}

Tender For Provision Of Vehicle Repair Shed Under Ge 862 Ews, rajouri-Jammu And Kashmir

Statutory Bodies & Commissions/Committees has published Tender For Provision Of Vehicle Repair Shed Under Ge 862 Ews. Submission Date for this Tender is 06-09-2024. Shed Construction Tenders in rajouri Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

44090976
Corrigendum : Tender For Provision Of Vehicle Repair Shed Under Ge 862 Ews
Open Tender
Indian
Jammu And Kashmir
Rajouri
06-09-2024

Tender Details

Tender For Provision Of Vehicle Repair Shed Under Ge 862 Ews; 1 Sch A Part - I(Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 2 Construction of block of Veh repair shed, complete all as specified and shown in drawings. 3 TotalAmount of Sch A Part - II (Site Clearance) 4 TotalAmount of Sch A -III (Internal Water Supply) 5 TotalAmount of Sch A -IV (Internal Electric Supply) 6 TotalAmount of Sch A -V (Plumbing Work) 7 TotalAmount of Sch A -VI (Area Drainage Work) 8 TotalAmount of Sch A Part -VII (Sewage Disposal Work) 9 TotalAmount of Sch A Part -VIII (Road, Path and Culvert) 10 TotalAmount of Sch A Part -IX (External Water Supply) 11 TotalAmount of Sch A Part -X (External Electric Supply) 12 TotalAmount of Sch A Part -XI (Retaining Wall) 13 TotalAmount of Sch A Part XII (Ramp and Washing Platform Work) 14 Sch A Part - XIII (Misc Items of Work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 15 Construction of 30 user conventional LLDPE septic tank, design to carry sewage and sullage water, excavation in any type of soil PCC (1:4:8) below foundation, vent shaft, connection etc, complete all as specified and directed. 16 Construction of Soakage well (Brick construction) of size 2.4 mtr dia 3.00 mtr deep including excavation & earth work in any type of soil, PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, walls with brick masonry with top ring of M-25 (Design mix) concrete including intercepting chamber and screen chamber and solid brick work in cement mortar 1:4, RCC cover slab in M-25 (Design mix) concrete, filling with brick bats, interconnecting pipe of RCC/DWC complete all as specified and shown on drawing. 17 Supply, installation and testing of hi wall split units indoor/outdoor complete with cordless remote control unit and with in built heating and cooling arrangement and digital inverter twin rotary of capacity 2 TR , complete all as specified and as directed. 18 Supply, installation and testing of hi wall split units indoor/outdoor complete with cordless remote control unit and with in built heating and cooling arrangement and digital inverter twin rotary of capacity 1.5 TR , complete all as specified and as directed. 19 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with out voltage stabilized at 20 volts with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed. 20 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 voltas to 250 voltas with out voltage stabilized at 20 voltas with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed. 21 Submain wiring with 4 sqmm copper conductor single core cable (multistrand) PVC insulated FRLSH (unsheathed), concealed type, drawing in and including PVC conduit 25mm dia, having wall thickness not less than 2mm with sunk cast iron/pressed steel terminal boxes made out of 1.2mm thick sheet including one coat of red oxide primer on internal and external surface covered with 3mm thick hylam brand IS_2036 marked laminated sheet cover (for mounting switches, sockets, regulators etc;) for one light point, controlled by one, one way switch, including 2.5 sqmm PVC insulated FRLSH (unsheathed) copper conductor contunuous earth wire, complete all as specified and directed. 22 Single pole and neutral enclosure with two pin and earth plug and socket socket with 20 Amp MCB, 240 Volts with sheet metal enclosure, IP-66, complete all as specified and directed. 23 FRP looping box of size (325x320x150)mm with connector and comprising of MCB SP 6 Amps, ISI marked, 240V complete with and including providing GI clamps , nuts etc suitable for fixing on PCC pole/wall/steel tubular pole etc complete all as specified and directd.Make: National/Sintex. 24 GI bracket pipe of size 40mm dia medium grade of 1.2mtr long, bent to shape,suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket pipe shall be fixed on wall /pole, steel/PCC surfaces by providing suitable MS iron 25x4 mm clamps 2 Nos of length as required at site to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts & washers, complete all as specified and directed. 25 Copper conductor cable,1.5 Sqmm, 3 corePVC indulated, sheathed, flexible, multistranded , ISI marked, 1100 Volts grade and including connection and testing including removing old unserviceable item, complete all as specified and directed. 26 Supply, installation, testing and commissioning of totally encloused LT electric panel outdoor type (IP-55)fabicrated out of 3.15mm thick CRCA, CPRI approved sheet dust and vermin proof powder coated double door type independent cabin including locking attangement for each ACB/MCCB, bus bar chamber enclosed complete suitable for operating on 415 volt 50 Hz AC supply internally wired with copper conductor/strip of adequate size from main incoming MCCB to bus bar and bus bar to outgoung MCCB /MCCBs having legs 45cm made out of 65x65x6mm angle iron grouted on brick masonary platform upto 30cm. Brick masonary plarform should be 60cm above the ground level, comprising the following:-(a) MCCB 250 Amps, FP, 36 KA, 415 volts, 50Hz -01 No (Incoming)(b) MCCB 125 Amps, FP, 16 KA, 415 volts 50Hz -02 Nos (Outcoming)(c) MCCB 63 Amps, FP, 10 KA, 415 volts 50Hz -02 Nos(d) Digital voltmeter, with VSS -01 set , Digital, Ammeter, with CTs, & ASS-01 set (e) LED phase indication lamps RYB -01 set (f) Aluminium bus bar TPN 400 Amps rating -01 set 27 Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, mediumgrade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion, complete all as specified and as directed. 28 Point wiring complete with 1.5 sqmm PVC insulated, FRLSHtype, unsheathed, multistranded, flexible copper conductor cable 1.5 Sqmm 1100 volts grade, drawn through and including PVC conduit, medium grade of size 25mm or above as required at site with all accessories such as tee, corner, overlaping connector etc; on surface walls, roots and ceiling etc; including concealed MS box factory made of suitable size fabricated out of 1.6mm thick MS sheet and frame suitable for fixing and including bakelite hylam sheet 3mm thick fixed flush with wall surface by means of stainless steel cadmium plated screws and cup washers suitable for mounting switches, socket, fan regulators etc; and including 1.5 Sqmm PVC insulated, multistranded, unsheathed (greed colour), FRLSH type single core, copper conductor cable as earth continuity conductor and connecting to common earth dolly for one light point controlled by one switch, complete all as specified and directed 29 All as per Srl Item No. 27 hereinbefore but for one 3 pin 6 amps socket outlet point controlled by one 6 amps switch on independent board. 30 All as per Srl Item No. 27 hereinbefore but for one 3 pin 6 amps socket point controlled by one 6 amps switch on same board. 31 All as per Srl item No.27 hereinbefore, but point wiring with 2.5 sqmm copper conductor cable and earth conductor of size 2.5 sqmm copper conductor cablefor one 6 pin 16/6 amps socket outlet point controlled by one 16 amps switchon independent board complete all as specified and directed. 32 Point wiring complete with 1.5 sqmm PVC insulated, FRLSHtype, unsheathed, multistranded, flexible copper conductor cable 1.5 Sqmm 1100 volts grade drawn through and including stove enamelled steel conduit of size 20mm or above as required at site with all accessories such as tee, corner, overlaping connector etc; on surface walls, roots and ceiling etc; for mounting flame proof fitting etc; and including 1.5 Sqmm PVC insulated, multistranded, unsheathed (greed colour), FRLSH type single core, copper conductor cable as earth continuity conductor and connecting to common earth dolly for flame proof fittings point controlled by one switch, complete all as specified and directed 33 LED 70W high bay light energy saving, environment friendly & robust IP 65 procted LED midway with PDC housing suitable for ceiling (surface /suspended) mount & available wide beam optics, including connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core, complete all as specified and directed. 34 LED lights fitting 1x20W, 220V. AC type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core, complete all as specified and directed. 35 CRCA box type LED lights fitting including 2x20W LED tybe polycorbonated, 220V. AC type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core, complete all as specified and directed. 36 Factory made sheet metal enclosure, double door, 415 volts, AC, TPN vertical distrubution board 12 way painted with epoxy based powder coated suitable for mounting MCCB as incomer of rating upto 250 Amps, FP, rating upto 36 KA and MCB SP/TP as outgoing and complete with including 200 Amps rated copper busbar, neutral bar, each bar, connecting cable links with and including top bottom removeable gland plate with IP 43 protection, fixed in repair, completeall as specified and directed. Note:- MCCB/MCBs will be measured separately. 37 MCBTP 40 Amps, 10 KA, 415 Volts C series complete all as specified and directed. 38 MCCBFP, 250 Amps, 36 KA, 415 Volts complete all as specified and directed. 39 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade (ISI marked) 20mm dia including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6.0 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed. 40 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 2.5 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 20mm dia including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 2.5 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed. 41 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 20mm dia including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed. 42 Sub main wiring with four run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 20mm dia including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed. 43 Earthing complete with steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron earth wire 4.0mmdia by means of bolts, nuts, check nuts and washers of galvanised iron and steel earthwire protected by provision of GI Medium grade pipe 15 mm bore including provision of concrete pit made from PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 17mmthick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x3mm with lugs 02 No and with 6 mm dia MS bar handle made to shape GI medium grade 20 mm bore pipe for watering perforated at bottom, 1.75 metere long placed on top edge of earth plate, common salt and charcoal fittings, test point made out of 17 mm x 8 mm FI with fixing arrangement, funnel wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance notexceeding 50m all as per electrical plate No 5 of SSR Part- I connected to earth test point complete all as specified and directed or indicated including testing on completion. 44 Supply, installation,connecting, commissioningand testing transformerof capacity 160 KVAstep down 11/0.433KV, outdoor type with totally enclosed cable boxes at HV & LV sides with suitable SS cable glands, double copper wound3 phase 4 wire 50c/s oil immersed naturally cooled with externally cooling tube, core type deltaconnected onprimart(HV) 11kv side and star connected on secondary(LV) 433V side having tapping ±2.5%,±5%,±7.5% and to change by means of hand operating off load tap changing gear including first filling of oil of dielectric strength not less than 45KV with all fittings such as silica gel blue in color in crystal form filled in breather pot, drain out valve, (oil tank) conservator tank of suitable capacity with level indicator,exhaust vent, temperature guage and accessories and all as per IS1180:2014 with all latest amendments complete. The transformer will comprise of oil level indicator for breather tank, lifting eye circular bolts 2 Nos, fixed on top cover plate, bottom wheels 4 Nos skid type under base plate mounted on SMC-100 channel 2 Nos not less than 3.0 meter long upto transformer plinth length/width complete all as specified and directed. 45 Ceiling fan complete with three blades, down rod, electronic regulator and accessories, 230V, 1400mm sweep with squirrel cage induction motor complete all as specified and directed . 46 Air circulator fan, 230 volts, single phase, oscilating 600mm sweep suitable for wall mounting, complete all as specified and directed 47 Deduction to be made from BOQfor Sch A Part - XIV (Schedule of credit) Amount of Rs.2,500.00 during AOC.Note: Tenderers shall not quote for this schedule.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-08-2024 Due Date Extended for tenders closing on 10-08-2024. Admin Corrigendum Date Extend 06-09-2024

Key Value

Document Fees
INR 2000 /-
EMD
INR 478000.0 /-
Tender Value
INR 4.03 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail