPackkaTrench,fromVCB/CTs/T/Fto33KVControlPanelandmakingconnectionforoperation&protectionofequipments,byusingferrules includingcommissioningbatterychargerwithbatterybyprovidingcopperleadwithlugsetc&dressingofControlCableandmakingarrangementfortestinginthe equipments. 84 Assembling and installation of the cabinet of 24 volt battery and battery charger including grouting of foundation bolt as per manufacturer drawing in control room including safeshifting. Theelectric connectionbetween battery and battery charger by providing flexiblecopper leadof size7/20SWG shallbe doneproperly. Thework including wireing upto control pannels, testing & commisnoning in al respect as per pvvnl guidline. 85 Providing & fixing 1 No. MCB Box 63amp. TPN and 03 No. 32 Amp. SPN box and power plug on wall and it is proper grouting including it is connection with A/C supply by providing proper size of connection wire as per pvvnl guidline. 86 CONSTRUCTION OF CONTROL CABLE TRENCH IN SWITCHYARD : (As per RESPO Norms) 87 Consstruction of control cable trench of size 30cmx30cm with trench wall thickness 23cm after exavation of earth by using 1st class bricks work in cement mortar in ratio 1:4 with c.c work foundation in ratio 1:4:8 (Cement sand & brick blast) 88 Providing & Grouting of M.S.Strip of size 25x6mm in cable trench 100mm above floor level and at equal space distance 300mm 89 Providing and Grouting of M.S.Angle Iron of size 50x50x6mm in upper edge of trench. 90 C.C.work on the Top in the ratio 1:2:4 in the grouting of Edge of the Trenches. & plastring of trench. 91 ProvidingFabricationandfixingcabletrenchcoverofprovidingM.S.AngleIronsize40x40x6mmofsize0.3mwide0.5to1.0mtrlength.Aspersiterequirement.After construction of cable trench. 92 Construction of Fire wall, as per drawing, made of cement, sand, concrete, bricks, etc., which will be arranged by the contractor. (Dimention-4.5x5Mtr or as per drawing/site requirement) 93 Construction of S.S.Os. Approach Road-1.2M wide in switch yard by laying dry brick-ballast in 15Cm layer, 115mm thick brick work 1:4 in both side of edge, providing 10Cm thick CC in ratio 1:2:4. the work includes proper plastering top & side of road and making groove, leveling & dressing of earth beneath the brick work on edge. as per site requirement & PVVNL guidline. 94 Painting of Substation structure with one coat of ready mixed primer and two coats of ISI Mark Alumn. Paint after rubbing with sand paper to the surface of the structure includidng labour and T&P complete in all respect 95 Providing required No. ofSkilled Technicians for testing & Commisning to work on power T/F, HT/LT Panels, during testing as assisting technical hands of test team during commissioning & energisation. After installation of new protection equipments (33KV VCB, C.T & Double T/F, single T/F Control panel) the contractor will ensure its testing on his own expences. 96 Fixing of Stay set complete (G.I.Stay rod 20x1800mm, Stay wire 7/8SWG 10Kg, by providing Guy insulator, G.I.Stay clamp, bolt, nut & wasther with concrete grouting) for 33KV line. 97 Fixing ofStay set complete (G.I.Stay rod 16x1800mm, Stay wire 7/10SWG 5Kg,by providing Guy insulator, G.I.Stay clamp, bolt, nut & wasther with concrete grouting) for 11KV line. 98 Providing & Fixing of P.G. Clamp for ACSRDog/Dog Conductor 99 Providing & Fixing of P.G. Clamp for ACSRRabbit/Rabbit Conductor 100 Providing & Fixing of Stone Pad (300x300x75mm) 101 Excavation, Erection Grouting and plinthing of ST Pole 13/11 MTR LONGwith(1 cement : 3 Core sand: 6 Stone Grift of 20mm size) mixture with proper quering. (0.64cu.M) as per specification 102 Providing & Fixing of Aluminium Binding Wire - 6 SWG 103 Providng of G.I. Pipe 6 dia, 3mm thick 104 Providng of G.I. Pipe 4 dia, 3mm thick 105 Providing & Fixing of G.I. Holding Clamp of 65x8mm size With Nuts, Bolts & Washers for G.I.Pipe 4, 6, 33KV & 11KV Cable/ Line 106 Providing of Eye Bolt 107 Earthing of Pole by MS Earthing Rod of 20x2500 mm. with 6 SWG earthing wire fitted by providing earthwire clamp Nut, bolts & Washers etc. as per specification. 108 Fixing of 11KV DO Fuse Set (3 Phase) 109 Fixing of V-Type Cross Arm 100x50x6 mm channel for 33KV line 110 Providing & Fixing of Cross arm holding Clamp of 75x10mm size with nuts, bolts, washers for 33KV line 111 Making & Fixing of Top Channel 125x65x6mm, 3200 mm long (13.10kg/mt) by providing clamps of 75x10mm size, bolts, nuts and washers for 33KV line double pole/ Four Pole 112 Making & Fixing of Top Channel 100x50x6x2240 mm long (9.56kg/mt) by providing Clamps of 65x8mm for 11KV line double pole 113 Making & Fixing of Angle Iron 65x65x6mm, (5.80kg/mt) 4300 mm long bracing by providing Clamps of 65x6mm,bolts, nuts and washers for 33KV line 114 Making & Fixing of Angle Iron 65x65x6 mm, (5.80kg/mt) 2700 mm long bracing complete by providing Clamps of 65x6mm, Nut, bolt and washers for 11KV line 115 Making & Fixing of Guarding angle 75x75x6 mm, (6.80kg/mt) 2200 mm long by providing Clamps 65x8mm, packing piece, nut & bolts etc. for 33KV line 116 Making & Fixing of Guarding Angle Iron 75x75x6 mm (6.80kg/mt) 3210 mm long by providing Clamps 65x8mm, packing piece, nut & bolts etc. for 33KV line double pole 117 Making & Fixing of Guarding angle 75x75x6 mm, (6.80kg/mt) 1600 mm long by providing Clamps65x8mm, packing piece, nut & bolts etc. for 11KV line 118 Providing & Fixing Holding Clamps 65x8mm size for 11KV TPMO & 11KV Fuse Set etc. with nuts, bolts & washers 119 Laying of 3x300 sq. mm. 33 KV XLPE Insulated Cable underground in HDPE Pipe or trenches HDD Method (In double layer) (For Railway Crossing /Road Crossing) for 33KV Line as per specification and Respo Norms. 