| 1 | Sch \"A\" Part - I(Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \"Rs. 0.00\" under col.5 signifies this fact only. |
| 2 | Construction of Car garage block for one car including open platform, ramp and draft wall, complete all as shown on drawings and as specified. |
| 3 | TotalAmount of Sch \"A\" Part - II (Path and Hardstanding Work) |
| 4 | TotalAmount of Sch \"A\" Part - III (Internal Supply Work) |
| 5 | TotalAmount of Sch \"A\" Part -IV (External ElectrIc Supply Work) |
| 6 | TotalAmount of Sch \"A\" Part -V (Addition/ Alteration and Repair Work) |
| 7 | Sch \"A\" Part - VI (Misc Items of Work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \"Rs. 0.00\" under col.5 signifies this fact only. |
| 8 | Water proofing treatment to sunken portion of WCs bathroometc by applying cement slurrey mixed with Acrylic based polymer modified cementitious composite compound(a) First layer of slurry cement @ 0.488 kg/ Sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/Sqm .The layer will be allowed to air cure for 4 hrs. (b) Second layer of slurry of cement @ 0.242 kg /Sqm mixed with Acrylic based polymer modifiedd cementitious composite compound @ 0.126 Kg/Sqm . The layer will be allowed to air cure for 4 hrs. |
| 9 | Grubbing up bushes, tree trunk portion not exceeding 30cm girth including cutting of trees/bushes grown in over wall and roofs digging out roofs and making good disturbed area of wall/roofs with PCC 1:3:6 type C-1using 20mm graded crushed stone aggregate, complete all as specified and as directed. |
| 10 | Repairing RCC projection chajjas, roof, facia etc. by necessary preparation, scraping, cutting, chiselling derustingand cleaning exposed reinforcement surfaces of damaged, loose RCC surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregates and including reinforcement with MS welded mesh of weight exc 2Kg per sqm but n.exc 3Kg/sqm with or without facia and rendering with 5mm thick cement mortar 1:3 finished even and smooth without using extra cement and work in patches area n.exc 5 Sqm and thickness RCC member n.exc 70mm including necessary formwork and applying two coats of finishes to match with the existing surfaces at any height complete. |
| 11 | Brass chromium plated wall mixer with provision of shower for mixing hot and cold water 3 in 1, fancy type, with long shank and cupscrewed down high pressurescrewed both ends for iron pipe or for union 15mm bore, fixed in repair, complete all as specified and as directed. |
| 12 | Brass chromium plated mixer as in WHB mixer 2 in 1, cast copper alloy, with capstan head, screwed down high pressure with or without lathered hot or cold with long screwed shanks and fly nuts screwed for iron pipe 15mm bore, fixed in repair, complete all as specified anddirected. |
| 13 | Sinks made of stainless steel (304 Gde) mat finish 1mm thick, double bowl,medium sizewith plugs, washers and wastes, couplingincluding bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, fixed in repair,complete all as specified and as directed. |
| 14 | Stainless steel shelf450mm longand 100mm wide fixedover WHB of approvedquality as per sample held in GE Office, complete all as specified and as directed. |
| 15 | PVC bath room cabinet of size 535mmx483mmx110mm with mirror,complete all as specified and as directed. |
| 16 | CP grating 150mm dia with centre hole, complete all as specified anddirected. |
| 17 | Modular Kitchen System suitable for Captain\"s accomodation having upper cabinets and lower cabinets which includes all utility accessories such as cutlery organisers, cutlery organiseser trolys, pull out baskets, bottles pull outs, tall units, corner units, under sink assessories etc complete. (i) Upper cabinet system shall have minuimum 4.00 sqmarea with AluminumComposite Panel (ACP) with Aluminium sections 40mm x 40mm, window sections 60mm x 32mm, Aluminum tube 25mm x 40mm , 5mm thick designer glass, 8mm thick glass shelves, aluminum angles 25mm x 25 mm, rubber 4mm, aluminum beading clips, stainless steel handles and hinges, catches steel magnetic type etc complete |
| 18 | (ii) Lower cabinet system shall have minimum 5.60 sqm area with aluminum composite panel (ACP) sheet 4mm thick with aluminum section 40mm x 40mm, window sections 60mm x 32mm,hydraulic channel 500mm by 25 mm. 5mm thick designer glass, 8mm thick glass shelves, aluminum angels 25mm x 25mm , rubber 04mm , aluminum bidding clips, catches hinges etc complete (iii) Colour of ACP sheet , make and design and layout of modular kitchen will be approved by GE. ACP sheet make : Viva, Euroboard, Alstone, Alucobond, Alstrong |
| 19 | Modular Kitchen System suitable for Major\"s accomodation having upper cabinets and lower cabinets which includes all utility accessories such as cutlery organisers, cutlery organiseser trolys, pull out baskets, bottles pull outs, tall units, corner units, under sink assessories etc complete. (i) Upper cabinet system shall have minuimum 5.60 sqmarea with AluminumComposite Panel (ACP) with Aluminium sections 40mm x 40mm,window sections 60mm x 32mm, Aluminum tube 25mm x 40mm , 5mm thick designer glass, 8mm thick glass shelves, aluminum angles 25mm x 25 mm, rubber 4mm, aluminum beading clips, stainless steel handles and hinges, catches steel magnetic type etc complete |
| 20 | (ii) Lower cabinet system shall have minimum 8.60sqm area with aluminum composite panel (ACP) sheet 4mm thick with aluminum section 40mm x 40mm, window sections 60mm x 32mm,hydraulic channel 500mm by 25 mm. 5mm thick designer glass , 8mm thick glass shelves, aluminum angels 25mm x 25mm , rubber 04mm , aluminum bidding clips, catches hinges etc complete |
| 21 | (iii) Colour of ACP sheet , make and design and layout of modular kitchen will be approved by GE. Make:- ACP sheet make : Viva, Euroboard, Alstone, Alucobond, Alstrongheet make : Viva, Euroboard, Alstone, Alucobond, Alstrong |
| 22 | One pieces Vitreous China floor mounted opentrap close couple EWC with S trap Cistren,twin flush fitting ,soft close seat cover white (including fixing bolts, flush pipe) and mild steel chromium plated or aluminised hinging device and making good to dismantled/ damaged floor in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), fixing in repair, complete all as specified. |
| 23 | Brass Corehealth faucet with suitabelbrinded Hoseflaxible pipe, complete all as specified and directed. |
| 24 | Chromium plated Jet spray with plate and suitabelbrinded Hoseflaxible pipe, fixed in repair, complete all as specified and directed. |
| 25 | Brass chromium plated tubular towel rack3 hooks, 60cm long between flanges complete. |
| 26 | 32mm dia waste pipe for WHB, complete all as specified and directed. |
| 27 | Factory made box type steel window (Double Shutter),using ERW hollow \"P\" section comprising double frame for and including gauged and glazed Skeleton shutter jointed internally with flat iron 40mm x 4mm complete including grill of 8mm square bars, fixed horizontally @ 10cm c/c, hinges, handle, tower bolts, stops, lugs etc. all as shown on drawing No. CEUZ/TD-1304 sheet 1/3 to 3/3 as applicable complete all as specified and as directed. |
| 28 | Cupboard shutter 20mm thick (style) factory made pannel PVC incl chowkat framemade out of m.s tubes 19 gauge for top and bottom rails m.s frame shall be covered with heated moulded plain colour PVC (c)channel having a PVC sheet strip of 10mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail and bottom rail on either side 10mm (5mmx2) thick of 20mm and 20mm cross PVC sheet and as gap insert for top and bottom rail. Pannelling for plain colour PVC sheet to be fitted in the m.s frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying fixing in the frame at site as per specification and drawing as in repairs. |
| 29 | Epoxy powder coated with fixing brackets pelmet rods of mild steel 20 mm with and including pair of fancy type finnals fixed as in repair, complete all as specified and directed. |
| 30 | Dismantling of old/ damaged existing roof treatment with concrete and cleaning all waste and dirt by wire mesh, picking, sweeping and washing down with water to remove dust, etc, and removal of all material out side the cantt. area, complete all as specified and as directed |
| 31 | Material and labour for water proof treatment roof top with 5 course APP membrane treatment will be applied as under:- (a) applying a coat of bituminious primer confirming to IS - 3344 @ 0.40kg/Sqm on the prepared surface.(b) after the primed surface has dried, apply a coat of hot blown 85/25 penetration grade blown bitumen or equivalent viscosity grade blown bitumen (Penetration of bitumen when tested as per IS 1203 will not be more than 40) conforming to IS 702 @1.20 kg/sqm of the surface. (c) provide minimum 3mm thick APP (Atactic polypropylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film. Minimum weight of membrane shall be 3kg /Sqm . Other proporties of APP modified water proofing membrane will be as laid down in MES SSR -I Part. APP membrane will be laid minimum end lap of 150 mm and side lap of 75 mm bonded with hot blown bitumen. |
| 32 | (d) Over the APP membrane apply semi hot blown 85/25 penetration grade bitumen or equivalent viscosity grade blown bitumen (Penetration of bitumen when tested as per IS 1203 will not be more than 40) / conforming to IS 702 @ 1.20 kg /Sqm and blinded with fine sand in dry condition @ 0.50 Kg/Sqm dusted over the bitumen coat and applying two coats of aluminium paint as per manufacture\"s instruction, complete all as specified and as directed |
| 33 | Taking down unserviceable sub main wiring concealed type ofany description along with PVC conduit including conduit accessories and made good the disturbed surfaces where ever necessary complete all as specified. |
| 34 | Taking downunserviceable sheet metal enclosure concealed type withMCBs including making good the disturbed suface complete all as specified. |
| 35 | Taking down Exhaust fan, dismantling blades, depositeto MES store yard complete all as specified and directed. |
| 36 | Disconnection carefully and taking down of old Energy Meter and deposite to MES store complete all as specified. |
| 37 | Disconnecting, carefully old Electric water heater of capacity 25/50 Ltrs including PVC Connection and handing over to AGE E/M store yard, refixing the same on the same position after completion of the wall repair worksincluding connection, cleaning of out side surface of the Geyser, testing after completion complete. including making good the surface complete all as directed. |
| 38 | Taking down of oldunserviceable GI bracket set fixed on wall including making good the suface complete all as specified and directed. |
| 39 | Point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade (MMS) andincluding cutting, chasing work at any height and all accessories are in concealedinwalls /roofs/floors / ceiling etc. flush mountingMS box with top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved colouresandincluding 1.5 SqmmPVCinsulatedmultistrandedFRLSHtype |
| 40 | unsheathed (Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:-(Note:- Allnecessary accessories such asmodular box,top cover, plate, blank plate,MS box,screws,washers and all modular electrical fixtures are to be used same make/brand onlyand modular box,top cover plate, MS box shall be measured and paid seperately under relevant items) |
| 41 | One light point/fan point/ exhaust fan point/ bell point controlled by one switch. |
| 42 | One 3 pin 5 amps socket point controlled by one 6 amps switch on independent board . |
| 43 | One 3 pin 5 amps socket point controlled by one 6 amps switch on same board . |
| 44 | One light point controlled by two 2 way switches. |
| 45 | All as per Srl item No.34 hereinbefore, but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm for One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switchon independent board complete all as specified and directed. |
| 46 | LED bulb 9 watts, 240 Volts, 50Hzpin type andincluding removing old unserviceable fittings, complete all as specified and directed. |
| 47 | Modular LED Indicator Lamp fixing on modular switch board 240V, AC, 50Hz suitable for 1/2 module ISI marked, including connecting with suitable length of1.5sqmm PVC insulated copper conductor complete all as specified and directed. Make : Anchor Roma Cat No 21180R or equivallent |
| 48 | LED lights fitting 1x 20W, 4\" long 220V, AC Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 49 | LED lights fitting 1x 10W, 2\" long 220V, AC Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 50 | Decorative wall light fixture Globe type including 9 W LED Lamp made up of polycarbonate complete all as specified and directed. Make- Havells Cat No-LHFOFUE1TZ1W012 or equivallent. |
| 51 | Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, 230V, 50 Hz, Copper winding of sweep 200mm including making suitable hole on brick wall and making good the hole with cement plaster and provision of cable 3 core of 0 .5 sqmmfrom ceiling rose to fan complete all as specified and directed. |
| 52 | Vertical type sheet metal enclosure DB TPN 6 way double door made powder coated out of CRCA mild steel sheet 1.6 mm thick 415 volts 200 amps rated fitted bus bar dust and vermin proof suitable for incorporation of MCCB as incomer and MCBs as out going duly concealed on wall and making good the disturbed surface including MCCB, four pole, 125 Amps, 415 volts, 50 Hz,16KA complete all as specified and directed. |
| 53 | Vertical load line sheet metal enclosure DB TPN 6 way double door made powder coated out of CRCA mild steel sheet 1.6 mm thick 415 volts 200 amps rated fitted bus bar dust and vermin proof suitable for incorporation of MCCB as incomer and MCBs as out going duly concealed on wall and making good to disturbed surface including MCCB, four pole, 160/163 Amps, 415 volts, 50 Hz,16KA complete all as specified and directed. |
| 54 | Sub main wiring complete with 2 run of 6 Sqmm single core copper conductor (ISI marked) cable1100 volts grade, FRLSH type, PVC insulated, unsheathed, flexible, multi strandedcolour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 6 Sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and chasing and complete all as specified and directed.Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. |
| 55 | All as per item ser No 44 above but 2 run of 4 Sqmm single core and one run of 4 Sqmm single core as earth wire for geyser. |
| 56 | All as per item ser No 44 above but 4 run of 10 Sqmm single core and one run of 10 Sqmm single core complete. |
| 57 | Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM, RCC cover 1:2:4 type B1 of size 45X45X6CM, excavation/earth work in any type of soil and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old unserviceable earthing items, completeall as specified and directed. |
| 58 | GI bracket pipe of size 40 mm dia, medium grade of 1.0 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixedon wall surfaces and including suitable fabricate MS flat ironclamps of 25X6 mm thick: 02 Nossuitable for fixing any places with nuts,bolts & washers including grouting on wall etc, complete all as specified and directed. |
| 59 | Wall mounted fan 400mm sweep along with speed control complete with all accessories including mounting on wall with necessary arrangemets complete all as specified and directed. |
| 60 | Multi meter box for housing of Energy meter including provision of door with hinges and locking arrangement of oute size 1040mmx730mmx290mm concealed on wall including cutting on wall and making good the disturbed sufaces with cement plaster including taking down of old unserviceable meter box complete all as specified and directed. |
| 61 | Deduction to be made from BOQfor Sch \"A\" Part - VII (Schedule of credit) Amount of Rs. 2,38,590.00 during AOC.Note: Tenderers shall not quote for this schedule. |