120 Laying of 3x185/120 sq. mm. 11 KV XLPE Insulated Cable underground in HDPE Pipe or trenches HDD Method (In double layer) (For Railway Crossing /Road Crossing) as per specification and Respo Norms. 121 Digging of trench size 1050x750mm and Safely laying of 02No., 3x300/3x185Sq.mm. XLPE Cable in cable trench as per specification and Respo Norms. 122 Digging of trench size 1050x450mm and Safely laying of 01No., 3x300/3x185Sq.mm. XLPE Cable in cable trench as per Respo Norms. 123 LayingofIstClassBricks,alongthelengthonbothsideof2Nos33KV/11KVXLPECableinCableTrench(minimum25No.Bricks/MtrperCable)andStoneSlabofsize 450x600x50mm, on top of the each Cable, including providing &filling River Sand inside the Bricks as per Respo Norms. 124 Providing &Laying ofIst Class Bricks, along thelengthonbothsideof01 Nos 33KV/11KV XLPE Cable inCableTrench(minimum 18No. Bricks/Mtr per Cable) andtap ofincluding providing &filling River Sand inside the Bricks as per specification and Respo Norms. 125 Back filling of excavated earth in the cable trench upto the ground level and ramming properly. (Single cable) as per specification and Respo Norms. 126 Laying of 3x300/3x185Sq.mm XLPE Cable in Air & G.I. pipe(Single cable) as per specification and Respo Norms. 127 Laying of 3x300/3x185Sq.mm XLPE Cable in Air & G.I. pipe(Double cable) as per specification and Respo Norms. 128 Laying, spreading, lifting and final sagging of 3 phases of ACSR Dog conductor in accordance with Line chart including binding and fixing of all accessories in 03Nos. Conductor in parallel. Existing tilted Poles to be made straight, if required. as per specification and Respo Norms. 129 Guarding between two poles like single poles, double poles, Tri pole,four poles, etc. to guard L.T., 11KV Line telephone and river crossing, road crossing etc. with G.I.wire No.6SWG and G.I.wire No.8SWG, with providing 16SWG GI wire includingcutting with fabrication and fixing of guarding angle 75x75x6mm, including providing of requried clamps, nut & bolts,eye bolts etc, as perRespo Norms. Guarding clamp made of M.S Flate 65x8mm as per specification and Respo Norms. 130 Branch Chopping of Trees. 131 Providing, Making, fabrication and erection of Terminal Gantry Structure as per specification and Respo Norms. 132 Providing, Making, fabrication and erection of 33 KV Main bus bar complete with structure on Panther Conductor with all PG clamp & connector as per specification and Respo Norms. 133 Red Oxide Paint with painted on pole as per specification and Respo Norms. 134 Aluminium Paint with painted on pole as per specification and Respo Norms. 135 Providing and Fixing of SMC MCCB Distribution board (1 No. I/C & 3No. O/G) for S/S Transformer as per specification and Respo Norms. 136 Providing and Fixing of Copper L-Piece of size 400x50x6 mm for LT bushing Rod of S.S. transformer as per specification and Respo Norms. 137 Providing & Fixing Furniture of Substation as per specification and Respo Norms. 138 Providing & Fixing 1.0 X 2.0 mtr. Size Rubber mat 20 mm. thick as per specification and Respo Norms. 139 Providing & Fixing Protection Board complete as per Respo Norms. 140 Providing & Fixing 4.5 Kg. CO2 Fire Extinguisher, portable type as per specification and Respo Norms. 141 Providing & Fixing 5 Kg. Dry chemical powder fire extinguisher, portable type as per specification and Respo Norms. 142 Providing & FixingFire Buckets (4 nos.) with stand, filled with dry sand as per Respo Norms. 143 Providing & Fixing Outdoor Switchyard Lighting complete in all respect as per Respo Norms. 144 Providing & Fixing 33/11KV S/S Name board (SMC) with stand as per Respo Norms. 145 Providng Lighting in switchyard by providing 04 nos. STP including LEDs as per specification, erection, grouting, wiring etc. & Fixing Lighting of S/S building induding supply & fixing of fitings (As per Specification) as per Respo Norms. 146 Testing and Commissioning of Substation as per Respo Norms. 147 Connection of 33KV Line to 33KV Bay at Primary Substation including energization at load as per Respo Norms. 148 Welding Work Of Old & Dammage of rusted pole at bottom with 3 nos MS Angle 2 mtr Long & Grouting Work as per Respo Norms. 149 Sagging of exsisting 33 kv Line as per Respo Norms. 150 Fixxing, Mounting and Erection of 11 KV Meter Cubical as per Respo Norms. 151 Fixxing, Mounting and Erection of 11 KV CT/PT Cubical Unit as per Respo Norms.

Key Value

Document Fees
INR 3540 /-
EMD
INR 62000.0 /-
Tender Value
INR 61.15 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail